11
Note for Guidance on Quality of Water for Pharmaceutical use
The European Agency for the Evaluation of Medical Products
Praphon Angtrakool
Food and Drug Administration
-
22
Introduction
Water may be present as
An excipient
Used for reconstitution of products
During systhesis
During production of the finished product
As a cleaning agent for rinsing vessels, equipment.
Primary packaging materials, etc.
-
33
Background (1)
A new Ph Eur. monograph entiled Highly Purified Water
has been adopted and will be implemented in the Ph Eur.
from 1st January 2002
WFI should be prepared only by distillation as laid down
in Ph Eur.
The CPMP/CVMP Quality Working Party and Inspections
Party have recently reconsidered the use of RO water for
preparation of WFI.
-
44
Background (2)
They have concluded on the available evidence, that the
production of water by RO and associated technologies
is considered to lack the robustness of distillation and
concerns remain about the potential risks associated
with, for examples, fouling of membrane (chemical and
biological), failure of membrane integrity and lack of
effective validation.
Hence the current view is that Highly Purified Water is
not acceptable for WFI.
-
55
Scope This document is intended to provide guidance to the
industry on the pharmaceutical use of difference grades of water in the manufacture of active pharmaceutical ingredients and medicinal products for human and veterinary use.
This guidance is not intended to cover situations where, for example
Medicinal products are prepared extemporaneously.
Where preparations are reconstituted/diluted with water prior touse by a pharmacist. (eg. Oral antibiotic mixtures)
In the case of veterinary products, by the user. (eg. Sheep drips)
-
66
Requirements of The European Pharmacopoeia
The European Pharmacopoeia provides standards for
the following grades of water
Water for Injections
Highly Purified Water
Purified Water
-
77
Potable Water
Potable Water is not covered by a pharmacopoeial
monograph but must comply with the regulations on water
laid down by the competent authority.
Potable water may be used in chemical synthesis and in
the early stages of cleaning pharmaceutical manufacturing
equipment unless there are specific technical or quality
requirements for higher grades of water.
-
88
Water for Injection
Water for Injection is water for the preparation of medicines
for parenteral administration when water is used as a
vehicle (water for injections in bulk) and for dissolving or
diluting substances or preparations for parenteral
administration before use. (sterilised water for injections)
Water for Injection complies with the tests for Purified
Water with additional for bacterial endotoxins (not more
than 0.25 IU of endotoxin per ml.), conductivity and Total
Organic Carbon.
-
99
Highly Purified Water Highly Purified Water intended for use in the preparation
of products where water of high biological quality is needed, except where Water for Injections is required.
Current production methods include, for example, double-pass reverse osmosis coupled with other suitable techniques such as ultra-filtration and de-ionization.
Highly Purified Water meets the same quality standards as WFI but the production methods are considered less reliable than distillation and thus it is considered unacceptable for use as WFI.
-
1010
Purified Water Purified water is water for preparation of medicinal
products other than those that require the use of water which is sterile and/or apyrogenic.
Purified water which satisfies the test for endotoxins may be used in the manufacture of dialysis solution.
Purified water is prepared by distillation, by reverse osmosis, by Ion exchange, by any other suitable method from water that complies with the regulation on water intended for human consumption laid down by the competent authority.
-
1111
European Pharmacopoeia (2005)Test WFI Highly Purified Purified
Total organic carbon NMT 0.5 mg/L NMT 0.5 mg/L NMT 0.5 mg/L
Conductivity (20 o C / 25 o C) 1.1 / 1.3 S-cm-1 1.1 / 1.3 S-cm-1 4.3 / 5.1 S-cm-1
Ammonium NMT 0.2 ppm --- ---
Aluminium --- NMT 10 ppb * NMT 10 ppb *
Ca and Mg Complies --- ---
Heavy metals NMT 0.1 ppm NMT 0.1 ppm NMT 0.1 ppm
Nitrates --- NMT 0.2 ppm NMT 0.2 ppm
Residue on evaporation Complies --- ---
Particulate contamination Complies --- ---
Total viable aerobic count 10 micro./ 100 ml. 10 micro./ 100 ml. 100 micro./ ml.
