22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and...
-
Upload
prosper-turner -
Category
Documents
-
view
219 -
download
2
Transcript of 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and...
![Page 1: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/1.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 1/27
CLIC_ILD particle identification and tracking performance
J. Nardulli
This talk in 2 parts:Particle-ID performance: efficiencies, purities and mis-identification rateTracking performance: efficiency and fake rate
![Page 2: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/2.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 2/27
Part 1: Particle-Identification performance in CLIC_ILD
![Page 3: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/3.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 3/27
The particle-ID algorithm• For Efficiency and purity we take a list of MC-Particle and
PFO of same PDG type• Create lists of findable PFOs and MC-Particles
– Cuts used• Energy > 7.5 GeV• Polar angle > 8 degrees• MC-Particles with Generator status equal to 1
• Match Energy and PFO on direction and Energy– Direction: PFO and MC-Particle inside a 1 degree cone– Energy/Momentum
• For charged particles:• For neutral particles :
• Similarly when requiring to have particles with different PDG type, we look at the mistag rate
![Page 4: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/4.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 4/27
The particle-ID algorithm• For Efficiency and purity we take a list of MC-Particle and
PFO of same PDG type• Create lists of findable PFOs and MC-Particles
– Cuts used• Energy > 7.5 GeV• Polar angle > 8 degrees• MC-Particles with Generator status equal to 1
• Match Energy and PFO on direction and Energy– Direction: PFO and MC-Particle inside a 1 degree cone– Energy/Momentum
• For charged particles:• For neutral particles :
• Similarly when requiring to have particles with different PDG type, we look at the mistag rate
![Page 5: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/5.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 5/27
The particle-ID algorithm• For Efficiency and purity we take a list of MC-Particle and
PFO of same PDG type• Create lists of findable PFOs and MC-Particles
– Cuts used• Energy > 7.5 GeV• Polar angle > 8 degrees• MC-Particles with Generator status equal to 1
• Match Energy and PFO on direction and Energy– Direction: PFO and MC-Particle inside a 1 degree cone– Energy/Momentum
• For charged particles:• For neutral particles :
• Similarly when requiring to have particles with different PDG type, we look at the mistag rate
![Page 6: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/6.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 6/27
The particle-ID algorithm• For Efficiency and purity we take a list of MC-Particle and
PFO of same PDG type• Create lists of findable PFOs and MC-Particles
– Cuts used• Energy > 7.5 GeV• Polar angle > 8 degrees• MC-Particles with Generator status equal to 1
• Match Energy and PFO on direction and Energy– Direction: PFO and MC-Particle inside a 1 degree cone– Energy/Momentum
• For charged particles:• For neutral particles :
• Similarly when requiring to have particles with different PDG type, we look at the mistag rate
![Page 7: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/7.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 7/27
DefinitionsEfficiency: matched MCParticles/findable MCParticles
Purity: Matched PFOs/findable PFOs
Mistag rate: matched –different PDG- MCParticles/findable MCParticles
These definitions are per MCParticle and per Event
Plots in the next slides produced with particle guns electrons, photons, muons and pions generated in all the θ and φ spectrum with energies up to 400 GeV
![Page 8: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/8.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 8/27
Electrons: Efficiency
vs. θ
vs. Energy
40%
60%
100%
80%
75%
100%
90%
85%80%
![Page 9: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/9.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 9/27
Electrons: Purity
vs. θ
vs. Energy
75%
100%
90%
85%80%
75%
100%
90%
85%80%
![Page 10: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/10.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 10/27
Photons: Efficiency
vs. θ
vs. Energy
80%
65%
100%
90%
75%
100%
90%
85%80%
![Page 11: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/11.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 11/27
Photons: Purity
vs. θ
vs. Energy
80%
65%
100%
90%
75%
100%
90%
85%
80%
![Page 12: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/12.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 12/27
Pions: Efficiency
vs. θ
vs. Energy
40%
60%
100%
80%
75%
100%
90%85%
80%
![Page 13: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/13.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 13/27
Pions: Purity
vs. θ
vs. Energy
75%
100%
90%85%
75%
100%
90%
85%
![Page 14: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/14.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 14/27
Muons: Efficiency and purity for 10 GeV particles
Efficiency vs. θ
Purity vs. θ
85%
90%
95%
100%
85%
90%
95%
100%
![Page 15: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/15.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 15/27
Muons: Efficiency for Zbb events
vs. θ
vs. Energy
50%
100%90%
70%
50%
100%90%
70%
![Page 16: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/16.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 16/27
Average efficiency and purity for all particles in CLIC_ILD_CDR
