2
WARRANTY: This product has a warranty of period of 5 years from the date of purchase. The warranty is invalid in the case of improper use, installation, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National Electric Code. Should this product fail during the warranty period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice. PRODUCT SIZE - AR-DL2240 PRODUCT SIZE - AR-DL2256 POLAR CURVE AR-DL2240 AR-DL2256 SECTION #4: RECESSED CAN HOUSINGS The Aurora LED Retrofit Trims are designed to fit with most recessed CANs. The AR-DL2240 will fit most 4 inch CANs and the AR-DL2256 is designed to fit most 5 or 6 inch CANs. CANs specifically tested to ensure proper fit are as follows: Min: 5.23" Min:5.51" 3.35" 7.20" Min: 4" Min: 5.6" 2.96" Φ5.32" 0 30 60 90 120 150 -/+180 -150 -120 -90 -60 -30 UNIT:cd C0/180,89.8deg UNIT:cd C90/270,91.4deg AVERAGE BEAM ANGLE(50%):90.6 DEG 0 70 140 210 280 350 0 30 60 90 120 150 -/+180 -150 -120 -90 -60 -30 UNIT:cd C0/180, 47.1,45.7 UNIT:cd C90/270, 47.2,45.0 AVERAGE BEAM ANGLE(50%):92.5 DEG 0 120 240 360 480 600 AR-DL2256 DMF DH6ICAQ Elite B6IC Juno IC21 June IC20 Juno IC22 Halo H5RICAT Halo H7ICAT Halo H27ICAT Halo H5T Halo H750ICAT Halo H272ICAT Halo H7ICT Halo H27T Halo H25ICAT Lithonia L7XPHCR6 Lithonia LC6 Philips PR75ASIC AR-DL2240 Commercial Electric HBR2000R (H10) Commercial Electric HBR2000B (H9) Elite B4IC Halo H99ICAT Halo H99TAT Halo H99RT Juno TC1 Juno IC1 Lithonia L3R Lithonia L3U Aurora Lighting Inc., 12035 34th St N, Suite 2, St Petersburg, FL 33716, USA Document Version IS_AR-DL22xxV2 Website: www.auroralighting.com Email: [email protected] LED RETROFIT TRIM PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE IMPORTANT INSTALLATION INFORMATION WARNING RISK OF ELECTRIC SHOCK Disconnect power before performing installation or maintenance. Verify that supply voltage is correct by comparing it with the luminaire label information. Make all electrical grounded connections in accordance with the latest edition of the National Electric Code (NEC) and applicable local code requirements. If the supply wire is damaged, it must be replaced by the manufacturer or their service agent or a similar qualified person in order to avoid a hazard. All wiring connections should be capped with UL approved wire connectors. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved. Connect fixture to a 120 volt,60 Hz power source. Any other connection voids the warranty. WARNING CAUTION Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. If electrical appliances are disposed of in landfill or dumps, hazardous substances can be damaging to health and well-being. Contact your local government for information regarding the collection system available. This device is not intended for use with emergency exit fixtures or emergency exit lights. To reduce the risk of electrical shock, do not remove cover and caps, fitting must be grounded. No user-serviceable parts inside. Do not use when enclosure is broken. To prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or other sharp objects. Indoor use only. WARNING RISK OF BURNS Follow all manufacturer’s warnings and recommendations for the luminarie installation methods, replacement and recycling. Luminaire not suitable for covering with thermally insulating material unless installed in an IC Rated Housing. Please ensure there is no thermal insulation within 200mm of the luminaire when not installed in an IC Rated Housing. WARNING RISK OF FIRE Keep any combustible and other materials that can burn away from the luminaire. Incorrect installation may result in electrical shock or a risk of a fire. MINIMUM 90°C SUPPLY CONNECTIONS For Models: AR-DL2240/27, AR-DL2240/30, AR-DL2240/40, AR-DL2240/50 AR-DL2256/27, AR-DL2256/30, AR-DL2256/40, AR-DL2256/50 1 4

Transcript of 295*195mm -...

Page 1: 295*195mm - db.aurora.co.s3.amazonaws.comdb.aurora.co.s3.amazonaws.com/FamilyData/23334/13426/FileUpload/... · WARRANTY: This product has a warranty of period of 5 years from the

WARRANTY: This product has a warranty of period of 5 years from the date of purchase. The warranty is invalid in the case of improper use, installation, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National Electric Code. Should this product fail during the warranty period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.

