58277508 Nemo Outdoor Scanner Guide

105
Nemo Outdoor Scanner User Guide Version 5.71.00
  • date post

    09-Feb-2016
  • Category

    Documents

  • view

    156
  • download

    27

Transcript of 58277508 Nemo Outdoor Scanner Guide

Page 1: 58277508 Nemo Outdoor Scanner Guide

Nemo Outdoor Scanner User Guide

Version 5.71.00

Page 2: 58277508 Nemo Outdoor Scanner Guide

SCANNER USER GUIDE 3 

CONNECTING DEVICES 3 

Connecting Nemo FSR1 Scanner 3 

Connecting Anritsu Scanners 6 Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer scanner 12 

Connecting the DRT Wimax 4301A+ Scanner 16 

Connecting the PCTEL LX CDMA/EVDO/GSM/WCDMA Scanner 18 

Connecting PCTEL EX scanners 20 

Connecting the PCTEL LX GSM/WCDMA Dual-Mode Scanner 24 

Connecting the PCTEL MX GSM/WCDMA Scanner 27 

Connecting PCTEL PCT Scanners 29 

Connecting the Rohde & Schwarz TSMQ/TSML Scanner 32 

Connecting the Rohde & Schwarz TSMW Scanner 36 System Priority Order with R&S TSMW Scanners 38 

STARTING DEVICES 40 

Starting Nemo FSR1 Scanner 40 

Starting Anritsu Scanners 41 

Starting DRT Scanners 43 

Starting PCTEL Scanners 44 

Starting Rohde & Schwarz Scanners 50 

STARTING MEASUREMENT 51 

Nemo FSR1 Scanner 51 GSM+UMTS Scanning 51 TOP-N Pilot Scanning - UMTS 52 

Anritsu Scanners 55 GSM+UMTS Scanning 55 TOP-N Pilot Scanning - UMTS 57 Pilot Scrambling Code Scanning - Anritsu Scanners 63 DVB-H Scanning 65 Spectrum Analyzer Measurements 66 

PCTEL Scanners 69 Frequency Scanning – PCTEL GSM/UMTS Scanners69 Frequency Scanning – PCTEL EX LTE Scanner 71 Frequency Scanning – PCT GSM Scanner 73 Frequency Scanning – PCTEL EVDO Scanners 75 TOP-N Pilot Scanning PCTEL - UMTS 77 TOP-N Pilot Scanning - PCTEL EX/LX, EVDO 79 Spectrum Scanning - PCTEL EX 81 LTE OFDM Scanning – PCTEL EX LTE 85 Pilot Scrambling Code Scanning - PCTEL LX 88 

DRT Scanners 90 Frequency Scanning 90 Pilot Scanning 92 

Rohde & Schwarz TSMQ/TSML/TSMW Scanner 94 Frequency Scanning - Rohde & Schwarz Scanner, GSM 94 TOP-N Pilot Scanning - Rohde & Schwarz Scanners, UMTS 96 TOP-N Pilot Scanning - Rohde & Schwarz Scanner, CDMA/EVDO 98 TOP-N Pilot Scanning - Rohde & Schwarz TSMW, LTE100 Spectrum Scanning - Rohde & Schwarz Scanners 102 

TROUBLESHOOTING 105 

Page 3: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 3

SCANNER USER GUIDE

CONNECTING DEVICES

Connecting Nemo FSR1 Scanner

Nemo FSR1 scanner is powered by 10 to 16 VDC. AC operation for the standalone

receiver is achieved by using the optional AC power supply. The AC power supply is

designed to work with 100 - 240VAC 50/60Hz. For other voltages or line frequencies

contact Anite for the correct supply.

The standard AC supply is rated at 130 Watts. Actual power requirements will vary

depending number of downconverters installed and the receiver tasking. The

maximum power requirement of the scanner is 50 Watts.

DC operation for the standalone receiver can be achieved by connection to a vehicle

12-volt system. The following table is provided to budget the system current

requirements for various configurations.

Platform configuration/Module 12 VDC current requirement

Basic system w/ single downconverter 3.0 A

Two downconverter system 3.6 A

The estimates given for the scanner assume maximum utilization of the processing

capabilities.

Page 4: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 4

Connecting the Nemo FSR1:

1. Connect an antenna cable to scanner RF input. If you are measuring with two

downconverters, connect an antenna in both RF inputs (see picture below).

2. Connect Ethernet cable(s) to the scanner Ethernet port(s) and to the Nemo

Outdoor laptop.

3. Go to Control Panel | Network and Internet | Network and Sharing Center.

Click on Change adapter settings.

RF input RF input

GPS connector Status LEDs Ethernet ports Serial port

Page 5: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 5

4. Right-click on Local Area Connection and select Properties. In the Local Area

Connection Properties dialog, select Internet Protocol Version 4 (TCP/IPv4)

and click Properties.

5. Select Use the following IP address and type in the IP address of the scanner in

the IP address field. Click OK and Close.

Page 6: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 6

6. Connect the power cable to the scanner and to a power source. Switch power on.

7. The default address and name settings of the scanner are generally suitable for

most users. There is no need to configure these settings when using the Nemo

FSR1 scanner with Nemo Outdoor.

8. The status LEDs at the front panel display how the scanner is functioning.

LED Name LED Color Description RxA Green Receiver A enabled

Amber Receiver A disabled i.e. EEPROM not readable RxB Green Receiver B enabled

Amber Receiver B disabled i.e. EEPROM not readable Status Green GPS Locked

Amber GPS Unlocked Active Green Ethernet link connected

Red Ethernet link disconnected All LEDs Amber If all four LEDs are amber, the bootloader is

running and the module needs to be reloaded

Connecting Anritsu Scanners

These instructions apply to all except Anritsu MS2721B DVB-H Analyzer

scanner.

1. Connect the antenna cable to scanner RF Input. If you are measuring with a dual-

mode scanner that supports both GSM and WCDMA, use the RF1 input (see

picture). RF2 input only supports WCDMA scanning.

Fuse

Power connector Power switch

Fans

Page 7: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 7

2. Connect the battery cable to the battery and to a power source.

3. The Battery led of the scanner should turn green.

The following steps apply to Anritsu ML8720B and ML8720C scanners. If you are

measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see step 12.

Page 8: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 8

4. Connect the null modem cable to the scanner COM port that can be found below

the power switch.

5. Connect the null modem to one of the PC COM ports

6. Turn the power on in the scanner. The Power led should light up.

7. The scanner should now start, wait until the scanner has started

8. Press the Menu button in the scanner.

9. Use the arrow keys and the Sel button to select Interface and Behavior.

10. Check that the settings are as follows. If not, change them using the arrow keys

and the Sel button (note that the selected item will be underlined as soon as you

use the arrow buttons to switch to another line). To exit the dialog box without

saving, press the F4 button (Cancel). To exit the dialog box and save the modified

settings, press the F5 button (OK).

COM1 Protocol: Direct

COM1 Baud Rate: 38400 or 57600 or 115200

COM1 Stop Bit(s): 1

COM1 Data Length: 8

COM1 Parity: None

The baud rate 115200 is the fastest option.

Note! Memorize the baud rate. It is needed when starting the device.

Page 9: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 9

11. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see

the following steps.

12. Insert the Anritsu installation CD in your PC.

13. Connect the USB cable to the scanner USB port found in the front panel and to

the PC.

14. Switch the scanner on.

15. The New Hardware Wizard will start automatically. Select the No, not this time

option and click Next.

16. Select the Install the software automatically option and click Next.

Page 10: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 10

17. If a warning message appears, click Continue Anyway. The installation will start.

Please wait while the New Hardware Wizard installs the software. When the

installation is complete, click Finish.

18. To check that the installation was successful, go to Device Manager (Start |

Settings | Control Panel | System | Hardware | Device Manager). Expand the

Universal Serial Bus controllers item. Area Scanner should be on the list.

Page 11: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 11

19. Double-click on Area Scanner. Check that the Device Status field displays This

device is working properly. Exit the dialog by clicking OK.

Page 12: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 12

Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer scanner

Installing the driver:

Please follow the following steps to install the NI-VISA 4.0 driver.

1. To install the driver the user must have administrative rights to its PC, and the

Take ownership of files or other objects policy has to be enabled for this user

on this PC.

2. Copy the executable file visa400full.exe to your local drive before installing the

driver, and run the installation from the hard drive.

3. Double-click on the file and unzip the contents to your hard-drive. This may take a

couple of minutes.

4. The installation starts automatically.

5. Click Next>> on the welcome page.

Page 13: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 13

6. Select the destination folder for the driver and click Next>>.

7. Click Next>> in the Features dialog.

8. Select I accept the License Agreement(s) in the following page and click

Next>>.

9. Click Next>> in the following dialog and wait for the installation to finish, and

Finish in the Installation Complete dialog. Note that you may need to restart your

computer for the installation to take effect.

Page 14: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 14

10.Connect the scanner with your PC through a network cable. Insert one end of the

network cable in the network cable connector in the scanner, and the other end to

the network cable connector in your PC.

11.Next, you need to make some changes to your PC’s network card properties. Go

to Start | Control Panel | Network Connections, and right-click on Local Area

Connection, and select Properties. In the Local Area Connection Properties

dialog, select Internet Protocol (TCP/IP) and click on Properties. Select Use

the following IP address. You need to type in an IP address out of the range

192.168.0.11 - 192.168.0.14, as those addresses are reserved for the scanner.

Type in, for example, 192.168.0.10. Next, type 255.255.0.0 in the Subnet mask

field. Click OK and Close to exit the dialogs.

12. Next, start the scanner by pressing on the green On/Off button.

13. Press on Shift and then System (8) button on the scanner.

Page 15: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 15

14. On the menu to the right of the screen, select System Options | Ethernet

Config by using the grey buttons next to the screen.

15. Select the Set the IP Address Manually using the following Settings by

pressing the top-most grey button immediately under the Esc button.

