4 Handed Dentistry

7
Transthorax Delivery The transthorax unit design meets the requirements of favorable time and motion and promotes favorable ergonomics. With the dental unit positioned over the patient’s thoracic area, the dental assistant can easily retrieve the handpieces and transfer them to the operator. This eliminates the shift of the operator’s vision away from the operating site. Repeated shifting of vision from a brightly illuminated operative field at close range to a darker area outside of the oral cavity located at a greater distance forces the eyes of the operator to accommodate for these. lighting and distance changes which can lead to eye fatigue and subsequent headache. A mobile cabinet with a moveable top that slides over the seated assistant’s knees serves as the primary source of supplies and instruments located well within the comfortable reach of the assistant. There are no hoses to interfere with the assistant’s position. This type of unit has been designed for the practice of the most effective four-handed dentistry. A fixed cabinet in the back enables the assistant to use a Class IV or V motion, if necessary, to obtain infrequently used items. Transthorax Pengiriman Transthorax The desain unit memenuhi persyaratan waktu yang menguntungkan dan gerak dan mempromosikan ergonomi yang menguntungkan. Dengan unit gigi berada di atas daerah dada pasien, asisten gigi dapat dengan mudah mengambil handpieces dan pemindahan mereka untuk operator. Ini menghilangkan pergeseran visi operator jauh dari lokasi operasi. Diulang pergeseran visi dari bidang operasi cerah diterangi jarak dekat ke daerah gelap di luar lisan

description

dentist

Transcript of 4 Handed Dentistry

Transthorax DeliveryThe transthoraxunit design meetsthe requirements offavorable time andmotion and promotesfavorable ergonomics.With the dental unitpositioned over thepatients thoracic area,the dental assistantcan easily retrieve thehandpieces and transferthem to the operator.This eliminates the shiftof the operators visionaway from the operating site. Repeated shiftingof vision from a brightly illuminated operative fieldat close range to a darker area outside of the oralcavity located at a greater distance forces theeyes of the operator to accommodate for these.lighting and distance changes which can leadto eye fatigue and subsequent headache. Amobile cabinet with a moveable top that slidesover the seated assistants knees serves asthe primary source of supplies and instrumentslocated well within the comfortable reach ofthe assistant. There are no hoses to interferewith the assistants position. This type of unithas been designed for the practice of the mosteffective four-handed dentistry. A fixed cabinet inthe back enables the assistant to use a Class IVor V motion, if necessary, to obtain infrequentlyused items.

Transthorax PengirimanTransthorax Thedesain unit memenuhipersyaratanwaktu yang menguntungkan dangerak dan mempromosikanergonomi yang menguntungkan.Dengan unit gigiberada di atasdaerah dada pasien,asisten gigidapat dengan mudah mengambilhandpieces dan pemindahanmereka untuk operator.Ini menghilangkan pergeseranvisi operatorjauh dari lokasi operasi. Diulang pergeseranvisi dari bidang operasi cerah diterangijarak dekat ke daerah gelap di luar lisanrongga berada pada jarak yang lebih besar memaksamata operator untuk mengakomodasi untuk ini.pencahayaan dan jarak perubahan yang dapat menyebabkankelelahan mata dan sakit kepala berikutnya. AKabinet ponsel dengan top bergerak yang slidelebih lutut asisten duduk menyajikan sebagaisumber utama pasokan dan instrumenterletak baik dalam jangkauan nyamanasisten. Tidak ada selang mengganggudengan posisi asisten. Jenis unittelah dirancang untuk praktek yang palingefektif empat tangan kedokteran gigi. Sebuah kabinet tetap dalambelakang memungkinkan asisten untuk menggunakan Kelas IVatau gerak V, jika perlu, untuk mendapatkan jarangitem yang digunakan.

