4th Quarter Magazine downloadable

24

Transcript of 4th Quarter Magazine downloadable

Page 1: 4th Quarter Magazine downloadable
Page 2: 4th Quarter Magazine downloadable

2 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Page 3: 4th Quarter Magazine downloadable

3THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Page 4: 4th Quarter Magazine downloadable

4 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

2013 IIEE BOARD OF GOVERNORS AND OFFICERS

National President Gregorio R. CayetanoVP-Internal Affairs Alex C. CabugaoVP-External Affairs Ma. Sheila C. CabarabanVP-Technical Affairs Larry C. CruzNational Secretary Florigo C. VaronaNational Treasurer Angel V. De Vera, Jr.National Auditor William J. JuanGovernor-Northern Luzon Freddie O. OrperiaGovernor-Central Luzon Virgilio S. LuzaresGovernor-Metro Manila Eusebio A. GonzalesGovernor-Southern Luzon Amando A. PlataGovernor-Bicol Ariel O. SorianoGovernor-Western Visayas Noel L. OleaGovernor-Eastern/Central Visayas Cleofe T. CaidicGovernor-Northern Mindanao Gino B. MacapayagGovernor-Southern Mindanao Fritzelou E. ArriateGovernor-Western Mindanao Richard O. LizardoImmediate Former President Jules S. AlcantaraExecutive Director Ramon P. Ayaton

IIEE NATIONAL SECRETARIAT DEPARTMENT HEADS

Administrative Niellisa Joy B. BandongTechnical Ma. Elena U. LiongsonMarketing Allen M. PidoMembership Marjorie Aguinaldo-MuñozFinance-OIC Emee F. Sulit

Mission“To deliver high-quality products and services in order to instill excellence in the Electrical Practitioner, and to enhance the technical profession to enable it to make positive contributions to national

development.”

Vision“To be the best and most prestigious professional technical organization in the

Philippines.”

I - ntegrityI - nnovationE - mpowermentE - xcellence

The views and opinions expressed by the authors of letters, articles and research studies published in The

Electrical Engineer DO NOT necessarily reflect the views of the Institute of Integrated Electrical Engineers of the Philippines, Inc. (IIEE). The IIEE trusts the integrity of these authors. The IIEE exercises due review diligence but it is possible that the contents of the articles contributed may not be verified due to time constraints. Articles or visual materials may not be reproduced without written consent from IIEE. The IIEE reserves the right to accept or refuse submitted materials for publication. Articles, reactions and feedback from readers may be sent through e-mail at [email protected].

Contents

6

8

10

11

12

17

22

From the Office of the National President

President’s Report

Under the IIEE Spotlight

38th IIEE Annual National Convention and 3E XPO

IIEE First Western Mindanao Regional Conference Amidst the War

2013 Turnover Ceremonies and Tribute to IIEE Valued Exhibitors

Cover Story

Climate Change: A Larger Global Issue

Technical Feature:

- Electric Motor TestingThe Missing Link of Condition Monitoring

- Calculation of Minimum Vegetation Clearance Distance (MVCD) to Overhead Power Lines

Page 5: 4th Quarter Magazine downloadable

5THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

PUBLICATIONS COMMITTEE

Chairman: Rolito C. Gualvez Vice Chairman: Ronald Vincent M. SantiagoMembers: Cyrus V. Canto Marvin H. Caseda Glynn Andy O. Gayman Allan C. Nerves

Roland P. VasquezOverseer: Larry C. Cruz

The ELECTRICAL ENGINEER

The Electrical Engineer is published quarterly by the Institute of Integrated Electrical Engineers of the Philippines, Inc. (IIEE), with editorial and business offices at #41 Monte de Piedad St., Cubao, Quezon City, Philippines. Tel Nos. (632) 722-7383, 727-3552, 412-5772, 414-5626, Fax Nos. (632) 721-6442 & 410-1899. Website: www.iiee.org.ph; E-mail: [email protected].

The present circulation of the magazine is 35,000 copies per issue to members and industry stakeholders.

THE ELECTRICAL ENGINEER Editorial Board

Chairman: Larry C. CruzEditor-in-Chief: Rolito C. GualvezAssociate Editor: Ronald Vincent M. Santiago Technical Consultant: Allan C. NervesAdministrative Officer: Ramon P. Ayaton

Editorial Staff

Editorial Assistant Ana Kristina Cezele B. Besa

Advertising and Marketing

Account Executive Mary Grazellen C. Jose 727-3552 loc. 100 721-6442 / 410-1899

EditorialGetting involved with Climate Change

Countries all over the world face the impacts of the fast-changing climate events. In a guide of UN Habitat entitled “Planning for Climate Change”, it is said that “Climate change is fast becoming one of the most significant challenges of the 21st century”.

Climate change impacts both people and ecosystems, and its effects vary in different ways. It is affecting every part of the globe. Recently, the Philippines was devastated by Typhoon Yolanda (Typhoon Haiyan), which left thousands of casualties, and with survivors struggling to rebuild homes and also their lives from the damage it caused. While there are arguments with regards to extreme weather connecting to climate change, Representative for the Philippines Naderev Sano said at the UN Climate Change that what the country has gone through is a result of extreme climate event.

It is a complicated problem that brought extreme weather events to different parts of the world, and it has been deliberately discussed both locally and internationally.

One thing is certain: greenhouse gases continuously warm up the earth with its effects to be felt for the next years or even decades. However, something can be done about it.

Energy efficiency and renewable energy can be a remedy to this global dilemma. Let us do our share to help save the earth we are living in.

- The Electrical Engineer Editorial Board

About the Cover

Climate change is the theme for the 4th Quarter issue of The Electrical Engineer Magazine. The Earth is the cover page of this issue for it has been experiencing extreme climatic events. According to studies, some of these events are caused by human activities.

Page 6: 4th Quarter Magazine downloadable

6 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

From the Office of the National President

President’s Report

IIEE GOVERNANCE

On October 9, 2013, IIEE Marketing Department together with the Executive Director went to Microtel Hotel, Coral Way St. to attend the Briefing of Exhibitors for the IIEE’s 38th Annual National Convention and 3E XPO, Electrical, Electronics and Energy Exposition.

On October 16, 2013, the BOG attended the Second Professional Summit as per invitation of the Professional Regulation Commission to the officers of the Institute of Integrated Electrical Engineers of the Philippines, Inc.

I graced the meeting of the Philippine Technological Council on October 22, 2013 as a Member Trustee.

On November 8, 2013 together with CNP Raymond Marquez and Jessie Todoc of ICA, we met Mr. Matthieu Penot of European Union at the RCBC Plaza with regards to the finalization of the grant of EU to IIEE on the Deployment of High Efficiency Motors in the Philippines. With the invitation from the International Copper Association, I together with the CNP Member Engr. Arthur A. Lopez went to Thailand for the European Union’s Energy Efficient Air Conditioners in ASEAN. The meeting was held last November 14-15, 2013.

