50-Ohms-01-2012-200dpi
-
Upload
ariel-martinez-n -
Category
Documents
-
view
68 -
download
2
Transcript of 50-Ohms-01-2012-200dpi
2 Kabelwerk Eupen AG
The foundation of the cable factoryKABELWERK EUPEN AG as manufac-turer of electrical cables goes back to thebeginning of the 20th century. Today thecompany has a staff of 950 people pro-ducing power cables, telecommunicationcables and RF-Cables.
Since broadband transmission becamepossible, KABELWERK EUPEN AG has been involved in the design and manu-facture of coaxial cables.The introduction of Cable Television in1962 was decisive for the start of produc-ing coaxial cables on a larger scale.With the increasing demand for coaxialcables and the intensive R&D to improvecable construction and transmissioncharacteristics, KABELWERK EUPENAG has become today one of the lead-ing manufacturer for coaxial cables inthe World.
Over 50 years of experience in the fieldof RF-Cables, the company constantlydeveloped its extensive manufacturingprocesses bearing in mind the improve-ment of quality.
Since 1993 the company is ISO 9001certified for all its products.
Today the cables and connectors fromKABELWERK EUPEN AG, together is anunbeatable match to guarantee superiorperformances and long service life.
Kabelwerk Eupen AG 3
Contents
Introduction
Introduction to EC3 cables and connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Coaxial cables, connectors, tools & grounding clamps
EC3 Foam Dielectric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61/4” Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101/2” Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127/8” Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-1/4” Hiflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161/4” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181/2” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207/8”A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221-1/4”A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241-5/8”A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262-1/4” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Soldered jumper cables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Accessories for cables
1. Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322. Torque wrench. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333. Grounding clamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344. Fixing clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355. Hoisting grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376. Sealant SIL-744 for connectors with sealant injection . . . . . . . . . . 37
7. Eucaseal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388. Lightning arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409. Weatherproofing tape kit . . . . . . . . . . . . . . . . . . . . . . . 41
Cable packaging information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Technical data, designs and specifications presented inthis catalogue are not binding and are subject to changewithout prior notice.
4 Kabelwerk Eupen AG
EUPEN CABLE USA IEUPEN CABLE USA Incnc..
5181 110th Avenue NorthUnit D, Clearwater, Florida - 33760USA
EUPEN CABLE MEXICO SA EUPEN CABLE MEXICO SA
Avenida Manta 705Lindavista, 07300 Mexico, D.F.MEXICO
EUPEN CABLES FRANCEEUPEN CABLES FRANCE
ZA La Haie Griselle24, rue du 8 Mai 194594470 Boissy St LegerFRANCE
KABELWERK RHENANIA GKABELWERK RHENANIA GmbmbHH
Karl-Kuck-Str. 352078 AachenDEUTSCHLAND
Agencies AmericaCanadaUSA
New JerseyTexas
Guatemala
Agencies AfricaEgyptSouth Africa
Agencies EuropeAustriaBulgariaCzech RepublicFinlandHungaryIrelandItalyNorwayPolandRomaniaRussiaSerbiaSloveniaSpainSwedenTurkeyUkraineUnited Kingdom
Agencies OceaniaAustralia
Agencies AsiaHong KongIndiaKingdom of Saudi ArabiaKuwaitLebanonPakistanSingaporeTaiwan R.O.C.Thailand
Over the world
KABELWERK EUPEN AGKABELWERK EUPEN AGMalmedyer Strasse 9
4700 EupenBELGIUM
Kabelwerk Eupen AG 5
Over the world
attachment of any of the connectors.High quality silver plating is used on allparts in the electrical path, with electro-less nickel plating on all mechanicalparts.They feature superior electrical perfor-mances.
EC3 Cables are offered in sizes rangingfrom 1/4” to 2-1/4”. A full range of typeN, DIN and EIA EC3 Connectors areavailable to complete the package,including hanging and grounding acces-sories, as well as other accessoriesneeded to complete installation.
In addition to the cables in this cata-logue we can provide:
- Phase stabilised, phase measuredcable- Low VSWR microwave versions- Special colours- Cable assemblies
Our quality products are delivered fastand on time, saving time and money.Eupen has a staff of engineers to pro-vide complete technical support for ourproducts and to help you to select thebest cable for your application. We canprovide training to assure the bestinstallation of your system.
Antenna stations in mobile, cellular,microwave and broadcast communica-tion systems require high quality coaxialcables and connectors for very low lossand high power signal transmission.
EC3 Cable from Eupen offers betterelectrical performance and greaterdurability than conventional corrugatedcopper cables. It is the best choice forLTE and other wireless communicationapplications requiring a cable with thelowest loss and best long term dura -bility. The more durable construction ofthe EC3 Cable allows us to offer the bestwarranty in the industry – 12 years.
The electrical specifications of the EC3
Cable are unsurpassed. Every reel isswept for attenuation and return lossbefore it leaves the factory. Return lossis typically 30 dB and guaranteed to beat least 23 dB over the cellular and PCSbands, when the cable is terminatedwith EC3 Connectors. Attenuation speci-fications are the best in the industry.
EC3 Connectors are the easiest attach-ing corrugated copper cable connectorsmade. No soldering is required for the
EUPEN cables and cable
accessories are specifically
designed for the needs of
modern radio communication
systems.
EC3:
Eupen Corrugated Copper Cables
6 Kabelwerk Eupen AG
Our coaxial cable design with lowdensity cellular polyethylene foamdielectric and ring-corrugated copperouter conductor and our 50 years ofexperience in manufacturing thesecables are your guarantee of the supplyof a technically optimal construction,featuring:
- lowest loss- excellent flexibility - excellent RF shielding- very low VSWR- easy and reliable installation ofconnectors
Thanks to intensive R&D, Eupenimproved in 2006 the attenuation of itsmost common sections and launch theultra low loss “A” version for 7/8”,1-1/4” and 1-5/8”.
The cable inner conductor isconstructed from copperclad aluminiumwire, copper tube or corrugated coppertube, depending on the cable size.
EC3
F OA M D I E L E C T R I C
The dielectric is a cellular polyethylenefoam manufactured by a proprietaryprocess using ozone friendly expansiongas. A high foaming ratio guaranteeslow attenuation.The foam dielectric is bonded to theinner conductor by a precoating layer.This layer ensures good adhesion of thedielectric to the inner conductor. It alsopermits easy, clean removal of thedielectric during connector installation.The ring-corrugation of the copperouter conductor captures the dielectricmechanically and ensures good adhe-sion to the dielectric. This constructionprevents relative movement betweenthe inner and the outer conductor due tobending, pulling and temperature varia-tions.
The standard cable construction usesan all-weather and UV-resistant black(or grey) PE jacket, suitable for indoor,outdoor or underground installation.
For applications requiring flame-retar-dance, coaxial cables are available witha flame retardant and halogen free jack-et. This construction meets internation-al standards for flame propagation,such as IEC 60332-1-2, smoke densityIEC 61034-1+2 and acidity of evolvedgases IEC 60754-2.
For very severe installation require-ments, cable constructions with steeltape or wire armouring are available.
EUPEN cables feature innovative design,
careful choice of raw materials, consis-
tent manufacturing and quality assurance
techniques.
The result is a coaxial cable with superior
launched electrical and mechanical
performances.