Side DeliveryThis unit has been apopular concept formany decades. In fact,several dental schoolsuse this style of unitoften supplied with abracket tray since dentalstudents often have towork without a dentalassistant. Some units ofthis style even include acuspidor that interfereswith the assistantsposition and creates aninfection control problem as well as a physicalchallenge for a patient if they were to actuallyuse it. This style unit requires the dental operatorto retrieve and replace the handpieces which, inturn, forces the shift of vision from the treatmentsite, twists the upper body to turn to grasp thewanted instrument, and then refocus the eyesback on the operative field. This can resultin physical stress and eye fatigue. The sidedelivery style configuration prohibits the assistantfrom reaching the instruments to exchangehandpieces or change burs that requires moreunnecessary movement by the operator, thus,reducing productivity. Often in this arrangement,high velocity evacuation (HVE) is placed on theassistants side of the chair that, in turn, forcesthe assistant to be positioned too far away fromthe patient. At times, HVE hoses are locatedon the assistants mobile cabinet. The concernhere is whether the addition of the hoses to thiscabinet diminishes the cabinets effectiveness.The hoses may impede the function of a slidingtop or encroach on valuable storage space in the cabinet. As with the previous unit a fixed cabinetin the back enables the assistant to use a ClassIV or V motion, if necessary, to obtain infrequentlyused items.

Side PengirimanUnit ini telah menjadiKonsep populer untukbeberapa dekade. Faktanya,beberapa sekolah gigimenggunakan gaya ini unitsering disertakan denganbraket tray sejak gigisiswa sering harusbekerja tanpa gigiasisten. Beberapa unitGaya ini bahkan termasukcuspidor yang mengganggudengan asistenposisi dan menciptakanInfeksi masalah kontrol serta fisiktantangan bagi pasien jika mereka benar-benargunakan. Unit Gaya ini membutuhkan operator gigiuntuk mengambil dan mengganti handpieces yang, digilirannya, memaksa pergeseran visi dari pengobatanSitus, memelintir tubuh bagian atas untuk mengubah memahamiinstrumen yang diinginkan, dan kemudian kembali fokus matakembali di lapangan operasi. Hal ini dapat mengakibatkanstres fisik dan kelelahan mata. Sisikonfigurasi gaya penyampaian melarang asistenmencapai instrumen untuk bertukarhandpieces atau bur perubahan yang membutuhkan lebihGerakan yang tidak perlu oleh operator, dengan demikian,mengurangi produktivitas. Seringkali dalam pengaturan ini,kecepatan evakuasi tinggi (HVE) ditempatkan padaSisi asisten kursi yang, pada gilirannya, kekuatanasisten yang akan diposisikan terlalu jauh daripasien. Kadang-kadang, HVE selang beradadi kabinet mobile asisten. Perhatiandi sini adalah apakah penambahan selang untuk inikabinet mengurangi efektivitas kabinet.Selang dapat menghambat fungsi geseratas atau mengganggu pada ruang penyimpanan berharga dalam kabinet. Seperti dengan unit sebelumnya kabinet tetapdi belakang memungkinkan asisten untuk menggunakan KelasIV atau V gerak, jika perlu, untuk mendapatkan jarangitem yang digunakan.

Rear DeliveryThe operator is forcedto retrieve and replacethe handpieces withthis style of unit. Thisrequires extensivetwisting and turningas well as eye-strainas the operator isforced to turn from theoperating field to pickup a handpiece. Itis often necessary totransfer the handpiecefrom the retrieval handto the operating hand in order to use it. The unitsare mounted in a fixed position that cannot bemoved to accommodate for the changing workingpositions of the operator or for ease of use for theassistant. HVE hosing and air/water syringes arepermanently affixed to an assistants work area.Since it is in the rear, it requires the assistant tolean forward. When a mobile cabinet is used withthe rear delivery unit concept, it may interfere withaccess to the sink or to the HVE and air/watersyringe. For the assistant, this can provide unduestress and strain and limit access for increasedproductivity.Despite the ergonomic disadvantages, reardelivery units remain popular because they areattractive furnishings for the treatment room andhide the dental unit from the patients view.

Pengiriman belakangOperator dipaksauntuk mengambil dan menggantihandpieces denganGaya ini unit. Inimembutuhkan luasmemutar dan memutarserta mata-regangansebagai operator adalahdipaksa untuk beralih daribidang operasi untuk memilihup handpiece a. Saya Tsering diperlukan untukmentransfer handpiecedari tangan pengambilanke tangan operasi untuk menggunakannya. Unitdipasang dalam posisi tetap yang tidak dapatpindah ke mengakomodasi untuk kerja berubahposisi operator atau untuk kemudahan penggunaan untukasisten. HVE selang dan udara / air jarum suntik yangpermanen ditempelkan ke daerah kerja asisten itu.Karena di belakang, itu memerlukan asistenbersandar ke depan. Ketika kabinet mobile digunakan denganbelakang Unit pengiriman konsep, mungkin menggangguakses ke wastafel atau ke HVE dan udara / airjarum suntik. Untuk asisten, ini dapat memberikan semestinyastres dan ketegangan dan membatasi akses untuk meningkatkanproduktivitas.Meskipun kerugian ergonomis, rearunit pengiriman tetap populer karena merekaperabotan yang menarik untuk ruang perawatan danmenyembunyikan dental unit dari pandangan pasien.

