30.22.7.012.0010-Finder-datasheet-548493
-
Upload
tony-rodriguez -
Category
Documents
-
view
65 -
download
0
Transcript of 30.22.7.012.0010-Finder-datasheet-548493
• Low coil power• Au clad contacts• PCB mount
11.4
20.3
7.62 5.08 7.62
0.4
10.1
4
5.08 1.10.7
5.087.62
7.62
0.8
A1 A2
12
11 21
14 22 241211A1
A2
14
2221 24
2 CO (DPDT)
2/3
125/250
125
25
—
2/0.3/—
10 (0.1/1)
AgNi + Au
—
5 - 6 - 9 - 12 - 24 - 48
—/0.2
—
See table page 2
—/0.35 UN
—/0.05 UN
—/10 · 106
100 · 103
6/2
1.5
750
–40…+85
RT III
30.22
1
30 Series - Subminiature DIL relays 2 A
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (UN) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
Copper side view
FeaturesPrinted circuit mount 2 Asignal relay
• 2 Pole changeover contactsLow level switching capability
• Subminiature - industry standard DIL package• Sensitive DC coil - 200 mW • Wash tight: RT III• Cadmium Free contact material
Technical data
(A)1,50,50 21
106
105
107
2.5
1.0
0.5
1.5
UUN
2.0
60-20 0 4020 80
2
1
(°C)
InsulationInsulation according to EN 61810-1 insulation rated voltage V 125 250
rated impulse withstand voltage kV 1.2 1.2pollution degree 2 1overvoltage category I I
Insulation between coil and contacts (1.2/50 µs) kV 1.5 Dielectric strength between open contacts V AC 750Dielectric strength between adjacent contacts V AC 1,500Other dataBounce time: NO/NC ms 1/3Vibration resistance (5…55)Hz, max. ± 1 mm: NO/NC g 15/15Shock resistance g 16Power lost to the environment without contact current W 0.2
with rated current W 0.4Recommended distance between relays mounted on PCB mm ≥ 5
Nominal Coil Operating range Resistance Rated coilvoltage code consumption
UN Umin Umax R I at UN
V V V Ω mA5 7.005 3.7 7.5 125 406 7.006 4.5 9 180 339 7.009 6.7 13.5 405 2212 7.012 8.4 18 720 1624 7.024 16.8 36 2,880 8.348 7.048 36 72 11,520 4.1
DC coil data - 0.2 W sensitiveCoil specifications
1 - Max. permitted coil voltage.2 - Min. pick-up voltage with coil at ambient temperature.
Example: 30 series PCB relay, 2 CO (DPDT) - 2 A contacts, 12 V sensitive DC coil.
A: Contact material0 = Standard
AgNi + Au (5 µm)
B: Contact circuit0 = CO (DPDT)
Coil voltageSee coil specifications
Series
Type2 = PCB mount
No. of poles2 = 2 pole, 2 A
Coil version7 = Sensitive DC
2 2 07
D: Special versions0 = Wash tight (RT III)
C: Options1 = None
Ordering information
A B C D
. . . .0 1 23 0
30 Series - Subminiature DIL relays 2 A
2
0 1 0
F 30 - Electrical life (AC1) v contact current (125 V)
Cyc
les
Contact specification
R 30 - DC coil operating range v ambient temperature
Note:The rated current of 2 A corresponds to the limiting continuous current.