3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200...

44
Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System 58 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 3.2.3.1 Product description 3.2.3.2 Material specifications 3.2.3.3 Technical data 3.2.3.4 Installation instructions 3.2.3.5 Ordering information 3.2.3.1 Product description Hilti HIT-HY 200 adhesive is an injectable, two-component, hybrid adhesive. The two components are separated by means of a dual-cylinder foil pack attached to a manifold. The two components combine and react when dispensed through a static mixing nozzle attached to the manifold. Hilti HIT-HY 200 adhesive is available in two options, Hilti HIT-HY 200-A, and Hilti HIT-HY 200-R. Both options utilize the same technical data. Hilti HIT-HY 200-A will have shorter working times and curing times than Hilti HIT-HY 200-R. The packaging for each is different which helps the user distinguish between the two adhesives. Hilti HIT-HY 200 adhesive comes with three hole cleaning options: The traditional hole cleaning method uses steel wire brushes and compressed air The self-cleaning method uses the Hilti TE-CD or TE-YD Hollow Drill Bits in conjunction with a Hilti vacuum to remove the dust as you drill. The hole is clean and ready for anchor installation. The no-cleaning method requires the use of Hilti HIT-Z and HIT-Z-R threaded anchor rods. If the base material temperature is less than 41° F (5° C) or if diamond core drilling is used, then the drilled hole must be cleaned. Elements that are suitable for use with this system are threaded steel rods, Hilti HIS-(R)N steel internally threaded inserts, steel reinforcing bars and Hilti HIT-Z and HIT-Z-R threaded rods. Product features Two great products with equal performance data User can select product gel time suitability based on temperature of the base material and jobsite time requirements No hole cleaning requirement when installed SafeSet™ hollow drill bit technology No hole cleaning requirement when installing HIT-Z rods in dry conditions ICC-ES approved for cracked concrete and seismic service May be installed in diamond cored holes when addition cleaning steps are employed Guide specifications Injectable adhesive shall be used for installation of threaded rods (rebar) (inserts) into existing concrete. Adhesive shall be furnished in containers which keep component A and component B separate. Containers shall be designed to accept static mixing nozzle which thoroughly blends component A and component B and allows injection of the mixed adhesive directly into the drilled hole. Only injection tools and static mixing nozzles supplied by the manufacturer may be used. Injection adhesive shall be formulated to include the resin and hardener to provide optimal curing speed, high strength and stiffness. Injection adhesive anchor system shall be Hilti HIT-HY 200 installed using Hilti Safe Set TM Technology. HIT-HY 200 System shall be supplied by Hilti. Listings/Approvals ICC-ES (International code council) ESR-3187 LEED ® Credit 4.1-Low Emitting Materials The Leadership in Energy and Environmental Design ( LEED ® ) Green Building Rating system TM is the nationally accepted benchmark for the design, construction and operation of high performance green buildings. Independent code evaluation IBC ® /IRC ® 2009 IBC ® /IRC ® 2006 IBC ® /IRC ® 2003 HIT-HY 200-A HIT-HY 200-R

Transcript of 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200...

Page 1: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

58 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

3231 Product description

3232 Material specifications

3233 Technical data

3234 Installation instructions

3235 Ordering information

3231 Product description

Hilti HIT-HY 200 adhesive is an injectable two-component hybrid adhesive The two components are separated by means of a dual-cylinder foil pack attached to a manifold The two components combine and react when dispensed through a static mixing nozzle attached to the manifold

Hilti HIT-HY 200 adhesive is available in two options Hilti HIT-HY 200-A and HiltiHIT-HY200-RBothoptionsutilizethe same technical data Hilti HIT-HY 200-A will have shorter working times and curing times than Hilti HIT-HY 200-R The packaging for each is different which helps the user distinguish between the two adhesives

Hilti HIT-HY 200 adhesive comes with three hole cleaning options

bull The traditional hole cleaning method uses steel wire brushes and compressed air

bull The self-cleaning method uses theHiltiTE-CDorTE-YDHollowDrillBitsinconjunctionwithaHiltivacuum to remove the dust as you drill The hole is clean and ready for anchor installation

bull Theno-cleaningmethodrequiresthe use of Hilti HIT-Z and HIT-Z-R threaded anchor rods If the base material temperature is less than 41deg F (5deg C) or if diamond core drilling is used then the drilled hole must be cleaned

Elementsthataresuitableforusewiththis system are threaded steel rods Hilti HIS-(R)N steel internally threaded inserts steel reinforcing bars and Hilti HIT-Z and HIT-Z-R threaded rods

Product features

bull Twogreatproductswithequalperformance data

bull User can select product gel time suitability based on temperature of the base material and jobsite time requirements

bull Noholecleaningrequirementwheninstalled SafeSettrade hollow drill bit technology

bull Noholecleaningrequirementwhen installing HIT-Z rods in dry conditions

bull ICC-ESapprovedforcrackedconcrete and seismic service

bull May be installed in diamond cored holes when addition cleaning steps are employed

Guide specifications

Injectable adhesive shall be used for installation of threaded rods (rebar) (inserts) into existing concrete Adhesive shall be furnished in containers which keepcomponentAandcomponentBseparate Containers shall be designed to accept static mixing nozzle which thoroughly blends component A and componentBandallowsinjectionofthe mixed adhesive directly into the drilled hole Only injection tools and static mixing nozzles supplied by the manufacturer may be used Injection adhesive shall be formulated to include the resin and hardener to provide optimal curing speed high strength and stiffness Injection adhesive anchor system shall be Hilti HIT-HY 200 installed using Hilti Safe SetTM Technology HIT-HY 200 System shall be supplied by Hilti

ListingsApprovalsICC-ES (International code council)ESR-3187

LEEDreg Credit 41-Low Emitting MaterialsTheLeadershipinEnergyandEnvironmentalDesign(LEEDreg) Green BuildingRatingsystemTM is the nationally accepted benchmark for the design construction and operation of high performance green buildings

Independent code evaluationIBCregIRCreg 2009IBCregIRCreg 2006IBCregIRCreg 2003

HIT-HY 200-A

HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 59

328

325

326

327

324

324

324

323

3232 Material specificationsMaterial specifications for the HIT-Z and HIT-Z-R rods are listed in section 32331Material specifications for HAS threaded rods are listed in section 32333Materials specifications for HIS-N and HIS-RN internally threaded inserts are listed in section 32334

3233 Technical dataThe load values contained in this section are Hilti Simplified Design Tables The load tables in this section were developed usingtheStrengthDesignparametersandvariablesofESR-3187andtheequationswithinACI318-11AppendixDForadetailedexplanationoftheHiltiSimplifiedDesignTablesrefertosection317DatatablesfromESR-3187arenotcontainedin this section but can be found at wwwicc-esorg or at wwwushilticom

Figure 1 - HIT-Z and HIT-Z-R installation conditions

Perm

issi

ble

conc

rete

con

ditio

ns

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit 1

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit2

Water-filleddrilled holes

Diamond core drill bit 3

1 Anchor may be installed in a hole drilled with a carbide-tipped bit without cleaning the drilling dust from the hole Temperature must be 41deg F or higher Drilling dust must be removed from the hole if the temperature is below 41deg F See Manufacturerrsquos Published Installation Instructions (MPII)

2Whentemperaturesarebelow41degFTE-CDorTE-YDHollowDrillBitsusedwithaHiltivacuumcleanerareviablemethodsforremovingdrillingdustfrom the hole

3HolesdrilledbydiamondcoringrequirecleaningwithawirebrushawaterhoseandcompressedairSeeMPII

32331 HIT-HY 200 adhesive with HIT-Z and HIT-Z-R threaded rods

Table 1 - HIT-Z and HIT-Z-R specifications

Setting information Symbol UnitsNominal anchor diameter

38 12 58 34Nominal bit diameter do in 716 916 34 78

Effective embedment

minimum hefmin

in 2-38 2-34 3-34 4(mm) 60 70 95 102

maximum hefmax

in 4-12 6 7-12 8-12(mm) 114 152 190 216

Minimum diameter of fixture hole

through-set in 12 58 13161 15161

preset in 716 916 1116 1316

Installationtorque Tinst

ft-lb 15 30 60 110(Nm) (20) (40) (80) (150)

1 Install using (2) washers See Figure 3

Figure 2 - HIT-TZ and HIT-TZ-R specfications

Figure 3 - Installation with (2) washers

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

60 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 2 - HIT-Z and HIT-Z-R anchor rod length and thread dimension

Size

ℓAnchor length

ℓhelix

Helix lengthSmooth shank

length Total thread

lengthUsable thread

lengthin (mm) in (mm) in (mm) in (mm) in (mm)

38 x 4-38 4-38 (111) 2-14 (57) 516 (8) 1-1316 (46) 1-516 (33)

38 x 5-18 5-18 (130) 2-14 (57) 516 (8) 2-916 (65) 2-116 (52)

38 x 6-38 6-38 (162) 2-14 (57) 516 (8) 3-1316 (97) 3-516 (84)

12 x 4-12 4-12 (114) 2-12 (63) 516 (8) 1-1116 (43) 1 (26)

12 x 6-12 6-12 (165) 2-12 (63) 516 (8) 3-1116 (94) 3-116 (77)

12 x 7-34 7-34 (197) 2-12 (63) 516 (8) 4-1516 (126) 4-516 (109)

58 x 6 6 (152) 3-58 (92) 716 (11) 1-1516 (49) 1-18 (28)

58 x 8 8 (203) 3-58 (92) 716 (11) 3-1516 (100) 3-18 (79)

58 x 9-12 9-12 (241) 3-58 (92) 1-1516 (49) 3-1516 (100) 3-18 (79)

34 x 8-12 8-12 (216) 4 (102) 716 (12) 4 (102) 3-116 (77)

34 x 9-34 9-34 (248) 4 (102) 1-1116 (44) 4 (102) 3-116 (77)

HIT-Z carbon steel material specifications38- 12- and 58-in HIT-Z rods are manufactured from AISI 1038 with a minimum tensile strength of 942 ksi (650 MPa) and a minimum yield strength of 753 ksi (520 MPa)34-in HIT-Z rods are manufactured from either AISI 1038 or 18MnV5 with a minimum tensile strength of 942 ksi (650 MPa) and a minimum yield strength of 753 ksi (520 MPa)HIT-Z rods have a electroplate zinc coating with a minimum thickness of 5 micromCarbonsteelnutsconformtoASTMA563andANSIB1822Carbon steel washers conform to ASTM F844

HIT-Z-R stainless steel material specificationsHIT-Z-R rods are manufactured from AISI Type 316 stainless steel minimum tensile strength of 942 ksi (650 MPa) and a mini-mum yield strength of 753 ksi (520 MPa)StainlesssteelnutsconformwithASTMF594andANSIB1822Stainless steel washers are manufactured from AISI Type 316 stainless steel and conform to ASTM A240

Figure 4 - HIT-TZ and HIT-TZ-R anchor rod length and thread dimension

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 61

328

325

326

327

324

324

324

323

Table 3 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in uncracked concrete 1234567810

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3610 4425 3075 3370 3890 4765(60) (127) (139) (161) (197) (137) (150) (173) (212)

3-38 4835 5300 5560 5560 10415 11410 13175 16135(86) (215) (236) (247) (247) (463) (508) (586) (718)

4-12 5560 5560 5560 5560 16035 17570 20285 24845(114) (247) (247) (247) (247) (713) (782) (902) (1105)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8190 8190 16035 17570 20285 24845(114) (331) (363) (364) (364) (713) (782) (902) (1105)

6 8190 8190 8190 8190 24690 27045 31230 38250(152) (364) (364) (364) (364) (1098) (1203) (1389) (1701)

58

3-34 5665 6205 7165 8775 12200 13365 15430 18900(95) (252) (276) (319) (390) (543) (595) (686) (841)

5-58 10405 11400 13165 14950 22415 24550 28350 34720(143) (463) (507) (586) (665) (997) (1092) (1261) (1544)7-12 14950 14950 14950 14950 34505 37800 43650 53455(191) (665) (665) (665) (665) (1535) (1681) (1942) (2378)

34

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)6-34 13680 14985 17305 19890 29460 32275 37265 45645(171) (609) (667) (770) (885) (1310) (1436) (1658) (2030)8-12 19330 19890 19890 19890 41635 45605 52660 64500(216) (860) (885) (885) (885) (1852) (2029) (2342) (2869)

Table 4 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in cracked concrete 12345678910

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2020 2215 2560 3135 2180 2385 2755 3375(60) (90) (99) (114) (139) (97) (106) (123) (150)

3-38 3425 3755 4335 5305 7380 8085 9335 11430(86) (152) (167) (193) (236) (328) (360) (415) (508)

4-12 5275 5560 5560 5560 11360 12445 14370 17600(114) (235) (247) (247) (247) (505) (554) (639) (783)

12

2-34 2520 2760 3185 3905 5425 5945 6865 8405(70) (112) (123) (142) (174) (241) (264) (305) (374)

4-12 5275 5780 6670 7640 11360 12445 14370 17600(114) (235) (257) (297) (340) (505) (554) (639) (783)

6 7640 7640 7640 7640 17490 19160 22120 27095(152) (340) (340) (340) (340) (778) (852) (984) (1205)

58

3-34 4010 4395 5075 6215 8640 9465 10930 13390(95) (178) (195) (226) (276) (384) (421) (486) (596)

5-58 7370 8075 9325 11420 15875 17390 20080 24595(143) (328) (359) (415) (508) (706) (774) (893) (1094)7-12 11350 12430 14355 14950 24440 26775 30915 37865(191) (505) (553) (639) (665) (1087) (1191) (1375) (1684)

34

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)6-34 9690 10615 12255 15010 20870 22860 26395 32330(171) (431) (472) (545) (668) (928) (1017) (1174) (1438)8-12 13690 15000 17320 19535 29490 32305 37300 45685(216) (609) (667) (770) (869) (1312) (1437) (1659) (2032)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 10 - 17 as necessary Compare to the steel values in table 5 The lesser of the values is to be used for

the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C)

FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby086 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long-term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry and water saturated concrete conditions7 Tabular values are for short-term loads only For sustained loads see section 31758 Tabularvaluesarefornormal-weightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors

38-indiameter-αseis = 0705 12-into34-indiameter-αseis = 075 See Section 3174 for additional information on seismic applications

10 Diamond core drilling with Hilti HIT-Z(-R) rods is permitted with no reduction in published data above

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

62 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 5 - Steel design strength for Hilti HIT-Z and HIT-Z-R rods 12

Nominal anchor diameter

in

ACI318AppendixDBasedDesignHIT-Z carbon steel rod HIT-Z-R stainless steel rod

Tensile3ϕNsalb (kN)

Shear4ϕVsalb (kN) αseisV

5Tensile3ϕNsa

lb (kN)Shear4ϕVsa

lb (kN) αseisV5

384750 1930

104750 2630

10(211) (86) (211) (117)

128695 3530

0658695 4815

075(387) (157) (387) (214)

5813850 5625

06513850 7670

065(616) (250) (616) (341)

3420455 8310

06520455 11330

065(910) (370) (910) (504)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Hilti HIT-Z(-R) rod permissible combinations of edge distance snchor spacing and concrete thicknessTheHiltiHIT-ZandHIT-Z-RRodsproducehigherexpansionforcesintheconcreteslabwhentheinstallationtorqueisappliedThis means that the anchor must be installed with larger edge distances and spacing when compared to standard threaded rod to minimize the likelihood that the concrete slab will split during installation

The permissible edge distance is based on the concrete condition (cracked or uncracked) the concrete thickness and anchor spacing if designing for anchor groups The permissible concrete thickness is dependent on whether or not the drill dust is removed during the anchor installation process

Step 1 Check concrete thickness

When using Hilti HIT-Z and HIT-Z-R rods drilling dust does not need to be removed for optimum capacity when base material temperatures are greater than 41deg F (5deg C) and a hammer drill with a carbide tipped drill bit is used However concrete thickness can be reduced if the drilling dust is removed The figure below shows both drilled hole conditions Drilled hole condition 1 illustrates the hole depth and concrete thickness when drilling dust is left in the hole Drilled hole condition 2 illustratesthecorrespondingreductionwhendrilldustisremovedbyusingcompressedairHiltiTE-CDorTE-YDHollowDrillBitswithaHiltivacuum

Step 2 Check edge distance and anchor spacing

Tables 6 to 9 in this section show the minimum edge distance and anchor spacing based on a specific concrete thickness and whether or not the design is for cracked or uncracked concrete There are two cases of edge distance and anchor spacing combinations for each embedment and concrete condition (cracked or uncracked) Case 1 is the minimum edge distance needed for one anchor or for two anchors with large anchor spacing Case 2 is the minimum anchor spacing that can be used but the edge distance is increased to help prevent splitting Linear interpolation can be used between Case 1 and Case 2 for any specific concrete thickness and concrete condition See the following figure and calculation which can be used to deter-mine specific edge distance and anchor spacing combinations

Refer to tables 6 to 9 in this section for the minimum concrete thicknesses associated with the Hilti HIT-Z(-R) rods based on diameter and drilled hole condition

Figure 5

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 63

328

325

326

327

324

324

324

323

For a specific edge distance the permitted spacing is calculated as follows

(smin1 ndash smin2)sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

Table 6 - Minimum edge distance spacing and concrete thickness for 38-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 38

Effectiveembedment hef

in 2-38 3-38 4-12(mm) (60) (86) (114)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 4-58 5-34 4-58 5-58 6-38 5-34 6-34 7-38

(mm) (102) (117) (146) (117) (143) (162) (146) (171) (187)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 3-18 2-34 2-14 2-34 2-14 2 2-14 1-78 1-78(mm) (79) (70) (57) (70) (57) (51) (57) (48) (48)

s min1

in 9-18 7-34 6-18 7-34 6-12 5-58 6-18 5-38 4-12(mm) (232) (197) (156) (197) (165) (143) (156) (137) (114)

Minimum edge andspacingCase 2

c min2

in 5-58 4-34 3-34 4-34 3-78 3-14 3-34 3-18 2-34(mm) (143) (121) (95) (121) (98) (83) (95) (79) (70)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 2-18 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (54) (48) (48) (48) (48) (48) (48) (48) (48)

s min1

in 6-38 5-12 4-14 5-12 3-12 2-58 3-14 2 1-78(mm) (162) (140) (108) (140) (89) (67) (83) (51) (48)

Minimum edge andspacingCase 2

c min2

in 3-58 3-18 2-38 3-18 2-12 2-18 2-38 2 1-78(mm) (92) (79) (60) (79) (64) (54) (60) (51) (48)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Table 7 - Minimum edge distance spacing and concrete thickness for 12-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 12

Effectiveembedment hef

in 2-34 4-12 6(mm) (70) (114) (152)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 5 7-18 5-34 6-34 8-14 7-14 8-14 9-34

(mm) (102) (127) (181) (146) (171) (210) (184) (210) (248)

Unc

rack

ed C

oncr

ete Minimum edge and

spacingCase 1

c min1

in 5-18 4-18 2-78 3-58 3 2-12 2-78 2-12 2-12(mm) (130) (105) (73) (92) (76) (64) (73) (64) (64)

s min1

in 14-78 11-78 8-58 10-14 9 7-14 8-18 7-14 5(mm) (378) (302) (219) (260) (229) (184) (206) (184) (127)

Minimum edge andspacingCase 2

c min2

in 9-14 7-14 4-78 6-14 5-14 4-18 4-34 4-18 3-38(mm) (235) (184) (124) (159) (133) (105) (121) (105) (86)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

Cra

cked

Con

cret

e Minimum edge andspacingCase 1

c min1

in 3-58 3 2-12 2-58 2-12 2-12 2-12 2-12 2-12(mm) (92) (76) (64) (67) (64) (64) (64) (64) (64)

s min1

in 10-78 8-12 6 7-38 5-12 3-18 4-12 3-18 2-12(mm) (276) (216) (152) (187) (140) (79) (114) (79) (64)

Minimum edge andspacingCase 2

c min2

in 6-12 5 3-14 4-14 3-12 2-34 3-14 2-34 2-12(mm) (165) (127) (83) (108) (89) (70) (83) (70) (64)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Concrete Edge

Anchors not permitted in shaded area

Smin2

Smin1

Cm

in1

Cm

in2

Case 1

Case 2

cdesignedge distance c

caminatsge

sminatcgesdesign

spac

ing

s

Figure 6

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

64 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 8 - Minimum edge distance spacing and concrete thickness for 58-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 58

Effectiveembedment hef

in 3-34 5-58 7-12(mm) (95) (143) (191)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-12 7-34 9-38 7-38 9-58 10-12 9-14 11-12 12-14

(mm) (140) (197) (238) (187) (244) (267) (235) (292) (311)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 6-14 4-12 3-34 4-58 3-58 3-14 3-34 3-18 3-18(mm) (159) (114) (95) (117) (92) (83) (95) (79) (79)

s min1

in 18-38 12-78 10-58 13-78 10-38 9-34 10-78 8-38 7-38(mm) (467) (327) (270) (352) (264) (248) (276) (213) (187)

Minimum edge andspacingCase 2

c min2

in 11-38 7-34 6-14 8-14 6-18 5-12 6-38 4-78 4-58(mm) (289) (197) (159) (210) (156) (140) (162) (124) (117)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 4-58 3-38 3-18 3-12 3-18 3-18 3-18 3-18 3-18(mm) (117) (86) (79) (89) (79) (79) (79) (79) (79)

s min1

in 13-78 9-12 8-34 10-18 6-12 5-38 7-18 3-78 3-18(mm) (352) (241) (222) (257) (165) (137) (181) (98) (79)

Minimum edge andspacingCase 2

c min2

in 8-14 5-12 4-38 5-78 4-14 3-78 4-12 3-38 3-18(mm) (210) (140) (111) (149) (108) (98) (114) (86) (79)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Table 9 - Minimum edge distance spacing and concrete thickness for 34-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 34

Effectiveembedment hef

in 4 6-34 8-12(mm) (102) (171) (216)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-34 8 11-12 8-12 10-34 13-18 10-14 12-12 14-12

(mm) (146) (203) (292) (216) (273) (333) (260) (318) (368)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 9-34 7 5 6-58 5-14 4-14 5-12 4-12 4(mm) (248) (178) (127) (168) (133) (108) (140) (114) (102)

s min1

in 28-34 20-58 14 19-38 15-14 12-58 16 13-14 11(mm) (730) (524) (356) (492) (387) (321) (406) (337) (279)

Minimum edge andspacingCase 2

c min2

in 18-18 12-58 8-12 11-78 9-18 7-14 9-58 7-34 6-12(mm) (460) (321) (216) (302) (232) (184) (244) (197) (165)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 7-14 5-14 4-18 5 4 3-34 4-18 3-34 3-34(mm) (184) (133) (105) (127) (102) (95) (105) (95) (95)

s min1

in 21-34 15-12 12-14 14-12 11-38 9 12-18 8-34 6-12(mm) (552) (394) (311) (368) (289) (229) (308) (222) (165)

Minimum edge andspacingCase 2

c min2

in 13-14 9-14 6 8-58 6-58 5-18 7 5-12 4-12(mm) (337) (235) (152) (219) (168) (130) (178) (140) (114)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 2: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 59

328

325

326

327

324

324

324

323

3232 Material specificationsMaterial specifications for the HIT-Z and HIT-Z-R rods are listed in section 32331Material specifications for HAS threaded rods are listed in section 32333Materials specifications for HIS-N and HIS-RN internally threaded inserts are listed in section 32334

3233 Technical dataThe load values contained in this section are Hilti Simplified Design Tables The load tables in this section were developed usingtheStrengthDesignparametersandvariablesofESR-3187andtheequationswithinACI318-11AppendixDForadetailedexplanationoftheHiltiSimplifiedDesignTablesrefertosection317DatatablesfromESR-3187arenotcontainedin this section but can be found at wwwicc-esorg or at wwwushilticom

Figure 1 - HIT-Z and HIT-Z-R installation conditions

Perm

issi

ble

conc

rete

con

ditio

ns

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit 1

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit2

Water-filleddrilled holes

Diamond core drill bit 3

1 Anchor may be installed in a hole drilled with a carbide-tipped bit without cleaning the drilling dust from the hole Temperature must be 41deg F or higher Drilling dust must be removed from the hole if the temperature is below 41deg F See Manufacturerrsquos Published Installation Instructions (MPII)

2Whentemperaturesarebelow41degFTE-CDorTE-YDHollowDrillBitsusedwithaHiltivacuumcleanerareviablemethodsforremovingdrillingdustfrom the hole

3HolesdrilledbydiamondcoringrequirecleaningwithawirebrushawaterhoseandcompressedairSeeMPII

32331 HIT-HY 200 adhesive with HIT-Z and HIT-Z-R threaded rods

Table 1 - HIT-Z and HIT-Z-R specifications

Setting information Symbol UnitsNominal anchor diameter

38 12 58 34Nominal bit diameter do in 716 916 34 78

Effective embedment

minimum hefmin

in 2-38 2-34 3-34 4(mm) 60 70 95 102

maximum hefmax

in 4-12 6 7-12 8-12(mm) 114 152 190 216

Minimum diameter of fixture hole

through-set in 12 58 13161 15161

preset in 716 916 1116 1316

Installationtorque Tinst

ft-lb 15 30 60 110(Nm) (20) (40) (80) (150)

1 Install using (2) washers See Figure 3

Figure 2 - HIT-TZ and HIT-TZ-R specfications

Figure 3 - Installation with (2) washers

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

60 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 2 - HIT-Z and HIT-Z-R anchor rod length and thread dimension

Size

ℓAnchor length

ℓhelix

Helix lengthSmooth shank

length Total thread

lengthUsable thread

lengthin (mm) in (mm) in (mm) in (mm) in (mm)

38 x 4-38 4-38 (111) 2-14 (57) 516 (8) 1-1316 (46) 1-516 (33)

38 x 5-18 5-18 (130) 2-14 (57) 516 (8) 2-916 (65) 2-116 (52)

38 x 6-38 6-38 (162) 2-14 (57) 516 (8) 3-1316 (97) 3-516 (84)

12 x 4-12 4-12 (114) 2-12 (63) 516 (8) 1-1116 (43) 1 (26)

12 x 6-12 6-12 (165) 2-12 (63) 516 (8) 3-1116 (94) 3-116 (77)

12 x 7-34 7-34 (197) 2-12 (63) 516 (8) 4-1516 (126) 4-516 (109)

58 x 6 6 (152) 3-58 (92) 716 (11) 1-1516 (49) 1-18 (28)

58 x 8 8 (203) 3-58 (92) 716 (11) 3-1516 (100) 3-18 (79)

58 x 9-12 9-12 (241) 3-58 (92) 1-1516 (49) 3-1516 (100) 3-18 (79)

34 x 8-12 8-12 (216) 4 (102) 716 (12) 4 (102) 3-116 (77)

