5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to...

11
132 Product overview • 2013 We reserve the right to change designs and technical specifications of our products. Accessories for Sanitary Installations Flamco’s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the safety valve will open to prevent a further rise in pressure. Prescor valves are produced in a variety of fitting sizes and pressure ratings. The materials and construction of Flamco B safety valves are of the highest quality to ensure total safety and peace of mind. They can be used in combination with any boiler system. 5.

Transcript of 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to...

Page 1: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

132 Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

Accessories for Sanitary InstallationsFlamco’s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the safety valve will open to prevent a further rise in pressure. Prescor valves are produced in a variety of fi tting sizes and pressure ratings. The materials and construction of Flamco B safety valves are of the highest quality to ensure total safety and peace of mind. They can be used in combination with any boiler system.

5.

Page 2: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

133

Accessories for Sanitary Installations

Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

5

Accessories for Sanitary InstallationsFlamco’s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the safety valve will open to prevent a further rise in pressure. Prescor valves are produced in a variety of fi tting sizes and pressure ratings. The materials and construction of Flamco B safety valves are of the highest quality to ensure total safety and peace of mind. They can be used in combination with any boiler system.

Page 3: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

134 Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

PRESCOR B

Cap for lifting the valve.

Spring for setting the pressure of the safety valve.

Diaphragm that prevents moisture and dirt from getting

into the moving parts.

Valve with rubber seal.

Prescor Boiler Valves The Highest Quality of System ProtectionThe Prescor B and SB boiler valves protect sealed mains water systems against excess pressure. Such a safeguard is a requirement because of the expansion of system water and the presence of a non-return valve. Of course, water cannot be

compressed, so without this sort of safeguard the pressure in the system could rise to a dangerous level. Local regulations and standards and water pressures must be observed when using Prescor B and Prescor SB valves at all times.

Benefits• Solid brass housing.• Wide range, so the right valve can be used at all

times.• Because of the ''pop'' effect a high blow-off

capacity.• Can be used in combination with any storage boiler

system.• Construction and choice of materials are your

guarantee of safety.

How It WorksWhen the system pressure reaches the set pressure, the Prescor B boiler valve begins to vent, whereby the pressure stops rising. If, due to specific circumstances, the pressure rapidly rises over the set pressure, the Prescor B boiler valve will open fully,

creating a large blow off capacity. This is a permanent, reliable safeguard against overpressure. Venting can be prevented by fitting a suitably sized Airfix expansion vessel for sanitary systems.

All Prescor B and Prescor SB valves are individually tested to guarantee their function, and they comply with European Directive 97/23/EC, the Pressure Equipment Directive.

PRESCOR SB

The valve size of both the Prescor B and the Prescor SB is determined by the capacity

and output of the boiler.

Lifting lever.

The set pressure of the safety valve is locked and

cannot be changed.

To prevent limescale, the moving parts must be kept dry

in all circumstances. The diaphragm

ensures this.

Well Designed Technology and Application The seating of Prescor boiler valves is designed so that it not only makes a perfect seal, but can also achieve a large blow-off capacity. The hardness of the rubber is adapted according to the

set pressure of the safety valve. Due to this combination of a specifically designed seating and special rubber, it is possible to achieve optimum safety.

N.B. Prescor boiler valves must not be installed with the discharge port facing upwards.

OK

XWRONG

Page 4: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

135

Accessories for Sanitary Installations

Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

5

PRESCOR B

Cap for lifting the valve.

Spring for setting the pressure of the safety valve.

Diaphragm that prevents moisture and dirt from getting

into the moving parts.

Valve with rubber seal.

Prescor Boiler Valves The Highest Quality of System ProtectionThe Prescor B and SB boiler valves protect sealed mains water systems against excess pressure. Such a safeguard is a requirement because of the expansion of system water and the presence of a non-return valve. Of course, water cannot be

compressed, so without this sort of safeguard the pressure in the system could rise to a dangerous level. Local regulations and standards and water pressures must be observed when using Prescor B and Prescor SB valves at all times.

Benefits• Solid brass housing.• Wide range, so the right valve can be used at all

times.• Because of the ''pop'' effect a high blow-off

capacity.• Can be used in combination with any storage boiler

system.• Construction and choice of materials are your

guarantee of safety.

How It WorksWhen the system pressure reaches the set pressure, the Prescor B boiler valve begins to vent, whereby the pressure stops rising. If, due to specific circumstances, the pressure rapidly rises over the set pressure, the Prescor B boiler valve will open fully,

creating a large blow off capacity. This is a permanent, reliable safeguard against overpressure. Venting can be prevented by fitting a suitably sized Airfix expansion vessel for sanitary systems.

