30186-04 Kompakt-WMZ TKS-WM … Lithium battery safety Certain components of the heat meter can be...
Transcript of 30186-04 Kompakt-WMZ TKS-WM … Lithium battery safety Certain components of the heat meter can be...
1
Installation instructionsFor competent personnel only
Deltamess TKS-WM compact heat meterHeat meters
IMPORTANT!READ CAREFULLY BEFORE USE.
KEEP FOR THE ENTIRE PRODUCT LIFE.
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 1 03.12.2015 15:14:52
2
Scope of delivery
Heat meter (calculator with measuring capsule incl. installed temperature sensor)Blister pot (measuring capsule protective cap)
Installation instructionsOperating manual with CE-Declaration of conformity with disposal instructionsUse information for existing pockets (for Germany only)Accessory kit with two security sealsTemperature sensor for ball valve / tee (O-ring red) preassembled- Consisting of: 1 x TF bolt (0352), 1 x extension ring (1520)- 1 x O-ring black (1109) 1 x O-ring green (0787), 1 O-ring red V-pipe (0759)
Please keep the documentation for the entire life.
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 2 03.12.2015 15:20:52
Temperature sensor for body TKS (O-ring blue) preassembled- Consisting of: 1 x TF bolt (0352), 1 x extension ring (1520) ,- 1 x O-ring black (1109), 1 x O-ring green (0787), 1 O-ring blue R-pipe (0760)
3
Contents
Scope of delivery .....................................................................................................2Contents ...................................................................................................................3Safety and warranty ................................................................................................5
Important note ................................................................................................................ 5Lithium battery safety .............................................................................................6
Safety instructions for lithium batteries ............................................................................. 6Technical data ..........................................................................................................7
Standards and directives................................................................................................... 7Calculator .......................................................................................................................... 7Connection sizes and dimensions..................................................................................... 8Temperature sensor .......................................................................................................... 8Calculator - volume measuring part connection cable ...................................................... 8
Dimensioned drawings ...........................................................................................9TKS-WM interface DM1 .................................................................................................... 9TKS-WM temperature sensor for housing......................................................................... 9Overall TKS-WM lengths ................................................................................................. 10TKS-WM housing sensor installation .............................................................................. 12
Symbols and warnings .........................................................................................14Installation positions .............................................................................................15Installation variants - without pocket ..................................................................16
Housing without shut-off valves ...................................................................................... 16Housing with shut-off valves ........................................................................................... 16
Installation variants - with pocket ........................................................................17Housing without shut-off valves ...................................................................................... 17Identifying the EAT .......................................................................................................... 17
Prepare for installation - without pocket .............................................................18- for new installation ........................................................................................................ 18- for instrument replacement ........................................................................................... 18
Prepare for installation - with pocket ..................................................................19- for new installation ........................................................................................................ 19- for instrument replacement ........................................................................................... 19
Installing the heat meter (heat meter replacement part available) ...................20Preparing for installation ................................................................................................. 20Installing the housing ...................................................................................................... 20Insert the measuring capsule, note the flow direction ..................................................... 21Fixing the measuring capsule ......................................................................................... 22
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 3 03.12.2015 15:22:52
4
Contents
Installing the temperature sensor - without pocket (ball valve)........................23Temperature sensor - diameter 5.2 mm .......................................................................... 23
Installing the temperature sensor - with pocket .................................................24Wall-mounted installation with removable calculator ........................................25Check the installation ...........................................................................................26
Open the shut-offs ........................................................................................................... 26Check for leaks and check flow direction ........................................................................ 26
Sealing the instrument ..........................................................................................27Sealing the flow sensor ................................................................................................... 27Sealing the temperature sensor in the ball valve ............................................................ 27Sealing the temperature sensor in the pocket................................................................. 28
Note the meter readings .......................................................................................28Instrument elements .............................................................................................29
Controls and interfaces ................................................................................................... 29Status displays ................................................................................................................ 29
Display ....................................................................................................................30Special operating states .................................................................................................. 30Error messages ............................................................................................................... 30
Key assignments ...................................................................................................31Key assignment in default mode ..................................................................................... 31Key assignment in programming mode........................................................................... 31
Putting into use .....................................................................................................32Activate programming mode ........................................................................................... 32Example: Programming the reference date .................................................................... 32Example: Activating / deactivating levels ........................................................................ 33Example: Switch the check number display on / off (postcard readout) ......................... 33Example: Change the dimensional unit (kWh <−> MWh or MJ <−> GJ) ....................... 34
Installation suggestions .......................................................................................35Checklist.................................................................................................................36
Before the installation...................................................................................................... 36Following installation ....................................................................................................... 37After putting into use ....................................................................................................... 37
Notes on heat meter add-on modules ................................................................38Use of combined heat/cooling meters with add-on module ..................................... 38WFZ16x.Ox - add-on radio module ................................................................................. 38R99/0005-02 - add-on M-Bus module ............................................................................. 39
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 4 03.12.2015 15:29:52
Temperature sensor mouting ..........................................................................................23
5
This product must be installed properly and in accordance with the specified installation guidelines and may therefore only be installed by trained, qualified competent personnel.