16. Type in the same IP address for both IP and Gateway from those reserved for

the scanner (192.168.0.11 - 192.168.0.14). Here the selected IP address will be

192.168.0.14. You can move to different directions on the screen through the grey

buttons. If the Subnet field is not automatically filled when filling the IP and

Gateway fields, you can use, for example, 255.255.255.255 for it. Press Enter

and restart the device by clicking twice on the On/Off button.

17. When the scanner has restarted, start Nemo Outdoor. Go to Measurement | Add

device | Scanner, and select Anritsu MS2721B DVB-H or Anritsu MS2721B

Spectrum Analyzer. Click Next.

18.In the Scanner Properties dialog that appears, select one of Anritsu LAN 1-4

ports depending on which IP address you entered on the device. If you entered

192.168.0.11, select Anritsu LAN 1, if you selected 192.168.0.12, select Anritsu

LAN 2, etc. Since 192.168.0.14 was selected earlier, the Anritsu LAN 4 port will

be used here.

Note that the Baud rate, Antenna gain and Cable loss fields do not affect the

scanner, so they can be left as they are.

19. Click OK. See page 65 for more information on how to perform DVB-H

measurements. See page 65 for instructions regarding settings for the Spectrum

Analyzer.

Page 16: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 16

Connecting the DRT Wimax 4301A+ Scanner

Note! The DRT 4301A+ scanner does NOT have an On/OFF switch. The unit is

powered by connecting the power cable and powered off by disconnecting the

power cable. When connecting cables to the unit, the power cable should be

the last one connected and the first one disconnected.

1. Insert one end of the RJ-45 cable in the DATA jack in the scanner, and connect

the other end with the PC.

2. Insert the power cable in the connector marked DC IN.

3. Plug the antenna cable in the FR IN B port in your DRT scanner.

Note that you can only select one of the antennas, 2300/2500MHz or the

3500MHz antenna, and connect it with the scanner. You must select between

the antennas at this point.

4. Connect the scanner’s GPS antenna cable to the scanner’s GPS port, and place

the GPS antenna on a visible spot.

5. Go to Start | Control Panel | Network Connections on your PC.

6. Right-click on Local Area Connection and select Properties.

7. In the Local Area Connection Properties dialog, select Internet Protocol

(TCP/IP) | Properties.

Page 17: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 17

8. In the General tab, select Use the following IP address, and type 192.168.5.1 in

the IP address field, and 255.255.255.0 in the Subnet mask field.

9. Click OK and Close to exit the dialogs.

10. Now connect the scanner’s power cable. The scanner is now on. A green light will

turn on in the scanner.

11. Start Nemo Outdoor. Go to Measurement | Add New Device | Scanner. Select

DRT WIMAX 2300, DRT WIMAX 2500 or DRT WIMAX 3500 depending on which

band you choose to measure at the time.

Page 18: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 18

12. In the Scanner Properties dialog, select DRT LAN in the Port drop-down menu.

Note that the Baud rate, Antenna gain and Cable loss fields do not affect the

scanner, so they can be left as they are.

13. Click OK to exit the dialog.

14. Go to page 90 for more information on conducting WIMAX measurements with

the DRT scanner.

Connecting the PCTEL LX CDMA/EVDO/GSM/WCDMA Scanner

1. Connect the antenna cable to the scanner RF Input.

Page 19: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 19

2. Connect the scanner GPS antenna cable to the scanner GPS input (above RF

Input).

3. Connect the scanner power cable to the scanner serial port (Data).

4. The scanner cable is split into a serial cable connector and a power cable

connector. Connect the serial cable to one of the COM ports in the PC. Connect

the scanner power cable to a cigarette lighter in the car.

5. When connecting the scanner power cable, check the Power led:

If the led is first orange for a while and then turns green, the scanner is

working properly and using a baud rate of 38400

If the led blinks orange and black for a while and then turns green, the

scanner is working properly and using baud rate of 115200

Page 20: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 20

If the led is red, the scanner is not working properly. Switch the power off and

on again. If this occurs after usage, the device may be overheated. Let it cool

down for a while.

Note! Memorize the baud rate. It is needed when starting the device.

Connecting External GPS to PCTEL LX EVDO/GSM/WCDMA Scanner:

Note that you cannot use both the integrated and an external GPS receiver at

the same time.

1. Connect the GPS serial cable to a PC serial port.

If there is only one port in the PC by default, this port should be reserved for

the scanner. In this case connect the GPS to the PCMCIA serial port adapter.

2. Connect the GPS power cable to a cigarette lighter.

Connecting PCTEL EX scanners

Installing the SeeGull EX VCP Device Driver

Please follow the following steps to install the VCP device driver.

1. To install the driver the user must have administrative rights to its PC, and the

Take ownership of files or other objects policy has to be enabled for this user

on this PC.

2. Copy the folder /SeeGull EX VCP driver_v.2.0.0.46B to your local drive before

installing the driver, and run the installation from the hard drive.

Right click on the folder and select Properties.

Uncheck the Read-only attributes and click OK.

Select Apply changes to this folder, subfolder and files as below

and click OK.

3. Double-click on the SeeGull EX VCP Device Driver.msi installer file to start the

driver installation.

Page 21: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 21

4. Click Next in the SeeGull Welcome window that appears.

5. Select the destination folder for the driver in the Destination Folder window, and

Click Next, and click Install.

6. Click Finish in the InstallationShield Wizard Completed window to exit the wizard.

7. Remove the yellow plastic caps from the antenna, power and GPS connectors in

the front panel.

Page 22: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 22

8. Connect the power cable to the Power connector in the front panel. Connect the

other end of the cable to a cigarette lighter socket. The SYS indicator in the front

panel will light up.

9. Connect the antenna cables. It does not matter which antenna cable goes to

which RF connector.

Page 23: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 23

10. Connect the GPS antenna to the connector marked GPS.

11. Connect the USB data cable to the USB port in the front panel. Connect the other

end of the USB data cable to your PC.

12. Windows will automatically detect the device.

Page 24: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 24

Connecting the PCTEL LX GSM/WCDMA Dual-Mode Scanner

1. Remove the yellow plastic caps from the antenna and GPS connectors in the

front panel.

2. Connect the power cable to the Power and Data connector in the front panel.

Connect the other end to a USB port on your computer and to a power source.

The green Power indicator in the scanner front panel will light up.

Page 25: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 25

3. Connect the antenna cables. Note that the antenna cables and the connectors in

the scanner front panel are color coded. The OP042 cable marked with yellow is

connected to the RF1 connector marked with yellow (connector on the left). The

OP039 cable marked with blue is connected to the RF2 connector marked with

purple (connector in the middle).

4. Connect the GPS antenna to the connector marked GPS (connector on the right).

5. Windows will have detected the new device and will install the required drivers.

Insert the PCTEL installation CD.

6. Select No, not this time in the Welcome dialog.

Page 26: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 26

7. Select Install from a list of specific location and click Next.

8. Select Include this option in the search and browse to folder

D:\EdgeportUSB\Edgeport Vendor Data\driver vx.x. Click Next to start the

installation.

9. When the installation is finished, click Finish. Windows will automatically install

some additional drivers and report when the device is ready to be used.

Page 27: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 27

Connecting the PCTEL MX GSM/WCDMA Scanner

Installing the SeeGull MX Device Driver

Please follow the following steps to install the device driver.

1. To install the driver the user must have administrative rights to its PC, and the

Take ownership of files or other objects policy has to be enabled for this user

on this PC.

2. Browse to folder seegull mx driver\MX winusb driver. For 32-bit operating system

run DPInst.exe from “install x86” folder and for 64-bit operating system run

DPInst.exe from “install x64” folder.

3. The PCTEL USB Device Installer window will appear. Click Next.

4. If a Windows Security message appears, click Install.

5. Click Finish in the installation completed window.

6. Remove the yellow plastic caps from the antenna, power and GPS connectors in

the front panel.

Page 28: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 28

7. Connect the power cable to the PWR connector in the front panel. Connect the

other end of the cable to a cigarette lighter socket. The Status indicator in the

front panel will light up.

8. Connect the antenna cables. The label on the scanner lists the frequencies of the

radio modules connected to each specific port, labeled RF1 to RF8. The antenna

ports that require antenna connections are identified by their “frequency” on the

label. Since each SeeGull MX is configured to minimize the number of ports

necessary for use, some ports may be inactive for a particular configuration and

are indicated by a blank box.

Page 29: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 29

9. Connect the GPS antenna to the connector marked GPS.

10. Connect the USB data cable to the USB port in the front panel. Connect the other

end of the USB data cable to your PC.

11. Windows Vista and Windows 7 will automatically detect and install the device.

12. With Windows XP a Found new Hardware window will appear. Select No, not

this time in the Welcome window. Select Install the software automatically

(Recommended) and click Next. Finally click Finish.

13. Go to Start | Control Panel | System | Hardware | Device Manager and select

Ports. Memorize the port number for the PCTEL Communications Port item, as

you will need it later on.

Connecting PCTEL PCT Scanners

Installing PL2303 Prolific DriverInstaller Driver

1. Run the PL2303_Prolific_DriverInstaller_vx.x.exe (x refers to the version number)

file on the installation CD.

2. Click Next in the Welcome window that appears.

Page 30: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 30

3. Click Finish to finish the driver installation.

4. Next, remove the yellow plastic caps from the antenna and GPS connectors in the

front panel of the PCTEL PCT scanner.

5. Connect the antenna cable in the RF Input connector.

6. Connect the data cable to the Data connector. Connect the other end of the USB

data cable to your PC.

Page 31: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 31

7. Connect the power cable to the Power connector in the front panel. Connect the

other end of the cable to a cigarette lighter socket.

8. Windows automatically detects the new hardware.

9. Go to Start | Control Panel | System | Hardware | Device Manager and select

Ports. Memorize the port number for the Prolific USB-to-Serial Comm Port

item, as you will need it later on.

