hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 1 E CATALOG 4th Generation Hybrid NEW Technology B SCIENCE HDROZONE THE MOST EFFECTIVE AND SAFE SOLUTION IN LUMEN MATERIAL STERILIZATION There is no "Diameter and Length" Limit at FULL LOAD for any type of "Lumen Material" sterilization. (Ø 0,1 mm. ... DIAMETER, Min. 15 m. Length) hdrOzone LONG LUMEN STERILIZATION DEVICE MANIFACTURER: TEKNOMAR MAKİNA İMALAT İTHALAT İHRACAT SANAYİ ve TİCARET LTD. ŞTİ. Notified Body No: CE-1984

Transcript of HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon,...

Page 1: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 1

E CATALOG

4th Generation Hybrid NEW Technology

B SCIENCE

HDROZONE

THE MOST EFFECTIVE AND SAFE SOLUTION IN LUMEN MATERIAL STERILIZATION

There is no "Diameter and Length" Limit at FULL LOAD for

any type of "Lumen Material" sterilization.

(Ø 0,1 mm. ... DIAMETER, Min. 15 m. Length)

hdrOzone

LONG LUMEN STERILIZATION DEVICE

MANIFACTURER: TEKNOMAR MAKİNA İMALAT İTHALAT İHRACAT SANAYİ ve TİCARET LTD. ŞTİ. Notified Body No: CE-1984

Page 2: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 2

The B SCIENCE hdrOzon, sterilization device

can be safely used to sterilize all types of heat and

moisture sensitive medical instruments, plastics, lumen

materials, long lumen materials, electromechanical

instruments and surgical instruments and single and

multichannel, flexible endoscopes.

It can be used safely for the sterilization of long and

complex endoscopes, as well as for the sterilization of

multi-channel flexible lumen endoscopes with 4 channels

and 4.5 meters length. Sterilization effect up to Ø2mm,

length 15 meters.

B SCIENCE hdrOzon sterilization device, the

world's first, low-temperature (37 C - 45 C range) double-

sterilized, [Hydrogen Peroxide (H2O2) and Ozone (O3)]

heavy molecule and hydronium using cold plasma

sterilization system developed by TEKNOMAR

B SCIENCE hdrOzon sterilization devise is

working under vacuum. This device has no lumen,

diameter, length disadvantage and limitations as in other

hydrogen peroxide sterilization devices. In the sterilization of complex lumens, hdrOzon is much

more effective than H2O2 plasma sterilization. In

addition to the chemical reaction sterilization in the

device, the formation of hydroxyl radicals and plasma

activity are very high. It does not cause corrosion and

residues in sterilized products.

hdrOzon Hydrogen Peroxide Ozone Plasma Sterilization Materials are ready to use with

technological design and applications without needing extra ventilation. There is no harmful

waste, the last chemicals formed are water vapor and oxygen. Therefore, it provides safe

sterilization as well as safe use for personnel and the environment.

The device uses 60% Hydrogen Peroxide (H2O2) solution and Medical Oxygen for safe and

unrestricted sterilization. In this way, with the intelligent program design, the ozone and

hydrogen peroxide effects are used low dose for effective sterilization.

Page 3: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 3

hdrOzon Working Technique: With the application of H2O2 and O3, (HO3, HO4, H2O3,

H2O4, HO5, OOH, H3O ... etc.) HYDRONIUM, heavy molecules, radicals, hydroxyls, ion and

plasma sterilization is the effect of sterilization.

B SCIENCE hdrOZONE sterilization device working principle;

(After the boiler temperature has reached the desired temperature)

1. Vacuum phase

2. Injection phase

3. Diffusion phase

4. Ozone phase

5. Hydronium phase

6. Hydronium an ADSORPTION of heavy molecules phase

7. Dilution phase

8. Plasma phase

9. Ventilation -Aeration phase

hdrOzon Sterilization Diagram

In sterilization safety, the B SCIENCE hdrOzon

sterilization device uses a fixed programmed sterilization cycle

that eliminates the possible user error predicted.

There is no need to classify the materials to be sterilized and

to select the appropriate cycle and program as in the case of

prior art devices. Mixed loading can be done.

The device's ability to operate mixed loads maximizes device

efficiency, safe sterilization cycles, and reduces labor cost by

minimizing the amount of material classification to be sterilized.

Pressure-mbar

Time

Preparation H O2 2+OInjection

2 Dilution H O2 2+O2

InjectionDilution Plasma Ventilation

1. Cycle 2. Cycle

HidronyumAdsorption

HidronyumAdsorption

Dilution Dilution

Page 4: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 4

It offers simple and fast operation with predetermined

program options for language selection and sterilization

on the large touch screen.

