30GN040-110 FLOTRONIC™ II AIR-COOLED CHILLERS — PERFORMANCE DATA — CERTIFIED DIMENSION PRINT — FIELD WIRING DIAGRAM 30GN-19SB R 1998 Carrier Corporation • Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed in U.S.A. 3-98 Catalog No. 513-451 30GN-14SB, 30GN-15SB

Transcript of 30GN040-110 FLOTRONIC™ II AIR-COOLED...

30GN040-110FLOTRONIC™ II

AIR-COOLED CHILLERS— PERFORMANCE DATA

— CERTIFIED DIMENSION PRINT

— FIELD WIRING DIAGRAM

30GN-19SB

R 1998 Carrier Corporation • Syracuse, New York 13221

Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed in U.S.A. 3-98 Catalog No. 513-45130GN-14SB, 30GN-15SB

Date: Supersedes: 30GN040-110 FLOTRONIC™ IIAIR-COOLED CHILLERS 30GN Rev.:

-19SB

JOB NAME: LOCATION:

BUYER: BUYER P.O. # CARRIER #

UNIT NUMBER: MODEL NUMBER:

PERFORMANCE DATA CERTIFIED BY: DATE:

DESCRIPTIONThese air-cooled package chillers are factory piped, wired and charged with Refrigerant 22. Rugged, weatherproof construc-tion and compact design make them ideal for rooftop or ground level installation. Upward discharge airflow minimizesdirectional sound and dissipates heat away from surrounding areas.

FEATURESStandard one-year warranty.

Multiple reciprocating serviceable-hermetic compressors mounted on spring iso-lated rails. Automatically reversible oil pump, thermal overload protection, suc-tion and discharge service valves.

Electronic ground current sensing device for each circuit.

Calibrated, ambient compensated magnetic-trip circuit breakers with manualreset provide single-phase and phase-reversal protection.

Insert-type 180-watt crankcase heaters.

High- and low-pressure safety switches.

Dual refrigerant circuits. Each refrigerant circuit contains: Hot gas muffler foreach compressor, excessive pressure relief device, liquid line shut-off valve,replaceable-core filter drier, moisture indicating sight glass, loss of oil pressureprotection.

Electronic expansion valve in each refrigeration circuit.

Automatic lead-lag feature automatically alternates the lead circuits to ensureeven compressor cycles and run time.

Single point main power connection.

Compressor timed pumpdown cycle at start-up and stopping of each refrig-eration circuit cooling cycle.

Unit capable of starting with up to 95° F water entering the cooler, with 125° Foutdoor air.

Units are capable of starting and operating down to 0° F outside-air tempera-tures with wind baffles installed. Below 0° F outside-air temperature, the unitmust be modified for low-ambient operation. Below 32° F, unit must be equippedwith wind baffles.

Control capacity based on leaving water temperature, compensated byreturn water temperature.

Low water flow detection provided by internal control devices.

Cooler flow may be either constant or variable.

Provisions can be made for reset by either outdoor, space, or return-water tem-perature. (Return standard.)

8-Digit alphanumeric diagnostic display and set point panel for set points, serv-ice diagnostics and operational quick tests. Displays chiller temperatures, pres-sures (including oil), set points, and accumulated starts and run time for eachcircuit.

Integral shell-and-tube cooler with dual refrigerant circuits, expanded poly-vinyl chloride insulation (and electric heater cable for freeze protectionoptional).

Non-ferrous condenser coils with mechanically bonded plate fins and integralsubcooling circuit.

Direct-drive condenser fans and motors are supported by a formed-wire mountto reduce vibration.

Fan motors are three-phase with permanently lubricated ball bearings andinherently protected.

Multiple fans are used for head pressure control during intermediate season.

Unit can be equipped (accessory) with a two-point demand limit control (each0-100%) activated remotely by an electric signal.

The unit cabinet consists of galvanized steel casing, zinc phosphatized, withan electrostatically applied baked enamel finish, capable of withstanding a500-hour salt spray test.

Hinged control box access panels.

Alarm circuit wiring standard, field-supplied bell required.

7-Day time schedule.

PERFORMANCE DATAUNIT

Capacity (tons)

Compressor Input Power kW

Unit Power Input kW

Minimum Outdoor Operating Temperature °F

Capacity Control Steps Minimum Capacity %

Refrigerant

Condenser Entering Air Temperature °F

Saturated Discharge Temperature °F

COOLER

EnteringWater Temperature °F

LeavingWater Temperature °F

Chilled Flow Rate Gpm

Chilled Water Pressure Drop ft wg

Fouling Factor

Fluid

ELECTRICAL DATA

Power Supply to Unit Volts Ph Hz

Power Supply to Control Circuit Volts Ph Hz

Maximum Instantaneous Current Flow Amps

Minimum Circuit 1

Maximum Fuse Amps

Control Circuit Fuse Amps

FACTORY-INSTALLED OPTIONS

M Motormastert III Control M High Static FansM Copper-Copper Condenser Coils M Non-Fused DisconnectM Brine — 15° F to 40° F LWT M Precoated Aluminum FinsM Cooler Heater M Postcoated Copper FinsM Part Wind Start M Postcoated Aluminum Fins

ACCESSORIES

M

M

M

M

M

M

M

M

2

CERTIFIED DIMENSION PRINT

3

CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

CERTIFIED DIMENSION PRINT

4

CERTIFIED DIMENSION PRINT

5

CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

CERTIFIED DIMENSION PRINT

6

CERTIFIED DIMENSION PRINT

7

CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

FIELD WIRING DIAGRAM

8

FIELD WIRING DIAGRAM

9

CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -