Series SYJ300/500/7003 Port Solenoid Valve
Improved pilot valvePilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M2.
�Flow Characteristics
SYJ300SYJ500SYJ700
0.361.2 2.7
0.310.410.38
0.0890.32 0.72
SeriesFlow characteristics
C [dm3/(s·bar)] b Cv
Cover (stainless steel)
Rubber Seal
1369
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1369
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SYJ300
SYJ500
SYJ700
SYJ300
SYJ500
SYJ700
M3 x 0.5
M5 x 0.8
1/8
M5 x 0.8
1/8
1/8, 1/4
Series Port sizeSonic
conductanceC [dm3/(s·bar)]
Type ofactuation Voltage Electrical entry
Option
Light/surge voltage suppressor
Manualoverride
Variations
Note) All AC voltage models have built-in surge voltage suppressor.
Bo
dy
po
rted
Bas
e m
ou
nte
d
–+
–+
–+
P.1372
P.1386
P.1404
P.1404
P.1372
P.1386
1370
Series SYJ300/500/700
Rubber Seal3 Port Solenoid Valve
�N.C.�N.O.
Effective area0.9 mm2
2→3(A→R)
0.662→3
(A→R)
2.52→3
(A→R)
1.22→3
(A→R)
2.72→3
(A→R)
� Non-locking push type
� Push-turn locking slotted type
� Push-turn locking lever type
For DC
� With surge voltage suppressor
� With light/surge voltage suppressor
For DC
� 24 VDC12 VDC6 VDC5 VDC3 VDC
For ACFor AC
� With light/surge voltage suppressor
�100 VAC Hz110 VAC Hz200 VAC Hz220 VAC Hz
Note)
Grommet
L plugconnector
M plugconnector
DIN terminal
M8 connector
(SYJ500, 700 only)
0.362→3
(A→R)50
6050
6050
6050
60
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1370
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Body ported
Base mounted
Body ported
Base mounted
Body ported
Base mounted
1371
Series SYJ300/500/700
SYJ300
SYJ500
SYJ700
SYJ300
SYJ500
SYJ700
ø8
Manifold Variations
Valve series A portlocation
Top
Top
Top
Side
Side
Side
Bottom
Bottom
M5 x 0.8
1/8
1/8
1/8
1/4
M5 x 0.8
1/8
1/8
1/8
1/4
1/4
P, R portssize
A port size
With one-touch fitting
Applicable tubing O.D.
ø6ø4 N3 N7 N9
Note 1) Only for internal pilotNote 2) Only for external pilot
Note 1)
Note 1)
Note 1)
Note 2)
Note 1)
M3 M5 1/8
Bo
dy
po
rted
Bas
e m
ou
nte
d
P.1378
P.1392
P.1410
P.1378
P.1392
P.1410
Series SYJ300 Series SYJ500 Series SYJ700
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1371
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
JIS Symbol
SYJ31 24 SYJ32 2
4
SYJ31 R24 SYJ32 R2
4
X X
(A)2
(A)2
1(P)
3(R)
(A)2
1(P)
3(R)
1(P)
3(R)
(A)2
1(P)
3(R)
1372
Series SYJ300Rubber Seal3 Port Pilot Solenoid Valve
Specifications
Fluid
Operating pressure range (MPa)
Ambient and fluid temperature (°C)Response time ms (at 0.5 MPa) Note 1)
Max. operating frequency (Hz)
Manual override (Manual operation)
Pilot exhaust method
LubricationMounting orientationShock/Vibration resistance (m/s2) Note 2)
Enclosure
Air
0.15 to 0.7Internal pilot
–10 to 50 (No freezing. )
15 or less
10
Non-locking push type, push-turn locking slottedtype, push-turn locking lever type
Not required
Unrestricted
150/30
Dust proof (∗ M8 connector conforms to IP65.)
Individual exhaust for the pilot valve,common exhaust for the pilot and main valve
∗ Based on IEC60529Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated
voltage, without surge voltage suppressor.)Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at
the right angles to the main valve and armature in both energized and de-energized states every once for each condition.(Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Value in the initial state)
Body ported
Base mounted
Internal pilot
External pilot
Made to Order(For details, refer to pages 1422 to 1423.)
Solenoid Specifications
Electrical entry
Coil rated voltage (V)
DCAC 50/60 Hz
Standard With powersaving circuit
Surge voltage suppressorIndicator light
Power consumption (W) DC
Apparent power(VA) ∗ AC
100 V
110 V[115 V]
200 V
220 V[230 V]
24, 12, 6, 5, 3
100, 110, 200, 220
±10% of rated voltage ∗
0.35 (With light: 0.4)
0.1 (With light only)
0.78 (With light: 0.81)
1.18 (With light: 1.22)
0.86 (With light: 0.89)[0.94 (With light: 0.97)]
1.30 (With light: 1.34)[1.42 (With light: 1.46)]
Diode (varistor when non-polar types)
LED
Grommet (G), (H), L plug connector (L),M plug connector (M), M8 connector (W)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.∗ S, Z and T type (with power saving circuit) should be used within the following allowable
voltage fluctuation range due to a voltage drop caused by the internal circuit.S and Z type: 24 VDC: –7% to +10%
12 VDC: –4% to +10%T type: 24 VDC: –8% to +10%
12 VDC: –6% to +10%
Allowable voltage fluctuation
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1372
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1373
Rubber Seal3 Port Pilot Solenoid Valve Series SYJ300
External Pilot
SYJ300RPilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port.It can be used in the vacuum (up to –100 kPa) or low pressure line with 0.15 MPa or less.
External pilot pressure
Main pressure
SpecificationsApplicable model
Operating pressure range
MPa
Base mounted (SYJ314R, SYJ324R)
Note 1) For manifold base, refer to page 1378.Note 2) External pilot type body ported valves (SYJ3�2R) can only be used on the manifold.
–100 kPa to 0.7
0.15 to 0.7
Flow Characteristics/Mass
Note) Value for DC. Add 1 g for AC. ( ): Without sub-plate.
SYJ312SYJ322SYJ314SYJ324
C [dm3/(s bar)] b Cv C [dm3/(s bar)] b Cv1→2 (P→A) 2→3 (A→R) Valve model
Flow characteristics Mass (g) Note)
Type ofactuation
Portsize
M3 x 0.5
Grommet
32
53 (32)
L/M plugconnector
33
54 (33)
M8connector
37
58 (37)M5 x 0.8
N.C. ––
0.410.36
––
0.180.31
––
0.0860.089
––
0.350.36
––
0.330.31
––
0.0860.089
N.O.N.C.N.O.
