2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network...

46
2016/2017 Air conditioning

Transcript of 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network...

Page 1: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

2016/2017Air conditioning

Page 2: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

2

Contact Us

An international sales network

[ HEADQUARTERS ]3, avenue du Centre - Les Quadrants - Bâtiment A78280 Guyancourt - FRANCE

[ DOCUMENT LIBRARY ]http://lh.airwell-res.com

[ COMMERCIAL ]E-mail: [email protected]: +33 (0)1 76 21 82 00

[ AFTERSALES ]SPARE PARTS ORDERS E-mail: [email protected] SUPPORT E-mail: [email protected]: +33 (0)1 76 21 82 95Monday to Friday: from 9:00 am to 1:00 pm

and from 2:00 to 5:00 pm

www.electra-res.com

Contact details

Page 3: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

3

Table of contents

PAGE

OUR UNIQUE SOLUTIONS 4

ICONS GUIDE 8

HIGH WALL RANGE 10

JKD UPGRADE Inverter high wall mono & multisplit FLEXYMATCH

12

JMF UPGRADE On/Off high wall monosplit 14

DUCTED RANGE 16

OCD Inverter ducted medium static pressure mono & multisplit FLEXYMATCH

18

OBF On/off ducted medium static pressure 22

CASSETTE RANGE 24

KBD Inverter cassette mono & multisplit FLEXYMATCH

26

KBF On/off cassette 900x900 30

FLOOR CEILING RANGE 32

TBD Inverter floor ceiling monosplit 34

MULTISPLIT RANGE 36

VCZ Residential line FLEXYMATCH

38

TWIN Twin system 42

Version: March 2016

Page 4: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

4

Our unique solutions

Discover our 3 unique technologies

n WiFi solution

n New outdoor unit concept

n Automatic refrigerant leakage detection

INTERCLIMA+ELEC 2015

Page 5: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

Uni

que

tec

hno

log

ies

5

q Easy installation.q Control your A/C by mobile phone/tablet locally or from distance.q Can control: on-off, operation mode, fan speed, temperature set-up and timer.q Aesthetic hidden display.q Android and IOS compatibility.q JKD line: optional.

Control your A/C from anywhere at any timeAir conditioners controlled by mobile phone, tablet or computer with wireless router and internet.

CONTROL ALL HOME’S AIR CONDITIONNERS AIRWELL

Router

CONTROL YOUR A/C FROM ANYWHERE

&

Page 6: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

Unique technologies

6

New outdoor unit concept

REFRIGERANT LEAKAGE DETECTION

DISPLAY

New electronic card concept: n Upside-down designn 70% dust reduction n Higher reliability

New designed mounting: n Rigit design n Easy installation and maintenance n Time saving

New performances: n Heating capacity

until -15°Cn Lower noise level

q The electronic controller checks continuously the system parameters and identifies the presence of a refrigerant leakage. In a case of leakage, the system stops, protects the compressor from damage and avoids major service costs.

Automatic refrigerant leakage detection

Page 7: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

Uni

que

tec

hno

log

ies

7

4D

12

1

34

3D

1

23

q System design based on DC motors.q DC motor contributes directly to the system efficiency.q 4D design based on DC indoor motor, DC outdoor fan motor, DC inverter

compressor and Electronic expansion valve. q In 4D the system can work with optimized parameters in order to achieve

maximum performance and comfort.

DC Inverter technology 3D-4D

21 dB(A)

q Special design for low noise level.q Optimized solution suitable for bedrooms.

Super quiet

Compatible model: JKD

Compatible models: KBD / TBD / OCD

Page 8: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

8

Icons Guide

STERIONIZER

Generates sterionizer ions producing electrochemical

reaction destroying bacteria, viruses and

allergenic particles. Creates and ensure provisioning of natural and high quality air

in living environment.

NANO PHOTOCATALYTIC

FILTER

Oxidizes and degrades organic contaminants. It can eliminate up to

99.9% of bacteria and can efficiently block dusts.

ANTIBACTERIA FILTER

Eliminates fine particles and purifies the air from

bacteria.

AUTO CLEAN/DRY

Prevents development of bacteria and moistures

keeping the heat exchanger dry after a

cooling operation.

FRESH AIR

Cools the room bringing fresh air from outside.

FILTER CLEAN INDICATION

Control led asking for verification and

cleaning of the air filter.

FLEXY MATCH

Indoor units are compatible with split or multisplit

installation.

DC INVERTER

Compressor with high efficiency DC engine.

1 W STANDBY POWER

Maximum reduction of energy waste once the unit is in standby mode.

LOW VOLTAGE STARTUP

Designed to start the unit even if power is not stable.

LOW TEMPERATURE STARTUP

Unit powered on even when external temperature

goes down to -15°C.

R410A FLUID

Refrigerant fluid R410A.

R32 FLUID

Refrigerant fluid R32.

VAV COMPATIBILITY

Automatic air volumeAutomatic control of air

volume and system based on difference between real ambient temperature and

temperature setting.

ELECTRONIC EXPANSION VALVE

Precise control of coolant flow, optimization

of performance and compressor protection.

REFRIGERANT LEAKAGE DETECT

Indicates a refrigerant leakage on indoor unit

and stops the system for compressor protection.

I FEEL

Precise control of temperature all around the chosen zone via a remote

temperature sensor.

MOTORIZED 4D AIRFLOW

Heating and cooling operations are optimized

with an automatic horizontal and vertical

oscillation.

MULTIFLOW 360°

Air distribution system with great comfort

on 360° and 4 directions with motorized

opening control.

SLEEP MODE

Temperature in the room adjustment based on

sleeping habits.

SUPER QUIET

Top design for the lowest sound level.

AIR QUALITY/CLEAN

COMFORT FUNCTIONS

STANDARD OPTION

TECHNOLOGY

1WLow Low

FLEXYMATCH

AUTO

Page 9: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

9

TWIN APPLICATION

An outdoor unit is connected to two similar indoor units.

OUTDOOR BASE HEATER

Prevents ice production.

CRANKCASE HEATER

Protects compressor oil from freezing.

ALARM OUTPUT

Remote transmission of dysfunction errors.

UNIT ON INPUT

Displays on the remote the power on or power off

status of the unit.

DRY CONTACT ON/OFF

Connection to an external presence detection with

adjusted control of the unit and power saving when

the room is empty.

BMS COMPATIBLE

Connection to the BMS system via PCB adapter.

SERVICE MONITOR TOOL

PC interface for monitoring and adjusting the settings

of the unit.

WIFI

Air conditioner controlled via mobile phone, tablet

or computer through a wireless router and

internet.

POWER CONSUMPTION CONTROL

Energy consumption control reducing

the maximum power on the unit.

WIRED REMOTE CONTROL DIAGNOSTIC

Diagnostic mode through the remote of the indoor

unit.

OUTDOOR UNIT DIGITAL DIAGNOSTIC

Displays a digital error code for an easier

maintenance.

OUTDOOR UNIT NIGHT MODE DRY CONTACT

Engine speed limitation and noise level reduction

of the outdoor unit.

OUTDOOR UNIT STAND-BY

Power on or power off of the outdoor unit from

the remote.

OUTDOOR UNIT ALARM OUTPUT

Transmission of an air output default alarm to a remote system.

FULL LENGTH REFRIGERANT PRECHARGE

No additional fee, easy and affordable installation.

TECHNICIAN TEST MODE

Special mode optimizing the duration of intervention

of the technician.

LOW AMBIENT COOLING

Operating on cooling mode even with low external

temperature with advanced control system.

LOW AMBIENT HEATING

Specific conception of the unit allows operating on heating mode even with

low external temperature.

DIGITAL DISPLAY

Digital display of error codes or temperature

settings on the indoor unit.

TURBO MODE

Improved net power and fast reaction while reaching the temperature setting for

the room.

PROGRAMMABLE TIMER

Adjustable timer for power on and power off.

SELF DIAGNOSTIC

Unit failure indication through a blinking led

on the unit display.

LOW BATTERY INDICATION

Indicates a need for battery replacement

on the remote.

AUTO RESTART (MEMORY)

Restarts automatically the unit in the last used mode

when power is back.

REMOTE CONTROL LOCK

Locks the remote functions to avoid

unexpected actions.

ADVANCED DEFROST

Reduces the operation to a minimum, without supplying power during defrost in heating mode.

AUXILIARY HEATER

Relaunches the heating capacity when the systems runs at a very low ambient

temperature.

INTEGRATED WATER PUMP

Eliminates condensate for a simple and

smooth use.

LEFT/RIGHT DRAIN CONNEXION

Easy installation connecting condensate

tubing either on left or right side.

FREQUENCY CONTROL INCLUDING AIRFLOW

Adjusts the engine speed depending on the flow rate to optimize the air volume.

