320 AMP CONTINUOUS 400 AMP MAX - Kirby...

3
320 AMP CONTINUOUS-4 TERMINAL-JAW CLAMPING LEVER-RINGLESS-600 VAC 320 AMP CONTINUOUS 400 AMP MAX '1; 3) @ ©C3y @ 2448 2124 U2124-X U2448-X 320 AMP-4 TERMINAL-SIDE WIREWAY-RINGLESS-103W SERVICE OH/UG UG CATALOG NUMBER U2448-X *U2124-X HUB C.P. C.P. CONNECTORS CU/AL LINE 3/8"-16 STUD 3/8"-16 STUD LOAD 3/8"-16 STUD 3/8"-16 STUD FFTH TERM. KTTB K3865 K3865 BY- R4SS LEVER LEVER DIMENSIONS D" 6 1 /2 5 3 /4 W" 17 3 /4 16 H 34 1 /s 30 CONCENTRIC K.O.'S 1 3'/2 2 3 3 1 / 2 3 4 4 4 1 /4 1 /4 5 V/4,1 6 V/4,1 HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: The lever supplies clamping action on meter spades and also operates bypass device. CONNECTORS: Stud type units supplied with 3/8"-16 hex head nuts with Belleville washers. For connector kits, order as extra: K1539 (350kcmil) or K1540 (BOOkcmil). For twin lug connectors order as extra: K1350 (350kcmil). Separate kits are required for both line and load. FIFTH TERMINAL: For factory installed fifth terminal in the 6 o'clock position add the suffix "-5T6" to the catalog number. For factory installed fifth terminal in the 9 o'clock position at the suffix "-5T9" to the catalog number. * For the same unit with anti-inversion feature order catalog number U1915-X. fll MILBANK 20

Transcript of 320 AMP CONTINUOUS 400 AMP MAX - Kirby...

Page 1: 320 AMP CONTINUOUS 400 AMP MAX - Kirby Riskkirbyrisk.com/woeb/datasheets/MILBANC00002_20_63_71.pdf320 AMP CONTINUOUS 400 AMP MAX ... to provide a degree of protection against rain,

320 AMP CONTINUOUS-4 TERMINAL-JAW CLAMPING LEVER-RINGLESS-600 VAC

320 AMP CONTINUOUS400 AMP MAX

' 1 ;3)

@©C3y@24482124

U2124-X U2448-X

320 AMP-4 TERMINAL-SIDE WIREWAY-RINGLESS-103W

SERVICE

OH/UG

UG

CATALOGNUMBER

U2448-X

*U2124-X

HUB

C.P.

C.P.

CONNECTORSCU/AL

LINE

3/8"-16STUD

3/8"-16STUD

LOAD

3/8"-16STUD

3/8"-16STUD

FFTHTERM.KTTB

K3865

K3865

BY-R4SS

LEVER

LEVER

DIMENSIONS

D"

61/2

53/4

W"

173/4

16

H

341/s

30

CONCENTRIC K.O.'S

1

3'/2

2

3

31/2

3

4

4

4

1/4

1/4

5

V/4,1

6

V/4,1

HUBS: For proper hub selection see the hub suffix chart on the accessory page.BYPASS: The lever supplies clamping action on meter spades and also operates bypass device.CONNECTORS: Stud type units supplied with 3/8"-16 hex head nuts with Belleville washers. For connector kits, order as extra:K1539 (350kcmil) or K1540 (BOOkcmil). For twin lug connectors order as extra: K1350 (350kcmil). Separate kits are requiredfor both line and load.FIFTH TERMINAL: For factory installed fifth terminal in the 6 o'clock position add the suffix "-5T6" to the catalog number. Forfactory installed fifth terminal in the 9 o'clock position at the suffix "-5T9" to the catalog number.

* For the same unit with anti-inversion feature order catalog number U1915-X.

fll MILBANK20

Page 2: 320 AMP CONTINUOUS 400 AMP MAX - Kirby Riskkirbyrisk.com/woeb/datasheets/MILBANC00002_20_63_71.pdf320 AMP CONTINUOUS 400 AMP MAX ... to provide a degree of protection against rain,

M E T E R S O C K E T A C C E S S O R I E S

INTERCHANGEABLE UNIT HUBS

REMOVABLE HUBCLOSING PLATE

SMALL"RL"OPENING (STANDARD)

LARGE "R"OPENING (HEAVY DUTY)

SIZE

STANDARD(for -RL opening)

LARGE(for -R opening)

SUFFIX

-XL

-X

CAT. #

A7551

S9064

SUFFIX

-WL-YL-ZL-DL-EL

SIZE

1"

1 V/'

1 V?"2"

21/2"

MILBANKNO.