34 x 9-34 9-34 (248) 4 (102) 1-1116 (44) 4 (102) 3-116 (77)

HIT-Z carbon steel material specifications38- 12- and 58-in HIT-Z rods are manufactured from AISI 1038 with a minimum tensile strength of 942 ksi (650 MPa) and a minimum yield strength of 753 ksi (520 MPa)34-in HIT-Z rods are manufactured from either AISI 1038 or 18MnV5 with a minimum tensile strength of 942 ksi (650 MPa) and a minimum yield strength of 753 ksi (520 MPa)HIT-Z rods have a electroplate zinc coating with a minimum thickness of 5 micromCarbonsteelnutsconformtoASTMA563andANSIB1822Carbon steel washers conform to ASTM F844

HIT-Z-R stainless steel material specificationsHIT-Z-R rods are manufactured from AISI Type 316 stainless steel minimum tensile strength of 942 ksi (650 MPa) and a mini-mum yield strength of 753 ksi (520 MPa)StainlesssteelnutsconformwithASTMF594andANSIB1822Stainless steel washers are manufactured from AISI Type 316 stainless steel and conform to ASTM A240

Figure 4 - HIT-TZ and HIT-TZ-R anchor rod length and thread dimension

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 61

328

325

326

327

324

324

324

323

Table 3 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in uncracked concrete 1234567810

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3610 4425 3075 3370 3890 4765(60) (127) (139) (161) (197) (137) (150) (173) (212)

3-38 4835 5300 5560 5560 10415 11410 13175 16135(86) (215) (236) (247) (247) (463) (508) (586) (718)

4-12 5560 5560 5560 5560 16035 17570 20285 24845(114) (247) (247) (247) (247) (713) (782) (902) (1105)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8190 8190 16035 17570 20285 24845(114) (331) (363) (364) (364) (713) (782) (902) (1105)

6 8190 8190 8190 8190 24690 27045 31230 38250(152) (364) (364) (364) (364) (1098) (1203) (1389) (1701)

58

3-34 5665 6205 7165 8775 12200 13365 15430 18900(95) (252) (276) (319) (390) (543) (595) (686) (841)

5-58 10405 11400 13165 14950 22415 24550 28350 34720(143) (463) (507) (586) (665) (997) (1092) (1261) (1544)7-12 14950 14950 14950 14950 34505 37800 43650 53455(191) (665) (665) (665) (665) (1535) (1681) (1942) (2378)

34

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)6-34 13680 14985 17305 19890 29460 32275 37265 45645(171) (609) (667) (770) (885) (1310) (1436) (1658) (2030)8-12 19330 19890 19890 19890 41635 45605 52660 64500(216) (860) (885) (885) (885) (1852) (2029) (2342) (2869)

Table 4 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in cracked concrete 12345678910

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2020 2215 2560 3135 2180 2385 2755 3375(60) (90) (99) (114) (139) (97) (106) (123) (150)

3-38 3425 3755 4335 5305 7380 8085 9335 11430(86) (152) (167) (193) (236) (328) (360) (415) (508)

4-12 5275 5560 5560 5560 11360 12445 14370 17600(114) (235) (247) (247) (247) (505) (554) (639) (783)

12

2-34 2520 2760 3185 3905 5425 5945 6865 8405(70) (112) (123) (142) (174) (241) (264) (305) (374)

4-12 5275 5780 6670 7640 11360 12445 14370 17600(114) (235) (257) (297) (340) (505) (554) (639) (783)

6 7640 7640 7640 7640 17490 19160 22120 27095(152) (340) (340) (340) (340) (778) (852) (984) (1205)

58

3-34 4010 4395 5075 6215 8640 9465 10930 13390(95) (178) (195) (226) (276) (384) (421) (486) (596)

5-58 7370 8075 9325 11420 15875 17390 20080 24595(143) (328) (359) (415) (508) (706) (774) (893) (1094)7-12 11350 12430 14355 14950 24440 26775 30915 37865(191) (505) (553) (639) (665) (1087) (1191) (1375) (1684)

34

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)6-34 9690 10615 12255 15010 20870 22860 26395 32330(171) (431) (472) (545) (668) (928) (1017) (1174) (1438)8-12 13690 15000 17320 19535 29490 32305 37300 45685(216) (609) (667) (770) (869) (1312) (1437) (1659) (2032)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 10 - 17 as necessary Compare to the steel values in table 5 The lesser of the values is to be used for

the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C)

FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby086 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long-term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry and water saturated concrete conditions7 Tabular values are for short-term loads only For sustained loads see section 31758 Tabularvaluesarefornormal-weightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors

38-indiameter-αseis = 0705 12-into34-indiameter-αseis = 075 See Section 3174 for additional information on seismic applications

10 Diamond core drilling with Hilti HIT-Z(-R) rods is permitted with no reduction in published data above

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

62 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 5 - Steel design strength for Hilti HIT-Z and HIT-Z-R rods 12

Nominal anchor diameter

in

ACI318AppendixDBasedDesignHIT-Z carbon steel rod HIT-Z-R stainless steel rod

Tensile3ϕNsalb (kN)

Shear4ϕVsalb (kN) αseisV

5Tensile3ϕNsa

lb (kN)Shear4ϕVsa

lb (kN) αseisV5

384750 1930

104750 2630

10(211) (86) (211) (117)

128695 3530

0658695 4815

075(387) (157) (387) (214)

5813850 5625

06513850 7670

065(616) (250) (616) (341)

3420455 8310

06520455 11330

065(910) (370) (910) (504)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Hilti HIT-Z(-R) rod permissible combinations of edge distance snchor spacing and concrete thicknessTheHiltiHIT-ZandHIT-Z-RRodsproducehigherexpansionforcesintheconcreteslabwhentheinstallationtorqueisappliedThis means that the anchor must be installed with larger edge distances and spacing when compared to standard threaded rod to minimize the likelihood that the concrete slab will split during installation

The permissible edge distance is based on the concrete condition (cracked or uncracked) the concrete thickness and anchor spacing if designing for anchor groups The permissible concrete thickness is dependent on whether or not the drill dust is removed during the anchor installation process

Step 1 Check concrete thickness

When using Hilti HIT-Z and HIT-Z-R rods drilling dust does not need to be removed for optimum capacity when base material temperatures are greater than 41deg F (5deg C) and a hammer drill with a carbide tipped drill bit is used However concrete thickness can be reduced if the drilling dust is removed The figure below shows both drilled hole conditions Drilled hole condition 1 illustrates the hole depth and concrete thickness when drilling dust is left in the hole Drilled hole condition 2 illustratesthecorrespondingreductionwhendrilldustisremovedbyusingcompressedairHiltiTE-CDorTE-YDHollowDrillBitswithaHiltivacuum

Step 2 Check edge distance and anchor spacing

Tables 6 to 9 in this section show the minimum edge distance and anchor spacing based on a specific concrete thickness and whether or not the design is for cracked or uncracked concrete There are two cases of edge distance and anchor spacing combinations for each embedment and concrete condition (cracked or uncracked) Case 1 is the minimum edge distance needed for one anchor or for two anchors with large anchor spacing Case 2 is the minimum anchor spacing that can be used but the edge distance is increased to help prevent splitting Linear interpolation can be used between Case 1 and Case 2 for any specific concrete thickness and concrete condition See the following figure and calculation which can be used to deter-mine specific edge distance and anchor spacing combinations

Refer to tables 6 to 9 in this section for the minimum concrete thicknesses associated with the Hilti HIT-Z(-R) rods based on diameter and drilled hole condition

Figure 5

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 63

328

325

326

327

324

324

324

323

For a specific edge distance the permitted spacing is calculated as follows

(smin1 ndash smin2)sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

Table 6 - Minimum edge distance spacing and concrete thickness for 38-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 38

Effectiveembedment hef

in 2-38 3-38 4-12(mm) (60) (86) (114)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 4-58 5-34 4-58 5-58 6-38 5-34 6-34 7-38

(mm) (102) (117) (146) (117) (143) (162) (146) (171) (187)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 3-18 2-34 2-14 2-34 2-14 2 2-14 1-78 1-78(mm) (79) (70) (57) (70) (57) (51) (57) (48) (48)

s min1

in 9-18 7-34 6-18 7-34 6-12 5-58 6-18 5-38 4-12(mm) (232) (197) (156) (197) (165) (143) (156) (137) (114)

Minimum edge andspacingCase 2

c min2

in 5-58 4-34 3-34 4-34 3-78 3-14 3-34 3-18 2-34(mm) (143) (121) (95) (121) (98) (83) (95) (79) (70)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 2-18 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (54) (48) (48) (48) (48) (48) (48) (48) (48)

s min1

in 6-38 5-12 4-14 5-12 3-12 2-58 3-14 2 1-78(mm) (162) (140) (108) (140) (89) (67) (83) (51) (48)

Minimum edge andspacingCase 2

c min2

in 3-58 3-18 2-38 3-18 2-12 2-18 2-38 2 1-78(mm) (92) (79) (60) (79) (64) (54) (60) (51) (48)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Table 7 - Minimum edge distance spacing and concrete thickness for 12-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 12

Effectiveembedment hef

in 2-34 4-12 6(mm) (70) (114) (152)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 5 7-18 5-34 6-34 8-14 7-14 8-14 9-34

(mm) (102) (127) (181) (146) (171) (210) (184) (210) (248)

Unc

rack

ed C

oncr

ete Minimum edge and

spacingCase 1

c min1

in 5-18 4-18 2-78 3-58 3 2-12 2-78 2-12 2-12(mm) (130) (105) (73) (92) (76) (64) (73) (64) (64)

s min1

in 14-78 11-78 8-58 10-14 9 7-14 8-18 7-14 5(mm) (378) (302) (219) (260) (229) (184) (206) (184) (127)

Minimum edge andspacingCase 2

c min2

in 9-14 7-14 4-78 6-14 5-14 4-18 4-34 4-18 3-38(mm) (235) (184) (124) (159) (133) (105) (121) (105) (86)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

Cra

cked

Con

cret

e Minimum edge andspacingCase 1

c min1

in 3-58 3 2-12 2-58 2-12 2-12 2-12 2-12 2-12(mm) (92) (76) (64) (67) (64) (64) (64) (64) (64)

s min1

in 10-78 8-12 6 7-38 5-12 3-18 4-12 3-18 2-12(mm) (276) (216) (152) (187) (140) (79) (114) (79) (64)

Minimum edge andspacingCase 2

c min2

in 6-12 5 3-14 4-14 3-12 2-34 3-14 2-34 2-12(mm) (165) (127) (83) (108) (89) (70) (83) (70) (64)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Concrete Edge

Anchors not permitted in shaded area

Smin2

Smin1

Cm

in1

Cm

in2

Case 1

Case 2

cdesignedge distance c

caminatsge

sminatcgesdesign

spac

ing

s

Figure 6

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

64 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 8 - Minimum edge distance spacing and concrete thickness for 58-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 58

Effectiveembedment hef

in 3-34 5-58 7-12(mm) (95) (143) (191)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-12 7-34 9-38 7-38 9-58 10-12 9-14 11-12 12-14

(mm) (140) (197) (238) (187) (244) (267) (235) (292) (311)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 6-14 4-12 3-34 4-58 3-58 3-14 3-34 3-18 3-18(mm) (159) (114) (95) (117) (92) (83) (95) (79) (79)

s min1

in 18-38 12-78 10-58 13-78 10-38 9-34 10-78 8-38 7-38(mm) (467) (327) (270) (352) (264) (248) (276) (213) (187)

Minimum edge andspacingCase 2

c min2

in 11-38 7-34 6-14 8-14 6-18 5-12 6-38 4-78 4-58(mm) (289) (197) (159) (210) (156) (140) (162) (124) (117)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 4-58 3-38 3-18 3-12 3-18 3-18 3-18 3-18 3-18(mm) (117) (86) (79) (89) (79) (79) (79) (79) (79)

s min1

in 13-78 9-12 8-34 10-18 6-12 5-38 7-18 3-78 3-18(mm) (352) (241) (222) (257) (165) (137) (181) (98) (79)

Minimum edge andspacingCase 2

c min2

in 8-14 5-12 4-38 5-78 4-14 3-78 4-12 3-38 3-18(mm) (210) (140) (111) (149) (108) (98) (114) (86) (79)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Table 9 - Minimum edge distance spacing and concrete thickness for 34-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 34

Effectiveembedment hef

in 4 6-34 8-12(mm) (102) (171) (216)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-34 8 11-12 8-12 10-34 13-18 10-14 12-12 14-12

(mm) (146) (203) (292) (216) (273) (333) (260) (318) (368)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 9-34 7 5 6-58 5-14 4-14 5-12 4-12 4(mm) (248) (178) (127) (168) (133) (108) (140) (114) (102)

s min1

in 28-34 20-58 14 19-38 15-14 12-58 16 13-14 11(mm) (730) (524) (356) (492) (387) (321) (406) (337) (279)

Minimum edge andspacingCase 2

c min2

in 18-18 12-58 8-12 11-78 9-18 7-14 9-58 7-34 6-12(mm) (460) (321) (216) (302) (232) (184) (244) (197) (165)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 7-14 5-14 4-18 5 4 3-34 4-18 3-34 3-34(mm) (184) (133) (105) (127) (102) (95) (105) (95) (95)

s min1

in 21-34 15-12 12-14 14-12 11-38 9 12-18 8-34 6-12(mm) (552) (394) (311) (368) (289) (229) (308) (222) (165)

Minimum edge andspacingCase 2

c min2

in 13-14 9-14 6 8-58 6-58 5-18 7 5-12 4-12(mm) (337) (235) (152) (219) (168) (130) (178) (140) (114)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 3: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

60 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 2 - HIT-Z and HIT-Z-R anchor rod length and thread dimension

Size

ℓAnchor length

ℓhelix

Helix lengthSmooth shank

length Total thread

lengthUsable thread

lengthin (mm) in (mm) in (mm) in (mm) in (mm)

38 x 4-38 4-38 (111) 2-14 (57) 516 (8) 1-1316 (46) 1-516 (33)

38 x 5-18 5-18 (130) 2-14 (57) 516 (8) 2-916 (65) 2-116 (52)

38 x 6-38 6-38 (162) 2-14 (57) 516 (8) 3-1316 (97) 3-516 (84)

12 x 4-12 4-12 (114) 2-12 (63) 516 (8) 1-1116 (43) 1 (26)

12 x 6-12 6-12 (165) 2-12 (63) 516 (8) 3-1116 (94) 3-116 (77)

12 x 7-34 7-34 (197) 2-12 (63) 516 (8) 4-1516 (126) 4-516 (109)

58 x 6 6 (152) 3-58 (92) 716 (11) 1-1516 (49) 1-18 (28)

58 x 8 8 (203) 3-58 (92) 716 (11) 3-1516 (100) 3-18 (79)

58 x 9-12 9-12 (241) 3-58 (92) 1-1516 (49) 3-1516 (100) 3-18 (79)

34 x 8-12 8-12 (216) 4 (102) 716 (12) 4 (102) 3-116 (77)

34 x 9-34 9-34 (248) 4 (102) 1-1116 (44) 4 (102) 3-116 (77)

HIT-Z carbon steel material specifications38- 12- and 58-in HIT-Z rods are manufactured from AISI 1038 with a minimum tensile strength of 942 ksi (650 MPa) and a minimum yield strength of 753 ksi (520 MPa)34-in HIT-Z rods are manufactured from either AISI 1038 or 18MnV5 with a minimum tensile strength of 942 ksi (650 MPa) and a minimum yield strength of 753 ksi (520 MPa)HIT-Z rods have a electroplate zinc coating with a minimum thickness of 5 micromCarbonsteelnutsconformtoASTMA563andANSIB1822Carbon steel washers conform to ASTM F844

HIT-Z-R stainless steel material specificationsHIT-Z-R rods are manufactured from AISI Type 316 stainless steel minimum tensile strength of 942 ksi (650 MPa) and a mini-mum yield strength of 753 ksi (520 MPa)StainlesssteelnutsconformwithASTMF594andANSIB1822Stainless steel washers are manufactured from AISI Type 316 stainless steel and conform to ASTM A240

Figure 4 - HIT-TZ and HIT-TZ-R anchor rod length and thread dimension

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 61

328

325

326

327

324

324

324

323

Table 3 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in uncracked concrete 1234567810

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3610 4425 3075 3370 3890 4765(60) (127) (139) (161) (197) (137) (150) (173) (212)

3-38 4835 5300 5560 5560 10415 11410 13175 16135(86) (215) (236) (247) (247) (463) (508) (586) (718)

4-12 5560 5560 5560 5560 16035 17570 20285 24845(114) (247) (247) (247) (247) (713) (782) (902) (1105)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8190 8190 16035 17570 20285 24845(114) (331) (363) (364) (364) (713) (782) (902) (1105)

6 8190 8190 8190 8190 24690 27045 31230 38250(152) (364) (364) (364) (364) (1098) (1203) (1389) (1701)

58

3-34 5665 6205 7165 8775 12200 13365 15430 18900(95) (252) (276) (319) (390) (543) (595) (686) (841)

5-58 10405 11400 13165 14950 22415 24550 28350 34720(143) (463) (507) (586) (665) (997) (1092) (1261) (1544)7-12 14950 14950 14950 14950 34505 37800 43650 53455(191) (665) (665) (665) (665) (1535) (1681) (1942) (2378)

34

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)6-34 13680 14985 17305 19890 29460 32275 37265 45645(171) (609) (667) (770) (885) (1310) (1436) (1658) (2030)8-12 19330 19890 19890 19890 41635 45605 52660 64500(216) (860) (885) (885) (885) (1852) (2029) (2342) (2869)

Table 4 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in cracked concrete 12345678910

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2020 2215 2560 3135 2180 2385 2755 3375(60) (90) (99) (114) (139) (97) (106) (123) (150)

3-38 3425 3755 4335 5305 7380 8085 9335 11430(86) (152) (167) (193) (236) (328) (360) (415) (508)

4-12 5275 5560 5560 5560 11360 12445 14370 17600(114) (235) (247) (247) (247) (505) (554) (639) (783)

12

2-34 2520 2760 3185 3905 5425 5945 6865 8405(70) (112) (123) (142) (174) (241) (264) (305) (374)

4-12 5275 5780 6670 7640 11360 12445 14370 17600(114) (235) (257) (297) (340) (505) (554) (639) (783)

6 7640 7640 7640 7640 17490 19160 22120 27095(152) (340) (340) (340) (340) (778) (852) (984) (1205)

58

3-34 4010 4395 5075 6215 8640 9465 10930 13390(95) (178) (195) (226) (276) (384) (421) (486) (596)

5-58 7370 8075 9325 11420 15875 17390 20080 24595(143) (328) (359) (415) (508) (706) (774) (893) (1094)7-12 11350 12430 14355 14950 24440 26775 30915 37865(191) (505) (553) (639) (665) (1087) (1191) (1375) (1684)

34

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)6-34 9690 10615 12255 15010 20870 22860 26395 32330(171) (431) (472) (545) (668) (928) (1017) (1174) (1438)8-12 13690 15000 17320 19535 29490 32305 37300 45685(216) (609) (667) (770) (869) (1312) (1437) (1659) (2032)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 10 - 17 as necessary Compare to the steel values in table 5 The lesser of the values is to be used for

the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C)

FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby086 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long-term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry and water saturated concrete conditions7 Tabular values are for short-term loads only For sustained loads see section 31758 Tabularvaluesarefornormal-weightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors

38-indiameter-αseis = 0705 12-into34-indiameter-αseis = 075 See Section 3174 for additional information on seismic applications

10 Diamond core drilling with Hilti HIT-Z(-R) rods is permitted with no reduction in published data above

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

62 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 5 - Steel design strength for Hilti HIT-Z and HIT-Z-R rods 12

Nominal anchor diameter

in

ACI318AppendixDBasedDesignHIT-Z carbon steel rod HIT-Z-R stainless steel rod

Tensile3ϕNsalb (kN)

Shear4ϕVsalb (kN) αseisV

5Tensile3ϕNsa

lb (kN)Shear4ϕVsa

lb (kN) αseisV5

384750 1930

104750 2630

10(211) (86) (211) (117)

128695 3530

0658695 4815

075(387) (157) (387) (214)

5813850 5625

06513850 7670

065(616) (250) (616) (341)

3420455 8310

06520455 11330

065(910) (370) (910) (504)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Hilti HIT-Z(-R) rod permissible combinations of edge distance snchor spacing and concrete thicknessTheHiltiHIT-ZandHIT-Z-RRodsproducehigherexpansionforcesintheconcreteslabwhentheinstallationtorqueisappliedThis means that the anchor must be installed with larger edge distances and spacing when compared to standard threaded rod to minimize the likelihood that the concrete slab will split during installation

The permissible edge distance is based on the concrete condition (cracked or uncracked) the concrete thickness and anchor spacing if designing for anchor groups The permissible concrete thickness is dependent on whether or not the drill dust is removed during the anchor installation process

Step 1 Check concrete thickness

When using Hilti HIT-Z and HIT-Z-R rods drilling dust does not need to be removed for optimum capacity when base material temperatures are greater than 41deg F (5deg C) and a hammer drill with a carbide tipped drill bit is used However concrete thickness can be reduced if the drilling dust is removed The figure below shows both drilled hole conditions Drilled hole condition 1 illustrates the hole depth and concrete thickness when drilling dust is left in the hole Drilled hole condition 2 illustratesthecorrespondingreductionwhendrilldustisremovedbyusingcompressedairHiltiTE-CDorTE-YDHollowDrillBitswithaHiltivacuum

Step 2 Check edge distance and anchor spacing

Tables 6 to 9 in this section show the minimum edge distance and anchor spacing based on a specific concrete thickness and whether or not the design is for cracked or uncracked concrete There are two cases of edge distance and anchor spacing combinations for each embedment and concrete condition (cracked or uncracked) Case 1 is the minimum edge distance needed for one anchor or for two anchors with large anchor spacing Case 2 is the minimum anchor spacing that can be used but the edge distance is increased to help prevent splitting Linear interpolation can be used between Case 1 and Case 2 for any specific concrete thickness and concrete condition See the following figure and calculation which can be used to deter-mine specific edge distance and anchor spacing combinations

Refer to tables 6 to 9 in this section for the minimum concrete thicknesses associated with the Hilti HIT-Z(-R) rods based on diameter and drilled hole condition

Figure 5

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 63

328

325

326

327

324

324

324

323

For a specific edge distance the permitted spacing is calculated as follows

(smin1 ndash smin2)sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

Table 6 - Minimum edge distance spacing and concrete thickness for 38-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 38

Effectiveembedment hef

in 2-38 3-38 4-12(mm) (60) (86) (114)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 4-58 5-34 4-58 5-58 6-38 5-34 6-34 7-38

(mm) (102) (117) (146) (117) (143) (162) (146) (171) (187)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 3-18 2-34 2-14 2-34 2-14 2 2-14 1-78 1-78(mm) (79) (70) (57) (70) (57) (51) (57) (48) (48)

s min1

in 9-18 7-34 6-18 7-34 6-12 5-58 6-18 5-38 4-12(mm) (232) (197) (156) (197) (165) (143) (156) (137) (114)

Minimum edge andspacingCase 2

c min2

in 5-58 4-34 3-34 4-34 3-78 3-14 3-34 3-18 2-34(mm) (143) (121) (95) (121) (98) (83) (95) (79) (70)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 2-18 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (54) (48) (48) (48) (48) (48) (48) (48) (48)

s min1

in 6-38 5-12 4-14 5-12 3-12 2-58 3-14 2 1-78(mm) (162) (140) (108) (140) (89) (67) (83) (51) (48)

Minimum edge andspacingCase 2

c min2

in 3-58 3-18 2-38 3-18 2-12 2-18 2-38 2 1-78(mm) (92) (79) (60) (79) (64) (54) (60) (51) (48)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Table 7 - Minimum edge distance spacing and concrete thickness for 12-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 12

Effectiveembedment hef

in 2-34 4-12 6(mm) (70) (114) (152)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 5 7-18 5-34 6-34 8-14 7-14 8-14 9-34

(mm) (102) (127) (181) (146) (171) (210) (184) (210) (248)

Unc

rack

ed C

oncr

ete Minimum edge and

spacingCase 1

c min1

in 5-18 4-18 2-78 3-58 3 2-12 2-78 2-12 2-12(mm) (130) (105) (73) (92) (76) (64) (73) (64) (64)

s min1

in 14-78 11-78 8-58 10-14 9 7-14 8-18 7-14 5(mm) (378) (302) (219) (260) (229) (184) (206) (184) (127)

Minimum edge andspacingCase 2

c min2

in 9-14 7-14 4-78 6-14 5-14 4-18 4-34 4-18 3-38(mm) (235) (184) (124) (159) (133) (105) (121) (105) (86)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

Cra

cked

Con

cret

e Minimum edge andspacingCase 1

c min1

in 3-58 3 2-12 2-58 2-12 2-12 2-12 2-12 2-12(mm) (92) (76) (64) (67) (64) (64) (64) (64) (64)

s min1

in 10-78 8-12 6 7-38 5-12 3-18 4-12 3-18 2-12(mm) (276) (216) (152) (187) (140) (79) (114) (79) (64)

Minimum edge andspacingCase 2

c min2

in 6-12 5 3-14 4-14 3-12 2-34 3-14 2-34 2-12(mm) (165) (127) (83) (108) (89) (70) (83) (70) (64)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Concrete Edge

Anchors not permitted in shaded area

Smin2

Smin1

Cm

in1

Cm

in2

Case 1

Case 2

cdesignedge distance c

caminatsge

sminatcgesdesign

spac

ing

s

Figure 6

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

64 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 8 - Minimum edge distance spacing and concrete thickness for 58-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 58

Effectiveembedment hef

in 3-34 5-58 7-12(mm) (95) (143) (191)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-12 7-34 9-38 7-38 9-58 10-12 9-14 11-12 12-14

(mm) (140) (197) (238) (187) (244) (267) (235) (292) (311)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 6-14 4-12 3-34 4-58 3-58 3-14 3-34 3-18 3-18(mm) (159) (114) (95) (117) (92) (83) (95) (79) (79)

s min1

in 18-38 12-78 10-58 13-78 10-38 9-34 10-78 8-38 7-38(mm) (467) (327) (270) (352) (264) (248) (276) (213) (187)

Minimum edge andspacingCase 2

c min2

in 11-38 7-34 6-14 8-14 6-18 5-12 6-38 4-78 4-58(mm) (289) (197) (159) (210) (156) (140) (162) (124) (117)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 4-58 3-38 3-18 3-12 3-18 3-18 3-18 3-18 3-18(mm) (117) (86) (79) (89) (79) (79) (79) (79) (79)

s min1

in 13-78 9-12 8-34 10-18 6-12 5-38 7-18 3-78 3-18(mm) (352) (241) (222) (257) (165) (137) (181) (98) (79)

