4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about...
-
Upload
doreen-neal -
Category
Documents
-
view
213 -
download
0
Transcript of 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about...
![Page 1: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/1.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
1
New ideas and old doubts about the calorimeter shaking procedure
Andrea VenturiINFN Pisa
![Page 2: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/2.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
2
Present status
• ECAL and HCAL cluster energies are changed according to the observed data vs MC discreapancies as a function of polar angle– qqbar events at Z peak
• polar angle from jet direction
– at a lower level w.r.t. EFLOW because of jet corrections
• PHCO for HCAL• PECO, PEST,ETDI,...for ECAL
– number of “raw” clusters is not changed
• it does not work if this is a relevant discreapancy
• Results (winter 01)– 4q: 9 MeV– electrons: 20 MeV– muons: 5 MeV– taus: 5 MeV
• The procedure has to be validate “a posteriori”– check “higher level” observables
before and after shaking: the changes should be of the level of the discrepancies
• angular bias• visible energy• ...
– understand the results• electron/muon difference: brems
corr ?
![Page 3: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/3.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
3
HCAL shaking
dataMC
data/MC
![Page 4: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/4.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
4
ECAL shaking
data/MC
dataMC
![Page 5: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/5.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
5
PHCO
Type 5(neut had)
Eflow
ETDI(towers)
PECO raw
PECOcorr.
Type 5(neut had)
Photons
Type 4(photons)
Eflow
Gampex
Corrections:leakageoverlapcracks
….
CoradocMC data
Platine
![Page 6: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/6.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
6
EFLOW energy: jet correction
dataMC
dataMC
![Page 7: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/7.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
7
Higher level observables and shaking
no shaking shaking
data MC (shaken)
black : MC (not shaken)blue : MC (shaken)
by Ann
![Page 8: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/8.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
8
ECAL is not easy
• ECAL is crucial and the present shaking is not that good:
• PECO raw vs PECO corrected– data vs MC discrepancies are
different– EFLOW (#5) uses PECO
corrected– EFLOW (#4) uses GAMPEX
• same correction as PECO corr. ?
– the shaking parameters are taken from PECO raw
– Why different discrepancies ?• it could be a useful tool to study
ECAL simulation discrepancies
– What should we use for the shaking ?
• should we use “shaking” ?
PECO corr: data/MC
PECO raw: data/MC
![Page 9: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/9.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
9
ECAL is not easy (II)
• Two different processes produce signal in ECAL
• e.m. interactions (photons, electrons)
• hadronic interactions (hadrons)
– data vs MC discrepancies can be very different
– Different shaking based on the particle id (identified photons/electrons) is not enough
• it does not take into account identification efficiency/purity
• it is not easy to propagate the shaking back to the “raw” banks
– cfr brems correction in lnqq
– Ideal: use of the MC history banks
• are they ok for ECAL ?
• Discrepancy is larger for type 4 and 5 separately than for the sum– shaking should “migrate” the
energy from photons to neutral hadrons and viceversa
• cfr. my test with modified ECAL noise banks
• study photon id algorithm to understand how to shake to change the algorithm performance
– shake each ECAL stack independently ?
• MC history banks ?
• Brems correction (enqq)– have specific studies ever been
done ?– check the effect of the shaking
![Page 10: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/10.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
10
std ENNO banknew ENNO bank
![Page 11: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/11.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
11
Photons: ad hoc corrections• Identified photon energies are
corrected with corrections (CORADOC) which are different between data and MC– how are they evaluated:
• pi0’s ?• di-muons radiative events ?• electrons ?• to be asked to MNM…(done!)
![Page 12: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/12.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
12
Photons (II)• Photons corrections are like jet
corrections:– they try to correct for the data
vs MC discrepancy– this has to be taken into account
in the shaking procedure• once the shaking has been
applied , new MC photon corrections have to be evaluated and used.
• not because photons are better !!
• But, are we sure about the present photon energy corrections:– do we need better correction or
tracking resolution problems ?
![Page 13: 4/04/2001Calorimeter shaking -Andrea Venturi - April '01 ALEPH week 1 New ideas and old doubts about the calorimeter shaking procedure Andrea Venturi INFN.](https://reader036.fdocuments.in/reader036/viewer/2022082818/56649efc5503460f94c0fc03/html5/thumbnails/13.jpg)
4/04/2001 Calorimeter shaking -Andrea Venturi - April '01 ALEPH week
13
Summary
• To be understood– PECO: raw vs corrected– noise banks and better
agreement: why ?
• Not to be forgotten– photon energy corrections are
not taken into account in shaking
• neither if they are correct: less discrepancy
• nor if they are not correct: additional discrepancy
• To be done– shaking-dependent photon
corrections– check observables after shaking
• e/mu present difference
• To be checked– have photon corrections to be
improved ?– simulation of the electron brems
(reconstruction)• who knows if it was studied in
the early days ?