5 PG PUMP - Yahoo6 R800019 315061 Prefilter Screen, PG 2700 6 R800020 315078 Prefilter Screen,...

1
Lifegard Aquatics 16301 Carmenita Road Cerritos, CA 90703 Tel (562)404-4129 Fax (562)404-4159 www.lifegardaquatics.com Email: [email protected] 1 6 3 4 2 Using a pair of needle-nose pliers, very gently grip the shaft with the tip of the pliers while also locking in one of the tabs at the same time. Gently turn the shaft counter-clockwise while pushing on the tab to unlock the impeller assembly. Pull the assembly straight out to remove from motor housing. See fig – c, d and e. Use only minimal force while doing this to avoid damaging the tabs on the pump or the impeller assembly. Visually inspect the impeller assembly for any damage. The impeller assembly for PG Pumps is one assembly as shown in Figure - 4 Tab Tab Shaft Cleaning the Impeller and Volute chamber: To clean the volute chamber and impeller remove the volute by rotating it counter clockwise. This will expose the pump impeller. To clean the volute chamber and impeller use a garden hose to spray out any debris. To clean or replace the impeller assembly, first remove the front housing by rotating it counter clockwise (See Figure – a and b). With the impeller exposed locate the three tabs. Cleaning or Replacing the Impeller: Figure - a Figure - b O-ring Ceramic Shaft Metallic Rotor Installing Impeller Assembly and Front Housing: Before reinstalling the impeller assembly it is recommended to use Lifegard Silicon lubricant on the ceramic shaft, metallic rotor of the impeller assembly and the o-ring on the pump body. After this is complete, reinstall all the components back into the pump by sliding the impeller assembly back into the motor housing. Using a pair of needle-nose pliers,very gently grip the shaft and one of the tabs and at the same time and turn clockwise while gently pushing on the tab to lock the impeller assembly. When you hear a click sound it means the impeller is locked. Use only minimal force while doing this to avoid damaging the tabs on the pump or the impeller assembly. Figure - c Figure - e Figure - f Figure - d Reinstalling the Front Housing by sliding it over the impeller chamber and rotating it clockwise until it locks at the desired position. SELECT OUTLET POSITION: Place the pump flat on its base.To get Position2 , Position 3, Position 4 as shown below the body of the pump needs to rotate withen the handle/stand and Lock into Notches A, B or C respectively located in the base of the handle/stand. To get Position 1 rotate the pump into Notch A while the volute is removed and manually rotated Counter Clockwise into the desired positon.To get Position 5 rotate the pump into Notch C while the volute is removed and manually rotated clockwise into the desired positon. Position 1 Position 2 Position 3 Position 4 Position 5 Label Notch - A, Notch - B, Notch - C Notch-A A B C Notch-B Notch-C Lock Pump Maintenance: This pump design features a water lubricated ceramic bearing and shaft for long lasting service. However, the rotor assembly is susceptible to failure if sand or extra fine grit is being pumped. · CAUTION: Always disconnect the pump when performing any maintenance or handling. · Check the circuit breaker and try another (GFCI) outlet to ensure the pump is getting electrical power. · Check the pump discharge, impeller and tubing for obstructions. · Check the inlet screen to ensure it is not clogged · After removing the volute, rotate the impeller by hand to insure that it can spin freely. LIMITED WARRANTY The Lifegard PG pumps are warranted to the user against defective material and workmanship under normal use, for a period of 1 year from the date of purchase by the original purchaser. Replacement liability in all events is limited to the replacing or repairing at Lifegard’s sole discretion of any part or parts, which are defective in material or workmanship. Proof of purchase is required on all claims