Minimum edge andspacingCase 2

c min2

in 8-14 5-12 4-38 5-78 4-14 3-78 4-12 3-38 3-18(mm) (210) (140) (111) (149) (108) (98) (114) (86) (79)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Table 9 - Minimum edge distance spacing and concrete thickness for 34-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 34

Effectiveembedment hef

in 4 6-34 8-12(mm) (102) (171) (216)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-34 8 11-12 8-12 10-34 13-18 10-14 12-12 14-12

(mm) (146) (203) (292) (216) (273) (333) (260) (318) (368)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 9-34 7 5 6-58 5-14 4-14 5-12 4-12 4(mm) (248) (178) (127) (168) (133) (108) (140) (114) (102)

s min1

in 28-34 20-58 14 19-38 15-14 12-58 16 13-14 11(mm) (730) (524) (356) (492) (387) (321) (406) (337) (279)

Minimum edge andspacingCase 2

c min2

in 18-18 12-58 8-12 11-78 9-18 7-14 9-58 7-34 6-12(mm) (460) (321) (216) (302) (232) (184) (244) (197) (165)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 7-14 5-14 4-18 5 4 3-34 4-18 3-34 3-34(mm) (184) (133) (105) (127) (102) (95) (105) (95) (95)

s min1

in 21-34 15-12 12-14 14-12 11-38 9 12-18 8-34 6-12(mm) (552) (394) (311) (368) (289) (229) (308) (222) (165)

Minimum edge andspacingCase 2

c min2

in 13-14 9-14 6 8-58 6-58 5-18 7 5-12 4-12(mm) (337) (235) (152) (219) (168) (130) (178) (140) (114)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 4: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 61

328

325

326

327

324

324

324

323

Table 3 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in uncracked concrete 1234567810

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3610 4425 3075 3370 3890 4765(60) (127) (139) (161) (197) (137) (150) (173) (212)

3-38 4835 5300 5560 5560 10415 11410 13175 16135(86) (215) (236) (247) (247) (463) (508) (586) (718)

4-12 5560 5560 5560 5560 16035 17570 20285 24845(114) (247) (247) (247) (247) (713) (782) (902) (1105)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8190 8190 16035 17570 20285 24845(114) (331) (363) (364) (364) (713) (782) (902) (1105)

6 8190 8190 8190 8190 24690 27045 31230 38250(152) (364) (364) (364) (364) (1098) (1203) (1389) (1701)

58

3-34 5665 6205 7165 8775 12200 13365 15430 18900(95) (252) (276) (319) (390) (543) (595) (686) (841)

5-58 10405 11400 13165 14950 22415 24550 28350 34720(143) (463) (507) (586) (665) (997) (1092) (1261) (1544)7-12 14950 14950 14950 14950 34505 37800 43650 53455(191) (665) (665) (665) (665) (1535) (1681) (1942) (2378)

34

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)6-34 13680 14985 17305 19890 29460 32275 37265 45645(171) (609) (667) (770) (885) (1310) (1436) (1658) (2030)8-12 19330 19890 19890 19890 41635 45605 52660 64500(216) (860) (885) (885) (885) (1852) (2029) (2342) (2869)

Table 4 - HIT-HY 200 design strength with concretepullout failure for HIT-Z(-R) rods in cracked concrete 12345678910

Nominal anchor

diameter in

Effective embed in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2020 2215 2560 3135 2180 2385 2755 3375(60) (90) (99) (114) (139) (97) (106) (123) (150)

3-38 3425 3755 4335 5305 7380 8085 9335 11430(86) (152) (167) (193) (236) (328) (360) (415) (508)

4-12 5275 5560 5560 5560 11360 12445 14370 17600(114) (235) (247) (247) (247) (505) (554) (639) (783)

12

2-34 2520 2760 3185 3905 5425 5945 6865 8405(70) (112) (123) (142) (174) (241) (264) (305) (374)

4-12 5275 5780 6670 7640 11360 12445 14370 17600(114) (235) (257) (297) (340) (505) (554) (639) (783)

6 7640 7640 7640 7640 17490 19160 22120 27095(152) (340) (340) (340) (340) (778) (852) (984) (1205)

58

3-34 4010 4395 5075 6215 8640 9465 10930 13390(95) (178) (195) (226) (276) (384) (421) (486) (596)

5-58 7370 8075 9325 11420 15875 17390 20080 24595(143) (328) (359) (415) (508) (706) (774) (893) (1094)7-12 11350 12430 14355 14950 24440 26775 30915 37865(191) (505) (553) (639) (665) (1087) (1191) (1375) (1684)

34

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)6-34 9690 10615 12255 15010 20870 22860 26395 32330(171) (431) (472) (545) (668) (928) (1017) (1174) (1438)8-12 13690 15000 17320 19535 29490 32305 37300 45685(216) (609) (667) (770) (869) (1312) (1437) (1659) (2032)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 10 - 17 as necessary Compare to the steel values in table 5 The lesser of the values is to be used for

the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C)

FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby086 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long-term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry and water saturated concrete conditions7 Tabular values are for short-term loads only For sustained loads see section 31758 Tabularvaluesarefornormal-weightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors

38-indiameter-αseis = 0705 12-into34-indiameter-αseis = 075 See Section 3174 for additional information on seismic applications

10 Diamond core drilling with Hilti HIT-Z(-R) rods is permitted with no reduction in published data above

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

62 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 5 - Steel design strength for Hilti HIT-Z and HIT-Z-R rods 12

Nominal anchor diameter

in

ACI318AppendixDBasedDesignHIT-Z carbon steel rod HIT-Z-R stainless steel rod

Tensile3ϕNsalb (kN)

Shear4ϕVsalb (kN) αseisV

5Tensile3ϕNsa

lb (kN)Shear4ϕVsa

lb (kN) αseisV5

384750 1930

104750 2630

10(211) (86) (211) (117)

128695 3530

0658695 4815

075(387) (157) (387) (214)

5813850 5625

06513850 7670

065(616) (250) (616) (341)

3420455 8310

06520455 11330

065(910) (370) (910) (504)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Hilti HIT-Z(-R) rod permissible combinations of edge distance snchor spacing and concrete thicknessTheHiltiHIT-ZandHIT-Z-RRodsproducehigherexpansionforcesintheconcreteslabwhentheinstallationtorqueisappliedThis means that the anchor must be installed with larger edge distances and spacing when compared to standard threaded rod to minimize the likelihood that the concrete slab will split during installation

The permissible edge distance is based on the concrete condition (cracked or uncracked) the concrete thickness and anchor spacing if designing for anchor groups The permissible concrete thickness is dependent on whether or not the drill dust is removed during the anchor installation process

Step 1 Check concrete thickness

When using Hilti HIT-Z and HIT-Z-R rods drilling dust does not need to be removed for optimum capacity when base material temperatures are greater than 41deg F (5deg C) and a hammer drill with a carbide tipped drill bit is used However concrete thickness can be reduced if the drilling dust is removed The figure below shows both drilled hole conditions Drilled hole condition 1 illustrates the hole depth and concrete thickness when drilling dust is left in the hole Drilled hole condition 2 illustratesthecorrespondingreductionwhendrilldustisremovedbyusingcompressedairHiltiTE-CDorTE-YDHollowDrillBitswithaHiltivacuum

Step 2 Check edge distance and anchor spacing

Tables 6 to 9 in this section show the minimum edge distance and anchor spacing based on a specific concrete thickness and whether or not the design is for cracked or uncracked concrete There are two cases of edge distance and anchor spacing combinations for each embedment and concrete condition (cracked or uncracked) Case 1 is the minimum edge distance needed for one anchor or for two anchors with large anchor spacing Case 2 is the minimum anchor spacing that can be used but the edge distance is increased to help prevent splitting Linear interpolation can be used between Case 1 and Case 2 for any specific concrete thickness and concrete condition See the following figure and calculation which can be used to deter-mine specific edge distance and anchor spacing combinations

Refer to tables 6 to 9 in this section for the minimum concrete thicknesses associated with the Hilti HIT-Z(-R) rods based on diameter and drilled hole condition

Figure 5

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 63

328

325

326

327

324

324

324

323

For a specific edge distance the permitted spacing is calculated as follows

(smin1 ndash smin2)sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

Table 6 - Minimum edge distance spacing and concrete thickness for 38-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 38

Effectiveembedment hef

in 2-38 3-38 4-12(mm) (60) (86) (114)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 4-58 5-34 4-58 5-58 6-38 5-34 6-34 7-38

(mm) (102) (117) (146) (117) (143) (162) (146) (171) (187)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 3-18 2-34 2-14 2-34 2-14 2 2-14 1-78 1-78(mm) (79) (70) (57) (70) (57) (51) (57) (48) (48)

s min1

in 9-18 7-34 6-18 7-34 6-12 5-58 6-18 5-38 4-12(mm) (232) (197) (156) (197) (165) (143) (156) (137) (114)

Minimum edge andspacingCase 2

c min2

in 5-58 4-34 3-34 4-34 3-78 3-14 3-34 3-18 2-34(mm) (143) (121) (95) (121) (98) (83) (95) (79) (70)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 2-18 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (54) (48) (48) (48) (48) (48) (48) (48) (48)

s min1

in 6-38 5-12 4-14 5-12 3-12 2-58 3-14 2 1-78(mm) (162) (140) (108) (140) (89) (67) (83) (51) (48)

Minimum edge andspacingCase 2

c min2

in 3-58 3-18 2-38 3-18 2-12 2-18 2-38 2 1-78(mm) (92) (79) (60) (79) (64) (54) (60) (51) (48)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Table 7 - Minimum edge distance spacing and concrete thickness for 12-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 12

Effectiveembedment hef

in 2-34 4-12 6(mm) (70) (114) (152)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 5 7-18 5-34 6-34 8-14 7-14 8-14 9-34

(mm) (102) (127) (181) (146) (171) (210) (184) (210) (248)

Unc

rack

ed C

oncr

ete Minimum edge and

spacingCase 1

c min1

in 5-18 4-18 2-78 3-58 3 2-12 2-78 2-12 2-12(mm) (130) (105) (73) (92) (76) (64) (73) (64) (64)

s min1

in 14-78 11-78 8-58 10-14 9 7-14 8-18 7-14 5(mm) (378) (302) (219) (260) (229) (184) (206) (184) (127)

Minimum edge andspacingCase 2

c min2

in 9-14 7-14 4-78 6-14 5-14 4-18 4-34 4-18 3-38(mm) (235) (184) (124) (159) (133) (105) (121) (105) (86)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

Cra

cked

Con

cret

e Minimum edge andspacingCase 1

c min1

in 3-58 3 2-12 2-58 2-12 2-12 2-12 2-12 2-12(mm) (92) (76) (64) (67) (64) (64) (64) (64) (64)

s min1

in 10-78 8-12 6 7-38 5-12 3-18 4-12 3-18 2-12(mm) (276) (216) (152) (187) (140) (79) (114) (79) (64)

Minimum edge andspacingCase 2

c min2

in 6-12 5 3-14 4-14 3-12 2-34 3-14 2-34 2-12(mm) (165) (127) (83) (108) (89) (70) (83) (70) (64)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Concrete Edge

Anchors not permitted in shaded area

Smin2

Smin1

Cm

in1

Cm

in2

Case 1

Case 2

cdesignedge distance c

caminatsge

sminatcgesdesign

spac

ing

s

Figure 6

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

64 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 8 - Minimum edge distance spacing and concrete thickness for 58-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 58

Effectiveembedment hef

in 3-34 5-58 7-12(mm) (95) (143) (191)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-12 7-34 9-38 7-38 9-58 10-12 9-14 11-12 12-14

(mm) (140) (197) (238) (187) (244) (267) (235) (292) (311)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 6-14 4-12 3-34 4-58 3-58 3-14 3-34 3-18 3-18(mm) (159) (114) (95) (117) (92) (83) (95) (79) (79)

s min1

in 18-38 12-78 10-58 13-78 10-38 9-34 10-78 8-38 7-38(mm) (467) (327) (270) (352) (264) (248) (276) (213) (187)

Minimum edge andspacingCase 2

c min2

in 11-38 7-34 6-14 8-14 6-18 5-12 6-38 4-78 4-58(mm) (289) (197) (159) (210) (156) (140) (162) (124) (117)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 4-58 3-38 3-18 3-12 3-18 3-18 3-18 3-18 3-18(mm) (117) (86) (79) (89) (79) (79) (79) (79) (79)

s min1

in 13-78 9-12 8-34 10-18 6-12 5-38 7-18 3-78 3-18(mm) (352) (241) (222) (257) (165) (137) (181) (98) (79)

Minimum edge andspacingCase 2

c min2

in 8-14 5-12 4-38 5-78 4-14 3-78 4-12 3-38 3-18(mm) (210) (140) (111) (149) (108) (98) (114) (86) (79)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Table 9 - Minimum edge distance spacing and concrete thickness for 34-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 34

Effectiveembedment hef

in 4 6-34 8-12(mm) (102) (171) (216)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-34 8 11-12 8-12 10-34 13-18 10-14 12-12 14-12

(mm) (146) (203) (292) (216) (273) (333) (260) (318) (368)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 9-34 7 5 6-58 5-14 4-14 5-12 4-12 4(mm) (248) (178) (127) (168) (133) (108) (140) (114) (102)

s min1

in 28-34 20-58 14 19-38 15-14 12-58 16 13-14 11(mm) (730) (524) (356) (492) (387) (321) (406) (337) (279)

Minimum edge andspacingCase 2

c min2

in 18-18 12-58 8-12 11-78 9-18 7-14 9-58 7-34 6-12(mm) (460) (321) (216) (302) (232) (184) (244) (197) (165)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 7-14 5-14 4-18 5 4 3-34 4-18 3-34 3-34(mm) (184) (133) (105) (127) (102) (95) (105) (95) (95)

s min1

in 21-34 15-12 12-14 14-12 11-38 9 12-18 8-34 6-12(mm) (552) (394) (311) (368) (289) (229) (308) (222) (165)

Minimum edge andspacingCase 2

c min2

in 13-14 9-14 6 8-58 6-58 5-18 7 5-12 4-12(mm) (337) (235) (152) (219) (168) (130) (178) (140) (114)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 5: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

62 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 5 - Steel design strength for Hilti HIT-Z and HIT-Z-R rods 12

Nominal anchor diameter

in

ACI318AppendixDBasedDesignHIT-Z carbon steel rod HIT-Z-R stainless steel rod

Tensile3ϕNsalb (kN)

Shear4ϕVsalb (kN) αseisV

5Tensile3ϕNsa

lb (kN)Shear4ϕVsa

lb (kN) αseisV5

384750 1930

104750 2630

10(211) (86) (211) (117)

128695 3530

0658695 4815

075(387) (157) (387) (214)

5813850 5625

06513850 7670

065(616) (250) (616) (341)

3420455 8310

06520455 11330

065(910) (370) (910) (504)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Hilti HIT-Z(-R) rod permissible combinations of edge distance snchor spacing and concrete thicknessTheHiltiHIT-ZandHIT-Z-RRodsproducehigherexpansionforcesintheconcreteslabwhentheinstallationtorqueisappliedThis means that the anchor must be installed with larger edge distances and spacing when compared to standard threaded rod to minimize the likelihood that the concrete slab will split during installation

The permissible edge distance is based on the concrete condition (cracked or uncracked) the concrete thickness and anchor spacing if designing for anchor groups The permissible concrete thickness is dependent on whether or not the drill dust is removed during the anchor installation process

Step 1 Check concrete thickness

When using Hilti HIT-Z and HIT-Z-R rods drilling dust does not need to be removed for optimum capacity when base material temperatures are greater than 41deg F (5deg C) and a hammer drill with a carbide tipped drill bit is used However concrete thickness can be reduced if the drilling dust is removed The figure below shows both drilled hole conditions Drilled hole condition 1 illustrates the hole depth and concrete thickness when drilling dust is left in the hole Drilled hole condition 2 illustratesthecorrespondingreductionwhendrilldustisremovedbyusingcompressedairHiltiTE-CDorTE-YDHollowDrillBitswithaHiltivacuum

Step 2 Check edge distance and anchor spacing

Tables 6 to 9 in this section show the minimum edge distance and anchor spacing based on a specific concrete thickness and whether or not the design is for cracked or uncracked concrete There are two cases of edge distance and anchor spacing combinations for each embedment and concrete condition (cracked or uncracked) Case 1 is the minimum edge distance needed for one anchor or for two anchors with large anchor spacing Case 2 is the minimum anchor spacing that can be used but the edge distance is increased to help prevent splitting Linear interpolation can be used between Case 1 and Case 2 for any specific concrete thickness and concrete condition See the following figure and calculation which can be used to deter-mine specific edge distance and anchor spacing combinations

Refer to tables 6 to 9 in this section for the minimum concrete thicknesses associated with the Hilti HIT-Z(-R) rods based on diameter and drilled hole condition

Figure 5

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 63

328

325

326

327

324

324

324

323

For a specific edge distance the permitted spacing is calculated as follows

(smin1 ndash smin2)sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

Table 6 - Minimum edge distance spacing and concrete thickness for 38-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 38

Effectiveembedment hef

in 2-38 3-38 4-12(mm) (60) (86) (114)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 4-58 5-34 4-58 5-58 6-38 5-34 6-34 7-38

(mm) (102) (117) (146) (117) (143) (162) (146) (171) (187)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 3-18 2-34 2-14 2-34 2-14 2 2-14 1-78 1-78(mm) (79) (70) (57) (70) (57) (51) (57) (48) (48)

s min1

in 9-18 7-34 6-18 7-34 6-12 5-58 6-18 5-38 4-12(mm) (232) (197) (156) (197) (165) (143) (156) (137) (114)

Minimum edge andspacingCase 2

c min2

in 5-58 4-34 3-34 4-34 3-78 3-14 3-34 3-18 2-34(mm) (143) (121) (95) (121) (98) (83) (95) (79) (70)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 2-18 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (54) (48) (48) (48) (48) (48) (48) (48) (48)

s min1

in 6-38 5-12 4-14 5-12 3-12 2-58 3-14 2 1-78(mm) (162) (140) (108) (140) (89) (67) (83) (51) (48)

Minimum edge andspacingCase 2

c min2

in 3-58 3-18 2-38 3-18 2-12 2-18 2-38 2 1-78(mm) (92) (79) (60) (79) (64) (54) (60) (51) (48)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Table 7 - Minimum edge distance spacing and concrete thickness for 12-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 12

Effectiveembedment hef

in 2-34 4-12 6(mm) (70) (114) (152)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 5 7-18 5-34 6-34 8-14 7-14 8-14 9-34

(mm) (102) (127) (181) (146) (171) (210) (184) (210) (248)

Unc

rack

ed C

oncr

ete Minimum edge and

spacingCase 1

c min1

in 5-18 4-18 2-78 3-58 3 2-12 2-78 2-12 2-12(mm) (130) (105) (73) (92) (76) (64) (73) (64) (64)

s min1

in 14-78 11-78 8-58 10-14 9 7-14 8-18 7-14 5(mm) (378) (302) (219) (260) (229) (184) (206) (184) (127)

Minimum edge andspacingCase 2

c min2

in 9-14 7-14 4-78 6-14 5-14 4-18 4-34 4-18 3-38(mm) (235) (184) (124) (159) (133) (105) (121) (105) (86)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

Cra

cked

Con

cret

e Minimum edge andspacingCase 1

c min1

in 3-58 3 2-12 2-58 2-12 2-12 2-12 2-12 2-12(mm) (92) (76) (64) (67) (64) (64) (64) (64) (64)

s min1

in 10-78 8-12 6 7-38 5-12 3-18 4-12 3-18 2-12(mm) (276) (216) (152) (187) (140) (79) (114) (79) (64)

Minimum edge andspacingCase 2

c min2

in 6-12 5 3-14 4-14 3-12 2-34 3-14 2-34 2-12(mm) (165) (127) (83) (108) (89) (70) (83) (70) (64)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Concrete Edge

Anchors not permitted in shaded area

Smin2

Smin1

Cm

in1

Cm

in2

Case 1

Case 2

cdesignedge distance c

caminatsge

sminatcgesdesign

spac

ing

s

Figure 6

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

64 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 8 - Minimum edge distance spacing and concrete thickness for 58-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 58

Effectiveembedment hef

in 3-34 5-58 7-12(mm) (95) (143) (191)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-12 7-34 9-38 7-38 9-58 10-12 9-14 11-12 12-14

(mm) (140) (197) (238) (187) (244) (267) (235) (292) (311)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 6-14 4-12 3-34 4-58 3-58 3-14 3-34 3-18 3-18(mm) (159) (114) (95) (117) (92) (83) (95) (79) (79)

s min1

in 18-38 12-78 10-58 13-78 10-38 9-34 10-78 8-38 7-38(mm) (467) (327) (270) (352) (264) (248) (276) (213) (187)

Minimum edge andspacingCase 2

c min2

in 11-38 7-34 6-14 8-14 6-18 5-12 6-38 4-78 4-58(mm) (289) (197) (159) (210) (156) (140) (162) (124) (117)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 4-58 3-38 3-18 3-12 3-18 3-18 3-18 3-18 3-18(mm) (117) (86) (79) (89) (79) (79) (79) (79) (79)

s min1

in 13-78 9-12 8-34 10-18 6-12 5-38 7-18 3-78 3-18(mm) (352) (241) (222) (257) (165) (137) (181) (98) (79)

Minimum edge andspacingCase 2

c min2

in 8-14 5-12 4-38 5-78 4-14 3-78 4-12 3-38 3-18(mm) (210) (140) (111) (149) (108) (98) (114) (86) (79)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Table 9 - Minimum edge distance spacing and concrete thickness for 34-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 34

Effectiveembedment hef

in 4 6-34 8-12(mm) (102) (171) (216)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-34 8 11-12 8-12 10-34 13-18 10-14 12-12 14-12

(mm) (146) (203) (292) (216) (273) (333) (260) (318) (368)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 9-34 7 5 6-58 5-14 4-14 5-12 4-12 4(mm) (248) (178) (127) (168) (133) (108) (140) (114) (102)

s min1

in 28-34 20-58 14 19-38 15-14 12-58 16 13-14 11(mm) (730) (524) (356) (492) (387) (321) (406) (337) (279)

Minimum edge andspacingCase 2

c min2

in 18-18 12-58 8-12 11-78 9-18 7-14 9-58 7-34 6-12(mm) (460) (321) (216) (302) (232) (184) (244) (197) (165)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 7-14 5-14 4-18 5 4 3-34 4-18 3-34 3-34(mm) (184) (133) (105) (127) (102) (95) (105) (95) (95)

s min1

in 21-34 15-12 12-14 14-12 11-38 9 12-18 8-34 6-12(mm) (552) (394) (311) (368) (289) (229) (308) (222) (165)

Minimum edge andspacingCase 2

c min2

in 13-14 9-14 6 8-58 6-58 5-18 7 5-12 4-12(mm) (337) (235) (152) (219) (168) (130) (178) (140) (114)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 6: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 63

328

325

326

327

324

324

324

323

For a specific edge distance the permitted spacing is calculated as follows

(smin1 ndash smin2)sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

Table 6 - Minimum edge distance spacing and concrete thickness for 38-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 38

Effectiveembedment hef

in 2-38 3-38 4-12(mm) (60) (86) (114)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 4-58 5-34 4-58 5-58 6-38 5-34 6-34 7-38

(mm) (102) (117) (146) (117) (143) (162) (146) (171) (187)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 3-18 2-34 2-14 2-34 2-14 2 2-14 1-78 1-78(mm) (79) (70) (57) (70) (57) (51) (57) (48) (48)

s min1

in 9-18 7-34 6-18 7-34 6-12 5-58 6-18 5-38 4-12(mm) (232) (197) (156) (197) (165) (143) (156) (137) (114)

Minimum edge andspacingCase 2

c min2

in 5-58 4-34 3-34 4-34 3-78 3-14 3-34 3-18 2-34(mm) (143) (121) (95) (121) (98) (83) (95) (79) (70)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 2-18 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (54) (48) (48) (48) (48) (48) (48) (48) (48)

s min1

in 6-38 5-12 4-14 5-12 3-12 2-58 3-14 2 1-78(mm) (162) (140) (108) (140) (89) (67) (83) (51) (48)

Minimum edge andspacingCase 2

c min2

in 3-58 3-18 2-38 3-18 2-12 2-18 2-38 2 1-78(mm) (92) (79) (60) (79) (64) (54) (60) (51) (48)

s min2

in 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78 1-78(mm) (48) (48) (48) (48) (48) (48) (48) (48) (48)

Table 7 - Minimum edge distance spacing and concrete thickness for 12-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 12

Effectiveembedment hef

in 2-34 4-12 6(mm) (70) (114) (152)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 4 5 7-18 5-34 6-34 8-14 7-14 8-14 9-34

(mm) (102) (127) (181) (146) (171) (210) (184) (210) (248)

Unc

rack

ed C

oncr

ete Minimum edge and

spacingCase 1

c min1

in 5-18 4-18 2-78 3-58 3 2-12 2-78 2-12 2-12(mm) (130) (105) (73) (92) (76) (64) (73) (64) (64)

s min1

in 14-78 11-78 8-58 10-14 9 7-14 8-18 7-14 5(mm) (378) (302) (219) (260) (229) (184) (206) (184) (127)

Minimum edge andspacingCase 2

c min2

in 9-14 7-14 4-78 6-14 5-14 4-18 4-34 4-18 3-38(mm) (235) (184) (124) (159) (133) (105) (121) (105) (86)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

Cra

cked

Con

cret

e Minimum edge andspacingCase 1

c min1

in 3-58 3 2-12 2-58 2-12 2-12 2-12 2-12 2-12(mm) (92) (76) (64) (67) (64) (64) (64) (64) (64)

s min1

in 10-78 8-12 6 7-38 5-12 3-18 4-12 3-18 2-12(mm) (276) (216) (152) (187) (140) (79) (114) (79) (64)

Minimum edge andspacingCase 2

c min2

in 6-12 5 3-14 4-14 3-12 2-34 3-14 2-34 2-12(mm) (165) (127) (83) (108) (89) (70) (83) (70) (64)

s min2

in 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12 2-12(mm) (64) (64) (64) (64) (64) (64) (64) (64) (64)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Concrete Edge

Anchors not permitted in shaded area

Smin2

Smin1

Cm

in1

Cm

in2

Case 1

Case 2

cdesignedge distance c

caminatsge

sminatcgesdesign

spac

ing

s

Figure 6

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

64 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 8 - Minimum edge distance spacing and concrete thickness for 58-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 58

Effectiveembedment hef

in 3-34 5-58 7-12(mm) (95) (143) (191)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-12 7-34 9-38 7-38 9-58 10-12 9-14 11-12 12-14

