30RB/RQ 039S-160SAir-Cooled Liquid ChillerReversible Air-To-Water Heat Pump30RB: Nominal cooling capacity: 39.7-157.9kW30RQ: Nominal cooling capacity: 38.3-150.3kW Nominal heating capacity: 41.4-158.7kW
Carrier Corporation is a subsidiary of the United Technologies Corp. (UTC), which ranks the 150th in Fortune Top 500 in 2011 and has its operations in aerospace and building systems industries all over the world. From the time the founder Dr. Carrier invented the first system of modern air conditioning in 1902, Carrier has been the world leader in the air conditioning industry with its products and system solutions supplied to numerous famous buildings, and up to now, the network of distribution cover more than 170 countries all over the world. In 2011, Carrier ranked top in the HVAC industry field with its sales revenue of US $12 billion.
In China, there are 6 Carrier factories which have more than 2500 employees. As the world-class factory, Carrier has a number of technically advanced production lines, manufacturing commercial and residential chillers, compressors and air-side products. A wide range of products are able to meet diversified require-ments of different customers. The global R&D center located in Shanghai has the capability of developing several major projects in the same time, with many advanced technical patents awarded to support Carrier stay most competitive in terms of technology advantage in the HVAC industry.
Carrier China
In 1998, Time magazine named Dr. Carrier oneof its 20 most influential builders and titans ofthe 20thcentury.
Features
Benefits
Quiet operation
Economical operation
Increased energy efficiency at part load- The refrigerant circuit includes several compressors connected in parallel. At part load, around 99% of the operating time, only the compressors that are absolutely necessary operate. - The electronic expansion device (EXV) allows operation at a lower condensing pressure (EER, COP and ESEER optimization).- Dynamic superheat management for better utilization of the evaporator heat exchange surface.- Defrost cycle optimization (30RQ).Reduced maintenance costs- Maintenance-free scroll compressors.- Fast diagnosis of possible incidents and their history via the Pro-Dialog Plus control.- HFC-410A refrigerant is easier to use than other refrigerant blends.
3
The new generation of Aquasnap Puron liquid chillers/air-to-water heat pumps was designed for commercial (air conditioning of offices, hotels etc.) or industrial (low-temperature process chillers etc.) applications.
Standard unit with hydronic module including all necessary hydronic components, easy and fast installation to save time, space and money.Low operating sound with no intrusive low-frequency noise, creates a better working/living environment.Environment sound refrigerant HFC-410A of zero ozone depletion potential.Electronic expansion valve (EXV) utilization, several compressors connected in parallel lead to more economical operating cost.Exceptional endurance tests ensure superior reliability for minimizing chiller down-time.
Compressors- Low-noise scroll compressors with low vibration level.- The compressor assembly is installed on an independent chassis and supported by anti-vibration mountings.- Dynamic suction and discharge piping support,minimizing vibration transmission (Carrier patent).Condenser section- Vertical condenser coils.- Protection grilles on anti-vibration mountings to protect the heat exchanger against possible shocks.- Low-noise latest-generation Flying Bird IV fans (Carrier patent) , made of a composite material are now even quieter and do not generate intrusive low-frequency noise.- Rigid fan installation for reduced start-up noise (Carrier patent).
Environmental care
Superior reliability
4
Easy and fast installation
State-of-the-art concept- Cooperation with specialist laboratories and use of limit simulation tools (finite element calculations) for the design of the critical components, e.g. motor supports, suction/discharge piping etc.Exceptional endurance tests- Corrosion resistance tests in salt mist in the laboratory.- Accelerated ageing test on components that are submitted to continuous operation: compressor piping,fan supports.- Transport simulation test in the laboratory on a vibrating table.
Ozone-friendly HFC-410A refrigerant- Chlorine-free refrigerant of the HFC group with zero ozone depletion potential.- High-density refrigerant, therefore less refrigerant required.- Very efficient - gives an increased energy efficiency ratio.Leak-tight refrigerant circuit- Brazed refrigerant connections for increased leaktightness.- Reduction of leaks due to reduced vibration levels and elimination of capillary tubes (TXVs).- Verification of pressure transducers and temperature sensors without transferring refrigerant charge.
