OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-0
Contents
Safety Precautions..........................................................................Page3
Routine Maintenance......................................................................Page11
Common Maintenance Operations...................................................Page26
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
2/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-1
After the course, the trainees should list the routine maintenance items, and be clear
about the purpose of those items. This is the basics of OptiX RTN 910/950
maintenance, and do them well can prevent equipment from some faults.
Besides listing the routine maintenance items, trainees also must grasp the correct
maintenance operations of OptiX RTN 910/950, that is important in the maintenance
and troubleshooting.
Through the checking of routine maintenance items of OptiX RTN 910/950, operators
also need to judge some of the common faults by using some common method like
observe indicator, calling orderwire, etc.
Reference is RTN 910 Maintenance Guide and RTN 950 Maintenance Guide
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
3/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-2
There are 3 chapters in this course. Chapter 1 describes parts of the precautions to
be taken during installing, operating, and maintaining the equipment.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
4/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-3
Read and follow the safety precautions before installing, operating, and maintaining
the equipment.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
5/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-4
The grounding requirements are applicable to the equipment that needs
to be grounded.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
6/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-5
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
7/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-6
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
8/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-7
Before turning the toggle lever switch (ODU power switch on the IF board), please
pull it out slightly.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
9/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-8
Before inserting the IF jumper into the IDU or removing the IF jumper or IF cable from
the IDU, the ODU must be powered off .
In the case of an RG-8U or a 1/2-inch IF cable, the IF cable is connected to the IDU
through an IF jumper. In the case of a 5D IF cable, the IF cable is directly connected
to the IDU.
Do not remove or insert the IF jumper or IF cable when the ODU is powered on.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
10/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-9
Before inserting the IF cable into the IDU or removing the IF cable from the IDU, the
ODU must be powered off.
Do not remove or insert the IF cable when the ODU is powered on.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
11/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-10
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
12/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-11
Routine maintenance items are classified into three categories: routine maintenance
items carried out through the NMS, field maintenance items for indoor equipment, and
field maintenance items for outdoor equipment.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
13/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-12
The operator on site can judge the service is normal or not by observing the SRV
indicator. For example, if the SRV indicator lit red, usually is caused by the receiving
power problem and the service in this board is lost or switched to other board. Youmay take out the patch cord or the cable to check.
Note:
The STAT indicator on some boards may not light when the equipment is
powered on due to data configuration.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
14/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-13
If bit errors cross the threshold, it needs to check the link indicator on IF board and
ODU receiving power via NMS for reference, also needs to exclude the weather
condition.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
15/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-14
If the voice in the conversation through orderwire call is not clear and with noise, it
needs to check the connection between phone and IDU first, then observe the
indicators on IF board to check status of microwave link for reference.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
16/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-15
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
17/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-16
Checking the equipment room periodically not only ensures that the equipment can
operate normally in appropriate temperature and humidity conditions, but also
reduces the fault rate and increases the service life of the equipment.
Procedure
Record the reading of the thermometer in the equipment room. The normal
temperature should be between5C and +55C.
Record the reading of the humidity meter in the equipment room.The normal
humidity should be between 5% and 95%.
Check whether the equipment room meets the disaster protection
requirements. Ensure the following points:
There are portable foam fire extinguishers in the equipment room. The
fire extinguishers should be in their service life.
There is no rain leakage or water penetration in the equipment room.
There are no mice or insects in the equipment room.
Clean the equipment room. Ensure that there is no dust on the cabinets, on
the equipment
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
18/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-17
In the OptiX RTN 910/950 system, out door parts are composed of the ODU, hybrid
coupler, antenna and IF cable, so the field maintenance items for outdoor equipment
are mainly for them.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
19/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-18
Procedure
Ensure that the ODU is located within the protected area of the lightning
arrester. In plain areas, the lightning arrester protects the areas within an
angle of 45under it. In mountainous areas and the areas where lightning
frequently occurs, the lightning arrester protects the area within an angle of
30 under it.
Ensure that the ODU is properly fixed on the antenna.
Ensure that the ODU is not damaged.
Ensure that the interface between the ODU and the hybrid coupler/antenna is
waterproof.
