www.raytest.com
ɣ-RADIATION Choose your application of
99mTc 0 – 200 keV
131I 200 – 700 keV
59Fe 700 – 2.600 keV
ɣ-HPLC ml / min
GABI
1x1" NaI(Tl)
pin hole
GABI
2x2" NaI(Tl)
pin hole
miniGITA
BGO
GITA BGO
ISOMED
MUCHA
2x2" NaI(Tl)
MUCHA
1x1" NaI(Tl)
GABI
3x3" NaI(Tl)
pin hole
MUCHA
3x3" NaI(Tl)Counting
Dose Calibrator
TLC 2x 50 x 200 mm
TLC 1x 50 x 200 mm
γ
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com48 |
GABI Star is the latest technology µ- processor controlled counter with built in digital ratemeter.
GABI Star stand alone unit offers a keyboard and liquid crystal display for parameter dialog, entry and result presentation.
GABI Star has a high voltage unit for manual or preset selection of the required detector operation.
GABI Star has 2 simultaneous counting channels with each 2 individually selectable energy thresholds each for setting an individual counting window for a particular nuclide.
GABI Star is counting the radiation events in an energy chan-nel per selected interval time.
The information of counts per time can be transferred to a ra-temeter, which converts the digital format to an analog output format of 0 – 1V. Individual parameters of the ratemeter can be selected and entered by LCD and keyboard. The output si-gnal 0 – 1V of GABI Star can be easily adapted to the required chromatography conditions. GABI Star has an extremely high dynamic range from 0 – 600.000 c/s.
The information of counts per time is transferred to a PC run-ning GINA Star program. The chromatogram is displayed live on screen. No overriding of ranges can happen.
Peak integration, background subtraction, flow correction, absolute activity calculation etc can be performed manually or automatically. Limit-of-detection is determined for every ROI, displayed and printed. GINA Star program can control all modules of Agilent HPLC. All data and parameters are stored under one identity code. GINA Star can be installed as well in background of the original HPLC-operation program and the user can use the operation program of the HPLC supplier as well as the advantages of GINA Star.
125I Iodine radio-HPLC
99mTc Technetium
2 simultaneous counting channels
free threshold settings
extremely high dynamic range 0 – 600.000 c/s
LCD 4 lines, 20 characters each
keybord: 16 touch sensitive keys
output: 0 – 1 V
GABI Star radioactivity-HPLC-flow monitor, 1x1" NaI scintillation detector
GABI Star 1" pin-hole
energy calibration with 137Cs
TECHNICAL DATA ORDERING INFORMATION
γ
GABI Star
energy range: 30 – 1600 keV
high voltage range: 500 – 2000 V
count rate: 0 – 600.000 c/s
data input: 7 analog input channels, -0.5 to + 4.5V resolution 21 bit
data output: RS 232 C, 2 analog outputs 0 - 1 V resolution 20 bit
scintillation probe: 1"
Nal-scintillator: 1x1", pin-hole 8 mm diam. x 20 mm deep
housing: 39 mm ø stainless steel
window: 20 mg / cm2
shielding: lead 30 mm wall
flow cell: 100 µl coiled, thin plastic tube
01050100 GABI Star ɣ- HPLC-flow-detector
with keyboard and display analog output 0 – 1V
01052005 GABI Star scintillation detector 1 x 1" Nal scintillation low energy ɣ-probe window 200 mg / cm2
01052015 GABI Star 30 mm lead shielding for 1“ detector
option
PC + Windows program
01240012 GINA Star 4-channel program 2 radioactivity channel 2 other detectors input
01058007 ɣ- reference standard
01240074 installation
01240074 installation GABI Star stand alone
01240239 training GABI Star stand alone
01240218 installation GABI Star with GINA Star
01240220 training GABI Star with GINA Star
HPLC with 99mTc pin-hole scintillation detectorɣ-spectrum 99mTc
