561-MB256 plusbells-security.com/new/pdf/mb256_plus_e.pdf · 057640 Motherboard DS 7500...

2
561-MB256 plus Intrusion detection central control unit Performance features The intrusion detection control unit 561-MB256 is designed for use in private and commercial zones and is highly suitable for setting up medium to large-sized hazard detection systems. It complies with the latest guidelines of the VdS Security Class C as well as the German Electrical Standards 0833, Part 1 and Part 3 of Class 1, Version B. The standard version of the 561-MB256 has the following performance features: 4 conventional detector group inputs 63 BUS-1 users - connectable 64 BUS-2 users - connectable 8 freely programmable semi-conductor outputs as well as 4 freely programmable relays Integrated, monitored alarm signalling device connections Serial and parallel printer interface With the corresponding extension modules as well as BUS-1 and BUS-2 users, a total of 2048 detector groups can be realized. When fully equipped with 32 I/O modules, 1028 conventional inputs (terminating value 12.1 kOhm) are available that can be used as inputs for detectors and switching devices. plus plus Up to 2048 detector groups can be defined, of which 1028 are conventional detector groups Up to 250 main zones can be defined Up to 2583 BUS-1 users can be connected Up to 704 BUS-2 users can be connected, of which max. 50 are operating units Suitable for police emergency call 19" version and add-on operating unit Available with LCD operating unit and printer depending on version Programming via USB in conjunction with PCB/laptop and software package WINFEM Advanced Simple firmware update with Flash-EPROM Operator guidance with plain text display Modular extensible up to max. 32 modules Automatic maintenance interval indication IGIS-LOOP and transmission devices can be integrated (also multiple) Event memory for 4000 events Alarm memory - 20 events per main zone 1000 IDENT-KEY data carrier codes can be managed; up to 250 macros can be defined Access with or without code; up to 750 operating codes; every operating function can be enabled/disabled individually. Technical and fire alarm memory With maximum upgrading with BUS-1 and BUS-2 modules, up to 2583 BUS-1 users and 704 BUS-2 users can be connected. Several detector group inputs and/or BUS users can be allocated to one detector group. Logical relationships of the individual detector groups to the object-specific conditions are thus possible. The central control units are mounted in the standard housing type ZG 4. The extension modules are mounted on the back of the housing and interconnected via a flat band cable. In addition to the central control units in the housing type ZG 4, 19” versions are also available. The central control unit in the housing type ZG 4 as well as the 19" versions, are each available with or without an integrated printer. The power supply (option) can be made via one or several power supplies/charger units of 17 Ah to 130 Ah depending on the size of the system. The central control units are easy to program with a PC/laptop via the parameterization software WINFEM Advanced. Remote programming or remote control is also possible in conjunction with a transmission device and WINFEM Advanced, Options/accessories Technical data Rated connection voltage Rated operating voltage U_b Current consumption at U_b, disarmed, w/o extension Environmental class as per VdS Protection class as per DIN 40 050 Operating temperature range Dimensions W x H x D: Housing type ZG 4 19" version Colour: Housing 230 V AC / 50 Hz 12 V DC max. 140 mA II IP 30 -10 °C to +50 °C 580 x 640 x 300 mm 488 x 272 x 110 mm (incl. printer) grey white (similar to RAL 9002) signal grey (similar to RAL 7004) Front Honeywell Security Deutschland Novar GmbH Johannes-Mauthe-Str. 14 D-72458 Albstadt Telefon: +49 (0) 74 31 / 801-0 Telefax: +49 (0) 74 31 / 801-12 20 www.honeywell.com/security/de [email protected] P00169-22-0G0-01 03.2006 · Subject to alteration © 2006 Novar GmbH Optional extension modules 013220.04 Connection module Module with slot for acoustic plug-in card and radio card. Equipped with 4 x 250 V AC / 5 A and 4 x 24 V DC / 1 A relays. 10 programmable 12 V / 50 mA semi-conductor outputs as well as a main and permanent alarm output can be used to actuate the relays or as a semi-conductor output. 013220.05 I/O basic module Module with 32 inputs for connecting one or several conventional detectors or switching elements, e.g. block locks or operating units.Also available are 48 program- mable semi-conductor outputs, 32 of which can be used via programming connectors for clearing detector groups. 