(mm) (140) (197) (238) (187) (244) (267) (235) (292) (311)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 6-14 4-12 3-34 4-58 3-58 3-14 3-34 3-18 3-18(mm) (159) (114) (95) (117) (92) (83) (95) (79) (79)

s min1

in 18-38 12-78 10-58 13-78 10-38 9-34 10-78 8-38 7-38(mm) (467) (327) (270) (352) (264) (248) (276) (213) (187)

Minimum edge andspacingCase 2

c min2

in 11-38 7-34 6-14 8-14 6-18 5-12 6-38 4-78 4-58(mm) (289) (197) (159) (210) (156) (140) (162) (124) (117)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 4-58 3-38 3-18 3-12 3-18 3-18 3-18 3-18 3-18(mm) (117) (86) (79) (89) (79) (79) (79) (79) (79)

s min1

in 13-78 9-12 8-34 10-18 6-12 5-38 7-18 3-78 3-18(mm) (352) (241) (222) (257) (165) (137) (181) (98) (79)

Minimum edge andspacingCase 2

c min2

in 8-14 5-12 4-38 5-78 4-14 3-78 4-12 3-38 3-18(mm) (210) (140) (111) (149) (108) (98) (114) (86) (79)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Table 9 - Minimum edge distance spacing and concrete thickness for 34-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 34

Effectiveembedment hef

in 4 6-34 8-12(mm) (102) (171) (216)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-34 8 11-12 8-12 10-34 13-18 10-14 12-12 14-12

(mm) (146) (203) (292) (216) (273) (333) (260) (318) (368)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 9-34 7 5 6-58 5-14 4-14 5-12 4-12 4(mm) (248) (178) (127) (168) (133) (108) (140) (114) (102)

s min1

in 28-34 20-58 14 19-38 15-14 12-58 16 13-14 11(mm) (730) (524) (356) (492) (387) (321) (406) (337) (279)

Minimum edge andspacingCase 2

c min2

in 18-18 12-58 8-12 11-78 9-18 7-14 9-58 7-34 6-12(mm) (460) (321) (216) (302) (232) (184) (244) (197) (165)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 7-14 5-14 4-18 5 4 3-34 4-18 3-34 3-34(mm) (184) (133) (105) (127) (102) (95) (105) (95) (95)

s min1

in 21-34 15-12 12-14 14-12 11-38 9 12-18 8-34 6-12(mm) (552) (394) (311) (368) (289) (229) (308) (222) (165)

Minimum edge andspacingCase 2

c min2

in 13-14 9-14 6 8-58 6-58 5-18 7 5-12 4-12(mm) (337) (235) (152) (219) (168) (130) (178) (140) (114)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 7: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

64 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 8 - Minimum edge distance spacing and concrete thickness for 58-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 58

Effectiveembedment hef

in 3-34 5-58 7-12(mm) (95) (143) (191)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-12 7-34 9-38 7-38 9-58 10-12 9-14 11-12 12-14

(mm) (140) (197) (238) (187) (244) (267) (235) (292) (311)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 6-14 4-12 3-34 4-58 3-58 3-14 3-34 3-18 3-18(mm) (159) (114) (95) (117) (92) (83) (95) (79) (79)

s min1

in 18-38 12-78 10-58 13-78 10-38 9-34 10-78 8-38 7-38(mm) (467) (327) (270) (352) (264) (248) (276) (213) (187)

Minimum edge andspacingCase 2

c min2

in 11-38 7-34 6-14 8-14 6-18 5-12 6-38 4-78 4-58(mm) (289) (197) (159) (210) (156) (140) (162) (124) (117)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 4-58 3-38 3-18 3-12 3-18 3-18 3-18 3-18 3-18(mm) (117) (86) (79) (89) (79) (79) (79) (79) (79)

s min1

in 13-78 9-12 8-34 10-18 6-12 5-38 7-18 3-78 3-18(mm) (352) (241) (222) (257) (165) (137) (181) (98) (79)

Minimum edge andspacingCase 2

c min2

in 8-14 5-12 4-38 5-78 4-14 3-78 4-12 3-38 3-18(mm) (210) (140) (111) (149) (108) (98) (114) (86) (79)

s min2

in 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18 3-18(mm) (79) (79) (79) (79) (79) (79) (79) (79) (79)

Table 9 - Minimum edge distance spacing and concrete thickness for 34-in diameter Hilti HIT-Z and HIT-Z-R rods1

Nominal anchor diameter d in 34

Effectiveembedment hef

in 4 6-34 8-12(mm) (102) (171) (216)

Drilled hole condition - - 2 2 1 or 2 2 2 1 or 2 2 2 1 or 2

Minimum concrete thickness hin 5-34 8 11-12 8-12 10-34 13-18 10-14 12-12 14-12

(mm) (146) (203) (292) (216) (273) (333) (260) (318) (368)

Unc

rack

ed c

oncr

ete Minimum edge and

spacingCase 1

c min1

in 9-34 7 5 6-58 5-14 4-14 5-12 4-12 4(mm) (248) (178) (127) (168) (133) (108) (140) (114) (102)

s min1

in 28-34 20-58 14 19-38 15-14 12-58 16 13-14 11(mm) (730) (524) (356) (492) (387) (321) (406) (337) (279)

Minimum edge andspacingCase 2

c min2

in 18-18 12-58 8-12 11-78 9-18 7-14 9-58 7-34 6-12(mm) (460) (321) (216) (302) (232) (184) (244) (197) (165)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

Cra

cked

con

cret

e Minimum edge andspacingCase 1

c min1

in 7-14 5-14 4-18 5 4 3-34 4-18 3-34 3-34(mm) (184) (133) (105) (127) (102) (95) (105) (95) (95)

s min1

in 21-34 15-12 12-14 14-12 11-38 9 12-18 8-34 6-12(mm) (552) (394) (311) (368) (289) (229) (308) (222) (165)

Minimum edge andspacingCase 2

c min2

in 13-14 9-14 6 8-58 6-58 5-18 7 5-12 4-12(mm) (337) (235) (152) (219) (168) (130) (178) (140) (114)

s min2

in 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34(mm) (95) (95) (95) (95) (95) (95) (95) (95) (95)

1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2 Linearinterpoloationforaspecificedgedistancecwherecmin1 lt c lt cmin2 will determine the permissible spacing s as follows

(smin1 ndash smin2) sgesmin2 + ____________ (c ndash cmin2) (cmin1 ndash cmin2)

2 For shaded cells drilling dust must be removed from drilled hole to justify minimum concrete thickness

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 8: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 65

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 6 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 10 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

38-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na na 021 057 053 052 na na 005 na na 010 na na na

2 (51) 064 060 057 na 025 021 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 038 026 022 058 054 053 033 010 007 038 021 013 na na na

3 (76) 071 065 061 046 030 025 061 055 054 051 016 010 051 032 021 na na na4 (102) 078 070 065 059 036 029 064 057 055 079 024 016 079 044 029 076 na na

4-58 (117) 082 073 067 069 040 031 066 058 056 098 030 020 098 049 031 081 055 na5 (127) 085 075 069 074 043 033 068 058 056 100 034 022 100 052 033 084 057 na

5-34 (146) 090 078 071 086 049 036 070 059 057 100 042 027 100 059 036 091 061 0536 (152) 092 080 072 089 051 038 071 060 057 100 045 029 100 062 038 092 063 0547 (178) 099 085 076 100 060 043 075 061 059 057 037 072 043 100 068 0588 (203) 100 090 080 069 049 079 063 060 069 045 083 049 100 072 0639 (229) 100 094 083 077 055 082 065 061 083 054 093 055 077 06610 (254) 100 099 087 086 061 086 066 062 097 063 100 063 081 07011 (279) 100 091 094 067 089 068 063 100 072 072 085 07312 (305) 094 100 073 093 070 065 083 083 088 07714 (356) 100 085 100 073 067 100 100 096 08316 (406) 098 076 070 100 08818 (457) 100 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Table 11 - Load adjustment factors for 38-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

38-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12 2-38 3-38 4-12(mm) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114) (60) (86) (114)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-78 (48) 063 059 057 na 056 050 057 053 052 na 008 005 na 016 010 na na na

2 (51) 064 060 057 na 057 051 057 053 052 na 009 006 na 017 011 na na na2-14 (57) 066 061 058 073 060 053 058 054 053 034 010 007 067 021 014 na na na

3 (76) 071 065 061 088 070 060 061 055 054 052 016 010 088 032 021 na na na4 (102) 078 070 065 100 084 070 064 057 055 080 025 016 100 049 032 076 na na

4-58 (117) 082 073 067 093 076 067 058 056 099 031 020 061 040 081 055 na5 (127) 085 075 069 099 080 068 058 056 100 034 022 069 045 085 057 na

5-34 (146) 090 078 071 100 088 071 059 057 042 028 085 055 091 061 0536 (152) 092 080 072 091 071 060 057 045 029 091 059 093 063 0547 (178) 099 085 076 100 075 061 059 057 037 100 074 100 068 0598 (203) 100 090 080 079 063 060 070 045 091 072 0639 (229) 094 083 082 065 061 083 054 100 077 06710 (254) 099 087 086 066 062 097 063 081 07011 (279) 100 091 089 068 064 100 073 085 07412 (305) 094 093 070 065 083 089 07714 (356) 100 100 073 067 100 096 08316 (406) 076 070 100 08918 (457) 079 072 09424 (610) 089 079 10030 (762) 099 08736 (914) 100 094

gt 48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 9: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

66 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 7 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 12 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

12-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 na 023 020 055 053 053 na 009 006 na 018 012 na na na

2-78 (73) 067 061 058 035 024 021 056 054 053 022 011 007 035 022 015 na na na3 (76) 068 061 058 036 025 021 056 054 053 023 012 008 036 024 015 na na na

3-12 (89) 071 063 060 040 027 022 057 055 054 029 015 010 040 030 019 na na na4 (102) 074 065 061 044 029 024 058 055 054 036 018 012 044 033 024 058 na na

4-12 (114) 077 067 063 050 031 025 059 056 055 042 022 014 050 035 025 061 na na5 (127) 080 069 064 055 033 027 060 057 055 050 026 017 055 038 027 065 na na

5-12 (140) 083 070 065 061 035 028 062 057 056 057 030 019 061 040 028 068 na na6 (152) 086 072 067 066 038 030 063 058 056 065 034 022 066 043 030 071 057 na7 (178) 092 076 069 077 043 033 065 059 057 082 042 028 082 049 033 077 061 na

7-14 (184) 094 077 070 080 044 034 065 060 057 087 045 029 087 050 034 078 062 0548 (203) 098 080 072 088 049 036 067 061 058 100 052 034 100 056 036 082 066 0579 (229) 100 083 075 099 055 040 069 062 059 100 062 040 100 063 040 087 070 06010 (254) 100 087 078 100 061 044 071 063 060 100 072 047 100 072 047 092 073 06411 (279) 100 091 081 067 048 073 065 061 084 054 084 054 096 077 06712 (305) 100 094 083 073 053 075 066 062 095 062 095 062 100 080 07014 (356) 100 100 089 085 062 079 069 064 100 078 100 078 087 07516 (406) 100 094 098 070 083 072 066 095 095 093 08018 (457) 100 100 079 088 074 068 100 100 098 08524 (610) 100 100 082 074 100 09830 (762) 090 080 10036 (914) 098 086

gt 48 (1219) 100 098

Table 13 - Load adjustment factors for 12-in diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 12

12-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6 2-34 4-12 6(mm) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152) (70) (114) (152)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 2-12 (64) 065 059 057 071 056 050 055 053 053 018 009 006 035 018 012 na na na

2-78 (73) 067 061 058 077 059 053 056 054 053 022 011 007 044 023 015 na na na3 (76) 068 061 058 079 060 053 056 054 053 023 012 008 047 024 016 na na na

3-12 (89) 071 063 060 088 065 057 057 055 054 029 015 010 059 030 020 na na na4 (102) 074 065 061 098 070 060 058 055 054 036 018 012 072 037 024 058 na na

4-12 (114) 077 067 063 100 075 064 059 056 055 043 022 014 086 044 029 062 na na5 (127) 080 069 064 100 080 067 061 057 055 050 026 017 100 052 034 065 na na

5-12 (140) 083 070 065 100 086 071 062 057 056 058 030 019 100 060 039 068 na na6 (152) 086 072 067 100 091 075 063 058 056 066 034 022 100 068 044 071 057 na7 (178) 092 076 069 100 100 083 065 059 057 083 043 028 100 086 056 077 062 na

7-14 (184) 094 077 070 085 065 060 057 088 045 029 090 059 078 063 0548 (203) 098 080 072 091 067 061 058 100 052 034 100 068 082 066 0579 (229) 100 083 075 100 069 062 059 062 041 081 087 070 06010 (254) 100 087 078 071 064 060 073 047 095 092 074 06411 (279) 100 091 081 073 065 061 084 055 100 096 077 06712 (305) 094 083 075 066 062 096 062 100 081 07014 (356) 100 089 079 069 064 100 079 087 07516 (406) 094 084 072 066 096 093 08118 (457) 100 088 074 068 100 099 08524 (610) 100 082 074 100 09930 (762) 091 080 10036 (914) 099 087

gt 48 (1219) 100 099

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 10: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 67

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 8 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 14 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

58-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 na na 020 055 054 053 na na 007 na na 013 na na na

3-14 (83) 064 060 057 na 024 020 055 054 053 na 011 007 na 021 014 na na na3-34 (95) 067 061 058 034 025 021 056 054 053 023 013 009 034 027 017 na na na

4 (102) 068 062 059 036 026 022 057 055 053 025 015 010 036 029 019 na na na5 (127) 072 065 061 042 029 024 058 056 054 036 021 013 042 038 024 na na na

5-12 (140) 074 066 062 045 031 025 059 056 055 041 024 015 045 040 025 061 na na6 (152) 077 068 063 049 033 026 060 057 055 047 027 018 049 042 026 063 na na7 (178) 081 071 066 057 036 029 062 058 056 059 034 022 059 047 029 068 na na

7-38 (187) 083 072 066 060 038 030 062 059 056 064 037 024 064 049 030 070 058 na8 (203) 086 074 068 065 040 031 063 059 057 072 041 027 072 052 031 073 061 na9 (229) 090 077 070 073 045 034 065 060 058 086 050 032 086 058 034 078 065 na

9-14 (235) 091 077 071 076 046 035 065 061 058 089 052 034 089 059 035 079 065 05710 (254) 094 080 072 082 050 037 067 062 059 100 058 038 100 064 038 082 068 05911 (279) 099 083 074 090 055 039 068 063 060 100 067 043 100 070 043 086 071 06212 (305) 100 086 077 098 060 043 070 064 060 100 076 050 100 077 050 090 075 06514 (356) 100 091 081 100 070 050 073 066 062 096 062 096 062 097 081 07016 (406) 100 097 086 080 057 077 069 064 100 076 100 076 100 086 07518 (457) 100 100 090 089 064 080 071 066 091 091 091 07924 (610) 100 100 100 086 090 078 071 100 100 100 09130 (762) 100 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Table 15 - Load adjustment factors for 58-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

58-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12 3-34 5-58 7-12(mm) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191) (95) (143) (191)

Spacing(s)Edg

eDistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-18 (79) 064 059 057 067 056 050 055 054 053 018 010 007 035 020 013 na na na

3-14 (83) 064 060 057 069 056 051 055 054 053 019 011 007 038 022 014 na na na3-34 (95) 067 061 058 075 060 053 056 054 053 023 013 009 047 027 017 na na na

4 (102) 068 062 059 078 062 055 057 055 053 026 015 010 051 030 019 na na na5 (127) 072 065 061 091 070 060 058 056 054 036 021 013 072 041 027 na na na

5-12 (140) 074 066 062 098 074 063 059 056 055 041 024 015 083 048 031 061 na na6 (152) 077 068 063 100 078 066 060 057 055 047 027 018 094 054 035 064 na na7 (178) 081 071 066 100 087 072 062 058 056 059 034 022 100 068 044 069 na na

7-38 (187) 083 072 066 100 090 074 062 059 056 064 037 024 100 074 048 070 059 na8 (203) 086 074 068 100 096 078 063 059 057 073 042 027 100 084 054 073 061 na9 (229) 090 077 070 100 100 085 065 060 058 087 050 032 100 100 065 078 065 na

9-14 (235) 091 077 071 086 066 061 058 090 052 034 068 079 066 05710 (254) 094 080 072 091 067 062 059 100 058 038 076 082 068 05911 (279) 099 083 074 098 069 063 060 067 044 088 086 072 06212 (305) 100 086 077 100 070 064 060 077 050 100 090 075 06514 (356) 100 091 081 074 066 062 097 063 100 097 081 07016 (406) 097 086 077 069 064 100 077 100 086 07518 (457) 100 090 080 071 066 092 092 07924 (610) 100 090 078 071 100 100 09230 (762) 100 085 076 10036 (914) 092 081

gt 48 (1219) 100 092

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 11: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

68 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD3 Spacing reduction factor in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒhV = 10

If a reduction factor value is in a shaded area this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa) Check with figure 6 and table 9 of this section to calculate permissible edge distance spacing and concrete thickness combinations

Table 16 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in uncracked concrete 12

34-in HIT-Z(-R)uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na na na 056 054 053 na na na na na na na na na

4 (102) 067 060 058 na na 021 057 054 053 na na 008 na na 017 na na na4-18 (105) 067 060 058 na na 021 057 054 053 na na 009 na na 018 na na na4-14 (108) 068 060 058 na 024 021 057 054 053 na 013 009 na 026 019 na na na

5 (127) 071 062 060 039 026 023 058 055 054 035 017 012 039 032 023 na na na5-34 (146) 074 064 061 044 028 024 059 056 055 043 021 015 044 034 024 061 na na

6 (152) 075 065 062 045 028 024 060 056 055 045 022 016 045 035 024 063 na na7 (178) 079 067 064 053 031 027 061 057 056 057 028 020 057 038 027 068 na na8 (203) 083 070 066 060 034 029 063 058 056 070 034 024 070 042 029 072 na na

8-12 (216) 085 071 067 064 036 030 064 059 057 077 037 026 077 044 030 075 059 na9 (229) 088 072 068 068 037 031 065 059 057 083 040 029 083 045 031 077 060 na10 (254) 092 075 070 075 040 033 066 060 058 098 047 033 098 049 033 081 064 na

10-14 (260) 093 075 070 077 041 034 067 060 058 100 049 035 100 050 035 082 064 05711 (279) 096 077 072 083 044 035 068 061 059 100 055 039 100 055 039 085 067 05912 (305) 100 080 074 090 048 038 070 062 060 100 062 044 100 062 044 089 070 06214 (356) 100 085 077 100 056 043 073 064 061 100 078 055 100 078 055 096 075 06716 (406) 100 090 081 100 064 050 076 066 063 100 096 068 100 096 068 100 080 07218 (457) 100 094 085 100 072 056 080 068 064 100 100 081 100 100 081 085 07624 (610) 100 100 097 100 097 075 089 074 069 100 100 100 100 099 08830 (762) 100 100 100 093 099 080 074 100 09836 (914) 100 100 086 079 100

gt 48 (1219) 099 089

Table 17 - Load adjustment factors for 34-in diameter HIT-Z and HIT-Z-R rods in cracked concrete 12

34-in HIT-Z(-R)cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear3

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12 4 6-34 8-12(mm) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216) (102) (171) (216)

Sp

acin

g (s

) E

dge

dis

tanc

e (c

a)

Con

cret

e th

ickn

ess

(h)

- in

(m

m) 3-34 (95) 066 059 057 na 056 051 056 054 053 na 011 008 na 022 016 na na na

4 (102) 067 060 058 na 057 052 057 054 053 na 012 009 na 024 017 na na na4-18 (105) 067 060 058 076 058 053 057 054 053 026 013 009 052 025 018 na na na4-14 (108) 068 060 058 078 059 053 057 054 053 027 013 009 055 026 019 na na na

5 (127) 071 062 060 087 063 057 058 055 054 035 017 012 070 034 024 na na na5-34 (146) 074 064 061 097 068 061 059 056 055 043 021 015 086 042 029 062 na na

6 (152) 075 065 062 100 070 062 060 056 055 046 022 016 092 044 031 063 na na7 (178) 079 067 064 100 077 067 062 057 056 058 028 020 100 056 040 068 na na8 (203) 083 070 066 100 084 072 063 058 056 070 034 024 100 068 048 073 na na

8-12 (216) 085 071 067 100 088 075 064 059 057 077 037 026 100 075 053 075 059 na9 (229) 088 072 068 100 091 078 065 059 057 084 041 029 100 082 058 077 061 na10 (254) 092 075 070 100 099 083 067 060 058 099 048 034 100 095 068 081 064 na

10-14 (260) 093 075 070 100 100 085 067 060 058 100 050 035 100 099 070 082 065 05811 (279) 096 077 072 100 089 068 061 059 100 055 039 100 100 078 085 067 06012 (305) 100 080 074 100 095 070 062 060 100 063 044 100 089 089 070 06214 (356) 100 085 077 100 100 073 064 061 100 079 056 100 100 096 076 06716 (406) 100 090 081 076 066 063 097 068 100 081 07218 (457) 100 094 085 080 068 065 100 082 086 07624 (610) 100 100 097 090 074 069 100 099 08830 (762) 100 100 081 074 100 09836 (914) 100 087 079 100

gt48 (1219) 099 089

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 12: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 69

328

325

326

327

324

324

324

323

32332 Hilti HIT-HY 200 Adhesive with deformed reinforcing bars (rebar)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water-saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 7 - Rebar installation conditions

Setting information Symbol UnitsRebar size

3 4 5 6 7 8 9 10Nominal bit diameter do in 12 58 34 78 1 1-18 1-38 1-12

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 10-18 11-14(mm) (86) (114) (143) (171) (200) (229) (257) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 4-12 5(mm) (60) (70) (79) (89) (89) (102) (114) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 22-12 25(mm) (191) (254) (318) (381) (445) (508) (572) (635)

Minimum concrete member thickness hmin

in hef + 1-14hef + 2do(mm) hef + 30

Table 18 - Rebar installed with HIT-HY 200 adhesive

Figure 8 - Rebar installed with HIT-HY 200 adhesive

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 13: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

70 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 19 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in uncracked concrete 12345678

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 4295 4295 4295 4550 9245 9245 9245 9800(86) (191) (191) (191) (202) (411) (411) (411) (436)

4-12 5725 5725 5725 6065 12330 12330 12330 13070(114) (255) (255) (255) (270) (548) (548) (548) (581)7-12 9540 9540 9540 10110 20545 20545 20545 21780(191) (424) (424) (424) (450) (914) (914) (914) (969)

4

4-12 7445 7630 7630 8090 16035 16435 16435 17425(114) (331) (339) (339) (360) (713) (731) (731) (775)

6 10175 10175 10175 10785 21915 21915 21915 23230(152) (453) (453) (453) (480) (975) (975) (975) (1033)10 16960 16960 16960 17975 36525 36525 36525 38720

(254) (754) (754) (754) (800) (1625) (1625) (1625) (1722)

5

5-58 10405 11400 11925 12640 22415 24550 25685 27225(143) (463) (507) (530) (562) (997) (1092) (1143) (1211)7-12 15900 15900 15900 16855 34245 34245 34245 36300(191) (707) (707) (707) (750) (1523) (1523) (1523) (1615)

12-12 26500 26500 26500 28090 57075 57075 57075 60500(318) (1179) (1179) (1179) (1249) (2539) (2539) (2539) (2691)

6

6-34 13680 14985 17170 18200 29460 32275 36985 39205(171) (609) (667) (764) (810) (1310) (1436) (1645) (1744)

9 21060 22895 22895 24270 45360 49310 49310 52270(229) (937) (1018) (1018) (1080) (2018) (2193) (2193) (2325)15 38160 38160 38160 40445 82185 82185 82185 87120

(381) (1697) (1697) (1697) (1799) (3656) (3656) (3656) (3875)

7

7-78 17235 18885 21805 24775 37125 40670 46960 53360(200) (767) (840) (970) (1102) (1651) (1809) (2089) (2374)

10-12 26540 29070 31160 33030 57160 62615 67120 71145(267) (1181) (1293) (1386) (1469) (2543) (2785) (2986) (3165)

17-12 51935 51935 51935 55055 111865 111865 111865 118575(445) (2310) (2310) (2310) (2449) (4976) (4976) (4976) (5274)

8

9 21060 23070 26640 32360 45360 49690 57375 69695(229) (937) (1026) (1185) (1439) (2018) (2210) (2552) (3100)12 32425 35520 40700 43145 69835 76500 87665 92925

(305) (1442) (1580) (1810) (1919) (3106) (3403) (3900) (4133)20 67835 67835 67835 71905 146110 146110 146110 154875

(508) (3017) (3017) (3017) (3198) (6499) (6499) (6499) (6889)

9

10-18 25130 27530 31785 38930 54125 59290 68465 83850(257) (1118) (1225) (1414) (1732) (2408) (2637) (3045) (3730)

13-12 38690 42380 48940 54605 83330 91285 105405 117610(343) (1721) (1885) (2177) (2429) (3707) (4061) (4689) (5232)

22-12 83245 85855 85855 91005 179300 184920 184920 196015(572) (3703) (3819) (3819) (4048) (7976) (8226) (8226) (8719)

10

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 67410 97600 106915 123455 145195

(381) (2016) (2208) (2550) (2999) (4341) (4756) (5492) (6459)25 97500 105995 105995 112355 210000 228295 228295 241995

(635) (4337) (4715) (4715) (4998) (9341) (10155) (10155) (10764)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 14: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 71

328

325

326

327

324

324

324

323

Table 20 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for rebar in cracked concrete123456789

Rebar size

Effectiveembedment

in (mm)

TensionmdashϕNn or Nr ShearmdashϕVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

3

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

4

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

5

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

6

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

7

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

8

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

9

10-18 17800 19500 21120 22385 38340 42000 45490 48220(257) (792) (867) (939) (996) (1705) (1868) (2023) (2145)

13-12 27405 28160 28160 29850 59025 60655 60655 64290(343) (1219) (1253) (1253) (1328) (2626) (2698) (2698) (2860)

22-12 46935 46935 46935 49750 101090 101090 101090 107155(572) (2088) (2088) (2088) (2213) (4497) (4497) (4497) (4766)

10

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 22 - 37 as necessary Compare to the steel values in table 21

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constantoversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows

Forsand-lightweightλa=051Forall-lightweightλa = 0459TabularvaluesareforstaticloadsonlyForseismicloadsmultiplytabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 15: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

72 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 21 - Steel design strength for rebar12

Rebar size

ASTM A615 Grade 40 5 ASTM A615 Grade 60 5 ASTM A706 Grade 60 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV7