Integration N:\Helfer\GABI Star 1-Zoll Bohrloch (Mainz)\TC-99M Spektrum\140704_01
Start: 04.07.2014 08:44
100 200 300 400 500 600 700 keV
ChA
100 200 300 400 500 600 700 keV
0,0
2,0
4,0
6,0
8,0
10,0
12,0
14,0
16,0
18,0
20,0 CPS *1000
141 keV
Probenbeschreibung
Messung: 140704_01, Injektion : 04.07.2014 08:44
Methode: TC-99M Spektrum vom: 03.07.2014 13:11
Meßstation: 12
1" Bohrlochdetektor
Radioaktivitätsdetektor: raytest Gabi Star Serien Nr..: #27384 raytest GINA star 20.04.09
Firmware V4.8
Gabi Star Quadratisch-Durchflußzelle #0
Software Version: 5.9, Service Pack 9, Build 5079
Integration ChA
Substanz Ret Typ Fläche %Fläche
keV CPS*keV %
141 keV 121,55 BB(M) 356764,6 100,00
Summe in ROI 356764,6 100,00
Fläche (total) 381433,4
Ext. BKG. 0,00 CPS
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com50 |
radioactivity HPLC
100 – 700 keV, 2x2" NaI(TL)
GABI Starradioactivity-HPLC-flow-monitor, 2x2" NaI scintillation detector
automatic energy calibration
2 simultaneous counting channels
free threshold settings
extremely high dynamic range 0 – 600.000 c/s
output: 0 – 1 V analog output
digital communication to PC
including GINA Star program
live record on PC screen
no range overriding
peak integration, manual or automatic
limit-of-detection calculation
statistical accurcy for every integral
GABI Star is the latest technology µ- processor controlled counter with built in digital ratemeter.
GABI Star stand alone unit offers a keyboard and liquid crystal display for parameter dialog, entry and result presentation.
GABI Star has a high voltage unit for manual or preset selection of the required detector operation.
GABI Star has 2 simultaneous counting channels with each 2 individually selectable energy thresholds each for setting an individual counting window for a particular nuclide.
GABI Star is counting the radiation events in an energy chan-nel per selected interval time.
The information of counts per time is transferred to a rateme-ter, which converts the digital format to an analog output for-mat of 0 – 1 V. Individual parameters of the ratemeter can be selected and entered by LCD and keyboard. The output signal 0 – 1 V of GABI Star can be easily adapted to the required chromatography conditions. GABI Star has an extremely high dynamic range from 0 – 600.000 c/s.
Alternatively:
The information of counts per time is transferred to a PC run-ning GINA Star program. The chromatogram is displayed live on screen. No overriding of ranges can happen.
Peak integration, background subtraction, flow correction, absolute activity calculation etc can be performed manually or automatically. Limit-of-detection is determined for every ROI, displayed and printed. GINA Star program can control all modules of Agilent HPLC. All data and parameters are stored under one identity code. GINA Star can be installed as well in background of the original HPLC-operation program and the user can use the operation program of the HPLC supplier as well as the advantages of GINA Star.
GABI Star 2" pin-hole
Integration H:\GD\Mucha 2 Zoll Pinhole Mainz\Tc-99m\140402_03 Start: 02.04.2014 12:46
0 100 200 300 400 500 600 700 keV
Tr1
0 100 200 300 400 500 600 700 keV
0
100
200
300
400
500
600
700
800
CPS/keV
140,keV
Probenbeschreibung
Messung: 140402_03, gestartet: 02.04.2014 12:46
Methode: Tc-99m vom: 02.04.2014 12:45
Aktivität: ,017 MBq zum Referenz Zeitpunkt: 02.04.2014 11.46
Aktivität in 1 mL Lösung; gemessen im GC-Gläschen
Software Version: 5.9, Service Pack 9, Build 5079
Integration Tr1
Substanz Ret Typ Fläche %Fläche
keV cps %
140,keV 154,00 BB(M) 23743,16 100,00