013220.11 BUS-1 module Extension module for connecting up to 252 users. 4 independent connections individually protected by fuse are available for BUS-1 users. Up to 63 BUS-1 users are possible per connection. 013220.07 BUS-2 module Extension module for connection BUS-2 users. 4 connections, individually protected by fuse, are available for a total of 64 BUS-2 users. isolated against each other and 013230 Retrofit kit IDC 561-MB256 to IDCU 561-MB256 plus This retrofit kit enables a central control unit 561-MB256 to be retrofitted to a central control unit 561-MB256 . The retrofit kit comprises the computer/connection PCB, adapter PCB for the serial printer, the assembly adapter plate, all necessary mounting and installation material as well as WINFEM Advanced. plus 013330.10 IGIS-LOOP controller Extension module for integrating intrusion detection central control units in the IGIS- LOOP network. The IGIS-LOOP controller is the central module of the IGIS-LOOP security network. If the controllers are connected in a ring, they form the core of the IGIS-LOOP. 013220.06 Keypad module The module enables the connection up to 4 keypad units with a matrix connection (3/4). Note: Max. 25 keypad modules can be used. 013100.08 Relay extension module The relay extension module is equipped with 4 x 250 V AC / 5 A relays as well as 2 slots for group relay cards 070478.The module is not designed for connecting to the I-BUS.The relays are actuated via conventional connections (e.g. programmable semi-conductor outputs). 013220.14 Connection PCB for table-top printer External table-top printers with a parallel interface can be controlled with this PCB. With the PCB, a galvanic separation is possible between the intrusion detection central control unit and the printer although the non-reactive operation of an external printer is guaranteed. Housings Relay extension Printer/printer accessories Power supply/charger units RDT/transmission devices 050055 19" housing type ZG 4 050056 19" housing type ZG 5 050057 19" housing type ZG 6 013118 19" dummy plate 6 HU, signal grey 013119 19" dummy plate 3 HU, signal grey 070478 Group relay card 013900 Alphanumerical thermoprinter 40-digit, with motor-driven spooling 010686.01 Power supply/charger unit 12 V DC / 17 Ah 010690.01 Power supply/charger unit 12 V DC / 32 Ah 010690.02 Power supply/charger unit 12 V DC / 40 Ah 012168 Power supply/charger unit 12 V DC / 80 Ah 012170 Power supply/charger unit 12 V DC /130 Ah 050019 Distributor block 057870 Motherboard DS 6500 057630 Motherboard DS 7500 ISDN 057640 Motherboard DS 7500 ISDN/analogous 057875 Motherboard DS 8500 ISDN 057876 Motherboard DS 8500 ISDN/analogous 057650 Motherboard DS 7600 ISDN 057651 Motherboard DS 7700 ISDN/IP 057920 Motherboard DGA 2400 WINFEM central control unit programming 013901 Paper roll (PU 5 pieces) 013498 Parameterization software WINFEM Advanced 026809 Zero modem cable 013466 Adapter cable with 3-pole plug connector 013467 USB adapter box (USB 1.1-compatible) 013595 WINFEM user; Windows software for programming on user level 013100.10 Connection cable 40 mm / 250 mm 013100.11 Connection cable 400 mm 013100.12 Connection cable 250 mm 013100.13 Connection cable 1000 mm 013100.14 Connection cable 650 mm Connection cables BUS-1 user BUS-2 user BUS-2 operating units 010109.10 1-detector group module 010110.10 2-detector group module 010118 2-detector group module; f.m. version 010111 Universal connection module; s.m. version 010112 Universal connection module; f.m. version 010116 Active distributor module 010125 Key switch - operating unit BUS-1 015128 Radio receiver module 022310.10 Door module 1 022320.10 Door module 2 031540 Hold-up pushbutton module 032211 IDENTLOC evaluation unit 032420 DETEKT 1000 033370/ 033371/ 033372 PIR detector SCM 2000 033401/ 033404/ 033407 PIR detector SCM 3000 041150.10 Switching module 24 V DC / 1 A 041151.10 Switching module 250 V AC / 5 A 042235 Indoor blinking light 043050 Indoor siren module 043060 Piezo indoor siren 062085 Smoke detector base module 013130.10 5 Input module 013131.10 5 Output module 022160.20 IDENT-KEY IK2 evaluation unit 023312.10 IDENT-KEY IK3 evaluation unit 033402/ 033405/ 033408 PIR motion detector SCM 3000 / AÜ 012540 2 x 40-digit LCD operating unit; with flap 012541 2 x 40-digit LCD operating unit; w/o flap 012544 10-DG oper. unit with disabling function 012532 8-DG oper. unit with disabling function 012542 16-DG disabling and display module 012548 16-DG display module 012546 flush mounting kit for 012532, 012541,012542, 012544, 012548 013140 64 DG display terminal 033442 Viewguard DUAL AM BUS-2 033443 Viewguard DUAL BUS-2 Retrofit - central control units -approval pending