PRODUCT SIZE - AR-DL2240

PRODUCT SIZE - AR-DL2256

POLAR CURVE

AR-DL2240 AR-DL2256

SECTION #4: RECESSED CAN HOUSINGSThe Aurora LED Retrofit Trims are designed to fit with most recessed CANs. The AR-DL2240 will fit most 4 inch CANs and the AR-DL2256 is designed to fit most 5 or 6 inch CANs. CANs specifically tested to ensure proper fit are as follows:

295*195mm

B

18AWGSOLID

Min: 5.23"

Min:5.51"

3.35"

7.20"

3

……

295*195mm

B

18AWGSOLID

Min: 4"

Min: 5.6"

2.96"

Φ5.32"

www......com

AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. L’INSTALLATION DE CE NÉCESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET DES RISQUES ASSOCIÉS. TOUTE PERSONNE QUI N’EST PAS QUALIFIÉE NE DOIT FAIRE AUCUNE TENTATIVE D’INSTALLATION ET DOIT CONTACTER UNE PERSONNE QUALIFIÉE.

AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. N’INSTALLER CE NÉCESSAIRE QUE DANS LES LUMINAIRES DONT LES CARACTÉRISTIQUES DE CONSTRUCTION ET LES DIMENSIONS SONT CONFORME À CELLES ILLUSTRÉES DANS LES PHOTOS ET/OU LES DESSINS ET. IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OUVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE COMPOSANTS ÉLECTRIQUES AU COURS DE L’INSTALLATION DU NÉCESSAIRE.

AVERTISSEMENT – AFIN DE PRÉVENIR L’ENDOMMAGEMENT OU L’ABRASION DES CÂBLES, ÉVITER TOUT CONTACT ENTRE CES DERNIERS ET LE BORD D’UN OBJET TRANCHANT TEL QU’UNE TÔLE.

AVERTISSEMENT – NE CONVIENT PAS AUX SORTIES DE SECOURS.

LOGO

BEST TEST SERVICE SHENZHEN CO.,LTDPage 1 Of 14

LUMINAIRE PHOTOMETRIC TEST REPORT

NAME:

SPEC.:

MFR.: Leedarson

TYPE:DL-N2ER-D-600-XXXX

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

PROTECTION ANGLE:

Test:U:120.0V I:0.0709A P:8.337W PF:0.9797 Lamp Flux:667.351x1 lm

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cdC0/180,89.8deg

UNIT:cd

C90/270,91.4deg

AVERAGE BEAM ANGLE(50%):90.6 DEG

0

70

140

210

280

350

LUMINOUS INTENSITY DISTRIBUTION DIAGRAMPLANAR ISOLUX DIAGRAM(UNIT:lx)

MH=1m

S(m)0

1

2

3

90

80

70

60

50

40

30

2010 0

C(DEG)

260230190160130

97.032.016.09.703.20

DATA OF LAMPPHOTOMETRIC DATAEff: 80.05 lm/W

MODEL

NOMINAL POWER(W)

RATED VOLTAGE(V)

NOMINAL FLUX(lm)

LAMPS INSIDE

TEST VOLTAGE(V)

Imax(cd)

LOR(%)

TOTAL FLUX(lm)

CIE CLASS

up(%)

down(%)

S/MH(C0/180)

S/MH(C90/270)

UP,DN(C0-180)

UP,DN(C180-360)

CIBSE SHR NOM

CIBSE SHR MAX

DL-N2ER-D-600-XXXX

9

120.0

667.351

1

120.0

322.8

100.0

667.35

DIRECT

0.0

100.0

1.16

1.11

0.0,52.3

0.0,47.7

1.25

1.25

C Range: 0 - 360DEGC Interval: 22.5DEG

Range: 0 - 180DEG Interval: 1.0DEG

Test Speed: HIGHTest System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEGHumidity:67.1%

Test Distance:2.455m [K=1.0000] Operators:DavidTest Date:2015-09-11Remarks:

BEST TEST SERVICE SHENZHEN CO.,LTDPage 1 Of 14

LUMINAIRE PHOTOMETRIC TEST REPORT

NAME:

SPEC.:

MFR.: Leedarson

TYPE:DL-N6A19FR1-2790

DIM.:

SUR.:

WEIGHT:

SERIAL No.:

PROTECTION ANGLE:

Test:U:120.0V I:0.1485A P:17.58W PF:0.9863 Lamp Flux:1234.28x1 lm

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cdC0/180, 47.1,45.7

UNIT:cd

C90/270, 47.2,45.0

AVERAGE BEAM ANGLE(50%):92.5 DEG

0

120

240

360

480

600

LUMINOUS INTENSITY DISTRIBUTION DIAGRAMPLANAR ISOLUX DIAGRAM(UNIT:lx)

MH=1m

S(m)0

1

2

3

90

80

70

60

50

40

30

2010 0

C(DEG)

470410350290230

17058.029.017.05.80

DATA OF LAMPPHOTOMETRIC DATAEff: 70.21 lm/W

MODEL

NOMINAL POWER(W)

RATED VOLTAGE(V)

NOMINAL FLUX(lm)

LAMPS INSIDE

TEST VOLTAGE(V)

Imax(cd)

LOR(%)

TOTAL FLUX(lm)

CIE CLASS

up(%)

down(%)

S/MH(C0/180)

S/MH(C90/270)

UP,DN(C0-180)

UP,DN(C180-360)

CIBSE SHR NOM

CIBSE SHR MAX

DL-N6A19FR1-2790

18

120.0

1234.28

1

120.0

583.3

100.0

1234.3

DIRECT

0.0

100.0

1.17

1.17

0.0,51.4

0.0,48.6

1.25

1.30

C Range: 0 - 360DEGC Interval: 22.5DEG

Range: 0 - 180DEG Interval: 1.0DEG

Test Speed: HIGHTest System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287Temperature:25.6DEGHumidity:67.1%

Test Distance:2.455m [K=1.0000] Operators:DavidTest Date:2015-06-18Remarks:

AR-DL2256DMF DH6ICAQ

Elite B6ICJuno IC21June IC20Juno IC22

Halo H5RICATHalo H7ICAT

Halo H27ICATHalo H5T

Halo H750ICATHalo H272ICAT

Halo H7ICTHalo H27T

Halo H25ICATLithonia L7XPHCR6

Lithonia LC6Philips PR75ASIC

AR-DL2240Commercial Electric HBR2000R (H10)Commercial Electric HBR2000B (H9)

Elite B4ICHalo H99ICATHalo H99TATHalo H99RTJuno TC1Juno IC1

Lithonia L3RLithonia L3U

Aurora Lighting Inc., 12035 34th St N, Suite 2, St Petersburg, FL 33716, USA

Document Version IS_AR-DL22xxV2Website: www.auroralighting.com Email: [email protected]

LED RETROFIT TRIM

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

IMPORTANT INSTALLATION INFORMATION

WARNINGRISK OF ELECTRIC SHOCK

•Disconnect power before performing installation or maintenance.

•Verify that supply voltage is correct by comparing it with the luminaire label information.

•Make all electrical grounded connections in accordance with the latest edition of the National Electric Code (NEC) and applicable local code requirements.

•If the supply wire is damaged, it must be replaced by the manufacturer or their service agent or a similar qualified person in order to avoid a hazard.

•All wiring connections should be capped with UL approved wire connectors.

•This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved.

•Connect fixture to a 120 volt,60 Hz power source. Any other connection voids the warranty.

WARNING CAUTION

•Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.

•If electrical appliances are disposed of in landfill or dumps, hazardous substances can be damaging to health and well-being.

•Contact your local government for information regarding the collection system available.

•This device is not intended for use with emergency exit fixtures or emergency exit lights.

•To reduce the risk of electrical shock, do not remove cover and caps, fitting must be grounded.

•No user-serviceable parts inside.•Do not use when enclosure is broken.•To prevent wiring damage or abrasion do not expose

wiring to edges of sheet metal or other sharp objects.•Indoor use only.

WARNINGRISK OF BURNS

•Follow all manufacturer’s warnings and recommendations for the luminarie installation methods, replacement and recycling.