FUNCTION

CONTROL OPTION CONNECTIVITY

OUTDOOR UNIT OPTION

ODU ODU ODUSTBY

ODU

TESTMODE - °C

TURBO 24 H RESTART

BMSUNITON

Page 10: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

10

[ MODEL NAME ] Page7

2 kW9

2.5 kW12

3.5 kW18

5 kW24

7 kW

INVERTER HIGH WALL MONO & MULTISPLIT UPGRADE FLEXY

MATCHJKD 12

ON/OFF HIGH WALL UPGRADE JMF 14

Hig

h w

all R

ang

e

Page 11: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

11

[ MODEL NAME ] Page7

2 kW9

2.5 kW12

3.5 kW18

5 kW24

7 kW

INVERTER HIGH WALL MONO & MULTISPLIT UPGRADE FLEXY

MATCHJKD 12

ON/OFF HIGH WALL UPGRADE JMF 14

Page 12: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

12

JKDHIGH WALL MONO & MULTISPLIT

[ PRODUCT ADVANTAGES ]

WiFi option. Same indoor unit for multi and single applications. Left/right drain connexion. Multifan speed in indoor unit. Self clean/dry.

q High wall line available in capacities 2.65 up to 6.8 kW.q Operating down to -15°C in cooling and heating mode.q A++/A+++ class efficiency in cooling – minimum energy consumption.q “I Feel” function with precise room temperature control.

RC08B

RCW8(optional)

FEATURES

OPTIONSAccessory Reference Photo Function

Wired single control RCW8

7ACEL1706 Mode, fan speed, timer ON/OFF, temperature, swing and “I Feel”.

Test tool for high wall

7ACEL1710 Easy viewing of system parameters, history, failure records and parameter adjustments.

ON-OFF dry contact adaptor

7ACEL1190 Remote control based on last memorized operation.

Wifi module 7ACEL1719Control air conditioners with your mobile phone, tablet or computer with wireless router and internet.

REFRIGERANT LEAKAGE DETECTION ALARM SYSTEMWIFI OPTION

REFRIGERANT LEAKAGE DETECTION

DISPLAY

UPGRADE

FLEXY MATCH

FLEXYMATCH

DC INVERTER

1W

1 W STANDBY POWER R410A FLUID REFRIGERANT LEAKAGE DETECT

NANO PHOTOCATALYTIC

FILTER

ANTIBACTERIA FILTER

AUTO CLEAN/DRY

AUTO

I FEEL SLEEP MODE DIGITAL DISPLAY

TURBO MODE

TURBO

PROGRAMMABLE TIMER

24 H

SELF DIAGNOSTIC LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

LEFT/RIGHT DRAIN CONNEXION

LOW AMBIENT COOLING

- °C

LOW AMBIENT HEATING

°C-SERVICE MONITOR

TOOLWIFI

Monosplit DCI

A++++

Page 13: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

13

ELECTRA SOLUTIONS

JKD TECHNICAL DATAIndoor units ELSI-JKD009-N11 ELSI-JKD012-N11 ELSI-JKD018-N11 ELSI-JKD024-N11

Outdoor units ELAU-VKD009-H11 ELAU-VKD012-H11 ELAU-VKD018-H11 ELAU-VKD024-H11

COOLING

Rated capacity kW 2.65 (1.2-3.3) 3.54 (1.3-4.4) 5.0 (1.8-6.1) 6.8 (2.7-7.8)

Pdesignc kW 2.65 3.54 5.0 6.8

Rated power input kW 0.775 1.096 1.55 2.41

SEER/Energy label 6.9/A++ 6.8/A++ 6.5/A++ 6.3/A++

Operating limits °C -15°/50° Dry bulb

HEATING

Rated capacity kW 2.8 (0.85-3.7) 3.5 (1.2-4.8) 5.0 (1.4-6.7) 7.5 (1.6-8.7)

Pdesignh (average climate) kW 2.4 2.6 4.2 5.5

Pdesignh (warmer climate) kW 2.8 3.2 4.6 6.7

Pdesignh (colder climate) kW 3 3.2 5 7

Rated power input kW 0.72 0.94 1.35 2.34

SCOP/Energy label (average climate) 4/A+ 4.4/A+ 4.2/A+ 4/A+

SCOP/Energy label (warmer climate) 5.1/A+++ 5.3/A+++ 5.1/A+++ 5.1/A+++

SCOP/Energy label (colder climate) 3.3/B 3.4/A 3.3/B 3.3/B

Operating limits °C -15°/30° Dry bulb

Capacity @ -10°C kW 2.70 3.00 4.10 6.20

Capacity @ -15°C kW 2.40 2.50 3.60 5.50

INDOOR UNIT

Sound pressure level to 1 m (VL/LS/MS/HS) dB(A) 22/31/35/38 23/29/32/36 23/29/33/36 31/37/40/43

Sound power level dB(A) 54 53 57 63

Airflow (VL/LS/MS/HS) m³/h 230/320/380/430 310/390/430/480 360/460/540/610 650/820/890/960

Dehumidification l/h 1.0 1.2 1.7 2.4

Outline dimensions (WxHxD) mm 715x250x188 800x275x188 940x275 x205 1045x315x235

Package dimensions (WxHxD) mm 775x324x260 865x350x265 1015x350x265 1135x395x315

Net weight/Gross weight kg 6.5/8.2 7.4/9.5 9/12.2 12/15.2

Part number ESP022504 ESP022505 ESP022506 ESP022507

OUTDOOR UNIT

Sound pressure level to 1 m dB(A) 50 52 55 59

Sound power level dB(A) 60 62 65 68

Airflow m³/h 1900 2000 2100 2700

Compressor type Rotary DC Inverter Rotary DC Inverter Rotary DC Inverter Rotary DC Inverter

Outline dimensions (WxHxD) mm 770x300x555 800x333x554 800x333x554 845x363x702

Package dimensions (WxHxD) mm 900x345x585 920x390x615 920x390x615 965x395x755

Net weight/Gross weight kg 26.6/29 29.1/31.9 37.8/40.5 48.4/51.6

Part number ESP062766 ESP062767 ESP062768 ESP062769

POWER SUPPLY 1~230V - 50 HZ

Power supply side Outdoor Outdoor Outdoor Outdoor

Power cable section mm² 3x1.5 3x1.5 3x1.5 3x2.5

Fuse rating A 10 10 16 25

Electrical connections mm² 5x1.5 5x1.5 5x1.5 5x2.5

PIPE LINE

Suction pipe diameter inches 3/8” 3/8” 1/2” 5/8”

Liquid pipe diameter inches 1/4” 1/4” 1/4” 3/8”

Max length m 25 25 30 50

Max height m 10 10 20 25

IDU Compatible with ODU

High wall ODU single ODU multi

JKD 9 to 18VKD VCZ

JKD 24

VKD

Page 14: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

14

JMFHIGH WALL

[ PRODUCT ADVANTAGES ]

Refrigerant leakage alarm to protect the unit. Wider angle or air distribution. A/A class efficiency with minimum energy consumptions (sizes 7/9/12/18).

q High wall line available in capacities from 2.2 to 7 kW.q Digital display with room and set temperature.q Cooling and heating operation mode.q Photocatalytic and antibacterial filters.q ”I Feel” function with precise room temperature control.

RC08B

RCW8 (optional)

OPTIONSAccessory Part number Photo Function

Wired single control RCW8

7ACEL1706 Mode, fan speed, timer ON/OFF, temperature, swing and ”I Feel”.

ON-OFF dry contact adaptor

7ACEL1190 Remote control based on last memorized operation.

Fixed Speed

FEATURES

UPGRADE

REFRIGERANT LEAKAGE DETECTION ALARM SYSTEM

REFRIGERANT LEAKAGE DETECTION

DISPLAY

A/A CLASS EFFICIENCY

(JMF 7-9-12-18)

CLASS

R410A FLUID REFRIGERANT LEAKAGE DETECT

NANO PHOTOCATALYTIC

FILTER

AUTO CLEAN/DRY

AUTO

I FEEL SLEEP MODE DIGITAL DISPLAY TURBO MODE

TURBO

LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

8°C CONSTANT TEMPERATURE

HEATING

8°C

LEFT/RIGHT DRAIN CONNEXION

Page 15: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

15

Indoor units ELSI-JMF007-N11

ELSI-JMF009-N11

ELSI-JMF012-N11

ELSI-JMF018-N11

ELSI-JMF024-N11

Outdoor units ELAU-VMF007-H11

ELAU-VMF009-H11

ELAU-VMF012-H11

ELAU-VMF018-H11

ELAU-VMF024-H11

COOLING

Rated capacity kW 2.2 2.6 3.5 5.3 7.0

Input power kW 0.685 0.805 1.090 1.650 2.500

EER/Energy label 3.23/A 3.22/A 3.23/A 3.22/A 2.81/C

Operating limits °C 18°/43° Dry bulb

HEATING

Rated capacity kW 2.3 2.8 3.8 5.8 7.5

Input power kW 0.635 0.775 1.050 1.605 2.335

COP/Energy label 3.61/A 3.61/A 3.61/A 3.61/A 3.21/C

Operating limits °C -7°/24° Dry bulb

INDOOR UNIT

Sound pressure level to 1 m (LS/MS/HS) dB(A) 39/33/27 39/33/27 40/36/28 44/39/31 46/43/37

Sound power level dB(A) 49 49 50 54 56

Airflow (LS/MS/HS) m³/h 430/310/250 490/370/270 580/490/370 800/670/450 1100/1000/780

Dehumidification l/h 0.7 0.8 1.2 1.8 3

Outline dimensions (WxHxD) mm 715x250x188 715x250x188 800x275x188 940x275x205 1045x315x235