Page 32: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 32

Connecting the Rohde & Schwarz TSMQ/TSML Scanner

Note that your PC must have a FireWire (IEEE1394) port in it and a 32-bit PC

FireWire controller card for you to be able to connect a Rohde & Schwarz

TSMQ Scanner

Driver installation:

1. First, install the TSMxDriverInstall.exe file on the installation CD.

2. Click Run to run the installation file.

3. Click Next in the Welcome window that appears.

Page 33: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 33

4. Next, connect the antenna cable to the RF Input connector in the Rohde &

Schwarz scanner.

5. Connect the FireWire cable to one of the IEEE ports and the other end to your PC

or a FireWire adapter in the PC.

Page 34: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 34

6. Next, connect the power cable to the DC IN connector and the other end to a

power source.

7. Windows automatically detects the new hardware. Select No, not this time and

click Next in the Welcome window that appears.

Page 35: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 35

8. Select Install the software automatically (Recommended), and click Next.

9. Click Finish to finish the installation.

10. Go to Device Manager from Start | Control Panel | System | Hardware | Device

Manager. You should see the Rohde & Schwarz TSMx Devices item, and the

applicable Rohde & Schwarz scanner model under it.

Page 36: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 36

Connecting the Rohde & Schwarz TSMW Scanner

1. First, connect antenna cables to the RF1 and RF2 input connectors. See chapter

System Priority Order with R&S TSMW Scanners on page 38 for information on

connecting the antennas to the correct ports.

2. Next, connect the network cable connector to the LAN connector in the scanner.

Note that the network port in the computer to which the cable is connected

should be at least 1 Gbps.

Page 37: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 37

3. Connect the power cable to the DC IN port in the scanner, and the other end of

the cable to a power source.Connect the power cable either to a Mascot power

supply, or with the applicable cigarette lighter adapter, to a cigarette lighter

socket.

4. Next, you need to make some changes to your PC’s network card properties. Go

to Start | Control Panel | Network Connections, and right-click on Local Area

Connection, and select Properties. In the Local Area Connection Properties

dialog, select Internet Protocol (TCP/IP) and click on Properties. Select Use

the following IP address. You need to type in an IP address within the range of

192.168.0.1 - 192.168.0.255. The default IP address for the scanner is

192.168.0.2, so it should be avoided. Next, type 255.255.0.0 in the Subnet mask

field. Click OK and Close to exit the dialogs.

Page 38: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 38

5. In Windows 7, go to Start | Control Panel | Network and Internet | Network and

Sharing Center. Select Local Area Connection in the View your active

networks list. In the Local Area Connection Status dialog, select Properties. In

the Local Area Connection Properties dialog that opens, select the Networking

tab, and Internet Protocol Version 4 (TCP/IPv4) in the This connection uses the

following items view. Click on Properties. Select Use the following IP address.

You need to type in an IP address within the range of 192.168.0.1 -

192.168.0.255. The default IP address for the scanner is 192.168.0.2, so it should

be avoided. Next, type 255.255.0.0 in the Subnet mask field. Click OK and Close

to exit the dialogs.

6. The device is now connected to the computer. See Starting Devices below for

information on how to connect the scanner with Nemo Outdoor.

System Priority Order with R&S TSMW Scanners

Multiple cellular technologies (systems) are measured in a parallel manner. The

different systems are arranged in a priority order as shown in Figure 4. The CDMA

and EVDO systems are counted as one system. Nemo Outdoor handles priority and

allocates the RF ports automatically. In this case priority refers to the order in which

systems are allocated to RF port #1 and RF port #2. The resource slot number

defines in how many processes one RF port is divided.

Both ports, RF #1 and RF #2, have 100% of available resources. When only one

system (except LTE) is measured, for example WCDMA, it is set to be measured via

RF port #1 with 100% of its resources. When two systems are measured

simultaneously, for example GSM and WCDMA, GSM has higher priority over

WCDMA. GSM is set to be measured via RF port #1 with 100% of its resources,

whereas WCDMA system is set to be measured via RF port #2 with 100% of its

resources.

When three systems are measured simultaneously, for example GSM, WCDMA and

CDMA, the systems are again allocated in the priority order for the two RF ports. In

this case RF port #1 is shared by two systems: GSM and CDMA. Each system gets

50% of the RF port #1 resources. 100% of RF port #2 resources are allocated to

WCDMA measurements.

With LTE, individual carriers are allocated to the two RF ports. For example, when

measuring two or more LTE carriers, carriers are arranged in order from lowest

frequency number to the highest. After that, carriers (frequencies) are allocated to

the RF ports so that the first carrier is allocated to RF port #1 and the second carrier

to RF port #2, third carrier is again allocated to RF port #1 and the fourth carrier to

RF port #2, etc.

If the measurement setup includes an odd number of other systems in addition to

LTE, the first LTE carrier is allocated to RF port #2. The second LTE carrier is

allocated to RF port #1, etc. However, if the measurement setup includes only one

other system in addition to LTE, the other system is allocated to RF port #1 and all

LTE carriers are allocated to RF port #2.

Page 39: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 39

Spectrum scanning is counted as one of the systems. Spectrum scanning always

has the highest priority and it is set to be measured via RF port #1. The resource slot

number defines in how many processes one RF port is divided.

Page 40: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 40

STARTING DEVICES

Starting Nemo Outdoor:

1. Start Nemo Outdoor from the Start menu, Nemo Tools submenu.

2. Do not load any previous device configuration if asked.

Starting Nemo FSR1 Scanner

1. From the Measurement menu, select Add New Device.

2. Click on Scanner.

3. From the list select Nemo FSR1 and click Next.

4. In the Scanner Properties dialog, select Nemo Scanner LAN as the Port and

click OK.

Page 41: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 41

5. If the dialog did not close, the start up did not succeed. Check the cable

connections and the settings and try again.

6. If the Device Info window is not visible, open it from the View menu. A green light

should be blinking. This means that the device is working properly and scanning

using the default settings. If the status field displays, Device is not started, check

that you are in online mode (click the Work Offline/Online button ). If the

device is started but not scanning, check that you have selected channels to be

scanned.

Starting Anritsu Scanners

1. From the Measurement menu, select Add New Device.

2. Click on Scanner.

3. From the list select:

For Anritsu ML8720B: Anritsu ML8720B UMTS 2100 and click Next.

For Anritsu ML8720C without the GSM option: Anritsu ML8720C UMTS

2100 and click Next.

For Anritsu ML8720C with the GSM option: Anritsu ML8720C GSM/UMTS

and click Next.

For Anritsu ML8740A and Anritsu ML8740B without the GSM option: Anritsu

ML8740A/ ML8740B UMTS 2100 and click Next.

For Anritsu ML8740A and Anritsu ML8740B with the GSM option: Anritsu

ML8740A/ML8740B GSM/UMTS and click Next.

For Anritsu MS2721B DVB-H Analyzer: Anritsu MS2721B DVB-H, and click

Next.

For Anritsu MS2721B Spectrum Analyzer: Anritsu MS2721B Spectrum

Analyzer, and click Next.

Page 42: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 42

4. In the Scanner Properties dialog, set the COM Port to the port the scanner is

connected to (ML8720B/ML8720C)/select the USB port (e.g., Anritsu USB1)/or

select the Anritsu LAN 1-4 with Anritsu MS2721B DVB-H depending on which IP

address was selected for the scanner.

The next step is not valid for the Anritsu ML8740A, Anritsu ML8740B, Anritsu

MS2721B DVB-H, or Anritsu MS2721B Spectrum Analyzer scanner.

5. Set the baud rate to the one used by the scanner and click OK. Note that the

baud rate must be the same that you chose when you were connecting the

scanner. The dialog will be closed and the scanner should now be connected to

the system.

6. If the dialog did not close, the start up did not succeed. Check the cable

connections and the settings and try again.

7. If the Device Info window is not visible, open it from the View menu. A green light

should be blinking. This means that the device is working properly and scanning

using the default settings. If the status field displays, Device is not started, check

that you are in online mode (click the Work Offline/Online button ).

Page 43: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 43

Starting DRT Scanners

1. From the Measurement menu, select Add New Device.

2. Click on Scanner.

3. From the list select:

DRT WIMAX 2300, if you want to make measurements with the 2300 MHz

(WiMAX) band.

DRT WIMAX 2500, if you want to make measurements with the 2500MHz

(WiMAX) band.

DRT WIMAX 3500, if you want to make measurements with the 3500MHz

(WiMAX) band.

4. In the Scanner Properties dialog, set the COM Port to DRT LAN.

Page 44: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 44

Note that the no changes need to be made to the Baud rate, Antenna gain, and Cable loss

fields. See the next chapter for further instructions on how to make measurements.

Starting PCTEL Scanners

Starting the GPS:

With the PCTEL LX WCDMA scanner you can use either the GSP receiver integrated into the

scanner or an external GPS. See page 47 for instructions on how to enable the integrated GPS

receiver.

Note that you cannot use both the integrated and an external GPS receiver at the same

time.

Note that with the PCTEL LX GSM/WCDMA scanner the Internal GPS receiver should be

activated only in UMTS mode.

To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix

at least 30 seconds before starting the Nemo Outdoor application in online mode. If the

existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the

configuration file in offline mode. If scanner does not send any results after 30 seconds,

it is advised to send a reset command to the scanner via the user interface.

1. From the Measurement menu, select Add New Device.

2. Click on GPS.

3. From the list, select the GPS model that you have connected to the PC and click Next.

4. The GPS Properties dialog is opened. Set the parameters (see the GPS User Manual for

instructions). They should be correct by default. Click OK. The view will return to the Nemo

Outdoor main window.

Page 45: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 45

5. From the View menu activate Device Info. A check mark will appear next to the command

when it is activated.

6. In the Device Info window a green light should be blinking. This means that the GPS is

working properly.

Starting the PCTEL LX/EX/PCT GSM/WCDMA/1xEV-DO/LTE Scanner:

1. From the Measurement menu, select Add New Device.

2. Click on Scanner.

3. From the list select:

For PCTEL LX UMTS 1700/2100 scanner: PCTEL LX UMTS 1700/2100, and click

Next.

For PCTEL LX UMTS 1900 scanner: PCTEL LX UMTS 1900, and click Next.

