· 2020. 8. 9. · Tentec Bolt Load Software has been designed with the philosophy of minimal...
Transcript of · 2020. 8. 9. · Tentec Bolt Load Software has been designed with the philosophy of minimal...
Tentecwww.tentec.net
®
BTS - Bolt Tightening SoftwareBolt Tightening Solutions
www.tentec.net
Custom Tensioners
Available on Request.
Bolt Tightening Software Takes the Complexity out of Bolt Tensioning Calculation.
Tentec, a major UK manufacturer and supplier of bolt tensioning equipment announces the launch of new software to allow users to manage and rapidly calcu-late bolt tensioner pressures. Tentec Bolt Load Software has been designed with the philosophy of minimal input, maximum output. Documentation for multiple bolted joint projects can be created very quickly with minimal opera-tor input. The software package contains data for the fol-lowing standard bolted flanges:-
ANSI B16.5ANSI B16.47 Series A MSS SP-44API 6AAPI 17SVVector SPO Compact FlangesNorsok L-005
Tentec supply standard topside and subsea ranges of bolt tensioning equipment as well as specially designed bolt tensioning tool solutions, the software contains data for all of Tentec standard tool ranges and also offers the ability to create a user definable special tools library. Another useful feature offered by the software is “Manual Mode”, here the user can define a special bolted joint that is not a standard flanged joint. The software can handle both special “Blind Threaded” bolted joints as well as the conventional “Through Bolt” type joints.
The software is ideal for use by bolt tensioning Service companies who have to submit bolted joint tensioner data sheets to their customers. The output documentation can be easily re-branded to display the service companies name and logo.
The documentation package that the software produces consists of a summary sheet which provides an overall list and core information of all applications covered in the project and an individual detailed application sheets for every single joint contained in the project.
The software creates the following documentation:-
Individual Flange Document gives the following information...
• Recommended Tentec tensioning tool to use
• Recommended residual bolt stressw
• Recommended pressures to achieve residual bolt stress.
• Recommended bolt lengths for use with Tentec Bolt Tensioning Tools
• Recommended torque values, with variable lubrication factors
• Gives a graphical representation of predicted bolt stress path over time.
• Tensioner sequence information
Main window showing bolt tightening sequence.
Visitwww.tentec.net/bolt-tightening-software.phpTo register for your free copy of Tentec BTS
100% Tensioning Pressures
50% Tensioning Pressures
16877 1164
20253 1396
Max Detensioning Pressures 16877 1164
- - 59.1
16877 1164 71.0
- - 59.1
ClientProjectProject ReferenceDate and Engineer
Flange
IdentJoint Information
Nom Thread SizeTPINum BoltsBolt to Tensioning Ratio
Clamp LengthLoad Transfer Factor LTF
Proposed Tensioning ToolTool Pressure Area
Bolt InformationBolt MaterialBolt Yield StrengthTensile Stress AreaBolt Length
7.1/16 x 5000 - Type 6B
NEW APPLICATION
1.3/8"-8UN8
12
50%
7.9511.1829
CTST-024.578 2953.68
ASTM A193 - B7105152 7251.242 801.55
316.312.45
- Bolt Stress Bolt Load % of Bolt Yieldlbs/in2 N/mm2 Tons kN %
74631 514.56 41.39 412.44 71.0
62192 428.80 34.49 343.70 59.152576 362.50 29.16 290.56 50.0
31/10/2011
Proposed Tensioning Tool
Torque InformationTorque 16111188Coefficient of Friction 0.12
62192 428.80 34.49 343.70 59.1
Tensioning Pressures 1st Pass 2nd Pass % of Bolt Yield psi Bar psi Bar %
Tensioning Tool Information201.95
Stress @ Detensioning
Based on Tensile Stress Area
T1 @ A Pressure
T1 @ B Pressure
T2 Residual
Bolt Tensioning Datasheet
Flange ConfigurationF1
Gap
F2WsIn
BL
WN
mm
100 10
91.95
RN
In2
lb/in2
In2
mm
mm2
N/mm2
mm2
In
ft.lb N.m
Pass 1 1 20253 1396
Pass 2 2 16877 1164Pass 3Pass 4
Pass 1 1 16877 1164
Pass 1 1 16877 1164
Pass psi bar
TensionerBolt #
Applied Pressure
Checking Pass
Specification API 6A & 17D
Application Comments
0
20000
40000
60000
80000
100000
120000
T0 T1 T2 T3
Time Stages
Predicted Bolt
Max Detensioning Pressure refers to the maximum capacity of the tensioning tool and should not be considered to be the safe max load capacity of the flange100% Tensioning is the recommended mode of bolt tensioning, wherever possible use 100% Bolt to tool ratioTentec Limited do not accept any liability for errors within or caused by the use of this software. © 2012 Tentec Limited - All Rights Reserved
Individual flange bolting document.
Project View, displays all of the flanges in the current project
Custom Tensioners
Available on Request.
Bolt Tightening Software Takes the Complexity out of Bolt Tensioning Calculation.
Bolt window displays bolt lengths, bolt material, bolt strengths and bolt areas.
Tentec LimitedPlymouth House. Guns Lane
West Bromwich. West MidlandsUnited Kingdom. B70 9HS
Internet: www.tentec.netemail:[email protected]
Telephone: +44(0)121 524 1990Telefax: +44(0)121 525 1999ISO 9001BS OHSAS 18001ISO 14001
© 2012 - Tentec Limited. Document No: TDR:103r1
Tentec products are subject to continual development and we reserve the right to make changes in the specification and design of products without prior notice.
Header Ribbon displays project details and the current flange
Project View, displays all of the flanges in the current projectJoint Inspector, gives bolt information as you enter data.
Main window, choose a flange or define a special joint/
Tensioning sequence information.
Load Graph window, displays bolt stress over a 3 stage time period
Torque window, displays torque and definesCoefficient of friction
Tensioner window, displays dimensional detail of the tensioning tool.
Bolt Stress window, displays bolt stress, bolt load and % of bolt yield.
Bolt Tightening Software Takes the Complexity out of Bolt Tensioning Calculation.