in the form of invoice copy, sales ticket, etc. APPLICATION: Warranty covers only properly installed and maintained units. Warranty is limited to applications pumping fresh water at temperatures of 32°-86°F (0°- 30°C), with a pH range of 5 to 9. Lifegard Aquatics must approve other liquid applications and extreme temperature uses in advance in writing. INSTALLATION and/or REMOVAL CHARGES: Warranty does not cover any costs associated with the installation or removal of products subject to warranty claims. DISPOSITION: Lifegard will make a good-faith effort for prompt disposition regarding any item in warranty, which proves to be defective. If productswere damaged in transit, please file a claim with the carrier. 5 Parts Breakdown UPC Item Part No. 788379+ DESCRIPTION 2 R800000 314927 “O” Ring, PG 1600 PG 5300 2 R800001 314934 “O” Ring, PGPG 2700 2 2 R800002 R800003 314941 314958 “O” Ring, PGPG 4500 & “O” Ring, PG 6600 3 R800009 314965 Impeller Assembly, PG 1600 3 R800010 314972 Impeller Assembly, PG 2700 3 R800011 314989 Impeller Assembly, PG 4500 3 R800012 314996 Impeller Assembly, PG 5300 3 R800013 315009 Impeller Assembly, PG 6600 4 R800014 315016 Front Housing, PG 1600 4 R800015 315023 Front Housing, PG 2700 4 R800016 315030 Front Housing, PG 4500 & PG 5300 4 R800017 315047 Front Housing, PG 6600 UPC Item Part No. 788379+ DESCRIPTION 6 R800018 315054 Prefilter Screen, PG 1600 6 R800019 315061 Prefilter Screen, PG 2700 6 R800020 315078 Prefilter Screen, PG4500 & PG 5300 6 R800021 315085 Prefilter Screen, PG6600 5 R800022 315092 Flexible Tube Fitting, PG 2700, 3 /4" or 1" ID 5 R800023 315108 Flexible Tube Fitting, PG 1600, 1" or 1 1 /4" ID 5 R800024 315115 Flexible Tube Fitting, PG 4500, & PG 5300, 1 1 /4" or 1 1 /2" ID 5 R8000 0 25 315122 Flexible Tube Fitting, PG 6000, 1 1 /2" or 2" ID 7 R800 26 315139 Suction Cups, PG Pumps (set of 4) PG PUMP PARTS INSTRUCTION MANUAL PONDS FOUNTAINS WATERFALLS PG PUMP Lifegard PG Pump Instructions: High performance energy-efficient pumps designed for use in Ponds, Fountains, Waterfalls, Hydroponic Systems, Irrigation Systems and Water Features. For use in either wet or dry installations and features Wet Rotor/Wet Bearing Technology for cooler running. Pre-filter screen handles large particles for less maintenance. Multiple size Insert Fitting and Suction Cups included. Designed for Fresh water use only. PG 1600 Watts: 90 Amps: 0.8 Voltage: 120V 60Hz Horse Power: 0.12HP Inlet/Outlet: 1” Flexible Tube Size: 3/4” or 1” ID FLOW RATE (gph) 1585 1506 1189 978 740 542 370 251 132 0 HEAD (ft) 0.0 0.7 3.3 4.9 6.6 8.2 9.8 11.5 13.1 15.7 FLOW RATE (gph) 2642 2325 1982 1638 1295 978 700 462 264 0 HEAD (ft) 0.0 1.6 3.3 4.9 6.6 8.2 9.8 11.5 13.1 15.7 PG 2700 Watts: 120 Amps: 1.1 Voltage: 120V 60Hz Horse Power: 0.16HP Inlet/Outlet: 11/4Flexible Tube Size: 1” or 1 1/4” ID PG 4500 Watts: 220 Amps: 2.0 Voltage: 120V 60Hz Horse Power: 0.30HP Inlet/Outlet: 11/2Flexible Tube Size: 1 1/4” or 1 1/2” ID FLOW RATE (gph) 4491 4227 3831 3329 2814 2259 1783 1347 951 608 357 0 HEAD (ft) 0.0 1.6 3.3 4.9 6.6 8.2 9.8 11.5 13.1 14.8 16.4 19.4 PG 5300 Watts: 310 Amps: 2.7 Voltage: 120V 60Hz Horse Power: 0.42HP Inlet/Outlet: 11/2Flexible Tube Size: 1 1/4” or 1 1/2” ID FLOW RATE (gph) 5284 5020 4756 4412 4042 3620 3197 2721 2219 1717 1189 793 476 238 0 HEAD (ft) 0.0 1.6 3.3 4.9 6.6 8.2 9.8 11.5 13.1 14.8 16.4 18.0 19.7 21.3 24.0 PG 6600 Watts: 325 Amps: 2.90 Voltage: 120V 60Hz Horse Power: 0.45HP Inlet/Outlet: 2” Flexible Tube Size: 11/2” or 2” ID FLOW RATE (gph) 6605 5548 4808 4201 3620 3065 2523 2005 1480 991 594 264 0 HEAD (ft) 0.0 3.0 4.9 6.6 8.2 9.8 11.5 13.1 14.8 16.4 18.2 20.3 22.6 ALL Pro Series 0 300 600 900 1200 1500 1800 2100 2400 2700 18 16 14 12 10 8 6 4 2 0 FLOW RATE (gph) HEAD (ft) PG 1600 PG 2700 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 24 20 18 16 14 12 10 8 6 4 2 0 FLOW RATE (gph) HEAD (ft) PG 6600 PG 5300 PG 4500 Warranty period starts from date of