Bodyported
Base mounted(with sub-plate)
0.9
–
Effectivearea (mm2)
P, R portM5 x 0.8
Mark
X port (External pilot)M5 x 0.8
A portM5 x 0.8
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1373
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
(For manifold type 20, 20R)
SYJ3 2 5 M M3
SYJ3 4 5 M
1
1
3 port
3 port
Body option
BracketNil: Without bracket
F : With bracket
Port size
Manual override
Electrical entry
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC
Bracket
Body ported
Base mounted
∗ CE-compliant: For DC only.
Note) When placing an order for body ported solenoid valve as a single unit, mounting screws for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to page 1379.)
-+
–+–+
–+
+– +–
NilQ
—CE-complaint
CE-complaint
∗ LN, MN type: with 2 sockets.∗ Refer to page 1425 for the lead wire length of L and M plug connectors.∗ Refer to page 1428 for the connector assembly with cover for L and M plug connectors.∗ For connector cable of M8 connector, refer to page 1429.∗ A M8 connector conforming to IEC60947-5-2 is also available. Refer to page 1422 for details.Note 1) Enter the cable length symbols in �. Please be sure to fill in the blank referring to page 1429.
How to Order
1374
Series SYJ300
12
Normally closedNormally open
Type of actuation
56VSR
24 VDC12 VDC6 VDC5 VDC3 VDC
Rated voltageDC
1234
100 VAC200 VAC110 VAC [115 VAC]220 VAC [230 VAC]
AC (50/60 Hz)
∗ For type W�, DC voltage is only available.
NilSZRU
Without light/surge voltage suppressor With surge voltage suppressor
With light/surge voltage suppressor With surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)
Light/surge voltage suppressor
∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit.
∗ For type R, U, DC voltage is only available.∗ Power saving circuit is only available in the "Z" type.
∗ Bracket is mounted.∗ Brackets cannot be retrofitted.∗ External pilot type is not available.
For sub-plate style, manifold type 41, S41, 42, S42, 42R, S42R
Nil: Individual pilot exhaust type
M: Common exhaust for the pilot and main valve
R: External pilot type∗
Pilot valve exhaust is centralized to main valve.
R port P, E port
R port P, E port
∗ SYJ3�2R is only for manifold use.
Nil
T
Standard With power saving circuit
(24, 12 VDC only)
Coil specifications
∗ Power saving circuit is not available in the case of W� type.
Grommet L plug connector M plug connector M8 connector
G: Lead wire length 300 mm
L: With lead wire (Length 300 mm)
M: With lead wire (Length 300 mm)
MN: Without lead wire
WO: Without connector cable
H: Lead wire length 600 mm
LN: Without lead wire
LO: Without connector
MO: Without connector
W�: With connector cable Note 1)
Nil: Without sub-plate
(With gasket and screws)
M5: M5 portWith sub-plate
Nil: Non-locking push type
D: Push-turn locking slotted type
E: Push-turn locking lever type
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1374
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
V111
GHL
LNLOM
MNMOWOW�
How to Order Pilot Valve Assembly
5 G
Electrical entryGrommet, 300 mm lead wireGrommet, 600 mm lead wire
With lead wireWithout lead wireWithout connectorWith lead wireWithout lead wireWithout connectorWithout connector cableWith connector cable Note 1)
e tq r
u
w
y
e tq r
u
y
w
(A)2
1(P)
3(R)
(A)2
1(P)
3(R)
N.C. N.O.
Since V111 is CE-compliant as standard, the suffix "-Q” is not necessary.
Note) Add suffix “-Q” for the CE-compliant product.
3(R)
1(P)
(A)
2
3(R)
1(P)
(A)
2
∗ For connector cable of M8 connector, refer to page 1429.
Note 1) Enter the cable length symbols in �. Please be sure to fill in the blank referring to page 1429.
1375
Rubber Seal3 Port Pilot Solenoid Valve Series SYJ300
Construction
Component Parts Replacement PartsNo.12345
DescriptionBodyPiston plateEnd coverPistonSpool valve assembly
MaterialZinc die-casted
ResinResinResin
Aluminum, H-NBR
NoteWhiteWhiteWhite
––
No.67
DescriptionSub-plate Note)
Pilot valve
NoteZinc die-casted
Part no.SYJ300-9-1(-Q)V111(T)-����
Nil
T
StandardWith power
saving circuit (24, 12 VDC only)
Coil specifications
∗ Power saving circuit is not available in the case of W� type.
56VSR12
3
4
Rated voltage24 VDC12 VDC6 VDC5 VDC3 VDC
100 VAC 50/60 Hz200 VAC 50/60 Hz110 VAC 50/60 Hz
[115 VAC 50/60 Hz]
220 VAC 50/60 Hz[230 VAC 50/60 Hz]
∗ For type W�, DC voltage is only available.
∗ CE-compliant: For DC only.
Light/surge voltage suppressorWithout light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressorWith surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)
∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit.
∗ For “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the “Z” type.
NilSZRU
L plug connector
M plug connector
M8 connector
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1375
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
∗ Refer to page 1429 for dimensions with connector cable.
2
6.7
12.6
3.2
-+
28.4
22
16.4
10
22.1
15
(2)
12.6
22.1
13.5
15
(2)
43.7
22.1
13.5
15
57.6
(2)
50.2
32.5
15
22.1
13.5
15
2
11 10
79.2
12.622
.1
15
13.5
7.17.4
8.2
- +
26.4
12.7
P R
A
Series SYJ300
1376
Grommet (G), (H): SYJ3�2-�GH ��-M3
Body Ported
With bracket: SYJ3�2-�G
H ��-M3-F
∗ [ ] for AC
48.6
[50.
8]
28 [35]
2 x ø3.5(For mounting)
(Bracket)
48.6 [50.8]
28 [3
5]
M3 x 0.5(A port)
ø1.2(PE port)
G: Approx. 300H: Approx. 600
(Lead wire length)
(Light/surge voltage suppressor)
M3 x 0.5(P, R port)
Manual override
2 x ø1.8(For manifold mounting)
L plug connector (L): SYJ3�2-�L��-M3
M plug connector (M): SYJ3�2-�M��-M3
M8 connector (WO): SYJ3�2-�WO��-M3
58.5
[60.
7]A
ppro
x. 3
00(L
ead
wire
leng
th)
28 [35]
48.7
[50.
9]
Approx. 300(Lead wire length)
39.1 [46.1]
M8 x 1
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1376
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
14
10
52.