Sterility Complies --- ---
Bacterial endotoxin < 0.25 IU/ml < 0.25 IU/ml < 0.25 IU/ml *
* If intended for use in the manufacture of dialysis solution
-
1212
Quality of Water for Pharmaceutical Use
Validation and qualification of water purification, storage
and distribution systems are a fundamental part of GMP
and form an integral of the GMP inspection.
The grade of water used should take account of the
nature and intended used of the finished product and
the stage at which the water used.
-
1313
Water present as an excipient in the final formulation
WFI is required for those products intended for parenteral
administration and this includes for haemofiltration and
haemodiafiltration, and peritoneal dialysis.
For convenience the pharmaceutical industry often uses
WFI for the preparation of ophthalmic, sterile nasal/ear
and cutaneous preparation.
In such situation, Highly Purified Water represents a
useful alternative with the added advantage of satisfying
the industrys need for large volume.
-
1414
Sterile Medicinal Products
Sterile medicinal products Minimum acceptable quality of water
Parenteral WFI
Ophthalmic Purified
Haemofiltration SolutionsHaemodiafiltration Solutions
WFI
Peritoneal Dialysis Solutions WFI
Irrigation Solutions WFI
Nasal/Ear Preparations Purified
Cutaneous Preparation Purified
-
1515
Non-sterile Medicinal Products
Non-sterile medicinal products Minimum acceptable quality of water
Oral Preparations Purified
Nebuliser Solutions Purified *
Cutaneous Preparations Purified **
Nasal/Ear Preparations Purified
Rectal / Vaginal Preparations Purified
* In certain disease states eg. cystic fibrosis, medicinal products administered by nebulisation are required to be sterile and non-pyrogenic. In such cases WFI or sterilised Highly Purified Water should be used.
** For some products such as veterinary teat dips it may be acceptable to use potable water where justified and authorised taking account of the variability in chemical composition and microbiological quality.
-
1616
Water used during manufacture of APIs and medicinal products
Excluding water present as an excipient in the final
formulation.
The acceptable grade of water will depend heavily on
the stage at which it is to be used during manufacture,
the subsequent processing steps and the nature of the
final product.
-
1717
Water used during the manufacture of Active Pharmaceutical Ingredients (APIs) (1)
Type of manufacture
Product requirementsMinimum
acceptable quality of water
Synthesis of all intermediates of APIs prior to final isolation and purification steps
No requirement for sterility or apyrogenicity in API, or the pharmaceutical product in which it will be use
No requirement for sterility or apyrogenicity in API, or the pharmaceutical product in which it will be use
No requirement for sterility or apyrogenicity in API, or the pharmaceutical product in which it will be use
No requirement for sterility or apyrogenicity in API, or the pharmaceutical product in which it will be use
Potable water *
Fermentation media Potable water *
Extraction of herbal Potable water **
Final isolation and purification
Potable water *
-
1818
Water used during the manufacture of Active Pharmaceutical Ingredients (APIs) (2)
Type of manufacture Product requirementsMinimum
acceptable quality of water
Final isolation and purification
API is not sterile, but is intended for use in a sterile, non-parenteral productAPI is sterile and not intended for parenteral use
Final isolation and purification
API is not sterile, but is intended for use in a sterile, parenteral product
Purified Water with an endotoxin limit of 0.25EU/ml and control of specified organisms.
API is sterile and apyrogenic
Purified Water
Final isolation and purification
Purified Water
Final isolation and purification
Water For Injections
* Purified Water should be used where there are technical requirement for greater chemical purity.** The Application would need to demonstrate that potential variations in the water quality, particularly with
respect to mineral composition, would not influence the composition of the extract.
-
1919
Water used during manufacture of medicinal products
which is not present in the final formulation
Manufacture Minimum acceptable quality of water
Granulation Purified *
Tablet coating Purified
Used in formulation prior to non-sterile lyophilisation
Purified
Used in formulation prior to sterile lyophilisation
WFI
* For some veterinary premix products eg. granulated concentrates it may be acceptable
to use potable water where justified and authorised taking account of the API or used
as an excipient in a medicinal product.
