3PAR Host Explorer 1.1.0 User’s Guide Pag1

28
3P AR Host Explorer 1.1.0 User’s Guide 3PAR Inc. 4209 Technology Drive Fremont, CA 94538 USA 320-200132 Rev A October 2009

Transcript of 3PAR Host Explorer 1.1.0 User’s Guide Pag1

  • 3PAR Host Explorer 1.1.0 Users Guide

    3PAR Inc.4209 Technology DriveFremont, CA 94538 USA

    320-200132 Rev A October 2009

  • Revision NoticeThis is the first release of this manual. A complete revision history is provided at the end of this document.

    ChangesThe material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, 3PAR Inc. assumes no liability resulting from errors or omissions in this document or from the use of the information contained herein.3PARdata reserves the right to make changes in the product design without reservation and without notification to its users.

    Updates to the Documentation at 3PAR CentralAny updates to this document, or to other 3PAR technical documents, can be found by logging on to 3PAR Centrals Document Control System from 3PARs Support page at http://www.3par.com/support/index.html

    3PAR Technical Support and ServicesContact your local service provider for technical support and services.

    Sales and Ordering InformationFor sales and ordering information, contact:3PAR Inc. 4209 Technology DriveFremont, CA 94538 USATelephone: 510-413-5999Fax: 510-413-5699Email: [email protected]

    Reader Comments and SuggestionsPlease email your comments and suggestions about this document to [email protected].

    Copyrights 2009 PAR Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of 3PAR Inc., 4209 Technology Drive, Fremont, CA 94538. By way of exception to the foregoing, the user may print one copy of electronic material for personal use only.

    Trademarks3PAR, InServ, InForm, InSpire and Serving Information are registered trademarks of 3PAR Inc.Microsoft, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation.UNIX is a registered trademark of The Open Group.All other trademarks and registered trademarks are owned by their respective owners.

    Federal Communications Commission Radio Frequency Interference StatementWARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment.

    This device complies with Part 15 of FFC Rules. Operation is subjected to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

    This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  • 3PAR Host Explorer Users Guide

    3.1 Overview 3.23.2 Installation and Verification 3.2

    3.2.1 Installing a 3PAR Host Explorer Agent on Microsoft Windows Server Systems 3.3

    3.2.2 Verifying the Installation on Microsoft Windows Server 3.3Table of Contents

    1 Introduction

    1.1 Overview 1.2

    1.2 Audience 1.2

    1.3 Related Documentation 1.3

    1.4 Organization 1.3

    1.5 Typographical Conventions 1.4

    1.6 Advisories 1.4

    2 Overview

    2.1 The 3PAR Host Explorer 2.1

    3 Installation and DeinstallationiiiTable of Contents

    3.2.3 Installing a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.3

    3.2.4 Verifying the Installation on Red Hat Linux Systems 3.4

    3.2.5 Installing a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.4

    3.2.6 Verifying the Installation on Solaris Sparc Systems 3.4

  • iv

    3PAR Host Explorer Users Guide3.3 Deinstallation 3.5

    3.3.1 Deinstalling a 3PAR Host Explorer Agent on Microsoft Windows Server 3.5

    3.3.2 Deinstalling a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.5

    3.3.3 Deinstalling a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.5

    4 Using the Host Explorer

    4.1 Overview 4.2

    4.2 Verifying the 3PAR Host Explorer Package is Installed 4.2

    4.3 Verifying the 3PAR Host Explorer Process is Running 4.2

    4.4 Stopping the 3PAR Host Explorer Process 4.2

    4.5 Starting the 3PAR Host Explorer Process 4.3

    4.6 Supporting Multiple InServ Storage Servers on a Single Host 4.3

    4.7 Supporting VMware Virtual Machines with iSCSI 4.3

    4.8 The 3PAR Host Explorer Enclosure Device LUN 4.3

    4.8.1 InServ Storage Server Upgrades and Enclosure Devices 4.4

    5 TpdHostAgent Command

    5.1 Overview 5.1

    5.2 TpdHostAgent Command 5.2

    RH Revision HistoryTable of Contents

  • 3PAR Host Explorer Users Guide1Introduction

    In this chapter

    1.2 Audience 1.2

    1.3 Related Documentation 1.3

    1.4 Organization 1.3

    1.5 Typographical Conventions 1.4

    1.6 Advisories 1.41.1Introduction

  • 1.2

    3PAR Host Explorer Users Guide1.1 OverviewThis guide provides information for installing and deinstalling a 3PAR Host Explorer on the