5
11
26.4
17 3
A
13
17.5
26.1
10
+-
5
23
10 8.6
35.6
28.5
R P
5
7.5
X
M5 x 0.8(A port)
48.6 [50.8]G: Approx. 300H: Approx. 600
(Lead wire length)
Manual override
2 x ø3.2(For mounting)
41.5
[48.
5]
(Light/surge voltage suppressor)
M5 x 0.8(P, R port)
M5 x 0.8(X port)
26.1
5
23 108.
6
RP
35.6
28.5
43.7
5
23 108.
6
RP
35.6
28.5
57.6
50.2
46
28.5
5
23 108.
6
RP
35.6
28.5
∗ Refer to page 1429 for dimensions with connector cable.
1377
Rubber Seal3 Port Pilot Solenoid Valve Series SYJ300
Grommet (G), (H): SYJ3�4-�GH ��-M5
Base Mounted (With Sub-plate) ∗ [ ] for AC
L plug connector (L): SYJ3�4-�L��-M5
M plug connector (M):SYJ3�4-�M��-M5
M8 connector (WO):SYJ3�4-�WO��-M5
App
rox.
300
(L
ead
wire
leng
th)
58.5
[60.
7]
41.5 [48.5]
Approx. 300 (Lead wire length)
52.6 [59.6]
48.7
[50.
9]
M8 x 1
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1377
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1378
Manifold SpecificationsSeries SYJ300
Manifold Specifications
Model
Manifold type
P (SUP), R (EXH)
Valve stations
A portPorting specifications
Port size
For internal pilot
For external pilot
Type 20
Type 20R
Type 41, S41 Type 42, S42
Type 42R, S42R
Location
Direction
P, R port
A port
X port Note)
Valve
Top
M3 x 0.5
M5 x 0.8
M5 x 0.81/8 M5 x 0.8
M3 x 0.5
Single base/B mount
Common SUP/Common EXH
2 to 20 stations
Base
Side1/8
M5 x 0.8
M5 x 0.8C4 (One-touch fitting ø4)
Note) Only for external pilot
How to Order Manifold (Example)
Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.
(Example)SS3YJ3-20-03 ............. 1 set (manifold base)
SYJ312-5LZ-M3 ......... 2 sets (valve)
SYJ300-10-1A ............. 1 set (blanking plate assembly)
SS3YJ3-42R-03-C4 .... 1 set (manifold base)
SYJ314R-5G ............... 2 sets (valve)
SYJ300-10-2A ............. 1 set (blanking plate assembly)
Flow Characteristics
Note) Value at manifold base mounted, 2 position single acting
Type SS3YJ3-20
Type SS3YJ3- 41 S41
Type SS3YJ3-42-M5
Type SS3YJ3-20R
Type SS3YJ3-42-C4
Type SS3YJ3-42R-M5Type SS3YJ3-42R-C4
Type SS3YJ3-S42R-M5Type SS3YJ3-S42R-C4
Type SS3YJ3-S42-M5Type SS3YJ3-S42-C4
C [dm3/(s·bar)]
1(P), 3(R)Port
2(A)Port b Cv
C [dm3/(s·bar)] b Cv
1→2 (P→A) 2→3 (A→R)Manifold
Flow characteristicsEffective
area (mm2)
Port size
M5 x 0.8
M5 x 0.8
1/8
1/8
M3 x 0.5
C4
M3 x 0.5
M5 x 0.8
M5 x 0.8C4
M5 x 0.8C4
M5 x 0.8C4
M3 x 0.5
–
–
0.310.330.320.35
–
0.310.330.320.35
–
–
–
–
0.0750.0860.0790.082
–
0.0750.0860.0790.082
–
–
0.320.330.330.35
–
0.320.330.330.35
–
–
0.110.2 0.350.26
–
0.110.200.350.26
–
–
0.0720.0820.0860.086
–
0.0720.0820.0860.086
0.9
1.5
––––
0.9
––––
1/8
1/8
1/8
SYJ3�2
SYJ3�4
SYJ3�4
SYJ3�4
SYJ3�2R
SYJ3�4R
SYJ3�4R
Body portedfor internal pilot
Base mountedfor internal pilot
Body portedfor external pilot
Base mountedfor external pilot
0.170.360.30.17
–
0.170.360.300.17
∗∗
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1378
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Body ported (Type SYJ3�2(R)(-Q))
Base mounted (Type SYJ3�4(R)(-Q))
Part no.: SYJ300-10-1A(-Q) Part no.: SYJ300-10-2A(-Q)
Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blanking Plate Assembly
P A
Applicable baseSS3YJ3-20(-Q)SS3YJ3-20R(-Q)
Applicable base Sub-plate SS3YJ3-41(-Q)SS3YJ3-S41(-Q)SS3YJ3-42(-Q)SS3YJ3-S42(-Q)SS3YJ3-42R(-Q)SS3YJ3-S42R(-Q)
Applicable base SS3YJ3-20(-Q)SS3YJ3-20R(-Q)
Applicable base Sub-plate SS3YJ3-41(-Q)SS3YJ3-S41(-Q)SS3YJ3-42(-Q)SS3YJ3-S42(-Q)SS3YJ3-42R(-Q)SS3YJ3-S42R(-Q)
Manifoldbase
Manifoldbase
Manifoldbase
Manifoldbase
P
Manifold gasket SYJ300-5-6
Manifold gasket
A
Round head combination screwSY100-33-3
(M1.7 x 17, Matt nickel plated)
Round head combination screwSY100-33-3
(M1.7 x 17, Matt nickel plated)
Round head combination screw
Round head combination screw
Blanking plate
Blanking plate
Manifold gasket
P
A
Manifold gasket SYJ300-5-4
Note) Add suffix “-Q” for the CE-compliant product.
1379
Rubber Seal3 Port Pilot Solenoid Valve Series SYJ300
CautionMounting screw tightening torques
M1.7: 0.12 N·m
Use caution to the assembly orientation for solenoid valves, gasket and optional parts.
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1379
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Type 42R
How to Order
SS3YJ3 0520
How to Order
How to Order
Nil
F
Without bracket
With bracket
Bracket
M5
C4
N3
M5 x 0.8
ø4 one-touch fitting
ø5/32" one-touch fitting
A port size
How to Order
M5
C4
N3
M5 x 0.8
ø4 one-touch fitting
ø5/32" one-touch fitting
A port size
Pilot valve is opposite the A port side.
Pilot valve is on the A port side.