Integrated hydronic module - Centrifugal fixed speed water pump.- Single or dual pump (as required) with operating time balancing and automatic changeover to the back-up pump if a fault develops.- Water filter protecting the water pump against circulating debris.- High-capacity membrane expansion tank ensures pressurization of the water circuit.- Thermal insulation and frost protection down to -20 , using an electric resistance heater.Physical features- The unit has a small footprint and a low height (1330 mm) allowing it to blend in with any architectural styles.- The unit is enclosed by easily removable panels, covering all components (except condensers and fans).Simplified electrical connections- A single power supply point without neutral.- Main disconnect switch with high trip capacity.- Transformer for safe 24 V control circuit supply included.Fast commissioning- Systematic factory operation test before shipment.- Quick-test function for step-by-step verification of the instruments, electrical components and motors.
Pro-Dialog Plus combines intelligence with operating simplicity. The control constantly monitors all machine
parameters and precisely manages the operation of compressors, expansion devices, fans and of the evaporator
water pump for optimum energy efficiency.
5
Pro-Dialog Plus Control
User-friendly interface
The new backlighted LCD interface includes a manual control potentiometer to ensure legibility under any lighting conditions. The information
is in clear text and can be displayed in English.
Unit uses intuitive tree-structure menus, similar to the Internet navigators. They are user-friendly and permit quick access to the principal
operating parameters: number of compressors operating, suction/discharge pressure, compressor operating hours, set point, air temperature,
entering/leaving water temperature.
A quick test of all unit components and control points to verify the correct operation of every switch, circuit breaker, contactor etc. at the start
of the chiller.
Real-time monitor all the operation parameter, and alarm when necessary.
Control system is facilitated with RS485 serial communication port for remote diagnosis or special diagnosis tools.
Powerful diagnostics
Password protection in case of mishandling.
Unit is protected against: compressor reverse, low chilled water temperature, high/low refrigerant pressure, excessive current, motor overload.
Sufficient safety measures
Master/slave control of two chillers operating in parallel with operating time equalization and automatic changeover in case of a unit fault.
Communication with other Building Management System (BMS) by selecting BacNet/J-Bus/LonTalk gateway.
Group control
Unit provides different control mode including LOCAL/REMOTE/CCN.
Remote control function including: Unit ON/OFF, dual set point control, demand limit control, user safety interlock, water pump control,
operation indication, circuit alarm and alert etc.
Enable automatic reset of leaving water temperature according to return water temperature or outside air temperature to ensure optimum
energy efficiency.
Control algorithm prevents excessive compressor cycling and permits reduction of the water quantity in the hydronic circuit (Carrier patent).
Automatic compressor unloading in case of abnormally high condensing pressure. If an abnomal incident occurs (e.g. fouled condenser coil,
fan failure), Aquasnap continues to operate, but at reduced capacity.
Advanced control function
HFC-410A
Hermetic scroll compressors, 48.3r/s
Pro-Dialog Plus
Grooved copper tubes and aluminium fins
Axial Flying Bird IV with rotating shroud
Brazed plate heat exchanger
Pump, Victaulic screen safety valve,expansion tank,purge valves etc.
Horizontal single-stage centrifugal pump
Victaulic
400V-3Ph-50Hz
Via internal transformer
039S
39.7
13.0
2.88
488
514
458
8.5
-
2
-
2
50
1
3800
720
2.6
1.9
41
1000
227
223
12
400
DN50
28
35
115
0.8
1.3
1.3
060S
59.8
20.4
2.84
545
571
515
15.0
-
2
-
2
50
1
3800
720
4.0
2.9
60
1000
194
190
12
400
DN50
41
51
146
0.7
1.3
1.3
080S
80.5
27.1
2.80
562
588
533
15.5
-
2
-
2
50
1
5300
960
5.6
3.8
65
1000
196
191
12
400
DN50
58
68
212
1.6
1.8
1.8
100S
100.9
34.4
2.80
877
922
845
20.0
-
3
-
3
33
2
7600
720
9.9
4.8
55
1000
223
217
35
400
DN65
70
84
199
1.5
2.1
2.1
-
120S
118.0
41.7
2.73
912
960
876
25.0
3
-
3
33
2
7600
720
11.3
5.6
63
1000
201
194
35
400
DN65
86
99
243
1.5
2.3
2.3
160S
157.9
54.8
2.72
1114
1151
1075
16.0
16.0
2
2
4
25
2
10600
960
14.7
7.5
78
1000
181
168
35
400
DN65
116
136
280
3.2
4.7
4.7
kW
kW
kW/kW
kg
kg
kg
kg
kg
%
rpm
I
kPa
kPa
I
kPa
A
A
A
kW
kW
kW
l/s
I/s
kPa
kPa
6
Technical Specifications
* Nominal cooling mode - evaporator entering/leaving water temperature 12/7℃, outside air temperature 35℃;
Evaporator fouling factor 0.018m²K/kW.
