Freedom during your x-ray examination - the powerful battery unit The TRB90/20V battery unit is the ideal companion for the use in remote areas or when working with horses on the field. No disturbing cables, but instead of that the comfortable handling and the possibility to do up to approx. 300 exposures with one battery charge. For further information call 1300 785 401 - Northern Office 1300 785 405 - Southern Office Email: [email protected] www.dlcimaging.com.au Atomscope Tough Ray TRB90/20V

description

 

Transcript of 330014 Atomscope TRB9020V battery x ray unit

Freedom during your x-ray examination - the powerful battery unit

The TRB90/20V battery unit is the ideal companion for the use in remote areas or when working with horses on the field. No disturbing cables, but instead of that the comfortable handling and the possibility to do up to approx. 300 exposures with one battery charge.

For further information call 1300 785 401 - Northern Office 1300 785 405 - Southern Office

Email: [email protected]

Atomscope Tough Ray TRB90/20V

Atomscope Tough Ray TRB90/20V Suitable for Equine use.

Southern Office: Ph: 03 9360 9700 · Fax: 03 9360 9444 · Toll Free: 1300 785 405 · Email: [email protected] PO Box 4438, 17-19 Horne Street, Hoppers Crossing, VIC, 3029Northern Office: Ph: 07 5428 3666 · Fax: 07 5428 3777 · Toll Free: 1300 785 401 · Email: [email protected] PO Box 833, Unit 6/1 Lear-Jet Drive, Caboolture, QLD, 4510

www.dlc.com.au · www.dlcimaging.com.au

Specifications:

» Battery operated high frequency X-ray unit

» Weighing only 6.8 kg (battery included)

» Up to approx. 300 exposures with one battery charge

» Operator friendly and centrally balanced

» Charging time approximately 240 minutes

» Serial interface for connection with digital radiography systems

» Collimator with scale to adjust the size of the light – radiation field

» Collimator light can be activated via the hand switch

» Display for battery status

» Acoustic and optical timer signal

» 5 memory buttons

» Dual laser pointer

» Digital display „X-RAY“, „READY“ and „ERROR“

» Tape measure for film – focal spot distance

» Aluminum casing

» Robust and solid design

Charger

Inverter Frequency: 100 kHzPower Requirement: 1,35 kVAOutput in 2-kV Steps: 40 – 60 kV = 20 mA (max.) 62 – 80 kV = 15 mA (max.) 82 – 90 kV = 10 mA (max.) 82 – 90 kV = 15 mA (max. high power mode)X-ray tube: Toshiba D - 0814Focal spot: 0,8 mm x 0,8 mmType of battery Lithium – Ion BatteryDimensions L x W x H: 265 mm x 220 mm x 180 mmTotal filtration: 2.7 mm Al