On November 25, 2013 I attended the training at RCBC Plaza provided by EU for non- government organization. This is regarding the grant of EU for the Promotion and Deployment of Energy Efficient Motors in the Philippines to IIEE.

Last December 10, 2013, I attended the ASEAN SHINE Launching in cooperation with International Copper Association at F1 Hotel, Bonifacio Global City, Taguig.

PRIORITY PROJECTS

To cope up with the demands for technological breakthroughs and professional advancement, we have created timely and relevant Priority Projects of the IIEE.

1.) Membership to ASEAN Engineer Register, ASEAN Chartered Professional Engineer Register (ACPER) and Asia Pacific Economic Cooperation Engineer (APEC Engineer).

Being the core of my leadership, I was very grateful that officers led the application for ACPER. As of the moment, we have a total of 13 applicants from BOG (3), ACPER Committee (3), BEE (3), CNP (2) and members (2). Since our borders will open to fellow electrical practitioners in ASEAN and borderless mobility of engineering services will take effect, 2013 is indeed the perfect time acquire ACPE members through the efforts of its Chairman, Engr. Cirilo C. Calibjo Jr., PEE, PhD.

On the other hand, if the electrical practitioners wanted to practice in the United States of America, Australia, Japan, etc., they must be accredited as APEC Engineer. CHED, PRC and PTC are the accrediting bodies for APEC Engineer.

2.) Improvement of IT Infrastructure. In order to facilitate faster transactions during the three-day convention, IIEE launched the first online registration “TAP and CLICK” to achieve a hassle-free registration and avoid lengthy time of waiting. Through an e-card, a member can automatically register and can immediately proceed to the payment counter.

Furthermore, online registration was also applied during technical sessions for the delegates’ CPD points.

3.) Widest Dissemination of Electrical Safety Enhancement and Awareness (ESEA). Since the Electrical Safety Inspection is the most basic step to achieve the Electrical Safety Awareness and to enforce it, the Electrical Safety Enforcement and Awareness Committee had formulated a training program for the benefit of the Electrical Safety Enforcement Authority. The Association of City Municipal Electrical Engineers and Electricians (ACMEE), an association whose members are mainly Local Government Electrical Inspectors, together with the IIEE Academic Affairs Committee were the program developers. It touches almost every aspect of the Electrical Inspection, basic knowledge and experiences of the participants as well as the speakers. The primary objective of the program is to standardize the electrical inspection process in which Electrical Safety Enforcement Authorities and other related studies are involved.

Moreover, the “Training the Trainers” Program was attended by sixteen (16) representatives coming from different regions which were held last November 21-23, 2013 at the IIEE National Office.

My warmest greetings to my fellow electrical practitioners! As this year marks the 38 fruitful years of our beloved Institute, I would like to commend the officers and general membership for making my leadership a successful milestone of IIEE. With your unwavering support, IIEE is now

eyeing for more success in the years to come.

For the fourth quarter issue of the Electrical Engineer Magazine, the core of my report will focus on the relevant achievements of the priority projects that transpired during the last quarter of my term as National President. Thus, learning and experiences of this year will serve as valuable assets to the future leaders to move forward and sustain the excellence of our profession.

Page 7: 4th Quarter Magazine downloadable

7THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

President’s Report

4.) Update of Qualified Barangay Electricians to Become Registered Master Electricians (RME) and RME to become REE. The program has a primary purpose of serving as an adjunct between the licensed electrical engineers and master electricians on one hand and the practicing unlicensed electricians on the other, to upgrade the competence of unlicensed electricians by IIEE- initiated intervention trainings, seminars and conferences, to identify qualified unlicensed electricians for possible RME training and review and lastly, to identify and seek partnership from other stakeholders of the electrical industry from public or private entities for electricians’ upgrading.

The strategies and implementation involves database collection of electricians information, obtain best practices of electrician upgrading in the local chapter level, formulate a standardize national curriculum for the academy, initiate accreditation of electricians to the city by adopting the IIEE North Davao Chapter model, identify service providers and process them for accreditation and identify donors and benefactors for support of the academy.

Enrollment to the academy requires different levels of studies and experiences such as: (a) High School Graduate with 5 years experience; (b) One (1) Year Vocational Course with 3 years experience; (c) 2 Year Vocational Course with 2 Years experience; and, (d) 3 Year Vocational Course/Undergraduate or Graduate of EE Course with 1 Year Experience.

Last year, IIEE and NEA have inked a Memorandum of Understanding in a meeting in Davao City that the latter would support technically and financially to the program.

5.) Balik Liwanag Program as Banner Program for Corporate Social Responsibility

This is the banner program to alleviate the effects of calamities and flooding brought about by strong typhoons and other force majeure, thus, the Institute has to allocate funds to restore the affected areas. As part of IIEE’s corporate social responsibility, nine (9) regions remitted 3% share from the net proceeds of their respective conferences and 5% share from the net proceeds of National Midyear Convention and Annual National Convention.

REGULAR EXECUTIVE MEETING AND REGULAR BOARD MEETING

As member of the Executive Committee, we had conducted meetings in the following dates: (a) October 5, 2013, (b) November 2, 2013 and (c) December 7, 2013 as well as special meetings last: (a) December 10, 2013, (b) December 11, 2013, (c) December 12, 2013, (d) December 19, 2013, and (e) December 27, 2013.

On the other hand, the Board of Governors conducted the 10th Regular Board Meeting last October 19, 2013 at the Yakan Function Room, Garden Orchid Hotel, Zamboanga City and the 11th Regular Board Meeting was held last November 27, 2013 at the Microtel Hotel, Pasay City. Finally, the 12th Regular Board Meeting was conducted last

December 14, 2013 at the IIEE National Office.

REGIONAL CONFERENCE AND ANNUAL NATIONAL CONVENTION

Apart from regular meetings, the Board of Governors also attended regional conference and Annual National Convention as follows:

1. 1st Western Mindanao Regional Conference held last October 18-19, 2013 at the Garden Orchid Hotel, Governor Camins Road, Zamboanga City. 2. 38th Annual National Convention held last November 27-30, 2013 at the SMX Convention Center, Pasay City.

IIEE COUNCIL OF STUDENT CHAPTERS

The Student Affairs Committee in cooperation with the Council of Student Chapters successfully conducted the National Math Wizard Competition and National Quiz Show last November 27, 2013 at the SMX Convention Center, Pasay City. For NQS, winners are the following:

Over-All Champion – Cebu Technological University1st Runner-Up – Mindanao State University (General Santos City)2nd Runner-Up – Camarines Norte State College

On the other hand, National Math Wizard is composed of the following winners:

Over-All Champion – Polytechnic University of the Philippines (Sto. Tomas Batangas)1st Runner-Up – Cagayan State University2nd Runner-Up – Holy Angel University

2013 is just a beginning of prolific years where successful milestones are set to unfold and a significant history among the lives of electrical practitioners around the globe.