30RB
Nominal cooling capacity*
Compressor power input
EER
Operating weight
Standard unit with fixed speed single pump
Unit with fixed speed dual pump
Unit without hydronic module
Refrigerant
Circuit A
Circuit B
Compressor
Circuit A
Circuit B
Number of capacity stages
Minimum capacity
Control
Condenser
Fans
Quantity
Total air flow
Fan speed
Evaporator
Water volume
Nominal water flow rate
Unit internal water pressure drop
Max. water-side operating pressure without hydronic module
Hydronic module
Water pump
Water head external to chiller
Single pump at nominal water flow rate
Dual pump at nominal water flow rate
Expansion tank
Max. water-side operating pressure with hydronic module
Water connection
Diameter
Electrical data
Main power supply
Control power supply
Nominal unit operating current draw
Maximum operating current draw
Maximum start-up current
Total fan power input
Pump power input (single pump)
Pump power input (dual pump)
Performance data
HFC-410A
Hermetic scroll compressors, 48.3r/s
Pro-Dialog Plus
Grooved cooper tubes and aluminium fins
Axial Flying Bird IV with rotating shroud
Brazed plate heat exchanger
Pump,Victaulic screen filter,safety valve,expansion tank,purgevalves etc.
Horizontal single-stage centrifugal pump
Victaulic
400V-3Ph-50Hz
Via internal transformer
30RQ
Nominal cooling capacity*
Compressor power input, cooling mode
EER
Nominal heating capacity*
Compressor power input, heating mode
COP
Operating weight
Standard unit with fixed speed single pump
Unit with fixed speed dual pump
Unit without hydronic module
Refrigerant
Circuit A
Circuit B
Compressor
Circuit A
Circuit B
Number of capacity stages
Minimum capacity
Control
Air heat exchanger
Fans
Quantity
Total air flow
Fan speed
Water heat exchanger
Water volume
Nominal water flow rate,cooling mode
Nominal water flow rate,heating mode
Nominal pressure drop, cooling mode
Nominal pressure drop, heating mode
Max. water-side operating pressure without hydronic module
Hydronic module
Water pump
Water head external to chiller
Single pump at nominal water flow rate,cooling mode
Dual pump at nominal water flow rate,cooling mode
Single pump at nominal water flow rate,heating mode
Dual pump at nominal water flow rate,heating mode
Expansion tank
Max. water-side operating pressure with hydronic module
Water connection
Diameter
Electrical data
Main power supply
Control power supply
Nominal unit operating current draw
Maximum operating current draw
Maximum start-up current
Total fan power input, cooling mode
Total fan power input, heating mode
Pump power input (single pump)
Pump power input (dual pump)
-
060S
58.6
19.2
2.80
61.3
18.0
3.09
582
608
552
17.5
2
-
2
50
1
5300
960
4.0
2.82.9
56
62
1000
209
205
205
200
12
400
DN50
43
53
148
1.7
1.9
1.4
1.4
12
078S
74.3
26.6
2.61
77.7
24.6
2.94
590
616
560
16.5
-
2
-
2
50
1
5300
960
5.6
3.5
3.7
52
61
1000
211
207
197
192
400
DN50
58
68
212
1.8
1.9
1.7
1.7
100S
99.0
33.3
2.84
101.4
30.5
3.15
935
980
903
28.5
-
3
-
3
33
2
7600
720
9.9
4.7
4.8
53
55
1000
223
217
219
213
35
400
DN65
70
84
199
1.5
1.8
2.1
2.1
120S
113.8
40.0
2.74
117.2
35.9
3.11
995
1043
959
33.0
-
3
-
3
33
2
7600
720
11.3
5.4
5.6
60
64
1000
205
198
193
185
35
400
DN65
86
99
243
1.5
1.8
2.4
2.4
039S
38.3
12.3
2.92
41.4
12.6
3.08
535
561
506
12.5
-
2
-
2
50
1
3800
720
2.6
2.0
38
45
1000
230
226
219
215
12
400
DN50
28
35
115
0.8
0.9
1.3
1.3
1.8
kW
kW
kW/kW
kW
kW
kW/kW
kg
kg
kg
kg
kg
%
rpm
I
l/s
kPa
kPa
kPa
I
kPa
A
A
A
kW
kW
kW
kW
kPa
kPa
kPa
kPa
l/s
I/s
Technical Specifications
7
160S
150.3
54.1
2.63
158.7
48.7
3.04
1117
1127
1078
18.5
18.5
2
2
4
25
2
10600
960
14.7
7.2
7.6
72
78
1000
188
176
176
163
35
400
DN65
116
136
280
3.1
3.5
4.6
4.6
* Nominal cooling mode - evaporator entering/leaving water temperature 12/7℃, outside air temperature 35℃;Nominal heating mode - water heat exchange entering/leaving water temperature 40/45℃, outside air temperature 7℃; Water heat exchanger fouling factor 0.018m²K/kW.
