    3S 02 GATE

    ARCHITECTURE

    Presentation By

    Venu Gopal SE/AFC

  • 8/7/2019 3S 02 GATE architecture

    2/23

    CONTENTS

    INTRODUCTION

    BASIC MODULESOF 3S 02

    EXPLANATOINOF MODULES

    POWERFLOW

    DATAFLOW

    CASESTUDIES

    CONCLUSION

  • 8/7/2019 3S 02 GATE architecture

    3/23

    INTRODUCTION

    3S 02 GATEDESIGN

    ModularStructure

    Consists ofLRU s

    Ease of module replacement

    DESIGNADVANCEMENTSIN 3S 02

    OVERPREVIOUS MODELS

  • 8/7/2019 3S 02 GATE architecture

    4/23

    BASIC MODULES

    UCM

    PCM

    FLAPASSEMBLYSMA/SMV

    UPS

    SMPSDISPATCHERCARDS

    SENSORS

  • 8/7/2019 3S 02 GATE architecture

    5/23

    UCM

    Manages Gate overall operation

    Contains the Gate Operating

    SoftwareUCM is responsible for:-

    Initialization of Gate

    Mode Management

    Validation of media atSMV/SMA

    Authorization of passage after

    validating media

  • 8/7/2019 3S 02 GATE architecture

    6/23

    UCM communicates withSC

    UCM operates at 233 M Hz clock

    frequency

    DOM is of 64 MB

    DRAM- 32 MB extendible to 128 MB

    NVRAM- 512 KB

  • 8/7/2019 3S 02 GATE architecture

    7/23

    PCM

    PCM is responsible for passage

    managementwith authorization

    from UCM

    It monitors the passenger

    movementthrough 16 pairs of

    sensors

    Controls the movement of flaps

    Controls GED

  • 8/7/2019 3S 02 GATE architecture

    8/23

    FLAP ASSEMBLY

    Flap assembly consists of MIB,

    Motor,Solenoid,LimitSwitch,IPS,

    StopperBolt

    MIB interfaces all the external

    connectors to flap assembly

    Motor is ofDCtype operating at 48

    V DC

    Solenoid moves the flap

  • 8/7/2019 3S 02 GATE architecture

    9/23

    Limit switch indicates the latching

    of flap arm to solenoid

    IPS (Induction Proximity Switch)limits the movement of flap

    logically

    StopperBolt limits the movement

    of flap mechanically

  • 8/7/2019 3S 02 GATE architecture

    10/23

    SMA/SMV

    SMA/SMV are the media validating

    interfaces ofthe gate with

    passengersSMV is placed at entry side and

    validates bothCSC/CST

    SMA is placed at exit sidevalidating CSC/CST and capturing

    the CST

  • 8/7/2019 3S 02 GATE architecture

    11/23

  • 8/7/2019 3S 02 GATE architecture

    12/23

    SMPS

    It generates the DC power requiredby gate modules

    It uses switch mode technique for

    DC generationIt converts the 230 v AC output of

    Gate UPS into 24 V DC

    It feeds the 24 V DCto UCM andDispatcher cards which furtherfeeds SMA/SMV

  • 8/7/2019 3S 02 GATE architecture

    13/23

    DISPATCHER CARDS

    It is a DC-DC converter

    It converts 24 V DCto 12 V DC

    Located on both free and paid sidesFeeds 24 V to IOTACard and 12 V

    to CSCCard and PID

    It also acts as interface card forGate audio feeder channel

  • 8/7/2019 3S 02 GATE architecture

    14/23

    SENSORS

    There are sixteen pairs of opticalsensors located on each gate

    These sensors will track the

    passenger movementthroughtheisle

    16 sensors are divided into 4 zones

    Sensors defining the zone willchange depending on the thedirection of passage

  • 8/7/2019 3S 02 GATE architecture

    15/23

    POWERFLOW

    Operating Voltages Of Various

    Modules:-

    UCM 24 V DC

    PLC 48 V AC

    MOTOR 48 V DC

    SOLENOID 24 V DC

    SMA 24/12 V DC

    SMV 12 V DCPID 12 V DC

  • 8/7/2019 3S 02 GATE architecture

    16/23

    Gate will get 230 v AC as its input

    Itwill be taken through a MCB

    The output of MCBwill be given to

    Gate UPSthrough a spike

    suppressor

    Spike suppressor protects

    UPS/Gate against voltage spikes

    UPSwill give 230 V uninterruptedpowerto gate

  • 8/7/2019 3S 02 GATE architecture

    17/23

    UPS outputwill be given to a

    terminal block (TB-2)

    From TB-2 inputwill be given to

    SMPS and PLCtransformer

    SMPS converts 230 V AC into 24 VDC and feeds UCM,Free and Paid

    dispatchers

    Paid dispatcherwill give 24 V DCtoIOTA, and 12 V DCto PID

    IOTAwill give 12 V DCto CSC card

  • 8/7/2019 3S 02 GATE architecture

    18/23

    Free area dispatcherwill give 12 VDCto CSC card and PID

    PLCTransformerwill generate four

    differentAC voltages and feed PLC

    PLCwill convert inputAC into

    various DC voltages required for

    Motor,Solenoid and Sensors

  • 8/7/2019 3S 02 GATE architecture

    19/23

    DATA FLOW

    Presentation of media to SMA/SMV

    CSC reader reads it

    Authorization by UCMPID informs passenger

    Validation or errortone from LS

    If valid UCM gives command to PLCPLC operates the flap mechanism

  • 8/7/2019 3S 02 GATE architecture

    20/23

    Tracks the passenger movement

    with 16 pairs of sensors

    PLC closes the flaps immediately

    after passenger clears safety zone

    PLC sends passage completion toUCM

    UCM records the transaction and

    upload itto SC

  • 8/7/2019 3S 02 GATE architecture

    21/23

    CASE STUDIES

    Case Studies involving the

    modules

    UCM

    PLC

    SMA/SMV

    FLAPASSEMBLY

  • 8/7/2019 3S 02 GATE architecture

    22/23

    CONCLUSION

    Advantages of 3S 02 design

    Functional sub modules of 3S 02

    Gate

    Identification and functioning of

    various sub modules

    Power and Data Flow

    Precautions to be taken (through