    2+2 swap to 4+0 guide

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    2/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. I

    TABLE OF CONTENTS

    1 Introduce ........................................................................................................... II

    2 The preparation for cutover ........................................................................ III

    3 The operation of the specific ....................................................................... III3.1 Protection mode ................................................................................................ III3.2 Frequency ......................................................................................................... IV3.3 Hybrid Reversal .................................................................................................. V3.4 Switch Configuration ....................................................................................... VIII

    3.5

    NMS Connection

    ............................................................................................. VIII3.5.1 Near End Connection ...................................................................................... VIII3.5.2 Far End Connection .......................................................................................... IX3.5.3 Microwave Configuration ................................................................................... IX

    4 After Cutover .................................................................................................. XI4.1 Check the IDU panel alarm ............................................................................... XI4.2 Check BTS Information .................................................................................... XII4.3 Check the performance report ......................................................................... XII4.3.1 Check the Aggregate PM Report ..................................................................... XII4.3.2 Check the Signal Level ................................................................................... XIII4.3.3 Check the MSE ............................................................................................... XIII

    4.3.4

    Check the XPI

    ................................................................................................. XIV

    5 Rollback Plan ................................................................................................ XIV

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    3/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. II

    1 Introduce

    4+0 configuration with S340 is actually 2*(2+0) XPIC in a nodal. Four IDUs are

    installed in two enclosures, two IDUs in main enclosure build a 2+0 XPIC, and other

    two IDUs in expansion enclosure building another 2+0 XPIC.

    Now we need reuse the 2+2 XPIC material, we can use the two main enclosures

    build two 2+0 XPIC links!

    This configuration guide describes the procedures to make a 2+0 XPCI terminal

    working in one enclosure, repeat the same procedures for the IDUs in another

    enclosure. The following procedures are related to link configuration, other setting,

    link general information, and so on.

    The following is the 2+2 to 4+0 manual guide.

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    4/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. III

    2 The preparation for cutover

    (1) The preparation of the tools and instrumentation, software version and system

    network scheme, etc.

    (2) Check IF cable with corresponding labels! In order to make a distinction between

    polarization and ODU!

    (3) Telnet the IDU, take the capture about the license, protection mode,

    MRMC,RSL,XPD,MSE and so on .In order to make sure reach the KPI after the

    cutover to the 4+0.

    (4) Telnet the IDU, check the IP and remark, use the same ip after cutover.

    3 The operation of the specific

    3.1 Protection mode

    (1)Change two IDUs protection mode in the standby enclosure to disable, and then

    change the two IDUs protection mode in the main enclosure to disable. Next step,

    remove the protection cable.

    2+2 XPIC Protection Configuration

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    5/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. IV

    4+0 Protection Configuration

    3.2 Frequency

    (1)Change the standby enclosure IDU V and H frequency to the other frequency

    which is scanning frequency result! 2+2 link use the one pair frequency and

    4+0(2*(2+0)) use the two pairs frequency.

    2+2 XPIC frequency

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    6/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. V

    4+0 frequency

    3.3 Hybr id Reversal

    In order to guarantee same loss, we need to reversal the Hybrid. We can move one

    site the IF cable in main enclosure1 to the main enclosure2. Next step, move the IF

    cable in main enclosure2 to the main enclosure1. Please find the following picture

    about the 2+2 XPCI and 4+0.

    2+2 Connection Chart

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    7/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. VI

    4+0 Connection Chart

    The following chart is the whole chart which 2+2 cutover to 4+0 scheme. All Carriers are working as

    transparent channels. Four carries are connected to ZTE switching individually. Layer 2 aggregation is

    done on ZTE switch for 4+0 protection.

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    8/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. VII

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    9/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. VIII

    3.4 Switch Configuration

    The 4+0 switch mode use the single pipe same as the 2+2 switch mode. No need to

    change the switch mode.

    3.5 NMS Connection

    3.5.1 Near End Connect ion

    In 4+0 mode, the connection is shown.

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    10/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. IX

    3.5.2 Far End Connect ion

    In 4+0 mode, the connection is shown.

    3.5.3 Microwave Configuration

    The configuration of both site is the same.

    3.5.3.1 Management Ports

    The path of management ports is shown.

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    11/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. X

    Managements Ports Configuration

    3.5.3.2 Wayside

    The path of wayside and configuration is shown in below!

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    12/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. XI

    3.5.3.3 Switch Configuration

    Additional Ethernet port is needed in the near end site for EMS.

    The configuration is shown.

    Auto-negotiation: OFF

    Speed: 100M

    Duplex: Full

    Mode: Access

    4 After Cutover

    4.1 Check the IDU panel alarm

    After cutover, you need to check the IDU alarm in the panel , make sure no critical

    alarm, if have alarm in the IDU panel, please find the reason and clear the alarm.

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    13/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. XII

    4.2 Check BTS Information

    After cutover, we guarantee the BTS is up. Please call the BSC guys to check the site

    status.

    4.3 Check the perfo rmance repor t

    After cutover, please check the Aggregate PM report and signal level and MSE and XPI,

    All the performance need reach the KPI.

    4.3.1 Check the Aggregate PM Report

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    14/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. XIII

    4.3.2 Check the Signal Level

    4.3.3 Check the MSE

  • 8/10/2019 2+2 XPIC swap to 4+0 guide

    15/16

    2+2 swap to 4+0 guide Internal Use Only

    ZTE Confidential Proprietary 2013 ZTE CORPORATION. All rights reserved. XIV

    4.3.4 Check the XPI

    5 Rollback Plan

    Any upgrade failed, we will rollback to 2+2 link to ensure BTS still can works

    normally. Then we will analyze the reason.