Transcript of 561-MB256 plusbells-security.com/new/pdf/mb256_plus_e.pdf · 057640 Motherboard DS 7500...

Page 1: 561-MB256 plusbells-security.com/new/pdf/mb256_plus_e.pdf · 057640 Motherboard DS 7500 ISDN/analogous 057875 Motherboard DS 8500 ISDN 057876 Motherboard DS 8500 ISDN/analogous 057650

561-MB256 plusIntrusion detection central control unit

Performance features

The intrusion detection control unit 561-MB256 isdesigned for use in private and commercial zones and ishighly suitable for setting up medium to large-sizedhazard detection systems.

It complies with the latest guidelines of the VdS SecurityClass C as well as the German Electrical Standards0833, Part 1 and Part 3 of Class 1, Version B.

The standard version of the 561-MB256 has thefollowing performance features:

• 4 conventional detector group inputs

• 63 BUS-1 users - connectable

• 64 BUS-2 users - connectable

• 8 freely programmable semi-conductor outputs

as well as 4 freely programmable relays

• Integrated, monitored alarm signalling device

connections

• Serial and parallel printer interface

With the corresponding extension modules as well asBUS-1 and BUS-2 users, a total of 2048 detector groupscan be realized. When fully equipped with 32 I/Omodules, 1028 conventional inputs (terminating value12.1 kOhm) are available that can be used as inputs fordetectors and switching devices.

plus

plus

• Up to 2048 detector groups can be defined, ofwhich 1028 are conventional detector groups

• Up to 250 main zones can be defined• Up to 2583 BUS-1 users can be connected• Up to 704 BUS-2 users can be connected, of

which max. 50 are operating units• Suitable for police emergency call• 19" version and add-on operating unit• Available with LCD operating unit and printer

depending on version• Programming via USB in conjunction with

PCB/laptop and software package WINFEMAdvanced

• Simple firmware update with Flash-EPROM

• Operator guidance with plain text display• Modular extensible up to max. 32 modules• Automatic maintenance interval indication• IGIS-LOOP and transmission devices can be

integrated (also multiple)• Event memory for 4000 events• Alarm memory - 20 events per main zone

• 1000 IDENT-KEY data carrier codes can bemanaged; up to 250 macros can be defined

• Access with or without code; up to 750 operatingcodes; every operating function can beenabled/disabled individually.

• Technical and fire alarm memory

With maximum upgrading with BUS-1 and BUS-2modules, up to 2583 BUS-1 users and 704 BUS-2 userscan be connected. Several detector group inputs and/orBUS users can be allocated to one detector group.Logical relationships of the individual detector groups tothe object-specific conditions are thus possible.

The central control units are mounted in the standardhousing type ZG 4. The extension modules are mountedon the back of the housing and interconnected via a flatband cable. In addition to the central control units in thehousing type ZG 4, 19” versions are also available. Thecentral control unit in the housing type ZG 4 as well asthe 19" versions, are each available with or without anintegrated printer.

The power supply (option) can be made via one orseveral power supplies/charger units of 17 Ah to 130 Ahdepending on the size of the system.