Valve mountingdirection
S
Nil
02
:
20
2 stations
:
20 stations
Stations
Stations
Stations
02
:
20
2 stations
:
20 stations
Stations
Nil
F
N
T
Rc
G
NPT
NPTF
P, R portthread type
02
:
20
2 stations
:
20 stations
Stations
Valve mounting direction
Nil
00F
00N
00T
Rc
G
NPT
NPTF
P, R portthread type
Nil
F
N
T
Rc
G
NPT
NPTF
P, R portthread type
Pilot valve is opposite the A port side.
Pilot valve is on the A port side.S
Nil
Valve mounting directionPilot valve is opposite the A port side.
Pilot valve is on the A port side.S
Nil
Nil
Q
—
CE-complaint
CE-complaint
Nil
Q
—
CE-complaint
CE-complaint
Nil
Q
—
CE-complaint
CE-complaint
Nil
Q
—
CE-complaint
CE-complaint
Nil
Q
—
CE-complaint
CE-complaint
SS3YJ3 41 05 M3
SS3YJ3 42R 05 M5
SS3YJ3 20R 05
SS3YJ3 42 05 M5
02
:
20
2 stations
:
20 stations
02
:
20
2 stations
:
20 stations
Applicable blankingplate assemblyRefer to page 1379.
Applicable solenoid valveSYJ314-����(-Q)SYJ314M-����(-Q)SYJ324-����(-Q)SYJ324M-����(-Q)
Applicable blankingplate assemblyRefer to page 1379.
Applicable solenoid valveSYJ314-����(-Q)SYJ314M-����(-Q)SYJ324-����(-Q)SYJ324M-����(-Q)
Applicable blankingplate assemblyRefer to page 1379.
Applicable solenoid valveSYJ312R-����-M3(-Q)SYJ322R-����-M3(-Q)
Applicable blankingplate assemblyRefer to page 1379.
Applicable solenoid valveSYJ314R-����(-Q)SYJ324R-����(-Q)
Applicable blankingplate assemblyRefer to page 1379.
Applicable solenoid valveSYJ312-����-M3(-Q)SYJ312M-����-M3(-Q)SYJ322-����-M3(-Q)SYJ322M-����-M3(-Q)
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
How to Order
Pilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port.It can be used in the vacuum (up to –100 kPa) or low pressure line with 0.15 MPa or less.
Note) For more than 8 stations, supply/exhaust air to/from both sides of P port and R port.
Note) For more than 10 stations, supply/exhaust air to/from both sides of P port and R port.
Note) For more than 8 stations, supply/exhaust air to/from both sides of P port and R port.
PR
Type 41
A
A PR
A
A
A
A
P
R
A
-+-+
-+-+
R
P
Type 42
P port
R port
A portM3 x 0.5
M5 x 0.8
M5 x 0.8
P port
R port
1/8
1/8
A portM3 x 0.5
P port
R port
M5 x 0.8
M5 x 0.8
A portM3 x 0.5
P portM5 x 0.8
A port
M5 x 0.8, C4 P port
R port
1/8
1/8
R portM5 x 0.8
A portM5 x 0.8, C4
XP
R
Type 20R
A portM3 x 0.5
P port
R port
1/8
1/8X port(External pilot)
M5 x 0.8
Type 42R(External pilot type)
R port
P port
1/8
1/8P port
R port
1/8
1/8
X port(External pilot)
M5 x 0.8
A portM5 x 0.8,C4
A portM5 x 0.8,C4
X port(External pilot)M5 x 0.8
A
AXP
R
A
A XP
R
-+-+
-+-+
1380
Manifold for External Pilot Type
Series SYJ300
Type 20
Manifold for Internal Pilot Type
Type 41 Type S41Pilot valve is on the A port side.
Type 42Type S42Pilot valve is on the A port side.( )
( )
Type S42RPilot valve is on the A port side and is of the external pilot type.( )
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1380
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
(2.3
)
(21.
7)
(17.
5)
10
3.5L2
(6)
26.4 12
.7
1.9
3.5
L1
L2
12.5
2
21
RR
PP
AAAAA
5
105
41.5
5
105
25
26.1
13
+- +- +- +- +-
1.9
26.1
1.9
43.7
46
28.5
57.6 50
.2
1.9
∗ Refer to page 1429 for dimensions with connector cable.
1381
Rubber Seal3 Port Pilot Solenoid Valve Series SYJ300
Type 20 Manifold: Top Ported/SS3YJ3-20- Stations -00� (-F)
Grommet (G)
∗ [ ] for AC
2 x ø3.5(For mounting)
M3 x 0.5(Bracket mounting screw)
48.6
[50.
8]A
ppro
x. 3
00
(Lea
d w
ire
leng
th)
(Pitch)P=10.5
2 x ø3.5(For mounting)
M3 x 0.5(A port)
Manual override
M5 x 0.8(P, R port)
41.5
[48.
5]
(Light/surge voltage suppressor)
(Station 1)(Station n)
L plug connector (L) M plug connector (M) M8 connector (WO)
App
rox.
300
(L
ead
wire
le
ngth
)
41.5 [48.5]
58.5
[60.
7]
52.6 [59.6]Approx. 300 (Lead wire
length)
48.7
[50.
9]
M8 x 1
Station nL1L2
235.528.5
34639
456.549.5
56760
677.570.5
78881
898.591.5
9109102
10119.5112.5
11130123
12140.5133.5
13151144
14161.5154.5
15172165
16182.5175.5
17193186
18203.5196.5
19214207
20224.5217.5
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1381
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
26.1
+- +- +- +- +-
3.5
L1
L2
11
26.6
12.5
PR
PR
4.5
22
513
11.5
A A
1310
13.5
AA26.1
+- +- +- +- +-
22
11
12.5
3.5L2
L1
26.6
PR
PR
57.8
50.4
46
28.5
43.9
26.1
∗ Refer to page 1429 for dimensions with connector cable.
1310
1382
Series SYJ300
Type 41 Manifold: Side Ported/SS3YJ3-41- Stations -M3
SS3YJ3-S41- Stations -M3
Grommet (G)Type S41 Manifold: Side Ported(Pilot valve is on the A port side) /
∗ [ ] for AC
(Light/surge voltage suppressor)
App
rox.
300
(L
ead
wire
le
ngth
)
48.8
[51]
(Pitch)P=10.5
2 x ø3.5(For mounting)
Manual override
M5 x 0.8(P, R port)
(Pitch)P=10.5
41.5
[48.
5]
M3 x 0.5(A port)
(Station 1) (Station n)
(Pitch)P=10.5
M3 x 0.5(A port)
41.5
[48.
5]
(Pitch)P=10.5
App
rox.
300
(L
ead
wire
le
ngth
)
Manual override
48.8
[51]
2 x ø3.5(For
mounting)
(Station n) (Station 1)
L plug connector (L) M plug connector (M) M8 connector (WO)
52.6 [59.6]Approx. 300 (Lead wire
length)
48.9
[51.
1]
App
rox.
300
(L
ead
wire
le
ngth
)
58.7
[60.
9]
41.5 [48.5]
Station nL1L2
Station 235.528.5
34639
456.549.5
56760
677.570.5
78881
898.591.5
9109102
10119.5112.5
11130123
12140.5133.5
13151144
14161.5154.5
15172165
16182.5175.5
17193186
18203.5196.5
19214207
Station 20224.5217.5
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1382
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
33.1
+- +- +- +- +-
3617.5
11.5
12
8.5
4
20.5
L1L2
15.5
30.7
PR
PR
15.5
205AA
35.9
11.4
17.5
8.5
12
(4.4
)
15.5
205AA
4L2L1
3620
.5
15.5
30.7 P
R
PR
15.5
20533.1
AA
+- +- +- +- +-
35.9
11.4
17.5
8.5
12
(4.4
)
L14L2
15.5
15.5
205AA
+- +- +- +- +-
48.5 [55.5]
33.1
61.9
54.5
5335.5
∗ Refer to page 1429 for dimensions with connector cable.
1383
Type 42 Manifold: Side Ported/SS3YJ3-42- Stations -M5, �
Grommet (G)For M5 For � (Built-in one-touch fitting)C4
N3
C4N3 ∗ [ ] for AC
Rubber Seal3 Port Pilot Solenoid Valve Series SYJ300
(Light/surge voltage suppressor)
1/8(P, R port)
52.9
[55.
1]
(Pitch)P=10.5
App
rox.
300
(L
ead
wire
leng
th)
2 x ø4.5(For mounting)
Manual override
(Pitch)P=10.5
48.5
[55.
5]
M5 x 0.8(A port)
(Station 1) (Station n)
1/8(P, R port)
(Pitch)P=10.5
48.5
[55.
5]
One-touch fitting(A port)
Applicable tubing O.D.:ø4, ø5/32"
(Station 1) (Station n)
L plug connector (L) M plug connector (M) M8 connector (WO)
App
rox.
300
(L
ead
wire
leng
th)
62.8
[65]
59.6 [66.6]Approx. 300 (Lead wire length)
53 [5
5.2]
Grommet (G)For M5
For � (Built-in one-touch fitting)C4N3
Type S42 Manifold: Side Ported (Pilot valve is on the A port side) / SS3YJ3-S42- Stations -M5, �C4N3
52.9
[55.
1]
(Pitch)P=10.5
2 x ø4.5(For mounting)
(Station 1)(Station n)
App
rox.
300
(L
ead
wire
leng
th)
(Light/surge voltage suppressor)
(Pitch)P=10.5
48.5
[55.
5]
M5 x 0.8(A port)
1/8(P, R port)
(Light/surge voltage suppressor)
(Pitch)P=10.5
One-touch fitting(A, B port)
Applicable tubing O.D.:ø4, ø5/32"
(Station n) (Station 1)
Station nL1L2
Station 241.533.5
35244
462.554.5
57365
683.575.5
79486
8104.5 96.5
9115107
10125.5117.5
11136128
12146.5138.5
13157149
14167.5159.5
15178170
16188.5180.5
17199191
18209.5201.5
19220212
Station 20230.5222.5
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1383
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
12
8.5
36
17.5
11.5
PR
5
L3 8
18.5
4L2
2
30.7
17
20.5
5
L1
X X
A
X
A
X
A
X
A
X
A
X
33.1
20
+- +- +- +- +-
33.1
PR
48
PR
53
35.5
61.9 54
.5
PR
∗ Refer to page 1429 for dimensions with connector cable.
1384
Series SYJ300
Type 20R Manifold: Top Ported (External Pilot Type)/SS3YJ3-20R- Stations -00�
Grommet (G)
∗ [ ] for AC
1/8(P, R port)
52.9
[55.
1]
M5 x 0.8(X port)
(Pitch)P=10.5
App
rox.
300
(L
ead
wire
le
ngth
)
2 x ø4.5(For mounting)
M3 x 0.5(A port)
Manual override
48.5
[55.
5]
(Light/surge voltage suppressor)(Station 1)(Station n)
L plug connector (L) M plug connector (M) M8 connector (WO)
App
rox.
300
(L
ead
wire
le
ngth
)
62.8
[65]
48.5 [55.5]
59.6 [66.6]Approx. 300 (Lead wire
length)
53 [5
5.2]
M8 x 1
Station nL1L2L3
Station 247.539.531.5
3585042
468.560.552.5
5797163
589.581.573.5
7100 92 84
8110.5102.5 94.5
9121113105
10131.5123.5115.5
11142134126
12152.5144.5136.5
13163155147
14173.5165.5157.5
15184176168
16194.5186.5178.5
17205197189
18215.5207.5199.5
19226218210
Station 20236.5228.5220.5
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1384
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
33.1
+-+- +- +- +-
4
5
L1L2
20.55
8818.5
30.7
X X
XX X X X
12
8.5
3617.5
11.5
RP
205.
1
18.5
AA
35.9
11.4
12
8.5
17.5
(4.4
)
RP
20
18.5 5.1
AA
33.1
RP
48 RP
61.9
54.5
5335.5
RP
88
4L1L2
5
3620.55
18.5
30.7 X X
X X XXX
18.5
205.
1
33.1
AA
+- +- +- +- +-
18.5
205.
1
33.1
AA
+- +- +- +- +-
35.9
11.4
12
8.5
17.5R
P
(4.4
)
∗ Refer to page 1429 for dimensions with connector cable.
1385
Rubber Seal3 Port Pilot Solenoid Valve Series SYJ300
Type 42R Manifold: Side Ported (External Pilot Type)/SS3YJ3-42R- Stations -M5, �C4N3 ∗ [ ] for AC
Grommet (G)For M5 For � (Built-in one-touch fitting)C4
N3
(Light/surge voltage suppressor)
52.9
[55.
1]
(Pitch)P=10.5
App
rox.
300
(L
ead
wire
leng
th)
Manual override
1/8(P, R port)
(Pitch)P=10.5
48.5
[55.
5]
M5 x 0.8(A port)
(Station 1) (Station n)
1/8(P, R port)
(Pitch)P=10.5
48.5
[55.