Package dimensions (WxHxD) mm 775x260x324 775x260x324 865x265x350 1015x265x350 1135x395x315

Net weight/Gross weight kg 6.9/8.7 6.9/8.7 8.0/10.0 10/12 12.7/16.1

Part number ESP022498 ESP022508 ESP022509 ESP022510 ESP022511

OUTDOOR UNIT

Sound pressure level to 1 m dB(A) 53 54 56 58 60

Sound power level dB(A) 63 64 66 68 70

Airflow m³/h 1700 1700 2000 2300 2800

Compressor type Rotary Rotary Rotary Rotary Rotary

Outline dimensions (WxHxD) mm 700x270x550 700x270x550 770x300x555 770x300x555 845x363x702

Package dimensions (WxHxD) mm 815x325x615 815x325x615 900x345x585 900x345x585 965x395x755

Net weight/Gross weight kg 23.7/25.9 24.5/26.5 30.2/32.4 36.5/38.5 49/52

Part number ESP062754 ESP062770 ESP062771 ESP062772 ESP062773

POWER SUPPLY 1~230V - 50 HZ

Power supply side Indoor Indoor Indoor Indoor Outdoor

Power cable section mm² 3x1.5 3x1.5 3x1.5 3x1.5 3x2.5

Fuse rating A 10 10 10 16 25

Electrical connections mm² 5x1.0 5x1.0 5x1.0 3x1.5 + 2x0.75 4x1.0

PIPE LINE

Suction pipe diameter inches 3/8” 3/8” 3/8” 1/2” 5/8”

Liquid pipe diameter inches 1/4” 1/4” 1/4” 1/4” 3/8”

Max length m 20 20 20 25 25

Max height m 8 8 8 10 10

ELECTRA SOLUTIONS

JMF TECHNICAL DATA

IDU Compatible with ODU

High wall ODU single

JMF 7 to 18 VMF

JMF 24VMF

Page 16: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

16

Duc

ted

Ran

ge

[ MODEL NAME ] Page12

3.5 kW18

5 kW24

7 kW30

8 kW36

10 kW45

12.5 kW60

16 kW

INVERTER DUCTED MEDIUM STATIC PRESSURE MONOSPLITMULTISPLIT Q ONLY SIZE 12

FLEXYMATCH

TWIN APPLICATION

OCD 18

ON/OFF DUCTED MEDIUM STATIC PRESSURE OBF 22

Page 17: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

17

[ MODEL NAME ] Page12

3.5 kW18

5 kW24

7 kW30

8 kW36

10 kW45

12.5 kW60

16 kW

INVERTER DUCTED MEDIUM STATIC PRESSURE MONOSPLITMULTISPLIT Q ONLY SIZE 12

FLEXYMATCH

TWIN APPLICATION

OCD 18

ON/OFF DUCTED MEDIUM STATIC PRESSURE OBF 22

Page 18: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

18

Unique solutions

OCD

Page 19: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

Uni

que

so

luti

ons

19

Capacity combinations Indoor units Outdoor units

Twin system

OCD018 + OCD018 VLD036

OCD024 + OCD024 VLD048

OCD030 + OCD030 VLD060

MANDATORY ACCESSORIESAccessory Reference Photo Description Function

Branch gas 7ACFH0476 Twin branch suction Tube branch to collect all suction lines.Mandatory for Twin application.

Branch liquid 7ACFH0477 Twin branch liquid Tube branch to collect all liquid lines.Mandatory for Twin application.

Tubing & charge instructions VLD036 VLD048 VLD060

Pipe diameter (liquid-gas) (inches) 3/8”-5/8”

Max length (m) 30 50 50

Max. difference in branch length (m) 10

Max. height drop between indoor units (m) 0.5

Max. height drop between indoor and outdoor units (m) 20

Max. branch length (m) 15

Twin application

Suction twin branch: 7ACFH0476

Liquid twin branch: 7ACFH0477

A

TWIN APPLICATION

The most cost saving solution for single-area spaces:

q Simple installation by having one refrigerant and control system.

q Space saving by using one outdoor unit instead of two.

q Low cost installation.

q Simple control, one control station for big space.

q Option to control by wireless or wired controller.

q Ducted or cassette application.

The twin application is used mainly in big open space where the total space area is controlled one controller only for 2 units. Airwell twin design allows to connect two similar indoor units to one common outdoor unit. The two indoor units are working in a same mode and set up only once, one indoor unit used as master.

Page 20: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

20

OCDDUCTED MEDIUM STATIC PRESSURE MONOSPLIT / MULTISPLIT Q Only size 12

[ PRODUCT ADVANTAGES ]

Full range of accessories and controls. Possibility to wire a water pump. Air return option from rear or bottom side. Option to connect to central controller or wireless remote control. Air filter is included. Twin application.

q Ducted line available in capacities from 3.5 up to 16 kW.q Cooling & heating operation mode.q DC Inverter and sine wave compressor drive technology.q “I Feel” function with precise room temperature control.q Available in 3PH from 10 kW.

RCW8 (STD)

RCW6(optional)

RC08B(optional)

OPTIONSAccessory Reference Photo Function

Air return grill OCD12 7ACVF0559

Air return grill OCD18/24 7ACVF0561

Air return grill OCD30 7ACVF0562

Air return grill OCD36/48 7ACVF0563

Air duct plenum OCD12 7ACEL1699

Air duct plenum OCD18/24 7ACEL1701

Air duct plenum OCD30/36/48 7ACEL1702

Wireless controller RC08B 7ACEL1712 Operating mode, temperature up and down, fan speed selection, “I Feel” function, horizontal and vertical flap swing, timer, silent mode.

Wired single control RCW6(except for OCD012) 7ACEL1704 Mode, fan speed, real time, timer, temperature, weekly timer, swing and “I Feel”.

Central controller(except for OCD012) 7ACEL1707 Controls up to 64 indoor units with indivitual setting failure codes indication, ON-OFF dry

contact, last operation memory, Modbus.

BMS gateway 7ACEL1708 Maximum 1024 units could be connected (16 gateways).

A++

TWIN APPLICATION

FEATURES

Monosplit DCI

FLEXY MATCH

FLEXYMATCH

DC INVERTER R410A FLUID ELECTRONIC EXPANSION VALVE

FRESH AIR I FEEL SLEEP MODE DIGITAL DISPLAY PROGRAMMABLE TIMER

24 H

SELF DIAGNOSTIC LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

INTEGRATED WATER PUMP

TWIN APPLICATION ALARM OUTPUT UNIT ON INPUT

UNITON

LOW AMBIENT COOLING

- °C

LOW AMBIENT HEATING

°C-BMS COMPATIBLE

BMS

Page 21: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

21

Indoor units ELSI-OCD012-N11

ELSI-OCD018-N11

ELSI-OCD024-N11

ELSI-OCD036-N11

ELSI-OID042-N11

ELSI-OID048-N11

ELSI-OID048-N11

ELSI-OCD060-N11

Outdoor units 1~230V - 50 Hz ELAU-VLD012-H11

ELAU-VLD018-H11

ELAU-VLD024-H11

ELAU-VLD036-H11

ELAU-VMD042-H11

ELAU-VMD048-H11 - -

Outdoor units 3~400V - 50 Hz - N - - - - - - ELAU-VLD048-H13

ELAU-VLD060-H13

COOLING

Rated capacity kW 3.5 (1.1~4.0) 5.3 (1.5~6.4) 7 (2.0~7.9) 10 (3.2~11.6) 12.1 (3.2~13.2) 14.0 (4.1~16.4) 14.0 (4.5~15.2) 16.0 (5.6~17.6)

Pdesignc kW 3.5 5.3 7 10 12.1 14 - -

Rated power input kW 1.09 1.65 2.18 3.32 4.09 4.96 4.36 4.97

SEER/Energy label 5.1/A 6.4/A++ 6.6/A++ 5.3/A 5.6/A+ 6.1/A++ 3.21/A 3.22/A

Operating limits °C -15°/50° Dry bulb

HEATING

Rated capacity kW 3.8 (1.1~4.5) 5.6 (1.5~6.8) 7.8 (2.0~8.8) 11.0 (3.2~12.5) 12.4 (2.9~14.6) 16.0 (4.3~18.0) 17 (5.2~18.2) 19.5 (6.0~21.2)

Pdesignh (average climate) kW 3.4 5.1 7.8 10.2 11 11.8 - -

Pdesignh (warmer climate) kW 3.5 5.1 7.8 10.5 11.6 11.8 - -

Rated power input kW 1.05 1.47 2.14 3.05 3.54 5.30 4.57 5.39

SCOP/Energy label (average climate) 3.8/A 3.8/A 3.8/A 3.8/A 4/A+ 4/A+ 3.72/A 3.62/A

SCOP/Energy Label (warmer climate) 4.8/A++ 4.8/A++ 4.6/A++ 4.4/A++ 5.1/A+++ 5.1/A+++ - -

Operating limits °C -15°/24° Dry bulb

Capacity @ -10°C kW 3 4.3 6.6 9 - 8.5 13.6 15.6

Capacity @ -15°C kW 2.7 3.6 5.8 7.9 - 7.8 11 12.6

INDOOR UNIT

Sound pressure level to 1 m (LS/MS/HS) dB(A) 36/39/41 39/43/45 39/43/46 36/39/42 44/47/50 45/48/51/48 36/39/42 51/54/57

Sound power level dB(A) 58 58 63 62 68 68 62 67

Airflow (LS/MS/HS) m³/h 410/440/560 800/950/1250 800/950/1250 1180/1560/1740 1600/1900/2200 1600/1900/2200 -/1640/2410 1940/2410/3010

External static pressure Range Pa 25 (0~40) 25 (0-60) 25 (0-80) 37 (0~80) 50 (0-100) 50 (0-100) 50 (0~100) 50 (0~200)

Dehumidification l/h 1.5 2.0 2.3 3.5 4.2 4.5 4.5 5.0

Outline dimensions (WxHxD) mm 700x210x635 920x270x635 920x270x635 1200x300x865 1200x300x865 1200x300x865 1200x300x865 1400x440x858

Package dimensions (WxHxD) mm 915x290x655 1135x350x655 1135x350x655 1385x373x920 1405x373x920 1405x373x920 1385x373x920 1590x470x895

Net weight/Gross weight kg 18/22.8 28/31.5 28/31.5 44/52.5 43.4/52 43.2/51.6 44/53 75/83

Part number ESP032030 ESP032031 ESP032032 ESP032034 ESP032038 ESP032039 ESP032039 ESP032037

OUTDOOR UNIT

Sound pressure level to 1 m dB(A) 52 55 57 60 - - 61 61

Sound power level dB(A) 62 65 69 70 71 72 70 70

Airflow m³/h 2200 2500 3500 5500 4300 6800 7200 7500

Compressor type Rotary DCI Rotary DCI Twin Rotary DCI Twin Rotary DCI Rotary DCI Rotary DCI Twin Rotary DCI Twin Rotary DCI

Outline dimensions (WxHxD) mm 760x590x285 845x700x320 900x860x315 990x965x345 946x810x410 952x1333x410 938x1369x392 938x1369x392

Package dimensions (WxHxD) mm 887x645x355 965x755x395 1043x915x395 1120x1100x435 1090x865x500 1095x1470x500 1095x1505x495 1095x1505x495

Net weight/Gross weight kg 35.4/37.9 46/50 59/63 73/83 70.5/76.1 95.1/108.4 102.5/116 102.5/116

Part number 1~230V - 50 Hz ESP062821 ESP062822 ESP062823 ESP062825 ESP062830 ESP062831 - -

Part number 3~400V - 50 Hz - N - - - - - - ESP062826 ESP062829

POWER SUPPLY 1~230V - 50 HZ

Power supply side Outdoor Ind. & Out. Ind. & Out. Ind. & Out. Ind. & Out. Ind. & Out. - -

Power cable section mm² 3x1.5 3x1.0+3x2.5 3x1.0+3x2.5 3x1.0+3x4.0 3x1.0 + 3x4.0 3x1.0 + 3x4.0 - -

Fuse rating am A 16 10+16 10+20 10+30 10 + 30 10 + 40 - -

Electrical connections mm² 4x1.0 3x0.5 3x0.5 3x0.5 2x0.5 2x0.5 - -

POWER SUPPLY 3~400V - 50 HZ - N

Power supply side - - - - - - Ind. & Out. Ind. & Out.

Power cable section mm² - - - - - - 3x1.0+5x2.5 3x1.0+5x2.5

Fuse rating am A - - - - - - 10+25 10+25

Electrical connections mm² - - - - - - 3x0.5 3x0.5

PIPE LINE

Suction pipe diameter inches 3/8” 1/2” 5/8” 5/8” 5/8” 5/8” 5/8” 3/4”

Liquid pipe diameter inches 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”

Max length m 20 30 50 65 65 65 65 65

Max height m 10 20 25 30 30 30 30 30

ELECTRA SOLUTIONS

OCD TECHNICAL DATA

IDU Compatible with ODU

Ducted ODU single ODU multi

OCD 12VLD VCZ

OCD 18 to 36 VLD

OCD 48 & 60VLD

Page 22: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

22

OBFON/OFF DUCTED MEDIUM STATIC PRESSURE

[ PRODUCT ADVANTAGES ]

Integrated water pump. Static pressure control. Optional parallel installation of similar indoor units. Option to connect air return plenum from rear or bottom side. External static pressure up to 100 Pa.

q Ducted line available in capacities from 7.2 up to 14 KW.q Cooling and heating operation mode.q Available in 3PH.q Wired control as a standard.

RCW8

RC08B (optional)

OPTIONSAccessory Reference Photo Function

Air return grill OBF42/60 7ACVF0563

Wireless controller RC08B 7ACEL1712Operating mode, temperature up and down, fan speed selection, “I Feel” function, horizontal and vertical flap swing, timer, silent mode.

Wired single control RCW6 7ACEL1704 Mode, fan speed, real time, timer, temperature, weekly timer, swing and “I Feel”.

Central controller 7ACEL1707Controls up to 64 indoor units with indivitual setting failure codes indication, ON-OFF dry contact, last operation memory, Modbus.

BMS gateway 7ACEL1708 Maximum 1024 units could be connected (16 gateways).

FEATURES

G

OOD QUALITY

PRICE RATIOFIXED SPEEDFIXED SPEED

R410A FLUID ELECTRONIC EXPANSION VALVE

ANTIBACTERIA FILTER

FRESH AIR I FEEL SLEEP MODE DIGITAL DISPLAY PROGRAMMABLE TIMER

24 H

SELF DIAGNOSTIC LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

INTEGRATED WATER PUMP

STATIC PRESSURE CONTROL

ALARM OUTPUT UNIT ON INPUT

UNITON

BMS COMPATIBLE

BMS

Fixed Speed

Page 23: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

23

ELECTRA SOLUTIONS

OBF TECHNICAL DATAIndoor units ELSI-OBF024-N11 ELSI-OBF030-N11 ELSI-OBF036-N11 ELSI-OBF048-N11

Outdoor units 1-230V - 50 Hz ELAU-VOF024-H11 ELAU-VOF030-H11 ELAU-VOF036-H11 -

Outdoor units 3-400V - 50 Hz - - - ELAU-VOF048-H13

COOLINGRated capacity kW 7.2 8.7 10.4 14

Input power kW 2.62 3.24 4.31 4.96

EER/Energy label 2.75/D 2.68/D 2.41/E 2.82/C

Operating limits °C 18°/43° Dry bulb

HEATINGRated capacity kW 7.4 9.1 11.6 15.6

Input power kW 2.52 2.79 3.60 4.31

COP/Energy label 2.93/D 3.26/C 3.22/C 3.62/A

Operating limits °C -7°/24° Dry bulb

INDOOR UNITSound pressure level to 1 m (LS/MS/HS) dB(A) 34/37/44 40/42/48 40/43/49 40/45/49

Sound power level dB(A) 54 58 59 59

Airflow (LS/MS/HS) m³/h 1000/1100/1400 1720/1940/2250 1650/1890/2270 1700/2100/2500

Dehumidification l/h 2.4 2.5 2.9 4.3

External static pressure range Pa 40 (0~70) 50 (0~80) 50 (0~80) 70 (0~100)

Outline dimensions (WxHxD) mm 920x270x635 1140x270x775 1140x270x775 1200x300x865

Package dimensions (WxHxD) mm 1135x350x655 1355x350x795 1355x350x795 1385x373x920

Net weight/Gross weight kg 26.5/32 37/43 36/43 45/53

Part number ESP032025 ESP032026 ESP032027 ESP032028

OUTDOOR UNITSound pressure level to 1 m dB(A) 59 61 61 62

Sound power level dB(A) 69 71 71 72

Airflow m³/h 2700 5200 5500 7200

Compressor type Rotary Rotary Scroll Scroll

Outline dimensions (WxHxD) mm 845x700x320 990x965x345 990x965x345 938x1369x392

Package dimensions (WxHxD) mm 965x755x395 1120x1100x435 1120x1100x435 1095x1505x495

Net weight/Gross weight kg 48/54.5 67.1/77.2 84.5/94.5 110/124

Part number 1~230V - 50 Hz ESP062759 ESP062760 ESP062761 -

Part number 3~400V - 50 Hz - - - ESP062763

POWER SUPPLY 1~230V - 50 HZ

Power supply side Indoor Indoor Indoor -

Power cable section mm² 3x2.5 3x4.0 3x4.0 -

Fuse rating am A 25 30 30 -

Electrical connections mm² 3x2.5 + 3x1.0 + 2x0.5

3x4.0 + 3x1.0 + 2x0.5

3x4.0 + 3x1.0 + 2x0.5 -

POWER SUPPLY 3~400V - 50 HZ

Power supply side - - - Indoor & Outdoor

Power cable section mm² - - - 3x1.0 + 5x2.5

Fuse rating am A - - - 16 + 20

Electrical connections mm² - - - 3x0.5

PIPE LINESuction pipe diameter inches 5/8” 3/4” 3/4” 3/4”

Liquid pipe diameter inches 3/8” 3/8” 3/8” 3/8”

Max length m 25 25 30 50

Max height m 15 15 20 25

IDU Compatible with ODU

High wall ODU single

OBF 24 to 36VOF

OBF 48

VOF

Page 24: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

24

[ MODEL NAME ] Page12

3.5 kW18

5 kW24

7 kW36

10 kW48

12.5 kW

INVERTER CASSETTE MONOSPLIT MULTISPLIT Q ONLY SIZES 12 & 18

FLEXYMATCH

TWIN APPLICATION

KBD 26

ON/OFF CASSETTE KBF 30

Cas

sett

e R

ang

e

Page 25: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

25

[ MODEL NAME ] Page12

3.5 kW18

5 kW24

7 kW36

10 kW48

12.5 kW

INVERTER CASSETTE MONOSPLIT MULTISPLIT Q ONLY SIZES 12 & 18

FLEXYMATCH

TWIN APPLICATION

KBD 26

ON/OFF CASSETTE KBF 30

Page 26: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

26

Unique solutions

KBD

Page 27: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

Uni

que

so

luti

ons

27

MANDATORY ACCESSORIESAccessory Reference Photo Description Function

Branch gas 7ACFH0476 Twin branch suction Tube branch to collect all suction lines.Mandatory for Twin application.

Branch liquid 7ACFH0477 Twin branch liquid Tube branch to collect all liquid lines.Mandatory for Twin application.

Suction twin branch: 7ACFH0476

Liquid twin branch: 7ACFH0477

A

The most cost saving solution for single-area spaces:

q Simple installation by having one refrigerant and control system.

q Space saving by using one outdoor unit instead of two.

q Low cost installation.

q Simple control, one control station for big space.

q Option to control by wireless or wired controller.

q Ducted or cassette application.

The twin application is used mainly in big open space where the total space area is controlled one controller only for 2 units. Airwell twin design allows to connect two similar indoor units to one common outdoor unit. The two indoor units are working in a same mode and set up only once, one indoor unit used as master.

TWIN APPLICATION

Capacity combinations Indoor units Outdoor units

Twin system

KBD018 + KBD018 VLD036

KBD024 + KBD024 VLD048

KBD030 + KBD030 VLD060

Twin application

Tubing & charge instructions VLD036 VLD048 VLD060

Pipe diameter (liquid-gas) (inches) 3/8”-5/8”

Max length (m) 30 50 50

Max. difference in branch length (m) 10

Max. height drop between indoor units (m) 0.5

Max. height drop between indoor and outdoor units (m) 20

Max. branch length (m) 15

Page 28: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

28

KBDCASSETTE MONOSPLIT MULTISPLIT Q Only size 12

q Cassette line available in capacities from 3.5 to 12.5 kW.q Cooling & heating operation mode.q DC Inverter and sine wave compressor drive technology.q “I Feel” function with precise room temperature control.q Available in 3PH from 10 kW.

[ PRODUCT ADVANTAGES ]

Operating in ambient temperature, down to -15°C in heating and -15°C in cooling. Fresh air intake. Integrated water pump. Centralized controller up to 64 units (optional). Size 12 can also match to multi ODU. Twin application.

RC08B

RCW8(optional)

RCW6(optional)

OPTIONSAccessory Reference Photo Function

Wired single control RCW6for KBD 24-48

7ACEL1704 Mode, fan speed, real time, timer, temperature, weekly timer, swing and “I Feel”.

Wired single control RCW8

7ACEL1706 Mode, fan speed, timer ON/OFF, temperature, swing and “I Feel”.

Central controller 7ACEL1707Controls up to 64 indoor units with indivitual setting failure codes indication, ON-OFF dry contact, last operation memory, Modbus.

BMS gateway 7ACEL1708 Maximum 1024 units could be connected (16 gateways).

Monosplit DCI

TWIN APPLICATION

A++

FEATURES

360 DEGREE FLOW WITH ROUND CORNERS

600x600 and 900x900

FLEXY MATCH

FLEXYMATCH

DC INVERTER R410A FLUID ANTIBACTERIA FILTER

I FEEL MULTIFLOW 360° SLEEP MODE SELF DIAGNOSTIC LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

INTEGRATED WATER PUMP

TWIN APPLICATION LOW AMBIENT COOLING

- °C

LOW AMBIENT HEATING

°C-FRESH AIR BMS COMPATIBLE

BMS

Page 29: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

29

ELECTRA SOLUTIONS

KBD TECHNICAL DATAIndoor units ELSI-KBD012-N11 ELSI-KBD018-N11 ELSI-KBD024-N11 ELSI-KBD036-N11 ELSI-KCD048-N11 ELSI-KCD048-N11Outdoor units 1~230V - 50 Hz ELAU-VLD012-H11 ELAU-VLD018-H11 ELAU-VLD024-H11 ELAU-VLD036-H11 ELAU-VMD048-H11 -Outdoor units 3~400V - 50 Hz - N - - - - - ELAU-VLD048-H13

COOLINGRated capacity kW 3.5 (1.0~4.0) 5.0 (1.6~6.2) 7.2 (2.0~7.8) 10.0 (3.0~11.8) 14.0 (4.1~16.0) 12.5 (4.2~14.0)Pdesignc kW 3.5 5.0 7.2 10.0 14 -Rated power input kW 1.09 1.65 2.24 3.32 5.34 3.89SEER/Energy label 5.6/A+ 5.6/A+ 6.1/A++ 5.4/A 6.1/A++ 3.21/AOperating limits °C -15°/50° Dry bulbHEATINGRated capacity kW 3.5 (1.0~4.1) 5.3 (1.6~6.4) 8.0 (2.2~8.6) 10.5 (3.2~12.0) 15.5 (4.2~17.6) 13.0 (4.2~14.8)Pdesignh (average climate) kW 3.5 5.3 7.8 10.0 11.5 -Pdesignh (warmer climate) kW 3.5 5.3 7.8 10.5 11.8 -Rated power input kW 0.97 1.47 2.15 2.91 5.13 3.60SCOP/Energy label (average climate) 3.8/A 3.8/A 3.9/A 3.8/A 4/A+ 3.61/ASCOP/Energy Label (warmer climate) 4.8/A++ 4.8/A++ 4.6/A++ 4.4/A++ 5.1/A+++ -Operating limits °C -15°/24° Dry bulbCapacity @ -10°C kW 3.1 4.4 6.6 8.7 - 10.4Capacity @ -15°C kW 2.7 3.7 5.7 7.5 - 9.1

INDOOR UNITSound pressure level to 1 m (LS/MS/HS) dB(A) 34/38/42 33/40/48 42/45/47 46/49/51 45/49/53 47/50/54Sound power level dB(A) 55 60 62 63 64 64Airflow (LS/MS/HS) m³/h 450/530/650 500/650/800 1300/1500/1700 1400/1600/1850 1400/1600/1850 1600/1800/2200Dehumidification l/h 1.5 2 2.5 3.8 4.5 4.5Outline dimensions (WxHxD) mm 570x270x570 570x270x570 840x245x840 840x245x840 840x287x840 840x287x840Package dimensions (WxHxD) mm 675x305x675 675x305x675 900x265x900 900x265x900 900x292x900 900x292x900Net weight/Gross weight kg 16/19 16.5/19 24/28 26.5/30.5 28/32.1 29/33Part number ESP042235 ESP042241 ESP042224 ESP042226 ESP042242 ESP042242FRAMEOutline dimensions (WxHxD) mm 650x50x650 650x50x650 950x55x950 950x55x950 950x55x950 950x55x950Package dimensions (WxHxD) mm 715x123x715 715x123x715 1035x90x1035 1035x90x1035 1035x90x1035 1035x90x1035Net weight/Gross weight kg 2.5/4.5 2.5/4.5 5/8 5/8 5/8 5/8Part number frame EACVF0012 EACVF0012 EACVF0008 EACVF0008 EACVF0008 EACVF0008OUTDOOR UNITSound pressure level to 1 m dB(A) 52 55 57 60 - 61Sound power level dB(A) 62 65 69 70 72 70Airflow m³/h 2200 2500 3500 5500 6800 7200Compressor type Rotary DCI Rotary DCI Twin Rotary DCI Twin Rotary DCI Rotary DCI Twin Rotary DCIOutline dimensions (WxHxD) mm 760x590x285 845x700x320 900x860x315 990x965x345 952x1333x410 938x1369x392Package dimensions (WxHxD) mm 887x645x355 965x755x395 1043x915x395 1120x1100x435 1095x500x1470 1095x1505x495Net weight/Gross weight kg 35.4/37.9 46/50 59/63 73/83 95.1/108.4 102.5/116

Part number 1~230V - 50 Hz ESP062821 ESP062822 ESP062823 ESP062825 ESP062831 -

Part number 3~400V - 50 Hz - N - - - - - ESP062826

POWER SUPPLY 1~230V - 50 HZPower supply side Outdoor Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor -Power cable section mm² 3x1.5 3x1.0+3x2.5 3x1.0+3x2.5 3x1.0+3x4.0 3x1.0 + 3x4.0 -Fuse rating am A 16 10+16 10+20 10+30 10 + 40 -Electrical connections mm² 4x1.0 3x0.5 3x0.5 3x0.5 2x0.5 -POWER SUPPLY 3~400V - 50 HZ - NPower supply side - - - - - Indoor & OutdoorPower cable section mm² - - - - - 3x1.0+5x2.5Fuse rating am A - - - - - 10+25Electrical connections mm² - - - - - 3x0.5PIPE LINESuction pipe diameter inches 3/8” 1/2” 5/8” 5/8” 5/8” 5/8”Liquid pipe diameter inches 1/4” 1/4” 3/8” 3/8” 3/8” 3/8”Max length m 20 30 50 65 65 65Max height m 10 20 25 30 30 30

IDU Compatible with ODU

Cassette ODU single ODU multi

KBD 12 VLD VCZ

KBD 18 VLD

KBD 24 to 48 VLD

Page 30: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

30

KBFON/OFF CASSETTE 900X900

[ PRODUCT ADVANTAGES ]

Compact and slim design from 245 mm (model 48). Integrated electronic control box. Fresh air intake.

q Cassette line available in capacities from 12.8 up to 14 kW.q Cooling and heating operation mode.q “I Feel” function with precise room temperature control.