-
2020
Water used for cleaning/rinsing of equipment,
containers and closures
In general, the final rinse used for equipment,
containers/closures should use the same quality of
water as used in the final stage of manufacture of the
API or used as an exipient in a medicinal product.
-
2121
Water used for cleaning/rinsing (1)
Cleaning/Rinsing of Equipment, Containers,
ClosuresProduct type Minimum Acceptable
quality of water
Initial rinse Intermidiates and API
API
Pharmaceutical products non-sterile
Pharmaceutical products non-sterile
Potable water
Final rinse Use same quality of water as used in the API manufacture
Initial rinse including CIP* of equipment, containers and closures, if applicable.
Potable water
Final rinse including CIP* of equipment, containers and closures, if applicable.
Purified Water or use same quality of water as used in manufacture of medicinal product, if highly quality than Purified Water
-
2222
Water used for cleaning/rinsing (2)
Cleaning/Rinsing of Equipment, Containers,
ClosuresProduct type
Minimum Acceptable quality of water
Initial rinse** including CIP* of equipment, containers and closures, if applicable.
Sterile products
Sterile non-parenteral products
Final rinse*** including CIP* of equipment, containers and closures, if applicable.
Sterile parenteral products
WFI ****
Purified Water
Final rinse*** including CIP* of equipment, containers and closures, if applicable.
Purified Water or use same quality of water as used in manufacture of medicinal product, if highly quality than Purified Water
-
2323
Water used for cleaning/rinsing (3)
* CIP = Clean In Place
** Some container, e.g. plastic containers for eyedrops may not
need an initial rinse, indeed this may be counter-productive since
particulates counts could be increased as a result. In some cases
e.g. blow-fill-seal processes rinsing cannot be applied.
*** If equipment is dried after rinsing with 70% alcohol, the alcohol
should be diluted in water of the same quality as the water used
for the final rinse.
**** Where a subsequent depyrogenisation step is employed the use
of Highly Purified Water may be acceptable subject to suitable
justification and validation data.
-
2424WHO Technical Report Series, No. 929, 2005
Annex 3WHO Good Manufacturing Practices : Water for pharmaceutical use
-
2525
6. Water purification, storage and distribution systems
6.2 Materials that come into contact with systems for water for pharmaceutical use
Suitable materials that may be considered for sanitary elements of the system include :
316 L (low carbon) stainless steel
Polypropylene (PP)
Polyvinylidenedifluoride (PVDF)
Perfluoroalkoxy (PFA)
Other materials such as materials such as un-plasticized polyvinylchloride (uPVC) may be used for non-hygienic designed water treatment equipment such as ion exchangers and softeners.
-
2626
6.5 Requirements for water distribution pipework (1)
6.5.3 Bio-contamination control techniques
The following control techniques may be used alone or more commonly in combination.
Maintenance of continuous turbulent flow circulation within water distribution systems reduces the propensity for the formation of biofilms.
The maintenance of the design velocity for a specific system should be proven during the system qualification and the maintenance of satisfactory performance should be monitored.
During the operation of a distribution system, short-term fluctuations in the flow velocity are unlikely to cause contamination problems provided that cessation of flow, flow reversal or pressure loss does not occur.
-
2727
6.5 Requirements for water distribution pipework (2)
6.5.3 Bio-contamination control techniques (cont.)
The system design should ensure the shortest possible
length of pipework.
For ambient temperature systems, pipework should be
isolated from adjacent hot pipes.
Deadlegs in the pipework installation greater than 1.5
times the branch diameter should be avoided.
-
2828
6.5 Requirements for water distribution pipework (3)
6.5.3 Bio-contamination control techniques (cont.)
Pressure gauges should be separated from the system by membranes.
Hygienic pattern diaphragm valves should be used.
Pipework should be laid to falls to allow drainage.
The growth of microorganisms can be inhibited by :
ultraviolet radiation sources in pipework;
maintaining the system heated (guidance temperature 7080 C);
-
2929
6.5 Requirements for water distribution pipework (4)
6.5.3 Bio-contamination control techniques (cont.)
The growth of microorganisms can be inhibited by : (cont.)
sterilizing or sanitizing the system periodically using superheated hot water or clean steam; and
routine chemical sanitization using ozone or other suitable chemical agents. When chemical sanitization is used, it is essential to prove that the agent has been removed prior to using the water. Ozone can be effectively removed by using ultraviolet radiation.