For PCTEL LX UMTS 2100 scanner: PCTEL LX UMTS 2100, and click Next.

For PCTEL LX UMTS 850/1900 scanner: PCTEL LX UMTS 850/1900, and click Next..

For PCTEL LX UMTS 850 scanner: PCTEL LX UMTS 850, and click Next..

For PCTEL LX CDMA/EV-DO 850 scanner, select PCTEL LX EVDO 800, and click

Next.

For PCTEL EX WCDMA 2100 AWS&GSM 850/ 1900 scanner: PCTEL EX GSM

850/1900 UMTS AWS, and click Next.

For PCTEL LX 1xEV-DO 450 scanner: PCTEL LX EVDO 450, and click Next.

For PCTEL LX 1xEV-DO 850 scanner: PCTEL LX EVDO 800, and click Next.

For PCTEL LX 1xEV-DO 1900: PCTEL LX EDVO 1900, and click Next.

For PCTEL EX CDMA/EV-DO 850/1900 scanner, select CDMA2000 850/1900 EVDO

850/1900, and click Next.

For PCTEL EX GSM 850/1900 & WCDMA 850/1900 scanner: PCTEL EX GSM

850/1900 UMTS 850/1900, and click Next.

For PCTEL EX GSM 900/1800 & WCDMA 900/2100 scanner: PCTEL EX GSM

900/1800 UMTS 900/2100, and click Next.

For PCTEL PCTEL EX GSM 1900 & WCDMA 2100 AWS scanner: PCTEL EX GSM

1900 UMTS AWS, and click Next..

For PCTEL EX WIMAX scanner: PCTEL EX WIMAX, and click Next.

For PCTEL EX 900/1800 WCDMA/TD-SCDMA 2000, select PCTEL EX 900/1800

UMTS TDSCDMA 2000, and click Next.

For PCTEL EX LTE 1800/2600 scanner, select PCTEL EX LTE 1800/2600, and click

Next.

For PCTEL EX LTE 2100 scanner, select PCTEL EX LTE 2100, and click Next.

For PCTEL EX LTE 2100/2600 scanner, select PCTEL EX LTE 2100/2600, and click

Next.

For PCTEL EX LTE 700ABC scanner, select PCTEL EX LTE 700ABC, and click Next.

Page 46: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 46

For PCTEL EX LTE 700C scanner, select PCTEL EX LTE 700C, and click Next.

For PCTEL EX LTE AWS/700BC scanner, select PCTEL EX LTE AWS/700BC, and

click Next.

For PCTEL EX LTE AWS/700C scanner, select PCTEL EX LTE AWS/700C, and click

Next.

PCTEL EX mini series scanners:

o For WCDMA 2100, select PCTEL EX UMTS 2100, and click Next...

o For WCDMA 850/1900, select PCTEL EX UMTS 850/1900, and click Next...

o For WCDMA 900/2100, select PCTEL EX UMTS 900/2100, and click Next...

o For WCDMA AWS, select PCTEL EX UMTS AWS, and click Next...

For PCTEL MX scanners, select PCTEL MX and click Next.

For PCTEL PCT GSM 900/1800 scanner, select PCTEL PCT GSM 900/1800, and click

Next.

For PCTEL PCT UMTS 2100 scanner, select PCTEL PCT UMTS 2100, and click Next.

4. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to.

With MX scanners, select the PCTEL USB item.

5. Set the baud rate to the one used by the scanner and click OK. The dialog will be closed and

the scanner should now be connected to the system.

6. If the dialog did not close, the start-up did not succeed. Check the cable connections and the

settings and try again.

Page 47: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 47

7. From the View menu activate Device Info. A check mark will appear next to the command

when it is activated.

8. A green light on the PCTEL scanner in the Device Info window should be blinking. This

means that the device is working properly and scanning using the default settings. See

chapter Starting Measurement (page 51) for instructions on making your own scanner

configuration.

Enabling integrated GPS receiver for PCTEL LX WCDMA/PCTEL EX WiMAX scanner

1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. In the Measurement Properties dialog click the Advanced button.

3. In the Advanced Properties dialog, select Yes for the Enable Integrated GPS Receiver

check box and click OK.

4. The integrated GPS receiver is now enabled.

Note that you cannot use both the integrated and an external GPS receiver at the same

time.

Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be

activated only with UMTS mode.

To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix

at least 30 seconds before starting the Nemo Outdoor application in online mode. If the

existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the

configuration file in offline mode. If scanner does not send any results after 30 seconds,

it is advised to send a reset command to the scanner via the user interface.

Page 48: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 48

Starting the PCTEL LX GSM/WCDMA dual-mode scanner

1. From the Measurement menu, select Add New Device. Click on Scanner.

2. From the list select PCTEL LX GSM 900/1800 and click Next.

3. In the Scanner Properties dialog, Port field you should see two consecutive COM ports

(e.g., COM 3 and COM 4). Select the COM port with the smaller number and click OK.

4. From the Measurement menu, select Add New Device. Click on Scanner.

5. From the list select PCTEL LX UMTS 2100 and click Next.

6. In the Scanner Properties dialog, Port field you should see two consecutive COM ports

(e.g., COM 3 and COM 4). Select the COM port with the bigger number and click OK.

7. From the View menu activate Device Info. A check mark will appear next to the command

when it is activated.

Page 49: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 49

8. A green light should be blinking in the Device Info for both devices. This means that the

devices are working properly and scanning using the default settings. If the status field

displays, Device is not started, check that you are in online mode (click the Work

Offline/Online button ).

9. The GSM and UMTS scanners will appear as separate devices and must be configured

individually.

Enabling integrated GPS receiver for PCTEL LX GSM/WCDMA dual-mode scanner

Note that with the PCTEL dual-mode scanner the integrated GPS receiver needs to be

enabled only for one scanner.

1. After the PCTEL LX scanners are connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. In the Measurement Properties dialog click the Advanced button.

3. In the Advanced Properties dialog, select Yes in the Enable Integrated GPS Receiver check

box and click OK.

4. The integrated GPS receiver is now enabled.

Note that you cannot use both the integrated and an external GPS receiver at the same

time.

Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be

activated only with UMTS mode.

Page 50: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 50

Starting Rohde & Schwarz Scanners

1. Start Nemo Outdoor. From the Measurement menu, select Add New Device.

2. Click on Scanner.

3. From the list select the applicable R&S scanner, and click Next..

4. In the Scanner Properties dialog, select R&S IEEE1394A in the Port drop-down menu.

Page 51: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 51

STARTING MEASUREMENT

Nemo FSR1 Scanner

GSM+UMTS Scanning

1. Open the Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. In the Measurement Properties dialog you can select the channels to be scanned:

3. On the Frequency scanning, GSM page, click the Select Channels button to select the

GSM channels to be scanned.

Channel style defines the style of the measured channel. For GSM the option is 200 kHz.

Data mode defines the type of measurement data computed from each sample. Note that the

available selection depends on the scanner type.

RX Level Average: the data reported is the average RX level, in dB, of the number of

samples.

Measurement period defines the time in milliseconds for which the scanner measures and then

reports the result.

Sample size defines the number of samples taken from each channel before a measurement

result is written to file.

Page 52: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 52

Selecting the BSIC decoding option displays BSIC value in a measurement window.

Select the BCCH C/I check box to activate C/I measurements for the BCCH channel.

4. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - UMTS

Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The

Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode/Scanning.

To set pilot scanning settings:

1. Open the Measurement Properties dialog box by selecting Measurement | <device> |

General Properties.

2. In the Measurement Properties dialog, go to the Pilot scanning page.

Note that some of the options are enabled/disabled in this dialog according to the

selected scanner model.

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are

below the threshold, the pilots are not reported.

Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow

Band (200kHz) and Wide Band (3.84MHz).

Page 53: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 53

Data processing method defines how the scanned data is processed by the scanner. In

aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is

calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.

Measurement period defines the time in milliseconds for which the scanner measures and then

reports the result.

Pilot measurement mode defines the measurement mode for pilot scanning.

In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,

weak pilots may be undetected.

In High dynamic mode scanning speed is lower but sensitivity is higher.

Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report

results from N best scrambling codes. Number of pilots field defines how many pilots are

reported by scanner in Top-N mode. The maximum number is 32.

Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID

information can be decoded from BCCH messages. Note that this is only enabled in online

mode and if the option has been purchased with the scanner. Cell information decoding is

supported only in WCDMA.

Delay spread defines if the selected scanner will also measure the delay spread value (in

chips) for each scanned scrambling code. Delay spread is determined as the difference

between the last and first component to break the threshold set in PN Threshold.

P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling

code.

S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling

code.

The Top-N Configuration button will open the Select Channels dialog where you can select

channels for pilot scanning.

Page 54: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 54

To select channels:

1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N

Configuration button. The Select Channels dialog is opened.

2. The table displays the channel numbers, not the frequencies. If you know the frequency but

not the channel number, the channel number can be calculated by multiplying the frequency

in MHz by five. The channel spacing is always 200 kHz.

3. You can remove channels from the Selected list by selecting a channel and clicking the

Remove button.

4. You can add channels to the Selected list by selecting a channel from the Available list

and clicking the Add button.

5. Click OK to return to the Measurement Properties dialog.

6. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

7. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

8. Click the Start Recording button to start recording the results in an output file.

Page 55: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 55

Anritsu Scanners

GSM+UMTS Scanning

1. Open the Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. In the Measurement Properties dialog you can select the channels to be scanned:

If the scanner supports only one carrier, you can select either GSM or UMTS channels to

be scanned.

If the scanner supports two carriers, you can select for scanning both GSM and UMTS

channels. If you select GSM channels, you can select a maximum of one UMTS

channel. If you do not select GSM channels, you can select one or two UMTS channels.

3. On the Frequency scanning, GSM page, click the Select Channels button to select the

GSM channels to be scanned.

Note that the scanner reports the 32 strongest channels from the selected GSM channels.

Channel style defines the style of the measured channel. For GSM the options are 200 kHz

and 30 kHz narrow.