Summe in ROI 23743,16 100,00
Fläche (total) 26441,64
Ext. BKG. 0,00 CPS/keV
ɣ-spectrum of 99mTc
TECHNICAL DATA ORDERING INFORMATION
γ
01050100 GABI Star ɣ- HPLC-flow-detector
with keyboard and display
0 – 1 V analog output
digital output to PC
01059025 GABI Star scintillation probe 2x2" pin-hole, 16 x 30 mm
01059024 GABI Star 50 mm lead shielding
01059023 GABI Star flow cell 2x2" pin-hole
01058004 ɣy- reference source, 137Cs for 2x2", 3,7 kBq
option
PC + Windows program
0124012 GINA 4-channel programm incl. manual evaluation
01058007 ɣ- reference standard
01240074 installation
01240074 installation GABI Star stand alone
01240239 training GABI Star stand alone
01240218 installation GABI Star with GINA Star
01240220 training GABI Star with GINA Star
ɣ-spectrum 137Cs, reference standard ɣ-spectrum 18F
GABI*
energy range: 30 – 1600 keV high voltage range: 500 – 2000 V count rate: 0 – 500.000 c/s
data input: 7 analog input channels, -0.5 to + 4.5 V resolution 21 bit
data output: RS 232 C, 2 analog outputs 0 - 1 V resolution 20 bit
SCINTILLATION PROBES
NaI(Tl) size: 2 x 2"
pin hole size: 15 mm diameter 30 mm deep
energy range: 100 – 700 keV
typical nuclide: 18F, 99mTc
shielding: 50 mm lead
Integration H:\GD\Mucha 2 Zoll Pinhole Mainz\I-131\140402_05 Start: 02.04.2014 14:20
0 200 400 600 800 keV
Tr1
0 200 400 600 800 keV
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
2122 CPS/keV
Reg #1
Probenbeschreibung
Messung: 140402_05, gestartet: 02.04.2014 14:20
Methode: I-131 vom: 02.04.2014 14:20
Aktivität: ,005 MBq zum Referenz Zeitpunkt: 02.04.2014 11.46
Aktivität in 1 mL Lösung; gemessen im GC-Gläschen
Software Version: 5.9, Service Pack 9, Build 5079
Integration Tr1
Substanz Ret Typ Fläche %Fläche
keV cps %
Reg #1 388,00 BB(M) 862,7509 100,00
Summe in ROI 862,7509 100,00
Fläche (total) 1824,8634
Ext. BKG. 0,00 CPS/keV
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com52 |
GABI Star is the latest technology µ- processor controlled counter with built in digital ratemeter.
GABI Star stand alone unit offers a keyboard and liquid crystal display for parameter dialog, entry and result presentation.
GABI Star has a high voltage unit for manual or preset selection of the required detector operation.
GABI Star has 2 simultaneous counting channels with each 2 individually selectable energy thresholds each for setting an individual counting window for a particular nuclide.
GABI Star is counting the radiation events in an energy chan-nel per selected interval time.
The information of counts per time is transferred to a rateme-ter, which converts the digital format to an analog output for-mat of 0 – 1 V. Individual parameters of the ratemeter can be selected and entered by LCD and keyboard. The output signal 0 – 1 V of GABI Star can be easily adapted to the required chromatography conditions. GABI Star has an extremely high dynamic range from 0 – 600.000 c/s.
Alternatively:
The information of counts per time is transferred to a PC run-ning GINA Star program. The chromatogram is displayed live on screen. No overriding of ranges can happen.
Peak integration, background subtraction, flow correction, absolute activity calculation etc can be performed manually or automatically. Limit-of-detection is determined for every ROI, displayed and printed. GINA Star program can control all modules of Agilent HPLC. All data and parameters are stored under one identity code. GINA Star can be installed as well in background of the original HPLC-operation program and the user can use the operation program of the HPLC supplier as well as the advantages of GINA Star.