Test on flammabilitya) Test on flammability of single cables
Test in accordance with: IEC 60332-1-2EN 60332-1-2
b) Test on flammability of cable bundles
Test in accordance with: IEC 60332-3 Cat. CEN 50266-2-4 Cat. C
Test on smoke densityTest in accordance with: IEC 61034-1 and -2
EN 61034-1 and -2
Test on corrosive gas emissionsTest in accordance with: IEC 60754-2
EN 50267-2-2
Test on insulation integrityTest in accordance with: IEC 60331-23
VDE 0472 Part 814
Kabelwerk Eupen AG 7
Halogen Free & Fire resistant
H A L O G E N F R E E a n d
F I R E R E S I S TA N T f e a t u r e s
8 Kabelwerk Eupen AG
Cable type 5042 5082 5092 5228X 5328XProduct reference EC1-50-HF EC2-50-HF EC4-50-HF EC5-50-HF EC6-50-HF
Cable type 5042-HLFR 5082-HLFR 5092-HLFR 5228X-HLFR 5328X-HLFRProduct reference EC1-50-HF-FR EC2-50-HF-FR EC4-50-HF-FR EC5-50-HF-FR EC6-50-HF-FR
CHARACTERISTICSConstructionOuter diameter (mm) 7.5 10.3 13.6 28.0 39.0
MechanicalMinimum bending radius
single bending (cm) 2.5 2.5 3 9 15
Electrical• Relative prop. velocity (%) 82 82 82 88 88
• Nominal attenuation at 20 °C
30 MHz (dB/100m) 3.06 2.28 1.68 0.67 0.47450 MHz (dB/100m) 12.20 9.19 6.96 2.76 1.99960 MHz (dB/100m) 18.16 13.76 10.57 4.19 3.051880 MHz (dB/100m) 26.00 19.85 15.51 6.14 4.512170 MHz (dB/100m) 28.10 21.49 16.86 6.67 4.912400 MHz (dB/100m) 29.68 22.73 17.89 7.08 5.222700 MHz (dB/100m) 31.65 24.27 19.18 7.58 5.61
• Mean power rating at 40 °C ambient temperature
30 MHz (kW) 2.26 3.48 5.66 14.49 22.66450 MHz (kW) 0.57 0.86 1.37 3.51 5.40960 MHz (kW) 0.38 0.58 0.90 2.31 3.531880 MHz (kW) 0.27 0.40 0.61 1.58 2.382170 MHz (kW) 0.25 0.37 0.57 1.45 2.192400 MHz (kW) 0.23 0.35 0.53 1.37 2.062700 MHz (kW) 0.22 0.33 0.50 1.28 1.91
• RF peak power (kW) 3.6 7.2 12.8 90 180
• Cut-off frequency (GHz) 22 15.6 13.2 5.1 3.3
1/4” Hiflex 3/8” Hiflex* 1/2” Hiflex 7/8” Hiflex 1-1/4” Hiflex
Cable with stand
Cable with halogen free and flame retardan
STAN
DARD
HLFR
* Please consult us for availability, as minimum order quantities may apply.** Not qualified for LTE application above 2.3 GHz
Qualified4G
LT E
5062 5088 5128 5168 5228 A 5328 A 5438 A 5528EC1-50 EC2-50 EC4-50 EC4.5-50 EC5-50-A EC6-50-A EC7-50-A EC12-50
5062-HLFR 5088-HLFR 5128-HLFR 5168-HLFR 5228A-HLFR 5328A-HLFR 5438A-HLFR 5528-HLFREC1-50-FR EC2-50-FR EC4-50-FR EC4.5-50-FR EC5-50-A-FR EC6-50-A-FR EC7-50-A-FR EC12-50-FR
9.7 11.8 16.0 21.9 28.0 39.0 50.0 60.0
3 4 7 10 10 20 20 25
82 88 88 88 89 88 89 88
2.32 1.69 1.17 0.81 0.62 0.44 0.36 0.299.38 6.79 4.72 3.29 2.50 1.80 1.47 1.2714.05 10.14 7.07 4.94 3.75 2.72 2.23 1.9920.27 14.59 10.20 7.16 5.43 3.98 3.25 3.0321.95 15.79 11.04 7.76 5.88 4.32 3.53 3.3223.22 16.69 11.68 8.22 6.22 4.58 3.74 -24.81 17.82 12.48 8.79 6.65 4.91 4.01 -
3.24 4.11 6.74 9.27 14.60 21.24 28.27 40.860.80 1.02 1.67 2.28 3.60 5.17 6.88 9.300.54 0.68 1.12 1.52 2.40 3.42 4.55 5.930.37 0.48 0.77 1.05 1.66 2.34 3.12 3.900.34 0.44 0.71 0.96 1.53 2.15 2.87 3.560.32 0.42 0.68 0.91 1.45 2.03 2.71 -0.30 0.39 0.63 0.85 1.35 1.90 2.53 -
6.9 11 25.6 62 86 184 302 462
18.6 14.2 9.8 6.5 5.1 3.7 2.8 2.3
Kabelwerk Eupen AG 9
1/4” 3/8” * 1/2” 5/8” * 7/8”A 1-1/4”A 1-5/8”A 2-1/4” *
dard jacket - halogen free in acc. with IEC 60754
nt jacket in acc. with IEC 60754-2, 60332-1-2, 60332-3 Cat. C & 61034-1+2
7/8“ Foam-DielectricFoam-Dielectric
Ultra Low Loss Ultra Low Loss Ultra Low Loss
**
5042 HLFRSTANDARD
Cable type : 5042Reference : EC1-50-HFCable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5042-HLFRReference : EC1-50-HF-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1.5
• Nominal capacity (pF/m) 80
• Relative propagation velocity (%) 82
• Inductance (µH/m) 0.203
• DC-resistance at 20 °C- inner conductor (Ω/km) 9.2- outer conductor (Ω/km) 4.4
• RF peak voltage (kV) 0.6
• RF peak power (kW) 3.6
• Cut-off-frequency (GHz) 22
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 1.76 3.9320 2.49 2.7730 3.06 2.2680 5.03 1.37100 5.63 1.23150 6.93 1.00200 8.03 0.86300 9.89 0.70400 11.48 0.60450 12.20 0.57500 12.89 0.54600 14.18 0.49700 15.37 0.45800 16.49 0.42894 17.49 0.39960 18.16 0.381000 18.56 0.371500 23.03 0.301700 24.63 0.281800 25.40 0.271880 26.00 0.272000 26.89 0.262170 28.10 0.252200 28.31 0.242300 29.00 0.242400 29.68 0.232500 30.35 0.232700 31.65 0.223000 33.53 0.214000 39.31 0.186000 49.36 0.14
Construction
• Inner conductorMaterial copper clad aluminium wireDiameter (mm) 1.9
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 4.6
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 6.4
• JacketMaterial black polyethyleneThickness (mm) 0.55Diameter (mm) 7.5
Mechanical
• Minimum bending radiusa) single bending (cm) 2.5b) 15 repeated bends (cm) 2.5
• Maximum pulling strength (daN) 30
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing -
• Flat plate crush resistance (kg/mm) 1.8
• Bending moment (Nm) 1.1
• Approximate weight[2] (kg/km) 83 / 88
CHARACTERISTICS
1/4” Hiflex
10 Kabelwerk Eupen AG
[1] a = 0.552b = 0.0011∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
SPTC50B14X
NM50BL14XNF50P14X
Kabelwerk Eupen AG 11
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥34* ≥34*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1 ≤1• Inner contact resistance (mΩ) ≤1.5 ≤1.5• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >400** >600
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy• Dielectric TPX/PTFE TPX• Gaskets High quality silicone
* ≥30 for right angle connector** >250 for right angle connector
CONNECTORS & TOOLS
ACCESSORIES
Description Reference
• Fixing clamps see page 35
• Additional weatherproofing see page 41
Reference Description
NM50B14X N male, with silicone gasketNF50B14X N female, with silicone gasketNF50P14X N female, with silicone gasket, panel mountNM50BL14X N male, right angle, with silicone gasket716MB14X 7-16 DIN male, with silicone gasket716FP14X 7-16 DIN female, with silicone gasket, panel mountSPTC50B14X Cable preparation tool
Cutting knife Spare parts for cable preparation toolsPeeling knife (Refer to installation instructions of the tool)
NM50B14X716MB14X
1/4” Hiflex
5092 HLFRSTANDARD
Cable type : 5092Reference : EC4-50-HFCable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5092-HLFRReference : EC4-50-HF-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 82
• Relative propagation velocity (%) 82
• Inductance (µH/m) 0.203
• DC-resistance at 20 °C- inner conductor (Ω/km) 2.65- outer conductor (Ω/km) 3.05
• RF peak voltage (kV) 1.1
• RF peak power (kW) 12.8
• Cut-off-frequency (GHz) 13.2
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.96 9.9020 1.37 6.9630 1.68 5.6680 2.79 3.42100 3.13 3.04150 3.88 2.46200 4.51 2.11300 5.60 1.70400 6.53 1.46450 6.96 1.37500 7.38 1.29600 8.15 1.17700 8.87 1.07800 9.55 1.00894 10.16 0.94960 10.57 0.901000 10.82 0.881500 13.62 0.701700 14.63 0.651800 15.12 0.631880 15.51 0.612000 16.08 0.592170 16.86 0.572200 17.00 0.562300 17.45 0.552400 17.89 0.532500 18.33 0.522700 19.18 0.503000 20.42 0.474000 24.29 0.396000 31.21 0.31
Construction
• Inner conductorMaterial copper clad aluminium wireDiameter (mm) 3.55
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 9.0
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 12.2
• JacketMaterial black polyethyleneThickness (mm) 0.7Diameter (mm) 13.6
Mechanical