Data mode defines the type of measurement data computed from each sample. Note that the

available selection depends on the scanner type.

Page 56: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 56

RX Level Average: the data reported is the average RX level, in dB, of the number of

samples.

RX Level Maximum: the data reported is the maximum RX level, in dB, of the number of

samples.

RX Level Minimum: the data reported is the minimum RX level, in dB, of the number of

samples.

RX Level Standard Deviation: the data reported is the standard of deviation of the

number of samples reported as an integer.

RX Level 10%: the data reported is the 10th percentile RX level, in dB, of the number of

samples.

RX Level 50%: the data reported is the 50th percentile RX level, in dB, of the number of

samples.

RX Level 90%: the data reported is the 90th percentile RX level, in dB, of the Number of

samples.

Measurement period defines the time in milliseconds for which the scanner measures and then

reports the result.

Sample size defines the number of samples taken from each channel before a measurement

result is written to file.

Selecting the BSIC decoding option displays BSIC value in a measurement window.

BSIC Threshold defines the minimum BSIC level that the scanner reports.

BCCH C/I option is available with PCTEL and Rohde&Schwarz GSM scanners only.

4. Click the Start Recording button to start recording the results in an output file.

Page 57: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 57

TOP-N Pilot Scanning - UMTS

Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The

Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode/Scanning.

To set pilot scanning settings:

3. Open the Measurement Properties dialog box by selecting Measurement | <device> |

General Properties.

4. In the Measurement Properties dialog, go to the Pilot scanning page.

Note that some of the options are enabled/disabled in this dialog according to the

selected scanner model.

Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow

Band (200kHz) and Wide Band (3.84MHz). For Anritsu scanners, only Wide Band is available.

Data processing method defines how the scanned data is processed by the scanner. In

aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is

calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.

Measurement period defines the time in milliseconds for which the scanner measures and then

reports the result.

Number of fingers defines the maximum number of fingers used for RAKE in measurement.

Page 58: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 58

Selective level determines a valid path. Set a value (in dB) to decide a valid path from the

noise floor (average value).

Rake threshold determines a valid path (in dB). Subtracting the set value from a path with a

maximum correlation value gives the lower limit of the valid path.

Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report

results from N best scrambling codes. Number of pilots field defines how many pilots are

reported by scanner in Top-N mode.

Delay profile check box enables/disables delay profile scanning. The Channel number field

provides a list of channels that can be selected for scanning.

Finger check box enables and disables Finger measurements for the scanner.

P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling

code.

SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for

each scrambling code.

S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling

code.

The Top-N Configuration button will open the Select Channels dialog where you can select

channels for pilot scanning. If you press the arrow, a drop-down menu will appear from where

you can select Top-N Search Configuration.

Please note that the Top-N Search Configuration dialog is available for Anritsu UMTS

scanners only.

Page 59: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 59

In the Top-N Search Configuration dialog you can limit the search performed by the scanner

and consequently speed up the search.

Group specifies the group number for the primary scrambling code in the range of 0 to 63.

Cell specifies the cell number for the primary scrambling code in the range of 0 to 7.

Secondary code specifies the secondary scrambling code. Limit range should be set from 0 to

0.

Channelization code specifies the channelization code. Limit range should be set from 0 to 0.

Search method defines how the search is performed. P-CPICH (primary common pilot

channel) searches with P-CPICH. SCH performs a three-step search with P-SCH and S-SCH.

To select pilot parameters:

1. Check the TOP-N Mode check box.

2. Set the Number of Scrambling codes value. This defines how many strongest pilots are to

be reported by the scanner. The maximum is 32 pilots.

Page 60: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 60

To select channels:

9. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N

Configuration button. The Select Channels dialog is opened.

10. The table displays the channel numbers, not the frequencies. If you know the frequency but

not the channel number, the channel number can be calculated by multiplying the frequency

in MHz by five. The channel spacing is always 200 kHz.

With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you

are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be

selected.

11. You can remove channels from the Selected list by selecting a channel and clicking the

Remove button.

12. You can add channels to the Selected list by selecting a channel from the Available list

and clicking the Add button.

13. Click OK to return to the Measurement Properties dialog.

To select search parameters:

1. Open the Measurement Properties, Pilot scanning, UMTS page. Press down the Top-N

Configuration button and select Top-N Search Configuration.

Page 61: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 61

2. The Top-N Search Configuration dialog opens.

3. Set the Group search range. The group number is the scrambling code divided by 8. For

example, SC (scrambling code) 12 = group 1, cell 4.

4. Set the Cell search range. The cell number is the division modulus. For example, SC

(scrambling code) 12 = group 1, cell 4.

Page 62: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 62

5. The Secondary Code and the Channelization Code ranges should be set from 0 to 0 for

scanning only the P-CPICH.

6. Select the Search Method. SCH means that the P-CPICH are searched using P-SCH and

S-SCH. P-CPICH means that the P-CPICH are searched without using P-SCH and S-SCH.

Note that the P-CPICH method is much slower than the SCH method.

7. Click OK to accept the settings and to return to the Measurement Properties dialog.

8. Data processing method defines how the scanner will process samples before reporting.

9. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data

processing method is used.

In pilot scanning mode, the RSSI is always measured for each channel.

In pilot scanning mode the P-CPICH Ec/N0 and RSCP are always measured for each

scrambling code.

10. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

11. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

12. Click the Start Recording button to start recording the results in an output file.

Page 63: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 63

Pilot Scrambling Code Scanning - Anritsu Scanners

Pilot Scrambling Code Scanning or Known Scrambling Code Scanning can be used to scan

known pilots. The Known Scrambling Code Scanning will from now on be referred to as Normal

Pilot Mode.

1. Open the Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. Go to the Measurement Properties, Pilot scanning, UMTS page .

3. Deselect the TOP-N mode option and click the Select Channels button. The Select

Scrambling Codes dialog is opened.

4. Select channels in the Selected channel numbers table by clicking the Select button.

With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you

are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be

selected.

5. For each selected channel, select scrambling codes. Select a channel and click the Select

button below the Selected scrambling codes table.

6. Click OK to return to the Measurement Properties dialog.

Page 64: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 64

7. When using an Anritsu scanner in Pilot Scanning mode, you can define the measurement

period. It defines the time period from which results are gathered and processed before

reporting.

8. Data processing method defines how the scanner will process samples before reporting.

In Pilot Scanning Mode the RSSI is always measured for each channel.

In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each

scrambling code.

9. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

10. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

11. Click the Start Recording button to start recording the results in an output file.

Page 65: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 65

DVB-H Scanning

DVB-H scanning can be performed with the Anritsu MS2721B DVB-H Analyzer scanner.

1. Open the Measurement Properties dialog box by selecting Measurement | <device> |

General Properties.

2. In the Measurement Properties, Pilot scanning, DVB-H page, select a frequency to be

measured. Anritsu MS2721B DVB-H Analyzer scans frequencies between (DVB-H) 474 -

850 MHz.

3. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

4. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

5. Click the Start Recording button to start recording the results in an output file.

Page 66: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 66

Spectrum Analyzer Measurements

DVB-H scanning can be performed with the Anritsu MS2721B Spectrum Analyzer scanner.

1. Open the Measurement Properties dialog box by selecting Measurement | <device> |

General Properties.

2. In the Measurement Properties dialog, go to the Spectrum scanning page.

Page 67: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 67

3. Select the Enable spectrum scanning option and click on Add.

4. Define the start and stop frequencies within which the measurement will be performed. If

you manually define the start and stop frequencies, you can either select to add the

frequencies to the scanning list or save them as a predefined set. Select your option in the

Add to scanning list menu.

5. Select Set center frequency and bandwidth to define the center frequency and the

bandwidth to be measured. If you manually define the center frequency and bandwidth, you

can either select to add them to the scanning list, or save them as a predefined set. Select

your option in the Add to scanning list menu.

With Anritsu MS2721B spectrum analyzer the supported frequency range is from 9 kHz to

7.1GHz. The sample count is fixed to 551, and RBW is adjusted automatically. RBW is

between 1 Hz - 3 MHz. It is automatically adjusted to the closest value of 1 Hz, 3 Hz, 10 Hz,

30Hz, 100 Hz ... 300 kHz, 1 MHz, 3 MHz.

6. When signal volume is lower than -50dBm, selecting the Use preamplifier functionality in

the Measurement Properties dialog can increase the scanner’s measuring sensitivity,

hence slightly decreasing background noise. However, it is recommended that it is not

selected when signal volume is higher than -50dBm.

7. You can add scanning sets in the Predefined scanning sets field through the Add to

Scanning List button. Click the arrow in the button and select Save as Predefined Set.

Define a name in the Enter Frequency Set Name field and click OK.

Page 68: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 68

8. The name appears in the Predefined scanning sets field along with the chosen frequency

and/or bandwidth information selected in the Reporting field.

9. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

10. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

11. Click the Start Recording button to start recording the results in an output file.

Page 69: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 69

PCTEL Scanners

Frequency Scanning – PCTEL GSM/UMTS Scanners

Frequency scanning can be used to scan band power. It is also useful for checking that the

band is clear and for finding out the center frequency.

1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement

Properties dialog by selecting Measurement | <device> | General Properties.

2. In the Measurement Properties dialog, go to the Frequency scanning, UMTS page.

3. In the Channel style field, select the channel width. The options are narrow band (200 kHz)

and wide band (3.84 MHz).

To find out the center frequency used, set the Channel Style to 200 kHz and select all the

channels in the frequency region where the carrier should exist; for example, all channels

allocated to an operator. The center frequency will stand out in Frequency Scanning

mode. The received signal should be above the noise level in order to find out the center

frequency.

Page 70: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 70

4. Click the Select Channels button to open the Select Channels dialog.

5. The table displays the channel numbers, not the frequencies. If you know the frequency but

not the channel number, the channel number can be calculated by multiplying the frequency

in MHz by five. The channel spacing is always 200 kHz.

6. Remove channels from the Selected list by selecting a channel and clicking the Remove

button.

7. Add channels to the Selected list by selecting a channel from the Available list and clicking

the Add button.