    following platforms:

    Microsoft Windows Server 2003 and 2008, 32 bit and 64 bit

    Red Hat Linux systems running RHEL4 Update 6 or later and RHEL5

    Sparc systems running Solaris 10

    Also, this guide provides reference information on the CLI utility TpdHostAgent, which allows management of the 3PAR Host Explorer on the hosts.

    1.2 AudienceThis guide is for Microsoft Windows, Red Hat Linux, and Solaris Sparc administrators who are

    responsible for maintaining the operating environment and who understand the InServ

    Storage Server.

    NOTE: For information about supported platforms refer to the 3PAR InForm OS

    2.3.1 Configuration Matrix, available from 3PARs Document Control System.Overview

  • 3PAR Host Explorer Users Guide1.3 Related DocumentationThe following documents also provide information related to InServ Storage Servers and the

    InForm Operating System:

    1.4 OrganizationThis guide is organized as follows:

    Chapter 1, Introduction (this chapter), provides an overview of this guide, including

    information on audience, related documentation, and typographical conventions.

    Chapter 2, Overview, provides an overview of the 3PAR Host Explorer program.

    Chapter 3, Installation and Deinstallation, describes how to install, verify, and uninstall the

    3PAR Host Explorer on Windows Server 2003 and 2008, Red Hat Linux, and Solaris Sparc

    operating systems.

    Chapter 4, Using the Host Explorer, describes procedures to stop, start and refresh the 3PAR

    Host Explorer.

    For information about Read the

    InServ Storage Server concepts and

    terminology

    3PAR InForm OS Concepts Guide

    Detailed CLI command descriptions and

    usage

    3PAR InForm Command Line Interface Reference

    Using the InForm Command Line Interface

    (CLI) to configure and administer InServ

    Storage Servers

    3PAR InForm OS CLI Administrators Manual

    Using the InForm Management Console to

    configure and administer InServ Storage

    Servers

    3PAR InForm OS Management Console Online Help1.3Related Documentation

  • 1.4

    3PAR Host Explorer Users Guide Chapter 5, TpdHostAgent Command, provides reference information for the

    TpdHostAgent command, a utility for management of the 3PAR Host Explorer on the host.

    This guide also contains a revision history describing the major changes for each version.

    1.5 Typographical ConventionsThis guide employs the following typographical conventions:

    1.6 AdvisoriesTo avoid injury to people or damage to data and equipment, be sure to observe the cautions

    and warnings in this guide.

    Typeface Meaning Example

    ABCDabcd Used for dialog elements

    such as titles, button labels,

    and other screen elements.

    When prompted, click Finish to

    complete the installation.

    ABCDabcd Used for paths, filenames, and screen output.

    Open the file

    \gui\windows\setup.exe

    Used for variables in filenames, paths, and

    screen output.

    Modify the content string by adding the -P option after -jar inform.jar

    NOTE: Notes are reminders, tips, or suggestions that supplement the procedures

    included in this guide.Typographical Conventions

  • 3PAR Host Explorer Users Guide

    creation and diagnosing host connectivity issues.When a host is created on the InServ Storage Server, unassigned WWNs or iSCSI names are

    presented to the storage server. Without the Host Explorers running on the attached hosts,

    the storage server is unable to determine which host the WWN or iSCSI names belongs to and

    you must manually assign each WWN or iSCSI name to a host. With Host Explorers running, the

    InServ Storage Server automatically groups WWNs or iSCSI names for the host together,

    assisting with creating the host.