RCW8(optional)

RC08B

OPTIONSAccessory Reference Photo Function

Wired single control RCW8

7ACEL1706 Mode, fan speed, timer ON/OFF, temperature, swing and “I Feel”.

Central controller 7ACEL1707Controls up to 64 indoor units with indivitual setting failure codes indication, ON-OFF dry contact, last operation memory, Modbus.

BMS gateway 7ACEL1708 Maximum 1024 units could be connected (16 gateways).

Fixed Speed

Central controller (optional)

FEATURES

360 DEGREE FLOW WITH ROUND CORNERS

G

OOD QUALITY

PRICE RATIOFIXED SPEEDFIXED SPEED

R410A FLUID ANTIBACTERIA FILTER

I FEEL MULTIFLOW 360° SLEEP MODE DIGITAL DISPLAY PROGRAMMABLE TIMER

24 H

SELF DIAGNOSTIC LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

INTEGRATED WATER PUMP

ALARM OUTPUT UNIT ON INPUT

UNITON

FRESH AIR BMS COMPATIBLE

BMS

Page 31: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

31

ELECTRA SOLUTIONS

KBF TECHNICAL DATAIndoor units ELSI-KBF024-N11 ELSI-KBF036-N11 ELSI-KBF048-N11

Outdoor units 1-230V - 50 Hz ELAU-VOF024-H11 ELAU-VOF036-H11 -

Outdoor units 3-400V - 50 Hz - - ELAU-VOF048-H13

COOLINGRated capacity kW 6.8 10 12.8

Input power kW 2.61 3.97 4.77

EER/Energy label 2.61/D 2.52/E 2.68/D

Operating limits °C 18°/43° Dry bulb

HEATINGRated capacity kW 7.4 11 13.6

Input power kW 2.49 3.57 4.65

COP/Energy label 2.97/D 3.08/D 2.92/D

Operating limits °C -7°/24° Dry bulb

INDOOR UNITSound pressure level to 1 m (LS/MS/HS) dB(A) 42/45/48 43/47/51 46/49/54

Sound power level dB(A) 58 61 64

Airflow (LS/MS/HS) m³/h 900/1050/1200 1400/1600/1800 1400/1600/1900

Dehumidification l/h 2.4 2.9 4.3

Outline dimensions (WxHxD) mm 840x205x840 840x245x840 840x245x840

Package dimensions (WxHxD) mm 900x225x900 900x265x900 900x265x900

Net weight/Gross weight kg 23/27 25/28.5 26.5/30.2

Part number ESP042200 ESP042201 ESP042202

FRAME (INCLUDED IN THE INDOOR UNIT)Outline dimensions (WxHxD) mm 950x55x950 950x55x950 950x55x950

Package dimensions (WxHxD) mm 1035x90x1035 1035x90x1035 1035x90x1035

Net weight/Gross weight kg 5/8 5/8 5/8

Part number frame 950x950 EACVF0012 EACVF0008 EACVF0008

OUTDOOR UNITSound pressure level to 1 m dB(A) 59 61 62

Sound power level dB(A) 69 71 72

Airflow m³/h 2700 5500 7200

Compressor type Rotary Scroll Scroll

Outline dimensions (WxHxD) mm 845x700x320 990x965x345 938x1369x392

Package dimensions (WxHxD) mm 965x755x395 1120x1100x435 1095x1505x495

Net weight/Gross weight kg 48/54.5 84.5/94.5 110/124

Part number 1~230V - 50 Hz ESP062759 ESP062761 -

Part number 3~400V - 50 Hz - - ESP062763

POWER SUPPLY 1~230V - 50 HZPower supply side Indoor Indoor -

Power cable section mm² 3x2.5 3x4.0 -

Fuse rating am A 25 30 -

Electrical connections mm² 3x2.5 + 3x1.0 + 2x0.5

3x4.0 + 3x1.0 + 2x0.5 -

POWER SUPPLY 3~400V - 50 HZPower supply side - - Indoor & Outdoor

Power cable section mm² - - 3x1.0 + 5x2.5

Fuse rating am A - - 16 + 20

Electrical connections mm² - - 3x0.5

PIPE LINESuction pipe diameter inches 5/8” 3/4” 3/4”

Liquid pipe diameter inches 3/8” 3/8” 3/8”

Max length m 25 30 50

Max height m 15 20 25

IDU Compatible with ODU

Cassette ODU single

KBF 24 to 36 VOF

CBD 48 & 60 VOF

Page 32: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

32

[ MODEL NAME ] Page18

5 kW24

7 kW36

10 kW48

12.5 kW60

16 kW

FLOOR CEILING MONOSPLIT TBD 34

Flo

or

Cei

ling

Ran

ge

Page 33: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

33

[ MODEL NAME ] Page18

5 kW24

7 kW36

10 kW48

12.5 kW60

16 kW

FLOOR CEILING MONOSPLIT TBD 34

Page 34: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

34

up to 11 m

TBDFLOOR CEILING MONOSPLIT

[ PRODUCT ADVANTAGES ]

Operating in ambient temperature, down to -15°C in heating and -15°C in cooling. Centralized controller up to 64 units (optional). Fresh air intake option. 4 dimensional airflow for maximum comfort.

q Floor ceiling line available in capacities from 5.3 to 15.6 kW.q Cooling & heating operation mode.q DC Inverter and sine wave compressor drive technology.q “I Feel” function with precise room temperature control.q Available in 3PH from 10 kW.

RCW8(optional)

RCW6(optional)

A++

RC08B

FEATURES

OPTIONSAccessory Reference Photo Function

Wired single control RCW6

7ACEL1704Mode, fan speed (except for size 60), real time, timer, temperature, weekly timer, swing and “I Feel”.

Wired single control RCW8 for TBD 18-48

7ACEL1706 Mode, fan speed, timer ON/OFF, temperature, swing and “I Feel”.

Central controller 7ACEL1707Controls up to 64 indoor units with indivitual setting failure codes indication, ON-OFF dry contact, last operation memory, Modbus.

BMS gateway 7ACEL1708 Maximum 1024 units could be connected (16 gateways).

4 DIMENSIONAL AIRFLOWS FOR MAXIMUM COMFORT

“I FEEL” FUNCTION

DC INVERTER R410A FLUID ELECTRONIC EXPANSION VALVE

ANTIBACTERIA FILTER

FRESH AIR I FEEL SLEEP MODE DIGITAL DISPLAY PROGRAMMABLE TIMER

24 H

SELF DIAGNOSTIC LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

LEFT/RIGHT DRAIN CONNEXION

ALARM OUTPUT UNIT ON INPUT

UNITON

DRY CONTACT ON/OFF

LOW AMBIENT COOLING

- °C

LOW AMBIENT HEATING

°C-WATER PUMP

(OPTION)BMS COMPATIBLE

BMS

Monosplit DCI

Page 35: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

35

Indoor units ELSI-TBD018-N11

ELSI-TBD024-N11

ELSI-TBD036-N11

ELSI-TCD048-N11

ELSI-TCD048-N11

ELSI-TBD060-N11

Outdoor units 1~230V - 50 Hz ELAU-VLD018-H11

ELAU-VLD024-H11

ELAU-VLD036-H11

ELAU-VMD048-H11 - -

Outdoor units 3~400V - 50 Hz - N - - - - ELAU-VLD048-H13

ELAU-VLD060-H13

COOLINGRated capacity kW 5.3 (1.5~6.4) 7.2 (2.0~7.8) 10.5 (3.2~11.8) 14.0 (4.1~16.4) 14.0 (4.5~15.2) 15.6 (5.0~17.5)

Pdesignc kW 5.3 7.2 10.5 14 - -

Rated power input kW 1.63 2.24 3.48 5.34 4.36 4.86

SEER/Energy label 6.1/A++ 6.4/A++ 6.0/A+ 6.1/A++ 3.21/A 3.21/A

Operating limits °C -15°/50° Dry bulb

HEATINGRated capacity kW 5.9 (1.6~7.0) 7.8 (2.0~8.6) 11 (3.2~12.5) 16.4 (4.4~18.4) 14.6 (4.8~15.8) 17 (5.5~18.6)