8. Click OK to return to the Measurement Properties dialog.

9. Click OK and OK to close the Measurement Properties dialog and to re-start the scanner

with the new settings.

10. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

11. Click the Start Recording button to start recording the results in an output file.

Page 71: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 71

Frequency Scanning – PCTEL EX LTE Scanner

1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement

Properties dialog by selecting Measurement | <device> | General Properties. By clicking

the Advanced button on the General page, you will access the Advanced Properties

dialog. Here you can enable and disable the integrated GPS receiver. This means you will

not need an external GPS receiver in order to collect position data.

2. On the Frequency scanning page, define the Channel style.

Page 72: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 72

3. By clicking the Select Channels button, you can access the Select Channels dialog.

4. Select one band from the list or all of them. You can also select one band at a time and add

the bands you want to scan. If all bands are selected, you have the possibility to select

Remove All | ... items from every band. Alternatively, if only one band is selected you can

remove only items from the current band through Remove All | ...items from current band.

The Available view provides a list of channels that are available for scanning. To add

channels to the Selected list, click on a number in the Available list and then click the Add

button or simply double-click a channel to add it to the Selected list. To select all available

channels for scanning, click the Add All button. An alternative method to select channels is

to type the channel numbers in the field at the bottom of the dialog and to click Add.

To remove channels from the Selected list, click on the channel you want to remove and

then click the Remove button or double-click the channel. To remove all channels, click the

Remove All button. You can select several channels simultaneously by holding down the

SHIFT key and clicking on the channels you want to add or remove.

5. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

6. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

7. Click the Start Recording button to start recording the results in an output file.

Page 73: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 73

Frequency Scanning – PCT GSM Scanner

1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement

Properties dialog by selecting Measurement | <device> | General Properties.

2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here

you can enable and disable the integrated GPS receiver. This means you will not need an

external GPS receiver in order to collect position data.

3. Go to the Frequency scanning page.

Channel style refers to the style of the channel.

Selecting the BSIC decoding option displays BSIC value in a measurement window.

BSIC threshold defines the minimum BSIC level that the scanner reports.

Select the BCCH C/I check box to activate C/I measurements for the BCCH channel. This

option is available with PCTEL GSM scanners only.

Page 74: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 74

4. By clicking the Select Channels button, you can access the Select Channels dialog.

5. Select one band from the list or all of them. You can also select one band at a time and add

the bands you want to scan. If all bands are selected, you have the possibility to select

Remove All | ... items from every band. Alternatively, if only one band is selected you can

remove only items from the current band through Remove All | ...items from current band.

The Available view provides a list of channels that are available for scanning. To add

channels to the Selected list, click on a number in the Available list and then click the Add

button or simply double-click a channel to add it to the Selected list. To select all available

channels for scanning, click the Add All button. An alternative method to select channels is

to type the channel numbers in the field at the bottom of the dialog and to click Add.

To remove channels from the Selected list, click on the channel you want to remove and

then click the Remove button or double-click the channel. To remove all channels, click the

Remove All button. You can select several channels simultaneously by holding down the

SHIFT key and clicking on the channels you want to add or remove.

Note that Sample size and Data mode are not enabled with PCT GSM frequency scanning

Page 75: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 75

6. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

7. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

8. Click the Start Recording button to start recording the results in an output file.

Frequency Scanning – PCTEL EVDO Scanners

1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement

Properties dialog by selecting Measurement | <device> | General Properties.

2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here

you can enable and disable the integrated GPS receiver. This means you will not need an

external GPS receiver in order to collect position data.

3. Go to the Frequency scanning page.

Channel style refers to the style of the channel. For EV-DO scanners, the options are 1250

kHz Normal and 30 kHz Normal.

Sample size defines the number of samples taken from each channel before a measurement

result is written to file.

Page 76: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 76

4. By clicking the Select Channels button, you can access the Select Channels dialog.

5. Select one band from the list or all of them. You can also select one band at a time and add

the bands you want to scan. If all bands are selected, you have the possibility to select

Remove All | ... items from every band. Alternatively, if only one band is selected you can

remove only items from the current band through Remove All | ...items from current band.

The Available view provides a list of channels that are available for scanning. To add

channels to the Selected list, click on a number in the Available list and then click the Add

button or simply double-click a channel to add it to the Selected list. To select all available

channels for scanning, click the Add All button. An alternative method to select channels is

to type the channel numbers in the field at the bottom of the dialog and to click Add.

To remove channels from the Selected list, click on the channel you want to remove and

then click the Remove button or double-click the channel. To remove all channels, click the

Remove All button. You can select several channels simultaneously by holding down the

SHIFT key and clicking on the channels you want to add or remove.

6. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

7. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

8. Click the Start Recording button to start recording the results in an output file.

Page 77: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 77

TOP-N Pilot Scanning PCTEL - UMTS

Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The

Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode.

1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement

Properties dialog by selecting Measurement | <device> | General Properties.

2. Go to the Pilot scanning page.

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are

below the threshold, the pilots are not reported.

Channel style refers to the style of the channel.

Data processing method defines how the scanned data is processed by the scanner. In

aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is

calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.

Pilot measurement mode defines the measurement mode for pilot scanning.

In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,

weak pilots may be undetected.

In High dynamic mode scanning speed is lower but sensitivity is higher.

Page 78: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 78

Top-N check box enables/disables Top-N scrambling code scanning. If enabled, scanner will

report results from N best scrambling codes. Number of pilots field defines how many pilots

are reported by scanner in Top-N mode.

Time of arrival defines if the selected scanner will measure the time of arrival for each

scrambling code. The time of arrival value is relative to GPS time and is measured in chips.

Delay spread defines if the selected scanner will also measure the delay spread value (in

chips) for each scanned scrambling code. Delay spread is determined as the difference

between the last and first component to break the threshold set in PN Threshold.

P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling

code.

SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for

each scrambling code.

S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling

code.

To select channels:

1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N

Configuration button. The Select Channels dialog is opened.

The table displays the channel numbers, not the frequencies. If you know the frequency

but not the channel number, the channel number can be calculated by multiplying the

frequency in MHz by five. The channel spacing is always 200 kHz.

2. Remove channels from the Selected list by selecting a channel and clicking the Remove

button.

3. Add channels to the Selected list by selecting a channel from the Available list and clicking

the Add button.

With a PCTEL LX scanner a maximum of 8 channels can be selected in the pilot mode.

With a PCTEL EX scanner a maximum of 15 channels can be selected in the pilot mode.

With a PCTEL MX scanner 1 channel can be selected in the pilot mode.

With a PCTEL LTE EX scanner a maximum of 15 channels can be selected in the pilot

mode.

With a PCTEL PCT scanner a maximum of 4 channels can be selected in the pilot mode.

4. Click OK to return to the Measurement Properties dialog.

To select pilot parameters:

1. Check the TOP-N Mode check box.

2. Set the Number of scrambling codes value. This defines how many strongest pilots are to

be reported by the scanner. The maximum is 32 pilots.

Note that with the PCTEL PCT Scanner the maximum number of pilots to be selected for

scanning is 8.

Page 79: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 79

Note that the PCTEL EX WCDMA scanner only supports the TOP-N mode. You can select

up to 32 pilots for scanning.

3. To improve on the accuracy of radio propagation models, High speed mode makes it

possible to acquire more samples (max 32 pilots per channel), while High dynamic mode

offers fewer samples (max 16 pilots per channel) with a larger dynamic range.

To set general parameters:

1. Data processing method defines how the scanner will process samples before reporting.

2. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data

processing method is used.

To select measured values:

In Pilot Scanning Mode the RSSI is always measured for each channel.

In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each

scrambling code.

1. In the Measurement Properties, Pilot scanning page:

Select the P-SCH option to enable P-SCH Ec/N0 and RSCP measurement.

Select the S-SCH option to enable S-SCH Ec/N0 and RSCP measurement.

Select the Time of arrival option to enable time of arrival measurement.

Select the Delay spread option to enable P-CPICH delay spread measurement.

Select the SIR option to enable P-CPICH SIR measurement.

Select the Delay profile option to enable P-CPICH Delay Profile measurement. In TOP-

N pilot scanning mode the scrambling code for delay profile measurement cannot be

selected.

2. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

3. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

4. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - PCTEL EX/LX, EVDO

Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The

Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode.

1. After the PCTEL LX/EX scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here

you can enable and disable the integrated GPS receiver. This means you will not need an

external GPS receiver in order to collect position data.

Page 80: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 80

3. In the Measurement Properties dialog, go to Pilot scanning page.

Channel style refers to the style of the channel.

Data processing method defines how the scanned data is processed by the scanner. In

aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is

calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.

Pilot window mode defines the position of the chips that are searched for pilot across in regard

to the ideal pilot position (0 chip delay for a given pilot).

Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1,

1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every

second sample is logged, with ratio 1:4 every 4th sample is logged, and with ratio 1:8 every 8th

sample is logged. By decreasing the sampling ratio you can decrease the output file size, but

the scanning accuracy will be diminished.

Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the

threshold, the pilots are not scanned.

Top-N check box enables/disables Top-N scrambling code scanning. If enabled, scanner will

report results from N best scrambling codes. Number of pilots field defines how many pilots

are reported by scanner in Top-N mode.

Page 81: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 81

Delay check box enables/disables delay profile scanning. Delay is defined as the measured

difference between the expected arrival time (GPS time) and the actual arrival time of the

maximum peak above the PN threshold. It is reported in chips.

4. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

5. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

6. Click the Start Recording button to start recording the results in an output file.

Spectrum Scanning - PCTEL EX

Spectrum scanning is enabled on PCTEL EX scanners only in online mode. Hence, the device

needs to be added to Nemo Outdoor in online mode to activate the Spectrum scanning

functionality

1. After the PCTEL EX scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. In the Measurement Properties dialog, go to the Spectrum scanning page.

Page 82: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 82

3. Select the Enable spectrum scanning option, and click Add.

4. To create new scanning sets, define the scanning frequencies in the Reporting view.

Set start and stop frequencies defines the frequency range that will be scanned.