Plots in the previous slides produced with particle guns electrons, photons, muons and pions generated in all the θ and φ spectrum with energies up to 400 GeV
![Page 17: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/17.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 17/27
Average mistag rate per eventfor all particles in CLIC_ILD_CDR
Mis
tag
rate
[%]
![Page 18: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/18.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 18/27
Conclusions
Efficiency and Purity•Efficiency and purity are above 90% for all particles considered
Mistag rate•Apart from the less interesting 1 GeV case•For 100 and 500 GeV for all particles the mistag rate is always < 2%•At 10 GeV we have higher values for electrons, mostly mistagged as pions•Mistagged Pions are found mostly at PFO level as electrons•Gammas are found as neutrons and Pions
![Page 19: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/19.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 19/27
Part 2: Tracking performance in CLIC_ILD
![Page 20: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/20.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 20/27
Tracking performance algorithm • For the Tracking Efficiency we make a list of findable MC-Particles
– Cuts used• Energy > 250 MeV• Polar angle > 8 degrees• Charge different from 0• Flight distance cut Default value > 50 mm• |Origin of MC – interaction point| Default value < 50 mm
• Then Loop over all the tracks and all the MC-Particles• For every track try to match it to a MCParticle
– If you succeed and your MC Particle is findable you’re efficient– If you succeed and your MC Particle is NOT findable your track is not a
fake– If you do not succeed, your track is a fake
• Matching Criteria: – Nr of hits of a track, that belong to the MCParticle you want to match > 75%
![Page 21: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/21.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 21/27
Tracking performance algorithm • For the Tracking Efficiency we make a list of findable MC-Particles
– Cuts used• Energy > 250 MeV• Polar angle > 8 degrees• Charge different from 0• Flight distance cut Default value > 50 mm• |Origin of MC – interaction point| Default value < 50 mm
• Then Loop over all the tracks and all the MC-Particles• For every track try to match it to a MCParticle
– If you succeed and your MC Particle is findable you’re efficient– If you succeed and your MC Particle is NOT findable your track is not a
fake– If you do not succeed, your track is a fake
• Matching Criteria: – Nr of hits of a track, that belong to the MCParticle you want to match > 75%
![Page 22: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/22.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 22/27
Tracking performance algorithm • For the Tracking Efficiency we make a list of findable MC-Particles
– Cuts used• Energy > 250 MeV• Polar angle > 8 degrees• Charge different from 0• Flight distance cut Default value > 50 mm• |Origin of MC – interaction point| Default value < 50 mm
• Then Loop over all the tracks and all the MC-Particles• For every track try to match it to a MCParticle
– If you succeed and your MC Particle is findable you’re efficient– If you succeed and your MC Particle is NOT findable your track is not a
fake– If you do not succeed, your track is a fake
• Matching Criteria: – Nr of hits of a track, that belong to the MCParticle you want to match > 75%
![Page 23: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/23.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 23/27
Definitions
Efficiency: matched Tracks/findable MCParticles
Fake Rate: Not Matched Tracks/All Tracks
![Page 24: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/24.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 24/27
Results: Signal Efficiency
vs. vs. θθWithout background overlaidWithout background overlaid
vs. Momentumvs. Momentum
Without background Without background the fake rate is at 0.005%the fake rate is at 0.005%
• Particle gun muons generated in all the θ and φ spectrum up to 400 GeV• Reconstructed with and without background overlay [60 bunches of γγ hadrons]
![Page 25: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/25.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 25/27
Results: Signal Efficiency• Particle gun muons generated in all the θ and φ spectrum up to 400 GeV• Reconstructed with and without background overlay [60 bunches of γγ hadrons]
vs. vs. θθWithWith background overlaid background overlaid
vs. Momentumvs. Momentum
With background With background the fake rate is at ~10% the fake rate is at ~10% see next slide see next slide
![Page 26: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/26.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 26/27
Results: Fake rate
vs. vs. θθ vs. Ptvs. Pt
WithWith background overlaid background overlaid
• Particle gun muons generated in all the θ and φ spectrum up to 400 GeV• Reconstructed with and without background overlay [60 bunches of γγ hadrons]
![Page 27: 22/5/2011 Particle-ID and Tracking performance in CLIC_ILD1/27 CLIC_ILD particle identification and tracking performance J. Nardulli This talk in 2 parts:](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649d0d5503460f949e2895/html5/thumbnails/27.jpg)
22/5/2011 Particle-ID and Tracking performance in CLIC_ILD 27/27
Conclusions• For single muons without overlaid background the tracking
efficiency is ~100% and the fake rate is at 0.005%• The overlaid background does NOT deteriorate the tracking
efficiency for single muons
• While it increases the fake rate which goes to ~10%