Pdesignh (average climate) kW 5.3 7.8 10.2 11.8 - -

Pdesignh (warmer climate) kW 5.3 7.8 10.5 11.8 - -

Rated power input kW 1.49 2.10 3.05 5.43 4.04 4.70

SCOP/Energy label (average climate) 3.8/A 3.9/A 3.8/A 4/A+ 3.61/A 3.61/A

SCOP/Energy label (warmer climate) 4.8/A++ 4.6/A++ 4.4/A++ 5.1/A+++ - -

Operating limits °C -15°/24° Dry bulb

Capacity @ -10°C kW 4.3 7 8.3 - 11.6 12.7

Capacity @ -15°C kW 3.7 6 7.2 - 10 11

INDOOR UNITSound pressure level to 1 m (LS/MS/HS) dB(A) 38/41/44 46/50/52 43/49/52 41/46/52 51/54/57 51/54/57

Sound power level dB(A) 60 63 65 66 68 69

Airflow (LS/MS/HS) m³/h 600/750/900 1100/1250/1400 1500/1850/2200 1400/1800/2100 1700/1900/2300 1700/1900/2300

Dehumidification l/h 2 2.3 3.5 3.5 4.5 5.0

Outline dimensions (WxHxD) mm 1068x675x235 1068x675x235 1650x675x235 1650x675x235 1650x675x235 1650x675x235

Package dimensions (WxHxD) mm 1145x755x313 1145x755x313 1725x755x313 1725x755x313 1725x755x313 1725x755x313

Net weight/Gross weight kg 25/31.5 25/30 40/46 40/46 38.2/44.6 43/50

Part number ESP012225 ESP022998 ESP023000 ESP023003 ESP023003 ESP023002

OUTDOOR UNITSound pressure level to 1 m dB(A) 55 57 60 - 61 61

Sound power level dB(A) 65 69 70 72 70 70

Airflow m³/h 2500 3500 5500 6800 7200 7500

Compressor type Rotary DCI Twin Rotary DCI Twin Rotary DCI Rotary DCI Twin Rotary DCI Twin Rotary DCI

Outline dimensions (WxHxD) mm 845x700x320 900x860x315 990x965x345 952x1333x410 938x1369x392 938x1369x392

Package dimensions (WxHxD) mm 965x755x395 1043x915x395 1120x1100x435 1095x500x1470 1095x1505x495 1095x1505x495

Net weight/Gross weight kg 46/50 59/63 73/83 95.1/108.4 102.5/116 102.5/116

Part number 1~230V - 50 Hz ESP062822 ESP062823 ESP062825 ESP062831 - -

Part number 3~400V - 50 Hz - N - - - - ESP062826 ESP062829

POWER SUPPLY 1~230V - 50 HZPower supply side Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor - -

Power cable section mm² 3x1.0+3x2.5 3x1.0+3x2.5 3x1.0+3x4.0 3x1.0 + 3x4.0 - -

Fuse rating am A 10+16 10+20 10+30 10 + 40 - -

Electrical connections mm² 3x0.5 3x0.5 3x0.5 2x0.5 - -

POWER SUPPLY 3~400V - 50 HZ - NPower supply side - - - - Indoor & Outdoor Indoor & Outdoor

Power cable section mm² - - - - 3x1.0+5x2.5 3x1.0+5x2.5

Fuse rating am A - - - - 10+25 10+25

Electrical connections mm² - - - - 3x0.5 3x0.5

PIPE LINESuction pipe diameter inches 1/2” 5/8” 5/8” 5/8” 5/8” 3/4”

Liquid pipe diameter inches 1/4” 3/8” 3/8” 3/8” 3/8” 3/8”

Max length m 30 50 65 65 65 65

Max height m 20 25 30 30 30 30

TBD TECHNICAL DATA

ELECTRA SOLUTIONS IDU Compatible with ODU

Floor ceiling ODU single

TBD 18 & 24 VLD

TBD 36 VLD

TBD 48 & 60VLD

Page 36: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

36

[ MODEL NAME ] kW Btu/hMax. num. of indoors Page

[ RESIDENTIAL INDOOR UNITS ]High wall

JKD 09/12/18DuctedOCD 12

CassetteKBD 12

RE

SID

EN

TIA

L LI

NE

VCZ2-18 5.2 18 000 2 38 & 40

VCZ3-27 7.8 26 500 3 38 & 40

VCZ4-30 8.2 30 000 4 38 & 41

Mul

tisp

lit D

CI R

ang

eC

ombi

natio

n Ta

ble

Page 37: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

37

[ MODEL NAME ] kW Btu/hMax. num. of indoors Page

[ RESIDENTIAL INDOOR UNITS ]High wall

JKD 09/12/18DuctedOCD 12

CassetteKBD 12

RE

SID

EN

TIA

L LI

NE

VCZ2-18 5.2 18 000 2 38 & 40

VCZ3-27 7.8 26 500 3 38 & 40

VCZ4-30 8.2 30 000 4 38 & 41

Page 38: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

38

VCZRESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO

[ PRODUCT ADVANTAGES ]

Same indoor for multi and single application. Option to connect limited indoor units (total capacity >100% of rated capacity) and extend after installation. Design for long tubing distance installation.

q Multi line available in 3 capacities from 5.2 up to 8.5 kW.q DC Inverter and sine wave compressor drive technology.q Match with high wall, ducted and cassette indoor units.

A++

FEATURES

FLEXY MATCH

FLEXYMATCH

R410A FLUID ELECTRONIC EXPANSION VALVE

AUTO CLEAN/DRY

AUTO

I FEEL SLEEP MODE DIGITAL DISPLAY TURBO MODE

TURBO

PROGRAMMABLE TIMER

24 H

SELF DIAGNOSTIC LOW BATTERY INDICATION

RESTART

AUTO RESTART (MEMORY)

REMOTE CONTROL LOCK

LOW AMBIENT COOLING

- °C

LOW AMBIENT HEATING

°C-

Multisplit DCI

HIGH WALL JKD 9/12/18

COMPATIBLEWITH

DUCTED OCD 12

CASSETTE KBD 12

Page 39: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

39

Outdoor units ELAU-VCZ218-H11 ELAU-VCZ327-H11 ELAU-VCZ430-H11

OUTDOOR UNIT

Cooling

Rated capacity kW 5.2 7.8 8.5

Pdesignc kW 5.2 7.8 8.5

Rated power input kW 1.62 2.43 2.65

SEER/Energy label 6.1/A++ * 6.6/A++ * 6.6/A++ *

Operating limits °C -15°/50° Dry bulb

Heating

Rated capacity kW 6.0 8.5 9.0

Pdesignh (average climate) kW 5.9 8.0 8.2

Pdesignh (warmer climate) kW 6.0 8.0 8.2

Rated power input kW 1.66 2.31 2.36

SCOP/Energy label (average climate) 4.1/A+ 3.9/A 3.9/A

SCOP/Energy label (warmer climate) 4.8/A++ 4.6/A++ 4.6/A++

Operating limits °C -15°/24° Dry bulb

Capacity @ -10°C kW 4.5 6.5 6.6

Capacity @ -15°C kW 4 5.7 5.8

Sound pressure level to 1 m dB(A) 55 58 58

Sound power level dB(A) 65 68 70

Airflow m³/h 2500 3500 3800

Compressor type Twin Rotary DC Inverter Twin Rotary DC Inverter Twin Rotary DC Inverter

Outline dimensions (WxHxD) mm 845x700x320 900x860x315 900x860x315

Package dimensions (WxHxD) mm 965x755x395 1043x915x395 1043x915x395

Net weight/Gross weight kg 48/52 62/67 65/69

Part number ESP091163 ESP091164 ESP091165

POWER SUPPLY 1~230V - 50 HZ

Power supply side Outdoor Outdoor Outdoor

Power cable section mm² 3x2.5 3x2.5 3x2.5

Fuse rating am A 25 25 25

Electrical connections mm² 2 (4x1.0) 3 (4x1.0) 4 (4x1.0)

PIPE LINE

Suction pipe diameter inches 2x3/8” 3x3/8” 4x3/8”

Liquid pipe diameter inches 2x1/4” 3x1/4” 4x1/4”

Max length m 30 45 60

Max length per circuit m 20 25 30

Max height between indoor and oudoor units

ODU higher than IDU m 10 10 10

ODU lower than IDU m 15 15 15

Max height between indoor units m 10 10 10

* A++ for JKD 9 x 3 combinations.

VCZ TECHNICAL DATA

ELECTRA SOLUTIONS

Page 40: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

40

VCZ3-27RESIDENTIAL MULTISPLIT TRIO

Indoor unitscombinations

COOLING HEATING

Rated capacity (kW) Total capacity (kW) Total input power (kW) EER/Energy label

Rated capacity (kW) Total capacity (kW) Total input power (kW) COP/Energy labelUnit A Unit B Rated Min. Max. Rated Min. Max. Unit A Unit B Rated Min. Max. Rated Min. Max.

