360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from...

9
360Sense with Tank Monitoring Sensor Installation Guide 360Tanks.com Mar 2018

Transcript of 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from...

Page 1: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense with Tank Monitoring Sensor

Installation Guide

360Tanks.com Mar 2018

Page 2: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

Support If at any time during your installation you need help, please contact: [email protected]

Box Contents

Installation Tools Required 1. Ladder 2. 50mm / 2 inch Hole Saw 3. Cordless drill 4. Outdoor silicone sealant 5. Spirit Level 6. Phillips head screwdriver

Safety

● Do not open the enclosure when on top of the tank. Ensure you are on the ground. ● The sensor contains internal batteries. Do not open the unit enclosure unless the area is

known to be free of ignitable concentrations. ● Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry.

ESD damage occurs when electronic components are improperly handled and can result in complete or intermittent failures.

● The sensor is intended for fixed installation, where the installation is intended to minimize the risk from ESD.

www.360Tanks.com 360Sense Tank Monitoring Sensor Installation Guide Mar 20182 / 9

Page 3: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

Installation Steps Make sure you are on the ground and in a safe environment when opening the enclosure unit. Do not open the unit when on top of the tank.

1

Unscrew the outer enclosure fastening screws and open the outer enclosure. Make a note of the IMEI number of the sensor you are installing. This can be found on the sensor label.

The IMEI is found on the sensor label and uniquely identifies the sensor. You can name your sensor in the 360

Tanks application. The IMEI identifier of each unit is also shown in the application settings for each sensor.

2

Open the sensor unit enclosure and plug in the battery to the black battery terminal on the board as shown. Then close the both the inner and outer enclosures.

The LED lights on the unit will start flashing every time the unit takes a reading. Once the battery is connected, this will occur automatically on the sensor reading interval or if you manually swipe with the magnet.

www.360Tanks.com 360Sense Tank Monitoring Sensor Installation Guide Mar 20183 / 9

Page 4: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

3

Locate and mark suitable position on the tank for the sensor noting the following conditions:

1. The sensor must be mounted horizontally, not at an angle on pitched roof tanks

2. Then sensor must be mounted away from the water inlet

3. Sensor to the maximum liquid level distance must be greater than 300mm for medium range or 100mm for short range sensors. Maximum liquid level is generally the bottom of the overflow outlet height.

4. Sensor horizontal distance to the tank wall must be greater than 500mm

5. On corrugated roofs, mount on the top of the corrugation, not in the channel

6. Drill a 50mm hole at the marked location For your safety, stay on the ladder. Tank manufacturers do not recommend climbing on the tank roof.

4 If the sensor is not already attached to the mount cradle, then assemble the sensor and cradle by:

1. Fix the sensor to the mount by inserting the sensor into the mount hole.

2. Secure the sensor to the cradle by screwing the threaded mount adapter onto the sensor.

www.360Tanks.com 360Sense Tank Monitoring Sensor Installation Guide Mar 20184 / 9

Page 5: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

5 Screw on the antenna.

Ensure the antenna is vertical after it is attached.

6

Install the assembled sensor and mount onto the tank.

1. Position the mounted sensor over the hole.

2. On pitched roofs, ensure the sensor is horizontal. To do this, loosen the mount wing nuts, adjust the angle of the sensor cradle then re-tighten the nuts. You may also need to swivel the base of the sensor to ensure the cradle is rotating up the slope, not sideways to the slope

www.360Tanks.com 360Sense Tank Monitoring Sensor Installation Guide Mar 20185 / 9

Page 6: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

7 1. Secure the mount to the tank with the 4 screws. Screw into the mount channel

2. Run a bead of silicone sealant around the threaded adapter in the 50mm hole to seal it.

8

Measure and record the 1. Sensor to Overflow distance in mm 2. Overflow to Base distance in mm

9

Activate your sensors through the 360 Tanks application.

1. Sign in to 360Tanks.com 2. Select the Status chart (the chart shows a

Pending sensor) 3. Find the Pending activation sensor that

matches the IMEI number of the unit you have installed.