purchase and must be validated with copy of original purchase receipt. Warranty requests by phone will not be honored. Warranty items returned without copy of original purchase receipt will not be honored. Products purchased from eBay, craigslist, etc cannot be honored for warranty unless returned through original purchaser . e s a h c r u p f o f o o r p h t i w All items must first be returned to Lifegard Aquatics for inspection, evaluation, and processing to determine if product qualifies for warranty replacement or repair. No warranty (repair, replacement, or credit) will be issued prior to inspection of product Please contact us first for warranty assistance. Many times the product can be repaired without the cost and. time involved in sending it back to us. If absolutely necessary, return product freight prepaid to the following address for warranty evaluation and processing. Lifegard Aquatics Cerritos, CA 90703 m o c . s c i t a u q a d r a g e f i l @ o f n i : l i a m E 9 5 1 4 - 4 0 4 ) 2 6 5 ( x a F 3 year warranty from date of purchase on Quiet One Pump Motors Only. 60 day warranty from date of purchase on Shafts and Impellers for All Types of Pumps. 60 day warranty from date of purchase on all Ultraviolet Bulbs. 60 day warranty from date of purchase on all Test Strips. 1 year warranty from date of purchase on All Other Products including PG Pumps, LED Lights, Heaters. . Pump Maintenance: This pump design features a water lubricated ceramic bearing and shaft for long lasting service. However, the rotor assembly is susceptible to failure if sand or extra fine grit is being pumped. forming any maintenance or handling. · CAUTION: Always disconnect the pump when per · Check the circuit breaker and try another (GFCI) outlet to ensure the pump is getting electrical power. · Check the pump discharge, impeller and tubing for obstructions. · Check the inlet screen to ensure it is not clogged · After removing the volute, rotate the impeller by hand to insure that it can spin freely. 16301 Carmenita Road Tel (562)404-4129 5 DISCLAIMER: Lifegard Aquatics will not be liable for any labor cost of removing or replacing component parts. This shall be the responsibility of the original purchaser, as will be the shipping charge to Lifegard Aquatics facility. Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, should not be relied upon by the user, and are not part of the contract for sale. Seller's and manufacturer's only obligation and buyer's and user's only remedy, shall be for the manufacturer to either replace and/ or repair at the manufacturer's sole discretion the Lifegard product as described above. Neither seller nor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Damage or failure of any part of a unit covered by this warranty, which results from causes directly, or indirectly connected with the installation, operation, environment, use or willful abuse, including without limitations, improper repackaging and damage incurred in shipping is not covered by this warranty. Unless state law provides otherwise, the manufacturer will only be responsible for repair or replacement of any of its products or parts that are found to be defective, and will not bear any cost of any incidental or consequential damages arising out of the occurrence of such defect. Before using, the buyer and user shall determine the suitability of the product for the intended use, and assumes all risk and liability whatsoever in connection herewith. The warranty and remedy described in this limited warranty is an EXCLUSIVE warranty and remedy. IN LIEU of any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED, including but not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This Warranty gives buyer and user specific legal rights, and buyer and user may also have other rights that vary from state to state. Some states donot allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Jolie Products, Inc