ɣ radioactivity HPLC radiochemical purity test
20 – 2000 keV multiple nuclides
automatic energy calibration
2 simultaneous counting channels
free threshold settings
extremely high dynamic range 0 – 600.000 c/s
LCD 4 lines, 20 characters each
keybord: 16 touch sensitive keys
output: 0 – 1 V
digital communication to PC
including GINA Star program
live record on PC screen
no range overriding
peak integration, manual or automatic
limit-of-detection calculation
statistical accurcy for every integral
GABI Star radioactivity-HPLC-flow-monitor, 3x3" NaI scintillation detector
GABI Star 3" pin-hole
TECHNICAL DATA ORDERING INFORMATION
γ
GABI Star
energy range: 10 – 2000 keV high voltage range: 500 – 2000 V count rate: 0 – 600.000 c/s
data input: 7 analog input channels, -0.5 to + 4.5V resolution 21 bit
data output: RS 232 C, 2 analog outputs 0 - 1V resolution 20 bit
SCINTILLATION PROBES
NaI(Tl) size: 3x3"
pin hole size: 16 mm diameter 40 mm deep
energy range: 600 – 2000 keV
typical nuclide: 59Fe
shielding: 50 mm lead
01050100 GABI Star ɣ-HPLC-flow-detector
with keyboard and display
analog output 0 – 1V
digital output to PC
01052005 GABI Star scintillation probe 3x3" pin-hole, 16 x 40 mm
01052015 GABI Star 50 mm lead shielding
01059027 GABI Star flow cell 3x3” pin-hole
01058004 ɣɣ- reference source, 137Cs for 2x2", 3x3"
option
PC + Windows program
0124012 GINA 4-channel programm incl. manual evaluation
01058007 ɣ- reference standard
01240074 installation
01240074 installation GABI Star stand alone
01240239 training GABI Star stand alone
01240218 installation GABI Star with GINA Star
01240220 training GABI Star with GINA Star
ɣ-spectrum reference standard 137Cs in 3x3" pin-hole scintillation detector ɣ-spectrum of 18F in 3x3" pin-hole scintillation detector
0 500 1000 1500 keV
Tr1
0 500 1000 1500 keV
0
20
40
60
80
100
120
140
160
180 CPS/keV
Ba 32keV
Cs137 662keV
Integraton N:\walker\3x3 pinhole cs137 spectrum\3x3 pinhole cs137 spectrum, IQ OQ 3_7_09
Start: 03.07.2009 16:35
Sample descripton
Measurement:ऀ IQ OQ 3_7_09, started:ऀ 03.07.2009 16:35
Method:ऀ Mucha from:ऀ 03.07.2009 16:30
Zählrate ( 27.083) überschreitet die Gerätespezifkaton ( 20.000)
3x3" NaI pinhole Ser.Nr. 185 Crydet WT76S/UA78
Mucha Star #1276
Cs137 #37195 9,7 kBq
Measurement tme: 1 min
Integration N:\Helfer\Messungen\MUCHA 3 Bohrloch\F-18, 140605_01 Start: 05.06.2014
11:39
0 500 1000 1500 keV
SumTrace
0 500 1000 1500 keV
0
50
100
150
200
250
300CPS/keV
Vernichtungspeak
Summenpeak
Probenbeschreibung
Messung: 140605_01, gestartet: 05.06.2014 11:39
Methode: F-18 vom: 05.06.2014 11:37
Zählrate ( 81.820) exceeds the insturment specification ( 50.000)
Messung mit 3" Bohrlochsonde
Software Version: 5.9, Service Pack 9, Build 5079
Integration SumTrace
Substanz Ret Typ Fläche %Fläche
keV cps %
Vernichtungspea
k
508,00 BB(M) 18758,64 68,38
Summenpeak 1024,00 BB(M) 8675,73 31,62
Summe in ROI 27434,37 100,00
Fläche (total) 81663,66
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com54 |
ɣ- miniGITA Star ɣ- radioactivity-TLC-scanner, BGO scintillation crystal
ɣ radioactivity TLC
30 – 1600 KeV, BGO
radiochemical purity
single trace TLC
one plate 200 x 200 mm
multiple nuclide
one trace scan 25 x 200 mm
automatic energy calibration
extremely high counting rate
dead time correction
automatic decay correction
live display on screen
peak integration, TLC evaluation
limit-of detection calculation
miniGITA Star is a scanning device, which moves a radioactivi-ty detector along one trace from start to front.
The repeated, fast, continuous detection from start to front and back compensates automatically the radioactive decay of the compound over the scan length.
For ɣ- nuclides, miniGITA Star is using a scintillation probe with a BGO crystal. Due to its density, BGO has a quite high stopping power for gamma radiation and a reasonable energy resoluti-on. BGO is mechanically stable and non hydroscopic. Relative small size and special shape enable a sophisticated design of the scintillation probe.
There are 5 mechanical collimators designed for the energy ranges of 0 - 60 keV, 60 - 150 keV, 150 - 250 keV, 250 - 450 keV, > 450 keV. Depending on the radiation energy of the radioac-tive compound, the suitable collimator is inserted into the de-tector. Simple tools help to keep the distance exactly the same between the sample surface and detector entry window.
miniGITA Star offers a calibration and sensitivity self check.
