502 - Netcontrol€¦ · Telegyr 065, 102 Telegyr 800 Applications • Connection of power station...

4
NETCON GW502 Cyber secure communication gateway for the Netcon 500 outstation Highly versatile communication gateway

Transcript of 502 - Netcontrol€¦ · Telegyr 065, 102 Telegyr 800 Applications • Connection of power station...

Page 1: 502 - Netcontrol€¦ · Telegyr 065, 102 Telegyr 800 Applications • Connection of power station RTUs, protection equipment and other serial communication devices to the control

NETCON GW502Cyber secure communication gateway for the Netcon 500 outstation

Highly versatile communication gateway

Page 2: 502 - Netcontrol€¦ · Telegyr 065, 102 Telegyr 800 Applications • Connection of power station RTUs, protection equipment and other serial communication devices to the control

FEATURES Main processor unit for the Netcon 500

Both serial and Ethernet traffic

Traffic prioritising and routing

Bandwidth usage optimisation

Traffic tunneling and encryption

Firewall

Protocol conversions

NETCON GW502Cyber secure communication gateway for the Netcon 500 outstation

Page 3: 502 - Netcontrol€¦ · Telegyr 065, 102 Telegyr 800 Applications • Connection of power station RTUs, protection equipment and other serial communication devices to the control

3

Communication gateway for the Netcon 500 outstation

SEAMLESS SCADA INTEGRATION

The Netcon GW502 is the central processing and communication unit for the Netcon 500 RTU. Its NFE software handles conversions between a wide variety of up-stream and down-stream telecontrol protocols, allowing the seamless integration of different brands of outstations into your SCADA system.

Protocol Seri

al

IP Mas

ter

Slav

e

IEC 61850-8-1 client, ed. 1 & 2

IEC 60870-5-104

IEC 60870-5-104 with NUC exten-sions

NFE-link

Modbus serial/TCP

DNP3.0

IEC 60870-5-101

IEC 60870-5-103

ADLP80

RP570 & ADLP180

RP570 & ADLP180 modem pool

ANSI X3.28 (Allen Bradley)

COMLI

Alstom Courier

Ferranti MKIII

IEC 62056-21

Mobitex

Mobitex radio simulation

Netcon 8830/8080

NettLink

System NM

Nortroll

P&B

Procol

Sinaut ST1

Spacom

Telegyr 065, 102Telegyr 800

Applications

• Connection of power station RTUs, protection equipment and other serial communication devices to the control centre

• Conversion of substation protocols to the SCADA protocol

• Sharing of one substation between two SCADA systems

GPS time synchronisation

SeveralSCADA systems

IEC 61850 relays,IEDs

Netcon 500 OP

LegacyModbus RTU

and DNP3relays

IEC-103, JBUS andSPA relays

WAN

Ethernetswitch

Page 4: 502 - Netcontrol€¦ · Telegyr 065, 102 Telegyr 800 Applications • Connection of power station RTUs, protection equipment and other serial communication devices to the control

M00114-BR-EN-8 © NETCONTROL GROUP 2019 NETCON IS A REGISTERED TRADEMARK OF NETCONTROL GROUP. 44

®

SECURE CONNECTIVITY

The Netcon GW502 provides secure networking thanks to its firewall, VPN and encryption features. It includes a 10/100 Mbps Ethernet switch.

TECHNICAL SPECIFICATIONS

Environmental requirements

• Complies with EN61000-6-2, EN61000-6-4 and EN61000-6-5

• Operating temperature: 0...+70°C*• Storage temperature: −40...+70°C• Relative humidity: 5...95%

Power supply

• Voltage range: 24...48 VDC• Power consumption: < 12 W

Connections

• Dual 10/100Base-TX Ethernet ports• Ethernet switch

– 4 × 10/100Base-TX – 1 × 100Base-FX

• 4 × RS-232 (V.24) serial ports• 2 × RS-485 (V.11) converters, e.g. for GPS receiver • V.24 console port• Rack bus interface• Two memory card slots

– one in front panel for SW updates – one on the circuit board for logging

* Continuous operation beyond +55°C may lead to degradation in MTBF.