Intended useHeat meters are used for central recording of heating energy consumption. Heat meters are intended for this use only.
Improper useAny use other than the use described above or any changes made to the instru-ment constitutes improper use. Enquiries concerning other uses and modifica-tions must be made in writing beforehand and must be especially approved.
Warranty and guaranteeWarranty and guarantee claims can only be made if the parts have been used as intended and if the technical requirements and relevant technical regulations have been observed.
Safety instructionsImproper handling or excessive tightening of threaded connections can cause leaks. Observe the maximum torque stated in the manual. The dimensions and thermal loads of seals must be suitable for their intended use. You must there-fore only use the seals supplied with the instrument.
Radio systemThe radio system rcu4 or the radio modules are not compatible with this heat meters.
The installed meter is a pressurized component.Risk of scalding due to hot water.
Safety and warranty
Important notes
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 5 10.02.2015 09:44:52
6
Lithium battery safety
Certain components of the heat meter can be equipped with a lithium battery.This type of battery is classified as dangerous goods.
ALWAYS COMPLY WITH THE RESPECTIVE VALID TRANSPORT REGULA-TIONS! Test certificates for the batteries used are available on request.Handling lithium batteries:• store protected from moisture• do not heat above 100 °C or throw in fire• do not short-circuit• do not open or damage• do not charge• keep out of the reach of children
Observe the following instructions in emergencies:In the event of leaks:- Cover with sodium carbonate or soda crystals.- Condense gases and fumes by spraying water.- Ensure adequate ventilation.- Avoid all direct contact.In the event of injuries:- If the internal constituents of the dry element come into contact with the
eyes, rinse immediately with water for 15 minutes.- In case of contact with the skin, wash with plenty of water and remove con-
taminated clothing.- After inhaling, move away from the place in which the accident occurred.- Always consult a doctor!In the event of fire:- Use a Lith-X or class D fire extinguisher!- NEVER EXTINGUISH WITH WATER!- Do not use CO2 or halogen fire extinguishers, fire extinguishers with dry
substances or foam fire extinguishers!- After inhaling, move away from the place in which the accident occurred and
ventilate.- Always consult a doctor!