Performance data
8
Cooling Capacities, 30RB039S~160S
Legend:LWT leaving water temperatureCAP cooling capacityCOMP compressor power inputFLOW water flow
Application data:Standard units, refrigerant: HFC-410AEvaporator temperature rise: 5℃Fouling factor: 0.018 m²K/kW
Outside air temperature℃
CAP
kW
40.9
62.8
85.4
107.1
125.6
167.3
42.1
65.0
87.9
110.2
129.0
172.6
43.3
67.2
90.5
113.5
132.6
178.1
44.5
69.4
93.2
116.8
136.4
183.6
46.9
74.0
98.6
123.5
143.9
195.1
25
COMP
kW
10.7
16.4
23.4
27.8
34.3
45.2
10.8
16.5
23.6
28.2
35.1
45.9
10.9
16.6
23.8
28.6
35.8
46.7
11.1
16.8
24.1
29.0
36.2
47.5
11.3
17.1
24.6
29.9
37.1
48.5
FLOW
I/s
2.0
3.0
4.1
5.1
6.0
8.0
2.0
3.1
4.2
5.3
6.2
8.2
2.1
3.2
4.3
5.4
6.3
8.5
2.1
3.3
4.5
5.6
6.5
8.8
2.2
3.5
4.7
5.9
6.9
9.3
CAP
kW
39.2
59.9
80.7
101.6
118.9
158.2
40.4
62.1
83.1
104.6
122.2
163.2
41.5
64.2
85.6
107.7
125.5
168.4
42.7
66.4
88.0
110.7
128.8
173.5
45.1
70.7
93.2
117.0
136.0
184.4
30
COMP
kW
11.6
18.1
25.4
30.4
36.8
49.0
11.7
18.3
25.6
30.8
37.7
49.7
11.8
18.4
25.9
31.2
38.5
50.5
12.0
18.6
26.1
31.7
39.3
51.3
12.3
18.8
26.6
32.6
40.2
52.8
FLOW
I/s
1.9
2.9
3.9
4.9
5.7
7.6
1.9
3.0
4.0
5.0
5.8
7.8
2.0
3.1
4.1
5.1
6.0
8.0
2.0
3.2
4.2
5.3
6.2
8.3
2.2
3.4
4.5
5.6
6.5
8.8
CAP
kW
37.4
55.9
75.6
95.3
111.8
148.3
38.5
57.8
77.8
98.0
114.9
153.0
39.7
59.8
79.9
100.9
118.0
157.9
40.7
61.9
82.4
103.7
121.0
162.8
43.0
66.1
87.4
109.5
127.5
172.9
35
COMP
kW
12.8
20.1
27.0
33.3
39.6
53.1
12.9
20.3
27.3
33.7
40.4
53.9
13.0
20.4
27.5
34.4
41.7
54.8
13.2
20.6
27.8
34.7
42.3
55.6
13.5
20.9
28.3
35.6
43.7
57.4
FLOW
I/s
1.8
2.7
3.6
4.5
5.3
7.1
1.8
2.8
3.7
4.7
5.5
7.3
1.9
2.9
3.8
4.8
5.6
7.5
1.9
3.0
3.9
5.0
5.8
7.8
2.1
3.2
4.2
5.2
6.1
8.3
CAP
kW
35.1
51.2
70.0
88.2
104.2
137.6
36.1
53.1
72.1
90.8
107.0
141.9
37.1
55.0
74.3
93.4
109.8
146.5
38.2
56.9
76.5
96.1
112.6
151.1
40.3
60.9
81.0
101.4
118.4
160.6
40
COMP
kW
14.0
22.2
30.5
36.6
42.7
57.8
14.2
22.4
30.7
37.0
43.6
58.6
14.3
22.5
30.9
37.5
44.5
59.5
14.5
22.7
31.2
38.0
45.5
60.4
14.8
23.0
31.7
38.9
47.4
62.2
FLOW
I/s
1.7
2.4
3.3
4.2
5.0
6.6
1.7
2.5
3.4
4.3
5.1
6.8
1.8
2.6
3.5
4.5
5.2
7.0
1.8
2.7
3.7
4.6
5.4
7.2
1.9
2.9
3.9
4.8
5.7
7.7
CAP
kW
32.5
46.3
64.0
80.4
95.4
125.9
33.5
48.0
66.0
82.8
98.4
129.9
34.4
49.7
67.8
85.2
101.0
134.1
35.4
51.5
69.8
87.6
103.6
138.4