All Prescor B and Prescor SB valves are individually tested to guarantee their function, and they comply with European Directive 97/23/EC, the Pressure Equipment Directive.

PRESCOR SB

The valve size of both the Prescor B and the Prescor SB is determined by the capacity

and output of the boiler.

Lifting lever.

The set pressure of the safety valve is locked and

cannot be changed.

To prevent limescale, the moving parts must be kept dry

in all circumstances. The diaphragm

ensures this.

Well Designed Technology and Application The seating of Prescor boiler valves is designed so that it not only makes a perfect seal, but can also achieve a large blow-off capacity. The hardness of the rubber is adapted according to the

set pressure of the safety valve. Due to this combination of a specifically designed seating and special rubber, it is possible to achieve optimum safety.

N.B. Prescor boiler valves must not be installed with the discharge port facing upwards.

OK

XWRONG

Page 5: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

136 Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

PRESCOR B SAFETY VALVES

For protecting water heaters and potable water systems.

Prescor B

Type Set pressure

[bar]

Connection Capacity[kW]

OrderCode

Inlet Outlet

Prescor B 1/2 6.0 1/2" F 1/2" F 75 50 27100Prescor B 1/2 8.0 1/2" F 1/2" F 75 50 27101Prescor B 1/2 10.0 1/2" F 1/2" F 75 50 27102Prescor B 3/4 6.0 3/4" F 1" F 150 40 27110Prescor B 3/4 7.0 3/4" F 3/4" F 150 40 28233Prescor B 3/4 8.0 3/4" F 1" F 150 40 27111Prescor B 3/4 10.0 3/4" F 1" F 150 40 27112Prescor B 1 6.0 1" F 1 1/4" F 250 16 29005Prescor B 1 7.0 1" F 1 1/4" F 250 16 28993Prescor B 1 8.0 1" F 1 1/4" F 250 16 29006Prescor B 1 10.0 1" F 1 1/4" F 250 16 29007

Prescor SB

Type Set pressure

[bar]

Connection Capacity[kW]

OrderCode

Inlet Outlet

Prescor SB 1 1/4 6.0 1 1/4" F 1 1/2" F 350 1 29008Prescor SB 1 1/4 8.0 1 1/4" F 1 1/2" F 350 1 29009Prescor SB 1 1/4 10.0 1 1/4" F 1 1/2" F 350 1 29010Prescor SB 1 1/2 6.0 1 1/2" F 2" F 600 1 29011Prescor SB 1 1/2 8.0 1 1/2" F 2" F 600 1 29012Prescor SB 1 1/2 10.0 1 1/2" F 2" F 600 1 29013Prescor SB 2 6.0 2" F 2 1/2" F 900 1 29015Prescor SB 2 8.0 2" F 2 1/2" F 900 1 29016Prescor SB 2 10.0 2" F 2 1/2" F 900 1 29017

AIRFIXCONTROL

With this component the flushing function is fully guaranteed. When the vessel is disconnected from the system, the system flow remains in function.AirfixControl enables an easy yearly precharge check of the Airfix A or D expansion vessel.

AirfixControl

Type OrderCode

AirfixControl 1 28930

Nr. 0343

Nr. 0343

Page 6: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

137

Accessories for Sanitary Installations

Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

5

WALL MOUNTING

Flexcon DT

To assist in mounting and removing Flexcon and Airfix vessels.

A

Type Application DimensionsA

[mm]

OrderCode

Flexcon DT Flexcon/Airfix 2 - 25 350 1 27925

SB-A Band

For mounting an Airfix P expansion vessel (2 - 35 litres) to the wall.

Type Application OrderCode

SB-A Band for fitting Airfix P vessels, to be combined with MB-2

5 27914

MB

For mounting Flexcon/Airfix vessels of 8 - 25 litres. Provided with a slot into which the Flexcon vessel clamp ring fits precisely. Tightening the two bolts is all that is needed to make a sturdy connection.

• Material: DC01 A-m, zinc coated.• Connection to the wall with two Ø8 plugs and two Ø6 screws with hexagon head (wrench 10).• Connection of the vessel to the MB by means of two M5 bolts with cross head.• Separately available are sets of 5 hose clamps for connection vessels without clench ring (size approx. Ø 325 mm).• With spring and adapter for even more installation convenience.

A

B

C

Type Dimensions OrderCode

A[mm]

B[mm]

C[mm]

Flexcon vessel support MB 2 94 113 26 25 27913Flexcon vessel support MB 3 94 113 26 25 27903

Page 7: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

138 Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

SAFETY GROUPS

For protecting the potable water system from excess pressure during the heating cycle.A non-return valve with inspection port will prevent the water (e.g. from a water heater) from flowing back into the mains water pipe.