Safety instructions for lithium batteries
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 6 10.02.2015 09:44:53
7
Technical data
CE conformity refer to Declaration of Conformity (enclosed)
Electromagnetic compatibilityInterference resistance EN 61000-6-2Emitted interference EN 61000-6-3
Degree of protectionIP protection rating IP65
Heat metersEuropean Measuring Instruments Directive (MID)EC type examination certificate
2004/22/EGDE-12-MI004-PTB009
Heat meters EN1434Heating medium quality to VDI Guidelines 2035
to AGFW-Norm 510
Influence quantitiesElectromagnetic class E1Mechanical class M1Environmental class AMeasurement accuracy class 3
Standards and directives
Temperature rangeas heat meter 20 °C ... 105 °CAllowable temperature differenceTemperature difference when me-tering begins
3 K - 70 KHeat: 0.2 K
Ambient temperature 5 °C ... 55 °C
Power supplyLithium battery Nominal voltage 3.0 VLife > 6 (opt. 10) years + 6 months reserveMeasuring cycle 36 seconds (opt. 6 seconds)
Display levelsDefault min. 2, up to max. 10
(depending on the version and options included)Display 8-digit LCD + pictogramsEnergy display kWh (opt. MWh, MJ, GJ)
Calculator
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 7 10.02.2015 09:44:53
8
Technical data
Connection sizes and dimensions 1.5 m3/hInstallation location ReturnInstallation length of the EAT 110 mm 130 mmPipe connection 3/4 inch OD 1 inch ODWeight (capsule + calculator) 380 g 380 gInstallation position horiz./vert. horiz./vert.Meter thread at the EAT M60x2 M60x2Nominal flow qp 1.5 m3/h 1.5 m3/hMinimum flow qi horizontal 30 l/h 30 l/hvertical 60 l/h 60 l/hRatio qp/qi horizontal 50:1 50:1vertical 25:1 25:1Ratio qs / qp 2:1 2:1Start-up < 6.0 l /h < 6.0 l /hMax. allowable operating pressure 1.6 MPa (16 bar) 1.6 MPa (16 bar)min. system pressure to prevent cavitation 0.1 MPa (1 bar) 0.1 MPa (1 bar)Pressure loss by qp ~ 220 mbar ~ 220 mbarTemperature range 20 °C … 90 °C 20 °C … 90 °C
Connection sizes and dimensions
Sensor diameter and cable lengthsFlow temperature sensor (red) 5.2 mm 1.5 m (opt. 3 m)Return temperature sensor (blue) 5.2 mm 0.8 m
Cable length (wall-mounted calculator) 30 cm
Temperature sensor
Calculator - volume measuring part connection cable
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 8 10.02.2015 09:44:53
9
Dimensioned drawings
TKS-WM interface DM1
TKS-WM temperature sensor for housing
AA
1.1
1.2
1.3
B
A-A
Temperaturfühler (TF) Ø5,2mm direkt tauchend
TF-Habschalen verschraubung
Tauchfühler Ø5,2
Verlängerungsring (2289)
O-Ring (0787)
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 9 03.12.2015 15:31:53
2. TF bolt (20352)3. O-ring (21109)4. Extension ring (21520)5. Temperature sensor Ø 5.2 mm6. O-ring green (20787)
5
3
2
1
4
6Torque 5Nm
1. O-ring for sensor identification V-pipe=red (20759) / R-pipe=blue (20760)
10
Dimensioned drawings
Overall TKS-WM lengthsOverall length 110 mm
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 10 13.12.2015 15:44:53
110
101,50 G
3/4
110
101,50
G 3
/4
78
63
93
74
11
Overall TKS-WM lengths
Dimensioned drawings
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 11 10.02.2015 09:44:53
78
93
74
101,5
130
G1
Overall length 130 mm
12
Dimensioned drawings
TKS-WM body sensor installationOverall length 110 mm / 130 mm
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 12 03.12.2015 16:14:53
4
3
2
1
5
6
1. O-ring for sensor identification V-pipe=red (20759) / R-pipe=blue (20760)2. TF-bolt (20352)3. O-ring black (21109)4. Extension ring (21520)5. O-ring green (20787)6. Temperature sensor Ø 5,2 mm
13
Dimensioned drawings
TKS-WM body sensor installationOverall length 130 mm with 2 cut-offs
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 13 03.12.2015 20:04:53
1. O-ring for sensor identification V-pipe=red (20759) / R-pipe=blue (20760)2. TF-bolt (20352)3. O-ring black (21109)4. Extension ring (21520)5. O-ring green (20787)6. Temperature sensor Ø 5,2 mm
A
4
3
21
5
6
TKS Gehäuse Baulänge 130 mm
14
Symbols and warnings
This type of battery is classified as dangerous goodsCertain components of the heat meter can be equipped with a lithium battery.
Risk of scalding due to hot waterAn installed meter is a pressurized component!To be installed by trained competent personnel only.
The heat meter may only be installed in single tube connectors (EAS) and only without use of adapter rings and adapters.
The sensor cables (e.g. temperature sensor cable) must be laid at a distance of at least 50 mm from sources of electromagnetic interference (switches, electric motors, fluorescent lamps).
Installation variant without pocket This variant is recommended!
Installation variant with pocketPlease observe national and country-specific regulations concerning the use of pockets!
Flow directionEnsure correct flow or return installation and the installation position (flow direction) of the flow sensor!
Important notesPlease note and follow the instructions and regulations!
Additional informationUseful and additional information on the installation.