5]
One-touch fitting(A port)
Applicable tubing O.D.:ø4, ø5/32"
(Station 1) (Station n)M5 x 0.8(X port)
2 x ø4.5(For mounting)
L plug connector (L) M plug connector (M) M8 connector (WO)
App
rox.
300
(L
ead
wire
leng
th)
62.8
[65]
48.5 [55.5]
59.6 [66.6]Approx. 300 (Lead wire length)
53 [5
5.2]
M8 x 1
Type S42R Manifold: Side Ported (Pilot valve is on the A port side) / SS3YJ3-S42R- Stations -M5, �
Grommet (G)For M5 For � (Built-in one-touch fitting)C4
N3
C4N3
52.9
[55.
1]
Manual override
App
rox.
300
(L
ead
wire
leng
th)
M5 x 0.8(X port)
2 x ø4.5 (For mounting)
(Pitch)P=10.5
48.5
[55.
5]
M5 x 0.8(A port)
(Station 1)(Station n)
(Pitch)P=10.5
48.5
[55.
5]
1/8(P, R port)
(Station n) (Station 1)
One-touch fitting(A port)
Applicable tubing O.D.:ø4, ø5/32"
(Pitch)P=10.5
Station 247.539.5
35850
468.560.5
57971
689.581.5
7100 92
8110.5102.5
9121113
10131.5123.5
11142134
12152.5144.5
13163155
14173.5165.5
15184176
16194.5186.5
17205197
18215.5207.5
19226218
Station 20236.5228.5
Station nL1L2
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1385
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SYJ 2 5 WAO M5
SYJ 4 5 WAO 01
15
5 1
12
Normally closedNormally open
Type of actuation
357
SYJ300SYJ500SYJ700
Series M501
M5 x 0.8 1/8 (SYJ700 only)
Port size
56VSR
24 VDC12 VDC6 VDC5 VDC3 VDC
Rated voltageDC
3 port(Manifold types 20, 20R, 21R)
3 port Body option
Nil
Bracket
Port size
Light/surge voltage suppressor
Body ported
Base mounted
Rc
NPTNPTF
G
Thread type
NT
FNil
Electrical entry
5 WAOV111
M8 connectorWAO Without connectorWA� With connector Note)
Note) Enter the cable length symbols in �. Please be sure to fill in the blank referring to page 1429.
Light/surge voltage suppressor
Electrical entry
Rated voltage
Nil Non-locking push typeD Push-turn locking slotted typeE Push-turn locking lever type
Manual override
Pilot valve individual exhaust
MCommon exhaust type for main and pilot valve
R External pilot∗ Nil Without sub-plate
SYJ500SYJ700
SYJ700
SYJ300
011/8 port
With sub-plate
M5M5 port
With sub-plate
021/4 port
With sub-plate
Nil Without bracketF With bracket
NilX20
—Body ported external pilot(Refer to page 1423.)
Made to Order
∗ X20 for Series SYJ300 is not available.
NilQ
—CE-complaint
CE-complaint
∗ SYJ3�2R, SYJ5�2R, SYJ7�2R are only for manifold use.
5 24 VDC6 12 VDCV 6 VDCS 5 VDCR 3 VDC
DC
Nil Without light/surge voltage suppressor With surge voltage suppressor
With light/surge voltage suppressor With surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)
SZRU
Nil Without light/surge voltage suppressor With surge voltage suppressor
With light/surge voltage suppressor With surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)
SZRU
WAO: Without connector
WA�: With connector Note)
Note) Enter the cable length symbols in �. Please be sure to fill in the blank referring to page 1429.
Since V111 is CE-compliant as standard, the suffix "-Q” is not necessary.
1422
M8 Connector Conforming to IEC60947-5-2Series SYJ300/500/700Made to Order
How to Order Valve
Sub-plate type, manifold types 40, 40R, 41, 41R, S41, 42, S42, 42R, S42R
How to Order Pilot Valve Assembly
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1422
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
How to Order Applicable solenoid valve series/SYJ5�2R, SYJ7�2R
SYJ 57 2R X20
Entry is the same as standard products.
X X(A)2
1(P)
3(R)
(A)2
1(P)
3(R)
Operating Pressure Range MPaOperating pressure range
Pilot pressure range
–100 kPa to 0.7
0.15 to 0.7
External Pilot Port
DimensionsSYJ500: 8 mm longer in total lengthSYJ700: 8 mm longer in total length
JIS Symbol
Body portedN.C. N.O.
Series
SYJ500, SYJ700
Port size
M5 x 0.8
1423
For detailed specifications, delivery and pricing, please contact SMC.
Series SYJ500/700Made to Order
Body Ported External Pilot
SYJ
VQZ
VP
VG
VP3�
007-SYJ.qxd 10.5.28 1:54 PM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1424
Series SYJ300/500/700Specific Product Precautions 1Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
� Non-locking push type [Standard]Press in the direction of the arrow
� Push-turn slotted locking type [Type D]
Locked position
� Push-turn locking lever type [Type E]
Locked position
PU
SH
LOC
K
Caution
Manual Override Operation
Warning
While pressing, turn in the direction of the arrow.If it is not turned, it can be operated the same way as the non-locking type.
When operating the locking type D with a screw driver, turn it gently using a watchmakers screw driver.[Torque: Less than 0.1 N.m]
While pressing, turn in the direction of the arrow.If it is not turned, it can be operated the same way as the non-locking type.
When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
Caution
When locking the manual override on the push-turn locking types (D, E), be sure to push it down before turning.Turning without first pushing it down can cause damage to the manual override and trouble such as air leakage, etc.
PU
SH
LOC
K
Solenoid valves with grommet and L/M type plug connector AC specifications have a built-in rectifier circuit in the pilot section to operate the DC coil.With 200, 220 VAC specification pilot valves, this built-in rectifier generates heat when energized. The surface may become hot depending on the energized condition; therefore, do not touch the solenoid valves.
Solenoid Valve for 200, 220 VAC Specifications
Warning
Pilot air is exhausted through the main valve body rather than directly to atmosphere.• Suitable for applications where exhausting the pilot valve to
atmosphere would be detrimental to the surrounding working environment.
• For use in extremely dirty environments where there is the possibility that dust could enter the pilot exhaust and damage the valve.
Ensure that the piping of exhaust air is not too restrictive.
Common Exhaust Type for Main and Pilot Valve
Caution
Bracket
For bracket attached styles of SYJ300, do not use it without bracket.