4. Select

5. Follow the configuration screens entering in the tank installation measurements you took earlier.

www.360Tanks.com 360Sense Tank Monitoring Sensor Installation Guide Mar 20186 / 9

Page 7: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

6. Once the configuration screens are complete, your sensor view will now show ‘Waiting for first time connection’.

You can sign in and configure with your phone while still onsite. You can also update the configuration and

measurement settings at any time.

10

1. Bluetooth 2. Sensor Reading 3. Cellular and GPS 4. Battery

Wake up the unit and force it to take and upload an immediate measurement by tapping the magnet once next to the internal enclosure magnet sticker. The unit will wake up, the LED lights will flash, your first measurement will be taken and uploaded.

Check your tank level measurement on the monitoring application. If you need to adjust the configuration measurements you can anytime through the application by selecting the

sensor from the sensor page (select its name) then select Edit.

LED Light Guide Item LED Description

1 Bluetooth Indicator light for Bluetooth communication: ● Yellow blinking: Bluetooth is on and sensor is discoverable

2 Sensor reading

Indicator light for the sensor(s): ● Green blinking: One or more sensors are reading the environment

www.360Tanks.com 360Sense Tank Monitoring Sensor Installation Guide Mar 20187 / 9

Page 8: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

3 Cellular Indicator light for the cellular network connection: ● Solid purple: Sensor is waking ● Red blinking: Searching for the cellular network ● Blue:

○ Blinking: Connected to the cellular network and attempting to communicate with online services

○ Solid light: Successfully sent data to online service; turns off after a few seconds

4 Battery Indicator light for battery function: ● Solid purple: Connect Sensor is waking ● Red blinking: Indicates battery life is less than or equal to the

Battery Life alarm ● Blue blinking: Indicates battery life is greater than the Battery Life

alarm

Installation FAQs Please check our online Frequently Asked Questions regarding installations. Find these at www.360tanks.com then select to FAQ at the top of the page. If your question is not answered here please contact us at: [email protected]

Limited Warranty Upon Your payment in full of Your Sensors Purchase Price and Our delivery to You of Your Sensors, we warrant to You that for a period of the earlier of: (a) three years following the delivery of Your Sensors to You; or (b) the expiration or termination of Your Subscription to the 360Tanks Service (the “Limited Warranty Period”), Your Sensors will operate in accordance with the written specifications for the Sensors (the “Sensor Specifications”) located at www.360tanks.com (the “Limited Warranty”). The Limited Warranty does not apply in the event that any part of Your Sensors (including any of Our Software therein) have been: (i) used other than in accordance with these T&Cs, the Sensor Specifications or other written operating instructions provided by Us or Our agents to You; (ii) modified, repaired, serviced, maintained or altered by anyone other than Us or one of Our authorized agents without Our prior written approval in each instance; (iii) combined with or installed on/with operating systems, hardware or other equipment that do not constitute Our Hardware or Our Software; (iv) used or installed not in accordance with the Sensor Specifications; (v) damaged by causes beyond the Our reasonable control; or (vi) sold or transferred to any Person other than You. The Limited Warranty extends only to You and does not extend to any other Person. EXCEPT FOR THE LIMITED WARRANTY, YOUR SENSORS ARE PROVIDED ON AN “AS IS” BASIS WITHOUT ANY WARRANTY OR CONDITION WHATSOEVER, AND WE

www.360Tanks.com 360Sense Tank Monitoring Sensor Installation Guide Mar 20188 / 9

Page 9: 360Sense with Tank Monitoring Sensor · 2018. 4. 15. · 2. Then sensor must be mounted away from the water inlet 3. Sensor to the maximum liquid level distance must be greater than

360Sense Tank Monitoring Sensor Installation Guide

EXPRESSLY DISCLAIM ALL OTHER IMPLIED OR STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, TITLE, NON-INFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE. WE DO NOT WARRANT THAT YOUR SENSORS WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION OF YOUR SENSORS WILL BE UNINTERRUPTED OR ERROR-FREE.