Refer to and follow the instruction manual, operating conditions and instal-lation requirements to EN 1434-6!
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 14 10.02.2015 09:44:54
15
Installation positions
Horizontal installation
Tilted vertical installation
Vertical installation
NO overhead installation
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 15 10.02.2015 09:44:54
16
Body without shut-off valves
Body with shut-off valves
Installation variants - without pocket
1. Return sensor without pocket integrated in the flos sensor body 2. Flow sensor without pocket
1
2
2
1
1. Return sensor without pocket integrated in the flos sensor body 2. Flow sensor without pocket
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 16 03.12.2015 20:28:54
17
Body without shut-off valves
Installation variants - with pocket
regulations concerning the use of pockets (thermowells)!
sensor body2. Flow sensor with pocket
Identifying the EAT• Check whether the body is marked " DM1".
If the body has this marking, the measuring capsule can be used without any further tests.
• Check whether there is a delta symbol (triangle) on the body. If in doubt, check whether the body matches the dimen-sions given on page 9 of these instructions.
• If the dimensions determined do not correspond
measuring capsule cannot be installed in the existing body.
Marking
See page 9 for dimensions
If the body does not have any markings
2
1
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 17 03.12.2015 20:44:54
18
Prepare for installation - without pocket
- for new installation
- for instrument replacement
1. Ball valve available with connection for flow sensor without pocket
1. Ball valve available with connection for flow sensor without pocket.
• Flush the system• Close the ball valves
• Close the ball valves• Remove the seals
1
1
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 18 10.02.2015 09:44:54
19
Prepare for installation - with pocket
- for new installation
- for instrument replacement
• Flush the system• Close the ball valves• Remove protective cap from
the pocket
• Close the ball valves• Remove the seals• Remove the temperature sensor
from the pocket
Observe national and country-specific regulations con-cerning the use of pockets (thermowells)!
Observe national andcountry-specific regulations
concerning the useof pockets (thermowells)!
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 19 10.02.2015 09:44:54
20
Installing the heat meter (heat meter replacement part available)
Preparing for installation
Installing the body
1
1
2
2
3. Install the body, 4. Use the enclosed seals5. Tighten the union nuts
3 4
5
6
1. Close taps/valves (shut off water)2. Undo union nuts and remove replacement part
4
5
66
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_031215_EN.indd 20 03.12.2015 20:48:54
21
Installing the heat meter
Preparing for installation (dismantling the old instrument)
• Undo existing meters with a hook wrench and remove
• Remove all seals• Remove temperature sensor• Remove all O-rings
Insert the measuring capsule, note the flow direction• Remove the blister pot (protective
cap) from the measuring capsule.
• If necessary, regrease the seals on the measuring capsule which were greased in the factory (braces seal and red O-ring on head ring).
DO NOT USE FERMIT!
• Insert the measuring capsule as indicted by the flow direction arrow, twist the capsule onto the gear ring by hand.
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 21 10.02.2015 09:44:55
22
Fixing the measuring capsule• Use the hook wrench to tightly screw
the head ring of the measuring capsule until it stops.
• Align the calculator in the readout position.
• Fit the sealing ring above the head ring, seal and insert push-fit seal.
• Install and seal the temperature sensor using the enclosure provided for this purpose.
1. Position the sealing ring and push together
2. Insert the push-fit seal completely, with the "nose" at the seal tip pointing towards the housing.
1
2
Inserting the measuring capsule
• Push in the new measuring capsule and turn by hand
• Wide nose in the wide groove (flow direction pre-determined)
Installing the heat meter
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 22 10.02.2015 09:44:55
23
Installing the temperature sensor - without pocket (ball valve)
The temperature sensors for the flow- and reture pipe are peassembled with the necessary mounting hardware.
Temperature sensor - diameter 5.2 mm (preassembled)
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_041215_EN.indd 23 04.12.2015 09:43:00
Temperature sensor must not touch the bottom!
1. Temperature sensor identificionBLUE (Return): for body TKSRED (Flow): for ball valve / tee
2. Sensor-bolt (brass-screwing)
3. O-ring black (auxiliary member for mounting)4. Grooves for the immersion depth of the sensor(3 x)5. Extension ring (no. 21520)6. O-ring green (sealing element)
Temperature sensor mounting
1.) Position displayed all assembly parts as in P1 IMPORTANT: The black O-ring 3 should line up in the middle groove
(*)
2.) Slide the extension ring as in mapped to the black O-ring. 5 P2
3.) Slide the sensor bolt as in displayed on the black O-ring to the collar of the extension ring .
