3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of...

19
Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Transcript of 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of...

Page 1: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills

Quinn Danyluk, MSc, CIH

Page 2: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

1. Background2. Methodology & Products Evaluated3. Results of Effectiveness on Simulated Spills

Agenda

Page 3: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

1. Background

Page 4: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

1. Background

Use in Healthcare

Formaldehyde:MW: 30.03Vapour Pressure: 1.3 mm Hg (@ 20oC)Vapour Density: 1.08 (air = 1)

O

HH

Formalin is a methanol-stabilized water solution which can contain varying levels of formaldehydeCommonly 10% or 37% formaldehyde solutions

Page 5: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

1. Background

Use in Healthcare

In healthcare, generally used to fix tissueFound in:

Anatomical Pathology / HistologyMorgueOperating Room

Page 6: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

1. Background

Potential Health Effects

SensitizerCarcinogen

ACGIH A2, Suspected Human CarcinogenIARC Group 1, Confirmed Human Carcinogen

Eye and URT Irritant0.1 – 25 ppm

ACGIH Ceiling Limit of 0.3 ppm

Page 7: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

2. Methodology & Products Evaluated

Page 8: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

2. Methodology & Products Evaluated

Products Evaluated

Vytac Polyform

Fan Pads - Large Pig Mats Fan Pads - Small

Page 9: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Quantitative Assessment

Required:Dedicated area to allow for multiple trials under set conditionsSegregated, negative pressure roomEnvironmental conditions approximating normal conditions

2. Methodology & Products Evaluated

Page 10: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH
Page 11: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

3. Results of Effectiveness on Simulated Spills

Page 12: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Formalin Spill Cleanup Products: 100 mL Spill

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 5 10 15 20 25 30

Time (min)

Con

cent

ratio

n (p

pm)

Measured Average

Page 13: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Formalin Spill Cleanup Products: 100 mL Spill

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 5 10 15 20 25 30

Time (min)

Con

cent

ratio

n (p

pm)

Measured Average

Large Fan Pads

Page 14: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Formalin Spill Cleanup Products: 100 mL Spill

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 5 10 15 20 25 30

Time (min)

Con

cent

ratio

n (p

pm)

Measured Average

Large Fan Pads

Pig Mat

Page 15: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Formalin Spill Cleanup Products: 100 mL Spill

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 5 10 15 20 25 30

Time (min)

Con

cent

ratio

n (p

pm)

Measured AverageLarge Fan PadsPig MatSmall Fan Pad

Page 16: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Formalin Spill Cleanup Products: 100 mL Spill

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 5 10 15 20 25 30

Time (min)

Con

cent

ratio

n (p

pm)

Measured AverageLarge Fan PadsPig MatSmall Fan PadVytac

Page 17: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Formalin Spill Cleanup Products: 100 mL Spill

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 5 10 15 20 25 30

Time (min)

Con

cent

ratio

n (p

pm)

Measured AverageLarge Fan PadsPig MatSmall Fan PadVytacPolyform

Page 18: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Acknowledgements

WorkSafeBC Research Secretariat Fraser Health Workplace Health Management Team and Prevention TeamSurrey Memorial Hospital Sterile Processing DepartmentRoyal Columbian Hospital Laboratory DepartmentPrecillia (Percy) Chua, MSc(A)UBC SOEHOccupational Health & Safety Agency for Healthcare in BC

Page 19: 3 Evaluation of the Effectiveness of Select Spill Control ... · Evaluation of the Effectiveness of Select Spill Control Products for Formalin Spills Quinn Danyluk, MSc, CIH

Questions?