Transcript of 5 PG PUMP - Yahoo6 R800019 315061 Prefilter Screen, PG 2700 6 R800020 315078 Prefilter Screen,...

Page 1: 5 PG PUMP - Yahoo6 R800019 315061 Prefilter Screen, PG 2700 6 R800020 315078 Prefilter Screen, PG4500 & PG 5300 6 R800021 315085 Prefilter Screen, PG6600 5 R800022 315092 Flexible

Lifegard Aquatics 16301 Carmenita RoadCerritos, CA 90703 Tel (562)404-4129 Fax (562)404-4159

www.lifegardaquatics.com Email: [email protected]

16

3 42

Using a pair of needle-nose pliers, very gently grip the shaft with the tip of the pliers while also locking in one of the tabs at the same time. Gently turn the shaft counter-clockwisewhile pushing on the tab to unlock the impeller assembly. Pull the assembly straight out to remove from motor housing. See fig – c, d and e. Use only minimal force whiledoing this to avoid damaging the tabs on the pump or the impeller assembly. Visuallyinspect the impeller assembly for any damage. The impeller assembly for PG Pumpsis one assembly as shown in Figure - 4

Tab

Tab

Shaft

Cleaning the Impeller and Volute chamber:

To clean the volute chamber and impeller remove the volute by rotating it counterclockwise. This will expose the pump impeller. To clean the volute chamber and impelleruse a garden hose to spray out any debris.

To clean or replace the impeller assembly, first remove the front housing by rotating it counter clockwise (See Figure – a and b). With the impeller exposed locate the three tabs.

Cleaning or Replacing the Impeller:

Figure - a Figure - b

O-ring Ceramic Shaft Metallic Rotor

Installing Impeller Assembly and Front Housing:

Before reinstalling the impeller assembly it is recommended to use Lifegard Siliconlubricant on the ceramic shaft, metallic rotor of the impeller assembly and the o-ringon the pump body. After this is complete, reinstall all the components back into the pump by sliding the impeller assembly back into the motor housing.

Using a pair of needle-nose pliers,very gently grip the shaft and one of the tabs andat the same time and turn clockwise while gently pushing on the tab to lock the impellerassembly. When you hear a click sound it means the impeller is locked. Use only minimal force while doing this to avoid damaging the tabs on the pump or the impellerassembly.

Figure - c Figure - e

Figure - f

Figure - d

Reinstalling the Front Housing by sliding it over the impeller chamber and rotating itclockwise until it locks at the desired position.

SELECT OUTLET POSITION:Place the pump flat on its base.To get Position2 , Position 3, Position 4 as shown belowthe body of the pump needs to rotate withen the handle/stand and Lock into NotchesA, B or C respectively located in the base of the handle/stand. To get Position 1 rotatethe pump into Notch A while the volute is removed and manually rotated CounterClockwise into the desired positon.To get Position 5 rotate the pump into Notch C while the volute is removed and manually rotated clockwise into the desired positon.

Position 1 Position 2 Position 3 Position 4 Position 5

Label Notch - A, Notch - B, Notch - C

Notch-A

A B C

Notch-BNotch-C

Lock

Pump Maintenance:This pump design features a water lubricated ceramic bearing and shaft for long lasting service. However, the rotor assembly is susceptible to failure if sand or extra fine grit is being pumped.· CAUTION: Always disconnect the pump when performing any maintenance or handling.· Check the circuit breaker and try another (GFCI) outlet to ensure the pump is getting electricalpower.

· Check the pump discharge, impeller and tubing for obstructions.· Check the inlet screen to ensure it is not clogged· After removing the volute, rotate the impeller by hand to insure that it can spin freely.