Ensure that the protection grounding cable of the ODU is firmly and reliably
grounded.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
20/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-19
Procedure:
Ensure that the hybrid coupler is located within the protected area of the
lightning arrester. In plain areas, the lightning arrester protects the areas within
an angle of 45 under it. In mountainous areas and the areas where lightning
frequently occurs, the lightning arrester protects the area within an angle of
30under it.
Ensure that the hybrid coupler is properly fixed on the antenna.
Ensure that the hybrid coupler is not damaged.
Ensure that the interface between the hybrid coupler and the antenna is
waterproof.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
21/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-20
Procedure
Ensure that the antenna is located within the protected area of the lightning
arrester. In plain areas, the lightning arrester protects the areas within an
angle of 45under it. In mountainous areas and the areas where lightning
frequently occurs, the lightning arrester protects the area within an angle of
30 under it.
Ensure that the antenna is reliably fixed on the pole.
Ensure that the antenna radome is not damaged.
Ensure that there is no accumulated water in the antenna.
Ensure that the fastening bolts are fastened. Ensure that the azimuth angle
and the elevation angle of the antenna meet the design requirements
In the case of separate mounting, ensure that the installation parts areinstalled firmly and that the connectors are fastened.
Check and ensure that the interface of the feed boom is sealed and
waterproofed properly.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
22/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-21
Procedure:
Check the appearance of the IF cable.
The IF cable must not be bent or twisted.
There must be no bare copper wire.
The bending radius of the IF cable must be larger than 30 cm.
Check the connectors of the IF cable.
The connectors of the IF cable must be reliably connected to the ODU.
The connectors of the IF cable must be waterproof.
Check the grounding of the IF cable.
The grounding clip must be waterproof.
The grounding cable must be routed from top downwards. The angle
between the grounding cable and the IF cable must not be more than
15 degrees.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
23/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-22
Checking the NE Status
By checking the NE status periodically, you can detect the NE faults in time.
Browsing the Current Alarms
A current alarm is an alarm that is not cleared. Browsing the current alarms
periodically helps in detecting and rectifying faults in time.
Browsing the History Alarms
A history alarm is an alarm that is cleared. Browsing and storing the history
alarm information periodically helps in locating and rectifying faults.
Browsing the Abnormal Events
This topic describes how to browse the abnormal events. An abnormal event
is an abnormality that arises in the system at a particular time and not an
abnormality that persists for a long time. Browsing the abnormal eventsperiodically helps in detecting equipment faults in time.
Browsing Current Performance Events
Periodically browsing the performance events helps you to check the long-
term running status of the equipment. Hence, the latent hazards can be
detected and cleared in time. The counter of current performance events
measures all the performance events that arise between the start time of the
monitoring period and the current time.
Browsing the History Performance Events
Periodically browsing and storing the history performance events helps in
locating faults.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
24/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-23
Browsing the History Transmit Power and Receive Power
By browsing the history transmit power and receive power periodically, you
can know the change trend of the history transmit power and receive power,
which provides references for troubleshooting the radio link.
Testing the IF 1+1 Switching
Testing the IF 1+1 switching periodically helps in checking whether switching
can be performed on the equipment normally.
Testing the IF N+1 Switching
Testing the IF N+1 switching periodically helps in checking whether switching
can be performed on the equipment normally.
Applies only to the equipment that is configured in 1+1 protection mode.
During the 1+1 protection switching (< 500 ms), the protected services are interrupted.Hence, it is recommended that you perform the 1+1 protection switching when the
traffic is light.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
25/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-24
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
26/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-25
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
27/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-26
Hardware loopback is classified into optical cable loopback, PDH cable loopback, and
Ethernet port loopback.
Optical cable loopback indicates that the receive and transmit optical fibers are
connected through a fiber jumper on the ODF. In certain occasions, an optical
attenuator is added based on the actual situation, to prevent the optical board
from being damaged by the excessive receive optical power.
PDH cable loopback indicates that the receive and transmit PDH cables are
connected through a short-circuiting cable or connector on the DDF.
Ethernet port loopback indicates that the receive and transmit service signals
on one Ethernet port are looped back through a special loopback Ethernet
cable.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
28/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-27
During following the above 3 steps to plug out the board, we must operate slowing
and make sure operation not affect the other running boards.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
29/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-28
During following the above 3 steps to plug in the board, we must operate slowing and
make sure there is no any blocking in the slot. And in the step 1 above, it is not
allowed to push the board along the guiding rail by force if when there is someblocking inside.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
30/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-29
When the IF board is replaced, the unprotected services on the board are interrupted.