37.3
55.3
74.0
92.4
108.7
147.2
45
COMP
kW
15.6
24.7
33.4
40.0
46.7
63.1
15.7
24.8
33.6
40.4
47.0
63.9
15.9
25.0
33.8
40.9
47.8
64.7
16.1
25.1
34.2
41.4
48.8
65.5
16.4
25.5
34.6
42.4
50.7
67.4
FLOW
I/s
1.6
2.2
3.1
3.8
4.6
6.0
1.6
2.3
3.1
4.0
4.7
6.2
1.6
2.4
3.2
4.1
4.8
6.4
1.7
2.5
3.3
4.2
4.9
6.6
1.8
2.6
3.5
4.4
5.2
7.0
Model
039S
060S
080S
100S
120S
160S
039S
060S
080S
100S
120S
160S
039S
060S
080S
100S
120S
160S
039S
060S
080S
100S
120S
160S
039S
060S
080S
100S
120S
160S
LWT
℃
5
5
5
5
5
5
6
6
6
6
6
6
7
7
7
7
7
7
8
8
8
8
8
8
10
10
10
10
10
10
9
Operating Range, 30RB039S~160S
0 5 10 15 20 25
Evaporator leaving water temperature,℃
Operating range
Out
side
air
tem
pera
ture
,o C
Full load
Minimum load
Cooling mode
Evaporator
Entering water temperature at start-up
Leaving water temperature during operation
Entering/leaving water temperature difference
Condenser
Outdoor air temperature*
7.5℃
5℃
K3
-10℃
Minimum Maximum
Minimum Maximum
30℃
20℃
K10
48℃
* Maximum outside temperature: For transport and storage of the 30RB/RQ units the minimum and maximum allowable temperatures are -20℃ and +48℃. It is recommended that these temperatures are used for transport by container.
50
45
40
35
30
25
20
15
10
5
0
-5
-10
-15
10
Operating Range, 30RQ039S~160S
Operating range - cooling mode Operating range - heating mode
Cooling mode
Water heat exchanger (Evaporator)
Entering water temperature at start-up
Leaving water temperature during operation
Entering/leaving water temperature difference
Air heat exchanger (Condenser)
Outdoor air temperature*
Minimum
7.5℃
5℃
K3
Maximum
Minimum Maximum
30℃
℃20
K10
48℃
Heating mode
Water heat exchanger (Condenser)
Entering water temperature at start-up
Leaving water temperature during operation
Entering/leaving water temperature difference
Air heat exchanger (Evaporator)
Outdoor air temperature
8℃
25℃
K3
-10℃*
Minimum Maximum
Minimum Maximum
30℃
55℃
K10
40℃
-20
-10
0
10
20
30
40
50
0 5 10 15 20 25
Full load
Minimum load
Out
side
air
tem
pera
ture
, ℃
Evaporator leaving water temperature, ℃
* Maximum outside temperature: For transport and storage of the 30RB/RQ units the minimum and maximum allowable temperatures are -20℃ and +48℃. It is recommended that these temperatures are used for transport by container.