•Luminaire not suitable for covering with thermally insulating material unless installed in an IC Rated Housing. Please ensure there is no thermal insulation within 200mm of the luminaire when not installed in an IC Rated Housing.

WARNINGRISK OF FIRE

•Keep any combustible and other materials that can burn away from the luminaire.

•Incorrect installation may result in electrical shock or a risk of a fire.

•MINIMUM 90°C SUPPLY CONNECTIONS

For Models: AR-DL2240/27, AR-DL2240/30, AR-DL2240/40, AR-DL2240/50AR-DL2256/27, AR-DL2256/30, AR-DL2256/40, AR-DL2256/50

Document Version - IS_AR-LP1xxXXXX V2_15Last Revised - 08/21/15

Website: www.auroralighting.com Email: [email protected]

LED FLAT PANEL

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATIONLEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

IMPORTANT INSTALLATION INFORMATION

WARNING

RISK OF ELECTRIC SHOCK

Disconnect power before performing installation or maintenance

Verify that supply voltage is correct by comparing it with the luminaire label information.

Make all electrical grounded connections in accordance with the latest edition of the National Electric Code (NEC) and applicable local code requirements.

If the supply wire is damaged. It must be replaced by the manufacturer or its service agent or a similar qualifi ed person in order to avoid a hazard.

All wiring connections should be capped with UL approved wire connections.

To reduce the risk of fi re or electrical shock, do not expose this apparatus to rain or moisture.

WARNING CAUTION

Suitable for mounting on normally fl ammable surfaces.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.

If electrical appliances are disposed of in landfi ll or dumps, hazardous substances can be damaging to health and well-being.

Contact your local government for information regarding the collection system available.

This device is not intended for use with emergency exit fi xtures or emergency exit lights.

To reduce the risk of electrical shock, do not remove cover and caps, fi tting must be grounded.

No user-serviceable parts inside.

Do not use when enclosure is broken.

To prevent wiring damage or abrasion does not expose wiring to edges of sheet metal or other sharp objects.

Indoor use only.

This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved

Vapor barrier must be suitable for 90ºc

WARNING

RISK OF BURNS

Do not exceed maximum wattage on luminaire label.

Follow all manufacturer’s warnings and recommendations for the driver type, mounting position, methods, replacements and recycling.

WARNING

RISK OF FIRE

Keep any combustable and other materials that can burn away form the luminaires.

Incorrect installation may result in electrical shock or a risk of a fi re

For Models

1x4 (40W)AR-LP114BDD/35AR-LP114BDD/40AR-LP114BDD/50

2x2 (30W)AR-LP122B3DD/35AR-LP122B3DD/40AR-LP122B3DD/50

2x2 (40W)AR-LP122BDD/35AR-LP122BDD/40AR-LP122BDD/50

2x2 (60W)AR-LP122B6DD/35AR-LP122B6DD/40AR-LP122B6DD/50

2x4 (50W)AR-LP124BDD/35AR-LP124BDD/40AR-LP124BDD/50

2x4 (75W)AR-LP124B7DD/35AR-LP124B7DD/40AR-LP124B7DD/50

1 4

Document Version - IS_AR-LP1xxXXXX V2_15Last Revised - 08/21/15

Website: www.auroralighting.com Email: [email protected]

LED FLAT PANEL

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATIONLEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

IMPORTANT INSTALLATION INFORMATION

WARNING

RISK OF ELECTRIC SHOCK

Disconnect power before performing installation or maintenance

Verify that supply voltage is correct by comparing it with the luminaire label information.

Make all electrical grounded connections in accordance with the latest edition of the National Electric Code (NEC) and applicable local code requirements.

If the supply wire is damaged. It must be replaced by the manufacturer or its service agent or a similar qualifi ed person in order to avoid a hazard.

All wiring connections should be capped with UL approved wire connections.

To reduce the risk of fi re or electrical shock, do not expose this apparatus to rain or moisture.

WARNING CAUTION

Suitable for mounting on normally fl ammable surfaces.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.

If electrical appliances are disposed of in landfi ll or dumps, hazardous substances can be damaging to health and well-being.

Contact your local government for information regarding the collection system available.

This device is not intended for use with emergency exit fi xtures or emergency exit lights.

To reduce the risk of electrical shock, do not remove cover and caps, fi tting must be grounded.

No user-serviceable parts inside.