Prerequisite
You must know the impact of board replacement. You must know the specific position of the board to be replaced.
You must know the service protection and protection channels of the board to bereplaced.
The spare board must be available, and the version and type of the spare board mustbe the same as the version and type of the board to be replaced. You can query theboard manufacturing information to obtain the version of the board to be replaced.
Optional
If the services on the board are configured with SNCP, ensure that the services arealready switched to the protection channel.
1. Query the SNCP protection group.
2. If the port on the board functions as the current working channel, the current
protection channel is not on the board, and the state of the current protectionchannel is normal or SD,perform the forced switching.
If the services on the radio link are configured with 1+1 protection, switch the service tothe protection IF board.
1. Query the IF 1+1 protection group.
2. If the board functions as the current working board, and the state of thecurrent protection board is normal or SD, perform the forced switching
If the services on the radio link are configured with N+1 protection, ensure that theservices are already switched to the protection IF board.
1. Query the IF N+1 protection group.
2. If the board functions as the current working board, and the state of the
current protection board is normal or SD, perform the forced switching. If the IF board is configured with the XPIC function, see Setting the State of an ODU
Transmitter and mute the ODU at the opposite end.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
31/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-30
Optional:
If the forced SNCP switching has been performed for the services, release the
forced switching.
If the forced protection switching has been performed for the radio link, release
the forced switching.
If the IF board is configured with the XPIC function, see Setting the State of an
ODU Transmitter and unmute the ODU at the opposite end.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
32/46
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
33/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-32
When the PDH interface board is replaced, the services on the board are interrupted.
Prerequisite
You must know the impact of board replacement.
You must know the specific position of the board to be replaced.
You must know the service protection and protection channels of the board to
be replaced.
The spare board must be made available, and the version and type of the
spare board must be the same as those of the board to be replaced. You can
query the board manufacturing information to obtain the version of the board
to be replaced.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
34/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-33
When the Ethernet interface board is replaced, the unprotected services on the board
are interrupted.
Prerequisite
You must know the impact of board replacement.
You must know the specific position of the board to be replaced.
You must know the service protection and protection channels of the board to
be replaced.
The spare board must be made available, and the version and type of the
spare board must be the same as those of the board to be replaced. You can
query the board manufacturing information to obtain the version of the board
to be replaced.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
35/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-34
Prerequisite
You must be aware of the impact of board replacement.
You must know the specific position of the board to be replaced.
You must know the service protection and protection channels of the board to
be replaced.
The spare board must be made available, and the version and type of the
spare board must be the same as those of the board to be replaced. You can
query the board manufacturing information to learn about the version of the
board to be replaced.
Impact on System
If no protection board is available, the replacement of the system control,
switching, and timing board results in service interruption. After the NE starts up normally, the STAT indicator on the board is green, and the
PROG indicator on the board is off.
In the process of restoring the NE database, the PROG indicator on the board blinks
in green.
If the PROG indicator stops blinking and is on and green for 10 seconds, it indicates
that the deployment script is run successfully. The PROG indicator is then normally
on and green.
If the PROG indicator stops blinking and is on and red for 10 seconds, it indicates that
the deployment script is run unsuccessfully. The PROG indicator is then normally on
and green. In this case, contact Huawei technical support engineers for rectifying thefault.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
36/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-35
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
37/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-36
Install the ODU
a. Remove the protective cap on the antenna interface of the ODU. Apply an
appropriate amount of lubricant to the gasket of the feeder on the antenna,
coupler, or ODU adapter.
CAUTION:
Do not dispense the lubricant on the front panel of the feeder.
Otherwise, it may affect the signal transmission.
b. Keep the direction indicated by the polarization arrow on the ODU consistent
with the polarization direction of the antenna or hybrid coupler. (In the case
of vertical polarization, keep the polarization arrow vertical. In the case of
horizontal polarization, keep the polarization arrow horizontal). Slowly fit the
antenna interface of the ODU into the feeder until the four latches on theODU engage with the hooks on the antenna.
c. Lock the four latches in a diagonal order.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
38/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-37
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
39/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-38
Procedure (Querying the Board Information Report)
Choose Inventory > Physical Inventory > Board from the Main Menu.