• Minimum bending radiusa) single bending (cm) 3b) 15 repeated bends (cm) 3
• Maximum pulling strength (daN) 70
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 0.5
• Flat plate crush resistance (kg/mm) 2.05
• Bending moment (Nm) 2.2
• Approximate weight[2] (kg/km) 193 / 205
CHARACTERISTICS
1/2” Hiflex
12 Kabelwerk Eupen AG
[1] a = 0.30018b = 0.001327∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
Kabelwerk Eupen AG 13
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥34* ≥34*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1 ≤1• Inner contact resistance (mΩ) ≤1 ≤1• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >400 >700
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy• Dielectric TPX/PTFE• Gaskets High quality silicone
* ≥30 for right angle connector
CONNECTORS & TOOLS
ACCESSORIES
Description Reference
• Grounding clamp with normal outlet GCS12X
• Fixing clamps see page 35
• Additional weatherproofing see page 41
Reference Description
716MB12X 7-16 DIN male, with silicone gasket716FB12X 7-16 DIN female, with silicone gasket716MBL12X 7-16 DIN male, right angle, with silicone gasketNM50B12X N male, with silicone gasketNF50B12X N female, with silicone gasketNM50BL12X N male, right angle, with silicone gasketSPTC50B12X Cable preparation tool for straight connectors SPTC50BL12X Cable preparation tool for right angle connectors
Cutting knife Spare parts for cable preparation toolsPeeling knife (Refer to installation instructions of the tool)
NF50B12X 716MB12X NM50BL12X716MBL12X
SPTC50B12X
GCS12X
1/2” Hiflex
SPTC50BL12X
5228X HLFRSTANDARD
Cable type : 5228XReference : EC5-50-HFCable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5228X-HLFRReference : EC5-50-HF-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 76
• Relative propagation velocity (%) 88
• Inductance (µH/m) 0.189
• DC-resistance at 20 °C- inner conductor (Ω/km) 2.5- outer conductor (Ω/km) 1.02
• RF peak voltage (kV) 3.0
• RF peak power (kW) 90
• Cut-off-frequency (GHz) 5.1
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.38 25.3420 0.54 17.8230 0.67 14.4980 1.11 8.74100 1.24 7.79150 1.54 6.30200 1.79 5.41300 2.22 4.36400 2.59 3.74450 2.76 3.51500 2.92 3.31600 3.23 3.00700 3.51 2.75800 3.78 2.56894 4.02 2.40960 4.19 2.311000 4.28 2.261500 5.39 1.801700 5.79 1.671800 5.98 1.621880 6.14 1.582000 6.36 1.522170 6.67 1.452200 6.72 1.442300 6.90 1.402400 7.08 1.372500 7.25 1.332700 7.58 1.283000 8.07 1.204000 9.60 1.016000 - -
Construction
• Inner conductorMaterial corrugated copper tubeDiameter (mm) 9.4
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 23.4
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 25.0
• JacketMaterial black polyethyleneThickness (mm) 1.4Diameter (mm) 28.0
Mechanical
• Minimum bending radiusa) single bending (cm) 9b) 15 repeated bends (cm) 12.5
• Maximum pulling strength (daN) 130
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 1.2
• Flat plate crush resistance (kg/mm) 1.7
• Bending moment (Nm) 8.4
• Approximate weight[2] (kg/km) 475 / 525
CHARACTERISTICS
7/8” Hiflex
14 Kabelwerk Eupen AG
[1] a = 0.11905b = 0.000518∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectorsElectrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥34 ≥34• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤0.7 ≤0.7• Inner contact resistance (mΩ) ≤1 ≤1• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >400 >1000
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric PTFE TPX• Gaskets High quality silicone
CONNECTORS & TOOL
ACCESSORIES
Description Reference
• Grounding clamp with parallel outlet GCS78PAR
• Fixing clamps see page 35
• Additional weatherproofing see page 41
• Lace-up hoisting grip HG-78Pre-laced hoisting grip HG-78-L
see page 37
716FV78M716FA78M
SPTC50AV78X
7/8” Hiflex
Reference Description
716MV78M 7-16 DIN male, O-Ring716FV78M 7-16 DIN female, O-Ring716MA78M 7-16 DIN male, Sealant injection716FA78M 7-16 DIN female, Sealant injectionNM50V78M N male, O-RingNF50V78M N female, O-RingSPTC50AV78X Cable preparation tool
Inner ring Spare parts for cable preparation toolOuter ring (Refer to installation instructions of the tool)Spring Cutting knife Peeling knife Flaring knife
SIL-744 90ml Sealant for connectors using sealant injectionSIL-744 310 ml Sealant for connectors using sealant injection
Rem.: • Sealant for connectors using the sealant injection method must be purchased separately.
GCS78PAR
Kabelwerk Eupen AG 15
5328X HLFRSTANDARD
Cable type : 5328XReference : EC6-50-HFCable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5328X-HLFRReference : EC6-50-HF-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 76
• Relative propagation velocity (%) 88
• Inductance (µH/m) 0.189
• DC-resistance at 20 °C- inner conductor (Ω/km) 1.95- outer conductor (Ω/km) 0.63
• RF peak voltage (kV) 4.3
• RF peak power (kW) 180
• Cut-off-frequency (GHz) 3.3
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.27 39.7320 0.38 27.9030 0.47 22.6680 0.79 13.62100 0.89 12.12150 1.10 9.78200 1.28 8.39300 1.59 6.74400 1.86 5.76450 1.99 5.40500 2.11 5.09600 2.33 4.60700 2.55 4.22800 2.74 3.91894 2.92 3.67960 3.05 3.531000 3.12 3.441500 3.94 2.721700 4.25 2.531800 4.39 2.441880 4.51 2.382000 4.68 2.302170 4.91 2.192200 4.95 2.172300 5.09 2.112400 5.22 2.062500 5.35 2.012700 5.61 1.913000 5.98 1.794000 - -6000 - -
Construction
• Inner conductorMaterial corrugated copper tubeDiameter (mm) 13.6
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 33.5
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 36.0
• JacketMaterial black polyethyleneThickness (mm) 1.5Diameter (mm) 39.0
Mechanical
• Minimum bending radiusa) single bending (cm) 15b) 15 repeated bends (cm) 25
• Maximum pulling strength (daN) 190
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 1.4
• Flat plate crush resistance (kg/mm) 3.4
• Bending moment (Nm) 25
• Approximate weight[2] (kg/km) 754
CHARACTERISTICS
1-1/4” Hiflex
16 Kabelwerk Eupen AG
[1] a = 0.084b = 0.000461∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
Kabelwerk Eupen AG 17
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥35 ≥35*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1.0• Inner contact resistance (mΩ) ≤1.0• PIM ratio (2 x 20 W carrier) (dBc) ≤-155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >1000
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric TPX• Gaskets High quality silicone
* sealant injection type: ≥34
CONNECTORS & TOOL
ACCESSORIES
Description Reference
• Grounding clamp with parallel outlet GCS114PAR
• Fixing clamps see page 35
• Additional weatherproofing see page 41
• Lace-up hoisting grip HG-114Pre-laced hoisting grip HG-114-L
see page 37
Reference Description
716MV114N1 7-16 DIN male, O-Ring716FV114N1 7-16 DIN female, O-Ring716MA114M 7-16 DIN male, Sealant injection716FA114M 7-16 DIN female, Sealant injectionNM50V114N1 N male, O-RingNF50V114N1 N female, O-RingSPTC50AV114X Cable preparation tool
Inner ring Spare parts for cable preparation toolOuter ring (Refer to installation instructions of the tool)SpringCutting knifePeeling knife
SIL-744 90ml Sealant for connectors using sealant injectionSIL-744 310 ml Sealant for connectors using sealant injection
Rem.: • Sealant for connectors using the sealant injection method must be purchased separately.
SPTC50AV114X
GCS114PAR
1-1/4” Hiflex
716FV114N1NF50V114N1
5062 HLFRSTANDARD
Cable type : 5062Reference : EC1-50Cable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5062-HLFRReference : EC1-50-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 82
• Relative propagation velocity (%) 82
• Inductance (µH/m) 0.203
• DC-resistance at 20 °C- inner conductor (Ω/km) 5.85- outer conductor (Ω/km) 3.3
• RF peak voltage (kV) 0.8
• RF peak power (kW) 6.9
• Cut-off-frequency (GHz) 18.6
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 1.33 5.6420 1.89 3.9830 2.32 3.2480 3.83 1.96100 4.29 1.75150 5.29 1.42200 6.14 1.23300 7.58 0.99400 8.81 0.85450 9.38 0.80500 9.91 0.76600 10.92 0.69700 11.86 0.63800 12.73 0.59894 13.52 0.56960 14.05 0.541000 14.36 0.521500 17.90 0.421700 19.18 0.391800 19.79 0.381880 20.27 0.372000 20.98 0.362170 21.95 0.342200 22.12 0.342300 22.68 0.332400 23.22 0.322500 23.76 0.322700 24.81 0.303000 26.33 0.294000 31.02 0.246000 39.25 0.19
Construction
• Inner conductorMaterial copper clad aluminium wireDiameter (mm) 2.4
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 6.5
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 7.5
• JacketMaterial black polyethyleneThickness (mm) 1.1Diameter (mm) 9.7
Mechanical
• Minimum bending radiusa) single bending (cm) 3b) 15 repeated bends (cm) 8
• Maximum pulling strength (daN) 40
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing -
• Flat plate crush resistance (kg/mm) 0.8
• Bending moment (Nm) 1.5
• Approximate weight[2] (kg/km) 111 / 124
CHARACTERISTICS
1/4”
18 Kabelwerk Eupen AG
[1] a = 0.41769b = 0.00115∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
Kabelwerk Eupen AG 19
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥34* ≥34*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1 ≤1• Inner contact resistance (mΩ) ≤1.5 ≤1.5• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30 • Cable retention (N) >400 >700
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric TPX/PTFE• Gaskets High quality silicone
* ≥30 for right angle connector
CONNECTORS & TOOLS
ACCESSORIES
Description Reference
• Grounding clamp with normal outlet GCS14
• Fixing clamps see page 35
• Additional weatherproofing see page 41
Reference Description
716MA14 7-16 DIN male, O-Ring716FA14 7-16 DIN female, O-RingNM50A14 N male, O-RingNF50A14 N female, O-RingNM50AL14 N male, right angle, O-RingSPTC50A14 Cable preparation tool
Cutting knife Spare parts for cable preparation toolsPeeling knife (Refer to installation instructions of the tool)
NM50AL14NF50A14
GCS14
1/4”
SPTC50A14
5128 HLFRSTANDARD
Cable type : 5128Reference : EC4-50Cable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5128-HLFRReference : EC4-50-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 76
• Relative propagation velocity (%) 88
• Inductance (µH/m) 0.189
• DC-resistance at 20 °C- inner conductor (Ω/km) 1.48- outer conductor (Ω/km) 2.04
• RF peak voltage (kV) 1.6
• RF peak power (kW) 25.6
• Cut-off-frequency (GHz) 9.8
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.67 11.7520 0.95 8.2830 1.17 6.7480 1.93 4.09100 2.16 3.65150 2.66 2.96200 3.09 2.55300 3.82 2.07400 4.44 1.78450 4.72 1.67500 4.99 1.58600 5.50 1.43700 5.97 1.32800 6.41 1.23894 6.80 1.16960 7.07 1.121000 7.23 1.091500 9.01 0.881700 9.65 0.821800 9.96 0.791880 10.20 0.772000 10.55 0.752170 11.04 0.712200 11.13 0.712300 11.41 0.692400 11.68 0.682500 11.95 0.662700 12.48 0.633000 13.24 0.604000 15.59 0.516000 19.73 0.40
Construction
• Inner conductorMaterial copper clad aluminium wireDiameter (mm) 4.8
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 12.4
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 13.8
• JacketMaterial black polyethyleneThickness (mm) 1.1Diameter (mm) 16.0
Mechanical
• Minimum bending radiusa) single bending (cm) 7b) 15 repeated bends (cm) 12
• Maximum pulling strength (daN) 100
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 1
• Flat plate crush resistance (kg/mm) 1.9
• Bending moment (Nm) 3.5
• Approximate weight[2] (kg/km) 231 / 253
CHARACTERISTICS
1/2”
20 Kabelwerk Eupen AG
[1] a = 0.2105b = 0.00057∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
716MAL12
Kabelwerk Eupen AG 21
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥34* ≥34*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1 ≤1• Inner contact resistance (mΩ) ≤1 ≤1• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >500** >1000***
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric TPX/PTFE TPX• Gaskets High quality silicone
* ≥30 for right angle connector** >400 for N-right angle connector*** >700 for 7-16 right angle connector
CONNECTORS & TOOL
ACCESSORIES
Description Reference
• Grounding clamp with parallel outlet GCS12PAR
• Fixing clamps see page 35
• Additional weatherproofing see page 41
• Lace-up hoisting grip HG-12Pre-laced hoisting grip HG-12-L
see page 37
Reference Description
716MV12 7-16 DIN male, O-Ring716FV12 7-16 DIN female, O-Ring716MA12 7-16 DIN male, Sealant injection716FA12 7-16 DIN female, Sealant injection716MVL12 7-16 DIN male, right angle, O-Ring716MAL12 7-16 DIN male, right angle, Sealant injectionNM50V12 N male, O-RingNF50V12 N female, O-RingNM50A12 N male, Sealant injectionNF50A12 N female, Sealant injectionNM50VL12 N male, right angle, O-RingNM50AL12 N male, right angle, Sealant injectionSPTC50AV12 Cable preparation tool
Cutting knife Spare parts for cable preparation toolPeeling knife (Refer to installation instructions of the tool)
SIL-744 90ml Sealant for connectors using sealant injectionSIL-744 310 ml Sealant for connectors using sealant injection
Rem.: • Sealant for connectors using the sealant injection method must be purchased separately.
716FV12NF50A12
SPTC50AV12
1/2”
GCS12PAR
HLFR
22 Kabelwerk Eupen AG
5228 ASTANDARD
Cable type : 5228 AReference : EC5-50-ACable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5228A-HLFRReference : EC5-50-A-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 75
• Relative propagation velocity (%) 89
• Inductance (µH/m) 0.187
• DC-resistance at 20 °C- inner conductor (Ω/km) 1.55- outer conductor (Ω/km) 1.31
• RF peak voltage (kV) 2.9
• RF peak power (kW) 86
• Cut-off-frequency (GHz) 5.1
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.35 25.4620 0.50 17.9330 0.62 14.6080 1.02 8.85100 1.14 7.89150 1.41 6.40200 1.63 5.51300 2.02 4.46400 2.35 3.83450 2.50 3.60500 2.64 3.41600 2.91 3.09700 3.16 2.85800 3.40 2.65894 3.61 2.49960 3.75 2.401000 3.83 2.351500 4.79 1.881700 5.13 1.751800 5.30 1.701880 5.43 1.662000 5.62 1.602170 5.88 1.532200 5.92 1.522300 6.07 1.482400 6.22 1.452500 6.37 1.412700 6.65 1.353000 7.06 1.274000 8.33 1.086000 - -
Construction
• Inner conductorMaterial smooth copper tubeDiameter (mm) 9.2
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 23.5
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 25.0
• JacketMaterial black polyethyleneThickness (mm) 1.4Diameter (mm) 28.0
Mechanical
• Minimum bending radiusa) single bending (cm) 10b) 15 repeated bends (cm) 25
• Maximum pulling strength (daN) 140
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 1.2
• Flat Plate Crush resistance (kg/mm) 1.4
• Bending moment (Nm) 11.6
• Approximate weight[2] (kg/km) 436 / 486
CHARACTERISTICS
7/8” AUltra Low Loss
[1] a = 0.1107b = 0.000333∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectorsElectrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥35 ≥35*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1.0• Inner contact resistance (mΩ) ≤1.0• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >1000
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric TPX• Gaskets High quality silicone
* sealant injection type: ≥34
CONNECTORS & TOOL
ACCESSORIES
Description Reference
• Grounding clamp with parallel outlet GCS78PAR
• Fixing clamps see page 35
• Additional weatherproofing see page 41
• Lace-up hoisting grip HG-78Pre-laced hoisting grip HG-78-L
see page 37
Reference Description
716MV78N1 7-16 DIN male, O-Ring716FV78N1 7-16 DIN female, O-Ring716MA78MA 7-16 DIN male, Sealant injection716FA78MA 7-16 DIN female, Sealant injectionNM50V78N1 N male, O-RingNF50V78N1 N female, O-RingSPTC50AV78M Cable preparation tool
Inner ring Spare parts for cable preparation toolOuter ring (Refer to installation instructions of the tool)SpringCutting knifePeeling knifeFlaring knife
SIL-744 90ml Sealant for connectors using sealant injectionSIL-744 310 ml Sealant for connectors using sealant injection
Rem.: • Sealant for connectors using the sealant injection method must be purchased separately.