LIMITED WARRANTY The Lifegard PG pumps are warranted to the user against defective material and workmanship under normal use, for a period of 1 year from the date of purchase by the original purchaser. Replacement liability in all events is limited to the replacing or repairing at Lifegard’s sole discretion of any part or parts, which are defective in material or workmanship. Proof of purchase is required on all claims in the form of invoice copy, sales ticket, etc. APPLICATION: Warranty covers only properly installed and maintained units. Warranty is limited to applications pumping fresh water at temperatures of 32°-86°F (0°- 30°C), with a pH range of 5 to9. Lifegard Aquatics must approve other liquid applications and extreme temperature uses in advance in writing. INSTALLATION and/or REMOVAL CHARGES: Warranty does not cover any costs associated with the installation or removal of products subject to warranty claims. DISPOSITION: Lifegard will make a good-faith effort for prompt disposition regarding any item in warranty, which proves to be defective. If productswere damaged in transit, please file a claim with the carrier.

5

Parts Breakdown

UPCItem Part No. 788379+ DESCRIPTION2 R800000 314927 “O” Ring, PG 1600

PG 5300

2 R800001 314934 “O” Ring, PGPG 27002

2

R800002

R800003

314941

314958

“O” Ring, PGPG 4500 &

“O” Ring, PG 66003 R800009 314965 Impeller Assembly, PG 16003 R800010 314972 Impeller Assembly, PG 27003 R800011 314989 Impeller Assembly, PG 45003 R800012 314996 Impeller Assembly, PG 53003 R800013 315009 Impeller Assembly, PG 66004 R800014 315016 Front Housing, PG 16004 R800015 315023 Front Housing, PG 27004 R800016 315030 Front Housing, PG 4500

& PG 53004 R800017 315047 Front Housing, PG 6600

UPCItem Part No. 788379+ DESCRIPTION6 R800018 315054 Prefilter Screen, PG 16006 R800019 315061 Prefilter Screen, PG 27006 R800020 315078 Prefilter Screen, PG4500

& PG 53006 R800021 315085 Prefilter Screen, PG66005 R800022 315092 Flexible Tube Fitting, PG 2700,

3/4" or 1" ID5 R800023 315108 Flexible Tube Fitting, PG 1600,

1" or 11/4" ID5 R800024 315115 Flexible Tube Fitting, PG 4500,

& PG 5300, 11/4" or 11/2" ID5 R8000

0

25 315122 Flexible Tube Fitting, PG 6000, 11/2" or 2" ID

7 R800 26 315139 Suction Cups, PG Pumps (set of 4)

PG PUM P PARTS

INSTRUCTION MANUAL PONDS FOUNTAINS WATERFALLS

PG PUMP

Lifegard PG Pump Instructions: Highperformance energy-efficient pumps designed for use in Ponds, Fountains, Waterfalls, Hydroponic Systems, Irrigation Systems and Water Features. For use ineither wet or dry installations and features Wet Rotor/Wet Bearing Technology for coolerrunning. Pre-filter screen handles largeparticles for less maintenance. Multiple sizeInsert Fitting and Suction Cups included.Designed for Fresh water use only.

PG 1600Watts: 90 Amps: 0.8Voltage: 120V 60HzHorse Power: 0.12HPInlet/Outlet: 1”Flexible Tube Size: 3/4” or 1” ID

FLOW RATE(gph)

158515061189978740542370251132

0

HEAD(ft)

0.00.73.34.96.68.29.8

11.513.115.7

FLOW RATE(gph)

26422325198216381295978700462264

0

HEAD(ft)

0.01.63.34.96.68.29.8

11.513.115.7

PG 2700Watts: 120 Amps: 1.1Voltage: 120V 60HzHorse Power: 0.16HPInlet/Outlet: 11/4”Flexible Tube Size: 1” or 1 1/4” ID

PG 4500Watts: 220 Amps: 2.0Voltage: 120V 60HzHorse Power: 0.30HPInlet/Outlet: 11/2”Flexible Tube Size: 1 1/4” or 1 1/2” ID

FLOW RATE(gph)

44914227383133292814225917831347951608357

0

HEAD(ft)

0.01.63.34.96.68.29.8

11.513.114.816.419.4

PG 5300Watts: 310 Amps: 2.7Voltage: 120V 60HzHorse Power: 0.42HPInlet/Outlet: 11/2”Flexible Tube Size: 1 1/4” or 1 1/2” ID

FLOW RATE(gph)

52845020475644124042362031972721221917171189793476238

0

HEAD(ft)