In Physical Inventory, click the Board List tab.
Click Filter.In Set Board Filter Criteria window, set the board attributes that
need to be queried. Click OK.
Optional: Click Save As. Then, you can save and archive the board
information as a text file.
Procedure (Querying the Board Manufacturing Information Report)
Choose Inventory > Project Document > Board Manufacture Information
from the Main Menu.
In Board Manufacture Information, click the Board Manufacture
Information tab.
Select one or multiple NEs from the left pane, and click .
Optional: Click Save As. Then, you can save and archive the board
manufacturing information as a text file.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
40/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-39
Setting Loopback for the SDH Optical Interface Board
The optical interface board supports the optical interface inloop and the VC-4
path outloop
Setting Loopback for the Tributary Board
The tributary board supports the tributary inloop and outloop
Setting Loopback for the Ethernet Interface Board
The Ethernet interface board supports the Ethernet port inloop (at the MAC
layer and PHY layer)
Setting Loopback for the IF Board
Loopbacks on the IF board are classified into IF port loopback, composite port
loopback, VC-4 path loopback, and IFUP port MSC loopback. The IF1 board
supports the IF port inloop, IF port outloop, and VC-4 path inloop. The IFU2board supports the IF port outloop, composite portinloop, composite port
outloop, and IFUP port MAC inloop. The IFX2 board supports thecomposite
port inloop, composite port outloop, and IFUP port MAC inloop.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
41/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-40
Cold reset causes service interruption because it is similar to the procedure of
removing and inserting a board.
Procedure
Step 1 In NE Panel, right-click the board where the warm reset needs to be
performed.
Step 2 Choose Warm/Cold Reset from the shortcut menu. Then, the
Warning dialog box is displayed.
Step 3 Click OK.
Step 4 Close the dialog box that is displayed.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
42/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-41
Caution
During the PRBS test, the services on the tested path are interrupted.
The PRBS test can be performed only on one path and in one direction.
Procedure
Set the loopback at the proper location. For details.
Select the E1 interface board from the Object Tree.
Choose Configuration > PRBS Test from the Function Tree.
Select the port to be tested.
Set Duration and Measured in Time.
The PRBS test supports three time units: one second, 10 minutes, andone hour.
A maximum of 255 test cycles is permissible for the PRBS test.
Optional: Select Accumulating Mode.
Click Start to Test.Then, a prompt dialog box is displayed.
Click OK.
When Process is displayed as 100%, click Query to check the test result.
Note
The result of a PRBS test can be normal, error, or invalid.
Invalid: indicates that no bit is received. The curve should be yellow.
Normal: indicates that the path is working properly. The number of PRBSsshould be zero, and the curve should be green.
Error: indicates that the path has errors. The number of total PRBS should belarger than zero, and the curve should be red.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
43/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-42
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
44/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-43
Caution
During the PRBS test, the services on the tested path are interrupted.
The PRBS test can be performed only on one path and in one direction.
Before you perform the PRBS test for the protection IF board of a 1+1HSB/FD/SD protection group, you must switch the protection IF board to theworking state manually.
The protection IF board does not support the PRBS test. To test the protectionradio link, you need to power off the main ODU and perform the PRBS test onthe main IF board. In this case, the PRBS signals are sent out of the protectionIF board through the protection bus, thus implementing the PRBS test of theradio link.
Procedure
Perform an outloop on the IF board. For details, see 7.3.4 Setting Loopbackfor the IF Board.
Select the IF board from the Object Tree.
Choose Configuration > PRBS Test from the Function Tree.
Select the port to be tested.
Set Duration and Measured in Time.
The time unit of the PRBS test can be one second, 10 minutes, or onehour.
A maximum of 255 test cycles is permissible for the PRBS test.
Optional: Select Accumulating Mode.
Click Start to Test. Then, a prompt dialog box is displayed.
Click OK.
When Process is displayed as 100%, click Query to check the test result.
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
45/46
OptiX RTN 910/950 Routine Maintenance
Confidential Information of Huawei. No Spreading Without
Permission
P-44
-
8/13/2019 3 - OTF202202 OptiX RTN 910950 V100R002 Routine Maintenance ISSUE1.00
46/46
OptiX RTN 910/950 Routine Maintenance P-45