Do not use when enclosure is broken.

To prevent wiring damage or abrasion does not expose wiring to edges of sheet metal or other sharp objects.

Indoor use only.

This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved

Vapor barrier must be suitable for 90ºc

WARNING

RISK OF BURNS

Do not exceed maximum wattage on luminaire label.

Follow all manufacturer’s warnings and recommendations for the driver type, mounting position, methods, replacements and recycling.

WARNING

RISK OF FIRE

Keep any combustable and other materials that can burn away form the luminaires.

Incorrect installation may result in electrical shock or a risk of a fi re

For Models

1x4 (40W)AR-LP114BDD/35AR-LP114BDD/40AR-LP114BDD/50

2x2 (30W)AR-LP122B3DD/35AR-LP122B3DD/40AR-LP122B3DD/50

2x2 (40W)AR-LP122BDD/35AR-LP122BDD/40AR-LP122BDD/50

2x2 (60W)AR-LP122B6DD/35AR-LP122B6DD/40AR-LP122B6DD/50

2x4 (50W)AR-LP124BDD/35AR-LP124BDD/40AR-LP124BDD/50

2x4 (75W)AR-LP124B7DD/35AR-LP124B7DD/40AR-LP124B7DD/50

1 4

Page 2: 295*195mm - db.aurora.co.s3.amazonaws.comdb.aurora.co.s3.amazonaws.com/FamilyData/23334/13426/FileUpload/... · WARRANTY: This product has a warranty of period of 5 years from the

SECTION #2: 5-6 INCH (AR-DL2256) INSTALLATION METHOD:

1. IMPORTANT: Always switch off the power supply before before installation or maintenance. 2. Remove socket mounting bracket and plate from inside of existing recessed CAN (if installed).

• Ensure bottom edge of CAN is flush with ceiling. Adjust height if necessary to ensure the CAN is flush.3. Release socket from plate (if installed).4. Place gasket on trim ring flange.5. Screw medium base adapter into existing medium base socket in CAN (Fig 4.1).6. Plug male end of orange connector on LED Retrofit Trim into the female end of orange connector on screw base adapter (Fig 4.2 and 4.3).7. Install ground wire (See SECTION #1)8. Squeeze the torsion spring clips together and install into spring clip brackets inside CAN (Fig 4.4).9. Carefully route wires into fixture and push trim up flush to ceiling surface (Fig 4.5). 10. Turn on power supply to ensure the fixture is operating properly. SECTION #3: REMOVING LED RETROFIT TRIM

1. IMPORTANT: Always switch off the power supply before before installation or maintenance. 2. With fingertips, pull down firmly on trim ring until module is removed from the can.3. Squeeze torsion spring clips together to remove LED Trim. If using tension clips, pull module out of CAN slowly.4. Disconnect LED Retrofit Trim wiring from recessed can (LED connector or screw-in medium base adaptor)

B: To install the module in a 6 inch CAN, unscrew the torsion spring bracket screws, adjust to 6inch slot

and retighten.(Figure 3.1 - Position “B”)

NOTE: Confirm CAN is compatible with retrofit trims.

Figure 3.1

B

6 inch

Figure 4.1 Figure 4.2 Figure 4.3 Figure 4.5Figure 4.4

IMPORTANT: READ CAREFULLY BEFORE INSTALLING LUMINAIRE. RETAIN FOR FUTURE REFERENCE.Always wear gloves when installing to keep the fixture clean.

Fixture should be installed by persons with experience in household wiring or by a qualified electrician. The electrical system, and method of electrically connecting the fixture to it, must be in accordance with the National Electrical Code and local building codes.

• This device complies with Part 15 of the FCC Rules.• Operation is subject to the following two conditions: o This device may not cause harmful interference o This device must accept any interference received including interference that may cause undesired operation.

SECTION #1: 4 INCH (AR-DL2240) INSTALLATION METHOD:NOTE: Confirm CAN is compatible with retrofit trims.

