3-ф FULLY CONTROLLED BRIDGE CONVERTER

31

Transcript of 3-ф FULLY CONTROLLED BRIDGE CONVERTER

Page 1: 3-ф FULLY CONTROLLED BRIDGE CONVERTER
Page 2: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

CIRCUIT

Page 3: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

DESCRIPTIONThe three phase full converter is extensively

used in industrial power applications up to about 120kW output power level.

All the six thyristors are controlled switches which are turned on at a appropriate times by applying suitable gate trigger signals.

The frequency of output ripple voltage is 6fs

Page 4: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS 6

3

6

tot

Page 5: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS6

5

6

3 tot

Page 6: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS 6

7

6

5 tot

Page 7: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS 6

9

6

7 tot

Page 8: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS 6

11

6

9 tot

Page 9: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS 2

13

6

11 tot

Page 10: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

OPERATIONSINO

TIME OF CONDUCTION

CONDUCTING

THYRISTORS

OUTPUT VOLTAGE

01 α + 30 TO α + 90 T6 & T1 VAB

02α + 90 TO α +

150T1 & T2 VCA

03α + 150 TO α +

210T2 & T3 VBC

04α + 210 TO α +

270T3 & T4 VAB

05α + 270 TO α +

330T4 & T5 VCA

06α + 330 TO α +

390T5 & T6 VBC

Page 11: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

OUTPUT WAVEFORMS

Page 12: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS

Where Vm is the peak phase voltage of a star (Y) is connected source.

Page 13: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

ANALYSIS

Page 14: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

Expression for average output voltage

Page 15: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

Expression for RMS value of voltage

Page 16: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

Effect of source inductanceOverlap period Overlap angle (μ) or commutation anglePractically supply voltage is neglected.If source is of high resistive, then average

output voltage decreases by average drop in source resistance.

Page 17: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

DUAL CONVERTERIf two single phase full converters are

connected in parallel and in opposite direction (connected in back to back) across a common load four quadrant operation is possible. Such a converter is called as a dual converter.

We can thus have bi-directional load current and bi-directional dc output voltage. The magnitude of output dc load voltage and the dc load current can be controlled by varying the trigger angles of the converters α1 and α2 respectively.

Page 18: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

4-Quadrant operation

Page 19: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

1- dual converter

Page 20: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

Modes of operation of DUAL converterTwo Modes

Non circulating current mode of operation (circulating current free mode of operation).

Circulating current mode of operation.

Page 21: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

NONCIRCULATING CURRENT MODEOnly one converter is switched on at a time.For 1st quadrant operation, α1 < 900 , power

is positive.For 4th quadrant operation, α1 > 900 , power

is negative.For 2nd quadrant operation, α2 < 900 , power

is positive.For 3rd quadrant operation, α2 > 900 , power

is negative.

Page 22: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

NONCIRCULATING CURRENT MODEAdvantages:

no circulating current flowing between the two converters

no need of the series current limiting inductors between the outputs of the two converters

The current rating of thyristors is low in this mode

Page 23: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

NONCIRCULATING CURRENT MODEDisadvantages:

the load current tends to become discontinuous and the transfer characteristic becomes non linear.

The control circuit becomes complex and the output response is sluggish as the load current reversal takes some time due to the time delay between the switching off of one converter and the switching on of the other converter.

Whenever a fast and frequent reversal of the load current is required, the dual converter is operated in the circulating current mode.

Page 24: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

Wave forms

Page 25: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

CIRCULATING CURRENT MODEIn this mode of operation both the converters

1 and 2 are switched on and operated simultaneously and both the converters are in a state of conduction.

If converter 1 is operated as a controlled rectifier by adjusting the trigger angle between 0 to 900 the second converter 2 is operated as a line commutated inverter by increasing its trigger angle above 900.

Page 26: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

Relation between α1 and α2The trigger angles and are adjusted such

that they produce the same average dc output voltage across the load terminals.

Vdc1 = -Vdc2 then α2 = п – α1

Page 27: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

CIRCULATING CURRENT MODEIn the circulating current mode a current

builds up between the two converters even when the load current falls to zero. In order to limit the circulating current flowing between the two converters, we have to include current limiting reactors in series between the output terminals of the two converters.

The disadvantage of the circulating current mode of operation is that a current flows continuously in the dual converter circuit even at times when the load current is zero.

Page 28: 3-ф FULLY CONTROLLED BRIDGE CONVERTER

3-phase dual converter

Page 29: 3-ф FULLY CONTROLLED BRIDGE CONVERTER
Page 30: 3-ф FULLY CONTROLLED BRIDGE CONVERTER
Page 31: 3-ф FULLY CONTROLLED BRIDGE CONVERTER