May the Almighty God continue to shower His blessings to the Institute and to the General Membership.

Maraming Salamat at Mabuhay ang IIEE!

Engr. Gregorio R. Cayetano Sr.2013 IIEE National President

Page 8: 4th Quarter Magazine downloadable

8 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 20138 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Under the IIEE Spotlight

at the SMX Convention Center, MOA, Pasay CityNovember 27 - 30

Annual National Convention and 3E XPO38th

Page 9: 4th Quarter Magazine downloadable

9THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013 9THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Under the IIEE Spotlight

Annual National Convention and 3E XPO

Page 10: 4th Quarter Magazine downloadable

10 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Under the IIEE Spotlight

Dawn of September 9, 2013, the Zamboanga Stand-off commenced, armed forces from the Moro National Liberation Front (MNLF) siege the City. The economy

of Western Mindanao was practically paralyzed, according to the Bangko Sentral ng Pilipinas over PhP 60 Billion amount of money stop circulating as nothing goes in and out of Zamboanga City during these times. Residents outside the conflict area were not going out of their homes while two hundred thousand plus evacuees flocked about 35 evacuation centers in the City. Hundreds of hostages were held as human shield by the MNLF rebel group. Offices, malls, commercial stores, hardwares, and groceries in the city proper were closed, the City was running out of food, cargo vessels, passenger ships and commercial airlines were not allowed to go in and out of Zamboanga City which accounts for 40 percent of gross regional domestic product and home to 16 canning factories supplying 80 percent of the country’s sardines.

Conflagrations, cannons and mortars coupled with air strikes have become common even in such unholy hour of the night. Exchange of gun fires between the government forces and the MNLF had been twenty-four hours nonstop. Helicopters were all over the area. Zamboangueños were living in fear as nobody knows when the conflict will end. It took so much courage from the IIEE Western Mindanao Regional Governor to call upon the ZAMBASULTA Chapter officers for a meeting in the middle of the warfare with the agenda of pushing through with the First Western Mindanao Regional Conference.

The IIEE Western Mindanao Officialdom braved the possibility of being hit by gunshots coming from the firefight between the MNLF and government compounded by the long queues for checkpoint in strategic places scattered all over Zamboanga City, as well as numerous car bombing purportedly propagated by MNLF forces on the run. It was good that the officers were equally valiant and one with the decision of the Regional Governor in holding the regional conference.

As such, the Institute of Integrated Electrical Engineers of the Philippines Incorporated (IIEE) – Western Mindanao Region held its “1st Regional Conference” last October 17-19, 2013 at the Garden Orchid Hotel Gov. Camins Ave., Zamboanga City which was bannered by the theme “Leading Electrical Practitioners Towards Global Recognition”

This conference served as a grand gathering of more than two hundred (200) electrical practitioners and notable electrical engineers coming

from the different five chapters of the region from the Cities of Zamboanga, Pagadian, Dipolog, Ozamis, Oroquieta, Tangub, Isabela, Lamitan and Provinces of Zamboanga del Sur, Zamboanga del Norte, Zamboanga Sibugay, Misamis Occidental, Basilan, Sulu and Tawi-Tawi.

The activity was graced by the Professional Regulatory Board of Electrical Engineering in the person of Hon. Jaime V. Mendoza, PEE, MTM, FIIEE and Hon. Francis V. Mapile, PEE, BBM, FIIEE, the IIEE Board of Governors headed by the National President himself, Engr. Gregorio R. Cayetano, Respected Electrical Engineering Practitioners who served as technical speakers as well as exhibitors from leading electrical companies in the country also participated in this event.

The three-day affair begun with the building wiring, industrial motor control skills competition and sports activities followed by the official opening of the First Western Mindanao Regional Conference (WMRC) which was highlighted by the address coming from the First Regional Governor of Western Mindanao, Engr. Richard O. Lizardo who eloquently narrated the emotional and physical torments in going through with the ground works just to realize first WMRC. It was indeed not an easy decision to proceed with the activity considering the man-made and natural calamities that besieged the City of Zamboanga one month prior to the conference. Gov. Lizardo and the officers of ZAMBASULTA Chapter continued with the meetings and never faltered despite the unnerving sound of mortars and M203 between the government forces and the MNLF during the preparation days. All other professional organizations that had set Zamboanga City as a venue for their gathering has already cancelled but Gov. Lizardo stood firm and persuaded the IIEE Board of Governors to pursue with this momentous and historical undertaking. Eventually, we were all vindicated for the first WMRC roared with success from all viewpoints; the Board of Governors, the participants, the exhibitors, the speakers and product presenters. This just proves our resilience and dedication towards the ideals Institute.

The success of first WMRC has laid down a clear message for the Electrical Engineers here and abroad that with dedication and hard work all adversaries can be conquered. The creation of the Western Mindanao as a Region is a product of the recent amendment of the IIEE Constitution and By-laws and the first WMRC has shown the wisdom behind such creation. Long Live IIEE!

IIEE First Western Mindanao Regional Conference Amidst the WarBy: Engr. Marli A. De Fiesta

Vice Pres. Int. Affairs ZAMBASULTA Chapter

Page 11: 4th Quarter Magazine downloadable

11THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

2013 Turnover Ceremonies and Tribute to IIEE Valued Exhibitors

Under the IIEE Spotlight

The Institute of Integrated Electrical Engineers (IIEE) of the Philippines, Inc. celebrated 2013 Turn Over Ceremonies and Tribute to IIEE Valued Exhibitors at the National Office

in Cubao, Quezon City on December 14.The main event was preceded by the 12th Regular Board Meeting, with the incoming and outgoing Board of Governors.

Officers, exhibitors, and guests attended the event. A thanksgiving mass took place in the afternoon, which was followed by the main event. IIEE Vice-President for External Affairs Engr. Ma. Sheila C. Cabaraban delivered the welcoming remarks, followed by the acknowledgment of

guests by 2013 Vice-President for Technical Affairs Engr. Larry C. Cruz.

2013 National President Engr. Gregorio R. Cayetano Sr. delivered his valedictory speech, followed by the turnover. Engr. Alex C. Cabugao, 2014 National President, also gave his acceptance speech.

Valued exhibitors were also present at the event. An audio-visual presentation was shown, acknowledging the exhibitors’ support at the tribute to the IIEE Valued Exhibitors. A plaque of recognition was given to each exhibitors for their unending support to the Institute.

The year was filled with significant milestones that are set to embark on a continuing venture towards the success of electrical practitioners around the globe.

In accordance with the IIEE by laws, the IIEE Cagayan de Oro Chapter conducted its 2013 Annual General Membership Meeting and 2014 Election of Officers at Grand Caprice

Convention Center, Limketkai Complex, Cagayan de Oro City on September 21 and was participated by around 100 members including non-paying participants.

Engr. Gregorio R. Cayetano Sr., 2013 IIEE National President (right), and Engr. Alex C. Cabugao, 2014 National President (left). (Photo by Engr. Elmer Casao)

Page 12: 4th Quarter Magazine downloadable

12 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Cover Story

Climate Change: A Larger Global

IssueClimate change is a dilemma that

has been continuously discussed throughout the globe. The

changing climate is mostly a result of human activities for the last hundred years. In WWF’s 2012 Living Planet Report that was published on their website, the world could not sustain the overconsumption of food, materials, fossil fuels, and other non-renewable resources of humanity.

The greenhouse effect is the main cause of global warming; as both global warming and climate change indicate an increase

in the temperature of the Earth. Greenhouse gases such as carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O) and others are contributing to the greenhouse effect. According to the Oxford Dictionaries website, greenhouse effect is “the trapping of the sun’s warmth in a planet’s lower atmosphere due to the greater transparency of the atmosphere to visible radiation from the sun than to infrared radiation emitted from the planet’s surface.” Natural processes and human activities have caused the fluctuation of the amount of heat on Earth.

The effects have been unequivocally noticeable. Different places experience different effects. Countries all over the world have experienced extreme heat, cold, storms, and other climatic events. Thus, climate change is everybody’s problem.

In comparison to before, the Earth’s climate is now changing rapidly.

Typhoon Yolanda: A Dire Effect of Climate Change

Families lost loved ones. Homes were destroyed. Lives were devastated.

On November 2013, Tyhoon Yolanda (with an international name of Typhoon Haiyan) has devastated Central Visayas, and it has been recorded as the world’s strongest storm to make landfall.

Residents of the region, as well as the other residents nearby the area, were religiously warned of the strong typhoon. Public warnings were all over the television and radio stations, and other media. The Philippine Atmospheric, Geophysical Astronomical Services Administration (PAGASA), predicted that the typhoon would be strong; however, the damage that the storm surge has caused, which washed away properties and lives, was unexpected.

Page 13: 4th Quarter Magazine downloadable

13THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Cover Story

“Storm Surge is an abnormal rise of water generated by a storm, over and above the predicted astronomical tide”, according to a presentation entitled “Introduction to Storm Surge” in the National Oceanic and Atmospheric Administration (NOAA)’s National Weather Service website of the United States.

Engr. Cleofe T. Caidic, 2013 IIEE Governor – Eastern/Central Visayas, was also in Tacloban during the typhoon. People were prepared for the strong winds the storm would produce, but were not prepared for the water and the damage the storm surge would cause. “Ine-expect nila ang storm surge, pero hindi naman nila alam kung ano iyon... (They expected that there will be a storm surge, but they didn’t know what it is.)”, Engr. Cleofe said.

Thousands of lives and millions worth of properties have been washed by Typhoon Yolanda. According to Engr. Cleofe, department stores and groceries have opened for the survivors. However, when supplies started to deplete, looting became an issue.

Balik-Liwanag Program

In connection with this, the Balik-Liwanag Program of the Institute of Integrated Electrical Engineers of the Philippines, Inc. (IIEE) caters to help in times of disasters in the country. The Balik-Liwanag Program team, headed by Engr. William J. Juan, 2013 IIEE National Auditor, roamed around Tacloban to assist with the restoration of the damaged electrical systems in the area. They also met with City Mayor Alfred Romualdez to

express the Institute’s willingness to help the affected areas and to discuss the plans of IIEE Balik-Liwanag Program.

Balik-Liwanag Team is of assistance to the city and survivors of the typhoon

IIEE’s role is to inspect applications in power restoration and approval of the city’s applicants for reconnection.

As of December 14, more than 600 households have been inspected by the team.

Changing for the Better

Energy Efficiency and Renewable energy are solutions for climate change.

To cut the greenhouse gas emission, energy must be consumed efficiently. Energy efficiency must be incorporated to daily lives so as to preserve the quality of life that it provides.

Renewable energy, on the other hand, is also a key solution to climate change for it will never run out, unlike other sources of energy that will soon come to depletion. It offers a cost-effective alternative for energy consumption.

Climate change is everybody’s problem because every action affects the world.

Devastation caused by Typhoon Yolanda

Photos by Engr. Cleofe T. Caidic

Page 14: 4th Quarter Magazine downloadable

14 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Mak

e th

e m

ost o

f you

r ene

rgySM

Anyw

here

in th

e w

orld

you

nee

d po

wer

, Sch

neid

er E

lect

ric is

ther

e.P

ower

loss

pos

es a

thr

eat

to t

he e

quip

men

t, pe

ople

, and

pro

cess

es y

ou r

ely

on. A

nd w

ith t

oday

’s s

tric

ter

secu

rity

and

safe

ty

regu

latio

ns, p

roce

ss a

utom

atio

n, a

nd in

crea

sing

dep

ende

nce

on s

ophi

stic

ated

hig

h-te

ch s

yste

ms,

the

nee

d fo

r un

inte

rrup

ted

pow

er is

crit

ical

. Add

the

ris

ing

cost

of e

nerg

y an

d en

viro

nmen

tal c

once

rns

into

the

mix

, and

it b

ecom

es e

ssen

tial t

o pr

otec

t yo

ur p

ower

with

sol

utio

ns t

hat

not

only

mee

t yo

ur a

vaila

bilit

y de

man

ds, b

ut a

re e

nerg

y ef

ficie

nt, t

oo.

Why

Sch

neid

er E

lect

ric is

the

right

pow

er p

rote

ctio

n ch

oice

Yo

u m

ay k

now

us

as t

he m

arke

t le

ader

in d

eliv

erin

g IT

pow

er p

rote

ctio

n. B

ut w

e al

so o

ffer

a fu

ll ra

nge

of r

elia

ble

and

high

ly

effic

ient

pow

er p

rote

ctio

n so

lutio

ns d

esig

ned

to s

afeg

uard

bus

ines

s-cr

itica

l app

licat

ions

and

env

ironm

ents

out

side

the

IT r

oom

. O

ur in

nova

tive,

bes

t-of

-bre

ed p

rodu

cts,

ser

vice

s, a

nd s

olut

ions

pro

vide

the

sec

ure

and

avai

labl

e po

wer

you

nee

d to

kee

p yo

ur

syst

ems

up a

nd r

unni

ng, w

hile

incr

easi

ng e

ffici

ency

, per

form

ance

, and

saf

ety.

