204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW...

29
© blt architects 2019 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos 07 existing site plan 08 site and landscape plan 09 floor plans 14 massing in context 15 sections & elevations 18 renderings & materials 22 complete streets handbook checklist 28 sustainable design checklist

Transcript of 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW...

Page 1: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

© blt architects 2019

204 s 12th streetCIVIC DESIGN REVIEW

07.21.2020

civic design review

01 cdr project application form 02 area map 03 site photos 07 existing site plan 08 site and landscape plan 09 floor plans 14 massing in context 15 sections & elevations 18 renderings & materials 22 complete streets handbook checklist 28 sustainable design checklist

Page 2: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 1application form

Page 1 of 2

CDR PROJECT APPLICATION FORM Note: For a project appl icat ion to be cons idered for a Civ ic Des ign Rev iew agenda, complete and accurate submitta ls mus t be received no later than 4 P.M. on the submiss ion date. A submiss ion does not guarantee p lacement on the agenda of the next CDR meet ing date.

L&I APPLICATION NUMBER: ZP-2020-000710C

What is the trigger causing the project to require CDR Review? Explain briefly.

The proposed project includes the creation of more than 100,000 sq. ft. of new gross floor area and the creation of more than 100 dwelling units.

PROJECT LOCATION

CONTACT INFORMATION

Planning District: Central Council District: 1

Address: 200-204 S. 12th Street

Is this parcel within an Opportunity Zone? Yes No X Uncertain If yes, is the project using Opportunity Zone Funding?

Yes No X

Applicant Name: David Gest, Esq. Primary Phone: 215-864-8143

Email: [email protected] Address: Ballard Spahr LLP 1735 Market Street, Philadelphia, PA

19103

Property Owner: South 12th Street Owner LLC; 200 South 12th Street Owner LLC

Developer Midwood Investment & Development

Architect: BLT Architects

Page 2 of 2

SITE CONDITIONS

SITE USES

COMMUNITY MEETING

ZONING BOARD OF ADJUSTMENT HEARING

Community meeting held: Yes No X

If yes, please provide written documentation as proof.

If no, indicate the date and time the community meeting will be held:

Date: TBD Time: TBD

Present Use: Office/daycare Proposed Use:

Area of Proposed Uses, Broken Out by Program (Include Square Footage and # of Units):

350,253 sq. ft. multi-family residential use (448 dwelling units) 39,999 sq. ft. retail use 41,380 sq. ft. below grade parking garage Proposed # of Parking Units:

68 parking spaces

Site Area: 18,434.4 sq. ft. Existing Zoning: CMX-5 w/

overlays Are Zoning Variances required? Yes No X

ZBA hearing scheduled: Yes No NA__X____

If yes, indicate the date hearing will be held:

Date:

Page 3: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 2area map

Page 4: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 3

view from 12th & st james looking north view from 12th & st james looking west

S C

AMAC

STR

EET

12TH

STR

EET

ST. JAMES STREET

CHANCELLOR STREET

A1

Z-202

AA4

Z-202

A4

Z-201

A1

Z-201

A1Z-301

PROPERTY LINE

33'-9" 81'-9"

9'-8" 115'-6"

EXISTING CAMAC BUILDING ROOF

EXISTING FRANKLIN BUILDING ROOF

MECHANICAL ROOFRESIDENTIAL AMENITY DECK

24'-1

"60

'-7"

6'-10" 72'-5" 115'-6" 12'-3"

8'-1" 24'-6" 82'-11"

6'-8

"0"

110'

-3"

6'-9

"

8'-1" 16'-8" 90'-9" 0" 12'-2"

T.O. ELEV. PENTHOUSE ROOF 425' - 0"

110'

-3"

T.O. AMENITY PARAPET 303' - 6"

T.O. AMENITY ROOF 300' - 0"

5'-0

"

GUARDRAIL

32'-5

"

T.O. MECHANICAL SCREEN 435' - 0"

36'-2

"37

'-0"

56'-5" 16'-0"

T.O. ROOF 42' - 0"

T.O. PARAPET 43' - 0"

T.O. MECHANICAL ROOM 410' - 0"

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

E

A

B

C

D

E

BLT A

RC

HITE

CTS 1216 A

RC

H S

TRE

ET S

UITE

800 PH

ILAD

ELP

HIA

PE

NN

SY

LVA

NIA

PH

ON

E 215.563.3900 FA

X 215.563.3036

PROJECT TITLE

CLIENT

CIVIL ENGINEER

STRUCTURAL ENGINEER

MEP / AV / IT ENGINEER

VERTICAL TRANSPORTATION

ACOUSTICAL

LIGHTING

SEAL

MIDWOOD INVESTMENT & DEVELOPMENT430 PARK AVENUE, 505NEW YORK, NY 10022

BOHLER ENGINEERING1515 MARKET STREETSUITE 920PHILADLEPHIA, PA 19102

WSP USAONE PENN PLAZA250 W 34TH STREETNEW YORK, NY 10119

BALA CONSULTING ENGINEERS443 SOUTH GULPH ROADKING OF PRUSSIA, PA 19406

VDA (VAN DUESEN & ASSOCIATES221 LAUREL ROADSUITE 130VOORHEES, NJ 08043

LONGMAN LINDSEY200 WEST 41ST STREET, SUITE 1100NEW YORK, NY 10036

THE LIGHTING PRACTICETHE PUBLIC LEDGER BUILDING600 CHESTNUT STREET, SUITE 772PHILADLEPHIA, PA 19106

PROJECT NO FIRST ISSUE DATE

FILE SCALE

REVIEWEDDRAWN BY

NO ISSUE NAME DATE

SHEET TITLE

SHEET NO

@C

OP

YR

IGH

T 20

16: B

LT A

RC

HIT

EC

TS

1/8" = 1'-0"

4/10

/202

0 2:

25:5

7 PM

C:\U

sers

\NN

asis

\Doc

umen

ts\1

8120

00-A

_202

0_nn

asis

@bl

ta.c

om.rv

t

204 S 12TH STREET204 S 12TH STREETPHILADELPHIA, PA19107

1812000 3/23/2020

NPN BD

ZONING ROOF PLAN

Z-101

Z-10

1 ZO

NIN

G R

OO

F PL

AN 3

/23/

2020

Scale: 1/8" = 1'-0"B1 ROOF PLAN

ZONING SET 02 FEBRUARY 2020

ZONING DRAWING LIST

SHEETNUMBER SHEET NAME

Z-101 ZONING ROOF PLANZ-102 ZONING FLOOR PLANSZ-103 ZONING FLOOR PLANSZ-201 ZONING ELEVATIONSZ-202 ZONING ELEVATIONSZ-301 ZONING SECTIONS site photos

Page 5: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 4

view from 12th and chancellor looking south view from 12th & chancellor looking west

S C

AMAC

STR

EET

12TH

STR

EET

ST. JAMES STREET

CHANCELLOR STREET

A1

Z-202

AA4

Z-202

A4

Z-201

A1

Z-201

A1Z-301

PROPERTY LINE

33'-9" 81'-9"

9'-8" 115'-6"

EXISTING CAMAC BUILDING ROOF

EXISTING FRANKLIN BUILDING ROOF

MECHANICAL ROOFRESIDENTIAL AMENITY DECK

24'-1

"60

'-7"

6'-10" 72'-5" 115'-6" 12'-3"

8'-1" 24'-6" 82'-11"

6'-8

"0"

110'

-3"

6'-9

"

8'-1" 16'-8" 90'-9" 0" 12'-2"

T.O. ELEV. PENTHOUSE ROOF 425' - 0"

110'

-3"

T.O. AMENITY PARAPET 303' - 6"

T.O. AMENITY ROOF 300' - 0"

5'-0

"

GUARDRAIL

32'-5

"

T.O. MECHANICAL SCREEN 435' - 0"

36'-2

"37

'-0"

56'-5" 16'-0"

T.O. ROOF 42' - 0"

T.O. PARAPET 43' - 0"

T.O. MECHANICAL ROOM 410' - 0"

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

E

A

B

C

D

E

BLT A

RC

HITE

CTS 1216 A

RC

H S

TRE

ET S

UITE

800 PH

ILAD

ELP

HIA

PE

NN

SY

LVA

NIA

PH

ON

E 215.563.3900 FA

X 215.563.3036

PROJECT TITLE

CLIENT

CIVIL ENGINEER

STRUCTURAL ENGINEER

MEP / AV / IT ENGINEER

VERTICAL TRANSPORTATION

ACOUSTICAL

LIGHTING

SEAL

MIDWOOD INVESTMENT & DEVELOPMENT430 PARK AVENUE, 505NEW YORK, NY 10022

BOHLER ENGINEERING1515 MARKET STREETSUITE 920PHILADLEPHIA, PA 19102

WSP USAONE PENN PLAZA250 W 34TH STREETNEW YORK, NY 10119

BALA CONSULTING ENGINEERS443 SOUTH GULPH ROADKING OF PRUSSIA, PA 19406

VDA (VAN DUESEN & ASSOCIATES221 LAUREL ROADSUITE 130VOORHEES, NJ 08043

LONGMAN LINDSEY200 WEST 41ST STREET, SUITE 1100NEW YORK, NY 10036

THE LIGHTING PRACTICETHE PUBLIC LEDGER BUILDING600 CHESTNUT STREET, SUITE 772PHILADLEPHIA, PA 19106

PROJECT NO FIRST ISSUE DATE

FILE SCALE

REVIEWEDDRAWN BY

NO ISSUE NAME DATE

SHEET TITLE

SHEET NO

@C

OP

YR

IGH

T 20

16: B

LT A

RC

HIT

EC

TS

1/8" = 1'-0"