2 P35
4.) Slide the green O-ring under the extension ring.6 P45.) Screw the assembled temperature sensor in the ball valve, respectively into the tee or in the housing. P5
OK
OK
FALSE
P1 P2 P3 P4 P5
immersion depth > 50 %, < 99 %
(*) The black O-ring must not be placed in the first groove.If the temperature sensor too deeply immersed in themeasuring point, the black O-ring moved into the thirdgroove. Temperature sensor must not touch the ground!
1 2
3 6
54
24
If the temperature sensor is installed in third-party pockets the type offixing can differ from the above description. If necessary, use the fixingmaterial of the removed instrument.
In EU states (except Germany) pockets are also approved for new installations, if they conform to the MID.In Germany, pockets are not approved for new installations! For replace-ment installations the enclosed user information for existing pockets must be observed!
Use a tightening torque of approx. 3 Nm (hand-tight) to tighten the temperature sensor with union fitting in the pocket.
Installing the temperature sensor - with pocket
-ing the use of pockets (thermowells)!
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_041215_EN.indd 24 04.12.2015 10:20:55
For the pocket mounting of a preassembled temperature sensor please remove the O-ring and the extension ring .6 5
1. Temperatur sensor identificationBLUE (Return): for body TKSRED (Flow): for ball valve / tee
2. Sensor-bolt (brass-screwing)
3. O-ring black (auxiliary member for mounting)4. Grooves for the immersion depth of the sensor (3 x)5. Extension ring (no. 21520)6. O-ring green (seal)
1 2
3 6
54
Try the steps R1 - R3 in succession to ensure from the illustrated positionsof the black O-ring in the 3 grooves of the temperature sensor, that the sensor is in the pocket up to the stop (x) and the TF-bolt picks the threadof the pocket R4 !
-
R1 R2 R3 R4
x x
25
Wall-mounted installation with removable calculator
c
a
max. 3
0 cm
Wind up surplus cable hear.
Variants with removable calculator can be up to max. 30 cm away from the flow sensor using the optional wall bracket (Art. No. 11012).
(1) Use the materials supplied to fix the wall bracket (a) in the required position. Align the wall bracket so that the groove (b) points upwards.
(2) Fit the cover (c) so that the "TOP1" marking can be read horizontally, and latch it into the wall bracket.
(3) Remove the calculator (d) from the flow sensor (e), wind up the surplus calculator cable.
(4) Insert the calculator (d) into the wall bracket so that it noticeably latches.b
d
e
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 25 10.02.2015 09:44:55
26
Check the installation
Open the shut-offs
Check for leaks and check flow direction
• Open the ball valves• Switch on the heating and• open the radiator valve
• Check for leaks and check flow direction
Incorrect flow direction is shown on the display.
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 26 10.02.2015 09:44:56
27
(1) Thread the sealing wire through the sealing holes in the nit, the sensor union fitting, the shut-off valve and the housing.
(2) Push the wire through the opening in the seal body and pull tight.(3) Fold over the seal fastening and press firmly into the seal housing with a
clearly audible click so that it is completely flush!(4) Cut off any surplus seal wire.
Sealing the instrument
Sealing the flow sensor
Sealing the temperature sensor in the ball valve
(1) Thread the wire of the seal through the seal drill hole on the ball valve and the sensor connection.(2) Stick the seal through the free opening.(3) Wind the wire tightly by turning the blade of the seal.(4) Break off the blade of the seal.Sealing is ensured once the blade is broken off.
3
4
(1) Thread the wire of the seal through the seal drill hole of the union nut at the inlet and the flow sensor.(2) Stick the seal through the free opening. Wind the wire tightly by turning the blade of the seal.(3) Break off the blade of the seal. Sealing is ensured once the blade is broken off.
1
2
3
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 27 10.02.2015 09:44:56
28
Sealing the instrument
Note the installation date, meter num-bers, and seal numbers, Note the old and new meter readings.
Handover record available on:www.deltamess.de
Sealing the temperature sensor in the pocket
(1) Thread the sealing wire through all the holes in the temperature sensor holders, around the tee and back through one hole.