    The Host Explorer collects the following information and sends it to the storage server:

    Host operating system and version.2Overview

    In this chapter

    2.1 The 3PAR Host Explorer 2.1

    2.1 The 3PAR Host ExplorerThe 3PAR Host Explorer is a program that runs on a host connected to an InServ Storage Server.

    The Host Explorer is an agent that runs as a service on Windows and as a daemon on Linux and

    Solaris operating systems. No license is required to use the 3PAR Host Explorer.

    The Host Explorer communicates with the storage server over an FC or iSCSI connection and

    enables the host to send detailed host configuration information to the storage server. The

    information gathered from the Host Explorer is visible for uncreated hosts and assists with host 2.1Overview

  • 2.2

    3PAR Host Explorer Users Guide Fibre Channel and iSCSI HBA details.

    Multipath driver and current multipath configuration.

    Cluster configuration information.

    Device and path Information.

    See Chapter 3, Installation and Deinstallation to install the 3PAR Host Explorer. Refer to the

    3PAR InForm OS 2.3.1 Configuration Matrix for a list of supported host operating systems.The 3PAR Host Explorer

  • 3PAR Host Explorer Users Guide

    3.3 Deinstallation 3.53.3.1 Deinstalling a 3PAR Host Explorer Agent on Microsoft Windows Server 3.5

    3.3.2 Deinstalling a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.5

    3.3.3 Deinstalling a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.53Installation and Deinstallation

    In this chapter

    3.1 Overview 3.2

    3.2 Installation and Verification 3.2

    3.2.1 Installing a 3PAR Host Explorer Agent on Microsoft Windows Server Systems 3.3

    3.2.2 Verifying the Installation on Microsoft Windows Server 3.3

    3.2.3 Installing a 3PAR Host Explorer Agent on Red Hat Linux Systems 3.3

    3.2.4 Verifying the Installation on Red Hat Linux Systems 3.4

    3.2.5 Installing a 3PAR Host Explorer Agent on Solaris Sparc Systems 3.4

    3.2.6 Verifying the Installation on Solaris Sparc Systems 3.43.1Installation and Deinstallation

  • 3.2

    3PAR Host Explorer Users Guide3.1 OverviewThis chapter describes how to install, verify, and deinstall the 3PAR Host Explorer agent on the

    following platforms:

    Microsoft Windows Server 2003 and 2008, 32 bit and 64 bit

    Red Hat Linux systems running RHEL4 Update 6 or later and RHEL5

    Sparc systems running Solaris 10

    3.2 Installation and VerificationThis section describes how to install and verify installation of a 3PAR Host Explorer agent. You

    must have the 3PAR Host Explorer CD, part number 780-200053 to install the 3PAR Host

    Explorer.

    NOTE: For information about supported platforms, refer to the InForm OS

    Configuration Matrix available from 3PARs Document Control System.

    NOTE: In order for the InServ Storage Server to dynamically discover host devices,

    you must follow specific configuration instructions for the host operating system

    and HBA. See the 3PAR Implementation Guides for recommended practices and

    detailed configuration information about using your specific host devices with

    the InServ Storage Server.

    NOTE: Each host connected to the InServ Storage Server must use a host persona

    with the SCSI Enclosure Services LUN (SESLun) enabled, or the Host Explorer agent

    cannot communicate with the InServ Storage Server. If you upgraded to 3PAR

    InForm Operating System version 2.3.1 from a previous release, you must convert

    your legacy personas to new host personas. For information about configuring

    host personas, see the 3PAR InForm OS CLI Administrators Manual or the 3PAR

    InForm OS Management Console Online Help.Overview

  • 3PAR Host Explorer Users Guide3.2.1 Installing a 3PAR Host Explorer Agent on Microsoft Windows Server Systems

    To install a 3PAR Host Explorer agent on a Microsoft Windows Server 2003 or 2008 system:

    1 Log into the host as the System Administrator.

    2 Insert the 3PAR Host Explorer CD into a CD-ROM drive.

    3 Open a Windows Explorer window.

    4 Select Start > All Programs > Accessories > Windows Explorer.

    5 Double-click the CD-ROM drive to expand the files.

    6 Double-click the appropriate file:

    For x86-32 platforms: HostExplorerX86.msi For x86-64-bit platforms: HostExplorerX64.msi

    3.2.2 Verifying the Installation on Microsoft Windows Server

    To verify the 3PAR Host Explorer agent installation for the Microsoft Windows Server 2003 or

    2008 system:

    1 Log on as the System Administrator.

    2 Select Start > Control Panel > Add/Remove Programs.

    Result: The Add/Remove Programs window appears.

    3 Verify 3PAR Host Explorer for Windows appears under the Currently installed

    programs column.

    3.2.3 Installing a 3PAR Host Explorer Agent on Red Hat Linux Systems

    To install a 3PAR Host Explorer agent on a Red Hat Linux system:

    1 Log on as the root user.

    2 Insert the 3PAR Host Explorer CD into a CD-ROM drive.

    3 Change directory to the CD-ROM drive.3.3Installation and Verification

  • 3.4

    3PAR Host Explorer Users Guide4 Issue the following command:

    3.2.4 Verifying the Installation on Red Hat Linux Systems

    Verify the 3PAR Host Explorer agent installation for the Red Hat Linux system:

    1 Log on as the System Administrator.

    2 Issue the following command:

    3.2.5 Installing a 3PAR Host Explorer Agent on Solaris Sparc Systems

    To install a 3PAR Host Explorer agent on a Solaris Sparc system:

    1 Log in as the root user.

    2 Insert the 3PAR Host Explorer CD into a CD-ROM drive.

    3 Change to the CD-ROM drive.

    4 Issue the following command:

    3.2.6 Verifying the Installation on Solaris Sparc Systems

    Verify the 3PAR Host Explorer agent installation for the Red Hat Linux system:

    1 Log on as the System Administrator.

    2 Issue the following command:

    # rpm -ivh HostExplorer-.i386.rpm

    rpm -qa | grep HostExplorer

    # pkgadd -d HostExplorer-sparc.pkg

    # pkginfo -l HostExplorerInstallation and Verification

  • 3PAR Host Explorer Users Guide3.3 DeinstallationThis section describes how to deinstall a 3PAR Host Explorer agent on:

    Microsoft Windows Server 2003 and 2008, 32 bit and 64 bit

    Red Hat Linux systems running RHEL4 Update 6 or later and RHEL5

    Sparc systems running Solaris 10

    3.3.1 Deinstalling a 3PAR Host Explorer Agent on Microsoft Windows Server

    To deinstall a 3PAR Host Explorer agent from a Microsoft Windows Server 2003 or 2008 system:

    1 Log on as the System Administrator.

    2 Select Start > Settings > Control Panel > Add/Remove Programs.

    Result: The Add/Remove Programs window appears.

    3 Select 3PAR Host Explorer for Windows.

    4 Click Remove.

    3.3.2 Deinstalling a 3PAR Host Explorer Agent on Red Hat Linux Systems

    To deinstall a 3PAR Host Explorer agent from a Red Hat Linux system:

    1 Log on as the root user.

    2 Issue the following command:

    3.3.3 Deinstalling a 3PAR Host Explorer Agent on Solaris Sparc Systems

    To deinstall a 3PAR Host Explorer agent from a Solaris Sparc system:

    1 Log on as the root user.

    2 Issue the following command:

    rpm -e HostExplorer-.i386.rpm

    pkgrm HostExplorer3.5Deinstallation

  • 3.6

    3PAR Host Explorer Users GuideDeinstallation

  • 3PAR Host Explorer Users Guide4Using the Host Explorer

    In this chapter

    4.1 Overview 4.2

    4.2 Verifying the 3PAR Host Explorer Package is Installed 4.2

    4.3 Verifying the 3PAR Host Explorer Process is Running 4.2

    4.4 Stopping the 3PAR Host Explorer Process 4.2

    4.5 Starting the 3PAR Host Explorer Process 4.3

    4.6 Supporting Multiple InServ Storage Servers on a Single Host 4.3

    4.7 Supporting VMware Virtual Machines with iSCSI 4.3

    4.8 The 3PAR Host Explorer Enclosure Device LUN 4.34.1Using the Host Explorer

  • 4.2

    3PAR Host Explorer Users Guide4.1 OverviewThe chapter provides instructions for using the 3PAR Host Explorer.

    4.2 Verifying the 3PAR Host Explorer Package is InstalledTo verify that the 3PAR Host Explorer package has been installed correctly, see the appropriate

    section below:

    To find out if the product is installed on a Solaris system, see Verifying the Installation on

    Solaris Sparc Systems on page 3.4.

    To find out if the product is installed on a Linux system, see Verifying the Installation on

    Red Hat Linux Systems on page 3.4.

    To find out if the product is installed on a Windows system, see: Verifying the Installation

    on Microsoft Windows Server on page 3.3.

    4.3 Verifying the 3PAR Host Explorer Process is RunningX To verify that the 3PAR Host Explorer process is running, issue the TpdHostAgent status

    command.

    Example output:

    4.4 Stopping the 3PAR Host Explorer ProcessBy default, the Host Explorer process starts at every reboot of the host.

    X If you do not want the process running on the host, issue the TpdHostAgent stop command.

    Printing the status of 3PAR Host Explorer daemon:3PAR Host Explorer is running..The current time interval values are:Value is PushInterval=86400 defaultValue is RefreshInterval=60 defaultOverview

  • 3PAR Host Explorer Users Guide4.5 Starting the 3PAR Host Explorer ProcessX To start the Host Explorer process, issue the TpdHostAgent start command.

    4.6 Supporting Multiple InServ Storage Servers on a Single HostThe 3PAR Host Explorer reports the information it collects to every InServ Storage Server

    attached to the host.

    If an InServ Storage Server is added or removed after the initial installation of the 3PAR Host

    Explorer, a refresh is needed.

    X To refresh the Host Explorer process, issue the TpdHostAgent refresh command.

    4.7 Supporting VMware Virtual Machines with iSCSIThe 3PAR Host Explorer supports VMware Virtual Machines connected to InServ Storage

    Servers with iSCSI connections. For information about supported Operating Systems on

    VMware Virtual Machines, refer to the InForm OS Configuration Matrix available from 3PARs

    Document Control System.

    4.8 The 3PAR Host Explorer Enclosure Device LUNWhen a host is connected to an InServ Storage Server, an enclosure device with LUN ID 254 is

    automatically defined for the host. The 3PAR Host Explorer uses this enclosure device to

    exchange information about the host with the InServ Storage Server. The LUN with ID 254 acts

    as both a data LUN and an enclosure service LUN. You can use LUN ID 254 for any application

    with limited impact on performance. The level of impact on performance depends on the

    application. The LUN with ID 254 is presented to the host even when no virtual volumes are

    exported to the host, or when the host is not configured on the InServ Storage Server.4.3Starting the 3PAR Host Explorer Process

  • 4.4

    3PAR Host Explorer Users Guide4.8.1 InServ Storage Server Upgrades and Enclosure Devices

    If you upgraded to 3PAR InForm Operating System version 2.3.1 from a previous release, you

    must consider the following notes about LUNs with ID 254.

    If you had a LUN with ID 254 before you upgraded to 2.3.1, the host persona for the host is

    set to the Generic-Legacy persona number 6 during the upgrade process. The port persona

    number must be reset to Generic persona number 1 before the Host Explorer can

    communicate with the InServ Storage Server.

    1) Use the InForm Command Line Interface (CLI) sethost persona 1 command to set the host persona number to 1.