Using a suitable reference standard and running the calibration program will result in an energy spectrum scan and calibration.
After a scan the TLC-plate can be moved manually to the fol-lowing trace and the next TLC can be examined.
The chromatogram is displayed live on the screen of the
connected PC. Peak integration and evaluation can be perfor-med manually or automatically.
The measurement and data handing is digital (single event counting) and limit of detection can be determined for every small peak.
TECHNICAL DATA ORDERING INFORMATION
γ
ɣ-miniGITA Star
Scan area: 25 x 200 mm
Scan speed: selectable
Traces: 1
Detector: BGO - scintillation probe
Nuclides: gamma
Energy: 50 – 1600 keV
Activity: 10 Bq – 100 MBq
Decay: corrected
Maximum countrate: 200.000 cps
COLLIMATORS
0-60 keV stainless steel, typical nuclide I-125 3 mm high
60 – 150 keV tungsten, typical nuclide 99mTc 5mm high
150 – 250 keV tungsten, typical nuclide In-111 10 mm high
250 – 450 keV tungsten typical nuclide I-131 15 mm high
> 450 keV tungsten typical nuclide 18F 20 mm high 123I bkg 0.7 cps (20 - 100 keV) sensitivity 20 Bq in 10 min. resolution 2 - 3 mm depending on collimator
02900012 minGITA Star -TLC-scanner all programs included
02900005 miniGITA Star collimator 60 - 150 keV
02900011 ɣ- reference source with holder
option
02900004 miniGITA Star collimator 0 - 60 keV
02900006 miniGITA Star collimator 150 - 250 keV
02900007 miniGITA Star collimator 250 - 450 keV
02900008 miniGITA Star collimator > 450 keV
01240206 installation
01240212 training
complete installation requires PC and WINDOWS
ɣ-spectrum 137Cs, 27kBq, energy calibration, BGO scintillationradioactive TLC, 99mTc
Integration N:\Geber\miniGita\Spektrum\13G1037_Cs.rsp Start: 19.11.2013 13:53
100 200 300 400 500 600 700 keV
TLC
100 200 300 400 500 600 700 keV
0
5
10
15
20
25
30
35
40
45
50
55
60
65C/keV
Reg #1
Probenbeschreibung
Messung: 13G1037_Cs.rsp, gestartet: 19.11.2013 13:53
Messzeit: 0:04:49 Auflösung: 6,27 keV
Hochspannung: 745,0 V
HV= 745 V
Radioaktivitätsdetektor: raytest MiniGITA Serien Nr..: 1301077
Andere Quadratisch-Durchflußzelle #0
Software Version: 5.9, Service Pack 9, Build 5079
Integration TLC
Substanz Ret Typ Fläche %Fläche
keV Counts %
Reg #1 665,10 DD(M) 6272,000 100,00
Summe in ROI 6272,000 100,00
Fläche (total) 13205,000
Ext. BKG. 0,00 C/keV
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com56 |
GITA Star ɣ- radioactivity-multi-TLC-scanner, BGO scintillation detector
ɣ radioactivity TLC
radiochemical purity
multiple trace TLC
2 plates 200 x 200 mm
multiple nuclides
80 trace scans on 2 TLC plates 200 x 200 mm
automatic energy calibration
extremely high counting rate
dead time correction
automatic decay correction
live display on screen
peak integration,
TLC evaluation
limit-of detection calculation
GITA Star is a scanning device, which moves the radioactivity detector along one trace from start to front and goes to the next pre-programmed trace position and scans that trace with individual nuclide settings.
For ɣɣ- nuclides, GITA Star is using a scintillation probe with a BGO crystal. Due to its density, BGO has a quite high stopping power for radiation and a resonable energy resolution. BGO is mechanically stable and non-hydroscopic. Relative small size and special shape enable a sophisticated design of the scintil-lation probe.
There are 5 mechanical collimators designed for the energy ranges of 0 - 60 keV, 60 - 150 keV, 150 - 250 keV, 250 - 450 keV, >450 keV. Depending on the radiation energy of the radioactive compound, the suitable collimator is inserted into the detector. Simple tools help to keep the distance exactly the same bet-ween the sample surface and detector entry window.
GITA Star offers a calibration and sensitivity check by a refe-rence source.