• EIA connectors available on request.
716FV78N1NM50V78N1
SPTC50AV78M
GCS78PAR
Kabelwerk Eupen AG 23
7/8” A
5328 A HLFRSTANDARD
Cable type : 5328 AReference : EC6-50-ACable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5328 A-HLFRReference : EC6-50-A-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 76
• Relative propagation velocity (%) 88
• Inductance (µH/m) 0.189
• DC-resistance at 20 °C- inner conductor (Ω/km) 0.95- outer conductor (Ω/km) 0.63
• RF peak voltage (kV) 4.3
• RF peak power (kW) 184
• Cut-off-frequency (GHz) 3.7
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.25 37.1320 0.36 26.1230 0.44 21.2480 0.73 12.84100 0.81 11.44150 1.01 9.26200 1.17 7.96300 1.45 6.42400 1.69 5.51450 1.80 5.17500 1.91 4.88600 2.10 4.42700 2.29 4.07800 2.46 3.78894 2.62 3.56960 2.72 3.421000 2.79 3.341500 3.50 2.661700 3.76 2.481800 3.88 2.401880 3.98 2.342000 4.12 2.262170 4.32 2.152200 4.35 2.142300 4.47 2.082400 4.58 2.032500 4.69 1.982700 4.91 1.903000 5.22 1.784000 - -6000 - -
Construction
• Inner conductorMaterial smooth copper tubeDiameter (mm) 13.0
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 33.5
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 36.0
• JacketMaterial black polyethyleneThickness (mm) 1.5Diameter (mm) 39.0
Mechanical
• Minimum bending radiusa) single bending (cm) 20b) 15 repeated bends (cm) 35
• Maximum pulling strength (daN) 240
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 1.4
• Flat plate crush resistance (kg/mm) 2.4
• Bending moment (Nm) 30
• Approximate weight[2] (kg/km) 803 / 889
CHARACTERISTICS
1-1/4” A
24 Kabelwerk Eupen AG
Ultra Low Loss
[1] a = 0.0783b = 0.00031∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
Kabelwerk Eupen AG 25
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 3 GHz (dB) ≥35 ≥35*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1.0• Inner contact resistance (mΩ) ≤1.0• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >1000
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric TPX• Gaskets High quality silicone
* sealant injection type: ≥34
CONNECTORS & TOOL
ACCESSORIES
Description Reference
• Grounding clamp with parallel outlet GCS114PAR
• Fixing clamps see page 35
• Additional weatherproofing see page 41
• Lace-up hoisting grip HG-114Pre-laced hoisting grip HG-114-L
see page 37
Reference Description
716MV114N1 7-16 DIN male, O-Ring716FV114N1 7-16 DIN female, O-Ring716MA114M 7-16 DIN male, Sealant injection716FA114M 7-16 DIN female, Sealant injectionNM50V114N1 N male, O-RingNF50V114N1 N female, O-RingSPTC50AV114M Cable preparation tool
Inner ring Spare parts for cable preparation toolOuter ring (Refer to installation instructions of the tool)SpringCutting knifePeeling knife
SIL-744 90ml Sealant for connectors using sealant injectionSIL-744 310 ml Sealant for connectors using sealant injection
Rem.: • Sealant for connectors using the sealant injection method must be purchased separately.
• EIA connectors available on request.
716FV114N1NF50V114N1
SPTC50AV114M
GCS114PAR
1-1/4” A
5438 A HLFRSTANDARD
Cable type : 5438 AReference : EC7-50-ACable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5438 A-HLFRReference : EC7-50-A-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 75
• Relative propagation velocity (%) 89
• Inductance (µH/m) 0.187
• DC-resistance at 20 °C- inner conductor (Ω/km) 1.37- outer conductor (Ω/km) 0.5
• RF peak voltage (kV) 5.5
• RF peak power (kW) 302
• Cut-off-frequency (GHz) 2.8
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.20 49.4220 0.29 34.7630 0.36 28.2780 0.59 17.09100 0.67 15.22150 0.82 12.32200 0.96 10.60300 1.18 8.55400 1.38 7.33450 1.47 6.88500 1.56 6.50600 1.72 5.89700 1.87 5.41800 2.01 5.03894 2.14 4.73960 2.23 4.551000 2.28 4.451500 2.86 3.541700 3.07 3.301800 3.17 3.191880 3.25 3.122000 3.37 3.012170 3.53 2.872200 3.56 2.852300 3.65 2.772400 3.74 2.712500 3.83 2.642700 4.01 2.533000 - -4000 - -6000 - -
Construction
• Inner conductorMaterial corrugated copper tubeDiameter (mm) 17.7
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 43.0
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 46.6
• JacketMaterial black polyethyleneThickness (mm) 1.7Diameter (mm) 50.0
Mechanical
• Minimum bending radiusa) single bending (cm) 20b) 15 repeated bends (cm) 40
• Maximum pulling strength (daN) 250
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 1.5
• Flat plate crush resistance (kg/mm) 2.4
• Bending moment (Nm) 42
• Approximate weight[2] (kg/km) 1019 / 1131
CHARACTERISTICS
1-5/8”A
26 Kabelwerk Eupen AG
Ultra Low Loss
[1] a = 0.064b = 0.000253∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
Kabelwerk Eupen AG 27
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 2.7 GHz (dB) ≥35 ≥35*• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤1.0• Inner contact resistance (mΩ) ≤1.0• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >1500
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric PTFE TPX• Gaskets High quality silicone
* sealant injection type: ≥34
CONNECTORS & TOOL
ACCESSORIES
Description Reference
• Grounding clamps with parallel outlet GCS158PAR
• Fixing clamps see page 35
• Additional weatherproofing see page 41
• Lace-up hoisting grip HG-158Pre-laced hoisting grip HG-158-L
see page 37
Reference Description
716MV158N1 7-16 DIN male, O-Ring716FV158N1 7-16 DIN female, O-Ring716MA158MPA 7-16 DIN male, Sealant injection716FA158MPA 7-16 DIN female, Sealant injectionNM50V158N1 N male, O-RingNF50V158N1 N female, O-RingSPTC50AV158M Cable preparation tool
Inner ring Spare parts for cable preparation toolOuter ring (Refer to installation instructions of the tool)SpringCutting knifePeeling knife
SIL-744 90 ml Sealant for connectors using sealant injectionSIL-744 310 ml Sealant for connectors using sealant injection
Rem.: • Sealant for connectors using the sealant injection method must be purchased separately.
• EIA connectors available on request.