Gua

rant

eed

avai

labi

lity

for b

usin

ess-

criti

cal s

yste

ms

No

mat

ter

wha

t in

dust

ry y

ou’re

in, o

ur u

nriv

alle

d po

rtfo

lio o

ffers

a s

olut

ion

that

’s g

uara

ntee

d to

sui

t yo

ur s

peci

fic b

usin

ess

need

s an

d ke

ep y

our

pow

er o

n. T

hank

s to

Sch

neid

er E

lect

ric™

pow

er a

nd e

nerg

y m

anag

emen

t ca

pabi

litie

s, in

-hou

se e

xper

tise,

bro

ad

inve

stm

ents

in R

&D

, and

glo

bal p

rese

nce,

you

hav

e a

trus

ted

reso

urce

for

relia

ble

pow

er, a

nyw

here

in t

he w

orld

.

Secu

re p

ower

sol

utio

ns th

at d

eliv

er th

e pe

rfor

man

ce y

ou

need Pr

oduc

ts: O

ur c

ompl

ete

cata

logu

e of

pow

er s

olut

ions

, fea

turin

g ou

r lea

ding

bra

nds

such

as

APC

by

Schn

eide

r Ele

ctric

™ a

nd G

utor

™, o

ffers

an

unm

atch

ed ra

nge

of

sing

le-

and

thre

e-ph

ase

UPS

uni

ts, r

ectif

iers

, inv

erte

r sys

tem

s, a

ctiv

e fil

ters

, and

st

atic

tra

nsfe

r sw

itche

s fr

om 1

kVA

to s

ever

al M

VAs.

Serv

ices

: Sch

neid

er E

lect

ric C

ritic

al P

ower

& C

oolin

g Se

rvic

es c

an p

roac

tivel

y m

onito

r and

mai

ntai

n th

e he

alth

of y

our s

yste

ms,

pro

tect

ing

your

inve

stm

ents

, re

duci

ng to

tal c

ost

of o

wne

rshi

p an

d op

erat

ing

expe

nses

, and

pro

vidi

ng p

eace

of

min

d th

roug

hout

the

equ

ipm

ent

lifec

ycle

.

Solu

tions

: Cho

osin

g th

e rig

ht c

ombi

natio

n of

pro

duct

s an

d se

rvic

es fr

om

Schn

eide

r Ele

ctric

giv

es y

ou t

he c

onve

nien

ce o

f a to

tal s

olut

ion

– sy

stem

s, s

oftw

are,

an

d se

rvic

es fr

om a

sin

gle

sour

ce.

©20

13 S

chne

ider

Ele

ctric

. All

Rig

hts

Res

erve

d. S

chne

ider

Ele

ctric

, A

PC

, G

utor

, an

d M

ake

the

mos

t of

you

r en

ergy

are

tra

dem

arks

ow

ned

by S

chne

ider

Ele

ctric

Indu

strie

s S

AS

or

its a

ffilia

ted

com

pani

es. A

ll ot

her

trad

emar

ks a

re t

he p

rope

rty

of t

heir

resp

ectiv

e ow

ners

. w

ww

.sch

neid

er-e

lect

ric.c

om •

998

-498

2_P

H

Alw

ays s

ecur

e. A

lway

s ava

ilabl

e.

Lear

n m

ore

abou

t our

secu

re p

ower

solu

tions

.

Dow

nloa

d ou

r FRE

E W

hite

Pap

er #

1, ‘T

he d

iffer

ent t

ypes

of U

PS sy

stem

s’ a

nd g

et a

cha

ngce

to

WIN

1 of

5 A

PC S

urge

Arr

est P

rote

ctio

n PE

R5-C

H.

Vis

it w

ww

.ap

c.co

m/p

rom

o K

ey C

od

e 51

895y

Cal

l 1-8

00-1

441-

0535

Fax

976

9961

The

diff

eren

t typ

es o

f U

PS sy

stem

s

Cont

ents

1

2

7

7

9

10

> E

xecu

tive

sum

mar

y

998-

4982

_PH

_279

x216

.indd

1

13-1

1-25

��

9:38

Page 15: 4th Quarter Magazine downloadable

15THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

• LSIG Protection• Manual and Electrical operated

• Complete series of products• Applicable to industrial,

commercial and residential system

• Available for AC/DC coil voltage• UL, CSA, TUV, IEC Standard

• Compact size: Save 57% space• 50% Less wiring : MCCV+Contractor+TOR g MMS+Contractor

• Overload, short circuit & earth leakage protection• Comply with IEC60898 standard

• Electrical and mechanical interlocking• Automatic and manual available

SHIHLIN ELECTRIC CORP. (Philippine Representative Office)TEL: (632)519-6666 / (632)519-7586FAX: (632)519-7569EMAIL: [email protected]: Unit 1402, Antel Corporate Centre, 121 Valero St., Salcedo Village, Makati City

High Quality & Reliability

Digital controller with accurate setting

Air Circuit Breaker

MCCB / ELCB

Magnetic / Contactor

Manual Motor Starter

MCB / RCBO

ATS

Space saving, Easy mounting, Less wiring

Compact, Simple, User Friendly

Page 16: 4th Quarter Magazine downloadable

Alegria Bldg., 2229 Chino Roces Ave., Makati City

Tel. No.: +63 2 8104058 Fax No.: +63 2 8130341 www.skf.ph

For more information, please contact :

SKF Philippines Inc.

• Integratesawiderangeofelectricaltestsinasingleportableunit.

• Performsinsulationresistance,polarizationindex,dielectricabsorptionstep voltage and surge tests to detect weaknesses and faults in motor windingandgroundwallinsulation.

• Motor circuits can also be analyzed utilizing Resistance, Impedence,Capacitance, Phase Angle and Dissipation Factor/Quality Factor measurements.

• This on-line motor analyzer offers a wide variety of capabilities for the maintenance professional to understand the condition of the over-all system-thepowersupply,theelectricmotorandthemechanicalload.

• It is programmed to supply information on voltage level, voltagebalance, harmonic and total distortion, rotor cage condition, motor efficiency effective service factor, overcurrent, operating condition, torque ripple, load history among others. Thiswide range of testsallows exploration of the true condition of motor integrity andconditionsrelatedtomotorperformance.

• OtherspecialfeaturesoftheEXP4000include:- Torque Module which displays the Torque Ripple and Torque Spectrum

enabling the user to diagnose mechanical issues, transient overloading, mechanical imbalances along with bearing problems, and cavitation, amongothers.

- Transient Analysis module performs a start up analysis which allows the user to visually see the amplitude of voltage, current and torque at startup,alongwithmotorstartuptime.

- VFD module provides a comprehensive diagnosis of motor problems associatedwithvariablefrequencydrives(VFD).

- Motor efficiency assessment & identification of motors performing at sub-par efficiency, and calculates the pay-back period if replaced by a newmotor.