34290 2375

076435 3565

076600 3430

07(191) (106) (286) (159) (294) (153)

47800 4320

0711700 6480

0712000 6240

07(347) (192) (520) (288) (534) (278)

512090 6695

0718135 10045

0718600 9670

07(538) (298) (807) (447) (827) (430)

617160 9505

0725740 14255

0726400 13730

07(763) (423) (1145) (634) (1174) (611)

723400 12960

0735100 19440

0736000 18720

07(1041) (576) (1561) (865) (1601) (833)

830810 17065

0746215 25595

0747400 24650

07(1370) (759) (2056) (1139) (2108) (1096)

939000 21600

0758500 32400

0760000 31200

07(1735) (961) (2602) (1441) (2669) (1388)

1049530 27430

0774295 41150

0776200 39625

07(2203) (1220) (3305) (1830) (3390) (1763)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5 ASTM A706 Grade 60 rebar are considered ductile steel elements ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 16: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 73

328

325

326

327

324

324

324

323

Table 22 - Load adjustment factors for 3 rebar in uncracked concrete123

3Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 031 022 013 na na na 008 006 004 016 012 007 na na na

1-78 (48) 059 057 054 032 023 013 053 053 052 009 007 004 018 013 008 na na na2 (51) 060 057 054 032 024 014 054 053 052 010 007 004 019 015 009 na na na3 (76) 065 061 057 040 029 017 055 054 053 018 013 008 036 027 016 na na na

3-58 (92) 068 063 058 045 033 019 056 055 054 024 018 011 046 036 021 na na na4 (102) 070 065 059 048 035 020 057 056 054 028 021 012 049 040 025 na na na

4-58 (117) 073 067 060 054 039 023 058 057 055 034 026 015 054 043 031 057 na na5 (127) 075 069 061 058 042 024 059 057 055 038 029 017 058 046 033 059 na na

5-34 (146) 078 071 063 066 048 028 060 058 056 047 036 021 066 050 035 064 058 na6 (152) 080 072 063 069 050 029 061 059 056 051 038 023 069 052 036 065 059 na7 (178) 085 076 066 081 059 034 062 060 057 064 048 029 081 059 039 070 064 na8 (203) 090 080 068 092 067 039 064 062 058 078 058 035 092 067 043 075 068 na

8-34 (222) 093 082 069 100 074 043 065 063 059 089 067 040 100 074 045 079 071 0609 (229) 094 083 070 076 044 066 063 059 093 070 042 076 046 080 072 06110 (254) 099 087 072 084 049 068 065 060 100 082 049 084 050 084 076 06411 (279) 100 091 074 092 054 069 066 061 094 057 092 054 088 080 06812 (305) 094 077 100 058 071 067 062 100 064 100 058 092 084 07114 (356) 100 081 068 075 070 065 081 068 099 090 07616 (406) 086 078 078 073 067 099 078 100 097 08118 (457) 090 088 082 076 069 100 088 100 08624 (610) 100 100 092 085 075 100 10030 (762) 100 094 08136 (914) 100 087

gt48 (1219) 100

Table 23 - Load adjustment factors for 3 rebar in cracked concrete123

3Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorin tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12 3-38 4-12 7-12(mm) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 054 049 043 na na na 009 007 004 018 014 008 na na na

1-78 (48) 059 057 054 056 050 044 054 053 052 010 008 005 020 015 009 na na na2 (51) 060 057 054 057 051 044 054 053 052 011 008 005 022 017 010 na na na3 (76) 065 061 057 070 060 049 056 055 053 020 015 009 041 030 018 na na na

3-58 (92) 068 063 058 078 066 053 057 056 054 027 020 012 054 041 024 na na na4 (102) 070 065 059 084 070 055 058 056 055 031 023 014 063 047 028 na na na

4-58 (117) 073 067 060 093 076 058 059 057 055 039 029 018 078 058 035 060 na na5 (127) 075 069 061 099 080 060 060 058 056 044 033 020 087 066 039 062 na na

5-34 (146) 078 071 063 100 088 064 061 059 056 054 040 024 100 081 049 066 060 na6 (152) 080 072 063 091 066 062 060 057 058 043 026 086 052 068 062 na7 (178) 085 076 066 100 072 063 061 058 072 054 033 100 065 073 067 na8 (203) 090 080 068 078 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 082 069 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 083 070 085 067 064 060 079 048 085 083 076 06410 (254) 099 087 072 091 069 066 061 093 056 091 088 080 06711 (279) 100 091 074 098 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 073 069 064 073 100 096 087 07414 (356) 100 081 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 17: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

74 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 24 - Load adjustment factors for 4 rebar in uncracked concrete123

4Uncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 027 020 012 na na na 005 004 002 011 008 005 na na na2-12 (64) 059 057 054 031 023 013 053 053 052 009 007 004 018 013 008 na na na

3 (76) 061 058 055 033 024 014 054 053 052 012 009 005 024 017 010 na na na4 (102) 065 061 057 039 029 017 055 054 053 018 013 008 037 027 016 na na na5 (127) 069 064 058 045 033 019 057 055 054 026 019 011 046 037 023 na na na

5-34 (146) 071 066 060 050 036 021 058 056 054 032 023 014 050 041 028 056 na na6 (152) 072 067 060 051 038 022 058 057 055 034 025 015 052 042 030 057 na na7 (178) 076 069 062 059 043 025 059 058 055 042 031 019 059 046 033 061 na na

7-14 (184) 077 070 062 061 045 026 060 058 056 045 033 020 061 047 034 062 056 na8 (203) 080 072 063 067 049 029 061 059 056 052 038 023 067 051 036 066 059 na9 (229) 083 075 065 076 055 032 062 060 057 062 045 027 076 055 038 070 063 na10 (254) 087 078 067 084 062 036 063 061 058 072 053 032 084 062 041 073 066 na

11-14 (286) 092 081 069 095 069 041 065 062 059 086 063 038 095 069 044 078 070 05912 (305) 094 083 070 100 074 043 066 063 059 095 070 042 100 074 046 080 072 06114 (356) 100 089 073 086 050 069 065 061 100 088 053 086 051 087 078 06616 (406) 094 077 099 058 072 067 062 100 064 099 058 093 084 07118 (457) 100 080 100 065 074 070 064 077 100 065 098 089 07520 (508) 083 072 077 072 066 090 072 100 093 07922 (559) 087 079 080 074 067 100 079 098 08324 (610) 090 087 082 076 069 087 100 08630 (762) 100 100 090 083 073 100 09736 (914) 098 089 078 100

gt48 (1219) 100 100 087

Table 25 - Load adjustment factors for 4 rebar in cracked concrete123

4Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10 4-12 6 10(mm) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 049 045 041 na na na 006 004 003 012 009 005 na na na2-12 (64) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

3 (76) 061 058 055 060 053 046 054 054 053 013 010 006 026 020 012 na na na4 (102) 065 061 057 070 060 049 056 055 053 020 015 009 040 030 018 na na na5 (127) 069 064 058 080 067 053 057 056 054 028 021 013 056 042 025 na na na

5-34 (146) 071 066 060 088 073 056 058 057 055 035 026 016 070 052 031 057 na na6 (152) 072 067 060 091 075 057 059 057 055 037 028 017 074 056 033 059 na na7 (178) 076 069 062 100 083 062 060 058 056 047 035 021 094 070 042 063 na na

7-14 (184) 077 070 062 085 063 060 059 056 049 037 022 099 074 044 064 059 na8 (203) 080 072 063 091 066 061 059 057 057 043 026 100 086 051 068 062 na9 (229) 083 075 065 100 070 063 061 058 068 051 031 100 061 072 065 na10 (254) 087 078 067 075 064 062 058 080 060 036 072 076 069 na

11-14 (286) 092 081 069 081 066 063 059 095 071 043 081 080 073 06212 (305) 094 083 070 085 067 064 060 100 079 047 085 083 075 06414 (356) 100 089 073 095 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 073 069 063 100 073 100 096 087 07318 (457) 100 080 076 071 065 087 100 092 07820 (508) 083 079 074 067 100 097 08222 (559) 087 082 076 069 100 08624 (610) 090 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 18: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 75

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 26 - Load adjustment factors for 5 rebar in uncracked concrete123

5Uncracked Concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 025 018 011 na na na 004 003 002 008 006 003 na na na3-18 (79) 059 057 054 031 022 013 054 053 052 010 007 004 020 013 008 na na na

4 (102) 062 059 055 034 025 015 055 053 052 015 010 006 029 019 012 na na na4-58 (117) 064 060 056 037 027 016 055 054 053 018 012 007 036 024 014 na na na

5 (127) 065 061 057 039 028 017 056 054 053 021 013 008 039 027 016 na na na6 (152) 068 063 058 043 032 019 057 055 054 027 018 011 044 035 021 na na na7 (178) 071 066 059 048 036 021 058 056 054 034 022 013 049 040 027 na na na

7-18 (181) 071 066 060 049 036 021 058 056 054 035 023 014 050 040 027 057 na na8 (203) 074 068 061 054 039 023 059 057 055 041 027 016 054 043 032 061 na na9 (229) 077 070 062 060 044 026 060 058 056 050 032 019 060 047 034 065 056 na10 (254) 080 072 063 067 049 029 062 059 056 058 038 023 067 051 036 068 059 na11 (279) 083 074 065 074 054 032 063 060 057 067 044 026 074 054 038 071 062 na12 (305) 086 077 066 080 059 035 064 060 057 076 050 030 080 059 040 075 065 na14 (356) 091 081 069 094 069 040 066 062 059 096 063 038 094 069 044 081 070 05916 (406) 097 086 071 100 079 046 069 064 060 100 077 046 100 079 048 086 075 06318 (457) 100 090 074 089 052 071 066 061 092 055 089 052 091 079 06720 (508) 094 077 098 058 073 067 062 100 064 098 058 096 084 07122 (559) 099 079 100 063 075 069 064 074 100 063 100 088 07424 (610) 100 082 069 078 071 065 085 069 092 07726 (660) 085 075 080 073 066 095 075 095 08028 (711) 087 081 082 074 067 100 081 099 08330 (762) 090 086 085 076 069 086 100 08636 (914) 098 100 092 081 072 100 095

gt48 (1219) 100 100 092 080 100

Table 27 - Load adjustment factors for 5 rebar in cracked concrete123

5Cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactorintension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12 5-58 7-12 12-12(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 046 043 040 na na na 004 003 002 009 006 004 na na na3-18 (79) 059 057 054 056 050 044 054 053 052 010 007 004 020 015 009 na na na

4 (102) 062 059 055 062 055 046 055 054 053 015 011 006 030 022 013 na na na4-58 (117) 064 060 056 067 058 048 055 054 053 018 013 008 037 027 016 na na na

5 (127) 065 061 057 070 060 049 056 055 053 021 015 009 041 030 018 na na na6 (152) 068 063 058 078 066 053 057 056 054 027 020 012 054 040 024 na na na7 (178) 071 066 059 087 072 056 058 057 055 034 025 015 068 050 030 na na na

7-18 (181) 071 066 060 088 073 056 058 057 055 035 026 015 070 051 031 058 na na8 (203) 074 068 061 096 078 059 059 058 055 042 030 018 084 061 037 061 na na9 (229) 077 070 062 100 085 062 060 058 056 050 036 022 100 073 044 065 058 na10 (254) 080 072 063 091 066 062 059 057 058 043 026 085 051 068 061 na11 (279) 083 074 065 098 069 063 060 057 067 049 029 098 059 072 064 na12 (305) 086 077 066 100 073 064 061 058 077 056 034 100 067 075 067 na14 (356) 091 081 069 081 066 063 059 097 071 042 081 081 073 06116 (406) 097 086 071 089 069 065 061 100 086 052 089 086 078 06618 (457) 100 090 074 097 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 073 069 063 072 100 097 087 07322 (559) 099 079 076 071 065 083 100 091 07724 (610) 100 082 078 073 066 095 095 08026 (660) 085 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 19: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

76 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 28 - Load adjustment factors for 6 rebar in uncracked concrete123

6Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 024 018 010 na na na 003 002 001 007 005 002 na na na3-34 (95) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 008 na na na

4 (102) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 009 na na na5 (127) 062 059 056 035 026 015 055 054 053 017 011 006 033 022 012 na na na

5-14 (133) 063 060 056 036 026 015 055 054 053 018 012 006 036 023 013 na na na6 (152) 065 061 057 039 028 017 056 055 053 022 014 008 039 029 016 na na na7 (178) 067 063 058 043 031 018 057 055 054 028 018 010 043 036 020 na na na8 (203) 070 065 059 047 034 020 058 056 054 034 022 012 047 039 024 na na na

8-12 (216) 071 066 059 049 036 021 059 056 054 037 024 013 049 040 027 059 na na9 (229) 072 067 060 051 037 022 059 057 055 040 026 014 051 041 029 060 na na

10 (254) 075 069 061 056 041 024 060 058 055 047 031 017 056 044 032 064 na na10-34 (273) 077 070 062 060 044 026 061 058 055 053 034 019 060 047 034 066 057 na

12 (305) 080 072 063 067 049 029 062 059 056 062 040 022 067 050 036 070 060 na14 (356) 085 076 066 078 057 034 064 061 057 078 051 028 078 057 039 075 065 na16 (406) 090 080 068 089 065 038 066 062 058 096 062 034 089 065 042 080 070 na

16-34 (425) 091 081 069 093 069 040 067 063 059 100 067 037 093 069 043 082 071 05918 (457) 094 083 070 100 074 043 068 064 059 074 041 100 074 046 085 074 06120 (508) 099 087 072 082 048 070 065 060 087 048 082 049 090 078 06422 (559) 100 091 074 090 053 072 067 061 100 055 090 053 094 082 06724 (610) 094 077 098 058 074 068 062 063 098 058 099 085 07026 (660) 098 079 100 062 076 070 063 071 100 062 100 089 07328 (711) 100 081 067 078 071 064 080 067 092 07630 (762) 083 072 080 073 065 088 072 095 07836 (914) 090 086 086 077 068 100 086 100 086

gt48 (1219) 100 100 099 086 075 100 099

Table 29 - Load adjustment factors for 6 rebar in cracked concrete123

6Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15 6-34 9 15(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 044 042 039 na na na 003 002 001 007 005 003 na na na3-34 (95) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na

4 (102) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 010 na na na5 (127) 062 059 056 063 056 047 055 054 053 017 011 007 034 022 013 na na na

5-14 (133) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 014 na na na6 (152) 065 061 057 070 060 049 056 055 053 022 015 009 044 029 018 na na na7 (178) 067 063 058 077 065 052 057 055 054 028 019 011 056 037 022 na na na8 (203) 070 065 059 084 070 055 058 056 054 034 023 014 068 045 027 na na na

8-12 (216) 071 066 059 088 072 056 059 057 055 037 025 015 075 050 030 059 na na9 (229) 072 067 060 091 075 057 059 057 055 041 027 016 082 054 032 061 na na

10 (254) 075 069 061 099 080 060 060 058 055 048 032 019 095 063 038 064 na na10-34 (273) 077 070 062 100 084 062 061 058 056 053 035 021 100 070 042 066 058 na

12 (305) 080 072 063 091 066 062 059 057 063 042 025 083 050 070 061 na14 (356) 085 076 066 100 072 064 061 058 079 052 031 100 063 076 066 na16 (406) 090 080 068 078 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 081 069 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 083 070 085 068 064 060 076 046 085 086 075 06320 (508) 099 087 072 091 070 065 061 089 054 091 090 079 06622 (559) 100 091 074 098 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 074 069 063 070 100 099 086 07326 (660) 098 079 076 070 064 079 100 090 07628 (711) 100 081 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 20: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 77

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 30 - Load adjustment factors for 7 rebar in uncracked concrete123

7Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 023 017 010 na na na 003 002 001 005 004 002 na na na4-38 (111) 059 057 054 030 022 013 054 053 052 011 007 004 022 014 007 na na na

5 (127) 061 058 055 032 024 014 054 053 052 013 009 004 027 017 009 na na na5-12 (140) 062 059 055 034 025 015 055 054 052 015 010 005 031 020 010 na na na

6 (152) 063 060 056 035 026 015 055 054 052 017 011 006 035 023 012 na na na7 (178) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 015 na na na8 (203) 067 063 058 042 031 018 057 055 053 027 017 009 043 035 018 na na na9 (229) 069 064 059 045 033 020 058 056 054 032 021 011 046 038 021 na na na

9-78 (251) 071 066 059 049 036 021 059 056 054 037 024 012 049 040 024 059 na na10 (254) 071 066 060 049 036 021 059 057 054 038 024 012 050 040 025 059 na na11 (279) 073 067 060 053 039 023 060 057 055 043 028 014 053 043 029 062 na na12 (305) 075 069 061 057 042 025 060 058 055 049 032 016 057 045 033 065 na na

12-12 (318) 076 070 062 060 044 026 061 058 055 052 034 017 060 046 034 066 057 na14 (356) 080 072 063 067 049 029 062 059 056 062 040 021 067 050 036 070 060 na16 (406) 084 075 065 076 056 033 064 060 057 076 049 025 076 056 038 075 065 na18 (457) 088 079 067 086 063 037 066 062 057 091 059 030 086 063 041 079 068 na

19-12 (495) 091 081 069 093 068 040 067 063 058 100 066 034 093 068 043 082 071 05720 (508) 092 082 069 095 070 041 067 063 058 069 035 095 070 044 083 072 05822 (559) 097 085 071 100 077 045 069 064 059 080 041 100 077 047 087 076 06024 (610) 100 088 073 084 049 071 066 060 091 046 084 050 091 079 06326 (660) 091 075 091 053 073 067 061 100 052 091 054 095 082 06628 (711) 094 077 098 058 074 068 062 058 098 058 099 085 06830 (762) 098 079 100 062 076 070 062 065 100 062 100 088 07136 (914) 100 084 074 081 073 065 085 074 097 077

gt48 (1219) 096 099 092 081 070 100 099 100 089

Table 31 - Load adjustment factors for 7 rebar in cracked concrete123

7Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12 7-78 10-12 17-12(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 043 041 038 na na na 003 002 001 006 004 002 na na na4-38 (111) 059 057 054 056 050 044 054 053 052 011 008 005 022 016 010 na na na

5 (127) 061 058 055 059 052 045 054 054 053 013 010 006 027 019 012 na na na5-12 (140) 062 059 055 062 054 046 055 054 053 015 011 007 031 022 013 na na na

6 (152) 063 060 056 064 056 047 055 054 053 018 013 008 035 025 015 na na na7 (178) 065 061 057 070 060 049 056 055 054 022 016 010 044 032 019 na na na8 (203) 067 063 058 076 064 052 057 056 054 027 020 012 054 039 024 na na na9 (229) 069 064 059 082 068 054 058 056 055 032 023 014 065 047 028 na na na

9-78 (251) 071 066 059 087 072 056 059 057 055 037 027 016 074 054 032 059 na na10 (254) 071 066 060 088 073 056 059 057 055 038 027 016 076 055 033 059 na na11 (279) 073 067 060 095 077 059 060 058 056 044 032 019 087 063 038 062 na na12 (305) 075 069 061 100 082 061 060 058 056 050 036 022 100 072 043 065 na na

12-12 (318) 076 070 062 084 062 061 059 056 053 038 023 100 077 046 066 059 na14 (356) 080 072 063 091 066 062 060 057 063 045 027 091 054 070 063 na16 (406) 084 075 065 100 071 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 079 067 076 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 081 069 080 067 064 060 100 075 045 080 082 074 06220 (508) 092 082 069 082 067 064 060 077 046 082 084 075 06322 (559) 097 085 071 087 069 065 061 089 054 087 088 079 06624 (610) 100 088 073 093 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 073 068 063 069 099 095 086 07228 (711) 094 077 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 21: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

78 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 32 - Load adjustment factors for 8 rebar in uncracked concrete123

8Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 023 017 010 na na na 002 001 001 005 003 001 na na na

5 (127) 059 057 054 030 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 061 058 055 033 024 014 055 053 052 014 009 004 029 019 009 na na na

6-14 (159) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na7 (178) 063 060 056 036 026 015 055 054 052 018 012 006 036 023 011 na na na8 (203) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 014 na na na9 (229) 067 063 058 041 030 018 057 055 053 026 017 008 042 034 016 na na na

10 (254) 069 064 058 044 033 019 058 056 053 031 020 010 045 037 019 na na na11 (279) 070 065 059 048 035 021 058 056 054 035 023 011 048 039 022 na na na

11-14 (286) 071 066 059 048 036 021 059 056 054 037 024 011 049 040 023 058 na na12 (305) 072 067 060 051 037 022 059 057 054 040 026 013 051 041 025 060 na na13 (330) 074 068 061 054 040 023 060 057 055 046 030 014 055 044 028 063 na na14 (356) 076 069 062 058 043 025 061 058 055 051 033 016 058 046 032 065 na na

14-14 (362) 076 070 062 059 044 026 061 058 055 052 034 016 059 046 032 066 057 na16 (406) 080 072 063 067 049 029 062 059 056 062 040 019 067 050 036 070 060 na18 (457) 083 075 065 075 055 032 064 060 056 074 048 023 075 055 038 074 064 na20 (508) 087 078 067 083 061 036 065 061 057 087 056 027 083 061 040 078 067 na22 (559) 091 081 068 092 067 040 067 063 058 100 065 031 092 067 043 082 071 na

22-14 (565) 091 081 069 093 068 040 067 063 058 066 032 093 068 043 082 071 05624 (610) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05826 (660) 098 086 072 100 080 047 070 065 059 084 040 100 080 048 089 077 06028 (711) 100 089 073 086 050 071 066 060 094 045 086 051 092 080 06230 (762) 092 075 092 054 073 067 060 100 050 092 054 095 083 06536 (914) 100 080 100 065 077 070 063 065 100 065 100 091 071

gt48 (1219) 090 086 086 077 067 100 086 100 082

Table 33 - Load adjustment factors for 8 rebar in cracked concrete123

8Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edge distance in shear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20 9 12 20(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 042 040 038 na na na 002 002 001 005 003 002 na na na

5 (127) 059 057 054 056 050 044 054 053 052 011 007 004 022 015 009 na na na6 (152) 061 058 055 060 053 046 055 054 053 014 010 006 029 019 012 na na na

6-14 (159) 062 059 055 061 054 046 055 054 053 015 010 006 031 021 012 na na na7 (178) 063 060 056 065 057 047 055 054 053 018 012 007 036 024 015 na na na8 (203) 065 061 057 070 060 049 056 055 053 022 015 009 044 030 018 na na na9 (229) 067 063 058 075 064 051 057 055 054 026 018 011 053 036 021 na na na

10 (254) 069 064 058 080 067 053 058 056 054 031 021 013 062 042 025 na na na11 (279) 070 065 059 086 071 055 058 056 055 036 024 014 072 048 029 na na na

11-14 (286) 071 066 059 087 072 056 059 057 055 037 025 015 074 050 030 059 na na12 (305) 072 067 060 091 075 057 059 057 055 041 027 016 082 055 033 061 na na13 (330) 074 068 061 097 079 059 060 058 055 046 031 019 092 062 037 063 na na14 (356) 076 069 062 100 083 062 061 058 056 051 035 021 100 069 042 065 na na

14-14 (362) 076 070 062 084 062 061 058 056 053 036 021 071 043 066 058 na16 (406) 080 072 063 091 066 062 059 057 063 042 025 085 051 070 061 na18 (457) 083 075 065 100 070 064 061 058 075 050 030 100 061 074 065 na20 (508) 087 078 067 075 065 062 058 088 059 035 071 078 069 na22 (559) 091 081 068 080 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 081 069 080 067 063 059 069 042 080 082 072 06124 (610) 094 083 070 085 068 064 060 078 047 085 086 075 06326 (660) 098 086 072 090 070 065 061 088 053 090 089 078 06628 (711) 100 089 073 095 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 22: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 79

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 34 - Load adjustment factors for 9 rebar in uncracked concrete12

9Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 022 016 010 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na6 (152) 060 057 054 031 023 014 054 053 052 012 008 004 024 016 007 na na na7 (178) 062 059 055 034 025 015 055 054 052 015 010 005 030 020 009 na na na

7-14 (184) 062 059 055 034 025 015 055 054 052 016 010 005 032 021 010 na na na8 (203) 063 060 056 036 027 016 055 054 052 018 012 006 037 024 011 na na na9 (229) 065 061 057 039 028 017 056 055 053 022 014 007 040 029 013 na na na

10 (254) 066 062 057 041 030 018 057 055 053 026 017 008 042 033 016 na na na11 (279) 068 064 058 044 032 019 057 056 053 030 019 009 045 037 018 na na na12 (305) 070 065 059 047 034 020 058 056 054 034 022 010 047 039 020 na na na

12-78 (327) 071 066 060 049 036 021 059 057 054 038 024 011 050 040 023 059 na na13 (330) 071 066 060 050 036 021 059 057 054 038 025 012 050 041 023 059 na na14 (356) 073 067 060 053 039 023 059 057 054 043 028 013 053 043 026 061 na na16 (406) 076 070 062 060 044 026 061 058 055 052 034 016 060 046 031 066 na na

16-14 (413) 077 070 062 061 044 026 061 058 055 053 035 016 061 047 032 066 057 na18 (457) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na20 (508) 083 075 065 075 055 032 063 060 056 073 047 022 075 055 038 073 064 na22 (559) 086 077 066 082 060 035 065 061 057 084 055 025 082 060 040 077 067 na24 (610) 090 080 068 089 066 038 066 062 057 096 062 029 089 066 042 080 070 na

25-14 (641) 092 081 069 094 069 040 067 063 058 100 067 031 094 069 044 083 071 05526 (660) 093 082 069 097 071 042 068 063 058 070 033 097 071 045 084 073 05628 (711) 096 085 071 100 077 045 069 064 059 078 036 100 077 047 087 075 05830 (762) 099 087 072 082 048 070 065 059 087 040 082 049 090 078 06036 (914) 100 094 077 099 058 074 068 061 100 053 099 058 099 085 066

gt48 (1219) 100 086 100 077 082 074 065 082 100 077 100 099 076

Table 35 - Load adjustment factors for 9 rebar in cracked concrete12

9Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12 10-18 13-12 22-12(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 1-34 (44) na na na 041 039 038 na na na 002 001 001 004 002 001 na na na

5-58 (143) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na6 (152) 060 057 054 057 051 044 054 053 052 012 008 005 024 016 009 na na na7 (178) 062 059 055 061 054 046 055 054 052 015 010 006 030 020 012 na na na

7-14 (184) 062 059 055 062 055 046 055 054 053 016 010 006 032 021 012 na na na8 (203) 063 060 056 065 057 048 055 054 053 019 012 007 037 024 014 na na na9 (229) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 017 na na na