* Min -15℃ during part load operation
20
25
30
35
40
45
50
55
60
-20 -10 0 10 20 30 40 50
Leav
ing
wat
er te
mpe
ratu
re, ℃
Outdside air temperature, ℃
Full load
Minimum load
-10℃
11
Options & accessories
Options
Blygold PoluAl
Gold Fins
Super low noise
Soft starter
Winter operation
Fixed speed dual
pump hydronic module
Unit without hydronic
module
J-Bus gateway
BacNet gateway
LonTalk gateway
No.
002B
003A
015LS
025
028
116C
116D
148B
148C
148D
Description
Coils with factory-applied
Blygold Polual treatment
Fins made of pre-treated aluminium
(polyurethane and epoxy)
Acoustic compressor enclosure and
low speed fans
Electronic compressor starter
Fan speed control
by frequency inverter
Provide fixed speed dual pumps of
200KPa external pressure
Flexible for customer to purchase
and install the water components
by themselves
Two-directional communication board
with J-Bus protocol
Two-directional communication board
with BacNet protocol
Two-directional communication board
with LonTalk protocol
Advantages
Improved corrosion resistance,
recommended for heavy marine
and industrial environments
Improved corrosion resistance,
recommended for light marine
environments
Super low operating noise
Reduced compressor
start-up current
Stable operation between
-10 ℃and -20 ℃ outdoor air
temperature
Easy and fast installation,
operating safety
-
East connection by
communication bus to a
building management system
East connection by
communication bus to a
building management system
East connection by
communication bus to a
building management system
Use
30RB039-160S
30RB039-160S
30RB039-160S
30RQ039-160S
30RB039S-080S
30RQ039S-078S
30RB039S-080S
30RB039-160S
30RQ039-160S
30RB039-160S
30RQ039-160S
30RB039-160S
30RQ039-160S
30RB039-160S
30RQ039-160S
30RB039-160S
30RQ039-160S
12
Dimensions/Clearances
30RB039S~080S/30RQ039S-078S
2
1
1
2
1061
1330
2050
1000
1000 1000
1000
Control box
Water outlet
Water inlet
Required clearances for air entry
Recommended space for maintenance
Air outlet - do not obstruct
Power supply inlet
2
1
Legend:All dimensions are given in mm
13
Dimensions/Clearances
30RB100S~160S/30RQ100S-160S
2 2
1
1
1
1
2050
1000
1000
1330
2258
1000
1000
Control box
Water outlet
Water inlet
Required clearances for air entry
Recommended space for maintenance
Air outlet - do not obstruct
Power supply inlet
2
1
Legend:All dimensions are given in mm
14
Multiple Chiller Installation
Multiple Chiller Installation
Note: If the height of wall exceeds 2m, please contact local Carrier Sales & Service Corporation.
WallWall
Unit's footprint
Square hole 100x100
Section F - F
Note: 4 foot screws M1x220
Square hole 100x100
250
250
250
50
300
150
P3 P4
C
A
F
P2P1
F
B D
Section F - F
Note: 4 foot screws M16x220
30RB039S
30RB060S
30RB080S
30RB100S
30RB120S
30RB160S
488
545
562
877
912
1114
Dimensions (mm) Weight distribution (kg)Models Operating
weight
30RQ039S
30RQ060S
30RQ078S
30RQ100S
30RQ120S
30RQ160S
159
176
181
239
246
312
P1
174
188
190
255
268
313
147
154
159
303
310
357
P2
161
164
167
323
338
358
87
100
104
187
199
237
P3
96
107
109
199
217
238
94
115
118
148
157
207
P4
103
123
124
158
171
208
535
582
590
935
995
1117
1061
1061
1061
2258
2258
2258
A
1061
1061
1061
2258
2258
2258
2050
2050
2050
2050
2050
2050
B
2050
2050
2050
2050
2050
2050
1017
1017
1017