716MV158N1NF50V158N1
SPTC50AV158M
GCS158PAR
1-5/8”A
5528 HLFRSTANDARD
Cable type : 5528Reference : EC12-50Cable with standard UV resistant PE jacket, halogen free accordingto IEC 60754
FLAME RETARDANT
Cable type : 5528-HLFRReference : EC12-50-FRCable with UV resistant, halogen free, low smoke, flame retardantjacket according to IEC 60754-2, IEC 60332-1-2, IEC 60332-3Cat. C and IEC 61034-1+2
Electrical
• Characteristic impedance (Ω) 50 ±1
• Nominal capacity (pF/m) 76
• Relative propagation velocity (%) 88
• Inductance (µH/m) 0.189
• DC-resistance at 20 °C- inner conductor (Ω/km) 0.55- outer conductor (Ω/km) 0.25
• RF peak voltage (kV) 6.8
• RF peak power (kW) 462
• Cut-off-frequency (GHz) 2.3
• Insulation resistance (MΩ.km) >>5000
• Attenuation[1] and power ratingFrequency Attenuation at 20 °C[3] Mean power rating[4]
(MHz) (dB/100m) (kW)
10 0.16 72.1920 0.23 50.4730 0.29 40.8680 0.49 24.30100 0.55 21.55150 0.68 17.28200 0.80 14.74300 1.01 11.74400 1.19 9.96450 1.27 9.30500 1.35 8.75600 1.50 7.86700 1.65 7.18800 1.78 6.62894 1.91 6.20960 1.99 5.931000 2.04 5.791500 2.63 4.501700 2.84 4.161800 2.95 4.011880 3.03 3.902000 3.15 3.752170 3.32 3.562200 3.35 3.532300 - -2400 - -2500 - -3000 - -4000 - -6000 - -
Construction
• Inner conductorMaterial corrugated copper tubeDiameter (mm) 21.0
• DielectricMaterial gas-injected cellular polyethyleneDiameter (mm) 52.0
• Outer conductorMaterial corrugated copper tubeDiameter (mm) 56.0
• JacketMaterial black polyethyleneThickness (mm) 2.0Diameter (mm) 60.0
Mechanical
• Minimum bending radiusa) single bending (cm) 25b) 15 repeated bends (cm) 55
• Maximum pulling strength (daN) 300
• Recommended temperature range- Storage -70 to +85 °C- Installation -40 to +60 °C- Operation -55 to +85 °C
• Maximum length per hoisting grip (m) 70
• Maximum hanger spacing 1.8
• Flat Plate Crush resistance (kg/mm) 4.8
• Bending moment (kg/km) 90
• Approximate weight[2] (kg/km) 1838
CHARACTERISTICS
2-1/4”
28 Kabelwerk Eupen AG
[1] a = 0.05035b = 0.00045∝(ƒ) = a . √ f + b . f [dB/100m]
[2] Standard PE jacket[3] Nominal values[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Specification of N-connectors 7-16 connectors
Kabelwerk Eupen AG 29
Electrical
• Nominal impedance (Ω) 50 50• Return loss at 2.3 GHz (dB) ≥32 ≥32• Insulation resistance (GΩ) ≥5 ≥10• Test voltage (at sea level) 2.5 4
(kV rms, 50 Hz)• Working voltage (at sea level) 1 2.7
(kV rms, 50 Hz)• Screening effectiveness >128 >128
up to 1 GHz (dB)• Outer contact resistance (mΩ) ≤0.5 ≤0.5• Inner contact resistance (mΩ) ≤1 ≤1• PIM ratio (2 x 20 W carrier) (dBc) ≤ -155
(Typical -163)
Mechanical
• Torque on coupling nut (Nm) 8 30• Cable retention (N) >400 >1000
Environmental
• Temperature range (°C) -40 to +85• Degree of protection (humidity) IP67/IP68 (mated connectors)
Materials
• External parts Passivated silver plated or electroless nickel plated brass
• Outer contact Passivated silver plated brass• Inner contact Passivated silver plated
high-strength copper alloy and brass• Dielectric TPX/PTFE• Gaskets High quality silicone
CONNECTORS & TOOL
ACCESSORIES
Type Reference Description
• Grounding clamp with parallel outlet GCS214PAR
• Fixing clamps see page 35
• Additional Weatherproofing see page 41
Reference Description
716MV214 7-16 DIN male, O-Ring716FV214 7-16 DIN female, O-RingNM50V214 N male, O-RingNF50V214 N female, O-RingSG 214 Saw guideSIL-744 90ml Sealant for connectors using sealant injectionSIL-744 310 ml Sealant for connectors using sealant injection
Rem.: • Sealant for connectors using the sealant injection method must be purchased separately.
716MV214NF50V214
SG214
2-1/4”
GCS214PAR
30 Kabelwerk Eupen AG
EUPEN offers jumper cables with 1/2” Hiflex cable (5092 /EC4-50-HF) or 1/2” standard cable (5128 / EC4-50) with sol-dered DIN 7-16 or N type straight and right angle connectors.All metal contact parts are silver plated. They are designedfor watertight applications and optimised jumper cable perfor-mances.
Features
• excellent return loss values• very low bending radius:• 30 mm for 1/2” Hiflex (5092)• 70 mm for 1/2” standard (5128) for single bending(125 mm for repeated bendings)
• very low level of 3rd order intermodulation products • easy, fast and reliable installation• water tightness according to IP67/IP68 (mated connectors)
• longitudinal water tightness is providedby the special connector design (O-Ring in connector head)
• the overmolding of the connector provides an additional mechanical protection
Product reference
EC4-vv-S-www-XYZXYZ
EC4 = 1/2” cable (5128)vv = HF for Hiflex (5092)S = soldered connectorwww = length in cmX = D for DIN 7-16 type connector
N for N type connectorY = M for male or F for femaleZ = L for right angle connector
Marking
• Manufacturer EUPEN• Week & Year of Production• Product Ref.: for ex.: EC4-HF-S-200-DMDM• Torque• Product Nr. EUPEN• Serial Number
SOLDERED JUMPER CABLES
Kabelwerk Eupen AG 31
Jumper cables
Technical data
Cable type EC4-50-HF (5092) EC4-50 (5128)1/2”-HIFLEX 1/2”
Electrical• Nominal impedance [Ω] 50 ±1• Frequency range [MHz] 10 - 2700• PIM ratio (2 x 20 W carrier) [dBc] ≤ -155 (Typical -163)• Attenuation per m at 20 °C [dB] - without connectors*
960 MHz 0.106 0.0711880 MHz 0.151 0.1032200 MHz 0.170 0.1132600 MHz 0.187 0.123
• RF Voltage rating (Peak) [V] 1130 1600• Relative propagation velocity [%] 82 88
Mechanical• Minimum bending radius [mm]
- single 30 70- repeated 30 125
• Connector torque (nominal) [Nm]- DIN 7-16 connector 28 28- N type connector 12 12
Environmental• Temperature range [°C]
- installation -40 to +60- operating -55 to +85
• Protection against water ingress Water tightness acc. to IP 68 (0.5 bar / 24 h)- Longitudinal water tightness Two O-rings in the DIN 7-16 connector head
• General environmental Corrosion and UV resistant• RoHS compliance (EU Directive 2002/95/EC) YES
Maximum power rating [W]Connector 1 Connector 2 Reference 800 - 1000 MHz 1700 - 2700 MHz 800 - 1000 MHz 1700 - 2700 MHz
7-16 7-16 ...-DyzDyz 650 350 800 4507-16 N ...-DyzNyz 600 300 600 300N N ...-NyzNyz 600 300 600 300
Return loss [dB] (VSWR)**Connector 1 Connector 2 Reference 800 - 1000 MHz 1700 - 2700 MHz 800 - 1000 MHz 1700 - 2700 MHz
7-16 7-16 ...-DyDy > 32 (< 1.05) > 29 (< 1.075) > 32 (< 1.05) > 29 (< 1.075)...-DyDML > 30 (< 1.065) > 28 (< 1.08) - -...-DMLDML > 28 (< 1.08) > 26 (< 1.10) - -
7-16 N ...-DyNy > 32 (< 1.05) > 29 (< 1.075) > 32 (< 1.05) > 29 (< 1.075)...-DyNML > 30 (< 1.065) > 28 (< 1.08) - -...-DMLNy > 30 (< 1.065) > 28 (< 1.08) - -...-DMLNML > 28 (< 1.08) > 26 (< 1,10) - -
N N ...-NyNy > 30 (< 1.065) > 27 (< 1.09) > 30 (< 1.065) > 27 (< 1.09)...-NyNML > 29 (< 1.07) > 27 (< 1.09) - -...-NMLNML > 28 (< 1.08) > 26 (< 1.10) - -
* Typical values without connectors, the typical connector attenuation (2 connectors) is less than 0.02 [dB]** These values are given for a length of the jumper up to 10 meters.
Eupen offers a wide range of inside-series and inter-series 7-16 DIN and N type adapters designed inpremium and precision models.
Features
• Low reflection coefficient up to 2.7 GHz• Low PIM (-163dBc)• high contact force realized with inner contactsmade in a high-strength copper alloy
• Silver plated• Watertight (IP67/IP68)• Corrosion resistant
Premium adapters are characterised by a minimumReturn loss of -34 dB up to 2.7 GHz.
For applications where high electrical performancesand very low return loss are requested, and wherehigh precision measurement equipment is requested- such as field test application in the cellular commu-nication - we offer high precision adaptors featuringlowest return loss with guaranteed minimum -40 dBup to 2.7 GHz.
Description Reference
N male to 7-16 male AD50NM716MN female to 7-16 male AD50NF716MN male to 7-16 female AD50NM716FN female to 7-16 female AD50NF716FN male to N female AD50NMFN male to N male AD50NMMN female to N female AD50NFF7-16 male to 7-16 female AD50716MF7-16 female to 7-16 female AD50716FF7-16 male to 7-16 male AD50716MM
Description Reference
N male to 7-16 male PRAD50NM716MN female to 7-16 male PRAD50NF716MN male to 7-16 female PRAD50NM716FN female to 7-16 female PRAD50NF716F7-16 female to 7-16 female PRAD50716FF7-16 male to 7-16 male PRAD50716MM
A. premium adapters
B. precision adapters
32 Kabelwerk Eupen AG
ACCESSORIES FOR
CABLES
1. adapters
2. preset torque wrench selection guide
Important: Hold connector body fixed while turning back nut with torque wrench.
