400 Hz AVIATION CABLE SYSTEM - Prysmian Group

8
400 Hz AVIATION CABLE SYSTEM Moulded ground power cable with protective nose

Transcript of 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

Page 1: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

400 Hz AVIATION CABLE SYSTEMMoulded ground power cable with protective nose

Page 2: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

AIRCRAFT GROUND POWER400 Hz

Quick in-field

replacement of nose

Safety markings, grip

and seals

Lifetime extended

for moulded cable

Variety of plug

and nose options

QUICK IN-FIELD AND COST EFFECTIVE SYSTEM

Prysmian Group is proud to announce that we are now offering a 400 Hz moulded ground power supply cable system with a variety of assembly plug and nose options for airfield to ground terminal application.

Replacable assembly plugs and noses greatly extend the lifetime of 400 Hz moulded cables.

The solution is supplied with standard length of 28 meter of 400 Hz single jacket aviation cable and quick and easy field replacable assembly components. Special nose options (moulded or hard) extend the life time of moulded cables and protect against in-field wear and tear.

”Supplied with standard length of 28 meters of single jacket cable and replacable assemblies”

Page 3: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

CABLE SYSTEM

”Replacable assembly pieces extend the lifetime of 400 Hz moulded cables

and provide significant cost savings”

Page 4: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

400 Hz AVIATION CABLE - 1 kV MOBILE APPLICATION - 1 + 6 CORE SINGLE SHEATHED

Application400 Hz single sheath aviation cable designed

to be highly durable and versatile for all

purpose and weather applications. Outer

sheath is made of heavy duty reinforced

thermosest materials and is flame, oil and

ozone resistant. Suitable for indoors and out-

door application in severe flexing applications

where oil, chemicals and extreme tempera-

tures are considerations.

Technical data

Voltage:

> Rated voltage: 0,6/ 1 kV

> Test voltage: 3.500 V AC

> Ampacity: 260

Bending radius:

> Fixed installation: Min. 4 x D

> Flexible installation: Min. 6 x D

Tensile strength:

> Max.15 N/mm2

Temperature area

> Max. operating temperature: +90°C

> Min. operating temperature: -50°C

ConstructionDesign:

> 1 + 6 core

Conductor:

> Copper extra flexible

> Rope stranded acc. to class M

> Acc. to ASTM B-3 & 172, UL-62

Power insulation:

> Thermoset EPR

> Acc. to UL 1276

Neutral & control insulation:

> Thermoplastic PP

> Acc. to UL 1276

Outer sheath:

> Coextruded neopren

> Thermoset

> Black

Standard & approval> IEC 60502-1

> ETL listed to UL standard

Material property> Flame retardant: Yes

> Oil resistant: Yes> UV resistant: Yes

AIRCRAFT GROUND POWERCABLE

Page 5: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

Content is subject to changes acc. to current product development and or any changes to standards.

SINGLE JACKET

90°

Neutral conductor size AWG/mm2

Power conductor size AWG/mm2

Control conductor size AWG/mm2

Shielded controlconductor

1 x 1 AWG / 42,41 6 x 4 AWG / 21,15 16 x 18 AWG / 0,82 No

1 x 2/0 AWG / 67,44 6 x 2 AWG / 33,62 18 x 18 AWG / 0,82 Yes

Neutral conductor sizeAWG/mm2

Jacket thickness nom. mm

Cable outer diameternom.mm

Cable weight kg/km

1 x 1 AWG / 42,41 4,37 42,2 3347

1 x 2/0 AWG / 67,44 5,18 50,0 4990

Neutral conductor sizeAWG/mm2

Ampacity

1 x 1 AWG / 42,41 260

1 x 2/0 AWG / 67,44 300

Page 6: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

AIRCRAFT GROUND POWERCABLE NOSES

Application400 Hz single jacket aviation cable with

Integro molded plugs. The assembly is

intended for use in aircraft to ground

terminal applications.

The systems are supplied with standard length

of 28 meter of 400 Hz single jacket aviation

cable and quick and easy field replacable

assembly components. Other lengths are

also available upon request.

Special nose options (moulded or hard) extend

the life time of moulded cables and protect

against in-field wear and tear.

CABLE CONNECTING ASSEMBLYFOR 400 HZ MOULDED GROUND POWER SUPPLY CABLE

Page 7: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

SINGLE JACKET

Moulded nose> Molded in abrasion-resistant neoprene> Extends lifetime of molded cable plug> Field replaceable in minutes> E and F signal contact markings on side> Insertion marker for fully mated plug > Custom colors available

Hard nose > Include all benefits from moulded nose> Replaceable tip on nose > Highly density polymer > Abrasion resistant > Low coefficient of friction > Extended life time for molded nose > Reduces replacement costs> Field replacable in less than 60 seconds

Nose design > Spring design > Silver-plated copper > Maximum electrical conductivity> Double contacts points > Spring-loaded current bridges> Reduced overall contact resistance> Superior contact wiping > Rigid cylindrical receptacle > No damage from wear, tear or bending> No damage from heavy impacts

Moulded plug design> Abrasion resistant neoprene> Tapered interference seals > Watertight connection with nose> Molded grip rings for easy handling > Wear ribs for extend life time> Extended strain relief

> Marker for ease in mating nose and body

Page 8: 400 Hz AVIATION CABLE SYSTEM - Prysmian Group

Linking the future

Prysmian Group Denmark A/SRoskildevej 222620 AlbertslundDenmark

Sales +45 60 39 27 39 +45 60 39 26 29

[email protected]

Prysmian Group Finland OyKaapelitie 68, 02490 PikkalaJohdintie 5, 90620 OuluFinland

Sales +35 010 5661

[email protected]

Prysmian Group Sweden ABVallgatan 5, 57141 NässjöSweden

Sales+46 38 055 42 09 +46 38 055 42 08

[email protected] [email protected] [email protected] www.draka.se