Caution
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1424
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1425
3. Attaching and detaching sockets with lead wires• Attaching Insert the sockets into the square holes of the connector (+, – indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.• DetachingTo detach a socket from a connector, pull out the lead wire while pressing the socket’s hook with a stick having a thin tip (approx. 1 mm). If the socket will be used again, first spread the hook outward.
How to Order Connector Assembly
For DC: SY100 30 4A
For 100 VAC: SY100 30 1A
Without lead wire: SY100 30 A
For other voltages of AC: SY100 30 3A
Lead wire lengthNil 6101520253050
300 mm600 mm
1000 mm1500 mm2000 mm2500 mm3000 mm5000 mm
For DCSYJ312-5LO-M3SY100-30-4A-20
For ACSYJ312-1LO-M3SY100-30-1A-20
For 200 VAC: SY100 30 2A
(with connector and 2 of sockets only)
How to Order Include the connector assembly part number together with the part number for the plug connector’s solenoid valve without connector.
EX.) In case of 2000 mm of lead wire
Connector
Lead wire
Socket
Hook
Lead wire Socket
Crimping areaCore wire crimping area
Hook Insulation
0.2 to 0.33 mm2 Max. cover diameter: ø1.7 mm
Core wire
2. Crimping of lead wires and sockets Strip 3.2 to 3.7 mm at the end of the lead wires, insert the ends of the core wires evenly into the sockets, and then crimp with a crimping tool. When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area.Use an exclusive crimping tool for crimping.(Contact SMC for special crimping tools.)
Socket
Hook
Lead wire
DC Polarity displayLever
Connector
Pin
GrooveCover
Pin
Groove
Cover
-+
1. Attaching and detaching connectors• To attach a connector, hold the lever and connector unit
between your fingers and insert straight onto the pins of the solenoid valve so that the lever’s pawl is pushed into the groove and locks.
• To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.
CautionHow to Use Plug Connector
Standard length is 300 mm, but the following lengths are also available.
CautionPlug Connector Lead Wire Length
Series SYJ300/500/700Specific Product Precautions 2Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1425
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DIN terminal has no polarity.
• Connect the standard type in accordance with the +, – polarity indication. (The non-polar type can be used with the connections made either way.)
• Since voltage specifications other than standard 24 and 12 VDC do not have diodes for polarity protection, be careful not to make errors in the polarity.
• Please use caution regarding the allowable voltage fluctu-ation because there is about a 1 volt drop for a valve with polarity protection. (For details, refer to the solenoid specifi-cations for the individual valve.)
• When wiring is done at the factory, positive (+) is red and negative (–) is black.
Operating Principle
(In the case of SYJ ��T, the electric wave form of energy saving type)
357
Applied voltage
StandardWith power
saving circuit
62 ms
24 V
0 V
0.4 W
0.1 W
0 W
� With power saving circuit Electric circuit (with power saving circuit)
1: Starting current 2: Holding current
2
Red (+)
Black (–)
LED
1
Power consumption is de-creased by 1/4 by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 62 ms at 24 VDC.)
With the above circuit, the current consumption when holding is re-duced to save energy. Please refer to the electric wave data to the right.• Please be careful not to reverse the
polarity, since a diode to prevent the reversed current is not provided for the power saving circuit.
• Please use caution regarding the allowable voltage fluctuation be-cause there is about a 0.5 volt drop due to the transistor. (For de-tails, refer to the solenoid specifications for the individual valve.)
Coil
Dio
de
Tim
er c
ircui
t
1 3
(Ground)
Type W
With light/surge voltage suppressor (�U)
� Non-polar typeWith surge voltage suppressor (�R)
With light/surge voltage suppressor (�Z)
� Standard type (with polarity)With light/surge voltage suppressor (�S)
4
3 1
Type WA
4
1(+)
3(-)
Diode to prevent reverse current
Diode to prevent reverse current
4 (Type WA)
3 (Type WA)
4 (Type WA)
3 (Type WA)
4 (Type WA)
3 (Type WA)
4 (Type WA)
3 (Type WA)
1(+)
3(-)
1(-)(+)
3(+)(-)
Varistor
1(-)(+)
3(+)(-)
Varistor
Solenoid valve side pin wiring diagram
1426
Surge Voltage Suppressor
<For DC> Grommet, L/M Plug Connector
� Standard type (with polarity)Surge voltage suppressor (�S)
Caution
Red (+)
Black (–)
Diode to prevent reverse current
With light/surge voltage suppressor (�Z)
Red (+)
Black (–)
Diode to prevent reverse current
� Non-polar typeWith surge voltage suppressor (�R)
With light/surge voltage suppressor (�U)
(–) (+)
(+) (–)
Varistor
(–) (+)
(+) (–)
Varistor
Coil
Coil
Coil
Coil
With surge voltage suppressor (DS)
With light/surge voltage suppressor (DZ)
Var
isto
rV
aris
tor
Coil
Coil
DIN Terminal
Coil
Coil Coil
Coil
• For the standard type, connect + to 1 and – to 3 for Type W according to polarity, while + to 4 and – to 3 for Type WA.
• Please be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for DC voltages other than 24 and 12 VDC.
• Please use caution regarding the allowable voltage fluctuation because there is about a 1 volt drop for a valve with polarity protection. (For details, refer to the solenoid specifications for the individual valve.)
• The WA-type valve cannot be grounded.
M8 Connector
Series SYJ300/500/700Specific Product Precautions 3Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1426
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet, L/M Plug Connector
With light (�Z)
DIN Terminal
With light (DZ)
<For AC>(There is no “S” type because the generation of surge voltage is prevented by a rectifier.)
Note) Surge voltage suppressor of varistor has residual voltage corresponding to the protective element and rated voltage; therefore, protect the controller side from the surge. The residual voltage of the diode is approximately 1 V.
Surge Voltage Suppressor
A type Y DIN connector is a DIN connector conforming to the 8-mm standard pitch between DIN terminals.
DIN Terminal Type Y
Solenoid Valve Mounting
· Since a type D DIN connector has a 9.4-mm pitch between DIN terminals, it is not interchangeable.
· Type D DIN connectors have the “N” indication at the end of rated voltage symbol. (For DIN connectors without lights, “N” is not indicated. Please refer to the name plate to distinguish.)
· Dimensions are the same as type D DIN connector.· When replacing only the pilot valve assembly, V115-�D is
interchangeable with V115-�Y. Do not replace V111 (G, H, L, M, W) to V115-�Y (DIN terminal), or vice versa.
4. Secure the cord by fastening the ground nut.
Changing the entry directionAfter separating the terminal block and housing, the cord entry can be changed by attaching the housing in the desired direction (4 directions at 90° intervals).∗ When equipped with a light, be careful not to damage the light
with the cord’s lead wires.