A7514A7515A7516A7517A7518

I

SUFFIX

-F-G-H

SIZE

3"

3'2"

4"

MILBANKNO.

A8110

A8111A8112

' ID Oil

HUB ADAPTER PLATE(Converts -R opening to -RL)

S8324

HUB SUFFIX CHART

CLOSING COVERS

•\ /

ORLR

XLX

RXL

RRL

Plain TopSmall Hub OpeningLarge Hub OpeningSmall Closing PlateLarge Closing PlateLarge Hub Opening

adapted to small Closing Plate

Large Hub Openingadapted to small Hub Opening

WLYLZLDLEL

F

G

H

1"1 V/'

1V2"

2"2'/2"

3"

3V

4"

For -RL OpeningFor -RL OpeningFor -RL OpeningFor -RL OpeningFor -RL Opening

For -R Opening

For -R Opening

For -R Opening

METER CLOSING PLATE(Gray Plastic)

6003

METAL CLOSING PLATE(For ringless sockets)

CP-21

METER CLOSING PLATE(Clear Plastic)

6116 GO

HUBS FOR SWITCHES

CATALOGNUMBER

SH75

SH100

SH125

SH150

SIZE

y4"1"

1 v:1 1/2"

CATALOGNUMBER

LH125

LH150

LH200

LH250

SIZE

1 v:1 1/2"2"

2 1/2"

SINGLE

SINGLE CONNECTOR KITS

BREAKER MOUNTING CLIP(for RV/MH pedestals)

K3785

CONNECTOR KITS

For use with 3/8"-16 studtype units only

SUFFIX

-K1-K3

SUFFIX

-K5-K7

CATALOG #

K1539K1540

CATALOG #

K3082K3441

(3 per set) - 1 0

350 kcmil (MAX)600 kcmil (MAX)

(4 per set) - 3 0

350 kcmil (MAX)600 kcmil (MAX)

fll MILBANK

TWIN

TWIN CONNECTOR KITS

SUFFIX

-K2-K4

SUFFIX

-K6-K8

CATALOG #

K1350K1541

CATALOG #

K3442K3083

(3 per set) - 1 0

350 kcmil (MAX)600 kcmil (MAX)

(4 per set) -30

350 kcmil (MAX)600 kcmil (MAX)

63

Page 3: 320 AMP CONTINUOUS 400 AMP MAX - Kirby Riskkirbyrisk.com/woeb/datasheets/MILBANC00002_20_63_71.pdf320 AMP CONTINUOUS 400 AMP MAX ... to provide a degree of protection against rain,

P R O D U C T S P E C I F I C A T I O N S

ENCLOSURE INFORMATION

MILBANK ELECTRICAL METER ENCLOSURESSPECIFICATION NOTE

All Milbank electrical enclosures in this catalog are rated "Type 3R Electrical Enclosure" unless specified otherwise onpage (Type 1 switches are listed on page 8.) All enclosures with a U/L designation are constructed per the appropriateU/L standard and may be installed per the National Electric Code. Meter sockets are constructed per "UL 414, MeterSockets," file #E30202 and per "ANSI C12.7-1993-Meter Sockets." All test switches are constructed per "UL414, MeterSockets," file # E30202 and per "ANSI C12.9-1993-Test Switches." Power outlets are constructed per "UL 231, PowerOutlets," file # E90945. Panelboards are constructed per "UL 67, Panelboards," file # E32628 and "NEMA PB-1-1984-Panelboards." Pullout switches are constructed per "UL 1429, Pullout Switches," file # 133062.

DEFINITIONS PERTAINING TO NONHAZARDOUS LOCATIONS

INDOOR USE

TYPE 1 ENCLOSURE:Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against limited

amounts of falling dirt.

TYPE 12 ENCLOSURE:Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against circulating

dust, falling dirt and dripping noncorrosive liquids.

TYPE 13 ENCLOSURE:Type 13 enclosures are intended for indoor use primarily to provide a degree of protection against dust,

spraying of water, oil, and noncorrosive coolant.

OUTDOOR USE

TYPE 3 ENCLOSURE:Type 3 enclosures are intended for outdoor use primarily to provide a degree of protection against rain,

sleet, windblown dust, and damage from external ice formation.

TYPE 3R ENCLOSURE:Type 3R enclosures are intended for outdoor use primarily to provide a degree of protection against rain,

sleet, and damage from external ice formation.

TYPE 4 ENCLOSURE:Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against

wind-blown dust and rain, splashing water, hose-directed water, and damage from external ice formation.

TYPE 4X ENCLOSURE:Type 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection

against corrosion, wind-blown dust and rain, splashing water, hose-directed water, and damage from external ice for-mation.

fill MILBANK71