4700 SERIES - Sterlco® – Steam Control Products...2017/10/10  · one pump opening covered when a...

5
Technical Specifications Sterlco ® 4700 Series Boiler Feed Units set new standards of performance. Reliable and efficient, each unit features heavy-duty cast iron receivers for long operating life. In addition, 3450 RPM motors assure maximum efficiency while maintaining minimum motor horsepower. Available in a wide range of sizes, these U.S. made units have just the right accessories and options to meet your unique needs. Standard Features • Heavy-duty cast iron receivers • Simplex or duplex construction • Stainless steel fitted centrifugal pumps • Energy efficient 3450 RPM motors • Automatic venting • Carbon ceramic pump seal (300°F) with EPDM elastomers • Heavy-duty make-up water valve • Gauge glass • Wide range of options and accessories Optional Features • Electric alternator for duplex units • Thermometer • Isolation valves • Solenoid operated make-up water valve with reverse acting float switch • Special motor construction, such as totally enclosed, washdown duty and explosion-proof is available • Elevated tanks are available • Complete NEMA 12 Control Panel Features Steam Traps | Condensate | Boiler Feed | Valves | Strainers | Pumps 2900 South 160 th Street, New Berlin, WI 53151 | P: 1.262.641.3808 E: [email protected] W: www.sterlco.com 4700 SERIES Boiler Feed Units - Cast Iron Tank

Transcript of 4700 SERIES - Sterlco® – Steam Control Products...2017/10/10  · one pump opening covered when a...

Page 1: 4700 SERIES - Sterlco® – Steam Control Products...2017/10/10  · one pump opening covered when a simplex design is specified. Operation: Boiler feed pump(s) are controlled by a

Technical Specifications Sterlco® 4700 Series Boiler Feed Units set new

standards of performance. Reliable and efficient, each

unit features heavy-duty cast iron receivers for long

operating life.

In addition, 3450 RPM motors assure maximum efficiency

while maintaining minimum motor horsepower. Available

in a wide range of sizes, these U.S. made units have just

the right accessories and options to meet your unique

needs.

Standard Features

• Heavy-duty cast iron receivers

• Simplex or duplex construction

• Stainless steel fitted centrifugal pumps

• Energy efficient 3450 RPM motors

• Automatic venting

• Carbon ceramic pump seal (300°F) with EPDM elastomers

• Heavy-duty make-up water valve

• Gauge glass

• Wide range of options and accessories

Optional Features

• Electric alternator for duplex units

• Thermometer

• Isolation valves

• Solenoid operated make-up water valve with reverse acting float switch

• Special motor construction, such as totally enclosed, washdown duty and explosion-proof is available

• Elevated tanks are available

• Complete NEMA 12 Control Panel

Features

Steam Traps | Condensate | Boiler Feed | Valves | Strainers | Pumps

2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.3808 E: [email protected] W: www.sterlco.com

4700 SERIESBoi ler Feed Units - Cast I ron Tank

Page 2: 4700 SERIES - Sterlco® – Steam Control Products...2017/10/10  · one pump opening covered when a simplex design is specified. Operation: Boiler feed pump(s) are controlled by a

Product Features

Unit:

Completely factory assembled

and tested. Simplex units have one

receiver, one make-up water valve,

and one vertical pump and motor

assembly. Duplex units have 2 vertical

pumps. All units are supplied with

a gauge glass on the side of the

receiver.

Motors:

Heavy-duty, ballbearing, close-

coupled pump motors with stainless

steel shaft. 3450 RPM for greater

efficiency and more economical

operation.

Make-up Water Valve:

Mechanical, plug mounted valve with

stainless steel float. Rated up to 45

psi inlet water pressure. (A pressure

reducing valve is required upon

installation.)

Receiver:

Heavy gauge steel construction. All

receivers of 45 gallon size and larger

are supplied in duplex design, with

one pump opening covered when a

simplex design is specified.

Operation:

Boiler feed pump(s) are controlled

by a water level controller mounted

on the boiler. If condensate is

lost or delayed in the system, it

is automatically replaced in the

receiver through the make-up water

valve.

Pump Seal (A):

Features the ultimate in ceramic

technology for exceptionally

long life. Seal is carbon ceramic

with EPDM elastomers. Rated for

temperatures up to 300°F.

Isolation Valve (B):

Optional on 4700 Series Boiler Feed

Units. Allows removal of pump

without draining the tank.

Elevated Unit

Control Panel

Complete NEMA 12 Control Panel (Optional)

• Motor Circuit Protector

• HOA Selector Switch

• External Reset

• Control Circuit Transformer

• Pilot Light (pump running)

• Removable Mounting Plate and Terminal Strip in a Single NEMA 12 Enclosure

• Mounted and Wired with Single Point Power Connection.

A

B

Inside view of control panel

2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.3808 E: [email protected] W: www.sterlco.com

4700 SERIES

Page 3: 4700 SERIES - Sterlco® – Steam Control Products...2017/10/10  · one pump opening covered when a simplex design is specified. Operation: Boiler feed pump(s) are controlled by a

4700 Series Engineering and Capacity Data

Sample Specification

Furnish and install, where indicated on plans, a Sterling 4700 Series (simplex or duplex) boiler feed unit(s). Each pump shall deliver __________

GPM at a discharge pressure of __________ PSI. The unit shall be factory assembled and tested by the pump manufacturer and shall include a

receiver, pump(s), make-up water valve, gauge glass, and accessories.