Set center frequency and bandwidth defines the frequency range that will be scanned.

The Sample count field determines the sample count measured for the given frequency range.

5. The Add to Scanning List menu enables you to decide whether the new scanning set is

added to the scanning list, or saved as a predefined set also for later use.

6. The Predefined scanning sets can be used to quickly select the frequency range to be

scanned. Select a set from the list, and click on Add to Scanning List.

With PCTEL EX scanning receivers, the internal frequency range is defined with start

frequency, resolution bandwidth (RBW) and number of points. Stop frequency = start frequency

+ (frequency spacing) * (number of points – 1). All the points need to be within the frequency

range of the requested RF Band. Frequency spacing is between the center frequencies and

spacing between points is half of the resolution bandwidth. The maximum number of samples

(points) is 2560. As seen in the formula above, stop frequency is calculated based on start

frequency and number of points. Stop frequency set by the user is only requested value but it is

not necessarily used during the measurement.

Page 83: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 83

If the requested frequency range is not supported by the device, Nemo Outdoor automatically

adjusts the frequency range for the device, and only frequency ranges supported by the

scanning receiver are used to make spectrum analyzer measurements. The number of samples

is used only for the frequency range supported by the scanning receiver. Nemo Outdoor does

not read the supported frequency range from the scanning receiver. For example, in the picture

below the user has set start and stop frequencies as seen within the red area. However, the

scanning receiver supports only frequency ranges shown by the green areas. The number of

samples is used only for green areas and the correct RBW is selected accordingly.

7. Click OK to return to the Spectrum scanning page.

Page 84: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 84

8. The added frequency ranges will be added to the Scanning list.

9. To remove items from the scanning list, select one or more, and select Remove All |

Remove Selected Items. Alternatively, click on Remove All to remove every item from the

list.

10. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

11. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

12. Click the Start Recording button to start recording the results in an output file.

Page 85: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 85

LTE OFDM Scanning – PCTEL EX LTE

OFDM scanning can be used for scanning Reference signal / Sync signals with a PCTEL LTE

scanner and Nemo Outdoor.

1. After the PCTEL LTE scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here

you can enable and disable the integrated GPS receiver. This means you will not need an

external GPS receiver in order to collect position data.

3. In the Measurement Properties dialog, go to the Pilot scanning page.

Channel style refers to the style of the channel.

Cyclic prefix defines the type of signal the scanner is set to measure. With Autodetect

selected, the scanner will automatically detect the appropriate signal type.

Data processing method defines how the scanned data is processed by the scanner. In

aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is

calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.

Page 86: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 86

Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1,

1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every

second sample is logged, with ratio 1:4 every 4th sample is logged, and with ratio 1:8 every 8th

sample is logged. By decreasing the sampling ratio you can decrease the output file size, but

the scanning accuracy will be diminished.

RSSI threshold determines a valid path (in dB). Subtracting the set value from a path with a

maximum correlation value gives the lower limit of the valid path.

Top-N check box enables/disables Top-N scrambling code scanning. If enabled, scanner will

report results from N best cells. Number of cells field indicates the number of best cells you

want the scanning to notify you of. Up to 16 sectors are reported with specific cell ID.

CINR check box activates/deactivates Carrier to Interference and Noise Ratio measuring.

Carrier refers to either reference signal power or sync signal power depending on the selected

signal type.

Time offset refers to the number of samples between P-SCH Primary Synchronization Signal

arrival time with respect to receiver frequency reference that is derived from GPS reference

time.

Sync signal refers to the ratio between the synchronization channel, i.e., primary and

secondary signal received power and the interference and noise from the same synchronization

signal set.

Reference signal refers to the ratio between the reference signal received power (RSRP) and

the interference and noise from the same reference signal set.

The Top-N Configuration button will open the Select Channels where you can select

channels for pilot scanning. The maximum number of channels that can be selected is device

specific.

Page 87: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 87

4. When you select LTE channels, you can also define some channel-specific settings. In the

LTE Channel Specific Settings dialog, select the channel from the Selected channels list

and define the settings.

Note that the available options are device specific.

Uplink-downlink configuration refers to LTE TDD frame structure.

Frame structure type 2 is applicable to TDD. Each radio frame of length ms 10307200 sf TT

consists of two half-frames of length ms 5153600 s T each. Each half-frame consists of five

subframes of length ms 107203 s T . The supported uplink-downlink configurations are listed in

the table below where, for each subframe in a radio frame, “D” denotes the subframe is

reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink

transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS.

One s lot, Tslo t=15360 Ts

GPUpPTS

Dw PTS

One radio frame , T f = 307200 Ts = 10 ms

One half-frame, 153600Ts = 5 ms

30720 Ts

One subframe , 30720 Ts

GPU pPTS

DwPTS

Subframe #2 Subframe #3 Subframe #4Subframe #0 Subframe #5 Subframe #7 Subframe #8 Subframe #9

Frame structure type 2 (for 5 ms switch-point periodicity):

Uplink-downlink configuration

Downlink-to-Uplink Switch-point periodicity

Subframe number 0 1 2 3 4 5 6 7 8 9

Page 88: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 88

0 5 ms D S U U U D S U U U 1 5 ms D S U U D D S U U D 2 5 ms D S U D D D S U D D 3 10 ms D S U U U D D D D D 4 10 ms D S U U D D D D D D 5 10 ms D S U D D D D D D D 6 5 ms D S U U U D S U U D

5. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

6. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings.

7. Click the Start Recording button to start recording the results in an output file.

Pilot Scrambling Code Scanning - PCTEL LX

Known Scrambling Code Scanning can be used to scan known pilots. The Known Scrambling

Code Scanning will from now on be referred to as Normal Pilot Mode.

1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. In the Measurement Properties dialog, go to the Pilot scanning page.

Page 89: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 89

3. Deselect the TOP-N mode option and click the Select Channels button. The Select

Scrambling Codes dialog is opened.

4. Select channels in the Selected channel numbers table by clicking the Select button.

With a PCTEL scanner a maximum of 8 channels can be selected in the pilot mode.

5. For each selected channel, select scrambling codes. Select a channel and click the Select

button below the Selected scrambling codes table.

6. Click OK to return to the Measurement Properties dialog.

7. Data processing method defines how the scanner will process samples before reporting.

8. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data

processing method is used.

In Pilot Scanning Mode the RSSI is always measured for each channel.

In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each

scrambling code.

9. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

10. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

11. Click the Start Recording button to start recording the results in an output file.

Page 90: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 90

DRT Scanners

Frequency Scanning

Frequency scanning can be used to scan band power. It is also useful for checking that the

band is clear and for finding out the center frequency.

1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. You can enable or disable the integrated GPS receiver through the Advanced button. It is

also possible to use an external GPS device with the scanner.

3. In the Measurement Properties dialog, go to the Frequency scanning page.

4. In the Channel Style list box, select the channel width. The options are Wide Band (5000

kHz) and Wide Band 2 (10000 kHz).

Page 91: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 91

5. Click the Select Frequencies button to open the Select Frequencies dialog.

6. The table displays the available frequencies. Select and add them in the Selected view by

clicking on Add>>.

7. Remove frequencies from the Selected list by selecting a frequency and clicking the

Remove button.

8. Add frequencies in the Selected list by selecting a frequency from the Available list and

clicking the Add button.

9. Click OK to return to the Measurement Properties dialog.

10. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

11. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

12. Click the Start Recording button to start recording the results in an output file.

Page 92: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 92

Pilot Scanning

1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. In the Measurement Properties dialog, go to the Pilot scanning page.

Channel style refers to the style of the channel.

Data processing method defines how the scanned data is processed by the scanner. In

aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated.

Top-N check box enables/disables TOP-N scrambling code scanning. If enabled, scanner will

report results from N best preambles. Number of preambles field defines how many preambles

are reported by the scanner in TOP-N mode.

CINR refers to the Carrier to Interference and Noise ratio value, in dB *100 (e.g., -16.34). It is

based on the requested reuse factor.

Preamble delay refers to the number of samples between expected arrival time and actual

arrival time of preamble with respect to GPS time reference. The values range from 0 to

1023+32. Each sample corresponds to 89.285 nanoseconds.

Page 93: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 93

Reuse factor refers to a system design parameter that can be manipulated to achieve the

desired balance between the interference and the network coverage. The WiMAX air interface

modulating waveform has been divided into three segments (Segment 0, 1 and 2). The

allocation of frequency sub-carrier into these three segments is done in such a way that e.g. a

downlink signal on segment 0 will not interfere with the downlink signal on segment 1. In a

Reuse Factor 1 measurement, contributions from all the three segments are considered in the

measured parameters, so that the CINRs are calculated from all the three segments. When

Reuse Factor 3 is selected, only the contribution of the desired segment is considered, and the

CINRs are calculated only from the same segment. As a broad guideline, measurements

performed with Reuse Factor 1 will provide the signal quality of the all the detected preambles

relative to each other, whereas the Reuse Factor 3 category of measurements will provide the

signal quality of preambles within the same segment.

Delay spread defines if the selected scanner will also measure the delay spread value (in

chips) for each scanned scrambling code. Delay spread is determined as the difference

between the last and first component to break the threshold set in PN Threshold.

3. The Top-N Configuration button will open the Select Frequencies dialog where you can

select frequencies for scanning. The maximum number of frequencies that can be selected

is device specific.

Page 94: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 94

4. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

5. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

6. Click the Start Recording button to start recording the results in an output file.

Rohde & Schwarz TSMQ/TSML/TSMW Scanner

With Rohde & Schwarz TSMQ, TSML and TSMW scanners you can perform GSM frequency

scanning, GSM/UMTS scanning, CDMA TOP-N Pilot scanning, EVDO TOP-N Pilot scanning,

UMTS TOP-N Pilot scanning, and Spectrum scanning. In addition, it is possible to perform CW

scanning measurements with the TSMQ and TSML scanners and LTE measurements with the

TSMW scanner. It is possible to perform any of the measurements introduced below separately,

any combination of the measurements or all of them simultaneously.