Complies with ISO 14937 Sterilization validation

standards.

B SCIENCE hdrOzon sterilization device can be

used as a stand-alone Hydrogen Peroxide Sterilization

Plasma device

There are 3 programs of H2O2 + 2 programs of hdrOzon. There are 5 programs in total.

PCD and Lumen Sterilization

Hydrogen Peroxide H2O2 + O3 hdrOzon Plasma

Sterilization Device performs the sterilization

process of medical products and other similar

materials as well as classical disposable materials.

Sterilization of complex lumen material does not

require any apparatus (such as booster).

ENDOSCOPES Mixed loading of any length and diameter

No need for product classification or sizing

Rigid Endoscopes / lumens Flexible Endoscopes / lumens

Laryngoscope Arthroscopy

Laparoscopes Trocar Cannula

Trocar Case Resectoscope

And such

Bronchoscopy Ureteroscopy Hysteroscopy

Cystoscopy Koledoskop

And such

Device / Tool

Implants Defibrillator Pedals

Electrocautery Products Esophageal Dilators

Kri-Probe Doppler

Head Pressure Transducer Cables Endoscopic Products and so on

Fiber Optic Cables Laser Hand Products

Fiber Accessories Ophthalmic Lenses

Radiation Therapy Equipment Surgical Power Equipment

Drilling Tools Ultrasound Probes

Video Camera and connection apparatus and so on

i

KISASHORT

H O2 2

KISALONG

H O2 2

KISALUMEN

H O2 2

KISALOAD KISALONG

LUMEN

+O

H O2 2+

O

H O 2 2

Page 5: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 5

ADVANTAGES AND DISADVANTAGES OF hdrOzon STERILIZATION TECHNIQUE

Packaging properties: non-cellulose, synthetic materials such as polypropylene or tyvec; fabric,

cellulose and liquid sterilization is not suitable for this sterilization method.

Advantages of hdrOzon Technique in Sterilization

In the new hdrOzon technique and technology, not only the use of hydroxyl but also the

use of heavy molecules.

Use of H2O2 + O3 and gas hydronium instead of condensing H2O2.

All kinds of sterilization safety available.

No ventilation time required.

Full load sterilization with all types of products.

There is no need to separate and sterilize one by one when the material is placed in the

sterilization vessel, such as long lumen, short lumen, load and other materials.

Reduces material selection error to zero. Reduces the need for qualified personnel.

Non-wet moist materials can be sterilized. As with other hydrogen peroxide devices, no

product drying operation is required.

Completes the sterilization process at low temperature and humidity.

Suitable for temperature and moisture sensitive materials.

Sterilization of long and thin (0.5 mm * 100 cm) lumen materials sterilizers up to 15 meters

(2 mm diameter) at full load without the need for manufacturer's declaration.

There is no harm to the environment due to being H2O and O2 as the final product. Safe

method for environment and human health.

It is suitable for sterilization of very long and thin lumen flexible surgical instruments at full

load.

It is a non-toxic sterilization method.

Easy, comfortable and safe to use.

No auxiliary devices like booster are needed.

Short sterilization cycle time,

Fast sterilization at full load,

The cost of sterilization per material and the low labor cost are the advantages of this

method. Normal H2O2 device cartridge is used. Sterilization FULL load is done as compared

to normal H2O2 devices cartridge consumption is 1/3.

Disadvantages of hdrOzone Technique in Sterilization

Materials that absorb hydrogen peroxide, cause catalytic degradation of hydrogen peroxide,

react with hydrogen peroxide materials such as organic sulfides, silver.

No suitable sterilization method for cellulose, fabrics and liquids,

Use of cellulose-free polypropylene, synthetic material such as tyvec for packaging,

Connection to hospital oxygen and exhaust connection.