The receiver shall have a capacity of __________ gallons and be of heavy-duty cast iron construction. Pump(s) shall be of the centrifugal type

with one-piece enclosed stainless steel impeller, stainless steel inducer, cast iron housing, high temperature (300°F) mechanical seal and

stainless steel motor shaft. The make-up water valve is to be a mechanical, plug-type with a stainless steel float. An optional inlet “Y” or

basket strainer is recommended for installation on the tank return inlet for pump protection. The motor(s) shall be vertical, 3450 RPM,

__________ phase, __________ volt, 60 cycle, __________ H.P.

Specifications

Boiler HP

Discharge Pressure PSI

Pump Capacity,

GPM

MotorHP

Rec. Capacity, Gallons

Unit Model Number Shipping Weight, lbs.

Simplex Duplex Simplex Duplex

1520304050

31/23/41

1-1/236

4722-KF4732-KF4742-KF4752-KF

4722-KDF4732-KDF4742-KDF4752-KDF

465505510520

500580590600

30 20304050

61/23/41

1-1/236

4724-KF4734-KF4744-KF4754-KF

4724-KDF4734-KDF4744-KDF4754-KDF

465505510520

500580590600

45 20304050

91/23/4

1-1/21-1/2

50 4726-KF4736-KF4746-KF4756-KF

4726-KDF4736-KDF4746-KDF4756-KDF

575615620625

610690700710

60 20304050

121/23/4

1-1/21-1/2

504728-KF4738-KF4748-KF4758-KF

4728-KDF4738-KDF4748-KDF4758-KDF

575615620625

610690700710

75 20304050

151/21

1-1/22

75 47210-KF47310-KF47410-KF47510-KF

47210-KDF47310-KDF47410-KDF47510-KDF

785825830835

820900910920

100 20304050

201/21

1-1/22

12047215-KF47315-KF47415-KF47515-KF

47215-KDF47315-KDF47415-KDF47515-KDF

1043108510951100

1078116011801200

150 20304050

303/41

1-1/23

12047220-KF47320-KF47420-KF47520-KF

47220-KDF47320-KDF47420-KDF47520-KDF

1043108510951110

1078116011801220

2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.3808 E: [email protected] W: www.sterlco.com

4700 SERIES

Page 4: 4700 SERIES - Sterlco® – Steam Control Products...2017/10/10  · one pump opening covered when a simplex design is specified. Operation: Boiler feed pump(s) are controlled by a

Product Diagrams

2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.3808 E: [email protected] W: www.sterlco.com

4700 SERIES

H I

A

3.13

3/4" NPT MAKE UPWATER VALVE LOCATION75 GALLON RECEIVERONLY

F G E

D .13FOOT PAD

BACK VIEW

S NPTOVERFLOW

R NPTPROCESS RETURN

DRAIN

LIFTING EYES(OPTIONAL)

C

P

16.00

16.00

THERMOMETER(OPTIONAL)

CONTROL PANEL(OPTIONAL)

CAN BE MOUNTEDREMOTELY

ISOLATION VALVE(OPTIONAL)

3/4" NPT MAKE UPWATER VALVE LOCATION36, 50, AND 120 GALLON

RECEIVERS

GAUGE GLASS

GATE VALVE, CHECK VALVE,AND PRESSURE GAUGE

(OPTIONAL)

J

K

B

3.50

L

O N

M

Q NPT VENT

1-1/2" NPTPUMP

DISCHARGE

DUPLEX PUMP

BLANK OFF PLATE & GASKETREPLACES PUMP FORSIMPLEX UNITS

4700 "K" SERIES BOILER FEED UNITRECEIVER MATERIAL: CAST IRON

4700SER.K.BF.36-120

Page 5: 4700 SERIES - Sterlco® – Steam Control Products...2017/10/10  · one pump opening covered when a simplex design is specified. Operation: Boiler feed pump(s) are controlled by a

Product Diagrams

2900 South 160th Street, New Berlin, WI 53151 | P: 1.262.641.3808 E: [email protected] W: www.sterlco.comRev 10.10.2017

4700 SERIES

C

G H

M

4.58

2.00 TYP.

LIFTING EYES(OPTIONAL)

1/2" DIA. MOUNTINGHOLES (4) PLACES

MAKE UP WATER VALVELOCATION 75 GALLON RECEIVER ONLY

J

K

L

30.00

16.00

16.00

4.00 4.00

CONTROL PANEL(OPTIONAL)

CAN BE MOUNTEDREMOTELY

ISOLATION VALVE

GAUGE GLASS

3/4" NPT MAKE UPWATER VALVE

THERMOMETER(OPTIONAL)

DRAIN

A

B

D

I N NPT VENT

DUPLEX PUMP

GATE VALVE, CHECK VALVE,AND PRESSURE GAUGE

(OPTIONAL)

1-1/2" NPT PUMPDISCHARGE

D F

E

O NPTPROCESS RETURNP NPTOVERFLOW

4700 "K" SERIES ELEVATED BOILER FEED UNITRECEIVER MATERIAL: CAST IRON

4700SER.K.EBF.36-120

R.H SIDE VIEWSHOWN WITHOUT

OPTIONAL CONTROL PANEL