2017-05-04 S26 staff slides - San Clemente High...
Transcript of 2017-05-04 S26 staff slides - San Clemente High...
DRAWING TITLE REV
SCALE @ A1
PROJECT DWG NUMBER
#
REV. DESC. DATEAustin McFarland.ArchitectsSurry Hills+Wingham NSWPO BOX 395NEWTOWN NSW 2042 p. 02 65535580 m. 0400 802284architects@austinmcfarland .com.au abn 58 087 414 864
AMENDMENT NOTES
all dimensions are to be verified on site. all door and window dimensions are clear opening dimensions. steelwork, windows and joinery are to be check measured on site prior to manufacture . window schedules are drawn from the external view. Development Application 5/9/16A
New School Hall and Classrooms, San Clemente High School
S26
DA031:100
ALower Ground Floor Plan - Proposed
north
15000
15000
11m .
12m .
13m .
14m .
15m .
16m .
15m .
14m .
11m . 12m .
16m .
17m .
18m .
34450 6153 2825
1150 4500 4500 4500 4500 4500 4500 4500 1800
5000
2451
519
8585
6530
80
4314
5
1215
2000
033
00
12
34
56
78
91 0
1 11 2
1 31 4
1 51 6
RL 12.750
gas
met
erair
cond
itionin
g pl
ant
RL 13.700
RL 12.750
RL 13.080
RL 13.050
RL 13.050
RL 13.050
RL 12.400
ram
p
appr
ox 1
:23
ram
p
appr
ox 1
:8.7
ram
p
app
rox
1:9.
5
RL 13.080
RL 13.080
line of low wall to terrace edge below
RL18.35
New Hall
existing 3 storey building over
NewFoyer
NewHoldingKitchen
NewStoreroom
Corridor
high lever roof over shown dotted
low lever roof overshown dotted
12
34
56
78
910
111 2
1314
1 516
1718
1920
2122
12
34
56
78
12
34
56
78
12
34
56
78
910
1112
131 4
roof over shown dotted
FFL 13.100
FFL 13.100
FFL 13.100
FFL 13.100
NewAccessible
WC +shower
NewWomens
WC +Changeroom
change
change
shower
change
change
shower
open changearea
FFL 13.100ambamb
open changearea
NewMensWC +
ChangeroomFFL 13.100
NewLift
New Terrace
BOUNDARY
wate
r tan
kwa
ter t
ank
1DA21
2DA21
3DA22
4DA22
ADA23
20253
3353 43429
5500
CDA24
DDA24
BDA23
7365
2725
1442
5
Existing Administration Building
outline of proposed tree panting-refer to Landscape drawing for detail
Potential Stage Location
8.4m x 4.8
Pote
ntial
Sta
ge L
ocat
ion
8.4m
x 4
.8 Potential Stage Location
8.4m x 4.8
0 5 10 M
34450 6153 2825
1150 4500 4500 4500 4500 4500 4500 4500 1800
5000
2451
519
8585
6530
80
4314
5
1215
2000
033
00
12
34
56
78
91 0
1 11 2
1 31 4
1 51 6
RL 13.700
RL 16.580
line of low wall to terrace edge below
12
34
56
78
910
RL18.35
NewLift
Void toFoyer Below
Void toHall Below
NewClassroom
NewGallery
New Corridor
Existing Classroom
NewClassroom
New External Accessway
roof over shown dotted
low lever roof below
12
34
56
78
910
111 2
1314
1 516
1718
1920
2122
12
34
56
78
910
1112
131 4
12
34
56
78
12
34
56
78
12
34
56
7 89 10 11
high lever roof over shown dotted1
23
45
67
89
1011
1213
1415
1617
FFL 16.600FFL 16.600
FFL 16.600
FFL 16.580
gutter
line of low wall to terrace edge below
BOUNDARY
20253
1DA21
2DA21
3DA22
4DA22
ADA23
3353 4342955
00
CDA24
DDA24
BDA23
Existing Administration Building
5500
3200
outline of proposed tree panting-refer to Landscape drawing for detail
Potential Stage Location
8.4m x 4.8
Pote
ntial
Sta
ge L
ocat
ion
8.4m
x 4
.8
Potential Stage Locationbelow
8.4m x 4.8
0 5 10 M
DRAWING TITLE REV
SCALE @ A1
PROJECT DWG NUMBER
#
REV. DESC. DATEAustin McFarland.ArchitectsSurry Hills+Wingham NSWPO BOX 395NEWTOWN NSW 2042 p. 02 65535580 m. 0400 802284architects@austinmcfarland .com.au abn 58 087 414 864
AMENDMENT NOTES
all dimensions are to be verified on site. all door and window dimensions are clear opening dimensions. steelwork, windows and joinery are to be check measured on site prior to manufacture . window schedules are drawn from the external view. Development Application 5/9/16A
New School Hall and Classrooms, San Clemente High School
S26
DA041:100
AGround Floor Plan - Proposed
north
0 5 10 M