(2) Push the wire through the opening in the seal body and pull tight.
(3) Fold over the seal fastening and press firmly into the seal housing with a clearly audible click so that it is completely flush!
• Remove installation protection
Observe national and country-specific regulations concerning the use of pockets
(thermowells)!
Dispose of the old instru-ment according to the national regulations!
Note the meter readings
5
1
2
3
4
(1) Thread the wire of the seal through the seal drill hole of the sensor connection and immersion sleeve.(2) Guide the seal wire around the T piece. (3) Stick the seal through the free opening.
(4) Wind the wire tightly by turning the blade of the seal.
(5) Break off the blade of the seal.
Sealing is ensured once the blade is broken off.
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 28 10.02.2015 09:44:56
29
Instrument elements
Status displays
(1) By default, the display is always off (sleep mode). Briefly press the key <H> or <V> tobring up the display loop to the quick reading. Press the key <H> or <V> for morethan 3 seconds to call up the plane operating display diagramm.(2) < H > key (horizontal)(3) < V > key (vertical)(4) IrDA interface(5) Interface cover(6) Module interface(7) Mounting holes for external optical
modules(8) User protection and slots for external
cable connections
Controls and interfaces
Display DescriptionThe data displayed applies to:• Heat = heating• Cool = cooling
• Monthly pulse input 1 values• Monthly pulse input 2 values
• (empty) = Displayed value is a current value• M (Memory) = Value on a monthly or reference date
Displayed value is a date value:• Day = Current date (today)• M-Day = Date applies to a saved annual
or monthly valueDisplayed value is a check number:• Check = Check number refers to the current consumption value• M-Check = Check number applies to a saved
annual or monthly value
• • No energy metering -> no temperature difference
• • Energy metering
• IrDA communication is currently active
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_041215_EN.indd 29 04.12.2015 12:12:56
30
Error display Error description Measures/Notes• Hardware fault or
damaged firmware• Check flow sensor, connection cable
and calculator for external damage• Instrument must be replaced
• Add-on module was paired with another meter before
• The module has the measuring data of another heat meter
• Save data, since these are overwritten after a short time
• Press any key to delete the display• Flow sensor
broken• Check temperature sensor and pipes
for mechanical damage• Instrument must be replaced
• Flow sensor short-circuit
• Check temperature sensor and pipes for mechanical damage
• Instrument must be replaced
• Return sensor brocket
• Check temperature sensor and pipes for mechanical damage
• Instrument must be replaced
• Return sensor short-circuit
• Check temperature sensor and pipes for mechanical damage
• Instrument must be replaced
Special operating statesDisplay Description Measures/Notes
• Communication credit of the module interface or IrDA exceeded
• Is corrected after the credit period (module = current day; IrDA = current month) has expired.
• Operating time expired • Instrument must be replaced
• Incorrect flow direction • Check installation (note arrow on flow sensor)
• Check piping• Check recirculation pumps and thermo-
stats are functioning correctly• Temperature sensors
have been mixed up or fitted incorrectly
• Check whether flow sensor has been fitted in the right pipe run or
• check type of temperature sensor installation
Display
Error messages
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 30 10.02.2015 09:44:57
31
Key assignment in programming modeTo activate programming mode, you must prove you have the necessary programming permission by entering a PIN.
The preset default PIN is printed on the instrument packaging.If the PIN has been accepted, further values can be programmed without PIN input. Validity is lost if a level other than L3 or L4 is set.
1. Activate programming mode
Use the < H > key to navigate to the level.
Use the < V > key to navigate within the level to display the value to be parameterised.
(Key shortcut) Press and keep pressed the < H then press and keep pressed < V > key too.
2. Change parameters
section has reached the required value.
(Key shortcut) Press and keep pressed the < H then press and keep pressed < V > key too.
1. Activate LC displayPress the < H > key or
Press the < V > key for more than 3 seconds
2. Switch from any position in a level to the next levelPress the < H > key
3. Switch to the next display within a levelPress the < V > key
(level L3 or L4 only)
Key assignments
Key assignment for default level
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_041215_EN.indd 31 04.12.2015 12:21:57
32
Putting into use
Display level L3 - "Reference date" display1. Use the shortcut < H > + < V > (see Seite 31) to activate programming mode.