* only available on request
Connector Size Head thickness Torque value Reference
mm (in) mm Nm (ft-lb)
1/2” 19 (3/4”) 7 20 (15) TQ-34-F15
1/2”-Hiflex 19 (3/4”) 7 27 (20) TQ-34-F20
7/8” & 7/8”-Hiflex 30 (1-3/16”) 12 30 (22) TQ-30MM-F22
1-1/4” & 1-1/4”-Hiflex 43 (1-11/16”) 13 40 (29) TQ-11116-F29
1-5/8” 58 (2-1/4”) 13 50 (37) TQ-214-F37
2-1/4” 67 (2-5/8”) 13 50 (37) TQ-258-F37*
Connector Size Head thickness Torque value Reference
mm (in) mm Nm (ft-lb)
7-16 DIN coupling nut 32 (1-1/4”) 13 25 (18) TQ-114-F18-M
Kabelwerk Eupen AG 33
Accessories for cables
A. blue wrench handles for connector back nuts
B. red wrench handles for connector interfaces
The torque wrenches emit an audible ”click” when the specified torque is reached. Proper tightening ensures water-tightness andprevents loosening from vibration.
GROUNDING CLAMPS
Reference GCS14 GCS38 GCS12X GCS12PAR GCS78PAR GCS114PAR GCS158PAR GCS214PAR
Cable size 1/4” 3/8” 1/2” Hiflex 1/2” 7/8”A & 7/8” Hiflex 1-1/4”A & 1-1/4” Hiflex 1-5/8”A 2-1/4”Outlet 90° 90° 90° parallel parallel parallel parallel parallelCable cut (mm) 24 20 24 25 21 26 30 30
For further details please refer to technical specifications.
34 Kabelwerk Eupen AG
3. grounding clamps
The optimal grounding of the transmissionline antenna to base station is a very weakpoint. In order to guarantee the best ground-ing we recommend the use of the EUPENgrounding clamps in order to ground thecoaxial outer conductor to the antenna toweror ground wire. The main features of theEupen grounding clamps are:
• Ultra quick and easy installation • No loose parts • Lightning resistant to 100kA light-ning current (wave type 10/350 µs)
• Very low contact resistance< 1mOhm
• Waterproof according IP67 / IP68 without additional tape or sealant
• Corrosion resistant• Reusable
A. grounding clamps ”GCS”
B. connector grounding kit “CGC” 12-158
Features
• Fast, easy and reliable installation• Low contact resistance• Corrosion resistant stainless steel material• Reusable• Only one model for all the connector sizes from 1/2” to 1-5/8”
Description
• Stainless steel connector grounding clamp• 60 cm lead with attachment lug and stainless steel M6Allen screw, washer and nut.
GCS grounding clampwith 90° outlet
GCS grounding clampwith parallel outlet
Kabelwerk Eupen AG 35
Accessories for cables
A. eucatecTM rf cable clamps with lock nut
Please contact us for a comprehensive list of the available versions.
Features
• High durability given by non-corrosive metal components ofV2A stainless steel and calibrated saddles from ultravioletand aging resistant polyamide
• Mountable at ”C”-profile rails usual in radio systems as wellas flat sections to a maximum of 25 mm thickness andtubes up to a diameter of 25 mm (according to clamp type)
• Easy handling; the cable clamps (single type) consist ofmerely two elements
• Inlet design with crotchet on both sides to retain the saddlesin the clamp while fixing the cable
• Protection of the cable against a possible harm through thetensioning screw is ensured since the tensioning screw iscombined firmly with the polyamide shell
• Extra-secure hold is achieved by the use of a look nut
• All EUCATEC Cable Clamps are available in single, doubleor triple version
• Also available without look nut
40 or 50 mm
R25
8 mm 9 mm
R11
ECC-U-...-LN
ECC-A-...-LN
ECC-C-...-LN
ECC-F-...-LN
ECC-U11-...-LN
Suitable profile types
• Standard C-Profile• Flat sections• Pipes• Right angle
4. fixing clamps
ECC-C-2x78-LN
36 Kabelwerk Eupen AG
OPTION: Angle Adapter for snap-in or clip hangers
Material : Stainless steel
EU-SH78L
EU-CH78NH
Other specific clamps are available on request
snap-in hangers clip hangers
Reference 1/2” 7/8” 1-1/4” 1-5/8” 2-1/4”
Snap-In EU-SH12L EU-SH78L EU-SH114L EU-SH158L EU-SH214LClip Hangers EU-CH12NH EU-CH78NH EU-CH114NH EU-CH158NH –
• For mainting on flat plate or angle • No additional hardware required• Orientable
Reference 1/2” 7/8” 1-1/4” 1-5/8”
Spring Clamp EU-ES9016 EU-ES9028 EU-ES9040 EU-ES9040
B. stainless steel clamp system
Description Reference
Angle Adapter EU-AA-SL
C. orientable stainless steel spring clamp
Kabelwerk Eupen AG 37
Accessories for cables
SIL-744
Reference 3/8” 1/2” 7/8” 1-1/4” 1-5/8” 2-1/4”
with 90 ml tube 26...30 20...25 13...15 7...9 4...5 3...4with 310 ml tube 90...103 69...86 44...51 24...31 13...17 10...13
With one tube the following quantities of connectors can be sealed:
We offer two types of hoisting grips: the lace-up one and thepre-laced one.Please refer to the table below.Hoisting grips are used to raise the cable up the tower. Theycan be tied off as a permanent support. Use one hoisting gripfor every 60 m cable length.
The hoisting grips are manufactured from high-grade tin coat-ed bronze to provide highest corrosion resistance.
5. hoisting grips
HOISTING GRIPS
Reference 1/2” 7/8” 1-1/4” 1-5/8”
Lace-up type HG-12 HG-78 HG-114 HG-158Pre-laced type HG-12-L HG-78-L HG-114-L HG-158-L
6. sealant sil-744 for connectors with sealant injection
In outdoor installations the Connector/Cable interface is verysensitive to water ingress.The Sealant injection waterproofing method creates a quick,secure seal between the back nut and jacket / outer conduc-tor.
The SIL-744 is recommended to be used with all EUPENconnectors where sealant injection is required.The SIL-744 is supplied either in a box with a 90 ml tube ofsealant including connector adapter and key or in a tube con-taining 310 ml.
38 Kabelwerk Eupen AG
ES-12-114
7. eucaseal
The Eucaseal is an additional and optional gel closure sealingsystem that provides a reliable sealing of coaxial connectorsused at the transition between:• jumper and antennas or the electric devices like TMA’S ....• jumper and feeder cables exposed to the outside environment
Features
• Reliable protection over a wide temperature range: -30 °C to 60 °C
• Wraparound and no disconnection of the connector• Quick and easy to install• Easily removable and re-usable• Gel material provides an effective barrier against ingress ofwater and other contaminants - IP 68 acc. EN 60529
• No tape, no mastics or tools required for installation andremoval
• UV resistant• Tested under extremely severe conditions, vibrations (acc. IEC 60068-2-6 Test Fc) and temperature cycles (acc. IEC 60068-2-14 Test Nb)
• Protection against excessive bending of the cable.
Benefit
The housing contains an innovative gel material and providesan efficient moisture block. The ease of installation and thelong-term protection makes it a reliable and cost effictive solu-tion.
ES-12-78
ES-12-114
Kabelwerk Eupen AG 39
Accessories for cables
EUCASEAL
Application 1/2” jumper to 1/2” jumper to 1/2” jumper to 1/2” jumper toantenna or box 7/8” feeder 1-1/4” feeder 1-5/8” feeder
Reference ES-12-BOX ES-12-78 ES-12-114 ES-12-158
Cable type 1/2” & 1/2” Hiflex 1/2” & 1/2” Hiflex 1/2” & 1/2” Hiflex 1/2” & 1/2” Hiflexto 7/8”A or 7/8” Hiflex to 1-1/4”A or 1-1/4” Hiflex to 1-5/8”A
Connector type only DIN 7-16 N or 7-16 N or 7-16 N or 7-16- max. length 60 mm
- max. body diameter 26,6 mm- nominal distance betweenpanel connectors 45 mm
Available in black and greyFor further details please refer to technical specifications.