Compatible cable
Precautions Plug in and pull out the connector vertically without tilting to one side.
Cord O.D.: ø3.5 to ø7(Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306
Ground nuttightening torque1.65 to 2.5 N �m
Washer
Grommet (Rubber)
(Rating symbol)Refer to front matter 7.
Terminal screw(3 locations)Tightening torque0.2 to 0.25 N �m
Set screwTightening torque0.4 N �m
Housing
(Light mountinglocation)Terminal block
Notch
Mount it so that there is no slippage or deformation in gaskets, and tighten with the tightening torque as shown below.
Caution
ModelSYJ300SYJ500SYJ700
Thread sizeM1.7M2.5M3
Tightening torque0.12 N �m0.45 N �m0.8 N �m
1427
Caution
Caution
Coil
Var
isto
r
Var
isto
r
Coil
NL: Neon light
Connection 1. Loosen the holding screw and pull the connector out of the
solenoid valve terminal block.2. After removing the holding screw, insert a flat head screwdriv-
er, etc. into the notch on the bottom of the terminal block and pry it open, separating the terminal block and the housing.
3. Loosen the terminal screws (slotted screws) on the terminal block, insert the cores of the lead wires into the terminals ac-cording to the connection method, and fasten them securely with the terminal screws.
Caution
Caution
How to Use DIN Terminal
How to Use DIN Terminal
When making connections, take note that using other than the supported size (ø3.5 to ø7) heavy duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.
Caution
Series SYJ300/500/700Specific Product Precautions 4Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1427
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
<Type D>
Circuit Diagram with Light
Rated voltage24 VDC12 VDC100 VAC200 VAC110 VAC220 VAC
Voltage symbol24 V12 V
100 V200 V110 V220 V
Part no.SY100-61-3-05SY100-61-3-06SY100-61-2-01SY100-61-2-02SY100-61-2-03SY100-61-2-04
Without light SY100-61-1With light
<Type Y>
Rated voltageDC24 VDC12 V100 VAC200 VAC
110 VAC(115 VAC)220 VAC(230 VAC)
Voltage symbol24 VN12 VN
100 VN200 VN110 VN220 VN
Part no.SY100-82-3-05SY100-82-3-06SY100-82-2-01SY100-82-2-02SY100-82-2-03SY100-82-2-04
Without light SY100-82-1With light
AC circuit
NL : Neon lightR : Resister
LED : Light emitting diodeR : Resister
DC circuit
Connector assembly with dust proof protective cover.• Effective to prevention of short circuit failure due to the entry of
foreign matter into the connector.• Chloroprene rubber for electrical use, which provides outstand-
ing weather resistance and electrical insulation, is used for the cover material. However, do not allow contact with cutting oil, etc.
• Simple and unencumbered appearance by adopting round-shaped cord.
CautionConnector Assembly with Cover
Nil
101520253050
300 mm
1000 mm6 600 mm
1500 mm2000 mm2500 mm3000 mm5000 mm
Lead wire length
SY100-68-AHow to Order
Connector Assembly with Cover: Dimensions
Red Black
Gray
(14.5) L
(40)
(10)(8)
(8)
(6.9
)
(ø4.
1)
Symbol for connector assembly with cover
How to Order Enter the part number for a plug connector solenoid valve without connector together with the part number for a connector assem-bly with cover.Ex. 1) Lead wire length of 2000 mm
SYJ312-5LOZ-M3 SY100-68-A-20
Ex. 2) Lead wire length of 300 mm (standard) SYJ312-5LPZ-M3
∗ In this case, the part number for the connector assembly with cover is not required.
1428
CautionDIN Connector Part No.
Series SYJ300/500/700Specific Product Precautions 5Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1428
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
22 33.9
14
2. To order connector cable only
357
Electrical entry W1, WA1: Cable length 300 mm W2, WA2: Cable length 500 mmW3, WA3: Cable length 1000 mmW4, WA4: Cable length 2000 mm W7, WA7: Cable length 5000 mm
SYJ
13
4
33.9
ø9
L 35 10
Note) Connector cable should be mounted in the correct direction. Make sure that the arrow symbol on the connector is facing the triangle symbol on the valve when using SMC connector cable (V100-49-1-�). Be careful not to squeeze it in the wrong direction, as problems such as pin damage may occur.
M8 Connector
1. M8 connector types have an IP65 (enclosure) rating, offering protection from dust and water. However please note: these products are not intended for use in water.Select a SMC connector cable (V100-49-1-�) or a FA sensor type connector, with M8 threaded 3 pin specifications conforming to Nippon Electric Control Equipment Association Standard, NECA4202 (IEC60947-5-2). Make sure the connector O.D. is 10.5 mm or less when used with the Series SYJ300 manifold. If more than 10.5 mm, it cannot be mounted due to the size.
2. Do not use a tool to mount the connector, as this may cause damage. Only tighten by hand. (0.4 to 0.6 N�m)
3. The excessive stress on the cable connector will not be able to satisfy the IP65 rating. Please use caution and do not apply a stress of 30 N or greater.
Failure to meet IP65 performance may result if using alternative connectors than those shown above, or when insufficiently tight-ened.
Caution
Caution
• Connector cable mounting
Arrow mark
Triangle mark
� Connector cable� Connector cable for M8 can be ordered as follows:
1. To order solenoid valve and connector cable at the same time. (Connector cable will be included in the shipment of the solenoid valve.)
How to Order
Ex. 1) Cable length: 300 mmSYJ312-5W1ZE-M3
Symbol for electrical entry
Connector dimensions
Brown: 1 Blue: 3
Black: 4
Cable length (L)
500 mm1000 mm2000 mm5000 mm
Part no.
V100-49-1-2300 mm V100-49-1-1
V100-49-1-3V100-49-1-4V100-49-1-7
1429
Series SYJ300/500/700Specific Product Precautions 6Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
SYJ
VQZ
VP
VG
VP3�
P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1429
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
A B+-
A B+-
1430
Pilot valves in this series are improved to provide excellent energy saving results. However following this improvement, these new valves are no longer compatible with the conventional pilot valve used at the interface. Consult with SMC when you need to exchange these pilot valves, in the case of manual override (marked in orange) of the adapter plate.
Replacement of Pilot Valve
Caution
New type
Conventional type
(Orange)
Manual override
(Blue)Manual override
Interface
Pilot valve (V111) Adapter plate
Interface
Pilot valve (SY114) Adapter plate
Series SYJ300/500/700Specific Product Precautions 7Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.