Page 17: 4th Quarter Magazine downloadable

17THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Technical Feature

Condition monitoring is often seen as the use of vibration analysis, thermography, laser alignment and oil analysis. All too often electrical testing is deemed as unnecessary. However, studies show that after bearing failure, electrical faults are the most common mode of motor failure, so a structured electrical testing regime is vital to plant reliability.

The meg-ohm test has long been the tool of choice for engineers, and this simple test is often the only electrical test performed. Whilst the test has a valid role to play, it is not capable of detecting all the likely faults within a motor’s winding.

Modern test equipment utilises PC control to provide automatic testing and fault diagnosis, removing the onus on the operator to interpret the results. The equipment is able to detect micro arcs, and stop the test automatically. Database software allows assets to be saved with all test results, so that a trend can be built up over time, ideally from new.

Automated testing helps remove operator error, inconsistency created by different operators, and the possibility of the operator applying over voltage. The latest testers combine all insulation tests within one portable device, and have the ability to create professional reports.

Static Testing

Static testing is typically performed from the switch room, and should be carried out in a specific test sequence:

Winding resistance test:

Used to highlight dead shorts and loose connections. Tests must be performed with accurate equipment, capable of measuring down to 0.001 ohms. Resistance values must be corrected to a

Electric Motor Testing The Missing Link of Condition Monitoring

Michael Herring, Product Manager EU - Baker Instrument Company, Baker Instrument Company is an SKF Group Company [email protected]

www.bakerinst.com

constant temperature, typically 20 degrees Celsius. The motor temperature must be measured accurately, and where possible, the copper temperature should be used.

A motor that has been recently operating is unlikely to be at ambient temperature, so the use of ambient temperatures should be avoided.

The unbalance between the phase to phase readings is then calculated, with an unbalance of less than 1% typical for a good winding. A connection that is gradually working loose, for example, will show an increasing unbalance over time.

Meg-ohm test:This test will show if the motor has a dead short to earth, is wet or contaminated. A meg-ohm test cannot show if a motor is in good condition, as it does not test the entire insulation system.

PI Test:The PI test is a 10 minute test. It is used to measure the ability of an insulator to polarize. The 10 minute meg-ohm value is divided by the one minute value, and a ratio of 2 or more is typically deemed as acceptable. Some insulation classes accept a lower PI ratio, as do some engineers, depending on the location/application of their motors.

DC Step Voltage Test:This test is typically performed at twice line voltage plus 1000 volts. The voltage is increased in steps, ideally five or more, and the leakage current plotted. Good insulation to earth will show a linear plot (see Figure 1) whereas a non-linear plot (see Figure 2) would suggest an insulation weakness (or contamination) at that voltage. The DC step voltage test provides a great deal more information than the DC hipot test, and is therefore recommended for in- service motors.

It is argued that condition monitoring of electric motors should involve not only testing for such things as bearing failure (via vibration analysis, oil analysis and so forth) but also a structured testing regime for electrical faults and the monitoring of motor efficiency.

Energy costs are a major portion of any plant or facility’s operating expenditures and motors consume a very large part of those expenses.

Correct monitoring of motor performance, and making the necessary adjustments, will improve reliability, extend the life of the motor and reduce the overall operating cost of the facility.

Page 18: 4th Quarter Magazine downloadable

18 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Technical Feature

Figure 1 Linear leakage current plot

Figure 2 Non-linear leakage current plot

DC Hipot Test:The hipot test simply applies a voltage, measures leakage current and calculates meg-oms. If the meg- ohms are higher than the accepted minimum, the motor passes. Even if there is an area of damaged insulation, as long as the meg-ohms are higher than the minimum value, the motor will still pass.

Surge test:This final test is used to verify the turn to turn, coil to coil and phase to phase insulation condition and is typically performed at twice line voltage plus 1000 volts. It can detect weak insulation, dead shorts, loose connections, and unbalances caused by incorrect winding.

The surge test works by injecting high voltage pulses into each phase, creating a potential difference between one turn and the next. The resultant sine wave from each phase should match one another.

Paschen’s law states that in order to draw an arc between two conductors, a potential difference of at least 350 volts is required. When motors start and stop, high voltage spikes are generated, and these spikes are what damage the insulation over time, along with heat, attack from oil, ingestion of chemicals, and also movement of the copper wires due to the magnetic forces on start-up.Of all the tests described, the surge test is the only method of detecting weak turn insulation. Studies have shown that 80% of electrical failures originate as a turn to turn weakness, so in

order to detect such faults prior to motor failure, surge testing must be performed.

Figure 3 shows the result of a surge test on a 415 volt motor. The motor had been subjected to severe overheating, but still ran normally. A meg-ohm test at 500 volts passed with 1,438 meg- ohms.

The surge test failed at 1,590 volts on phase 1. Phases 2 and 3 both passed at the full test voltage of 2000 volts. All three waveforms should be balanced to each other.

Figure 4 shows the point at which phase 1 failed. The pulse to pulse graph plots all pulses that are injected into the three phases. The resultant graph should show close balance between the three phases. The red spike is the result of an arc within phase 1. When the arc took place, this caused the inductance of the phase winding to change momentarily, and we can also see this in

Figure 3, when the red waveform shifted to the left. Very early signs of turn to turn insulation weakness can be observed in the pulse to pulse graph, even though the surge waveforms may show close balance.

Figure 3 Failed surge test

Figure 4 Turn to turn arc detected

Why high voltage testing?A common question asked relates to the voltage levels that should be applied. Why should a 415 volt motor be subjected to a 2000 volt test ? The reason relates to the high voltage spikes that motors see on start-up and shut-down. 415 volt motors, particularly those started direct-on-line, will regularly see voltage spikes of up to 2000 volts. Therefore, to be able to ensure motor reliability, testing needs to be carried out at similar levels. International standards apply to all these tests, including IEC, IEEE, NEMA and EASA.

Page 19: 4th Quarter Magazine downloadable

19THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

Technical Feature

Dynamic Motor testingA more recent addition to electrical testing technologies is dynamic motor testing. Dynamic motor testing involves measuring the voltage and current of the motor’s three phases, whilst the motor is operating in its normal environment, and then calculating a host of information relating to the power supply, the motor, and the load. Both electrical and mechanical issues can be identified.

Power quality values, including voltage level, unbalance and distortion are determined and compared to industry standards. Poor power quality can lead to overheating within motors, and since heat is the biggest enemy of insulation, power issues should be identified & corrected where possible.

Current level and unbalance are used to determine overall electrical health, and are used to identify overloading, connection issues, iron saturation and incorrectly wound motors.

Spectrum analysis allows the condition of the rotor bars to be determined (see Fig 5) as well as showing the voltage and current relationship to frequency. Saturation problems, inverter issues as well as mechanical defects can be detected.