Frequency Scanning - Rohde & Schwarz Scanner, GSM

1. After the Rohde & Schwarz TSMQ/TSML scanner is connected and activated in Nemo

Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> |

General Properties.

Page 95: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 95

Selecting the BSIC decoding check box displays BSIC value in a measurement window.

BSIC threshold defines the minimum BSIC level that the scanner reports.

Select the BCCH C/I check box to activate C/I measurements for the BCCH channel. This

option is available with the PCTEL GSM scanner only.

Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID

information can be decoded from BCCH messages. Note that this is only enabled in online

mode and if the option has been purchased with the scanner.

When the System information decoding option is selected, L3 messages are written in the log

file.

2. Click the Select Channels button to open the Select Channels dialog.

3. The table displays the channel numbers, not the frequencies. If you know the frequency but

not the channel number, the channel number can be calculated by multiplying the frequency

in MHz by five. The channel spacing is always 200 kHz.

4. Select one band from the Band list or all of them. You can also select one band at a time

and add the bands you want to scan. If all bands are selected, you have the possibility to

select Remove All | ... items from every band. Alternatively, if only one band is selected

you can remove only items from the current band through Remove All |...items from

current band.

Page 96: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 96

5. Remove channels from the Selected list by selecting a channel and clicking the Remove

button.

6. Add channels to the Selected list by selecting a channel from the Available list and clicking

the Add button.

7. Click OK to return to the Measurement Properties dialog.

8. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

9. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

10. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - Rohde & Schwarz Scanners, UMTS

1. Open the Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. Go to the Pilot scanning, UMTS page to define UMTS-specific Pilot scanning settings.

Page 97: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 97

CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are

below the threshold, the pilots are not reported.

Channel style refers to the style of the channel.

Data processing method defines how the scanned data is processed by the scanner. In

aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is

calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.

Pilot measurement mode defines the measurement mode for pilot scanning.

In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,

weak pilots may be undetected.

In High dynamic mode scanning speed is lower but sensitivity is higher.

Top-N check box enables/disables Top-N scrambling code scanning. If enabled, scanner will

report results from N best scrambling codes. Number of pilots field defines how many pilots

are reported by scanner in Top-N mode.

Note that the Rohde & Schwarz TSMQ, TSML-W, TSML-GW and TSMW scanners support

only TOP-N mode and High speed and High dynamic pilot measurement modes. In

addition, Data processing method and CPICH Ec/N0 threshold are supported general

settings, and P-SCH, S-SCH, Time of arrival, Delay spread and SIR are supported of the

scanning options.

Time of arrival defines if the selected scanner will measure the time of arrival for each

scrambling code. The time of arrival value is relative to GPS time and is measured in chips.

Delay spread defines if the selected scanner will also measure the delay spread value (in

chips) for each scanned scrambling code. Delay spread is determined as the difference

between the last and first component to break the threshold set in PN Threshold.

When the Missing neighbor detection option is selected, the missing neighbor information

event (NMISS) is written in the log file. You can view the missing neighbor information, for

example, in a grid view.

When the Neighbor list decoding option is selected, the NLIST (neighbor list) event is written

in the log file for both GSM and WCDMA.

Delay profile check box enables/disables delay profile scanning. The Channel number field

provides a list of channels that can be selected for scanning.

P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling

code.

SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for

each scrambling code.

S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling

code.

When the System information decoding option is selected, L3 messages are written in the log

file.

Page 98: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 98

The Top-N Configuration button will open the Select Channels dialog (p.95) where you can

select channels for pilot scanning.

Note that with UMTS the maximum number of channels that can be scanned is 32

channels, and the maximum number of pilots per each channel is 32.

3. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

4. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

5. Click the Start Recording button to start recording the results in an output file.

TOP-N Pilot Scanning - Rohde & Schwarz Scanner, CDMA/EVDO

Note that the EVDO measurements can only be performed in a proper way when a CDMA

2000 channel is measured as well. In this way, the time relationship between the different

PN offsets is resolved.

1. After the Rohde & Schwarz TSMQ scanner is connected and activated in Nemo Outdoor,

open the Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

Page 99: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 99

2. In the Measurement Properties dialog, go to the Pilot Scanning, CDMA page.

Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the

threshold, the pilots are not scanned.

TOP-N mode check box enables/disables TOP-N scrambling code scanning. Number of pilots

field defines how many pilots are reported by the scanner in TOP-N mode.

Overhead message decoding, when selected, enables the scanner to decode PCH

messages.

The Top-N Configuration button will open the Select Channels dialog (p.95) where you can

select channels for pilot scanning.

Note that the Rohde & Schwarz TSMQ scanner supports max 32 channels.

3. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

4. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

5. Click the Start Recording button to start recording the results in an output file.

Page 100: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 100

TOP-N Pilot Scanning - Rohde & Schwarz TSMW, LTE

1. Open the Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

2. Go to the Pilot scanning, LTE page to define LTE-specific pilot scanning settings.

CINR check box activates/deactivates Carrier to Interference and Noise Ratio measuring.

Carrier refers to either reference signal power or sync signal power depending on the selected

signal type.

Sync signal refers to the ratio between the synchronization channel, i.e., primary and

secondary signal received power and the interference and noise from the same synchronization

signal set.

Reference signal refers to the ratio between the reference signal received power (RSRP) and

the interference and noise from the same reference signal set.

Page 101: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 101

The Top-N Configuration button will open the Select Channels dialog (p.95) where you can

select channels for pilot scanning.

When you select LTE channels, you can also define some channel-specific settings. In the LTE

Channel Specific Settings dialog, select the channel from the Selected channels list and

define the settings.

Note that the available options are device specific.

Uplink-downlink configuration refers to LTE TDD frame structure.

Frame structure type 2 is applicable to TDD. Each radio frame of length ms 10307200 sf TT

consists of two half-frames of length ms 5153600 s T each. Each half-frame consists of five

subframes of length ms 107203 s T . The supported uplink-downlink configurations are listed in

the table below where, for each subframe in a radio frame, “D” denotes the subframe is

reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink

transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS.

One slot, Tslot=15360 Ts

GPUpPTS

DwPTS

One radio frame , Tf = 307200Ts = 10 ms

One half -frame, 153600 Ts = 5 ms

30720Ts

One subframe , 30720 Ts

GP UpPTS

DwPTS

Subframe #2 Subframe #3 Subframe #4Subframe #0 Subframe #5 Subframe #7 Subframe #8 Subframe #9

Page 102: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 102

Frame structure type 2 (for 5 ms switch-point periodicity):

Uplink-downlink configuration

Downlink-to-Uplink Switch-point periodicity

Subframe number 0 1 2 3 4 5 6 7 8 9

0 5 ms D S U U U D S U U U 1 5 ms D S U U D D S U U D 2 5 ms D S U D D D S U D D 3 10 ms D S U U U D D D D D 4 10 ms D S U U D D D D D D 5 10 ms D S U D D D D D D D 6 5 ms D S U U U D S U U D

3. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

4. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

5. Click the Start Recording button to start recording the results in an output file.

Spectrum Scanning - Rohde & Schwarz Scanners

1. After the Rohde & Schwarz scanner is connected and activated in Nemo Outdoor, open the

Measurement Properties dialog by selecting Measurement | <device> | General

Properties.

Page 103: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 103

2. In the Measurement Properties dialog, go to the Spectrum scanning page.

Page 104: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 104

3. In the Measurement Properties dialog, select the Enable spectrum scanning option.

Click Add.

4. To create new scanning sets, define the scanning frequencies in the Reporting view.

Set start and stop frequencies defines the frequency range that will be scanned.

Set center frequency and bandwidth defines the frequency range that will be scanned.

The Sample count field determines the sample count measured for the given frequency range.

With Rohde & Schwarz scanner receivers, the user can set the start and stop frequency

between 80MHz and 3000MHz. Sample counts are divided to the frequency range defined by

the user. The TSMx device has a native frequency resolution of 12.8 KHz. It should be noted

that the frequency shift cannot be lower than 12.8kHz, which sets the number of sample count

max. limit to 5000 samples. In case the selected frequency range and sample count require a

frequency shift lower than 12.8kHz, the sample count is automatically decreased. The sweep

speed, resolution bandwidth and sampling rate are fixed. The sweep speed is 1 GHz / 0.1 sec,

the resolution bandwidth is fixed at 30 kHz.

Page 105: 58277508 Nemo Outdoor Scanner Guide

SCANNER GUIDE 105

For example, if the start frequency is 80 MHz, and the stop frequency is 100 MHz, the total

measured bandwidth is 20 MHz. If the sample count is set to 20, power (RMS) is measured

from a 1 MHz bandwidth. With the frequency shift of 12.8 KHz ~ 78 samples are taken from

each 1 MHz bandwidth.

The Add to scanning list menu enables you to decide whether the newly created scanning set

is added to the scanning list, or saved as a predefined set also for later use.

The Predefined scanning sets can be used to quickly select the frequency range to be

scanned. Select a set from the list, and click on Add to scanning list.

5. Click OK to access the Scanning list view.

6. The added frequency ranges will be added to the Scanning list.

7. To remove items from the scanning list, select one or more, and select Remove all |

Remove selected items. Alternatively, click on Remove all to remove every item from the

list.

8. After making the appropriate settings, click OK and OK again and go to online mode to start

the scanning.

9. A green light on the scanner Device Info window should start blinking. This means that the

device is working properly and scanning using the default settings. In TOP-N Mode this may

take a few seconds.

10. Click the Start Recording button to start recording the results in an output file.

TROUBLESHOOTING

If a Scanner synchronization failed error message appears in the Output window, the scanner

is working properly, but the scanner did not find strong enough a CPICH in a short time period.

Nevertheless, the measurement will go on normally.

If a Scanner GPS locking failed error message appears in the Output window, the scanner is

working properly, but the scanner GPS has no fix or is not connected. The measurement will go

on normally, but the scanner accuracy is not as good as it is when the scanner GPS has a fix.