10 (254) 066 062 057 074 063 051 057 055 054 026 017 010 052 034 020 na na na11 (279) 068 064 058 079 067 053 057 056 054 030 019 011 060 039 023 na na na12 (305) 070 065 059 084 070 055 058 056 054 034 022 013 068 044 026 na na na

12-78 (327) 071 066 060 088 073 056 059 057 055 038 025 014 076 049 029 059 na na13 (330) 071 066 060 089 073 056 059 057 055 039 025 015 077 050 029 059 na na14 (356) 073 067 060 094 077 058 060 057 055 043 028 016 086 056 033 062 na na16 (406) 076 070 062 100 084 062 061 058 056 053 034 020 100 068 040 066 na na

16-14 (413) 077 070 062 085 063 061 058 056 054 035 020 070 041 066 058 na18 (457) 080 072 063 091 066 062 059 056 063 041 024 082 048 070 061 na20 (508) 083 075 065 099 070 064 060 057 073 048 028 095 056 074 064 na22 (559) 086 077 066 100 074 065 061 058 085 055 032 100 064 077 067 na24 (610) 090 080 068 078 066 062 059 097 063 037 073 081 070 na

25-14 (641) 092 081 069 081 067 063 059 100 068 040 079 083 072 06026 (660) 093 082 069 082 068 063 059 071 041 082 084 073 06128 (711) 096 085 071 087 069 064 060 079 046 087 087 076 06330 (762) 099 087 072 091 070 065 061 088 051 091 090 078 06536 (914) 100 094 077 100 074 068 063 100 067 100 099 086 072

gt48 (1219) 100 086 083 074 067 100 100 099 083

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 23: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

80 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN4 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 36 - Load adjustment factors for 10 rebar in uncracked concrete 12

10Uncracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 022 016 009 na na na 002 001 000 003 002 001 na na na6-14 (159) 059 057 054 031 022 013 054 053 052 011 007 003 022 014 007 na na na

7 (178) 060 058 055 032 024 014 054 053 052 013 008 004 026 017 008 na na na8 (203) 062 059 055 034 025 015 055 054 052 016 010 005 031 020 010 na na na9 (229) 063 060 056 036 027 016 055 054 052 019 012 006 037 024 011 na na na10 (254) 065 061 057 039 028 017 056 055 053 022 014 007 039 029 013 na na na11 (279) 066 062 057 041 030 018 057 055 053 025 016 008 042 033 015 na na na12 (305) 068 063 058 043 032 019 057 055 053 029 019 009 044 036 017 na na na13 (330) 069 064 059 046 034 020 058 056 054 033 021 010 047 038 020 na na na14 (356) 071 066 059 048 036 021 059 056 054 036 024 011 049 040 022 na na na

14-14 (362) 071 066 060 049 036 021 059 056 054 037 024 011 050 040 023 059 na na15 (381) 072 067 060 051 037 022 059 057 054 040 026 012 052 042 024 060 na na16 (406) 074 068 061 054 039 023 060 057 054 045 029 013 054 043 027 062 na na17 (432) 075 069 061 057 042 024 060 058 055 049 032 015 057 045 029 064 na na18 (457) 077 070 062 060 044 026 061 058 055 053 035 016 060 047 032 066 057 na20 (508) 080 072 063 067 049 029 062 059 055 062 040 019 067 051 036 070 060 na22 (559) 083 074 065 074 054 032 063 060 056 072 047 022 074 054 038 073 063 na24 (610) 086 077 066 080 059 035 065 061 057 082 053 025 080 059 040 076 066 na26 (660) 089 079 067 087 064 037 066 062 057 092 060 028 087 064 042 079 069 na28 (711) 091 081 069 094 069 040 067 063 058 100 067 031 094 069 044 082 071 05530 (762) 094 083 070 100 074 043 068 064 058 074 035 100 074 046 085 074 05736 (914) 100 090 074 089 052 072 066 060 098 045 089 052 094 081 063

gt48 (1219) 100 082 100 069 079 072 063 100 070 100 069 100 094 072

Table 37 - Load adjustment factors for 10 rebar in cracked concrete 12

10Cracked concrete

Spacing factor in tension

ƒAN

Edge distance factor in tension

ƒRN

Spacing factor in shear3

ƒAV

Edge distance in shear

Concrete thickness factor in shear4

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25 11-14 15 25(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na 040 039 037 na na na 002 001 001 003 002 001 na na na6-14 (159) 059 057 054 056 050 044 054 053 052 011 007 004 022 014 008 na na na

7 (178) 060 058 055 058 052 045 054 053 052 013 008 005 026 017 009 na na na8 (203) 062 059 055 062 055 046 055 054 052 016 010 006 032 021 011 na na na9 (229) 063 060 056 066 057 048 055 054 053 019 012 007 038 025 014 na na na10 (254) 065 061 057 070 060 049 056 055 053 022 014 008 044 029 016 na na na11 (279) 066 062 057 074 063 051 057 055 053 026 017 009 051 033 018 na na na12 (305) 068 063 058 078 066 053 057 055 054 029 019 010 058 038 021 na na na13 (330) 069 064 059 082 069 054 058 056 054 033 021 012 066 043 024 na na na14 (356) 071 066 059 087 072 056 059 056 054 037 024 013 073 048 026 na na na

14-14 (362) 071 066 060 088 073 056 059 057 054 038 025 014 075 049 027 059 na na15 (381) 072 067 060 091 075 057 059 057 055 041 026 015 082 053 029 061 na na16 (406) 074 068 061 096 078 059 060 057 055 045 029 016 090 058 032 063 na na17 (432) 075 069 061 100 081 061 060 058 055 049 032 018 098 064 035 064 na na18 (457) 077 070 062 085 062 061 058 056 054 035 019 100 070 038 066 057 na20 (508) 080 072 063 091 066 062 059 056 063 041 023 082 045 070 061 na22 (559) 083 074 065 098 069 063 060 057 072 047 026 094 052 073 063 na24 (610) 086 077 066 100 073 065 061 057 082 054 030 100 059 077 066 na26 (660) 089 079 067 077 066 062 058 093 060 033 067 080 069 na28 (711) 091 081 069 081 067 063 059 100 068 037 075 083 072 05930 (762) 094 083 070 085 068 064 059 075 041 083 086 074 06136 (914) 100 090 074 097 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 079 072 065 100 084 100 100 094 077

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 24: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 81

328

325

326

327

324

324

324

323

3233 Hilti HIT-HY 200-AR Adhesive with Hilti HAS threaded rod

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

drilli

ngm

etho

d

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Table 38 - HAS threaded rod specifications

Setting information Symbol UnitsNominal rod diameter

38 12 58 34 78 1 1-14Nominal bit diameter do in 716 916 34 78 1 1-18 1-38

Standard effective embedment hefstd

in 3-38 4-12 5-58 6-34 7-78 9 11-14(mm) (86) (114) (143) (171) (200) (229) (286)

Effective embedment

minimum hefmin

in 2-38 2-34 3-18 3-12 3-12 4 5(mm) (60) (70) (79) (89) (89) (102) (127)

maximum hefmax

in 7-12 10 12-12 15 17-12 20 25(mm) (191) (254) (318) (381) (445) (508) (635)

Minimum diameter of fixture hole through-set in 12 58 13161 15161 1-181 1-141 1-121

Minimum diameter of fixture hole preset in 716 916 1116 1316 1516 1-18 1-38

Installationtorque Tinst

ft-lb 15 30 60 100 125 150 200(Nm) (20) (40) (80) (136) (169) (203) (271)

1 Install using (2) washers See Figure 11

Figure 10 - HAS threaded rods

Figure 11 - Installation with (2) washers

HAS-E carbon steel threaded rod specificationsCarbon steel rods conform to ISO 898 class 58 with a minimum tensile strength of 725 ksi (500 MPa) and a minimum yield strength of 58 ksi (400 MPa)HAS-EnutsconformtoSAEJ995Grade5HAS-EwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS-ErodnutandwasherhasanelectroplatedzinccoatingconformingtoASTMB633SC1

HAS Super high strength threaded rod specificationsCarbonsteelrodsmanufacturedfromASTMA193GradeB7withaminimumtensilestrengthof125ksi(862MPa)and a minimum yield strength of 105 ksi (724 MPa)HASSupernutsconformtoSAEJ995Grade5HASSuperwashersconformtoASTMF884HVandANSIB18221TypeAPlainHAS Super rods nuts and washers except the 78-in diameter have an electroplated zinc coating conforming to ASTM B633 SC178-in HAS Super rods nuts and washers are hot-dip galvanized in accordance with ASTM A153

HAS-R 304 stainless steel38- 12- and 58-in rods manufactured from AISI Type 304 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 304 stainless steel conforming to ASTM F593 Condition CW or cold workedAISI Type 304 stainless steel nuts conform to ASTM F594AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

HAS-R 316 stainless steel38- 12- and 58-in rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689 MPa) and a minimum yield strength of 65 ksi (448 MPa)34- 1- and 1 14-in rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CWAISI Type 316 stainless steel nuts conform to ASTM F594AISI Type 316 stainless steel washers conform to ASTM A240 and ANSI B18221 Type A Plain

Figure 9 -HAS threaded rod installation conditions

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 25: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

82 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 39 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in uncracked concrete 12345678

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 2855 3125 3415 3620 3075 3370 3680 3900(60) (127) (139) (152) (161) (137) (150) (164) (173)

3-38 4835 4855 4855 5150 10415 10460 10460 11085(86) (215) (216) (216) (229) (463) (465) (465) (493)

4-12 6475 6475 6475 6865 13945 13945 13945 14785(114) (288) (288) (288) (305) (620) (620) (620) (658)7-12 10790 10790 10790 11440 23245 23245 23245 24640(191) (480) (480) (480) (509) (1034) (1034) (1034) (1096)

12

2-34 3555 3895 4500 5510 7660 8395 9690 11870(70) (158) (173) (200) (245) (341) (373) (431) (528)

4-12 7445 8155 8635 9150 16035 17570 18595 19710(114) (331) (363) (384) (407) (713) (782) (827) (877)

6 11465 11510 11510 12200 24690 24795 24795 26280(152) (510) (512) (512) (543) (1098) (1103) (1103) (1169)10 19185 19185 19185 20335 41320 41320 41320 43800

(254) (853) (853) (853) (905) (1838) (1838) (1838) (1948)

58

3-18 4310 4720 5450 6675 9280 10165 11740 14380(79) (192) (210) (242) (297) (413) (452) (522) (640)

5-58 10405 11400 13165 14300 22415 24550 28350 30795(143) (463) (507) (586) (636) (997) (1092) (1261) (1370)7-12 16020 17550 17985 19065 34505 37800 38740 41065(191) (713) (781) (800) (848) (1535) (1681) (1723) (1827)

12-12 29975 29975 29975 31775 64565 64565 64565 68440(318) (1333) (1333) (1333) (1413) (2872) (2872) (2872) (3044)

34

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

6-34 13680 14985 17305 20590 29460 32275 37265 44350(171) (609) (667) (770) (916) (1310) (1436) (1658) (1973)

9 21060 23070 25900 27455 45360 49690 55785 59130(229) (937) (1026) (1152) (1221) (2018) (2210) (2481) (2630)15 43165 43165 43165 45755 92975 92975 92975 98550

(381) (1920) (1920) (1920) (2035) (4136) (4136) (4136) (4384)

78

3-12 5105 5595 6460 7910 11000 12050 13915 17040(89) (227) (249) (287) (352) (489) (536) (619) (758)

7-78 17235 18885 21805 26705 37125 40670 46960 57515(200) (767) (840) (970) (1188) (1651) (1809) (2089) (2558)

10-12 26540 29070 33570 37365 57160 62615 72300 80485(267) (1181) (1293) (1493) (1662) (2543) (2785) (3216) (3580)

17-12 57100 58755 58755 62280 122990 126545 126545 134140(445) (2540) (2614) (2614) (2770) (5471) (5629) (5629) (5967)

1

4 6240 6835 7895 9665 13440 14725 17000 20820(102) (278) (304) (351) (430) (598) (655) (756) (926)

9 21060 23070 26640 32625 45360 49690 57375 70270(229) (937) (1026) (1185) (1451) (2018) (2210) (2552) (3126)12 32425 35520 41015 48805 69835 76500 88335 105120

(305) (1442) (1580) (1824) (2171) (3106) (3403) (3929) (4676)20 69765 76425 76740 81345 150265 164605 165285 175205

(508) (3103) (3400) (3414) (3618) (6684) (7322) (7352) (7793)

1-14

5 8720 9555 11030 13510 18785 20575 23760 29100(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

11-14 29430 32240 37230 45595 63395 69445 80185 98205(286) (1309) (1434) (1656) (2028) (2820) (3089) (3567) (4368)15 45315 49640 57320 70200 97600 106915 123455 151200

(381) (2016) (2208) (2550) (3123) (4341) (4756) (5492) (6726)25 97500 106805 119905 127100 210000 230045 258260 273755

(635) (4337) (4751) (5334) (5654) (9341) (10233) (11488) (12177)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 26: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 83

328

325

326

327

324

324

324

323

Table 40 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for threaded rod in cracked concrete 123456789

Nominal anchor

diameter in

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38

2-38 1900 1900 1900 2015 2045 2045 2045 2165(60) (85) (85) (85) (90) (91) (91) (91) (96)

3-38 2700 2700 2700 2860 5810 5810 5810 6160(86) (120) (120) (120) (127) (258) (258) (258) (274)

4-12 3600 3600 3600 3815 7750 7750 7750 8215(114) (160) (160) (160) (170) (345) (345) (345) (365)7-12 5995 5995 5995 6355 12915 12915 12915 13690(191) (267) (267) (267) (283) (574) (574) (574) (609)

12

2-34 2520 2760 2950 3130 5425 5945 6355 6735(70) (112) (123) (131) (139) (241) (264) (283) (300)

4-12 4830 4830 4830 5120 10400 10400 10400 11025(114) (215) (215) (215) (228) (463) (463) (463) (490)

6 6440 6440 6440 6825 13870 13870 13870 14700(152) (286) (286) (286) (304) (617) (617) (617) (654)10 10730 10730 10730 11375 23115 23115 23115 24500

(254) (477) (477) (477) (506) (1028) (1028) (1028) (1090)

58

3-18 3050 3345 3860 4470 6575 7200 8315 9625(79) (136) (149) (172) (199) (292) (320) (370) (428)

5-58 7370 7590 7590 8045 15875 16345 16345 17325(143) (328) (338) (338) (358) (706) (727) (727) (771)7-12 10120 10120 10120 10725 21790 21790 21790 23100(191) (450) (450) (450) (477) (969) (969) (969) (1028)

12-12 16865 16865 16865 17875 36320 36320 36320 38500(318) (750) (750) (750) (795) (1616) (1616) (1616) (1713)

34

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

6-34 9690 10615 10980 11635 20870 22860 23645 25065(171) (431) (472) (488) (518) (928) (1017) (1052) (1115)

9 14640 14640 14640 15515 31530 31530 31530 33420(229) (651) (651) (651) (690) (1403) (1403) (1403) (1487)15 24395 24395 24395 25860 52550 52550 52550 55700

(381) (1085) (1085) (1085) (1150) (2338) (2338) (2338) (2478)

78

3-12 3620 3965 4575 5605 7790 8535 9855 12070(89) (161) (176) (204) (249) (347) (380) (438) (537)

7-78 12210 12665 12665 13425 26300 27275 27275 28910(200) (543) (563) (563) (597) (1170) (1213) (1213) (1286)

10-12 16885 16885 16885 17900 36370 36370 36370 38550(267) (751) (751) (751) (796) (1618) (1618) (1618) (1715)

17-12 28140 28140 28140 29830 60615 60615 60615 64250(445) (1252) (1252) (1252) (1327) (2696) (2696) (2696) (2858)

1

4 4420 4840 5590 6845 9520 10430 12040 14750(102) (197) (215) (249) (304) (423) (464) (536) (656)

9 14920 16340 16615 17610 32130 35195 35785 37930(229) (664) (727) (739) (783) (1429) (1566) (1592) (1687)12 22150 22150 22150 23480 47710 47710 47710 50575

(305) (985) (985) (985) (1044) (2122) (2122) (2122) (2250)20 36920 36920 36920 39135 79520 79520 79520 84290

(508) (1642) (1642) (1642) (1741) (3537) (3537) (3537) (3749)

1-14

5 6175 6765 7815 9570 13305 14575 16830 20610(127) (275) (301) (348) (426) (592) (648) (749) (917)

11-14 20850 22840 26130 27700 44905 49190 56285 59660(286) (927) (1016) (1162) (1232) (1997) (2188) (2504) (2654)15 32095 34840 34840 36935 69135 75045 75045 79545

(381) (1428) (1550) (1550) (1643) (3075) (3338) (3338) (3538)25 58070 58070 58070 61555 125075 125075 125075 132580

(635) (2583) (2583) (2583) (2738) (5564) (5564) (5564) (5897)1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 42 - 55 as necessary Compare to the steel values in table 41

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 ShorttermelevatedconcretetemperaturesarethosethatoccuroverbriefintervalsegasaresultofdiurnalcyclingLongtermconcretetemperaturesareroughlyconstantoversignificantperiods of time

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9 Tabular values are for static loads only For seismic loads multiply cracked concrete tabular values by the following reduction factors 38-into34-indiameter-αseis = 060 78-into1-14-indiameter-αseis = 075 See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 27: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

84 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 41 - Steel design strength for Hilti HAS threaded rods 3

Nominal anchor

diameterin

HAS-E 5 HAS Super ASTM A193 B7 5 HAS SS AISI 304316 SS 5

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

Tensile1

ϕNsa

lb (kN)

Shear2

ϕVsa

lb (kN) αseisV4

383655 1685

077265 3150

075040 2325

07(163) (75) (323) (140) (224) (103)

126690 3705

0713300 6915

079225 5110

07(298) (165) (592) (308) (410) (227)

5810650 5900

0721190 11020

0714690 8135

07(474) (262) (943) (490) (653) (362)

3415765 8730

0731360 16305

0718480 10235

07(701) (388) (1395) (725) (822) (455)

7821755 12050

0743285 22505

0725510 14125

07(968) (536) (1925) (1001) (1135) (628)

128540 15805

0756785 29525

0733465 18535

07(1270) (703) (2526) (1313) (1489) (824)

1-1445670 25295

0790850 47240

0753540 29655

07(2031) (1125) (4041) (2101) (2382) (1319)

1Tensile=ϕAseN futa as noted in ACI 318 Appendix D2Shear=ϕ060AseN futa as noted in ACI 318 Appendix D3 See section 3173 to convert design strength (factored resistance) value to ASD value4 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications5HASSuperrodsareconsideredductilesteelelementsHASstandard-EandHASSSrodsareconsideredbrittlesteelelements

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 28: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 85

328

325

326

327

324

324

324

323

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 42 - Load adjustment factors for 38-in diameter threaded rods in uncracked concrete123

38-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 037 030 022 013 na na na na 023 007 005 003 044 014 011 006 na na na na1-78 (48) 059 059 057 054 038 031 023 013 057 053 053 052 025 008 006 004 038 016 012 007 na na na na

2 (51) 060 060 057 054 040 032 023 014 057 053 053 052 028 009 006 004 040 017 013 008 na na na na3 (76) 065 065 061 057 051 039 028 017 061 055 054 053 051 016 012 007 051 032 024 014 na na na na

3-58 (92) 068 068 063 058 060 044 032 019 063 056 055 053 068 021 016 009 060 042 032 019 072 na na na4 (102) 069 069 065 059 066 047 034 020 064 057 055 054 079 024 018 011 066 047 037 022 075 na na na

4-58 (117) 072 072 067 060 076 052 038 022 066 058 056 054 098 030 023 014 076 052 041 027 081 055 na na5 (127) 074 074 069 061 082 055 040 023 068 058 057 055 100 034 026 015 082 055 043 031 084 057 na na

5-34 (146) 078 078 071 063 095 063 046 027 070 059 058 055 042 031 019 095 063 048 034 091 061 056 na6 (152) 079 079 072 063 099 066 048 028 071 060 058 056 045 034 020 099 066 049 034 092 063 057 na7 (178) 084 084 076 066 100 077 056 032 075 061 059 057 057 042 025 100 077 056 037 100 068 061 na8 (203) 089 089 080 068 088 064 037 079 063 061 058 069 052 031 088 064 041 100 072 066 na

8-34 (222) 093 093 082 069 096 070 041 081 064 062 058 079 059 035 096 070 043 076 069 0589 (229) 094 094 083 070 099 072 042 082 065 062 059 083 062 037 099 072 044 077 069 05910 (254) 099 099 087 072 100 080 046 086 066 063 060 097 072 043 100 080 048 081 073 06211 (279) 100 100 091 074 088 051 089 068 065 060 100 083 050 088 051 085 077 06512 (305) 094 077 096 056 093 070 066 061 095 057 096 056 088 080 06814 (356) 100 081 100 065 100 073 069 063 100 072 100 065 096 087 07316 (406) 086 074 100 076 071 065 088 074 100 093 07818 (457) 090 083 079 074 067 100 083 098 08324 (610) 100 100 089 082 073 100 100 09630 (762) 099 090 079 10036 (914) 100 098 084

gt48 (1219) 100 096

Table 43 - Load adjustment factors for 38-in diameter threaded rods in cracked concrete123

38-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12 2-38 3-38 4-12 7-12(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 054 054 049 043 na na na na 025 009 007 004 049 018 014 008 na na na na1-78 (48) 059 059 057 054 055 055 050 044 057 054 053 052 027 010 008 005 055 020 015 009 na na na na

2 (51) 060 060 057 054 057 057 051 044 057 054 053 052 030 011 008 005 060 022 017 010 na na na na3 (76) 065 065 061 057 069 069 060 049 061 056 055 053 055 020 015 009 088 041 030 018 na na na na

3-58 (92) 068 068 063 058 078 078 066 053 064 057 056 054 073 027 020 012 100 054 041 024 074 na na na4 (102) 069 069 065 059 083 083 070 055 065 058 056 055 085 031 023 014 063 047 028 077 na na na

4-58 (117) 072 072 067 060 092 092 076 058 067 059 057 055 100 039 029 018 078 058 035 083 060 na na5 (127) 074 074 069 061 098 098 080 060 069 060 058 056 044 033 020 087 066 039 086 062 na na

5-34 (146) 078 078 071 063 100 100 088 064 071 061 059 056 054 040 024 100 081 049 093 066 060 na6 (152) 079 079 072 063 091 066 072 062 060 057 058 043 026 086 052 095 068 062 na7 (178) 084 084 076 066 100 072 076 063 061 058 072 054 033 100 065 100 073 067 na8 (203) 089 089 080 068 078 080 065 063 059 089 066 040 078 078 071 na

8-34 (222) 093 093 082 069 083 083 067 064 060 100 076 046 083 082 074 0639 (229) 094 094 083 070 085 084 067 064 060 079 048 085 083 076 064

10 (254) 099 099 087 072 091 087 069 066 061 093 056 091 088 080 06711 (279) 100 100 091 074 098 091 071 067 062 100 064 098 092 084 07012 (305) 094 077 100 095 073 069 064 073 100 096 087 07414 (356) 100 081 100 077 072 066 092 100 094 07916 (406) 086 081 075 068 100 100 08518 (457) 090 085 079 070 09024 (610) 100 096 088 077 10030 (762) 100 098 08436 (914) 100 091

gt48 (1219) 100

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 29: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

86 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 44 - Load adjustment factors for 12-in diameter threaded rods in uncracked concrete123

12-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 034 026 020 011 na na na na 010 005 003 002 021 011 007 004 na na na na2-12 (64) 059 059 057 054 040 030 022 013 055 053 053 052 018 009 006 004 035 018 012 007 na na na na

3 (76) 061 061 058 055 045 032 024 014 056 054 053 052 023 012 008 005 045 024 015 009 na na na na4 (102) 065 065 061 057 056 038 028 016 058 055 054 053 036 018 012 007 056 037 024 014 058 na na na5 (127) 068 068 064 058 069 043 032 019 060 057 055 054 050 026 017 010 069 043 033 020 065 na na na

5-34 (146) 071 071 066 060 080 048 035 021 062 058 056 054 061 032 021 012 080 048 039 025 069 056 na na6 (152) 072 072 067 060 083 049 036 021 063 058 056 054 065 034 022 013 083 049 040 026 071 057 na na7 (178) 076 076 069 062 097 056 041 024 065 059 057 055 082 042 028 016 097 056 044 032 077 061 na na

7-14 (184) 076 076 070 062 100 058 043 025 065 060 057 055 087 045 029 017 100 058 045 032 078 062 054 na8 (203) 079 079 072 063 064 047 027 067 061 058 056 100 052 034 020 064 048 034 082 066 057 na9 (229) 083 083 075 065 072 053 031 069 062 059 056 062 040 024 072 053 036 087 070 060 na10 (254) 086 086 078 067 080 059 034 071 063 060 057 072 047 028 080 059 039 092 073 064 na

11-14 (286) 091 091 081 069 090 066 039 074 065 061 058 086 056 034 090 066 042 097 078 067 05712 (305) 094 094 083 070 096 070 041 075 066 062 059 095 062 037 096 070 044 100 080 070 05914 (356) 100 100 089 073 100 082 048 079 069 064 060 100 078 047 100 082 049 087 075 06316 (406) 094 077 094 055 083 072 066 061 095 057 094 055 093 080 06818 (457) 100 080 100 062 088 074 068 063 100 068 100 062 098 085 07220 (508) 083 069 092 077 070 064 080 069 100 090 07622 (559) 087 076 096 080 072 066 092 076 094 07924 (610) 090 082 100 082 074 067 100 082 098 08330 (762) 100 100 090 080 071 100 100 09336 (914) 098 086 076 100

gt48 (1219) 100 098 084

Table 45 - Load adjustment factors for 12-in diameter threaded rods in cracked concrete123

12-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10 2-34 4-12 6 10(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 049 049 045 041 na na na na 010 006 004 003 021 012 009 005 na na na na2-12 (64) 059 059 057 054 055 055 050 044 055 054 053 052 018 010 007 004 035 020 015 009 na na na na

3 (76) 061 061 058 055 060 060 053 046 056 054 054 053 023 013 010 006 047 026 020 012 na na na na4 (102) 065 065 061 057 069 069 060 049 058 056 055 053 036 020 015 009 072 040 030 018 058 na na na5 (127) 068 068 064 058 079 079 067 053 061 057 056 054 050 028 021 013 100 056 042 025 065 na na na

5-34 (146) 071 071 066 060 088 088 073 056 062 058 057 055 062 035 026 016 070 052 031 070 057 na na6 (152) 072 072 067 060 090 090 075 057 063 059 057 055 066 037 028 017 074 056 033 071 059 na na7 (178) 076 076 069 062 100 100 083 062 065 060 058 056 083 047 035 021 094 070 042 077 063 na na