0.01.63.34.96.68.29.8

11.513.114.816.418.019.721.324.0

PG 6600Watts: 325 Amps: 2.90Voltage: 120V 60HzHorse Power: 0.45HPInlet/Outlet: 2”Flexible Tube Size: 11/2” or 2” ID

FLOW RATE(gph)

660555484808420136203065252320051480991594264

0

HEAD(ft)

0.03.04.96.68.29.8

11.513.114.816.418.220.322.6

ALL Pro Series

0 300 600 900 1200 1500 1800 2100 2400 2700

18

16

14

12

10

8

6

4

2

0

FLOW RATE (gph)

HE

AD

(ft)

PG 1600PG 2700

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

24

20

18

16

14

12

10

8

6

4

2

0

FLOW RATE (gph)

HE

AD

(ft)

PG 6600PG 5300PG 4500

• Warranty period starts from date of purchase and must be validated with copy of original purchase receipt. • Warranty requests by phone will not be honored. • Warranty items returned without copy of original purchase receipt will not be honored. • Products purchased from eBay, craigslist, etc cannot be honored for warranty unless returned through original purchaser

.esahcrup fo foorp htiw•

• All items must first be returned to Lifegard Aquatics for inspection, evaluation, and processing to determine if product qualifies for warranty replacement or repair. No warranty (repair, replacement, or credit) will be issued prior to inspection of product Please contact us first for warranty assistance. Many times the product can be repaired without the cost and. time involved in sending it back to us. If absolutely necessary, return product freight prepaid to the following address for warranty evaluation and processing.

Lifegard Aquatics Cerritos, CA 90703 moc.scitauqadragefil@ofni :liamE 9514-404)265( xaF

3 year warranty from date of purchase on Quiet One Pump Motors Only.60 day warranty from date of purchase on Shafts and Impellers for All Types of Pumps.60 day warranty from date of purchase on all Ultraviolet Bulbs.60 day warranty from date of purchase on all Test Strips.

••••• 1 year warranty from date of purchase on All Other Products including PG Pumps, LED Lights, Heaters.

.

Pump Maintenance: This pump design features a water lubricated ceramic bearing and shaft for long lasting service. However, the rotor assembly is susceptible to failure if sand or extra fine grit is being pumped.

forming any maintenance or handling. · CAUTION: Always disconnect the pump when per· Check the circuit breaker and try another (GFCI) outlet to ensure the pump is getting electrical power. · Check the pump discharge, impeller and tubing for obstructions. · Check the inlet screen to ensure it is not clogged · After removing the volute, rotate the impeller by hand to insure that it can spin freely.

16301 Carmenita Road Tel (562)404-4129

5

DISCLAIMER: Lifegard Aquatics will not be liable for any labor cost of removing or replacing component parts. This shall be the responsibility of the original purchaser, as will be the shipping charge to Lifegard Aquatics facility. Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, should not be relied upon by the user, and are not part of the contract for sale. Seller's and manufacturer's only obligation and buyer's and user's only remedy, shall be for the manufacturer to either replace and/

or repair at the manufacturer's sole discretion the Lifegard product as described above. Neither sellernor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Damage or failure of any part of a unit covered by this warranty, which results from causes directly, or indirectly connected with the installation, operation, environment, use or willful abuse, including without limitations, improper repackaging and damage incurred in shipping is not covered by this warranty. Unless state law provides otherwise, the manufacturer will only be responsible for repair or replacement of any of its products or parts that are found to be defective, and will not bear any cost of any incidental or consequential damages arising out of the occurrence of such defect. Before using, the buyer and user shall determine the suitability of the product for the intended use, and assumes all risk and liability whatsoever in connection herewith. The warranty and remedy described in this limited warranty is an EXCLUSIVE warranty and remedy. IN LIEU of any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED, including but not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This Warranty gives buyer and user specific legal rights, and buyer and user may also have other rights that vary from state to state. Some states donot allow the exclusion or limitations of incidental or consequential damages, so the above limitationor exclusion may not apply to you. Jolie

Prod

ucts,

Inc

jolie_000