9+9 2.60 2.60 5.20 1.80 6.20 1.62 0.55 2.09 3.21/A 3.00 3.00 6.00 2.00 6.50 1.66 0.58 1.81 3.61/A

9+12 2.23 2.97 5.20 1.80 6.30 1.62 0.55 2.09 3.21/A 2.57 3.43 6.00 2.00 6.50 1.66 0.58 1.81 3.61/A

9+18 1.73 3.47 5.20 1.80 6.70 1.62 0.55 2.15 3.21/A 2.00 4.00 6.00 2.00 6.80 1.66 0.58 1.89 3.61/A

12+12 2.60 2.60 5.20 1.80 6.70 1.62 0.55 2.15 3.21/A 3.00 3.00 6.00 2.00 6.80 1.66 0.58 1.89 3.61/A

Based on wall mounted combination

Indoor unitscombinations

COOLING HEATING

Rated capacity (kW) Total capacity (kW) Total input power (kW) EER/Energy label

Rated capacity (kW) Total capacity (kW) Total input power (kW) COP/Energy labelUnit A Unit B Unit C Rated Min. Max. Rated Min. Max. Unit A Unit B Unit C Rated Min. Max. Rated Min. Max.

9+9 2.65 2.65 - 5.30 1.80 6.60 1.55 0.61 2.08 3.42/A 2.80 2.80 - 5.60 1.45 7.40 1.54 0.48 2.41 3.64/A

9+12 2.65 3.54 - 6.19 1.80 7.70 1.85 0.61 2.43 3.35/A 2.80 3.70 - 6.50 1.68 8.50 1.79 0.55 2.76 3.63/A

12+12 3.54 3.54 - 7.08 1.80 8.80 2.17 0.61 2.78 3.26/A 3.70 3.70 - 7.40 1.92 9.60 2.05 0.62 3.12 3.61/A

9+18 2.65 5.00 - 7.65 1.84 9.40 2.37 0.64 2.97 3.23/A 2.80 5.50 - 8.30 2.15 10.00 2.30 0.64 3.25 3.61/A

12+18 3.12 4.68 - 7.80 1.88 9.50 2.43 0.64 3.00 3.21/A 3.40 5.10 - 8.50 2.20 10.00 2.36 0.64 3.25 3.60/A

18+18 3.90 3.90 - 7.80 1.88 9.60 2.43 0.64 3.03 3.21/A 4.25 4.25 - 8.50 2.20 10.50 2.36 0.64 3.41 3.60/A

9+9+9 2.60 2.60 2.60 7.80 1.88 9.50 2.43 0.64 3.00 3.21/A 2.83 2.83 2.83 8.50 2.20 10.00 2.31 0.64 3.25 3.68/A

9+9+12 2.34 2.34 3.12 7.80 1.88 9.55 2.43 0.64 3.02 3.21/A 2.55 2.55 3.40 8.50 2.20 10.20 2.31 0.64 3.32 3.68/A

9+9+18 1.95 1.95 3.90 7.80 1.88 9.60 2.43 0.64 3.03 3.21/A 2.13 2.13 4.25 8.50 2.20 10.50 2.31 0.64 3.41 3.68/A

9+12+12 2.13 2.84 2.84 7.80 1.88 9.55 2.43 0.64 3.02 3.21/A 2.32 3.09 3.09 8.50 2.20 10.50 2.31 0.64 3.41 3.68/A

9+12+18 1.80 2.40 3.60 7.80 1.88 9.60 2.43 0.64 3.03 3.21/A 1.96 2.62 3.92 8.50 2.20 10.50 2.31 0.64 3.41 3.68/A

12+12+12 2.60 2.60 2.60 7.80 1.88 9.60 2.43 0.64 3.03 3.21/A 2.83 2.83 2.83 8.50 2.20 10.50 2.31 0.64 3.41 3.68/A

Based on wall mounted combination

VCZ2-18RESIDENTIAL MULTISPLIT DUOCAPACITY COMBINATION

CAPACITY COMBINATION

Multisplit DCI

HIGH WALL JKD 9/12/18

COMPATIBLEWITH

DUCTED OCD 12

CASSETTE KBD 12

Page 41: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

41

VCZ4-30RESIDENTIAL MULTISPLIT QUATTRO

Indoor unitscombinations

COOLING HEATING

Rated capacity (kW) Total capacity (kW) Total input power (kW) EER/Energy label

Rated capacity (kW) Total capacity (kW) Total input power (kW) COP/Energy labelUnit A Unit B Unit C Unit D Rated Min. Max. Rated Min. Max. Unit A Unit B Unit C Unit D Rated Min. Max. Rated Min. Max.

9+9 2.65 2.65 - - 5.30 1.80 6.60 1.53 0.58 2.24 3.46/A 2.80 2.80 - - 5.60 1.43 7.40 1.57 0.53 2.40 3.57/B

9+12 2.65 3.54 - - 6.19 1.80 7.10 1.82 0.58 2.41 3.40/A 2.80 3.70 - - 6.50 1.66 8.50 1.80 0.60 2.75 3.61/A

12+12 3.54 3.54 - - 7.08 1.80 7.60 2.13 0.58 2.58 3.32/A 3.70 3.70 - - 7.40 1.89 9.60 2.05 0.66 3.11 3.61/A

9+18 2.65 5.00 - - 7.65 1.80 9.40 2.33 0.58 3.20 3.28/A 2.80 5.50 - - 8.30 2.12 10.20 2.29 0.66 3.30 3.62/A

12+18 3.40 5.10 - - 8.50 2.00 10.00 2.65 0.58 3.40 3.21/A 3.40 5.10 - - 8.50 2.17 10.50 2.35 0.66 3.40 3.62/A

18+18 4.25 4.25 - - 8.50 2.00 10.00 2.65 0.58 3.40 3.21/A 4.50 4.50 - - 9.00 2.30 10.50 2.48 0.66 3.40 3.63/A

9+9+9 2.65 2.65 2.65 - 7.95 1.87 9.50 2.44 0.60 3.23 3.26/A 2.83 2.83 2.83 - 8.50 2.17 10.50 2.28 0.66 3.40 3.73/A

9+9+12 2.55 2.55 3.40 - 8.50 2.00 10.00 2.65 0.60 3.40 3.21/A 2.70 2.70 3.60 - 9.00 2.30 10.50 2.42 0.66 3.40 3.72/A

9+9+18 2.13 2.13 4.25 - 8.50 2.00 10.00 2.65 0.60 3.40 3.21/A 2.25 2.25 4.50 - 9.00 2.30 10.50 2.42 0.66 3.40 3.72/A

9+12+12 2.32 3.09 3.09 - 8.50 2.00 10.00 2.65 0.60 3.40 3.21/A 2.45 3.27 3.27 - 9.00 2.30 10.50 2.42 0.66 3.40 3.72/A

9+12+18 1.96 2.62 3.92 - 8.50 2.00 10.00 2.65 0.60 3.40 3.21/A 2.08 2.77 4.15 - 9.00 2.30 10.50 2.42 0.66 3.40 3.72/A

12+12+12 2.83 2.83 2.83 - 8.50 2.00 10.00 2.65 0.60 3.40 3.21/A 3.00 3.00 3.00 - 9.00 2.30 10.50 2.42 0.66 3.40 3.72/A

9+9+9+9 2.13 2.13 2.13 2.13 8.50 2.00 10.00 2.65 0.64 3.40 3.21/A 2.25 2.25 2.25 2.25 9.00 2.30 10.50 2.36 0.66 3.40 3.81/A

9+9+9+12 1.96 1.96 1.96 2.62 8.50 2.00 10.00 2.65 0.64 3.40 3.21/A 2.08 2.08 2.08 2.77 9.00 2.30 10.50 2.36 0.66 3.40 3.81/A

Based on wall mounted combination

CAPACITY COMBINATION

Page 42: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

42

Unique solutions

Twin application

Page 43: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

Uni

que

so

luti

ons

43

Suction twin branch: 7ACFH0476

Liquid twin branch: 7ACFH0477

A

q Twin application with ducted OCD, see page 48.

q Twin application with cassette KBD, see page 60.

TWIN APPLICATION

The most cost saving solution for single-area spaces:

q Simple installation by having one refrigerant and control system.

q Space saving by using one outdoor unit instead of two.

q Low cost installation.

q Simple control, one control station for big space.

q Option to control by wireless or wired controller.

q Ducted or cassette application.

The twin application is used mainly in big open space where the total space area is controlled one controller only for 2 units. Airwell twin design allows to connect two similar indoor units to one common outdoor unit. The two indoor units are working in a same mode and set up only once, one indoor unit used as master.

Twin application

Page 44: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

44

Page 45: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

45

Page 46: 2016/2017 - · PDF file2016/2017 Air conditioning. 2 Contact Us An international sales network ... TECHNICAL SUPPORT E-mail: technical-spfr@airwell-res.com Tel: +33 (0)1 76 21 82 95

3, AVENUE DU CENTRE, LES QUADRANTS, BÂT. A - 78280 GUYANCOURT, FRANCE TEL.: +33 (0)1 76 21 82 00 - FAX: +33 (0)1 76 21 82 01 - www.electra-res.com - www.airwell-residential.com

RAC-

E GB

201

6 -

Spec

ifica

tions

sub

ject

to c

hang

e w

ithou

t not

ice.

Pic

ture

s no

n co

ntra

ctua

l. Pr

inte

d in

UE.

Our Aftersales Service

Tel. +33 (0)1 76 21 82 95

SPARE PARTS ORDERS:e-mail [email protected]

TECHNICAL SUPPORT:e-mail [email protected]

Export