-
3030
Total viable aerobic count test for WFIEuropean Pharmacopoeia (2005)
During production and subsequent storage, appropriate measures are taken to ensure that the total viable aerobic count is adequately controlled and monitored.
Appropriate alert and action limits are set so as to detect adverse trends.
Under normal conditions, an appropriate action limit is a total viable aerobic count (2.6.12) of 10 micro-organisms per 100 ml. when determined by membrane filtration, using agar medium S, using at least 200 ml. of water for injections in bulk and incubating at 30 35 o C for 5 days.
For aseptic processing, stricter alert limits may need to be applied.
-
3131
Total viable aerobic count test for Purified WaterEuropean Pharmacopoeia (2005)
During production and subsequent storage, appropriate measures are taken to ensure that the total viable aerobic count is adequately controlled and monitored.
Appropriate alert and action limits are set so as to detect adverse trends.
Under normal conditions, an appropriate action limit is a total viable aerobic count (2.6.12) of 100 micro-organisms per milliliter, determined by membrane filtration, using agar medium S and incubating at 30 35 o C for 5 days.
The size of the sample is to be chosen in relation to the expected result.
-
3232
TOC test for Purified Water in BulkEuropean Pharmacopoeia (2005)
In addition, the test for total organic carbon (2.2.44)
with a limit of 0.5 mg./L or alternatively the following
test for oxidisable substances is carried out : to 100 ml.
add 10 ml. of dilute sulphuric acid R and 0.1 ml. of
0.02 M potassium permanganate and boil for 5 min;
the solution remains faintly pink.
-
3333
Total viable count test, USP 28 (2005)Methodologies that can be recommended as generally satisfactory for monitoring pharmaceutical water system are as follows :
Purified Water Pour Plate Method
Minimum sample 1.0 ml.
Plate count agar 48 to 72 hours incubation at 30 - 35 o C
Water for Injection Membrane Filtration Method
Minimum sample 100 ml.
Plate count agar 48 to 72 hours incubation at 30 - 35 o C
-
3434
Reference
1. European Pharmacopoeia 5.0, 2005
2. Note for Guidance on Quality of Water for Pharmaceutical use.
The European Agency for the Evaluation of Medical Products, 2002
3. The United State Pharmacopoeia 28, 2005
4. WHO Good Manufacturing Practices : water for pharmaceutical
use. In : WHO Expert Committee on Specification for
Pharmaceutical Preparations. Thirty-ninth report. Geneva, World
Health Organization, 2005, Annex 3 (WHO Technical Report
Series, No. 929)
Note for Guidance on Quality of Water for Pharmaceutical useIntroductionBackground (1)Background (2)ScopeRequirements of The European PharmacopoeiaPotable WaterWater for InjectionHighly Purified WaterPurified WaterEuropean Pharmacopoeia (2005)Quality of Water for Pharmaceutical UseWater present as an excipient in the final formulationSterile Medicinal ProductsNon-sterile Medicinal ProductsWater used during manufacture of APIs and medicinal productsWater used during the manufacture of Active Pharmaceutical Ingredients (APIs) (1)Water used during the manufacture of Active Pharmaceutical Ingredients (APIs) (2)Water used during manufacture of medicinal products which is not present in the final formulationWater used for cleaning/rinsing of equipment, containers and closuresWater used for cleaning/rinsing (1)Water used for cleaning/rinsing (2)Water used for cleaning/rinsing (3)6. Water purification, storage and distribution systems6.5 Requirements for water distribution pipework (1)6.5 Requirements for water distribution pipework (2)6.5 Requirements for water distribution pipework (3)6.5 Requirements for water distribution pipework (4)Total viable aerobic count test for WFIEuropean Pharmacopoeia (2005)Total viable aerobic count test for Purified WaterEuropean Pharmacopoeia (2005)TOC test for Purified Water in BulkEuropean Pharmacopoeia (2005)Total viable count test, USP 28 (2005)