4/10

/202

0 2:

25:5

7 PM

C:\U

sers

\NN

asis

\Doc

umen

ts\1

8120

00-A

_202

0_nn

asis

@bl

ta.c

om.rv

t

204 S 12TH STREET204 S 12TH STREETPHILADELPHIA, PA19107

1812000 3/23/2020

NPN BD

ZONING ROOF PLAN

Z-101

Z-10

1 ZO

NIN

G R

OO

F PL

AN 3

/23/

2020

Scale: 1/8" = 1'-0"B1 ROOF PLAN

ZONING SET 02 FEBRUARY 2020

ZONING DRAWING LIST

SHEETNUMBER SHEET NAME

Z-101 ZONING ROOF PLANZ-102 ZONING FLOOR PLANSZ-103 ZONING FLOOR PLANSZ-201 ZONING ELEVATIONSZ-202 ZONING ELEVATIONSZ-301 ZONING SECTIONS site photos

Page 6: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 5

view from chancellor and camac looking south view from chancellor & camac looking east

S C

AMAC

STR

EET

12TH

STR

EET

ST. JAMES STREET

CHANCELLOR STREET

A1

Z-202

AA4

Z-202

A4

Z-201

A1

Z-201

A1Z-301

PROPERTY LINE

33'-9" 81'-9"

9'-8" 115'-6"

EXISTING CAMAC BUILDING ROOF

EXISTING FRANKLIN BUILDING ROOF

MECHANICAL ROOFRESIDENTIAL AMENITY DECK

24'-1

"60

'-7"

6'-10" 72'-5" 115'-6" 12'-3"

8'-1" 24'-6" 82'-11"

6'-8

"0"

110'

-3"

6'-9

"

8'-1" 16'-8" 90'-9" 0" 12'-2"

T.O. ELEV. PENTHOUSE ROOF 425' - 0"

110'

-3"

T.O. AMENITY PARAPET 303' - 6"

T.O. AMENITY ROOF 300' - 0"

5'-0

"

GUARDRAIL

32'-5

"

T.O. MECHANICAL SCREEN 435' - 0"

36'-2

"37

'-0"

56'-5" 16'-0"

T.O. ROOF 42' - 0"

T.O. PARAPET 43' - 0"

T.O. MECHANICAL ROOM 410' - 0"

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

E

A

B

C

D

E

BLT A

RC

HITE

CTS 1216 A

RC

H S

TRE

ET S

UITE

800 PH

ILAD

ELP

HIA

PE

NN

SY

LVA

NIA

PH

ON

E 215.563.3900 FA

X 215.563.3036

PROJECT TITLE

CLIENT

CIVIL ENGINEER

STRUCTURAL ENGINEER

MEP / AV / IT ENGINEER

VERTICAL TRANSPORTATION

ACOUSTICAL

LIGHTING

SEAL

MIDWOOD INVESTMENT & DEVELOPMENT430 PARK AVENUE, 505NEW YORK, NY 10022

BOHLER ENGINEERING1515 MARKET STREETSUITE 920PHILADLEPHIA, PA 19102

WSP USAONE PENN PLAZA250 W 34TH STREETNEW YORK, NY 10119

BALA CONSULTING ENGINEERS443 SOUTH GULPH ROADKING OF PRUSSIA, PA 19406

VDA (VAN DUESEN & ASSOCIATES221 LAUREL ROADSUITE 130VOORHEES, NJ 08043

LONGMAN LINDSEY200 WEST 41ST STREET, SUITE 1100NEW YORK, NY 10036

THE LIGHTING PRACTICETHE PUBLIC LEDGER BUILDING600 CHESTNUT STREET, SUITE 772PHILADLEPHIA, PA 19106

PROJECT NO FIRST ISSUE DATE

FILE SCALE

REVIEWEDDRAWN BY

NO ISSUE NAME DATE

SHEET TITLE

SHEET NO

@C

OP

YR

IGH

T 20

16: B

LT A

RC

HIT

EC

TS

1/8" = 1'-0"

4/10

/202

0 2:

25:5

7 PM

C:\U

sers

\NN

asis

\Doc

umen

ts\1

8120

00-A

_202

0_nn

asis

@bl

ta.c

om.rv

t

204 S 12TH STREET204 S 12TH STREETPHILADELPHIA, PA19107

1812000 3/23/2020

NPN BD

ZONING ROOF PLAN

Z-101

Z-10

1 ZO

NIN

G R

OO

F PL

AN 3

/23/

2020

Scale: 1/8" = 1'-0"B1 ROOF PLAN

ZONING SET 02 FEBRUARY 2020

ZONING DRAWING LIST

SHEETNUMBER SHEET NAME

Z-101 ZONING ROOF PLANZ-102 ZONING FLOOR PLANSZ-103 ZONING FLOOR PLANSZ-201 ZONING ELEVATIONSZ-202 ZONING ELEVATIONSZ-301 ZONING SECTIONS site photos

Page 7: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 6

view from camac and st james looking north

S C

AMAC

STR

EET

12TH

STR

EET

ST. JAMES STREET

CHANCELLOR STREET

A1

Z-202

AA4

Z-202

A4

Z-201

A1

Z-201

A1Z-301

PROPERTY LINE

33'-9" 81'-9"

9'-8" 115'-6"

EXISTING CAMAC BUILDING ROOF

EXISTING FRANKLIN BUILDING ROOF

MECHANICAL ROOFRESIDENTIAL AMENITY DECK

24'-1

"60

'-7"

6'-10" 72'-5" 115'-6" 12'-3"

8'-1" 24'-6" 82'-11"

6'-8

"0"

110'

-3"

6'-9

"

8'-1" 16'-8" 90'-9" 0" 12'-2"

T.O. ELEV. PENTHOUSE ROOF 425' - 0"

110'

-3"

T.O. AMENITY PARAPET 303' - 6"

T.O. AMENITY ROOF 300' - 0"

5'-0

"

GUARDRAIL

32'-5

"

T.O. MECHANICAL SCREEN 435' - 0"

36'-2

"37

'-0"

56'-5" 16'-0"

T.O. ROOF 42' - 0"

T.O. PARAPET 43' - 0"

T.O. MECHANICAL ROOM 410' - 0"

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

E

A

B

C

D

E

BLT A

RC

HITE

CTS 1216 A

RC

H S

TRE

ET S

UITE

800 PH

ILAD

ELP

HIA

PE

NN

SY

LVA

NIA

PH

ON

E 215.563.3900 FA

X 215.563.3036

PROJECT TITLE

CLIENT

CIVIL ENGINEER

STRUCTURAL ENGINEER

MEP / AV / IT ENGINEER

VERTICAL TRANSPORTATION

ACOUSTICAL

LIGHTING

SEAL

MIDWOOD INVESTMENT & DEVELOPMENT430 PARK AVENUE, 505NEW YORK, NY 10022

BOHLER ENGINEERING1515 MARKET STREETSUITE 920PHILADLEPHIA, PA 19102

WSP USAONE PENN PLAZA250 W 34TH STREETNEW YORK, NY 10119

BALA CONSULTING ENGINEERS443 SOUTH GULPH ROADKING OF PRUSSIA, PA 19406

VDA (VAN DUESEN & ASSOCIATES221 LAUREL ROADSUITE 130VOORHEES, NJ 08043

LONGMAN LINDSEY200 WEST 41ST STREET, SUITE 1100NEW YORK, NY 10036

THE LIGHTING PRACTICETHE PUBLIC LEDGER BUILDING600 CHESTNUT STREET, SUITE 772PHILADLEPHIA, PA 19106

PROJECT NO FIRST ISSUE DATE

FILE SCALE

REVIEWEDDRAWN BY

NO ISSUE NAME DATE

SHEET TITLE

SHEET NO

@C

OP

YR

IGH

T 20

16: B

LT A

RC

HIT

EC

TS

1/8" = 1'-0"

4/10

/202

0 2:

25:5

7 PM

C:\U

sers

\NN

asis

\Doc

umen

ts\1

8120

00-A

_202

0_nn

asis

@bl

ta.c

om.rv

t

204 S 12TH STREET204 S 12TH STREETPHILADELPHIA, PA19107

1812000 3/23/2020

NPN BD

ZONING ROOF PLAN

Z-101

Z-10

1 ZO

NIN

G R

OO

F PL

AN 3

/23/

2020

Scale: 1/8" = 1'-0"B1 ROOF PLAN

ZONING SET 02 FEBRUARY 2020

ZONING DRAWING LIST

SHEETNUMBER SHEET NAME

Z-101 ZONING ROOF PLANZ-102 ZONING FLOOR PLANSZ-103 ZONING FLOOR PLANSZ-201 ZONING ELEVATIONSZ-202 ZONING ELEVATIONSZ-301 ZONING SECTIONS

view from camac & st james looking east

site photos

Page 8: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 7

APPROX. LOC. UNDERGROUND TEL. LINE

APPROX. LOC. UNDERGROUND WATER LINE

REFERENCES:

1. MAP 004 N 07 OF THE OFFICIAL TAX REGISTRY OF THE CITY & COUNTY OF

PHILADELPHIA, COMMONWEALTH OF PENNSYLVANIA.

2. MAP ENTITLED "NATIONAL FLOOD INSURANCE PROGRAM, FIRM, FLOOD

INSURANCE RATE MAP,CITY OF PHILADELPHIA, PENNSYLVANIA, PHILADELPHIA

COUNTY, PANEL 184 OF 230", MAP NUMBER 420757 0184 H, MAP REVISED:

NOVEMBER 18, 2015.

3. MAP ENTITLED " CITY PLAN NO. 271A", PROVIDED BY THE CITY OF

PHILADELPHIA.

4. MAP ENTITLED "PLAN REVISING THE LINES AND GRADES ON CITY PLAN NO. 271

OF THE AREA BOUNDED BY FIFTH STREET, SPRING GARDEN STREET, SIXTH

STREET AND FAIRMOUNT AVENUE, BY WIDENING PORTIONS OF FIFTH STREET

AND SIXTH STREET, BY STRIKING FROM THE CITY PLAN AND VACATING GREEN

STREET, AND BY RESERVING AND PLACING ON THE CITY PLAN A CERTAIN

RIGHT OF WAY FOR WATER MAIN PURPOSES AND PUBLIC UTILITY PURPOSES,

UNDER CERTAIN TERMS AND CONDITIONS," PROVIDED BY THE CITY OF

PHILADELPHIA.

5. MAP ENTITLED "THE DECLARATION PLAN OF FIFTH STREET WHOLESALE

DISTRIBUTORS ASSOCIATION INC. FOR SPRING GARDEN STREET MALL PLAN OF

SUBDIVISION OF PROPERTY" PREPARED BY VINCENT NERO, SURVEYOR &

REGULATOR OF THE THIRD SURVEY DISTRICT, DATED JULY 16, 1964 AND LAST

REVISED OCTOBER 27, 1964.

6. STREET STATUS CARD ENTITLED "LC000266", "LC000320" & "LC003101", PROVIDE

BY THE CITY OF PHILADELPHIA.

7. MAPS ENTITLED "PWD #122358", "PWD #159827", "PWD #195098", "PWD #197305",

"PWD #252444", "PWD #261426" & "PWD #269711",PROVIDED BY THE

PHILADELPHIA WATER DEPARTMENT.

8. MAP SHOWING THE LOCATION OF UNDERGROUND GAS FACILITIES PROVIDED

BY PHILADELPHIA GAS WORKS.

9. MAPS SHOWING THE LOCATION OF UNDERGROUND TELECOMMUNICATIONS

FACILITIES PROVIDED BY VERIZON.

10. MAPS ENTITLED "5-N-5" & "6-N-5B", PROVIDED BY THE CITY OF PHILADELPHIA

BOARD OF HIGHWAY SUPERVISORS.

11. MAPS SHOWING THE LOCATION OF UNDERGROUND ELECTRIC FACILITIES

PROVIDED BY PECO.

APPROX. LOC. UNDERGROUND ELEC. LINEAPPROX. LOC. UNDERGROUND GAS LINEOVERHEAD WIRES

EXIST. GUTTER ELEVATION

EXISTING SPOT ELEVATION

EXIST. TOP OF WALL ELEVATION

EXIST. BOTTOM OF WALL ELEVATION

EXIST. TOP OF CURB ELEVATION

EXISTING CONTOUR

LEGEND

EXIST. FINISHED FLOOR ELEVATION

EXIST. DOOR SILL ELEVATION

PER R

EF. MAP #5

UTILITY COMPANY PHONE NUMBER

UTILITIES:

THE FOLLOWING COMPANIES WERE NOTIFIED BY PENNSYLVANIA ONE-CALL SYSTEM (1-800-242-1776) ANDREQUESTED TO MARK OUT UNDERGROUND FACILITIES AFFECTING AND SERVICING THIS SITE. THE UNDERGROUNDUTILITY INFORMATION SHOWN HEREON IS BASED UPON THE UTILITY COMPANIES RESPONSE TO THIS REQUEST.SERIAL NUMBER: 20183412105

DWG. NO.

C

200 & 204 SOUTH 12TH STREETBLTA

COMMONWEALTH OF PENNSYLVANIA

BOUNDARY & TOPOGRAPHIC SURVEY

79-77

P.V.

REVIEWED:

FIELD CREW

DRAWN:

G.N.

12-12-2018

CP18-17FIELD BOOK NO.

FIELD BOOK PG.

FIELD DATE

A

CITY & COUNTY OF PHILADELPHIA (5TH WARD)

SPL ORTNO

SS CO TAI ETNIO

NI, C .

OF 11D.K.H.APPROVED:

2-6-2019DATE

1"=10'SCALE

02-170305-01FILE NO.

REVISED PER ADDITIONAL UTILITIES1

No. DESCRIPTION OF REVISION

-- M.C.B. B.A.R. 4-16-2020

DATEAPPROVED:DRAWN:FIELD CREW

THE

CO

PYIN

G O

R R

EUSE

OF

THIS

DO

CU

MEN

T, O

R P

OR

TIO

NS

THER

EOF,

FO

R O

THER

TH

AN T

HE

OR

IGIN

AL P

RO

JEC

T O

R

THE

PUR

POSE

OR

IGIN

ALLY

INTE

ND

ED, W

ITH

OU

T TH

E W

RIT

TEN

PER

MIS

SIO

N O

F C

ON

TRO

L PO

INT

ASSO

CIA

TES,

INC

., IS

PR

OH

IBIT

ED.

CO

NTR

OL

POIN

T AS

SOC

IATE

S, IN

C.-

ALL

RIG

HTS

RES

ERVE

D.

DATE

NOT TO SCALE

THIS SURVEY HAS BEEN PERFORMED IN THE FIELD UNDER MY SUPERVISION, AND TO THE BEST OF MYKNOWLEDGE, BELIEF, AND INFORMATION, THAT THIS SURVEY HAS BEEN PERFORMED IN ACCORDANCE WITHCURRENTLY ACCEPTED ACCURACY STANDARDS.

NOT VALID UNLESS SEALED IN RED INK

PENNSYLVANIA PROFESSIONAL LAND SURVEYOR #SU075250JAMES C. WEED

NEW BRITAIN CORPORATE CENTER1600 MANOR DRIVE, SUITE 210CHALFONT, PA 18914215.712.9800 - 215.712.9802 FAXWWW.CPASURVEY.COM

VICINITY MAP

0 5 10 20 40

( IN FEET )1 inch = 10 ft.

GRAPHIC SCALE10

WARREN, NJ 908.668.0099

SOUTHBOROUGH, MA 508.948.3000

MT. LAUREL, NJ 609.857.2099MANHATTAN, NY 646.780.0411

LONG ISLAND, NY 631.580.2645

CLEAN OUT

APPROX. LOC. UNDERGROUND ELEC. LINE

APPROX. LOC. UNDERGROUND GAS LINE

GAS VALVE

WATER VALVE

AIR CONDITIONU-BOLLARD

BOLLARDSIGNUTILITY POLE

DECIDUOUS TREE & TRUNK SIZE

DRAINAGE/STORM MANHOLE

METAL COVER

TYPICAL

CATCH BASIN OR INLET

EXIST. GUTTER ELEVATION

EXISTING SPOT ELEVATION

EXIST. TOP OF WALL ELEVATION

EXIST. BOTTOM OF WALL ELEVATION

EXIST. TOP OF CURB ELEVATION

EXISTING CONTOUR

LEGEND

EXIST. FINISHED FLOOR ELEVATION

EXIST. DOOR SILL ELEVATION

DETECTABLE WARNING PADHEIGHT BUILDING NO VISIBLE PIPE

APPROX. LOC. UNDERGROUND WATER LINE CROWN CASLTEAT & T

COMCAST CABLEVISIONLIGHTOWER

INTERSECTION MEDIAPECO

LEVEL 3MCI

PHILADELPHIA CITY WATER DEPTZAYO BANDWIDTH

PHILADELPHIA DEPT OF STREETSPHILADELPHIA GAS WORKS

SEPTAVEOLIA ENERGY PHILADELPHIA, INC (TRIGEN)

VERIZON

215-951-2700800-222-0400215-961-3800703-434-8500215-693-3991610-943-5522720-888-0165800-888-0800215-685-6300610-774-5151215-686-5503215-978-3000215-580-7852215-875-6900215-963-6000

NOTES:1. PROPERTY KNOWN AS MAP 2 S 15, PARCEL 65, OPA 88-1009416 & PARCELS 35, 50, 115, 116, 217, 247 &

248, OPA 88-2568700 AS IDENTIFIED ON THE TAX REGISTRY OF THE CITY & COUNTY OF PHILADELPHIA,COMMONWEALTH OF PENNSYLVANIA.

2. AREA (PARCEL 35) (P.D.S.) = 1,340.4 S.F. OR 0.03077 AC.AREA (PARCEL 35) (U.S.S.) = 1,347.1 S.F. OR 0.03092 AC.

AREA (PARCEL 50) (P.D.S.) = 1,800.0 S.F. OR 0.04132 AC.AREA (PARCEL 50) (U.S.S.) = 1,809.0 S.F. OR 0.04153 AC.

AREA (PARCEL 65) (P.D.S.) = 1,482.0 S.F. OR 0.03402 AC.AREA (PARCEL 65) (U.S.S.) = 1,489.4 S.F. OR 0.03419 AC.

AREA (PARCEL 115) (P.D.S.) = 1,737.0 S.F. OR 0.03988 AC.AREA (PARCEL 115) (U.S.S.) = 1,745.7 S.F. OR 0.04008 AC.

AREA (PARCEL 116) (P.D.S.) = 1,349.0 S.F. OR 0.03097 AC.AREA (PARCEL 116) (U.S.S.) = 1,355.7 S.F. OR 0.03112 AC.

AREA (PARCEL 217) (P.D.S.) = 5,351.0 S.F. OR 0.12284 AC.AREA (PARCEL 217) (U.S.S.) = 5,377.8 S.F. OR 0.12346 AC.

AREA (PARCEL 247) (P.D.S.) = 2,605.5 S.F. OR 0.05981 AC.AREA (PARCEL 247) (U.S.S.) = 2,618.5 S.F. OR 0.06011 AC.

AREA (PARCEL 248) (P.D.S.) = 2,677.9 S.F. OR 0.06148 AC.AREA (PARCEL 248) (U.S.S.) = 2,691.3 S.F. OR 0.06178 AC.

AREA (OVERALL) (P.D.S.) = 18,342.6 S.F. OR 0.42109 AC.AREA (OVERALL) (U.S.S.) = 18,434.4 S.F. OR 0.42320 AC.

3. LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE. LOCATIONS AND SIZES ARE BASED ONUTILITY MARK-OUTS, ABOVE GROUND STRUCTURES THAT WERE VISIBLE & ACCESSIBLE IN THE FIELD,AND THE MAPS AS LISTED IN THE REFERENCES AVAILABLE AT THE TIME OF THE SURVEY. AVAILABLEAS-BUILT PLANS AND UTILITY MARKOUT DOES NOT ENSURE MAPPING OF ALL UNDERGROUNDUTILITIES AND STRUCTURES. BEFORE ANY EXCAVATION IS TO BEGIN, ALL UNDERGROUND UTILITIESSHOULD BE VERIFIED AS TO THEIR LOCATION, SIZE AND TYPE BY THE PROPER UTILITY COMPANIES.CONTROL POINT ASSOCIATES, INC. DOES NOT GUARANTEE THE UTILITIES SHOWN COMPRISE ALLSUCH UTILITIES IN THE AREA EITHER IN SERVICE OR ABANDONED.

4. THIS PLAN IS BASED ON INFORMATION PROVIDED BY A SURVEY PREPARED IN THE FIELD BY CONTROLPOINT ASSOCIATES, INC. AND OTHER REFERENCE MATERIAL AS LISTED HEREON.

5. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT AND IS SUBJECT TO THERESTRICTIONS, COVENANTS AND/OR EASEMENTS THAT MAY BE CONTAINED THEREIN.

6. THE EXISTENCE OF UNDERGROUND STORAGE TANKS, IF ANY, WAS NOT KNOWN AT THE TIME OF THEFIELD SURVEY.

7. ELEVATIONS ARE BASED UPON PHILADELPHIA CITY PLAN DATUM. BASED ON THE PI AT THESOUTHWEST CORNER OF CHANCELLOR STREET AND 12TH STREET. (PER REF. MAP #3)

TEMPORARY BENCH MARKS SET:

TBM-1: MAG NAIL SET IN ASPHALTELEV. = 32.97

TBM-2: MAG NAIL SET IN CONCRETEELEV. = 33.78

PRIOR TO CONSTRUCTION IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT THEBENCHMARKS ILLUSTRATED ON THIS SKETCH HAVE NOT BEEN DISTURBED AND THEIR ELEVATIONSHAVE BEEN CONFIRMED. ANY CONFLICTS MUST BE REPORTED PRIOR TO CONSTRUCTION.

8. BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS LOCATED IN FLOOD HAZARD ZONE X (AREASDETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN PER REF. MAP #2.

9. UNDERGROUND STORM SEWER AND SANITARY SEWER PIPES ARE DRAWN GRAPHICALLY ON THISSURVEY AND SHOULD BE CONSIDERED APPROXIMATE. UNDERGROUND STORM AND SANITARY PIPESSHOULD BE VERIFIED INDEPENDENTLY AS TO THEIR LOCATION, SIZE AND TYPE BY THE CONTRACTOROR DESIGN CONSULTANT PRIOR TO CONSTRUCTION.

10. THIS SURVEY IS PREPARED TO UNITED STATES STANDARD (U.S.S.), OTHER DISTANCES SHOWN ARE INPHILADELPHIA DISTRICT STANDARD AND ARE MARKED (P.D.S.).

11. ENCROACHMENTS AND VAULTS, IF ANY, BELOW SURFACE NOT SHOWN HEREON.

12. THE CONVERSION FROM INCHES TO THE MORE PRECISE DECIMAL EXPRESSION MAY RESULT IN MINORCHANGES IN THE SECOND AND THIRD DECIMAL PLACES, THESE ARE NOT ERRORS OR OVERSIGHTSBUT MORE PRECISE VALUES.

13. ATTENTION IS CALLED TO THE ZONING REQUIREMENTS IN THE PHILADELPHIA CODE AS AMENDED.

14. PLAN IS MADE PER INSTRUCTION OF BLTA.

15. BUILDING DIMENSIONS SHOWN HEREON ARE MEASURED AT GROUND LEVEL OF BUILDING EXTERIOR.

REFERENCES:1. MAP 2 S 15 OF THE OFFICIAL TAX REGISTRY OF THE CITY & COUNTY OF PHILADELPHIA,

COMMONWEALTH OF PENNSYLVANIA.

2. MAP ENTITLED "NATIONAL FLOOD INSURANCE PROGRAM, FIRM, FLOOD INSURANCE RATE MAP, CITY OFPHILADELPHIA, PENNSYLVANIA, PHILADELPHIA COUNTY, PANEL 183 OF 230", MAP NUMBER 420757 0183G, MAP REVISED: JANUARY 17, 2007.

3. MAP ENTITLED "COMPILATION OF A PORTION OF CITY PLAN NO. 308", PROVIDED BY THE CITY OFPHILADELPHIA.

4. MAPS ENTITLED "LC000674", "LC006643", "LC007107" & "LC012749", PROVIDED BY THE CITY OFPHILADELPHIA.

5. MAP ENTITLED "12-S-2A" ,PROVIDED BY THE CITY OF PHILADELPHIA BOARD OF HIGHWAYSUPERVISORS.

6. MAP ENTITLED "PWD#102507", "PWD#103789", "PWD#103792", "PWD#105919", "PWD#122967","PWD#148184", "PWD#400188", PWD#400560, "PWD#401169", "PWD#400189" & "PWD#400568", PROVIDEDBY THE PHILADELPHIA WATER DEPARTMENT.

7. MAPS SHOWING THE LOCATION OF UNDERGROUND STEAM FACILITIES PROVIDED BY VEOLIA.

8. MAPS SHOWING THE LOCATION OF UNDERGROUND TELECOMMUNICATIONS FACILITIES PROVIDED BYVERIZON.

9. MAP ENTITLED "ALTA/NSPS LAND TITLE SURVEY, PHILADELPHIA BUILDINGS 200, 202, 204, & 206-208SOUTH 12TH STREET, 201 SOUTH CAMAC STREET, 1209 ST. JAMES STREET AND 1210 CHANCELLORSTREET", PREPARED BY FIRST ORDER, LLC, DRAWING NO. 5698, DATED 10-6-2017, LAST REVISED10-13-2017.

10. MAP ENTITLED "N5-11", PREPARED BY THE PHILADELPHIA GAS WORKS, DATED 12-13-2018.

OVERHEAD WIRES

APPROX. LOC. UNDERGROUND TEL. LINE

DEPRESSED CURB

6-26-2020

SITE

LIGHT LAMP

UNABLE TO OPEN

PHILADELPHIA DISTRICT STANDARDUNITED STATES STANDARDSURVEY MEASUREMENTDEED MEASUREMENT

APPROX. LOC. UNDERGROUND STEAM LINE

REVISED PER CLIENT COMMENTS2 -- B.L.M. B.A.R. 6-26-2020

existing site plan

UTILITY COMPANY PHONE NUMBER

UTILITIES:

THE FOLLOWING COMPANIES WERE NOTIFIED BY PENNSYLVANIA ONE-CALL SYSTEM (1-800-242-1776) ANDREQUESTED TO MARK OUT UNDERGROUND FACILITIES AFFECTING AND SERVICING THIS SITE. THE UNDERGROUNDUTILITY INFORMATION SHOWN HEREON IS BASED UPON THE UTILITY COMPANIES RESPONSE TO THIS REQUEST.SERIAL NUMBER: 20183412105

THE

CO

PYIN

G O

R R

EUSE

OF

THIS

DO

CU

MEN

T, O

R P

OR

TIO

NS

THER

EOF,

FO

R O

THER

TH

AN T

HE

OR

IGIN

AL P

RO

JEC

T O

R

THE

PUR

POSE

OR

IGIN

ALLY

INTE

ND

ED, W

ITH

OU

T TH

E W

RIT

TEN

PER

MIS

SIO

N O

F C

ON

TRO

L PO

INT

ASSO

CIA

TES,

INC

., IS

PR

OH

IBIT

ED.

CO

NTR

OL

POIN

T AS

SOC

IATE

S, IN

C.-

ALL

RIG

HTS

RES

ERVE

D.

THIS SURVEY KNOWLEDGE,CURRENTLY A

PENNSYLVANJAMES

0 5 10 20 40

( IN FEET )1 inch = 10 ft.

GRAPHIC SCALE10

CLEAN OUT

APPROX. LOC. UNDERGROUND ELEC. LINE

APPROX. LOC. UNDERGROUND GAS LINE

GAS VALVE

WATER VALVE

AIR CONDITIONU-BOLLARD

BOLLARDSIGNUTILITY POLE

DECIDUOUS TREE & TRUNK SIZE

DRAINAGE/STORM MANHOLE

METAL COVER

TYPICAL

CATCH BASIN OR INLET

EXIST. GUTTER ELEVATION

EXISTING SPOT ELEVATION

EXIST. TOP OF WALL ELEVATION

EXIST. BOTTOM OF WALL ELEVATION

EXIST. TOP OF CURB ELEVATION

EXISTING CONTOUR

LEGEND

EXIST. FINISHED FLOOR ELEVATION

EXIST. DOOR SILL ELEVATION

DETECTABLE WARNING PADHEIGHT BUILDING NO VISIBLE PIPE

APPROX. LOC. UNDERGROUND WATER LINE CROWN CASLTEAT & T

COMCAST CABLEVISIONLIGHTOWER

INTERSECTION MEDIAPECO

LEVEL 3MCI

PHILADELPHIA CITY WATER DEPTZAYO BANDWIDTH

PHILADELPHIA DEPT OF STREETSPHILADELPHIA GAS WORKS

SEPTAVEOLIA ENERGY PHILADELPHIA, INC (TRIGEN)

VERIZON

215-951-2700800-222-0400215-961-3800703-434-8500215-693-3991610-943-5522720-888-0165800-888-0800215-685-6300610-774-5151215-686-5503215-978-3000215-580-7852215-875-6900215-963-6000

OVERHEAD WIRES

APPROX. LOC. UNDERGROUND TEL. LINE

DEPRESSED CURB

LIGHT LAMP

UNABLE TO OPEN

PHILADELPHIA DISTRICT STANDARDUNITED STATES STANDARDSURVEY MEASUREMENTDEED MEASUREMENT

APPROX. LOC. UNDERGROUND STEAM LINE

note: office of property assessment addresses include 200 south 12th street and 204 south 12th street

Page 9: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 8

RESIDENTIAL PEDESTRIAN ACCESS

VEHICULAR ACCESS

RETAIL PEDESTRIAN ACCESS

ta

dickenson

10’ 20’0’ 40’

site and landscape plan

existing building

Page 10: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

0’ 20’ 40’ 80’

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 9

below grade parking level 02below grade parking level 03

ta

dickenson

below grade parking level 01

floor plans

UPUP

UP

23 SPACES

189 BIKE STORAGE

C C

TYP.

8'-4

"

18'-0" TYP.25'-2"

18'-2

"

37'-4"

PARKING 14,943 SF

60.00°

8'-6" TYP.

18'-0

" TYP

.

CC

8'-0" TYP.

16'-0

" TYP

.

60.00°

8'-0" TYP.

16'-0

" TYP

.

60.00°

ELEVATOR

20'-0

"

8'-6"

PARKING ELEVATOR

9'-0"

TYP

.

18'-0" TYP.

60.00°

20'-8"

25'-2"

FPR INCOMIING SERVICES

16'-3"

204 S 12TH STREETParking Plans

UPUP

UP

UPUP

UP

UP

22 SPACES

C C

18'-0" TYP. 25'-2"

18'-2

"

37'-1"

PARKING 12,955 SF

8'-0

"

TYP.

9'-0

"

18'-0" TYP.

60.00°

8'-6" TYP.

18'-0

" TYP

.

VAN

CC

8'-0" TYP.

16'-0

" TYP

.

60.00°

8'-0" TYP.

16'-0

" TYP

.

60.00°

ELEVATOR

20'-0

"

8'-6"

PARKING ELEVATOR

60.00°

EXISTING CAMAC

BUILDING

20'-8"

25'-2"

TYP.

8'-6

"OPEN TO BELOW

16'-3"

23 SPACES

189 BIKE STORAGE

37'-4"

PARKING ELEVATOR

" TYP

.

20'-8" 16'-3"

23 SPACES

CC

PP

P

TYP.

8'-6

"

18'-0" TYP. 25'-2"

37'-4"

60.00°

8'-6" TYP.

18'-0

" TYP

.

C

18'-2

"

18'-0"

8'-0" TYP.

16'-0

" TYP

.

60.00°

8'-0" TYP.

16'-0

" TYP

. C

60.00°

16'-3"

20'-0

"

8'-6"

PARKING ELEVATOR

20'-8"

25'-2" 9'-0"

TYP

.

18'-0" TYP.

P

UP

23 SPACES

CC

PP

P

TYP.

8'-6

"

18'-0" TYP. 25'-2"

37'-4"

PARKING 13,482 SF

60.00°

8'-6" TYP.

18'-0

" TYP

.

C

18'-2

"

18'-0"

8'-0" TYP.

16'-0

" TYP

.

60.00°

8'-0" TYP.

16'-0

" TYP

. C

60.00°

16'-3"

ELEVATOR

20'-0

"

8'-6"

PARKING ELEVATOR

20'-8"

25'-2" 9'-0"

TYP

.

18'-0" TYP.

P

Page 11: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

0’ 20’ 40’ 80’

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 10

level 02

ta

dickenson

EXISTING CAMAC BUILDING

FRANKLIN CLUB

ground level

EXISTING CAMAC BUILDING

FRANKLIN CLUB

1

2

3

floor plans

RETAIL

SERVICE RESIDENTIAL

RESIDENTIAL BOH ELEVATOR

Page 12: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 11

typical level (4-16)level 03

RETAIL

SERVICE RESIDENTIAL

RESIDENTIAL NIT

floor plans

ELEVATOR

Page 13: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 12floor plans

amenities level 27typical level (17-26)

RESIDENTIAL

SERVICE RESIDENTIAL UNIT

AMENITY ELEVATOR

residential

amenity

terrace

Page 14: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 13

penthouse level (28-31)

ta

dickenson

0’ 20’ 40’ 80’

floor plans

RESIDENTIAL

RESIDENTIAL UNIT SERVICE

ELEVATOR

Page 15: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 14massing in context

Page 16: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

ta

dickenson

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 15

site section - east - west

S C

AMAC

STR

EET

12TH

STR

EET

ST. JAMES STREET

CHANCELLOR STREET

A1

Z-202

AA4

Z-202

A4

Z-201

A1

Z-201

A1Z-301

PROPERTY LINE

33'-9" 81'-9"

9'-8" 115'-6"

EXISTING CAMAC BUILDING ROOF

EXISTING FRANKLIN BUILDING ROOF

MECHANICAL ROOFRESIDENTIAL AMENITY DECK

24'-1

"60

'-7"

6'-10" 72'-5" 115'-6" 12'-3"

8'-1" 24'-6" 82'-11"

6'-8

"0"

110'

-3"

6'-9

"

8'-1" 16'-8" 90'-9" 0" 12'-2"

T.O. ELEV. PENTHOUSE ROOF 425' - 0"

110'

-3"

T.O. AMENITY PARAPET 303' - 6"

T.O. AMENITY ROOF 300' - 0"

5'-0

"

GUARDRAIL

32'-5

"

T.O. MECHANICAL SCREEN 435' - 0"

36'-2

"37

'-0"

56'-5" 16'-0"

T.O. ROOF 42' - 0"

T.O. PARAPET 43' - 0"

T.O. MECHANICAL ROOM 410' - 0"

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

E

A

B

C

D

EPROJECT

CLIENT

CIVIL ENG

STRUCTU

MEP / AV

VERTICAL

ACOUSTI

LIGHTING

SEAL

MD43N

B15SUP

WO25N

B44K

V22SUV

L2011N

TT60P

PROJECT

FILE

DRAWN B

NO IS

SHEET TI

SHEET N

@C

OP

YR

IGH

T 20

16: B

LT A

RC

HIT

EC

TS

4/10

/202

0 2:

25:5

7 PM

C:\U

sers

\NN

asis

\Doc

umen

ts\1

8120

00-A

_202

0_nn

asis

@bl

ta.c

om.rv

t

22P1

181200

NPN

ZONIN

Z-10

1 ZO

NIN

G R

OO

F PL

AN 3

/23/

2020

Scale: 1/8" = 1'-0"B1 ROOF PLAN

ZO

ZONING DRAWING LIST

SHEETNUMBER SHEET NAME

Z-101 ZONING ROOF PLANZ-102 ZONING FLOOR PLANSZ-103 ZONING FLOOR PLANSZ-201 ZONING ELEVATIONSZ-202 ZONING ELEVATIONSZ-301 ZONING SECTIONS

0’ 20’ 40’ 80’

building sections

RETAIL

RESIDENTIAL UNITS

AMENITY

SERVICE

PARKING

RESIDENTIAL

Page 17: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 16

elevation - east

S C

AMAC

STR

EET

12TH

STR

EET

ST. JAMES STREET

CHANCELLOR STREET

A1

Z-202

AA4

Z-202

A4

Z-201

A1

Z-201

A1Z-301

PROPERTY LINE

33'-9" 81'-9"

9'-8" 115'-6"

EXISTING CAMAC BUILDING ROOF

EXISTING FRANKLIN BUILDING ROOF

MECHANICAL ROOFRESIDENTIAL AMENITY DECK

24'-1

"60

'-7"

6'-10" 72'-5" 115'-6" 12'-3"

8'-1" 24'-6" 82'-11"

6'-8

"0"

110'

-3"

6'-9

"

8'-1" 16'-8" 90'-9" 0" 12'-2"

T.O. ELEV. PENTHOUSE ROOF 425' - 0"

110'

-3"

T.O. AMENITY PARAPET 303' - 6"

T.O. AMENITY ROOF 300' - 0"

5'-0

"

GUARDRAIL

32'-5

"

T.O. MECHANICAL SCREEN 435' - 0"

36'-2

"37

'-0"

56'-5" 16'-0"

T.O. ROOF 42' - 0"

T.O. PARAPET 43' - 0"

T.O. MECHANICAL ROOM 410' - 0"

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

E

A

B

C

D

EPROJECT

CLIENT

CIVIL ENG

STRUCTU

MEP / AV

VERTICAL

ACOUSTI

LIGHTING

SEAL

MD43N

B15SUP

WO25N

B44K

V22SUV

L2011N

TT60P

PROJECT

FILE

DRAWN B

NO IS

SHEET TI

SHEET N

@C

OP

YR

IGH

T 20

16: B

LT A

RC

HIT

EC

TS

4/10

/202

0 2:

25:5

7 PM

C:\U

sers

\NN

asis

\Doc

umen

ts\1

8120

00-A

_202

0_nn

asis

@bl

ta.c

om.rv

t

22P1

181200

NPN

ZONIN

Z-10

1 ZO

NIN

G R

OO

F PL

AN 3

/23/

2020

Scale: 1/8" = 1'-0"B1 ROOF PLAN

ZO

ZONING DRAWING LIST

SHEETNUMBER SHEET NAME

Z-101 ZONING ROOF PLANZ-102 ZONING FLOOR PLANSZ-103 ZONING FLOOR PLANSZ-201 ZONING ELEVATIONSZ-202 ZONING ELEVATIONSZ-301 ZONING SECTIONS

ta

dickenson

0’ 20’ 40’ 80’

building elevations

Page 18: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 17

elevation - west

S C

AMAC

STR

EET

12TH

STR

EET

ST. JAMES STREET

CHANCELLOR STREET

A1

Z-202

AA4

Z-202

A4

Z-201

A1

Z-201

A1Z-301

PROPERTY LINE

33'-9" 81'-9"

9'-8" 115'-6"

EXISTING CAMAC BUILDING ROOF

EXISTING FRANKLIN BUILDING ROOF

MECHANICAL ROOFRESIDENTIAL AMENITY DECK

24'-1

"60

'-7"

6'-10" 72'-5" 115'-6" 12'-3"

8'-1" 24'-6" 82'-11"

6'-8

"0"

110'

-3"

6'-9

"

8'-1" 16'-8" 90'-9" 0" 12'-2"

T.O. ELEV. PENTHOUSE ROOF 425' - 0"

110'

-3"

T.O. AMENITY PARAPET 303' - 6"

T.O. AMENITY ROOF 300' - 0"

5'-0

"

GUARDRAIL

32'-5

"

T.O. MECHANICAL SCREEN 435' - 0"

36'-2

"37

'-0"

56'-5" 16'-0"

T.O. ROOF 42' - 0"

T.O. PARAPET 43' - 0"

T.O. MECHANICAL ROOM 410' - 0"

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

E

A

B

C

D

EPROJECT

CLIENT

CIVIL ENG

STRUCTU

MEP / AV

VERTICAL

ACOUSTI

LIGHTING

SEAL

MD43N

B15SUP

WO25N

B44K

V22SUV

L2011N

TT60P

PROJECT

FILE

DRAWN B

NO IS

SHEET TI

SHEET N

@C

OP

YR

IGH

T 20

16: B

LT A

RC

HIT

EC

TS

4/10

/202

0 2:

25:5

7 PM

C:\U

sers

\NN

asis

\Doc

umen

ts\1

8120

00-A

_202

0_nn

asis

@bl

ta.c

om.rv

t

22P1

181200

NPN

ZONIN

Z-10

1 ZO

NIN

G R

OO

F PL

AN 3

/23/

2020

Scale: 1/8" = 1'-0"B1 ROOF PLAN

ZO

ZONING DRAWING LIST

SHEETNUMBER SHEET NAME

Z-101 ZONING ROOF PLANZ-102 ZONING FLOOR PLANSZ-103 ZONING FLOOR PLANSZ-201 ZONING ELEVATIONSZ-202 ZONING ELEVATIONSZ-301 ZONING SECTIONS

elevation - north

ta

dickenson

0’ 40’ 80’ 160’elevation - south

building elevations

Page 19: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 18aerial view from 12th street

Page 20: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 19view along 12th street looking north

Page 21: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 20view along 12th street looking south

Page 22: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 21contemplated material palette

grc

shadow box wood panel

louver

vision glass

Page 23: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 22

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

1

INSTRUCTIONS This Checklist is an implementation tool of the Philadelphia Complete Streets Handbook (the “Handbook”) and enables City engineers and planners to review projects for their compliance with the Handbook’s policies. The handbook provides design guidance and does not supersede or replace language, standards or policies established in the City Code, City Plan, or Manual on Uniform Traffic Control Devices (MUTCD).

The Philadelphia City Planning Commission receives this Checklist as a function of its Civic Design Review (CDR) process. This checklist is used to document how project applicants considered and accommodated the needs of all users of city streets and sidewalks during the planning and/or design of projects affecting public rights-of-way. Departmental reviewers will use this checklist to confirm that submitted designs incorporate complete streets considerations (see §11-901 of The Philadelphia Code). Applicants for projects that require Civic Design Review shall complete this checklist and attach it to plans submitted to the Philadelphia City Planning Commission for review, along with an electronic version.

The Handbook and the checklist can be accessed at http://www.phila.gov/CityPlanning/projectreviews/Pages/CivicDesignReview.aspx

PRELIMINARY PCPC REVIEW AND COMMENT: CSM

DATE 07/13/20

FINAL STREETS DEPT REVIEW AND COMMENT:

DATE

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

2

INSTRUCTIONS (continued) APPLICANTS SHOULD MAKE SURE TO COMPLY WITH THE FOLLOWING REQUIREMENTS:

This checklist is designed to be filled out electronically in Microsoft Word format. Please submit the Word version of the checklist. Text fields will expand automatically as you type.

All plans submitted for review must clearly dimension the widths of the Furnishing, Walking, and Building Zones (as defined in Section 1 of the Handbook). “High Priority” Complete Streets treatments (identified in Table 1 and subsequent sections of the Handbook) should be identified and dimensioned on plans.

All plans submitted for review must clearly identify and site all street furniture, including but not limited to bus shelters, street signs and hydrants.

Any project that calls for the development and installation of medians, bio-swales and other such features in the right-of-way may require a maintenance agreement with the Streets Department.

ADA curb-ramp designs must be submitted to Streets Department for review

Any project that significantly changes the curb line may require a City Plan Action. The City Plan Action Application is available at http://www.philadelphiastreets.com/survey-and-design-bureau/city-plans-unit . An application to the Streets Department for a City Plan Action is required when a project plan proposes the:

o Placing of a new street; o Removal of an existing street; o Changes to roadway grades, curb lines, or widths; or o Placing or striking a city utility right-of-way.

Complete Streets Review Submission Requirement*:

• EXISTING CONDITIONS SITE PLAN, should be at an identified standard engineering scale o FULLY DIMENSIONED o CURB CUTS/DRIVEWAYS/LAYBY LANES o TREE PITS/LANDSCAPING o BICYCLE RACKS/STATIONS/STORAGE AREAS o TRANSIT SHELTERS/STAIRWAYS

• PROPOSED CONDITIONS SITE PLAN, should be at an identified standard engineering scale o FULLY DIMENSIONED, INCLUDING DELINEATION OF WALKING, FURNISHING, AND BUILDING ZONES AND

PINCH POINTS o PROPOSED CURB CUTS/DRIVEWAYS/LAYBY LANES o PROPOSED TREE PITS/LANDSCAPING o BICYCLE RACKS/STATIONS/STORAGE AREAS o TRANSIT SHELTERS/STAIRWAYS

*APPLICANTS PLEASE NOTE: ONLY FULL-SIZE, READABLE SITE PLANS WILL BE ACCEPTED. ADDITIONAL PLANS MAY BE REQUIRED AND WILL BE REQUESTED IF NECESSARY

complete streets handbook checklist

Page 24: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 23

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

3

GENERAL PROJECT INFORMATION 1. PROJECT NAME

200-204 S. 12th Street Proposed Mixed-Use Development 2. DATE

07/14/2020 3. APPLICANT NAME

South 12th Street Owner LLC 4. APPLICANT CONTACT INFORMATION

430 Park Avenue, New York, NY, Suite 201 Phone: (917)-658-9053 Email: [email protected]

5. PROJECT AREA: list precise street limits and scope South 12th Street South Camac Street Chancellor Street St. James Street 15,869 SF

6. OWNER NAME South 12th Street Owner LLC

7. OWNER CONTACT INFORMATION 430 Park Avenue, New York, NY, Suite 201 Phone: (917)-658-9053 Email: [email protected]

8. ENGINEER / ARCHITECT NAME Bohler Engineer

9. ENGINEER / ARCHITECT CONTACT INFORMATION 1515 Market Street, Suite 920, Philadelphia, PA 19102 Phone: (267) 402-3400 Email: [email protected]

10. STREETS: List the streets associated with the project. Complete Streets Types can be found at www.phila.gov/map under the “Complete Street Types” field. Complete Streets Types are also identified in Section 3 of the Handbook. Also available here: http://metadata.phila.gov/#home/datasetdetails/5543867320583086178c4f34/

STREET FROM TO COMPLETE STREET TYPE South 12th Street St. James Street Chancellor Street City Neighborhood Street South Camac Street St. James Street Chancellor Street Shared Narrow Chancellor Street South Camac Street South 12th Street Shared Narrow St. James Street South Camac Street South 12th Street Local

11. Does the Existing Conditions site survey clearly identify the following existing conditions with dimensions? a. Parking and loading regulations in curb lanes adjacent to the site YES NO b. Street Furniture such as bus shelters, honor boxes, etc. YES NO N/A c. Street Direction YES NO d. Curb Cuts YES NO N/A e. Utilities, including tree grates, vault covers, manholes, junction

boxes, signs, lights, poles, etc. YES NO N/A

f. Building Extensions into the sidewalk, such as stairs and stoops YES NO N/A

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

5

PEDESTRIAN COMPONENT (Handbook Section 4.3) 12. SIDEWALK: list Sidewalk widths for each street frontage. Required Sidewalk widths are listed in Section 4.3 of the

Handbook. STREET FRONTAGE TYPICAL SIDEWALK WIDTH

(BUILDING LINE TO CURB) Required / Existing / Proposed

CITY PLAN SIDEWALK WIDTH Existing / Proposed

St. James Street 10’ / 6.7’ / 6.7’ 6.75’ / 6.75’ South Camac Street N/A / 6.5’ / 6.5’ 6.75’ / 6.75’ South 12th Street Chancellor Street

12’/ 12.3’ / 12.3’ N/A/7.1’/7.1’

12’ / 12’ 6.75’/6.75’

13. WALKING ZONE: list Walking Zone widths for each street frontage. The Walking Zone is defined in Section 4.3 of the

Handbook, including required widths. STREET FRONTAGE WALKING ZONE

Required / Existing / Proposed St. James Street 5’ / 3.1’ / 4’ South Camac Street 5’ /4.1’/ 6.5’ South 12th Street Chancellor Street

6’ / 3.8’ / 8.2’ 5’/4’/4’

14. VEHICULAR INTRUSIONS: list Vehicular Intrusions into the sidewalk. Examples include but are not limited to; driveways, lay-by lanes, etc. Driveways and lay-by lanes are addressed in sections 4.8.1 and 4.6.3, respectively, of the Handbook. EXISTING VEHICULAR INTRUSIONS

INTRUSION TYPE INTRUSION WIDTH PLACEMENT N/A

PROPOSED VEHICULAR INTRUSIONS INTRUSION TYPE INTRUSION WIDTH PLACEMENT Curb Cut 16.7’ St. James Street Curb Cut 24’ Chancellor Street Curb Cut 22.1’ 12th Street

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

APPLICANT: General Project Information Additional Explanation / Comments: The project proposes a 32-story (448 units) multi-family building with underground parking and retail on lower levels. The site has frontage along South 12th Street, St. James Street, South Camac Street, and Chancellor Street.

DEPARTMENTAL REVIEW: General Project Information

complete streets handbook checklist

Page 25: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 24

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

7

BUILDING & FURNISHING COMPONENT (Handbook Section 4.4) 16. BUILDING ZONE: list the MAXIMUM, existing and proposed Building Zone width on each street frontage. The Building

Zone is defined as the area of the sidewalk immediately adjacent to the building face, wall, or fence marking the property line, or a lawn in lower density residential neighborhoods. The Building Zone is further defined in section 4.4.1 of the Handbook.

STREET FRONTAGE MAXIMUM BUILDING ZONE WIDTH Existing / Proposed

St. James Street 0 / 0 Chancellor Street 1.3 / 0 South 12th Street 4.1 / 0 South Camac Street 0.9 / 0

17. FURNISHING ZONE: list the MINIMUM, recommended, existing, and proposed Furnishing Zone widths on each street frontage. The Furnishing Zone is further defined in section 4.4.2 of the Handbook.

STREET FRONTAGE MINIMUM FURNISHING ZONE WIDTH Recommended / Existing / Proposed

St. James Street 3.5’ / 3.6’ / 2.8’ Chancellor Street N/A / 3.1’ / 2.8’ South 12th Street South Camac Street

6’ /8.5’/ 4’ N/A’/2.4’/0’

18. Identify proposed “high priority” building and furnishing zone design treatments that are incorporated into the design plan, where width permits (see Handbook Table 1). Are the following treatments identified and dimensioned on the plan?

DEPARTMENTAL APPROVAL

▪ Bicycle Parking YES NO N/A YES NO ▪ Lighting YES NO N/A YES NO ▪ Benches YES NO N/A YES NO ▪ Street Trees YES NO N/A YES NO ▪ Street Furniture YES NO N/A YES NO

19. Does the design avoid tripping hazards? YES NO N/A YES NO

20. Does the design avoid pinch points? Pinch points are locations where the Walking Zone width is less than the required width identified in item 13, or requires an exception

YES NO N/A YES NO

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

6

PEDESTRIAN COMPONENT (continued) DEPARTMENTAL

APPROVAL

15. When considering the overall design, does it create or enhance a pedestrian environment that provides safe and comfortable access for all pedestrians at all times of the day?

YES NO YES NO

APPLICANT: Pedestrian Component Additional Explanation / Comments: New curb and sidewalk will be installed along portions of St. James Street, South 12th Street, Chancellor Street, and South Camac Street. The existing sidewalk widths will all be maintained. A new entrance only driveway will be provided on St. James Street and a new exit only driveway will be on Chancellor Street. A curb cut will be provided on 12th St. to access the loading area. Trucks will be fully located within the property line and the owner plans to utilize flaggers to direct vehicles and pedestrians during loading activities.

DEPARTMENTAL REVIEW: Pedestrian Component

complete streets handbook checklist

Page 26: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 25

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

8

BUILDING & FURNISHING COMPONENT (continued)

APPLICANT: Building & Furnishing Component Additional Explanation / Comments: New curb and sidewalk will be installed along portions of St. James Street, Chancellor Street, South Camac Street, and South 12th Street frontages. The existing sidewalk widths will all be maintained. Bike Racks are proposed within the furnishing zone along South 12th Street frontage in accordance with the zoning requirements. Streets trees can't be provided to meet the spacing requirements of the Streets Dept FZ0102 diagram based on the existing utility mains and light poles within the adjacent street sidewalk

DEPARTMENTAL REVIEW: Building & Furnishing Component Reviewer Comments:

21. Do street trees and/or plants comply with street installation requirements (see sections 4.4.7 & 4.4.8)

YES NO N/A YES NO

22. Does the design maintain adequate visibility for all roadway users at intersections?

YES NO N/A YES NO

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

9

BICYCLE COMPONENT (Handbook Section 4.5) 23. List elements of the project that incorporate recommendations of the Pedestrian and Bicycle Plan, located online at

http://phila2035.org/wp-content/uploads/2012/06/bikePedfinal2.pdf On-street bicycle parking is provided on 12th St.

24. List the existing and proposed number of bicycle parking spaces, on- and off-street. Bicycle parking requirements are provided in The Philadelphia Code, Section 14-804.

BUILDING / ADDRESS REQUIRED SPACES

ON-STREET Existing / Proposed

ON SIDEWALK Existing / Proposed

OFF-STREET Existing / Proposed

Mixed Use Building/204 South 12th Street

150 0 / 0 N/A / 6 0 / 223

/ / / / / / / / /

25. Identify proposed “high priority” bicycle design treatments (see Handbook Table 1) that are

incorporated into the design plan, where width permits. Are the following “High Priority” elements identified and dimensioned on the plan?

DEPARTMENTAL APPROVAL

▪ Conventional Bike Lane YES NO N/A YES NO ▪ Buffered Bike Lane YES NO N/A YES NO ▪ Bicycle-Friendly Street ▪ Indego Bicycle Share Station

YES NO N/A YES NO N/A

YES NO YES NO

26. Does the design provide bicycle connections to local bicycle, trail, and transit networks?

YES NO N/A YES NO

27. Does the design provide convenient bicycle connections to residences, work places, and other destinations?

YES NO N/A YES NO

APPLICANT: Bicycle Component Additional Explanation / Comments: 223 bicycle parking spaces are provided within the building and 6 bicycle parking spaces are provided on 12th St sidewalk..

DEPARTMENTAL REVIEW: Bicycle Component Reviewer Comments:

complete streets handbook checklist

Page 27: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 26

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

10

CURBSIDE MANAGEMENT COMPONENT (Handbook Section 4.6) DEPARTMENTAL

APPROVAL

28. Does the design limit conflict among transportation modes along the curb?

YES NO YES NO

29. Does the design connect transit stops to the surrounding pedestrian network and destinations?

YES NO N/A YES NO

30. Does the design provide a buffer between the roadway and pedestrian traffic?

YES NO N/A YES NO

31. How does the proposed plan affect the accessibility, visibility, connectivity, and/or attractiveness of public transit?

YES NO

APPLICANT: Curbside Management Component Additional Explanation / Comments:

DEPARTMENTAL REVIEW: Curbside Management Component Reviewer Comments:

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

11

VEHICLE / CARTWAY COMPONENT (Handbook Section 4.7) 32. If lane changes are proposed, identify existing and proposed lane widths and the design speed for each street frontage;

STREET FROM TO LANE WIDTHS

Existing / Proposed DESIGN SPEED

N/A / / / /

DEPARTMENTAL

APPROVAL

33. What is the maximum AASHTO design vehicle being accommodated by the design?

Box truck SU-30 YES NO

34. Will the project affect a historically certified street? An inventory of historic streets(1) is maintained by the Philadelphia Historical Commission.

YES NO YES NO

35. Will the public right-of-way be used for loading and unloading activities?

YES NO YES NO

36. Does the design maintain emergency vehicle access? YES NO YES NO

37. Where new streets are being developed, does the design connect and extend the street grid?

YES NO N/A YES NO

38. Does the design support multiple alternative routes to and from destinations as well as within the site?

YES NO N/A YES NO

39. Overall, does the design balance vehicle mobility with the mobility and access of all other roadway users?

YES NO YES NO

APPLICANT: Vehicle / Cartway Component Additional Explanation / Comments: There will be 2 off-street loading spaces within the site accessed from South 12th Street.

DEPARTMENTAL REVIEW: Vehicle / Cartway Component Reviewer Comments:

(1) http://www.philadelphiastreets.com/images/uploads/documents/Historical_Street_Paving.pdf

complete streets handbook checklist

Page 28: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 27

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

ADDITIONAL COMMENTS

APPLICANT Additional Explanation / Comments:

DEPARTMENTAL REVIEW Additional Reviewer Comments:

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

12

URBAN DESIGN COMPONENT (Handbook Section 4.8) DEPARTMENTAL

APPROVAL

40. Does the design incorporate windows, storefronts, and other active uses facing the street?

YES NO N/A YES NO

41. Does the design provide driveway access that safely manages pedestrian / bicycle conflicts with vehicles (see Section 4.8.1)?

YES NO N/A YES NO

42. Does the design provide direct, safe, and accessible connections between transit stops/stations and building access points and destinations within the site?

YES NO N/A YES NO

APPLICANT: Urban Design Component Additional Explanation / Comments:

DEPARTMENTAL REVIEW: Urban Design Component Reviewer Comments:

COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission

13

INTERSECTIONS & CROSSINGS COMPONENT (Handbook Section 4.9) 43. If signal cycle changes are proposed, please identify Existing and Proposed Signal Cycle lengths; if not, go to question

No. 48. SIGNAL LOCATION EXISTING

CYCLE LENGTH PROPOSED CYCLE LENGTH

DEPARTMENTAL

APPROVAL

44. Does the design minimize the signal cycle length to reduce pedestrian wait time?

YES NO N/A YES NO

45. Does the design provide adequate clearance time for pedestrians to cross streets?

YES NO N/A YES NO

46. Does the design minimize pedestrian crossing distances by narrowing streets or travel lanes, extending curbs, reducing curb radii, or using medians or refuge islands to break up long crossings? If yes, City Plan Action may be required.

YES NO N/A YES NO

47. Identify “High Priority” intersection and crossing design treatments (see Handbook Table 1) that will be incorporated into the design, where width permits. Are the following “High Priority” design treatments identified and dimensioned on the plan?

YES NO

▪ Marked Crosswalks YES NO N/A YES NO ▪ Pedestrian Refuge Islands YES NO N/A YES NO ▪ Signal Timing and Operation YES NO N/A YES NO ▪ Bike Boxes YES NO N/A YES NO

48. Does the design reduce vehicle speeds and increase visibility for all modes at intersections?

YES NO N/A YES NO

49. Overall, do intersection designs limit conflicts between all modes and promote pedestrian and bicycle safety?

YES NO N/A YES NO

APPLICANT: Intersections & Crossings Component Additional Explanation / Comments:

DEPARTMENTAL REVIEW: Intersections & Crossings Component Reviewer Comments:

complete streets handbook checklist

Page 29: 204 s 12th street CIVIC DESIGN REVIEW 07.21€¦ · 204 s 12th street CIVIC DESIGN REVIEW 07.21.2020 civic design review 01 cdr project application form 02 area map 03 site photos

Civic Sustainable Design Checklist – Updated September 3, 2019

1

Civic Design Review Sustainable Design Checklist Sustainable design represents important city-wide concerns about environmental conservation and energy use. Development teams should try to integrate elements that meet many goals, including:

· Reuse of existing building stock · Incorporation of existing on-site natural habitats and landscape elements · Inclusion of high-performing stormwater control · Site and building massing to maximize daylight and reduce shading on adjacent sites · Reduction of energy use and the production of greenhouse gases · Promotion of reasonable access to transportation alternatives

The Sustainable Design Checklist asks for responses to specific benchmarks. These metrics go above and beyond the minimum requirements in the Zoning and Building codes. All benchmarks are based on adaptions from Leadership in Energy and Environmental Design (LEED) v4 unless otherwise noted.

Categories

Benchmark

Does project meet benchmark? If yes, please explain how. If no, please explain why not.

Location and Transportation

(1) Access to Quality Transit

Locate a functional entry of the project within a ¼-mile (400-meter) walking distance of existing or planned bus, streetcar, or rideshare stops, bus rapid transit stops, light or heavy rail stations.

(2) Reduced Parking Footprint

All new parking areas will be in the rear yard of the property or under the building, and unenclosed or uncovered parking areas are 40% or less of the site area.

(3) Green Vehicles

Designate 5% of all parking spaces used by the project as preferred parking for green vehicles or car share vehicles. Clearly identify and enforce for sole use by car share or green vehicles, which include plug-in electric vehicles and alternative fuel vehicles.

(4) Railway Setbacks (Excluding frontages facing trolleys/light rail or enclosed subsurface rail lines or subways)

To foster safety and maintain a quality of life protected from excessive noise and vibration, residential development with railway frontages should be setback from rail lines and the building’s exterior envelope, including windows, should reduce exterior sound transmission to 60dBA. (If setback used, specify distance)i

(5) Bike Share Station Incorporate a bike share station in coordination with and conformance to the standards of Philadelphia Bike Share.

Septa Broad Street subway, Walnutstreet station, 0.2 mi.Septa Bus Stops @ 12th and Locust &12th and Walnut Street,Patco 10th and Locust, 0.2 mi.

Yes, all on site parking is under thebuilding in the garage.

Yes, more than 5% of the parkingspaces are designated as Auto-shareparking spaces

NA, this site is not built up against arailway.

Bike share is not currently planned,however, the building is providing 210bikes spaces on site.

Civic Sustainable Design Checklist – Updated September 3, 2019

2

Water Efficiency

(6) Outdoor Water Use

Maintain on-site vegetation without irrigation. OR, Reduce of watering requirements at least 50% from the calculated baseline for the site's peak watering month.

Sustainable Sites

(7) Pervious Site Surfaces

Provides vegetated and/or pervious open space that is 30% or greater of the site's Open Area, as defined by the zoning code. Vegetated and/or green roofs can be included in this calculation.

(8) Rainwater Management

Conform to the stormwater requirements of the Philadelphia Water Department(PWD) and either: A) Develop a green street and donate it to PWD, designed and constructed in accordance with the PWD Green Streets Design Manual, OR B) Manage additional runoff from adjacent streets on the development site, designed and constructed in accordance with specifications of the PWD Stormwater Management Regulations

(9) Heat Island Reduction (excluding roofs)

Reduce the heat island effect through either of the following strategies for 50% or more of all on-site hardscapes: A) Hardscapes that have a high reflectance, an SRI>29. B) Shading by trees, structures, or solar panels.

Energy and Atmosphere

(10) Energy Commissioning and Energy Performance - Adherence to the New Building Code

PCPC notes that as of April 1, 2019 new energy conservation standards are required in the Philadelphia Building Code, based on recent updates of the International Energy Conservation Code (IECC) and the option to use ASHRAE 90.01-2016. PCPC staff asks the applicant to state which path they are taking for compliance, including their choice of code and any options being pursued under the 2018 IECC.ii

(11) Energy Commissioning and Energy Performance - Going beyond the code

Will the project pursue energy performance measures beyond what is required in the Philadelphia code by meeting any of these benchmarks? iii •Reduce energy consumption by achieving 10% energy savings or more from an established baseline using

Through the use of energy efficientbuilding systems, such as sustainableprinciples, such as a high efficiencyfacade, efficient lighting, low flowplumbing fixtures, condensing domesticwater boilers and a very high efficiencywater-cooled VRF system are beingapplied to the design for climate control,a goal of the project is to achieve a 10%energy savings.

Yes, plant selection made to minimizeirrigation requirements.

No, the amount of vegetation/previoussurface is less than 30% of the site’sopen area

Yes, The project will confirm to therequirements of the Philadelphia PWD,for management of the storm waterrunoff within the property boundary.

A) Yes, Hardscapes (roofing, somepaving) to have a SRI>29.

ASHRAE 90.1-2016 ComplianceModel

While the energy modeling has not yetbeen completed, the goal of this project isto achieve a 10% energy savings abovethe baseline standards by implementingsustainable design principals and usingefficient building systems such as highefficiency facade, energy efficient lighting,low flow plumbing fixtures, condensingdomestic water boilers, and a highefficiency water-cooled VFG system.

Civic Sustainable Design Checklist – Updated September 3, 2019

3

ASHRAE standard 90.1-2016 (LEED v4.1 metric). •Achieve certification in Energy Star for Multifamily New Construction (MFNC). •Achieve Passive House Certification

(12) Indoor Air Quality and Transportation

Any sites within 1000 feet of an interstate highway, state highway, or freeway will provide air filters for all regularly occupied spaces that have a Minimum Efficiency Reporting Value (MERV) of 13. Filters shall be installed prior to occupancy.iv

(13) On-Site Renewable Energy Produce renewable energy on-site that will provide at least 3% of the project's anticipated energy usage.

Innovation

(14) Innovation Any other sustainable measures that could positively impact the public realm.

i Railway Association of Canada (RAC)'s “Guidelines for New Development in Proximity to Railway Operations. Exterior Sound transmission standard from LEED v4, BD+C, Acoustic Performance Credit. ii Title 4 The Philadelphia Building Construction and Occupancy Code See also, “The Commercial Energy Code Compliance” information sheet: https://www.phila.gov/li/Documents/Commercial%20Energy%20Code%20Compliance%20Fact%20Sheet--Final.pdf and the “What Code Do I Use” information sheet: https://www.phila.gov/li/Documents/What%20Code%20Do%20I%20Use.pdf iii LEED 4.1, Optimize Energy Performance in LEED v4.1 For Energy Star: www.Energystar.gov For Passive House, see www.phius.org iv Section 99.04.504.6 "Filters" of the City of Los Angeles Municipal Code, from a 2016 Los Angeles Ordinance requiring enhanced air filters in homes near freeways

N/A - Site is not within 1000 feet of aninterstate highway.

No Currently no on-site renewableenergy is to be provided at this time.

No additional sustainability measuresare planned at this time.

21 july 2020204 s 12th street | civic design review |

© blt architects 2019

| 28sustainable design checklist