Prescor IC ¾"Prescor IC ½"

0.1

0.2

0.3

0.4

0.50.60.70.80.91.0

1.5

2.0

0.2 0.4 0.80.6 5421 6 7 8 93 10

Δ P

ress

ure

(bar

)

Capacity (m3/h)

Prescor IC

Type For storagevesselsup to

[l]

Set pressure

[bar]

Connection*[mm]

OrderCode

Prescor IC 1/2 - solder 200 8 15 w x 15 w x 22 c 20 27172Prescor IC 1/2 - compression 200 8 15 c x 15 c x 22 c 20 27173Prescor IC 3/4 - solder 1000 8 22 w x 22 w x 28 c 1 27191Prescor IC 3/4 - compression 1000 8 22 c x 22 c x 28 c 1 27190

* c = compression connection w = solder connection

Flexbrane

Type Set pressure[bar]

Connection OrderCode

Flexbrane CE-H 3/4 hor. 7 3/4" F x 3/4" M x 1" M 1 28388Flexbrane SST NF - ACS 7 3/4" F x 3/4" M x 1" M 20 28365Flexbrane CF 1 hor. 7 1" F x 1" M x 1" M 1 28387Plastic siphon for CE andconnection piece

7 1" x 1" 1 27184The tundish can be rotated through 360°. Hence it can be fitted in almost any position.Compact model, modern design.

Combination Pressure Relief Valves and Safety Groups Apart from the Prescor B and Prescor SB boiler valves, Flamco also supplies different types of Prescor IC and Flexbrane safety groups.

The Benefits of Prescor IC ½".• Sound-class 1 approved.• KIWA/Belgaqua certifi ed.• With ½" – 15 mm compression fi tting.• Large fl ow capacity, so hardly any loss of pressure

through the outlet.• Tundish can be rotated through 360°. Hence it can

be fi tted in almost any position.• Compact, so recommended for built-in appliances.

PRESCOR IC

Block and bleed valve.

Non-return valve prevents water flowing back into the supply line. Opening for the non-return valve at the back.

Relief valve.

Tundish.

Flamco Safety Groups For Effective Safeguarding of Your System

FLEXBRANE

Page 8: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

139

Accessories for Sanitary Installations

Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

5

SAFETY GROUPS

For protecting the potable water system from excess pressure during the heating cycle.A non-return valve with inspection port will prevent the water (e.g. from a water heater) from flowing back into the mains water pipe.

Prescor IC ¾"Prescor IC ½"

0.1

0.2

0.3

0.4

0.50.60.70.80.91.0

1.5

2.0

0.2 0.4 0.80.6 5421 6 7 8 93 10

Δ P

ress

ure

(bar

)

Capacity (m3/h)

Prescor IC

Type For storagevesselsup to

[l]

Set pressure

[bar]

Connection*[mm]

OrderCode

Prescor IC 1/2 - solder 200 8 15 w x 15 w x 22 c 20 27172Prescor IC 1/2 - compression 200 8 15 c x 15 c x 22 c 20 27173Prescor IC 3/4 - solder 1000 8 22 w x 22 w x 28 c 1 27191Prescor IC 3/4 - compression 1000 8 22 c x 22 c x 28 c 1 27190

* c = compression connection w = solder connection

Flexbrane

Type Set pressure[bar]

Connection OrderCode

Flexbrane CE-H 3/4 hor. 7 3/4" F x 3/4" M x 1" M 1 28388Flexbrane SST NF - ACS 7 3/4" F x 3/4" M x 1" M 20 28365Flexbrane CF 1 hor. 7 1" F x 1" M x 1" M 1 28387Plastic siphon for CE andconnection piece

7 1" x 1" 1 27184

Page 9: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

140 Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

Prevent Water Hammer Simply and EffectivelyThe Flexofit water hammer arrestor has been specially developed to absorb water hammer in sanitary mains water systems and is made of chrome-plated brass.

Some Possible Causes of Water Hammer• A valve (or solenoid) or tap closing too quickly.• The non-return valve.• A pump that suddenly cuts in or out.

Pressurized gas cushion.

Rubber diaphragm.

Water at system pressure

T-piece.

The Flexofit water hammer arrestor absorbs the wave of pressure before it can develop into water hammer. The Flexofit does this by having two areas that are separated by a rubber diaphragm. On one side, there is a gas cushion under pressure, while the other side is in connected to the system. The gas cushion compresses and absorbs the wave of pressure.