Torque can now also be used to find a host of issues including transient overloading, pump cavitation, mechanical imbalances and bearing faults among others.

Figure 5 Bad rotor bar graph

Figure 6 shows 28 seconds of instantaneous torque being demanded of a 2.2MW motor at a cement factory. With this application, one would not expect these large, rhythmical peaks of torque. These peaks highlighted a mechanical problem with the driven gear.

Transient analysis plots the rms voltage and current against time, whilst the motor is starting, and also plots the torque profile during that time. Monitoring all three phases of voltage and current, plus torque, allows maintenance engineers to separate power, motor and load issues.

Figure 7 shows the voltage and current plotted against time, during the start-up of a 132kw motor on a soft-start.

Figure 6 Torque ripple graph

Figure 7 Transient analysis

In summaryDynamic electrical testing can be used to identify a wide range of electrical and mechanical issues simply by measuring the 3 phase voltages and currents at the motor control cabinet. Dynamic testing can also be used to provide a comparison to other technologies, such of vibration analysis. It can be performed on submersible pumps and motors in restricted areas, simply by having access to the switch room.

For more information, please contact Engr. Mario Pilones, P.E.E. at Tel. no. 8104058 or email to [email protected]

Page 20: 4th Quarter Magazine downloadable
Page 21: 4th Quarter Magazine downloadable

©2013 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. • www.schneider-electric.com • 998-6064_GMA-GB

Discover how robust automation, control, and monitoring of energy usage can deliver up to 30% energy savings.Download our FREE Acti 9 brochure and get a chance to win an Indi-ya Solar Lamp! Visit www.SEreply.com Key Code 51941y

Put five generations of experience to work in your panelsWe leveraged five generations of low-voltage expertise to design a precise, high-quality modular system without compromise. Acti 9™ offers the fastest and most flexible installation experience, and completely eliminates safety concerns during maintenance and operation.

Acti 9 is high quality and engineered to adapt to the most challenging networks and environments while still remaining cost-effective over time. It is the most flexible, coordinated, comprehensive, and innovative range of low-voltage modular devices available.

Revolutionize communication in your installations In addition to the core protecting offer, the Acti 9 communication system uses Modbus protocol, provides real-time data from your panels and circuits. It allows load control and monitoring, and includes prefabricated wiring to give you instant, error-proof connectivity. Now you can monitor and control power on every floor, sector, office, and workshop.

The most flexible, coordinated low voltage system is now communication-ready

Acti 9 combines instant, error-proof connectivity to give you the safest, simplest, most efficient installations

Acti 9 Smartlink communication module

Control and monitoring

Protection devices Protection monitoring and supervision Installation systems

Ready to be connected Centralize control, collect energy meter data with just a simple communication module.

Safe and reliableReliable, error-proof manufacturer-guaranteed connections. EMC tested for immunity, radiated, and conducted safety.

Save 40% of your timeOne-click, prefabricated wiring for communication between your distribution panel and any facility management system.

IIEE_Magazine_Philippines_1202_51941y_PH.indd 1 11/28/13 2:29 PM

Page 22: 4th Quarter Magazine downloadable

22 THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

I. INTRODUCTION

In 1975, in an IEEE transaction entitled ‘General Expression for Positive Switching Impulse Strength Valid Up to Extra Long Air Gaps’, G. Gallet published a deterministic approach in the calculation of critical flashover (CFO) voltage that became the basis for clearance distances.

The North American Electric Reliability Corporation (NERC), with its aim to improve the reliability of the transmission systems, has used the ‘Gallet’s Method’ to define the minimum vegetation clearance distance (MVCD) to overhead power lines. The NERC FAC-003-2, entitled as ‘Transmission Vegetation Management Standard’, the NERC summarized the MVCD for various voltage levels and altitudes as shown in Table 1.

The technical paper shall detail how the MVCD values are calculated and shall provide example to further illustrate Gallet’s method.

Calculation of Minimum Vegetation Clearance Distance (MVCD) to Overhead Power Lines

Engrs. John C. Placente and Ronald Vincent M. Santiago

II. FORMULAE FOR GALLET’S METHOD

The following are the important formulae and values associated with Gallet’s Method and the calculation of MVCD:

1

85.0

34008

m

gwi

Vkk

D

D

kkCFO gwS 81

3400

6.8A

e

D

kkV mgwm 81

340085.0

2.0500500

25.1D

CFOD

CFOm sS

6 Maximum Transient Overvoltage at Distance D or

Withstand Voltage of the Air Gap

III. ALGORITHM

The following are the procedures in the calculation of minimum vegetation clearance distance (MVCD) using Gallet’s method:

1. Obtain the nominal system voltage and the altitude of the line.2. Determine the maximum system voltage.3. Compute for the Transient Peak Voltage.4. Compute for the Initial Clearance Distance.5. Compute for the Withstand Voltage of the Air Gap or the Maximum Transient Overvoltage at a distance.5.1. Compute for the Critical Flashover at standard atmospheric condition.5.2. Compute for the relative air density.5.3. Compute for the exponent, m.5.4. Compute for the withstand voltage of the air gap.6. If the withstand voltage of the air gap is less than the transient peak voltage, increase the value of D.7. Repeat Step 5 to 6 (iteration) until such time that the value of the withstand voltage of the air gap is slightly more than the transient peak voltage.

Technical Feature

Table 1. Minimum Vegetation Clearance Distance (MVCD)

The North American Electric Reliability Corporation (NERC) published FAC-003-2 entitled as ‘Transmission Vegetation Management Standard’. The purpose of the standard is to improve transmission systems’ reliability by preventing the outages caused by trees and other vegetation. It provides the minimum vegetation clearance distances (MVCD) to overhead power lines and the MVCD is being used on right-of-way/easement width determination, and also in vegetation clearing operations in overhead power lines. The MVCD is based on ‘Gallet’s Method’ which calculates for the critical flashover voltages and withstand voltage of air gap, thereafter determine the minimum clearance needed for an electric flashover to happen. The technical paper shall present the formulae associated with the Gallet Method and the algorithm for the calculation of MVCD. An example is also provided showing how the MVCD for a 230 kV transmission line is obtained.