ES-12-BOX
ES-12-BOX
Features
• Quick and easy to install• Basic range from 800 to 2500 MHz• Arrester method: 1/4 Wave
Technical Data **
• Impedance: 50 Ohm • Insertion loss: < 0.1 dB• Return Loss (VSWR): < 1.15• Surge current handling capability at least 20 kA (8/20 µS)• Max. power: 300W ***
Reference
for ex.: EU-LA-QW-800-2500-DM-DF
* Bulkhead version available on request** For further details please refer to technical specifications*** 150 W for version with gas-tube
40 Kabelwerk Eupen AG
Our lightning arresters offer an additional protectionfor the BTS against lightning damages and can beused in wideband applications from 800 to 2500MHz.
In addition to the 1/4 wave lightning arrester, anhybrid version with a replaceable gas capsule isavailable, which permits the transmission of DC-vol-tage.
8. lightning arresters
Quarter wave lightning arrester*
ref: EU-LA-QW-800-2500-DMDF
”Hybrid” gas-tube +1/4 wave lightning arrester
ref: EU-LA-QWG230-800-2500-DM-DFP
Kabelwerk Eupen AG 41
Accessories for cables
If additional weatherproofing is required, it can be achieved with appropriate adhesive tapes wrapped around the cable/connectorinterface. EUPEN supplies a weatherproofing tape kit for additional protection of connector, cable and jumper junctions.
9. weatherproofing tape kit
TECHNICAL DATA
Cable/Connector 1/4” & 3/8” 1/2” & 1/2”X 7/8” 1-1/4” 1-5/8”
Single connector 10 9 7 5 3Splice 6 5 4 3 2
The following table indicates the quantity of connectors or
splices which can be sealed with 1 kit:
PRODUCT OVERVIEW
Product Reference Contents
Weatherproofing tape kit 1 roll of self-fusing butyl tape (65 mm x 2 m)1 roll of black PVC tape (25 mm x 20 m)
Butyl mastic tape
• Material self-fusing butyl (lead free)• Color black• Length (m) 2• Width (mm) 65• Thickness (mm) 2.5
Adhesive all-weather PVC-tape• Backing PVC (lead free)• Color black• Length (m) 20• Width 25• Thickness (mm) 0.2• Tensile strength (N/cm) ≥ 20• Elongation (%) ≥ 200• Temperature range (°C) -40 to +105• Resistance to flame propagation self-extinguishing• Dielectric strength (kV/mm) ≥ 40
Features
• Universal weatherproofing• Special weather resistant PVC-Tape• Suitable for difficult weather conditions
Aw
W
d D
42 Kabelwerk Eupen AG
CABLE PACKING ANDHANDLING INFORMATION
The coaxial cable will be supplied on wooden drumsmade of planed wooden boards or plywood. In orderto protect the cable during transportation and stor-age, the drums will be battened with wooden boardsnailed on the flanges.The drums are provided with a label containing cableinformation as cable type, cable length and produc-tion batch (see label on right). The drums can beimpregnated on request.
[1] These combinations cable/length/drum are examples of the most common cases. Others are possible under request.[2] battened + 5 cm[3] Depending on the humidity of the wood, drum weights can vary greatly![4] Standard PE jacket
The standard drum sizes used for the different cabletypes are shown in the table below.
Most used drums per cable type[1]:
Cable type Drum type Usual length Outer diam.[2] Drum diam. D d W w A d
(m) (cm) (cm)
EC1-50 (5062) 1/4” HE 07 up to 650 70 40 EC1-50 (5062) 1/4” HE 08 HF from 650 to 1350 80 40 EC1-50-HF (5042) 1/4” Hiflex HE 07 up to 1200 70 40 EC1-50-HF (5042) 1/4” Hiflex HE 08 HF from 1200 to 2150 80 40 EC2-50 (5088) 3/8” HE 07 up to 450 70 40 EC2-50 (5088) 3/8” HE 08 HF from 450 to 900 80 40 EC4-50 (5128) 1/2” HE 07 up to 250 70 40 EC4-50 (5128) 1/2” HE 08 HF from 250 to 500 80 40 EC4-50 (5128) 1/2” HE 12 from 500 to 1500 120 40 EC4-50-HF (5092) 1/2” Hiflex HE 07 up to 330 70 40 EC4-50-HF (5092) 1/2” Hiflex HE 08 HF from 330 to 750 80 40 EC4.5-50 (5168) 5/8” HE 12 up to 800 120 40 EC4.5-50 (5168) 5/8” HE 13 from 800 to 1300 130 47 EC5-50-A (5228A) 7/8”A HE 12 up to 500 120 40 EC5-50-A (5228A) 7/8”A HE 13 from 500 to 900 130 47 EC5-50-HF (5228X) 7/8” Hiflex HE 12 up to 500 120 40 EC5-50-HF (5228X) 7/8” Hiflex HE 13 from 500 to 900 130 47 EC6-50-A (5328A) 1-1/4” A HF 17S up to 500 170 90 EC6-50-A (5328A) 1-1/4” A HF 17B from 500 to 700 170 90 EC6-50-A (5328A) 1-1/4” A HF 18 from 700 to 900 180 90 EC6-50-A (5328A) 1-1/4” A HF 20 from 900 to 1300 200 90 EC6-50-HF (5328X) 1-1/4” Hiflex HF 17S up to 500 170 90 EC6-50-HF (5328X) 1-1/4” Hiflex HF 17B from 500 to 700 170 90 EC6-50-HF (5328X) 1-1/4” Hiflex HF 18 from 700 to 900 180 90 EC6-50-HF (5328X) 1-1/4” Hiflex HF 20 from 900 to 1300 200 90 EC7-50-A (5438A) 1-5/8”A HF 17S up to 270 170 90 EC7-50-A (5438A) 1-5/8”A HF 18 from 270 to 500 180 90 EC7-50-A (5438A) 1-5/8”A HF 20 from 500 to 850 200 90 EC12-50 (5528) 2-1/4” HF 17B up to 250 170 90 EC12-50 (5528) 2-1/4” HF 20 from 250 to 550 200 90
Kabelwerk Eupen AG 43
Packing information
Drum label
Outer width Inner width Shaft hole Freight volume Approx. drum weight Approx.W w A drum/battened drum drum/battened drum[3] cable weight[4]
(cm) (cm) (cm) (m3) (kg) (kg/km)
42 40 6.5 0.20 / - 7 / - 111 53 50 6.5 0.34 / 0.38 16 / 35 111
42 40 6.5 0.20 / - 7 / - 83 53 50 6.5 0.34 / 0.38 16 / 35 83
42 40 6.5 0.20 / - 7 / - 146 53 50 6.5 0.34 / 0.38 16 / 35 146 42 40 6.5 0.20 / - 7 / - 231 53 50 6.5 0.34 / 0.38 16 / 35 231 53 49 8.0 0.77 / 0.82 25 / 60 231
42 40 6.5 0.20 / - 7 / - 193 53 50 6.5 0.34 / 0.38 16 / 35 193
53 49 8.0 0.77 / 0.82 25 / 60 345 76 72 8.0 1.28 / 1.36 40 / 90 345 53 49 8.0 0.77 / 0.82 25 / 60 436 76 72 8.0 1.28 / 1.36 40 / 90 436 53 49 8.0 0.77 / 0.82 25 / 60 475 76 72 8.0 1.28 / 1.36 40 / 90 475 74 64 9.0 2.14 / 2.24 150 / 215 803 102 92 9.0 2.95 / 3.12 175 / 250 803 102 92 9.0 3.30 / 3.49 200 / 300 803 116 104 9.0 4.64 / 4.87 280 / 415 803 74 64 9.0 2.14 / 2.24 150 / 215 754 102 92 9.0 2.95 / 3.12 175 / 250 754 102 92 9.0 3.30 / 3.49 200 / 300 754 116 104 9.0 4.64 / 4.87 280 / 415 754 74 64 9.0 2.14 / 2.24 150 / 215 1019 102 92 9.0 3.30 / 3.49 200 / 300 1019 116 104 9.0 4.64 / 4.87 280 / 415 1019 102 92 9.0 2.95 / 3.12 175 / 250 1838 116 104 9.0 4.64 / 4.87 280 / 415 1838
01/2012 - 2000 pc (K)
Malmedyer Str. 9 - 4700 EUPEN - BELGIUM
Tel.: +32(0)87.59.70.00 Fax: +32(0)87.59.71.00http://www.eupen.com e-mail:[email protected] ISO Certified Company