Transcript of 5 - LAMP CHANGE
Optical Adjustment
No.11
Agenda
• Lens Line-up• Theatre Lens Searcher• Lens Adjustment• Lamp Line-up• Lamp replacement
– Lamp explosion Video– Protective Suit Kit– Replacement/Disposal
• Lamp Adjustment
Lens Lineup for R2xx
• LKRL-Z114C 1.35 to 1.98• LKRL-Z116C 1.50 to 2.29• LKRL-Z117 1.72 to 2.39• LKRL-Z119 1.81 to 2.94• LKRL-Z122 2.23 to 4.03
Projection ratio
Knob L Knob R
Knob
Lens
bolt
bolt
H Shift Adjustment
V Shift Adjustment
Lens
Knob
Adjustment range:-1/2V to +1/2V
X
Lens center
Picture center
V Shift = -1/2 V
Vista Scope
E-V Shift
X
Lens center
Picture center
V Shift < -1/2 V ( outside the V-shift adjustment range)
Vista Scope
E-V Shift will be outside adjustment range
Down
7m 8m 9m 10m 11m 12m 13m 14m 15m 16m 17m 18m 19m 20m
4.2kW/Gain1.8
20m17.4m3kW/Gain1.8
17.4m14.4m2kW/Gain1.8
14.4m10.2m
4.2kW/Gain1.0
14.8m13m3kW/Gain1.0
13m10.7m2kW/Gain1.0
10.7m7.5m
(Screen width)
Adaptive screen size vs. Lamp line-up
LKRX-2042A : 4.2KW (for R220) (18k)
LKRX-2030A : 3KW (for R210) (13k)
LKRX-2020A : 2KW (for R210) (9k)
Protective Suit Kit
hood Adjuster
Protective SuitFace shield
Wrist guards Wrist guardsGlove Glove
Do not expose the skin (such as neck) to be safe from explosion.
M size:J-7120-330-A
L size :J-7120-340-A
Step1:Loosen screw
Bend the wire in part A.
A
Screw
wire
Anode CathodeLamp
Plastic cover
Step2:Attach the wire in the anode with the screw. (1.4Nm)
Step3:Pull out the lamp from the case. And remove the protective sheet.
Note: The protective sheet ,case ,carton in which the lamp is packed should be used for disposal of used lamp
Step4:Open U4 panel with key
Rotate the cold mirror
Remove the lamp house cover
Cold mirror
U4 panel
Cover Screw
BoltAnode holder
knob
Anode Terminal
Step5:Remove the Bolt from the Terminal
Loosen the knob
Turn over the Anode holder
in the direction of the arrow.
Cathode Terminal
Cathode bolt
B
Lamp
reflector
The lamp must touch the holder
Step6:Loosen the Cathode bolt
Insert part B of the lamp in Cathode
Terminal.
Note: Do not damage reflector
Step7:Return the Holder to original position
Tighten the Knob
Install the wire on the Anode terminal
with the screw. (15Nm)
Tighten the Cathode bolt(1.4Nm)
Note: The lamp must touch the holder
No space between part B of the lamp
and the end face of Cathode Terminal
ALamp
Holder
Wire
Cathode Terminal
Cathode bolt
C
Bolt
Holder
Knob
Wire Anode Terminal
Step8:Return the Cover and the Cold mirror
Close the U4
Disposal of Used Lamp
1,9 2,101) Click the “Maintenance”
2) Click the “RESET”
3) Input “Serial Code”
Ex.7142 2104 1000 0105
4) Click the “CHECK”
3 4
Note: Execute in standby mode
5
5) Click “CLOSE”
6) Click “FUNCTION”
7) Click “ON”
8)Set the lamp power to 100%.
(9) Click “Maintenance”
10) Click “RESET”
6 7
8
1111) Click “START”
The lamp adjustment mode is started.
12) Wait for five minutes
13) Adjust the +/-button so that the LCD
display become the maximum.
14) Open the X/Y axis adjustment hole
with key15) Adjust the X/Y axis so that the LCD display become the maximum 16) Adjust the +/-button so that the LCD display become the maximum again17) Click “SAVE”18) Close all doors19) Wait for five minutes20) Click “CALIBRATE”
13,16
LCD
U4
X axis screw
Y axis screw
Key
17
Note: 10 minutes or more aging time is required before calibration
“CALIBRATE”: The best brightness of each function memory is set again. The button is recommended to be clicked once a week.