7-14 (184) 076 076 070 062 085 063 065 060 059 056 088 049 037 022 099 074 044 078 064 059 na8 (203) 079 079 072 063 091 066 067 061 059 057 100 057 043 026 100 086 051 082 068 062 na9 (229) 083 083 075 065 100 070 069 063 061 058 068 051 031 100 061 087 072 065 na10 (254) 086 086 078 067 075 071 064 062 058 080 060 036 072 092 076 069 na

11-14 (286) 091 091 081 069 081 074 066 063 059 095 071 043 081 097 080 073 06212 (305) 094 094 083 070 085 075 067 064 060 100 079 047 085 100 083 075 06414 (356) 100 100 089 073 095 079 070 067 062 099 060 095 090 081 06916 (406) 094 077 100 084 073 069 063 100 073 100 096 087 07318 (457) 100 080 088 076 071 065 087 100 092 07820 (508) 083 092 079 074 067 100 097 08222 (559) 087 096 082 076 069 100 08624 (610) 090 100 084 078 070 09030 (762) 100 093 086 075 10036 (914) 100 093 080

gt48 (1219) 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 30: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 87

328

325

326

327

324

324

324

323

Table 46 - Load adjustment factors for 58-in diameter threaded rods in uncracked concrete123

58-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 025 018 011 na na na na 009 004 003 001 019 008 006 003 na na na na3-18 (79) 059 059 057 054 044 030 022 013 056 054 053 052 022 010 007 004 044 020 013 007 na na na na

4 (102) 062 062 059 055 052 033 025 014 058 055 053 052 032 015 010 005 052 029 019 010 na na na na4-58 (117) 063 063 060 056 059 036 027 016 059 055 054 053 040 018 012 006 059 036 024 013 060 na na na

5 (127) 065 065 061 057 063 038 028 016 060 056 054 053 045 021 013 007 063 038 027 014 063 na na na6 (152) 068 068 063 058 076 042 031 018 062 057 055 053 059 027 018 009 076 042 035 019 069 na na na7 (178) 070 070 066 059 086 047 034 020 064 058 056 054 075 034 022 012 088 047 038 024 074 na na na

7-18 (181) 071 071 066 060 087 047 035 020 064 058 056 054 077 035 023 012 090 047 038 024 075 057 na na8 (203) 073 073 068 061 095 052 038 022 066 059 057 055 091 041 027 014 100 052 041 029 079 061 na na9 (229) 076 076 070 062 100 057 042 025 068 060 058 055 100 050 032 017 057 045 032 084 065 056 na

10 (254) 079 079 072 063 064 047 027 070 062 059 056 058 038 020 064 048 034 089 068 059 na11 (279) 082 082 074 065 070 052 030 072 063 060 056 067 043 023 070 052 036 093 071 062 na12 (305) 085 085 077 066 077 056 033 074 064 060 057 076 050 026 077 056 038 097 075 065 na14 (356) 091 091 081 069 089 066 038 077 066 062 058 096 062 033 089 066 041 100 081 070 05716 (406) 097 097 086 071 100 075 044 081 069 064 059 100 076 041 100 075 046 086 075 06118 (457) 100 100 090 074 084 049 085 071 066 060 091 049 084 050 091 079 06420 (508) 094 077 094 055 089 073 067 061 100 057 094 055 096 083 06822 (559) 099 079 100 060 093 075 069 063 066 100 060 100 087 07124 (610) 100 082 066 097 078 071 064 075 066 091 07426 (660) 085 071 100 080 073 065 084 071 095 07728 (711) 087 077 082 074 066 094 077 099 08030 (762) 090 082 085 076 067 100 082 100 08336 (914) 098 099 092 081 071 099 091

gt48 (1219) 100 100 100 092 077 100 100

Table 47 - Load adjustment factors for 58-in diameter threaded rods in cracked concrete123

58-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12 3-18 5-58 7-12 12-12(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 046 046 043 040 na na na na 009 004 003 002 019 009 006 004 na na na na3-18 (79) 059 059 057 054 055 055 050 044 056 054 053 052 022 010 007 004 045 020 015 009 na na na na

4 (102) 062 062 059 055 062 062 055 046 058 055 054 053 033 015 011 006 065 030 022 013 na na na na4-58 (117) 063 063 060 056 066 066 058 048 059 055 054 053 040 018 013 008 081 037 027 016 060 na na na

5 (127) 065 065 061 057 069 069 060 049 060 056 055 053 045 021 015 009 091 041 030 018 063 na na na6 (152) 068 068 063 058 077 077 066 053 062 057 056 054 060 027 020 012 100 054 040 024 069 na na na7 (178) 070 070 066 059 086 086 072 056 064 058 057 055 075 034 025 015 068 050 030 074 na na na

7-18 (181) 071 071 066 060 087 087 073 056 064 058 057 055 077 035 026 015 070 051 031 075 058 na na8 (203) 073 073 068 061 095 095 078 059 066 059 058 055 092 042 030 018 084 061 037 079 061 na na9 (229) 076 076 070 062 100 100 085 062 068 060 058 056 100 050 036 022 100 073 044 084 065 058 na

10 (254) 079 079 072 063 091 066 070 062 059 057 058 043 026 100 085 051 089 068 061 na11 (279) 082 082 074 065 098 069 072 063 060 057 067 049 029 098 059 093 072 064 na12 (305) 085 085 077 066 100 073 074 064 061 058 077 056 034 100 067 097 075 067 na14 (356) 091 091 081 069 081 078 066 063 059 097 071 042 081 100 081 073 06116 (406) 097 097 086 071 089 082 069 065 061 100 086 052 089 086 078 06618 (457) 100 100 090 074 097 085 071 067 062 100 062 097 092 082 07020 (508) 094 077 100 089 073 069 063 072 100 097 087 07322 (559) 099 079 093 076 071 065 083 100 091 07724 (610) 100 082 097 078 073 066 095 095 08026 (660) 085 100 080 075 067 100 099 08428 (711) 087 083 076 069 100 08730 (762) 090 085 078 070 09036 (914) 098 092 084 074 098

gt48 (1219) 100 100 095 082 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 31: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

88 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 48 - Load adjustment factors for 34-in diameter threaded rods in uncracked concrete123

34-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 033 024 018 010 na na na na 009 003 002 001 017 007 005 002 na na na na3-34 (95) 059 059 057 054 049 030 022 013 057 054 053 052 027 011 007 003 049 022 014 007 na na na na

4 (102) 060 060 057 054 051 031 023 013 057 054 053 052 029 012 008 004 051 024 016 008 na na na na5 (127) 062 062 059 056 060 034 025 015 059 055 054 052 041 017 011 005 060 033 022 011 na na na na

5-14 (133) 063 063 060 056 063 035 026 015 060 055 054 052 044 018 012 006 063 035 023 011 062 na na na6 (152) 065 065 061 057 069 038 028 016 061 056 055 053 054 022 014 007 072 038 029 014 066 na na na7 (178) 067 067 063 058 076 041 030 018 063 057 055 053 068 028 018 009 084 041 034 018 072 na na na8 (203) 069 069 065 059 083 045 033 019 065 058 056 054 083 034 022 011 096 045 037 021 077 na na na

8-12 (216) 071 071 066 059 087 047 035 020 066 059 056 054 091 037 024 012 100 047 038 024 079 059 na na9 (229) 072 072 067 060 090 049 036 021 067 059 057 054 099 040 026 013 049 039 026 081 060 na na

10 (254) 074 074 069 061 098 053 039 023 068 060 058 055 100 047 031 015 053 042 030 086 064 na na10-34 (273) 076 076 070 062 100 057 042 025 070 061 058 055 053 034 017 057 044 032 089 066 057 na

12 (305) 079 079 072 063 064 047 027 072 062 059 056 062 040 020 064 048 034 094 070 060 na14 (356) 084 084 076 066 074 055 032 076 064 061 057 078 051 025 074 055 037 100 075 065 na16 (406) 089 089 080 068 085 062 037 079 066 062 058 096 062 030 085 062 040 080 070 na

16-34 (425) 091 091 081 069 089 065 038 081 067 063 058 100 067 033 089 065 041 082 071 05618 (457) 094 094 083 070 095 070 041 083 068 064 058 074 036 095 070 043 085 074 05820 (508) 099 099 087 072 100 078 046 087 070 065 059 087 042 100 078 047 090 078 06122 (559) 100 100 091 074 086 050 091 072 067 060 100 049 086 050 094 082 06424 (610) 094 077 093 055 094 074 068 061 056 093 055 099 085 06726 (660) 098 079 100 059 098 076 070 062 063 100 059 100 089 07028 (711) 100 081 064 100 078 071 063 070 064 092 07330 (762) 083 068 080 073 064 078 068 095 07536 (914) 090 082 086 077 067 100 082 100 082

gt48 (1219) 100 100 099 086 073 100 095

Table 49 - Load adjustment factors for 34-in diameter threaded rods in cracked concrete123

34-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15 3-12 6-34 9 15(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 044 044 042 039 na na na na 009 003 002 001 017 007 005 003 na na na na3-34 (95) 059 059 057 054 055 055 050 044 057 054 053 052 027 011 007 004 054 022 015 009 na na na na

4 (102) 060 060 057 054 057 057 051 044 057 054 053 052 030 012 008 005 059 024 016 010 na na na na5 (127) 062 062 059 056 063 063 056 047 059 055 054 053 041 017 011 007 083 034 022 013 na na na na

5-14 (133) 063 063 060 056 064 064 057 047 060 055 054 053 045 018 012 007 089 036 024 014 062 na na na6 (152) 065 065 061 057 069 069 060 049 061 056 055 053 054 022 015 009 100 044 029 018 067 na na na7 (178) 067 067 063 058 076 076 065 052 063 057 055 054 069 028 019 011 056 037 022 072 na na na8 (203) 069 069 065 059 083 083 070 055 065 058 056 054 084 034 023 014 068 045 027 077 na na na

8-12 (216) 071 071 066 059 087 087 072 056 066 059 057 055 092 037 025 015 075 050 030 079 059 na na9 (229) 072 072 067 060 090 090 075 057 067 059 057 055 100 041 027 016 082 054 032 082 061 na na

10 (254) 074 074 069 061 098 098 080 060 069 060 058 055 048 032 019 095 063 038 086 064 na na10-34 (273) 076 076 070 062 100 100 084 062 070 061 058 056 053 035 021 100 070 042 089 066 058 na

12 (305) 079 079 072 063 091 066 072 062 059 057 063 042 025 083 050 094 070 061 na14 (356) 084 084 076 066 100 072 076 064 061 058 079 052 031 100 063 100 076 066 na16 (406) 089 089 080 068 078 080 066 062 059 097 064 038 077 081 070 na

16-34 (425) 091 091 081 069 081 081 067 063 059 100 068 041 081 083 072 06118 (457) 094 094 083 070 085 083 068 064 060 076 046 085 086 075 06320 (508) 099 099 087 072 091 087 070 065 061 089 054 091 090 079 06622 (559) 100 100 091 074 098 091 072 067 062 100 062 098 095 082 07024 (610) 094 077 100 094 074 069 063 070 100 099 086 07326 (660) 098 079 098 076 070 064 079 100 090 07628 (711) 100 081 100 079 072 065 089 093 07830 (762) 083 081 073 066 099 096 08136 (914) 090 087 078 070 100 100 089

gt48 (1219) 100 099 087 076 100

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 32: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 89

328

325

326

327

324

324

324

323

Table 50 - Load adjustment factors for 78-in diameter threaded rods in uncracked concrete123

78-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 023 017 010 na na na na 009 003 002 001 018 005 004 002 na na na na4-38 (111) 059 059 057 054 055 030 022 013 058 054 053 052 035 011 007 003 060 022 014 007 na na na na

5 (127) 060 060 058 055 058 032 023 014 059 054 053 052 043 013 009 004 066 027 017 008 na na na na5-12 (140) 061 061 059 055 061 033 024 014 060 055 054 052 050 015 010 005 072 031 020 009 065 na na na

6 (152) 063 063 060 056 064 034 026 015 061 055 054 052 057 017 011 005 078 034 023 011 068 na na na7 (178) 065 065 061 057 069 037 028 016 063 056 055 053 071 022 014 007 091 037 029 013 073 na na na8 (203) 067 067 063 058 075 041 030 018 065 057 055 053 087 027 017 008 100 041 034 016 078 na na na9 (229) 069 069 064 059 081 044 032 019 067 058 056 054 100 032 021 010 044 036 019 083 na na na

9-78 (251) 071 071 066 059 086 047 035 020 069 059 056 054 037 024 011 047 038 022 087 059 na na10 (254) 071 071 066 060 087 047 035 020 069 059 057 054 038 024 011 047 038 023 087 059 na na11 (279) 073 073 067 060 093 051 037 022 071 060 057 054 043 028 013 051 041 026 091 062 na na12 (305) 075 075 069 061 100 054 040 023 073 060 058 055 049 032 015 054 043 030 095 065 na na

12-12 (318) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 097 066 057 na14 (356) 079 079 072 063 063 047 027 077 062 059 055 062 040 019 063 048 034 100 070 060 na16 (406) 083 083 075 065 073 053 031 080 064 060 056 076 049 023 073 053 036 075 065 na18 (457) 088 088 079 067 082 060 035 084 066 062 057 091 059 027 082 060 039 079 068 na

19-12 (495) 091 091 081 069 088 065 038 087 067 063 058 100 066 031 088 065 041 082 071 05520 (508) 092 092 082 069 091 067 039 088 067 063 058 069 032 091 067 042 083 072 05622 (559) 096 096 085 071 100 073 043 092 069 064 059 080 037 100 073 045 087 076 05924 (610) 100 100 088 073 100 080 047 096 071 066 059 091 042 080 048 091 079 06126 (660) 091 075 087 051 099 073 067 060 100 048 087 051 095 082 06428 (711) 094 077 093 055 100 074 068 061 053 093 055 099 085 06630 (762) 098 079 100 059 076 070 062 059 100 059 100 088 06836 (914) 100 084 070 081 073 064 077 070 097 075

gt48 (1219) 096 094 092 081 069 100 094 100 087

Table 51 - Load adjustment factors for 78-in diameter threaded rods in cracked concrete123

78-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12 3-12 7-78 10-12 17-12(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 043 043 041 038 na na na na 009 003 002 001 018 006 004 002 na na na na4-38 (111) 059 059 057 054 055 055 050 044 058 054 053 052 036 011 008 005 071 022 016 010 na na na na

5 (127) 060 060 058 055 058 058 052 045 060 054 054 053 043 013 010 006 087 027 019 012 na na na na5-12 (140) 061 061 059 055 061 061 054 046 061 055 054 053 050 015 011 007 100 031 022 013 065 na na na

6 (152) 063 063 060 056 064 064 056 047 061 055 054 053 057 018 013 008 035 025 015 068 na na na7 (178) 065 065 061 057 069 069 060 049 063 056 055 054 072 022 016 010 044 032 019 073 na na na8 (203) 067 067 063 058 075 075 064 052 065 057 056 054 088 027 020 012 054 039 024 078 na na na9 (229) 069 069 064 059 081 081 068 054 067 058 056 055 100 032 023 014 065 047 028 083 na na na

9-78 (251) 071 071 066 059 086 086 072 056 069 059 057 055 037 027 016 074 054 032 087 059 na na10 (254) 071 071 066 060 087 087 073 056 069 059 057 055 038 027 016 076 055 033 087 059 na na11 (279) 073 073 067 060 093 093 077 059 071 060 058 056 044 032 019 087 063 038 092 062 na na12 (305) 075 075 069 061 100 100 082 061 073 060 058 056 050 036 022 100 072 043 096 065 na na

12-12 (318) 076 076 070 062 084 062 074 061 059 056 053 038 023 100 077 046 098 066 059 na14 (356) 079 079 072 063 091 066 077 062 060 057 063 045 027 091 054 100 070 063 na16 (406) 083 083 075 065 100 071 081 064 061 058 077 055 033 100 067 075 067 na18 (457) 088 088 079 067 076 084 066 063 059 091 066 040 076 079 071 na

19-12 (495) 091 091 081 069 080 087 067 064 060 100 075 045 080 082 074 06220 (508) 092 092 082 069 082 088 067 064 060 077 046 082 084 075 06322 (559) 096 096 085 071 087 092 069 065 061 089 054 087 088 079 06624 (610) 100 100 088 073 093 096 071 067 062 100 061 093 092 082 06926 (660) 091 075 099 100 073 068 063 069 099 095 086 07228 (711) 094 077 100 100 074 070 064 077 100 099 089 07530 (762) 098 079 076 071 065 085 100 092 07736 (914) 100 084 081 075 068 100 100 085

gt48 (1219) 096 092 084 074 098

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 33: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

90 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Table 52 - Load adjustment factors for 1-in diameter threaded rods in uncracked concrete123

1-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 036 022 017 010 na na na na 008 002 001 001 015 005 003 001 na na na na5 (127) 059 059 057 054 055 030 022 013 059 054 053 052 037 011 007 003 061 022 014 007 na na na na6 (152) 061 061 058 055 060 032 024 014 060 055 053 052 048 014 009 004 070 029 019 009 na na na na

6-14 (159) 061 061 059 055 061 033 024 014 061 055 054 052 051 015 010 005 073 030 020 009 065 na na na7 (178) 063 063 060 056 064 035 026 015 062 055 054 052 061 018 012 005 082 035 023 011 069 na na na8 (203) 065 065 061 057 069 038 028 016 064 056 055 053 074 022 014 007 093 038 029 013 074 na na na9 (229) 066 066 063 058 074 040 030 017 065 057 055 053 089 026 017 008 100 040 033 016 078 na na na

10 (254) 068 068 064 058 079 043 032 019 067 058 056 053 100 031 020 009 043 035 019 083 na na na11 (279) 070 070 065 059 085 046 034 020 069 058 056 054 035 023 011 046 037 021 087 na na na

11-14 (286) 071 071 066 059 086 047 034 020 069 059 056 054 037 024 011 047 038 022 088 058 na na12 (305) 072 072 067 060 090 049 036 021 070 059 057 054 040 026 012 049 039 024 091 060 na na13 (330) 074 074 068 061 096 052 038 022 072 060 057 054 046 030 014 052 041 028 094 063 na na14 (356) 076 076 069 062 100 056 041 024 074 061 058 055 051 033 015 056 044 031 098 065 na na

14-14 (362) 076 076 070 062 057 042 024 074 061 058 055 052 034 016 057 044 032 099 066 057 na16 (406) 079 079 072 063 064 047 027 077 062 059 055 062 040 019 064 048 034 100 070 060 na18 (457) 083 083 075 065 072 052 031 081 064 060 056 074 048 022 072 052 036 074 064 na20 (508) 086 086 078 067 080 058 034 084 065 061 057 087 056 026 080 058 038 078 067 na22 (559) 090 090 081 068 087 064 038 088 067 063 058 100 065 030 087 064 041 082 071 na

22-14 (565) 091 091 081 069 088 065 038 088 067 063 058 066 031 088 065 041 082 071 05524 (610) 094 094 083 070 095 070 041 091 068 064 058 074 035 095 070 043 085 074 05726 (660) 097 097 086 072 100 076 044 094 070 065 059 084 039 100 076 046 089 077 06028 (711) 100 100 089 073 082 048 098 071 066 060 094 043 082 049 092 080 06230 (762) 092 075 087 051 100 073 067 060 100 048 087 051 095 083 06436 (914) 100 080 100 062 077 070 062 063 100 062 100 091 070

gt48 (1219) 090 082 086 077 066 098 082 100 081

Table 53 - Load adjustment factors for 1-in diameter threaded rods in cracked concrete123

1-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20 4 9 12 20(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 042 042 040 038 na na na na 008 002 002 001 015 005 003 002 na na na na5 (127) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 015 009 na na na na6 (152) 061 061 058 055 060 060 053 046 060 055 054 053 049 014 010 006 097 029 019 012 na na na na

6-14 (159) 061 061 059 055 061 061 054 046 061 055 054 053 052 015 010 006 100 031 021 012 066 na na na7 (178) 063 063 060 056 064 064 057 047 062 055 054 053 061 018 012 007 036 024 015 069 na na na8 (203) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 015 009 044 030 018 074 na na na9 (229) 066 066 063 058 074 074 064 051 065 057 055 054 089 026 018 011 053 036 021 079 na na na

10 (254) 068 068 064 058 079 079 067 053 067 058 056 054 100 031 021 013 062 042 025 083 na na na11 (279) 070 070 065 059 085 085 071 055 069 058 056 055 036 024 014 072 048 029 087 na na na

11-14 (286) 071 071 066 059 086 086 072 056 069 059 057 055 037 025 015 074 050 030 088 059 na na12 (305) 072 072 067 060 090 090 075 057 071 059 057 055 041 027 016 082 055 033 091 061 na na13 (330) 074 074 068 061 096 096 079 059 072 060 058 055 046 031 019 092 062 037 095 063 na na14 (356) 076 076 069 062 100 100 083 062 074 061 058 056 051 035 021 100 069 042 098 065 na na

14-14 (362) 076 076 070 062 084 062 074 061 058 056 053 036 021 071 043 099 066 058 na16 (406) 079 079 072 063 091 066 077 062 059 057 063 042 025 085 051 100 070 061 na18 (457) 083 083 075 065 100 070 081 064 061 058 075 050 030 100 061 074 065 na20 (508) 086 086 078 067 075 084 065 062 058 088 059 035 071 078 069 na22 (559) 090 090 081 068 080 088 067 063 059 100 068 041 080 082 072 na

22-14 (565) 091 091 081 069 080 088 067 063 059 069 042 080 082 072 06124 (610) 094 094 083 070 085 091 068 064 060 078 047 085 086 075 06326 (660) 097 097 086 072 090 095 070 065 061 088 053 090 089 078 06628 (711) 100 100 089 073 095 098 071 066 062 098 059 095 092 081 06830 (762) 092 075 100 100 073 068 063 100 065 100 096 084 07136 (914) 100 080 077 071 065 086 100 092 078

gt48 (1219) 090 087 078 070 100 100 090

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 34: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 91

328

325

326

327

324

324

324

323

Table 54 - Load adjustment factors for 1-14-in diameter threaded rods in uncracked concrete123

1-14-inuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 035 023 016 009 na na na na 005 002 001 001 011 003 002 002 na na na na6-14 (159) 059 059 057 054 055 031 022 013 059 054 053 052 037 011 007 003 063 022 014 007 na na na na

7 (178) 060 060 058 055 058 033 023 014 060 054 053 052 043 013 008 004 069 026 017 008 na na na na8 (203) 062 062 059 055 062 035 025 014 061 055 054 052 053 016 010 005 078 031 020 010 066 na na na9 (229) 063 063 060 056 065 037 026 015 062 055 054 052 063 019 012 006 087 037 024 011 070 na na na

10 (254) 065 065 061 057 069 039 028 016 064 056 055 053 074 022 014 007 097 039 029 013 074 na na na11 (279) 066 066 062 057 073 041 029 017 065 057 055 053 086 025 016 008 100 041 033 015 078 na na na12 (305) 068 068 063 058 077 044 031 018 066 057 055 053 098 029 019 009 044 035 017 081 na na na13 (330) 069 069 064 059 082 046 033 019 068 058 056 054 100 033 021 010 046 036 020 084 na na na14 (356) 070 070 066 059 086 049 034 020 069 059 056 054 036 024 011 049 038 022 087 058 na na

14-14 (362) 071 071 066 060 087 049 035 020 069 059 056 054 037 024 011 049 038 023 088 059 na na15 (381) 072 072 067 060 090 051 036 021 070 059 057 054 040 026 012 051 039 024 091 060 na na16 (406) 073 073 068 061 095 054 038 022 072 060 057 054 045 029 013 054 041 027 094 062 na na17 (432) 075 075 069 061 099 056 040 023 073 060 058 055 049 032 015 056 043 029 096 064 na na18 (457) 076 076 070 062 100 060 042 025 075 061 058 055 053 035 016 060 044 032 099 066 057 na20 (508) 079 079 072 063 066 047 027 077 062 059 055 062 040 019 066 048 034 100 070 060 na22 (559) 082 082 074 065 073 051 030 080 063 060 056 072 047 022 073 051 036 073 063 na24 (610) 085 085 077 066 080 056 033 083 065 061 057 082 053 025 080 056 037 076 066 na26 (660) 088 088 079 067 086 061 036 086 066 062 057 092 060 028 086 061 039 079 069 na28 (711) 091 091 081 069 093 065 038 088 067 063 058 100 067 031 093 065 041 082 071 05530 (762) 094 094 083 070 100 070 041 091 068 064 058 074 035 100 070 043 085 074 05736 (914) 100 100 090 074 100 084 049 099 072 066 060 098 045 100 084 050 094 081 063

gt48 (1219) 100 082 100 066 100 079 072 063 100 070 100 066 100 094 072

Table 55 - Load adjustment factors for 1-14-in diameter threaded rods in cracked concrete123

1-14-incracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Embedmenthef

in 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 15 25 5 11-14 11-14 25(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (286) (635)

Spacing(s)Edg

edistance(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m)

1-34 (44) na na na na 040 040 039 037 na na na na 005 002 001 001 011 003 002 001 na na na na6-14 (159) 059 059 057 054 055 055 050 044 059 054 053 052 037 011 007 004 074 022 014 008 na na na na

7 (178) 060 060 058 055 058 058 052 045 060 054 053 052 044 013 008 005 088 026 017 009 na na na na8 (203) 062 062 059 055 062 062 055 046 061 055 054 052 054 016 010 006 100 032 021 011 066 na na na9 (229) 063 063 060 056 065 065 057 048 062 055 054 053 064 019 012 007 038 025 014 070 na na na

10 (254) 065 065 061 057 069 069 060 049 064 056 055 053 075 022 014 008 044 029 016 074 na na na11 (279) 066 066 062 057 073 073 063 051 065 057 055 053 086 026 017 009 051 033 018 078 na na na12 (305) 068 068 063 058 077 077 066 053 066 057 055 054 098 029 019 010 058 038 021 081 na na na13 (330) 069 069 064 059 082 082 069 054 068 058 056 054 100 033 021 012 066 043 024 085 na na na14 (356) 070 070 066 059 086 086 072 056 069 059 056 054 037 024 013 073 048 026 088 058 na na