Split Unit/CabinetThe split unit/cabinetconcept places partof the dental unit onthe operators sideand the HVE and air/water syringe on theassistants mobilecabinet. As in the sidedelivery unit, it requiresthe dentist to retrieve thehandpieces and makesthem inaccessible to the assistant, thus, reducing productivity. Theassistant can only use the HVE and the air/watersyringe that are attached to the mobile cabinetand is unable to transfer handpieces or changeburs for the operator. Often mobile cabinets usedin this concept are not designed to contain backupinstruments and adequate storage for dentalmaterials. The split unit design can limit theassistants working space and requires that backupinstruments be placed in tubs on the fixedcabinetry. This position requires additional motionto retrieve needed instruments and materials thatare stored in this manner and opens the door tocross contamination of instruments stored in thetubs. Again, a fixed cabinet in the back enablesthe assistant to use a Class IV or V motion, ifnecessary, to obtain infrequently used items.

Berpisah Unit / KabinetUnit perpecahan / lemaritempat konsep bagiandari unit gigi padasisi operatordan HVE dan udara /jarum suntik air padaponsel asistenkabinet. Seperti di sampingUnit pengiriman, membutuhkandokter gigi untuk mengambilhandpieces dan merekmereka tidak dapat diakses asisten, dengan demikian, mengurangi produktivitas. Ituasisten hanya dapat menggunakan HVE dan udara / airjarum suntik yang melekat pada kabinet selulerdan tidak dapat mentransfer handpieces atau perubahanburs bagi operator. Seringkali lemari selular yang digunakandalam konsep ini tidak dirancang untuk menampung cadanganinstrumen dan penyimpanan yang memadai untuk gigibahan bahan. Unit perpecahan desain dapat membatasiruang kerja asisten dan membutuhkan cadangan yanginstrumen ditempatkan di bak di tetaplemari. Posisi ini membutuhkan gerakan tambahanuntuk mengambil instrumen dan bahan yang dibutuhkan yangdisimpan dengan cara ini dan membuka pintu untukkontaminasi silang dari instrumen yang disimpan dalambak. Sekali lagi, kabinet tetap di belakang memungkinkanasisten untuk menggunakan Kelas IV atau gerak V, jikadiperlukan, untuk mendapatkan barang-barang yang jarang digunakan.

Instrument Grasps The pen grasp resembles the positioncommonly used to hold a pen or pencil andis widely used for most operative instruments(Figure 6). The modified pen grasp is similar to the pengrasp except the operator uses the pad of themiddle finger on the handle of the instrument.Some operators prefer this method since theyfeel it provides more strength and stability insome procedures. The palm grasp is used for bulky instruments.It is commonly used for surgical forceps, rubberdamp clamp forceps, straight chisels and the air/water syringe (Figure 7).The palm-thumb, or thumb-to-nose graspis used by the assistant for holding the oralevacuator. The operator may use this withinstruments that require a more verticalmovement (Figure 8).

Instrumen Merebut Pena pegang menyerupai posisibiasanya digunakan untuk memegang pena atau pensil danbanyak digunakan untuk sebagian besar instrumen operasi(Gambar 6). The pegang pena dimodifikasi mirip dengan penapegang kecuali operator menggunakan pad darijari tengah pada pegangan instrumen.Beberapa operator lebih memilih metode ini karena merekamerasa memberikan lebih banyak kekuatan dan stabilitas dibeberapa prosedur. The pegang sawit digunakan untuk instrumen besar.Hal ini biasanya digunakan untuk tang bedah, karettang penjepit basah, pahat lurus dan udara /jarum suntik air (Gambar 7).Telapak-ibu, atau ibu jari ke hidung pegangdigunakan oleh asisten untuk memegang mulutevacuator. Operator dapat menggunakan ini denganinstrumen yang memerlukan lebih vertikalGerakan (Gambar 8)