    2) Use the controlport offline command to take the InServ Storage Server port the host is connected to offline.

    3) Use the controlport rst command to reset the InServ Storage Server port connected to the host.

    Alternatively, if you reboot the host after resetting the persona number as described in

    step 1, the Host Explorer automatically discovers the enclosure device on LUN ID 254 and

    sends the information to the InServ Storage Server. For more information about CLI

    commands, see the 3PAR InForm OS CLI Administrators Manual.

    If you add a host after you upgrade to 2.3.1, the host persona number for the host must be

    set to 1. For more information about creating and modifying hosts, see the 3PAR InForm OS

    CLI Administrators Manual.

    You can also use the InForm Management Console to configure and administer hosts

    connected to the InServ Storage Servers. For more information, see the 3PAR InForm OS

    Management Console Online Help.The 3PAR Host Explorer Enclosure Device LUN

  • 3PAR Host Explorer Users Guide5TpdHostAgent Command

    In this chapter

    5.1 Overview 5.1

    5.2 TpdHostAgent Command 5.2

    5.1 OverviewThe TpdHostAgent is a simple command line interface for maintaining and managing the

    various options to be used in conjuction with the Host Explorer daemon.

    This command must be run as superuser/administrator from the host where it is installed.5.1TpdHostAgent Command

  • 5.2

    3PAR Host Explorer Users Guide5.2 TpdHostAgent Command

    COMMAND

    TpdHostAgent

    DESCRIPTION

    Command line utility for management of a 3PAR Host Explorer.

    SYNTAX

    TpdHostAgent [options]

    OPTIONS

    -startStarts the Host Explorer process.

    -stopStops the Host Explorer process.

    -refreshStops, then restarts the Host Explorer process.

    -statusLists the status of a Host Explorer process, i.e. whether the daemon/service is

    running.

    -listLists the contents of all host configuration information (Host Explorer tokens) that

    has been gathered by the Host Explorer.

    -pushImmediately sends the latest Host Explorer token information to the InServ Storage

    Server.

    -set |Changes the default time intervals (RefreshInterval = 60 seconds, PushInterval = 86,400 seconds) used by the daemon to send token information to the InServ

    Storage Server.TpdHostAgent Command

  • 3PAR Host Explorer Users Guide RefreshInterval - The interval that the Host Explorer process collects the data and

    compares it to the last known state for any changes. If there are changes, the Host

    Explorer pushes the new set of data to the InServ Storage Server.

    PushInterval - The interval that the Host Explorer process pushes data to InServ

    Storage Server.

    -settrace This option is only available on the Windows operating system.

    1 - Displays error messages. 2 - Display warning messages and all messages below this level. 3 - Displays information messages and all messages below this level. 4 - Displays verbose messages and all messages below this level. 5 - Displays debug messages and all messages below this level.

    SPECIFIERS

    None.

    RESTRICTIONS

    None.

    EXAMPLES

    Starting the Host Explorer deamon.

    # TpdHostAgent startStarting the 3PAR Host Explorer daemon ..Starting 3PAR Host Explorer: [ OK ]5.3TpdHostAgent Command

  • 5.4

    3PAR Host Explorer Users GuideChecking the status of the Host Explorer deamon.

    # TpdHostAgent statusPrinting the status of 3PAR Host Explorer daemon:3PAR Host Explorer is running ...

    The current time interval values are:Value is PushInterval=86400Value is RefreshInterval=60

    Stopping the Host Explorer deamon.

    # TpdHostAgent stopStopping the 3PAR Host Explorer daemon..Stopping 3PAR Host Explorer: [ OK ]

    Sending the latest Host Explorer token information to the InServ Storage Server

    # TpdHostAgent pushSending the token information immediately

    Listing the contents of all host configuration information (Host Explorer tokens) gathered by

    the Host Explorer.