1. IMPORTANT: Always switch off the power supply before before installation or maintenance. 2. Remove socket mounting bracket and plate from inside of existing recessed CAN (if installed).

a. Ensure bottom edge of CAN is flush with ceiling. Adjust height if necessary to ensure the CAN is flush.3. Release socket from plate (if installed).4. Place gasket on trim ring flange.5. Screw medium base adapter into existing medium base socket in CAN (Fig 2.1). 6. Plug male end of orange connector on LED Retrofit Trim into the female end of orange connector on screw base adapter (Fig 2.2 and 2.3).7. Install ground wire (See SECTION #1)8. Squeeze the opposing tension clips toward the luminaire until the clips fit inside the CAN then carefully insert LED Retrofit Trim into CAN

allowing springs to expand to hold Trim in CAN (Fig 2.4).9. Carefully route wires into fixture and push trim up flush to ceiling surface.10. Turn on power supply to ensure the fixture is operating properly.

Figure 2.1 Figure 2.2 Figure 2.3 Figure 2.4

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE.GENERAL:

INSTALLATION INSTRUCTIONS:

1. Turn off main power before installing.

2. Remove the ceiling panel or fl uorescent fi xture and disconnect wiring and any mounting brackets that were used if any. (Figure 1)

3. Fix safety cable mounting brackets to the LED panel (Figure 2).

5. Remove the junction box cover on the back of the LED panel.

4. Connect the Line, Neutral and Ground wires from the supply side to the LED driver (Figure 3) inside the junction box through the supply side knockout hole using an appropriate connector to secure the supply line to the junction box. Additional steps are required for dimming models (See Page 3).

6. Replace the cover on the junction box. Fit the fl at LED panel into the ceiling and attach safety cable to safety cable mounting brackets and secure the safety cable to the building per the requirements of local building codes or to meet local seismic requirements (Figure 4).

7. Turn on main power and test panel.

DIMMABLE WIRING INSTRUCTIONS:

Dimmable models come with an additional knockout hole in the junction box on the dimming side of the LED driver.

To wire multiple dimming panels to one standard 0-10v dimmer use the schematic below. The maximum number of panels that can be dimmed depends on the capability and capacity of the dimmer. Wire using plenum rated low voltage wire and appropriate connector.

NON-DIMMING WIRING INSTRUCTIONS:

WARRANTY

This product has a warranty of period of 5 years from the date of purchase. The warranty is invalid in the case of improper use, installation, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National Electric Code. Should this product fail during the warranty period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifi cations without prior notice.

LED Driver

Switch

L L (Brown) DIM+ (Blue)

N N (Blue) DIM-

G (Green)

(White)Do not connect the DIM+ and DIM- wires to a dimmer.Add a wirenut to the end of each wire to insulate it.

LED Panel Junction Box

2 3IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE.GENERAL:

INSTALLATION INSTRUCTIONS:

1. Turn off main power before installing.

2. Remove the ceiling panel or fl uorescent fi xture and disconnect wiring and any mounting brackets that were used if any. (Figure 1)

3. Fix safety cable mounting brackets to the LED panel (Figure 2).

5. Remove the junction box cover on the back of the LED panel.

4. Connect the Line, Neutral and Ground wires from the supply side to the LED driver (Figure 3) inside the junction box through the supply side knockout hole using an appropriate connector to secure the supply line to the junction box. Additional steps are required for dimming models (See Page 3).

6. Replace the cover on the junction box. Fit the fl at LED panel into the ceiling and attach safety cable to safety cable mounting brackets and secure the safety cable to the building per the requirements of local building codes or to meet local seismic requirements (Figure 4).

7. Turn on main power and test panel.

DIMMABLE WIRING INSTRUCTIONS:

Dimmable models come with an additional knockout hole in the junction box on the dimming side of the LED driver.

To wire multiple dimming panels to one standard 0-10v dimmer use the schematic below. The maximum number of panels that can be dimmed depends on the capability and capacity of the dimmer. Wire using plenum rated low voltage wire and appropriate connector.

NON-DIMMING WIRING INSTRUCTIONS:

WARRANTY

This product has a warranty of period of 5 years from the date of purchase. The warranty is invalid in the case of improper use, installation, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National Electric Code. Should this product fail during the warranty period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifi cations without prior notice.

LED Driver

Switch

L L (Brown) DIM+ (Blue)

N N (Blue) DIM-

G (Green)

(White)Do not connect the DIM+ and DIM- wires to a dimmer.Add a wirenut to the end of each wire to insulate it.

LED Panel Junction Box

2 3