No Description Formula / Values1 Transient

Overvoltage Factor, ftrOV

2 Transient Peak Voltage, VtrPK trOVtrPK f

VV

32max

above 365kVfor 1.4, below 240kVfor ,0.2

trOVf

3 Initial Clearance Distance, Di

kW = 1.037 (wet/outside)kg = 1.3 (gap)

4 Critical Flashover at Standard

Atmospheric Conditions, kV

5 Relative Air Density, where A = Altitude

in kmNominalSystemVoltage

(kV)

MaximumSystemVoltage

(kV)

Overhead Line Minimum Vegetation Clearance Distances(MVCD, meters) in Different Altitudes

SeaLevel 914m 1219m 1524m 1829m 2134m 2438m 2743m 3048m 3353m

765 800 2.36 2.71 2.8 2.88 2.97 3.05 3.14 3.22 3.31 3.39 500 550 1.54 1.73 1.79 1.85 1.91 1.98 2.04 2.11 2.17 2.24 345 362 0.95 1.08 1.12 1.16 1.21 1.26 1.3 1.35 1.4 1.44 230 242 0.91 1.02 1.06 1.11 1.15 1.19 1.24 1.29 1.33 1.38 161 169 0.61 0.69 0.73 0.76 0.79 0.82 0.85 0.89 0.92 0.96 138 145 0.52 0.59 0.62 0.65 0.67 0.7 0.73 0.76 0.79 0.82 115 121 0.43 0.49 0.51 0.53 0.56 0.58 0.61 0.63 0.66 0.69 88 100 0.35 0.4 0.42 0.44 0.46 0.48 0.5 0.52 0.54 0.57 69 72 0.25 0.29 0.3 0.31 0.33 0.34 0.36 0.37 0.39 0.41

Page 23: 4th Quarter Magazine downloadable

23THE ELECTRICAL ENGINEER MAGAZINE 4TH QUARTER 2013

IV. EXAMPLE

Example #1. Compute for the MVCD for a 230 kV line with an altitude of 2.134 km.

Step 1. Nominal system voltage = 230 kV, Altitude = 2.134 km.Step 2. Maximum system voltage for 230 kV = 242 kV.Step 3. Transient Peak Voltage = 395.18 kV

 

kV

kV

fVV trOVtrPK

18.395

0.23

224232max

=

××

=

××

=

230kVfor 0.2=trOVf

Step 4. Initial Clearance Distance = 0.9031 m

mD

Vkk

D

i

m

gwi

9031.0

1

85.018.395

3.1037.134008

1

85.0

34008

Step 5. Withstand voltage of the air gap = 303.1 kV. (For further iteration, not final)

Step 5.1. Critical Flashover at Standard Atmospheric Condition (CFOS) = 464.94 kV

kVCFO

D

kkCFO

S

gwS

94.4649031.081

34003.1037.1

81

3400

Step 5.2. Relative air density = 0.78

78.06.8134.2

6.8

e

eA

Step 5.3. Exponent m = 1.0678

0678.1

2.09031.050094.464

9031.050094.46425.1

2.0500500

25.1

D

CFOD

CFOm sS

Step 7. Repeat steps 5 to 6 until the obtained value of withstand voltage of the air gap exceeds near transient peak voltage.

No D CFO (kV)

m Vm Vm< VtrPK? Increment

0 0.9031 464.94 1.0678 303.10 YES 0.11 1.0031 510.69 1.0414 335.12 YES 0.12 1.1031 555.43 1.0159 366.80 YES 0.053 1.1531 577.43 1.0034 382.51 YES 0.024 1.1731 586.17 0.9985 388.77 YES 0.025 1.1931 594.86 0.9936 395.02 YES 0.0016 1.1941 595.30 0.9934 395.33 NO

Therefore, the MVCD is 1.1941 meters.

REFERENCES

1) G. Gallet, G. Leroy, R. Lacey, I. Kromer, General Expression for Positive Switching Impulse Strength Valid Up to Extra Long Air Gaps, IEEE Transactions on Power Apparatus and Systems, Vol. pAS-94, No. 6, Nov./Dec. 1975.

2) North American Electric Reliability Corporation. Transmission Vegetation Management NERC Standard FAC-003-2 Technical Reference, September 2009.

Step 5.4. Withstand voltage of the air gap = 303.1 kV.

kVV

D

kkV

m

mgwm

1.3039031.081

340078.03.1037.185.0

81

340085.0

0678.1

Step 6. Withstand voltage of the air gap is lesser than the transient peak voltage. Therefore, increase the value of D.

kVkVVV trPKm

18.3951.303

JOHN PLACENTE is a faculty member (Assistant Professor III) of the School of EECE and School of Graduate Studies of Mapua Institute of Technology. He is also a Consultant (Reliability and Special Studies) of the National Transmission Corporation (TransCo) and

an E&I Design Consultant of OTV France. He received his Bachelor of Science in Electrical Engineering (BSEE, Cum Laude) from Pamantasan ng Lungsod ng Maynila (PLM) in 2004 and his Master of Science in Electrical Engineering (MSEE, Cum Laude) from Mapua Institute of Technology (MIT) in 2009. Currently, he is pursuing his PhD Electronics Engineering in MIT. He is a Registered Electrical Engineer (REE, 15th Placer) and a Certified Instrumentation and Controls Engineer (CICE). He is a member of the Institute of Integrated Electrical Engineers of the Philippines (IIEE), Philippine Instrumentation and Controls Society (PICS) and the International Association of Engineers (IAENG).

RONALD VINCENT SANTIAGO is currently the Electrical Engineering Program Chairperson of the School of Electrical, Electronics and Computer Engineering (EECE) of Mapua Institute of Technology (MIT). He received his Bachelor of Science in Electrical Engineering (BSEE) from MIT in 1989 and

Master of Engineering in Electrical Engineering (MEEE, Magna Cum Laude) from MIT in 2000. He is a Registered Electrical Engineer (REE) and is the Academic Affairs Committee Chairman of the Institute of Integrated Electrical Engineers of the Philippines (IIEE). Engr. Santiago was awarded as the 2004 Outstanding Electrical Practitioner in the Field of Academe by the IIEE and by the Mapua Institute of Technology Electrical Engineering Alumni Association (MITEEAA). He is also the past president (2010-2011) of the MITEEAA, member of the Bureau of Product Standards Technical Committee 10 (TC10) of the Department of Trade and Industry (DTI), an accreditor/assessor for Philippine Association of Colleges and Universities Commission on Accreditation (PACUCOA) and Commission on Higher Education Regional Quality Assessment Team (CHED-RQAT).

Technical Feature

About the Authors

Page 24: 4th Quarter Magazine downloadable

Light up the future with the new SACE Emax 2. Not just a circuit-breaker, but a true power manager that controls every electrical system, raising the ef�ciency. SACE Emax 2 protects the system, manages loads and generators, measures and analyses energy quality. It is simply integrated into all projects - from standard systems to the most complex automated networks - all with the simplicity and reliability you would expect.Circuit-breakers switch power. SACE Emax 2 manages it. www.abb.com

ABB, Inc.Low Voltage ProductsKm. 20 west Service Road; Barangay Marcelo Green1700, Parañaque City, Metro Manila, PHILIPPINESPhone: +63 2 821 7777Telefax: +63 2 824 4637

SACE Emax 2. Managing the power.