2214
2214
2214
C
1017
1017
1017
2214
2214
2214
2002
2002
2002
2002
2002
2002
D
2002
2002
2002
2002
2002
2002
10001000
1000
1000
2000
1000
2000
2000
2000
15
Hydronic Connections
Legend:Components of the unit and hydronic module
2 Expansion tank1 Victaulic screen filter
3 Safety valve4 Water pump5 Purge valve and pressure tap6 Pressure gauge7 System air vent8 Flow switch9 Flow control valve10 Brazed plate heat exchanger11 Evaporator frost protection heater12 Temperature sensor
Installation components13 Air vent14 Flexible connection15 Check valve16 Shut-off valve17 Pressure gauge18 Frost protection bypass valve (must have when shut-off valves [16] are closed during winter)19 Charge valve20 Evaporator water inlet21 Evaporator water outlet22 Chiller water inlet23 Chiller water outlet24 Customer water connections (provided with chiller)25 Temperature probe well26 System drain valve
2985
67
20
21 12 3
4 1 26
22
23
24
1
2
16
16
19
25
25
9
18
13
14
14
15
17
17
10
117 6
5
5
12
12
3
8
4
16
Unit Internal Water Pressure Drop
Available Static System Pressure
Pre
ssur
e dr
op, k
Pa
20
0 1 2 3 4 5 6 7 8 9 10 11 12
40
60
80
100
120
140
160
180
30RB039S/30RQ039S 30RB060S/30RQ060S 30RB080S/30RQ078S
30RB100S/30RQ100S 30RB120S/30RQ120S 30RB160S/30RQ160S
Ava
ilabl
e st
atic
pre
ssur
e, k
Pa
150
170
190
210
230
250
270
1
1
0 3
3
2
2
54
4
1 32
4 5 6
76 8 9 10 11 12
431 2
30RB039S~060S/30RQ039S~060S
Water flow rate,l/s
Water flow rate,l/s
30RB080S/30RQ078S 30RB100S~120S/30RQ100S~120S 30RB160S/30RQ160S
6543
2
1
17
Minimum Water Loop Volume
Maximum Water Loop Volume
For better control of leaving water temperature, the water loop minimum capacity is given by the formula: Capacity = CAP (kW) × N Liters
CAP: Unit’s nominal cooling capacity
It is often necessary to add a buffer water tank to the circuit in order to achieve the required volume. The tank must itself be internally baffled in order to ensure proper mixing of the liquid (water or brine). Refer to the examples below.
The expansion tank of the unit with hydronic module limits the maximum water volume, refer to below sheet:
Water-side static pressure
Pure water
10%EG
20%EG
30%EG
40%EG
kPa
L
L
L
L
L
100
600
450
330
270
225
200
400
300
220
180
150
300
200
150
110
90
75
100
1680
1260
930
750
630
200
1120
840
620
500
420
300
560
420
310
250
210
EG: Ethylene glycol
30RB039S~080S/30RQ039S~078S 30RB100S~160S/30RQ100S~160S
Application
Comfort air conditioning 30RB039S~160S/30RQ039S~160S
Process cooling 30RB039S~160S/30RQ039S~160S
3.5
N
Should be greater than 3.5 for better water temperature control
Bad Good Bad Good
18
Field Control Wiring
Boi
ler c
ontro
l
Circ
uit A
ala
rm
Cus
tom
er c
ontro
l sys
tem
Dem
and
limit
/ dua
l set
poi
nts
Rem
ote
cool
ing
/ hea
ting
switc
h
Rem
ote
On/
Off
Cus
tom
er c
ontro
l sys
tem
Dem
and
limit
#1
Rem
ote
cool
ing
/ hea
ting
switc
h
Rem
ote
On/
Off
Circ
uit A
ala
rm
Boi
ler c
ontro
l
2 se
t poi
nts
Com
plem
enta
ry s
et p
oint
Dem
and
limit
#2
Circ
uit B
ala
rm
30RB039S~080S/30RQ039S~078S
30RB100S~160S/30RQ100S~160S
1.5mm2MAX24VAC 20mA
2.5mm2 MAX24VAC 48VDC MAX
20V M N
1.5mm2 MAX24VAC 20mA
1.5mm2 MAX24VAC 20mA
2.5mm2MAX24VAC 48VDC MAX
20V M N
38
31B 30B 76 75 68 67 66 65 38 37 31A 30A 35 34 74 73 64 63 33 32
37 31 30 35 34 74 73 64 63 33 32
2.5mm2MAX24VAC-48VDC MAX
20V MIN