After all traces of one TLC plate 200 x 200 mm are ready, the second TLC-plate 200 x 200 mm can be measured.
A single chromatogram can be displayed live on the screen of the connected PC. Multiple traces can be displayed 3- dimen-sional.
Peak integration and evaluation can be performed manually or automatically. The measurement and data handling is digital (single event counting) and limit of detection can be deter-mined for every small peak.
scintillation probe 18F linearity on TLC
TECHNICAL DATA ORDERING INFORMATION
γ
GITA Star
Scan area: 400 x 200 mm
Scan speed: selectable
Traces: 80
Detector: BGO - scintillation probe
Nuclides: gamma
Energy: 30 – 1600 keV
Activity: 10 Bq – 100 MBq
Decay: corrected
Maximum countrate: 200.000 cps
COLLIMATORS
0-60 keV stainless steel, typical nuclide I-125 3 mm high
60 – 150 keV tungsten, typical nuclide Tc-99m 5mm high
150 – 250 keV tungsten, typical nuclide In-111 10 mm high
250 – 450 keV tungsten typical nuclide I-131 15 mm high
> 450 keV tungsten typical nuclide F-18 20 mm high 123I bkg 0.7 cps (20 - 100 keV) sensitivity 20 Bq in 10 min. resolution 2-3 mm depending on collimator
07000010 GITA Starɣmultiple-TLC-scanner all programs included
02900005 GITA Star collimator 60 - 150 keV
02900011 ɣy- reference source with holder
option
02900004 miniGITA Star collimator 0 - 60 keV
02900005 miniGITA Star collimator 60 - 150 keV
02900006 miniGITA Star collimator 150 - 250 keV
02900007 miniGITA Star collimator 250 - 450 keV
02900008 miniGITA Star collimator > 450 keV
01240242 installation
1240243 training
complete installation requires PC and WINDOWS
ɣ-spectrum 137Cs, 27 kBq, energy calibration „BGO scintillator“radioactive TLC, 123I
Integration N:\Geber\miniGita\Spektrum\13G1037_Cs.rsp Start: 19.11.2013 13:53
100 200 300 400 500 600 700 keV
TLC
100 200 300 400 500 600 700 keV
0
5
10
15
20
25
30
35
40
45
50
55
60
65C/keV
Reg #1
Probenbeschreibung
Messung: 13G1037_Cs.rsp, gestartet: 19.11.2013 13:53
Messzeit: 0:04:49 Auflösung: 6,27 keV
Hochspannung: 745,0 V
HV= 745 V
Radioaktivitätsdetektor: raytest MiniGITA Serien Nr..: 1301077
Andere Quadratisch-Durchflußzelle #0
Software Version: 5.9, Service Pack 9, Build 5079
Integration TLC
Substanz Ret Typ Fläche %Fläche
keV Counts %
Reg #1 665,10 DD(M) 6272,000 100,00
Summe in ROI 6272,000 100,00
Fläche (total) 13205,000
Ext. BKG. 0,00 C/keV
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com58 |
ɣ total activity meter
nuclear medicine
radiopharmaceutical QC
PET quality control
The well-type ionisation chamber is designed for all potenti-al applications in nuclear medicine and radiopharmaceutical production.
The sensitive electronics is integrated in the foot of the upright standing chamber.
The accuracy over a very large range of activity is very high. The long term stability is due to the sealing technology of the chamber excellent.
Tools for samples and various positioning are supplied.
The measurement geometry is almost 4 Pi.
Background is automatically measured and compensated.
Absolute activity is automatically calculated for more than 30 nuclides.
Minimization of components, integration of all components into the flat housing, requiring only little set up space.
State-of-the-art, powerful computer technology according to the industry standard.
Menu guided Windows based software.
Integration into network and combination with database sys-tem possible for radiopharmaceutical balancing and measure-ment.
Integrated quality control according to EN / DIN standard with protocol printout and data monitoring.
Software includes program for radiopharmaceutical identity checks, e.g. during production of PET nuclides.
User specific result display through adjustable user interface.
Container (syringe size, ampoule, bottle, capsule) and contents are taken into account.
(important especially withɣβ- sources)
Measurement of the activity of all nuclides common in PET; measuring range up to 300 GBq, rapid determination of the bottled activity (T= 1 – 1.5 s).