A Flexofit in the line leading to a urinal flusher

In combination with a wash hand basin Used with a washing machine

FLEXOFIT T-PIECE

Water hammer can be described as a change in pressure in a sealed pipeline as a consequence of sudden changes in the flow speed of fluid in the system. This creates a wave of pressure that moves rapidly through the line. This wave of pressure may result in the creation of vibrations, noise or even a fracture in the pipe or serious damage to equipment and pumps. It is thus important to prevent water hammer.

Selection Table

System pressure [bar] 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7

Pipe diameter Max. pipe length up to the 1st bend

[m]

Number of Flexofi t S water hammer arrestors to be fi tted

½" (15 mm) 15 1 1 1 1 1 1 1 2 2 2 220 1 1 1 1 1 2 2 2 2 - -30 1 1 2 2 2 2 2 2 - - -

¾" (22 mm) 7.5 1 1 1 1 1 1 1 2 2 2 215 1 1 2 2 2 2 2 - - - -20 2 2 2 2 2 - - - - - -

1" (28 mm) 7.5 1 1 1 1 1 2 2 2 2 - -15 2 2 2 2 2 - - - - - -20 2 - - - - - - - - - -

1¼" (35 mm) 7.5 2 2 2 2 2 2 - - - - -

This table is based on a flow rate of 3 m/s.

Page 10: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

141

Accessories for Sanitary Installations

Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

5

Prevent Water Hammer Simply and EffectivelyThe Flexofit water hammer arrestor has been specially developed to absorb water hammer in sanitary mains water systems and is made of chrome-plated brass.

Some Possible Causes of Water Hammer• A valve (or solenoid) or tap closing too quickly.• The non-return valve.• A pump that suddenly cuts in or out.

Pressurized gas cushion.

Rubber diaphragm.

Water at system pressure

T-piece.

The Flexofit water hammer arrestor absorbs the wave of pressure before it can develop into water hammer. The Flexofit does this by having two areas that are separated by a rubber diaphragm. On one side, there is a gas cushion under pressure, while the other side is in connected to the system. The gas cushion compresses and absorbs the wave of pressure.

A Flexofit in the line leading to a urinal flusher

In combination with a wash hand basin Used with a washing machine

FLEXOFIT T-PIECE

Water hammer can be described as a change in pressure in a sealed pipeline as a consequence of sudden changes in the flow speed of fluid in the system. This creates a wave of pressure that moves rapidly through the line. This wave of pressure may result in the creation of vibrations, noise or even a fracture in the pipe or serious damage to equipment and pumps. It is thus important to prevent water hammer.

Selection Table

System pressure [bar] 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7

Pipe diameter Max. pipe length up to the 1st bend

[m]

Number of Flexofi t S water hammer arrestors to be fi tted

½" (15 mm) 15 1 1 1 1 1 1 1 2 2 2 220 1 1 1 1 1 2 2 2 2 - -30 1 1 2 2 2 2 2 2 - - -

¾" (22 mm) 7.5 1 1 1 1 1 1 1 2 2 2 215 1 1 2 2 2 2 2 - - - -20 2 2 2 2 2 - - - - - -

1" (28 mm) 7.5 1 1 1 1 1 2 2 2 2 - -15 2 2 2 2 2 - - - - - -20 2 - - - - - - - - - -

1¼" (35 mm) 7.5 2 2 2 2 2 2 - - - - -

This table is based on a flow rate of 3 m/s.

Page 11: 5....137 Accessories for Sanitary Installations Product overview • 2013 We reserve the right to change designs and technical specifications of our products. 5 WALL MOUNTING Flexcon

142 Product overview • 2013 We reserve the right to change designs and technical specifications of our products.

FLEXOFIT S WATER SHOCK ARRESTOR

Flexofit S absorbs water hammer in order to minimize noise and damage to the system.

• Solid brass, chromium plated housing.• Maximum working pressure: 10.0 bar.• Maximum working temperature: 90 °C (363 K).

Flexofit S

Type Pre-charge[bar]

Dimensions Connection OrderCode

Ø[mm]

H.[mm]

Flexofit S 1/2 2 83 102 1/2" M 20 24980

Flexofit S T-fitting

For mounting Flexofit water hammer arrestors quickly and easily between the tap and the washing machine or dish-washer.

Type Connection OrderCode

T-fitting Flexofit S 3/4" F x 1/2" F x 3/4" M 1 24985

VESSEL CARRIER

Vessel Carrier

A handy vessel carrier which makes it very easy and safe to handle or transport the exchanged vessel.

• Easy to use.• Prevents spilling of (polluted) heating installation water in your transporter or at home with the customer.• The vessel can be handled with one hand only.• Easy to be mounted and removed (for multiple use).

Type Connection Application OrderCode

Vessel carrier 3/4" Flexcon/Airfix 2 - 25 1 27902