The central control units are easy to program with aPC/laptop via the parameterization software WINFEMAdvanced. Remote programming or remote control isalso possible in conjunction with a transmission deviceand WINFEM Advanced,

Options/accessories

Technical data

Rated connection voltageRated operating voltage U_bCurrent consumption at U_b, disarmed, w/o extensionEnvironmental class as per VdSProtection class as per DIN 40 050Operating temperature rangeDimensions W x H x D: Housing type ZG 4

19" versionColour: Housing

230 V AC / 50 Hz12 V DCmax. 140 mAIIIP 30-10 °C to +50 °C580 x 640 x 300 mm488 x 272 x 110 mm (incl. printer)grey white (similar to RAL 9002)signal grey (similar to RAL 7004)Front

Honeywell Security DeutschlandNovar GmbHJohannes-Mauthe-Str. 14D-72458 AlbstadtTelefon: +49 (0) 74 31 / 801-0Telefax: +49 (0) 74 31 / 801-12 20www.honeywell.com/security/[email protected]

P00169-22-0G0-0103.2006 · Subject to alteration© 2006 Novar GmbH

Optional extension modules

013220.04Connection moduleModule with slot for acoustic plug-in card and radio card.Equipped with 4 x 250 V AC / 5 A and 4 x 24 V DC / 1 A relays. 10 programmable12 V / 50 mA semi-conductor outputs as well as a main and permanent alarm outputcan be used to actuate the relays or as a semi-conductor output.

013220.05I/O basic moduleModule with 32 inputs for connecting one or several conventional detectors orswitching elements, e.g. block locks or operating units. Also available are 48 program-mable semi-conductor outputs, 32 of which can be used via programming connectorsfor clearing detector groups.

013220.11BUS-1 moduleExtension module for connecting up to 252 users. 4 independent connectionsindividually protected by fuse are available for BUS-1 users. Up to 63 BUS-1 users arepossible per connection.

013220.07BUS-2 moduleExtension module for connection BUS-2 users. 4 connections,

individually protected by fuse, are available for a total of 64 BUS-2 users.isolated against each

other and

013230Retrofit kit IDC 561-MB256 to IDCU 561-MB256 plus

This retrofit kit enables a central control unit 561-MB256 to be retrofitted to a centralcontrol unit 561-MB256 . The retrofit kit comprises the computer/connection PCB,adapter PCB for the serial printer, the assembly adapter plate, all necessary mountingand installation material as well as WINFEM Advanced.

plus

013330.10IGIS-LOOP controllerExtension module for integrating intrusion detection central control units in the IGIS-LOOP network. The IGIS-LOOP controller is the central module of the IGIS-LOOPsecurity network. If the controllers are connected in a ring, they form the core of theIGIS-LOOP.

013220.06Keypad moduleThe module enables the connection up to 4 keypad units with a matrix connection(3/4).Note: Max. 25 keypad modules can be used.

013100.08Relay extension moduleThe relay extension module is equipped with 4 x 250 V AC / 5 A relays as well as 2slots for group relay cards 070478. The module is not designed for connecting to theI-BUS. The relays are actuated via conventional connections (e.g. programmablesemi-conductor outputs).

013220.14Connection PCB for table-top printerExternal table-top printers with a parallel interface can be controlled with this PCB.With the PCB, a galvanic separation is possible between the intrusion detectioncentral control unit and the printer although the non-reactive operation of an externalprinter is guaranteed.

Housings

Relay extension

Printer/printer accessories

Power supply/charger units

RDT/transmission devices

050055 19" housing type ZG 4050056 19" housing type ZG 5050057 19" housing type ZG 6013118 19" dummy plate 6 HU, signal grey013119 19" dummy plate 3 HU, signal grey

070478 Group relay card

013900 Alphanumerical thermoprinter40-digit, with motor-driven spooling

010686.01 Power supply/charger unit 12 V DC / 17 Ah010690.01 Power supply/charger unit 12 V DC / 32 Ah010690.02 Power supply/charger unit 12 V DC / 40 Ah012168 Power supply/charger unit 12 V DC / 80 Ah012170 Power supply/charger unit 12 V DC /130 Ah050019 Distributor block