    # TpdHostAgent list

    Listing the Token information.-------------------------------

    TPDAGENTVER=1.1.0-14HNAME=192.168.45.14HOSTID=a8c00e2dOS=LinuxOSVER=2.6OSPATCH=9-22.ELsmpARCH=i686IP=192.168.45.14MPSW=device-mapperMPSWVER=1.01.04-1.0.RHEL4HBA0WWN=210000e08b0786bd ...TpdHostAgent Command

  • 3PAR Host Explorer Users Guide... HBA0VEN=QLogicHBA0MODEL=QLA2342HBA0DRVRVER=8.01.00b5-rh2HBA0FIRMWARE=3.03.15 IPXHBA1WWN=210100e08b2786bdHBA1VEN=QLogicHBA1MODEL=QLA2342HBA1DRVRVER=8.01.00b5-rh2HBA1FIRMWARE=3.03.15 IPXDEVICE0WWN=50002ac0000900c4DEVICE0NAME=350002ac0000900c4DEVICE0IOPOLICY=round-robinDEVICE0FPMPOLICY=turDEVICE0TOTPATHCNT=2DEVICE0GDPATHCNT=2DEVICE0PATH0HWWN=210000e08b0786bdDEVICE0PATH0TWWN0=21510002ac0000c4DEVICE0PATH0TWWN0STATE=OKDEVICE0PATH0TWWN1=20510002ac0000c4DEVICE0PATH0TWWN1STATE=OKDEVICE1IOPOLICY=round-robinDEVICE1FPMPOLICY=turDEVICE1TOTPATHCNT=2DEVICE1GDPATHCNT=2DEVICE1PATH0HWWN=210000e08b0786bdDEVICE1PATH0TWWN0=21510002ac0000c4DEVICE1PATH0TWWN0STATE=OKDEVICE1PATH0TWWN1=20510002ac0000c4DEVICE1PATH0TWWN1STATE=OK5.5TpdHostAgent Command

  • 5.6

    3PAR Host Explorer Users GuideTpdHostAgent Command

  • 3PAR Host Explorer Users Guide

    Revision History

    Release level Revision summary

    320-200132 Rev A

    October 2009

    First release of this manual.RH.1Revision History

  • RH.2

    3PAR Host Explorer Users Guide

    3PAR Host Explorer 1.1.0 Users GuideTable of ContentsIntroduction1.1 Overview1.2 Audience1.3 Related Documentation1.4 Organization1.5 Typographical Conventions1.6 Advisories

    Overview2.1 The 3PAR Host Explorer

    Installation and Deinstallation3.1 Overview3.2 Installation and Verification3.2.1 Installing a 3PAR Host Explorer Agent on Microsoft Windows Server Systems3.2.2 Verifying the Installation on Microsoft Windows Server3.2.3 Installing a 3PAR Host Explorer Agent on Red Hat Linux Systems3.2.4 Verifying the Installation on Red Hat Linux Systems3.2.5 Installing a 3PAR Host Explorer Agent on Solaris Sparc Systems3.2.6 Verifying the Installation on Solaris Sparc Systems

    3.3 Deinstallation3.3.1 Deinstalling a 3PAR Host Explorer Agent on Microsoft Windows Server3.3.2 Deinstalling a 3PAR Host Explorer Agent on Red Hat Linux Systems3.3.3 Deinstalling a 3PAR Host Explorer Agent on Solaris Sparc Systems

    Using the Host Explorer4.1 Overview4.2 Verifying the 3PAR Host Explorer Package is Installed4.3 Verifying the 3PAR Host Explorer Process is Running4.4 Stopping the 3PAR Host Explorer Process4.5 Starting the 3PAR Host Explorer Process4.6 Supporting Multiple InServ Storage Servers on a Single Host4.7 Supporting VMware Virtual Machines with iSCSI4.8 The 3PAR Host Explorer Enclosure Device LUN4.8.1 InServ Storage Server Upgrades and Enclosure Devices

    TpdHostAgent Command5.1 Overview5.2 TpdHostAgent Command

    Revision History