Background measurement and compensation.
Calculation of measured value for freely selectable application times.
Allocation of measured value to patient possible.
Network connection with patient database.
Reliable chute ionisation chamber in various design.
High measurement accuracy, low position dependency of sam-ple.
Connection of several measurement chambers to one central electronics (multi-chamber-concept).
Upgrade of measurement electronics with additional I/O ports e.g. to control syringe filling machines.
Combinable with:
- laser scanner for reading barcodes.
- transponder readers for control of access right - network systems
Expandable by user-specific software e.g.
- depot management
- nuclide management
- balancing
Certified in accordance with Medical Product Act CE 0123
ISOMEDdose calibrator
Dose calibrator ISOMED
BENEFITS
CONTINUED BENEFITS
TECHNICAL DATA ORDERING INFORMATION
γ
ISOMED
measuring range: 99mTc, 40 kB 9 – 50 GBq at 200 GBq 7% add. error 18F 60 kBq – 70 GBq at 300 GBq 7 % add. error
range setting: automatically alternative fixed for PET filling
energy range: 25 keV – 3 MeV gamma
measurement time:
incl. range change: 2 – 15 s
no rang change: 1-3 s
basic error: < 5 %
linearity error: < 2 %
result display: on screen
stored isotope table: 11C, 13N, 15O, 18F, 32P, 51Cr, 54Mn, 57Co, 58Co, 59Fe, 60Co, 67Ga, 75Se, 89Sr, 90Y, 99Mo, 99mTc, 111In, 113In, 123I, 125I, 131I, 133Xe, 137Cs, 140Ba, 153Sm, 169Er , 169Yb, 186Re, 188Re, 197Hg, 201Tl, 224Ra
containers:
injector syringe: 1, 2, 3, 5, 10, 20 ml
bottles: 5, 10, (P6) 15, 20 ml
ampoules: 5 ml
contents: 0.1- 99.9 ml
measurement cham.: 125/184 mm diameter chute diameter 47 mm
height: 387 mm, chute depth 205 mm
shielding: 4 mm basic Pb shielding
additional: 16 or 50 mm Pb shielding
Dose calibrator ISOMED
07161025 Activimeter 2010 dose calibrator PD version
07161022 Activimeter calibration source, 137Cs, 5 MBq
alternative:
07161023 shielding 16 mm wall
alternative:
07161024 shielding 50 mm wall
option:
01240074 installation dose calibrator
FEATURES
high energy range
more than 30 nuclides
very high accuracy
long term stability
PC-version
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com60 |
ɣ spectroscopy
nuclide impurity, low energy
food analysis, low energy
water analysis, low energy
waste analysis, low energy
easy operation
life spectrum display
selectable nuclide ROI`s
calibration to Bq
storage of measurements
management of files
MUCHA Nova The gamma radiation measuring system is designed for analysis of environmental samples or for determi-nation of very low activities in food, water waste samples, etc.
The use of the multi-channel-analyser is simple and self explai-ning. The user is guided through a dialog on the screen.
Display of the measured spectrum is live.
Automatic energy calibration is obtained by using a suitable
137Cs calibration source.
Selected energy regions are coloured.
Background spectra can be accumulated and automatically subtracted.
In order to offer a suitable spectrum display, a low, medium and high energy range can be selected.
MUCHA Novamulti-channel-analyser for ɣ- spectroscopy, 1x1" NaI(TL)
1024 channel MUCHA Nova, 1“ NaI(TI)
Integration H:\GD\S25S_UA50_Cs137_1 Start: 24.06.2014 12:36
0 500 1000 1500 keV
Tr1
0 500 1000 1500 keV
0
1
2
3
4
5
6
7
8
9
10 CPS/keV
32 keV
662 KeV,!37 Cs
Sample description
Messung: S25S_UA50_Cs137_1, started: 24.06.2014 12:36
Methode: Mucha from: 24.06.2014 12:39
3.3 MBq 137Cs (LR620). NaI 1" cristall distance to source 25cm.
Software Version: 5.9, service pack 9, Build 5079
Integration Tr1
Substanc
e
Net R/T Type Area %Area R/T Start Stop Half life
t.
keV cps % keV keV keV min
32 keV 32,00 BB(M) 77,9131 33,62 32,00 14,00 52,00 -
662
KeV,!37
Cs
738,00 BB(M) 153,846
0
66,38 738,00 646,00 812,00 -
Sum in
ROI
231,759
1
100,00
Area
(total)
1179,92
00
Ext.