057870 Motherboard DS 6500057630 Motherboard DS 7500 ISDN057640 Motherboard DS 7500 ISDN/analogous057875 Motherboard DS 8500 ISDN057876 Motherboard DS 8500 ISDN/analogous057650 Motherboard DS 7600 ISDN057651 Motherboard DS 7700 ISDN/IP057920 Motherboard DGA 2400

WINFEM central control unit programming

013901 Paper roll (PU 5 pieces)

013498 Parameterization softwareWINFEM Advanced

026809 Zero modem cable013466 Adapter cable with 3-pole plug connector013467 USB adapter box (USB 1.1-compatible)013595 WINFEM user; Windows software for

programming on user level

013100.10 Connection cable 40 mm / 250 mm013100.11 Connection cable 400 mm013100.12 Connection cable 250 mm013100.13 Connection cable 1000 mm013100.14 Connection cable 650 mm

Connection cables

BUS-1 user

BUS-2 user

BUS-2 operating units

010109.10 1-detector group module010110.10 2-detector group module010118 2-detector group module; f.m. version010111 Universal connection module; s.m. version010112 Universal connection module; f.m. version010116 Active distributor module010125 Key switch - operating unit BUS-1015128 Radio receiver module022310.10 Door module 1022320.10 Door module 2031540 Hold-up pushbutton module032211 IDENTLOC evaluation unit032420 DETEKT 1000033370/033371/033372 PIR detector SCM 2000033401/033404/033407 PIR detector SCM 3000041150.10 Switching module 24 V DC / 1 A041151.10 Switching module 250 V AC / 5 A042235 Indoor blinking light043050 Indoor siren module043060 Piezo indoor siren062085 Smoke detector base module

013130.10 5 Input module013131.10 5 Output module022160.20 IDENT-KEY IK2 evaluation unit023312.10 IDENT-KEY IK3 evaluation unit033402/033405/033408 PIR motion detector SCM 3000 / AÜ

012540 2 x 40-digit LCD operating unit; with flap012541 2 x 40-digit LCD operating unit; w/o flap012544 10-DG oper. unit with disabling function012532 8-DG oper. unit with disabling function012542 16-DG disabling and display module012548 16-DG display module012546 flush mounting kit for 012532, 012541,012542,

012544, 012548013140 64 DG display terminal

033442 Viewguard DUAL AM BUS-2033443 Viewguard DUAL BUS-2

Retrofit - central control units

-approval pending

Page 2: 561-MB256 plusbells-security.com/new/pdf/mb256_plus_e.pdf · 057640 Motherboard DS 7500 ISDN/analogous 057875 Motherboard DS 8500 ISDN 057876 Motherboard DS 8500 ISDN/analogous 057650

013222.10Intrusion detection central control unit 561-MB256 in housing Type ZG 4plus

013223.10Intrusion detection central control unit 561-MB256 in housing type ZG 4,incl. printer

plus

013224.10Intrusion detection central control unit 561-MB256 19" versionplus

013225.10Intrusion detection central control unit 561-MB256 19" version,incl. printer

plus

013228.10Intrusion detection central control unit 561-MB256 19" version,with operating unit

plus

013229.10Intrusion detection central control unit 561-MB256 19" version,with operating unit including printer

plus

Space for 8 options; space for power supply/charger unit; max. space foraccumulator 2 x 65 Ah

Slot for 8 options; space for power supply/charger unit; max. space foraccumulator 2 x 65 Ah

Computer/connection PCB;Housing type ZG 4; front plate 6 HU; dummy plate 6 HU

Computer/connection PCB; thermoprinter 103900; housing Type ZG 4;front plate 6 HU; dummy plate 6 HU

Computer/connection PCB; front plate 6 HU

Computer/connection PCB; thermoprinter 013900; front plate 6 HU

Computer/connection PCB; operating unit 012541; front plate 6 HU

Computer/connection PCB; operating unit 012541; thermoprinter 013900;front plate 6 HU

-approval pending

-approval pending