If programming mode is activated, the segment block for set-ting the "Year" value flashes first.
2. Briefly press the < V > key until the "Year" value for the new reference date has been reached.
3. Press the <V> key only if you want to skip the first reference date.Press the < H > key to skip to the segment block for setting the "Month" value.
4. Briefly press the < V > key until the "Month" value for the new reference date has been reached.
5. Confirm the setting using the shortcut < H > + < V > (see Seite 31).
1. Use the < H > key to navigate to the relevant display level (L3 or L4).
2. Use the < V > key to navigate to the display of the relevant value (here reference date).
3. Use the key shortcut < H >+< V > (see page 31) to activate programming mode. Keep this key shortcut pressed until the display for the password entry appears.
4. Briefly press the < V > key repeatedly, until the value for the flashing segment block is reached.
5. Press the < H > key to jump to the next segment block.
6.Repeat steps 4 and 5 until the password has been entered com-pletely.
7. Confirm acceptance of the password with the shortcut < H >+< V > (see Seite 31). If the correct password has been en-tered the display switches to the value to be programmed.
Example: Programming the reference date
Activate programming mode
Only the last day of a month can be selected as the reference date.
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 32 10.02.2015 09:44:57
33
Putting into use
Display level L3 - display of "possible + active levels"
1. Use the shortcut < H > +< V > (see Seite 31) to activate programming mode. If programming mode is activated, the "M-" symbol flashes.
If the marking is not set on the "M-" symbol, briefly press the < H > key until the "M-" symbol flashes.
2. Briefly press the < V > key, if the "display check number" option is to be switched on or off.
3. Confirm the setting using the shortcut < H > + < V > (see Seite 31).
Display level L3 - display of "possible + active levels"1. Use the shortcut < H > +< V > (see Seite 31)
to activate programming mode. If programming mode is activated, the "M-" symbol flashes.
2. Briefly press the < H > key repeatedly, until the segment block for the setting of the relevant level flashes.
3. Briefly press the < V > key, to activate or deactivate the relevant level to.
4. Briefly press the < H > key to jump to the digit of the next available level.
5.Repeat steps 3 and 4, until the required levels are activated/deactivated.If display level 3 has been deactivated, the instrument can only be parameterised using the parameterising software!
6. Confirm the setting using the shortcut < H > + < V > (see Seite 31).Result from this example:Levels 2, 3, 4 and 5 are shown, = level 6 is hidden,
2 x spaces = levels 7+8 not available, = level 9 hidden
Example: Activating / deactivating levels
Example: Switch the check number display on / off (postcard readout)
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 33 10.02.2015 09:44:57
34
Putting into use
Display level L3 - display of "possible + active levels"
1. Use the shortcut < H > +< V > (see Seite 31) to activate programming mode. If programming mode is activated, the "M-" symbol flashes.
2. Briefly press the < H > key repeatedly until the symbol of the dimensional unit flashes with the decimal frame.
3. Briefly press the < V > key, to change the dimensional unit.
4. Confirm the setting using the shortcut < H > + < V > (see Seite 31).
Example: Change the dimensional unit (kWh <-> MWh or MJ <-> GJ)
All other instrument parameters can be set as shown in the examples of the given examples.
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 34 10.02.2015 09:44:58
35
Installation suggestions
1
2
(1) Installation in the area of the secondary circuit not continuously flowed through.
(2) Installation in the area of the primary circuit not continuously flowed through. The heat meter is only flowed through if hot flow water flows from the prima-ry circuit into the secondary circuit via the three-way mixing valve.
3
4
5
(3) Installation in the area of the secondary circuit not continuously flowed through.
(4) Installation in the area of the secondary circuit continuously flowed through.
(5) Installation in the primary circuit.
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 35 10.02.2015 09:44:58
36
Checklist
Before the installation
1. Are the sealing points on the measuring instrument undamaged? (seal on return sensor, seal) £
2. Is a suitable installation kit available? (Ball valves, built-in parts, seals) £
3. Is the installation kit positioned correctly? £4. Is the heat meter dimensioned correctly?
(flow qi/qp/qs, pressure, temperature) £5. Are the geometric connection conditions of the flow sensor, the temper-
ature sensor and any pockets suitable for the installation position? £6. For the case in which pockets are used:
Are the pockets suitable for the heat meter with regard to country-spe-cific and national regulations?