Page 6: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 6

Specifications / short Datasheet

hdrOzon DOCUMENTS

CE Certificate- 93/42/EEC YES

EN ISO 13485 YES

EN ISO 9001 YES

TUR (Technological Product Experience

Certificate) YES

Domestic Goods Certificate YES

Free Sales Certificate YES

UTS Registered YES

TEYDEP Project Success Certificate YES

LVD / EMC Tests and Certificates YES / EN 60601-1-1:2009

EN ISO 14937 Certificates YES

Prion Tests YES

Lumen Material Sterilization Test YES

Residue Test YES

Corrosion Test YES

Device Type Test YES

MODEL 3S75 3S125

TYPE B SCIENCE hdrOzon

B SCIENCE hdrOzon

SCREEN Touch screen 7” Touch screen 7”

OUTER DIMENSIONS (W-D-H) (mm)

730x955x1980 730x870x1980

INNER DIMENSIONS (W-D-H) (mm)

440x370x700 440x500x700

CHAMBER VOLUME (lt) 113 154

EFECTIVE VOLUME OF CHAMBER (lt)

92 131

CARTRIDGE H2O2 SOLUTION QUANTITY

120 cc 120 cc

*POWER (WATT)(Max.) 3200W 3200W

WORKING VOLTAGE 230 VAC, 50/60 Hz 230 VAC, 50/60 Hz

EXTERNAL CHASSIS MATERIAL STAINLESS STEEL

304 STAINLESS STEEL 304

CHAMBER MATERIAL STAINLESS STEEL

316 STAINLESS STEEL 316

Page 7: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 7

Ethylene Oxide, Hydrogen Peroxide and Ozone & Hydrogen Peroxide hdrOzone Sterilization Comparison Table

Sterilization Method Ethylene Oxide Hydrogen peroxide Hydrogen Peroxide & Ozone hdrozon

Teknomar EO - C2H4O H2O2 H2O2 & O3

Efficiency Effective Limited Effective High Efficiency on Lumens Products

Lumen Sterilization Time ~ 4-12 Hours ~ 70 Minutes ~ 95 Minutes (Load)

Sterilization Cost ~ 12,00* € ~9,00* € ~ 10,00

* €

Cartridge Storage Condition Compelling Appropriate Appropriate

Danger Level High Ecofriendly Ecological

Level of Preparation for Sterilization

Medium Long Short

Capacity High Capacity Limited Capacity High Capacity

Material Compatibility Mixed Material Different Programs for Different Products

Mixed Material

Air and Environment Pollution

Risky Ecological Ecological

External Connection Necessary Unnecessary Necessary

Operating temperature 37-55 ℃ 37-55 ℃ 37-45 ℃

Sterility Assurance (SAL) 10-6 10-6 10-6

Maintenance Reasonable Expensive Reasonable

Installation Hard Easy Easy

Working Principle Only EO H2O2 Gas Vapor or Plasma Only

1- H2O2

2- H2O2 & O3

3-Hydronium

Diameter and Length Unlimited 1 mm Ø - 400 mm /

Ø 2 mm- 1200 mm

Ø 0,1- 50cm Ø 2 mm Inner Diameter Min. 4,5 -15 Meter Length

Residue on Product Risky No residue on product / partial lumen

No residue on equipment and multi-channel long lumen materials

Approximate Cost of Device ~ 20.000,00 €* ~ 40.000,00 €* ~ 80.000,00 €*

Total Score 7/18 8/18 16/18

The table shows the comparison of sterilizers in terms of different parameters and properties.Although sterilization is precise in each of the methods, there are variables that must be considered from the end-user point of view.

The ranking shows that the most suitable sterilizer is the 16/18 rated Low Heat Ozone (O3) & Hydrogen Peroxide

hdrOzone (H2O2) Gas Plasma Sterilization Device. The Second Lumen is a Hydrogen Peroxide Gas

Plasma Sterilizer with 8/18 in terms of Cost and Capacity. Third, Ethylene Oxide Gas Sterilizer with limited advantages and high risks 7/18.

Page 8: HDROZONE · 2019-07-31 · hdrOzone B SCIENCE hdrOzone E CATALOG 8/ 2 The B SCIENCE hdrOzon, sterilization device can be safely used to sterilize all types of heat and moisture sensitive

hdrOzone

B SCIENCE hdrOzone E CATALOG 8/ 8

4th Generation Hybrid NEW Technology

B SCIENCE

HDROZONE

TEKNOMAR MAKİNA İMALAT İTH. İHR. SAN. VE TİC. LTD.ŞTİ. Ostim OSB Mahallesi 1269. Cadde No: 29 Yenimahalle ANKARA / TURKİYE 06370 Tel: +90 312 385 00 40 Fax: +90 312 385 67 84

www.teknomar.com.tr [email protected]

B SCIENCE

hdrOzone

LONG LUMEN STERILIZATION

DEVICE

MANIFACTURER: TEKNOMAR MAKİNA İMALAT İTHALAT İHRACAT SANAYİ ve TİCARET LTD. ŞTİ. Notified Body No: CE-1984