14-14 (362) 071 071 066 060 087 087 073 056 070 059 057 054 038 025 014 075 049 027 089 059 na na15 (381) 072 072 067 060 090 090 075 057 071 059 057 055 041 026 015 082 053 029 091 061 na na16 (406) 073 073 068 061 095 095 078 059 072 060 057 055 045 029 016 090 058 032 094 063 na na17 (432) 075 075 069 061 099 099 081 061 073 060 058 055 049 032 018 098 064 035 097 064 na na18 (457) 076 076 070 062 100 100 085 062 075 061 058 056 054 035 019 100 070 038 099 066 057 na20 (508) 079 079 072 063 091 066 077 062 059 056 063 041 023 082 045 100 070 061 na22 (559) 082 082 074 065 098 069 080 063 060 057 072 047 026 094 052 073 063 na24 (610) 085 085 077 066 100 073 083 065 061 057 082 054 030 100 059 077 066 na26 (660) 088 088 079 067 077 086 066 062 058 093 060 033 067 080 069 na28 (711) 091 091 081 069 081 088 067 063 059 100 068 037 075 083 072 05930 (762) 094 094 083 070 085 091 068 064 059 075 041 083 086 074 06136 (914) 100 100 090 074 097 099 072 066 061 098 054 097 094 081 067

gt48 (1219) 100 082 100 100 079 072 065 100 084 100 100 094 077

1 Linear interpolation not permitted2Shadedareawithreducededgedistanceispermittedprovidedtheinstallationtorqueisreducedto030Tmaxfor5dlesle16-inandto05Tmax for s gt 16-in3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 35: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

92 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

32334 HIT-HY 200 with HIS-N Inserts

HIS-N internally threaded insert specifications38-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 711 ksi (490 MPa) and a minimum yield strength of 595 ksi (410 MPa)12- 58- and 34-in HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 667 ksi (460 MPa) and a minimum yield strength of 544 ksi (375 MPa)HIS-RNismanufacturedfromX5CrNiMo17122K700stainlesssteelconformingtoDINEN10088-3withaminimumtensilestrength of 1015 ksi (700 MPa) and a minimum yield strength of 508 ksi (350 MPa)

Perm

issi

ble

conc

rete

co

nditi

ons

Uncrackedconcrete

Dryconcrete

Perm

issi

ble

Dril

ling

Met

hod

Hammer drilling with carbide tipped drill bit

Crackedconcrete

Water saturatedconcrete

HiltiTE-CDorTE-YDHollowDrillBit

Figure 12 - HIS-N and HIS-RN internally threaded insert installation conditions

Figure 13 - HIS-N and HIS-RN specifications

Setting information Symbol UnitsThread size

38-16 UNC 12-13 UNC 58-11 UNC 34-10 UNCOutside diameter of insert in 065 081 100 109Nominal bit diameter do in 1116 78 1-18 1-14

Effectiveembedment hef

in 4-38 5 6-34 8-18(mm) (110) (125) (170) (205)

Thread engagementminimum

hs

in 38 12 58 34maximum in 1516 1-316 1-12 1-78

Installationtorque Tinst

ft-lb 15 30 60 100(Nm) (20) (40) (81) (136)

Concrete thickness hmin

in 59 67 91 106(mm) (150) (170) (230) (270)

Table 56 - HIS-N and HIS-RN specifications

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 36: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 93

328

325

326

327

324

324

324

323

Table 57 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete 12345678

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 7140 7820 9030 11060 15375 16840 19445 23815(111) (318) (348) (402) (492) (684) (749) (865) (1059)

12-13 UNC5 8720 9555 11030 13510 18785 20575 23760 29100

(127) (388) (425) (491) (601) (836) (915) (1057) (1294)

58-11 UNC6-34 13680 14985 17305 21190 29460 32275 37265 45645(171) (609) (667) (770) (943) (1310) (1436) (1658) (2030)

34-10 UNC8-18 18065 19790 22850 27985 38910 42620 49215 60275(206) (804) (880) (1016) (1245) (1731) (1896) (2189) (2681)

Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete bond failure for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete 123456789

Threadsize

Effective embedment

in (mm)

TensionmdashФNn or Nr ShearmdashФVn or Vr

ƒ´c = 2500 psi (172 Mpa)

lb (kN)

ƒ´c = 3000 psi (207 Mpa)

lb (kN)

ƒ´c = 4000 psi (276 Mpa)

lb (kN)

ƒ´c = 6000 psi (414 Mpa)

lb (kN)

ƒ´c = 2500 psi(172 Mpa)

lb (kN)

ƒ´c = 3000 psi(207 Mpa)

lb (kN)

ƒ´c = 4000 psi(276 Mpa)

lb (kN)

ƒ´c = 6000 psi(414 Mpa)

lb (kN)

38-16 UNC4-38 5055 5540 6145 6510 10890 11930 13235 14025(111) (225) (246) (273) (290) (484) (531) (589) (624)

12-13 UNC5 6175 6765 7815 9335 13305 14575 16830 20110

(127) (275) (301) (348) (415) (592) (648) (749) (895)

58-11 UNC6-34 9690 10615 12255 13210 20870 22860 26395 28450(171) (431) (472) (545) (588) (928) (1017) (1174) (1266)

34-10 UNC8-18 12795 14015 16185 17385 27560 30190 34860 37450(206) (569) (623) (720) (773) (1226) (1343) (1551) (1666)

1 See section 317 for explanation on development of load values2 See section 3173 to convert design strength (factored resistance) value to ASD value3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted4 Apply spacing edge distance and concrete thickness factors in tables 60 - 61 as necessary Compare to the steel values in table 59

The lesser of the values is to be used for the design5 Data is for temperature range A Max short term temperature = 104deg F (40deg C) max long term temperature = 75deg F (24deg C) FortemperaturerangeBMaxshorttermtemperature=176degF(80degC)maxlongtermtemperature=122degF(50degC)multiplyabovevalueby080 For temperature range C Max short term temperature = 248deg F (120deg C) max long term temperature = 162deg F (72deg C) multiply above value by 070 Short-term elevated concrete temperatures are those that occur over brief intervals eg as a result of diurnal cycling Long term concrete temperatures are roughly constant oversignificantperiodsoftime

6 Tabular values are for dry concrete conditions For water saturated concrete multiply design strength (factored resistance) by 0857 Tabular values are for short term loads only For sustained loads including overhead use see section 31758TabularvaluesarefornormalweightconcreteonlyForlightweightconcretemultiplydesignstrength(factoredresistance)byλa as follows Forsand-lightweightλa=051Forall-lightweightλa = 045

9TabularvaluesareforstaticloadsonlyForseismicloadsmultiplycrackedconcretetabularvaluesbyαseis = 060 See section 3174 for additional information on seismic applications

Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N and HIS-RN internally threaded inserts 12

Threadsize

ACI318AppendixDBasedDesign

ASTMA193B7 ASTMA193GradeB8Mstainless steel

Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5Tensile3

ϕNsalb (kN)

Shear 4ϕVsa

lb (kN)αseisV

5

38-16 UNC6300 3490

075540 3070

07(280) (155) (246) (137)

12-13 UNC11530 6385

0710145 5620

07(513) (284) (451) (250)

58-11 UNC18365 10170

0716160 8950

07(817) (452) (719) (398)

34-10 UNC27180 15055

0723915 13245

07(1209) (670) (1064) (589)

1 See section 3173 to convert design strength (factored resistance) value to ASD value2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements3Tensile=ϕAseN futa as noted in ACI 318 Appendix D4ShearvaluesdeterminedbystaticsheartestswithϕVsaleϕ060AseV futa as noted in ACI 318 Appendix D5 Reduction factor for seismic shear only See section 3174 for additional information on seismic applications

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 37: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

94 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

1 Linear interpolation not permitted2 Shadedareawithreducededgedistanceispermittedprovidedrebarhasnoinstallationtorque3 When combining multiple load adjustment factors (eg for a four-anchor pattern in a corner with thin concrete member) the design can become very

conservativeTooptimizethedesignuseHiltiPROFISAnchorDesignsoftwareorperformanchorcalculationusingdesignequationsfromACI318AppendixD4 Spacing factor reduction in shear ƒAVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒAV = ƒAN5 Concrete thickness reduction factor in shear ƒHVassumesaninfluenceofanearbyedgeIfnoedgeexiststhenƒHV = 10

Table 60 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in uncracked concrete123

HIS-N and HIS-RNall diametersuncracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 035 na na na 055 na na na 015 na na na 031 na na na na na na na

4 (102) 061 059 na na 039 038 na na 056 055 na na 021 019 na na 039 038 na na na na na na5 (127) 064 061 059 na 045 043 037 na 057 057 055 na 029 026 017 na 045 043 033 na na na na na

5-12 (140) 065 062 060 059 048 046 039 035 058 058 056 055 034 030 019 015 048 046 039 029 na na na na6 (152) 067 064 061 060 051 048 041 037 059 058 056 055 039 035 022 017 051 048 041 033 060 na na na7 (178) 070 066 063 062 059 054 045 040 060 060 057 056 049 043 028 021 059 054 045 040 064 062 na na8 (203) 072 068 065 063 067 061 049 043 062 061 058 057 060 053 034 026 067 061 049 043 069 066 na na9 (229) 075 070 066 065 076 069 054 046 063 062 059 058 071 063 040 031 076 069 054 046 073 070 na na10 (254) 078 073 068 067 084 076 058 050 065 064 060 058 083 074 047 036 084 076 058 050 077 074 064 na11 (279) 081 075 070 068 093 084 064 053 066 065 061 059 096 086 055 041 093 084 064 053 081 078 067 06112 (305) 084 077 072 070 100 091 070 057 068 066 062 060 100 098 062 047 100 091 070 057 084 081 070 06414 (356) 089 082 076 073 100 081 066 071 069 064 062 100 078 059 100 081 066 091 087 075 06916 (406) 095 086 079 077 093 076 074 072 066 063 096 073 093 076 097 094 080 07318 (457) 100 091 083 080 100 085 077 075 068 065 100 087 100 085 100 099 085 07824 (610) 100 094 090 100 085 083 074 070 100 100 100 099 09030 (762) 100 100 094 091 080 075 100 10036 (914) 100 099 086 080

gt48 (1219) 100 099 090

Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete123

HIS-N and HIS-RNall diameters

cracked concrete

Spacing factor in tension

ƒAN

Edgedistancefactor in tension

ƒRN

Spacing factor in shear 4

ƒAV

Edgedistanceinshear

Concrete thickness factor in shear 5

ƒHV

Toward edge

ƒRV

To edge

ƒRV

Thread Size in 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34 38 12 58 34Embedment

hef

in 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18 4-38 5 6-34 8-18(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)

Spacing(s)Edgedistanc(c

a) C

oncr

ete

thic

knes

s (h

) - i

n (m

m) 3-14 (83) 059 na na na 055 na na na 055 na na na 016 na na na 031 na na na na na na na

4 (102) 061 059 na na 060 055 na na 056 055 na na 021 019 na na 042 038 na na na na na na5 (127) 064 061 059 na 068 061 055 na 057 057 055 na 030 026 017 na 059 053 034 na na na na na

5-12 (140) 065 062 060 059 072 063 057 055 058 058 056 055 034 031 019 015 069 061 039 029 na na na na6 (152) 067 064 061 060 075 066 060 057 059 058 056 055 039 035 022 017 078 070 044 034 060 na na na7 (178) 070 066 063 062 084 072 064 062 060 060 057 056 049 044 028 021 098 088 056 042 064 062 na na8 (203) 072 068 065 063 092 079 069 066 062 061 058 057 060 054 034 026 100 100 068 052 069 066 na na9 (229) 075 070 066 065 100 085 074 071 063 062 059 058 072 064 041 031 100 100 082 062 073 070 na na10 (254) 078 073 068 067 092 079 075 065 064 060 058 084 075 048 036 095 072 077 074 064 na11 (279) 081 075 070 068 099 085 080 066 065 061 059 097 086 055 042 100 083 081 078 067 06112 (305) 084 077 072 070 100 090 085 068 066 062 060 100 098 063 048 095 084 081 070 06414 (356) 089 082 076 073 100 095 071 069 064 062 100 079 060 100 091 088 076 06916 (406) 095 086 079 077 100 074 072 066 064 097 073 097 094 081 07418 (457) 100 091 083 080 077 075 068 065 100 087 100 099 086 07824 (610) 100 094 090 086 083 074 070 100 100 099 09030 (762) 100 100 095 091 081 075 100 10036 (914) 100 099 087 080

gt48 (1219) 100 099 091

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 38: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 95

328

325

326

327

324

324

324

323

3234 Installation instructionsInstallation Instructions For Use (IFU) are included with each product package They can also be viewed or downloaded online atwwwushilticom(US)andwwwhiltica(Canada)BecauseofthepossibilityofchangesalwaysverifythatdownloadedIFUarecurrentwhenusedProperinstallationiscriticaltoachievefullperformanceTrainingisavailableonrequestContactHiltiTechnical Services for applications and conditions not addressed in the IFU

Figure 14 - HIT-HY 200 adhesive cure time and working time Resistance of cured Hilti HIT-HY 200 to chemicals

Chemical BehaviorAcetic acid 10 +Acetone bullAmmonia 5 +Benzylalcohol ndashChloric acid 10 bullChlorinated lime 10 +Citric acid 10 +Concrete plasticizer +De-icing salt (Calcium chloride) +

Demineralized water +Diesel fuel +Drilling dust suspension pH 132 +

Ethanol 96Ethylacetate ndashFormic acid 10 +Formwork oil +Gasoline +Glycole bullHydrogen peroxide 10 bullLactic acid 10 +Maschinery oil +Methylethylketon bullNitric acid 10 bullPhosphoric acid 10 +Potassium Hydroxide pH 132 +

Sea water +Sewage sludge +Sodium carbonate 10 10 +Sodium hypochlorite 2 2 +

Sulphuric acid 10 +30 +

Toluene bullXylene bull

Key ndash non-resistant + resistant bull limited resistance

Samples of the HIT-HY 200 adhesive were immersed in the various chemical compounds for up to one year At the end of the test period the samples were analyzed Any samples showing no visible damage and having less than a 25 reduction in bending (flexural) strength were classified as ldquoResistantrdquo Samples that had slight damage such as small cracks chips etc or reduction in bending strength of 25 or more were classified as ldquoLimited Resistancerdquo (ie exposed for 48 hours or less until chemical is cleaned up) Samples that were heavily damaged or destroyed were classified as ldquoNon-Resistantrdquo

Note In actual use the majority of the adhesive is encased in the base material leaving very little surface area exposed

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 39: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

96 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT-Z anchor rodDescription Bit dia (in) Min embed (in) Qty

HIT-Z 38 x 4 38 716 2-38 40HIT-Z 38 x 5 18 716 2-38 40HIT-Z 38 x 6 38 716 2-38 40HIT-Z 12 x 4 12 916 2-34 20HIT-Z 12 x 6 frac12 916 2-34 20HIT-Z 12 x 8 916 2-34 20 HIT-Z 58 x 6 34 3-34 12HIT-Z 58 x 8 34 3-34 12HIT-Z 58 x 9 12 34 3-34 12HIT-Z 34 x 8 12 78 4 6HIT-Z 34 x 9 frac34 78 4 6

HIT-HY 200-A (accelerated working time)Description Package contents Qty

HIT-HY 200-A (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-A Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-A Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 Manual Dispenser25

HIT-HY 200-A Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-A Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 Manual Dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-A cartridges 1

HIT-HY 200-R (regular working time)Description Package contents Qty

HIT-HY 200-R (111 fl oz330 ml) Includes(1)foilpackwith(1)mixerand38fillertubeperpack 1HIT-HY 200-R Master Carton (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpack 25HIT-HY 200-R Combo (111 fl oz330 ml) Includes(1)mastercartoncontaining(25)foilpackswith(1)mixerand38fillertubeperpackand

(1) HDM 500 manual dispenser25

HIT-HY 200-R Master Carton (169 fl oz500 ml) Includes(1)mastercartoncontaining(20)foilpackswith(1)mixerand38fillertubeperpack 20HIT-HY 200-R Combo (169 fl oz500 ml) Includes(2)mastercartonscontaining(20)foilpackseachwith(1)mixerand38fillertubeper

pack and (1) HDM 500 manual dispenser40

HIT-RE-M Static Mixer For use with HIT-HY 200-R cartridges 1

TE-CD Hollow Drill BitsOrder Description Working length (in)

Hollow Drill Bit TE-CD 12-13 8Hollow Drill Bit TE-CD 916-14 9-12Hollow Drill Bit TE-CD 58-14 9-12Hollow Drill Bit TE-CD 34-14 9-12Hollow Drill Bit TE-CD 16-A (Replacement collar)

TE-YD Hollow Drill BitsOrder Description Working Length (in)

Hollow Drill Bit TE-YD 34-24 15-12Hollow Drill Bit TE-YD 78-24 15-12Hollow Drill Bit TE-YD 1-24 15-12Hollow Drill Bit TE-YD 1 18-24 15-12 Hollow Drill Bit TE-YD 25-A (Replacement collar)

3235 Ordering information

HIT-HY 200-A HIT-HY 200-R

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 40: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 97

328

325

326

327

324

324

324

323

Threaded anchors for Hilti chemical anchor systems1

HAS-E Rods 58 steel HAS Super A193 B7 high strength steel HAS-R 304 stainless steel HAS-R 316 stainless steel

Description Qty Qty Description Qty Description Qty Description Qty

38 x 4-38 10 240 - - - - - -38x 5-18 20 200 38 x 5-18 20 38 x 5-18 20 38 x 5-18 2038 x 8 10 160 - - 38 x 8 10 - -38 x 12 10 90 - - - - 38 x 8 1012 x 3-18 10 240 - - - - - -12 x 4-12 10 160 - - - - - -12 x 6-12 20 160 12 x 6-12 20 12 x 6-12 20 12 x 6-12 2012x 8 10 120 - - 12 x 8 10 12 x 8 1012 x 10 10 120 - - 12 x 10 10 12 x 11 1012 x 12 10 80 - - - - 12 x 12 1058 x 8 20 80 58 x 7-58 20 58 x 7-58 20 58 x 7-58 2058 x 9 10 60 - - 58 x 10 10 58 x 9 1058 x 12 10 60 - - - - 58 x 12 1058 x 17 10 40 - - - - - -34 x 10 10 40 34 x 9-58 10 34 x 9-58 10 34 x 9-58 1034 x 11 10 30 - - - - 34 x 10 1034 x 12 10 30 - - 34 x 12 10 - -34 x 14 10 30 34 x 14 10 34 x 14 10 34 x 16 1034 x 17 10 20 - - 34 x 16 1034 x 19 10 20 - - - - - -34 x 21 10 20 - - - - - -34 x 25 10 20 - - - -78 x 10 10 20 78 x 10 HDG 5 78 x 10 10 78 x 10 10- - - 78 x 12 HDG 5 - - - -78 x 13 10 20 78 x 16 HDG 5 - - 78 x 16 101 x 12 4 16 1 x 12 4 1 x 12 4 1 x 12 41 x 14 2 16 1 x 14 2 - - - -1 x 16 2 12 1 x 16 2 - - 1 x 16 21 x 20 2 12 1 x 21 2 - - 1 x 20 21-14 x 16 4 8 1-14 x 16 4 - - - -1-14 x 22 4 8 1-14 x 23 4 - - - -

HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1

Description Useable thread length (in) Qty

38 x 4-14 1 1012 x 5 1-316 558 x 6-58 1-12 534 x 8-14 2 5

Hilti Rods are now stamped on the end to show grade of steel and overall anchor length

E=ISO898Class58Steel

B=ASTMA193GradeB7Steel

R1 = AISI 304 Stainless Steel

R2 = AISI 316 Stainless Steel

1 All dimensions in inches

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 41: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

98 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Accessories mdash DispensersBattery Powered

Description

HDE 500-A18 Compact Battery Dispenser Kit1 Includesdispenser(2)compactB1816-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Industrial Battery Dispenser Kit1 Includesdispenser(2)industrialB1833-AhLi-IonbatteriesC436batterychargerblackandredcartridge holders in a soft bag

+ + HDE 500-A18 Battery Dispenser Tool Body1 Includes black and red cartridge holders

Battery Charger C 436 Li-Ion 115V UsewithallB144B18batteriesorB36batteriesBattery Compact 18 16-Ah Li-IonBattery Industrial B 18 33-Ah Li-IonHDE 500-A18 Hard Case

ManualDescription

MD 1000 Manual Dispenser1 ForHITICE

HDM 500 Manual Dispenser with black foil pack holder Forusewith111floz330mland169floz500mlfoilpacksofHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500RE500-SDHIT-HY10PLUSHIT-HY70

HDM 500 Manual Dispenser with red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHY200-AandHY200-R

HDM 500 Manual Dispenser with black and red foil pack holder Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-A HIT-HY200-RHIT-HY150MAXHIT-HY150MAX-SDHIT-RE500HIT-RE500-SD HIT-HY 10 PLUS and HIT-HY 70 + +

HIT-CB 500 black cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpacksorHIT-HY150MAX HIT-HY150MAX-SDHIT-RE500HIT-RE500-SDHIT-HY10PLUSandHIT-HY70HIT-CR 500 red cartridge (foil pack) holder replacement Forusewith111floz330mland169floz500mlfoilpackadhesivesHIT-HY200-AandHIT-HY200-RHDM 500 Hard Case Only no tool

Pneumatic with 14 female compressed air coupling

Description

P 3500 Pneumatic Dispenser1 ForusewithHIT111floz330mland169floz500mlfoilpack

HIT-P 8000D Pneumatic Dispenser1 ForusewithHIT473floz1400mljumbofoilpack

P 3500 Cartridge (black foil pack) holder replacement For use with the P 3500 Pneumatic Dispenser and HIT-HY 150 MAX-SD HIT-HY 150 MAX HIT-RE500-SDHIT-RE500HIT-HY70andHIT-HY10PLUS

1 Dispensers not compatible with HIT-HY 200 Adhesive Anchor System

Color coded cartridge holders with the same quality dispenser With the introduction of HIT-HY 200 and Safe Settrade Technology Hilti has introduced a new chemistry with a 51 ratio All other Hilti adhesive anchor system have a 31 mix ratioThenewtechnologyallowsforbetterperformanceandboththeHDM500ManualDispensersandHDE500-A18BatteryDispenser can accept both cartridge ratios Simply change out the cartridge holder and you can use the dispenser on any jobsite with any Hilti foil pack adhesive

Red Black

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 42: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

HIT-HY 200 Adhesive Anchoring System 323

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 99

328

325

326

327

324

324

324

323

Hilti HIT Profi Accessories for blowing out drilled holesDescription Diameter in Length ft Qty

Blow-Out Pump For use in holes up to 10 in deep

1

Blow-Out Tool G 14 NPT InletFor use in holes up to 11 in deep Forholesdeeperthan11inuseBlow-OutToolplusthe following extensions

1

Extension hose for blow-out tool HIT-DL 1008 039 26 1Extension hose for blow-out tool HIT-DL 1608 071 26 1 38 Claw-type Quick Connect HIT-DL A 1Extension hose for HIT-DL A HIT-DL V101 039 33 1 Extension tube HIT-DL B (Rigidbent) 063 5Extension tube HIT-VL 1607 (Rigidstraight) 063 23 10Coupler for blowing extensions HIT-DL KMetal coupler for splicing 16 mm extension hose

063 10

Extension hose HIT-VL 16 (Flexible) 063 33 1HIT-DRS Dust Removal System with one hole for vacuum attachmentandanotherholefortheBlow-OutToolForuse with compressed air

1

Air nozzlesAttach to extension end for proper hole cleaning1

Description Qty

HIT-DL 12Use with 10 mm diameter hose

1

HIT-DL 916Use with 10 mm diameter hose

1

HIT-DL 1116Use with 10 mm diameter hose

1

HIT-DL 34Use with 16 mm diameter hosetube

1

HIT-DL 78Use with 16 mm diameter hosetube

1

HIT-DL 1Use with 16 mm diameter hosetube

1

HIT-DL 1-38Use with 16 mm diameter hosetube

1

1 HIT-DL size determined by the diameter of drilled hole see Accessory Selection Table below for proper sizing

Also avaliable in

metric

Hole diameter1 Description Description Use with hose dia Description

716 HIT-RB 716 - -12 HIT-RB 12 HIT-IP 12 9 mm HIT-DL 12916 HIT-RB 916 HIT-IP 916 9 mm HIT-DL 91658 HIT-RB 58 HIT-IP 58 9 mm -1116 HIT-RB 1116 HIT-IP 1116 9 mm HIT-DL 111634 HIT-RB 34 HIT-IP 34 16 mm HIT-DL 3478 HIT-RB 78 HIT-IP 78 16 mm HIT-DL 781 HIT-RB 1 HIT-IP 1 16 mm HIT-DL 11-18 HIT-RB 1 18 HIT-IP 1 18 16 mm -1-14 HIT-RB 1 14 HIT-IP 1 14 16 mm -1- 38 HIT-RB 1 38 HIT-IP 1 38 16 mm HIT-DL 1 381-12 HIT-RB 1 12 HIT-IP 1 12 16 mm -1-34 HIT-RB 1 34 HIT-IP 1 34 16 mm -

1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used2 AttachbrushtoHIT-RBHT-handleHIT-RBSorHIT-RBVextensions3 Use piston plugs to help prevent air voids during injection

Round brush2 Piston plug (10 pack)3 Air nozzle

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 43: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

323 HIT-HY 200 Adhesive Anchoring System

100 Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014

Hilti HIT Profi Accessories for brushing drilled holesManual brush handle for round steel brush

Description Qty

HIT-RBH (T-handle)Use to clean holes up to 11 in deep

1

Manual brush extension for round steel brush Description Qty

HIT-RBV 11 in extension for HIT-RBH (T-handle) 1

Holders for brush extension RBSConnectsRBSextensiontoyourHiltidrillforuseincleaningholes

Description Qty

TE-Y SDS Max connection 1TE-C SDS + Connection 1

Extensions for round steel brushesDescription Diameter in Length ft Qty

HIT-RBS 1007 039 23 1 HIT-RBS-10035 039 12 1

Hilti HIT Profi Accessories for adhesive injectionExtension hosesFor use in holes deeper than 10 in

Description Diameter in Length ft Qty

HIT-VL 910 flexible hose 035 33 10 HIT-VL 1607 rigid tube 063 23 10HIT-VL 16 flexible hose 063 33 1

Coupler for injection extensionsDescription Diameter in Qty

HIT-VL K Plastic coupler for connecting 16 mm (063 in) hoses and tubes

063 5

Overhead injection accessoriesDescription Hole Diameter in Qty

HIT-OHW overhead wedge 716 to 1-14 100HIT-OHC1 overhead drip guard 716 to 58 10HIT-OHC2 overhead drip guard 1116 to 1-14 10

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101

Page 44: 3.2.3 HIT-HY 200 Adhesive Anchoring System€¦ · Adhesive Anchoring Systems 3.2.3 HIT-HY 200 Adhesive Anchoring System  3 3 4 ...

Adhesive Anchoring Systems

Notes

Hilti Inc (US) 1-800-879-8000 | wwwushilticom I en espantildeol 1-800-879-5000 I Hilti (Canada) Corp 1-800-363-4458 I wwwhiltica I Anchor Fastening Technical Guide 2014 101