£
7. Are all necessary built-in parts available? (seals, union fittings) £
8. Are all the parts required for sealing available? £
9. Are the installation instructions for the heat meter available? £10. Has the system been flushed properly?
(Clean filter and screens) £
Observe national and country-specific regulations!
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 36 10.02.2015 09:44:58
37
Following installation
1. Are the temperature sensors (flow/return sensor) installed in the rele-vant pipes? £
2. In addition, if using pockets: Is the sensor pushed in up to the bottom of the pocket and tightly screwed in place?
£
3. Is the flow sensor installed in the correct pipe run? £4. Is the flow sensor installed free from stresses?
(No tensile, compressive or torsional loads) £
5. Are the shut-off devices open in the correct pipe run? £
6. Are all installation positioned sealed tight? £7. Are all displays plausible?
(Temperatures and instantaneous flow) £
After putting into use
1. Is the flow sensor sealed? (Risk of tampering) £
2. Are the return sensor and the flow sensor sealed? £
3. Is the instrument number noted (on the nameplate)? £4. Is the initial meter reading noted?
(Level 0, important for billing) £5. Has the handover record been filled?
(Available on www.deltamess.de) £
Checklist
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 37 10.02.2015 09:44:58
38
Notes on heat meter add-on modules
With the introduction of the new heat meter generation, the housing colour of the heat meter add-on modules has been changed from blue to white.
In addition, the serial number concept has been optimised for the new heat meters.
Note the following instructions:The add-on modules listed below use the < Serial No. > to interpret the < Sys-tem ID channel 2 > using an algorithm that is invalid for the serial number con-cept of the new heat meters.
Cooling serial No.
Heat serial No.
This means that these add-on modules return a value for the address allocation of the 2nd channel (< System ID channel 2 >) that no longer matches the cool-ing serial no. printed on the meter.
This results in the following pecularities for modules to date in combination with a combined heat/cooling meter:WFZ16x.Ox - add-on radio moduleCalibration replacement (blue add-on module)The add-on module returns the following value as the System ID channel 2 < Serial No. for heat - 3,000,000 >Example:Printed on the heat meter: Serial no. for heat: 65 000 100 Serial no. for cooling: 65 000 101
Use of combined heat/cooling meters with add-on module
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 38 10.02.2015 09:44:58
39
Notes on heat meter add-on modules
The following system IDs are generated from the serial no. for heat: System ID channel 1: 65 000 100 for heat System ID channel 2: 62 000 100 for coolingThe combined heat/cooling meter is identified and managed in the Q AMR and Q walk-by radio systems on the basis of these numbers.
With the < System ID channel 2 > generated by the module, there is a risk of an address conflicting with other instruments in the radio network. To prevent the risk of data loss, check the instruemnt directory for channel 2 system IDs that occur more than once!
We offer the following solution so that address conflicts can be excluded from the outset:The WFZ.PS3 programming stick can be used to parameterise the module to the serial number algorithm of the Q heat 5.
The WFZ.PS3 programming stick is available on request.
R99/0005-02 - add-on M-Bus moduleNew installation and calibration replacement (white and blue add-on module)For the < System ID channel 2 > the module sets a “9” as the first digit. Posi-tions 2 - 8 correspond to those of the serial number for heat.Example:Printed on the heat meter: Serial no. for heat: 65 000 100 Serial no. for cooling: 65 000 101The following system IDs are generated from the serial no. for heat: System ID channel 1: 65 000 100 for heat System ID channel 2: 95 000 100 for cooling
30186-3 Kompakt-WMZ TKS-WM Installationsanleitung_130115_EN.indd 39 10.02.2015 09:44:58
40
DELTAMESS DWWF GmbH Sebenter Weg 4223758 Oldenburg in Holstein, GermanyPhone 00 49 (0) 43 61/ 51 14-0Fax 00 49 (0) 43 61/ 51 14-88
www.deltamess.de
Compact heat meter Deltamess Type: TKS-WM Document No.: 30186-4 Source: DM_Installation instructions Issue date: 18.09.2015 Issue status: 09.15
40
30186-4 Kompakt-WMZ TKS-WM Installationsanleitung_041215_EN.indd 40 04.12.2015 12:13:58