BKG.
0,00
CPS/ke
V
ɣ-spectrum 1x1" NaI(Tl) full crystal, 137Cs standard
TECHNICAL DATA ORDERING INFORMATION
γ
MUCHA Nova
range: 1024 channels
conversion time: free running ADC
signal input: positive
offset: adjustable
lower discriminator: adjustable
high voltage: 0 – 1300 V
preamplifier: automatic
amplifier: automatic
display: on PC
power: 90 – 260 VAC, 50 – 60 Hz
temperature: 5 – 40°C
ɣ-spectrum, 18F, 1x1" NaI(TI) ɣ-spectrum 1x1", full crystal, 99mTc
12000302 MUCHA Nova 1024 channel analyser I/0 to PC incl. program
01052000 Scitillation Detector NaI(TI) 1” full crystal
01052015 leadshielding for 1" scintillation detector
01058007 ɣ- refernece standard 137Cs, 9 kBq, disk source
01240099 installation
01240211 training
Integration N:\Helfer\MUCHA 1-Zoll Vollkristall (Mainz)\F-18\140704_01 Start:
04.07.2014 10:40
0 100 200 300 400 500 600 700 keV
Tr1
0 100 200 300 400 500 600 700 keV
0
2
4
6
8
10
12
14
16
18
20
22
CPS/keV
18-F
Probenbeschreibung
Messung: 140704_01, gestartet: 04.07.2014 10:40
Methode: F-18 vom: 04.07.2014 10:41
1" Vollkristalldetektor
Software Version: 5.9, Service Pack 9, Build 5079
Integration Tr1
Substanz Ret Typ Fläche %Fläche
keV cps %
18-F 516,00 BB(M) 1169,077 100,00
Summe in ROI 1169,077 100,00
Fläche (total) 3767,275
Ext. BKG. 0,00 CPS/keV
Integration N:\Helfer\MUCHA 1-Zoll Vollkristall (Mainz)\Tc-99m\140704_01 Start:
04.07.2014 10:20
0 100 200 300 400 500 600 700 keV
Tr1
0 100 200 300 400 500 600 700 keV
0
50
100
150
200
250
CPS/keV
Reg #1
Probenbeschreibung
Messung: 140704_01, gestartet: 04.07.2014 10:20
Methode: Tc-99m vom: 04.07.2014 10:18
1" Vollkristalldetektor
Software Version: 5.9, Service Pack 9, Build 5079
Integration Tr1
Substanz Ret Typ Fläche %Fläche
keV cps %
Reg #1 146,00 BB(M) 5890,372 100,00
Summe in ROI 5890,372 100,00
Fläche (total) 8134,717
Ext. BKG. 0,00 CPS/keV
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com62 |
ɣ spectrometry
nuclide impurity
food analysis
water analysis
waste analysis
easy to use
life spectrum display
selectable nuclide ROI`s
calibration to Bq
quality control for PET
MUCHA Nova the gamma radiation measuring system is desi-gned for applications, for analysis of environmental samples or for determination of very low activities in food, water and waste samples.
The use of the multi-channel-analyser is simple and self explai-ning. The user is guided through a dialog on the screen.
Every screen offers all operational functions as needed for the analysis to be performed.
Display of the measured spectrum is live.
Automatic energy calibration is obtained by using a suitable 137Cs calibration source.
Selected energy regions are coloured.
Background spectra can be accumulated and automatically subtracted.
In order to offer a suitable spectrum display, a low, medium and high energy range can be selected.
MUCHA Novamulti-channel-analyser for ɣ- spectroscopy, 2x2" NaI(TI)
1024 channel MUCHA Star, 2" NaI(TI)
TECHNICAL DATA ORDERING INFORMATION
γ
MUCHA Nova
range: 1024 channels
conversion time: free running ADC
signal input: positive
offset: adjustable
lower discriminator: adjustable
high voltage: 0 – 1300 V
preamplifier: automatic
amplifier: automatic
display: on PC
power: 90 – 260 VAC, 50 – 60 Hz
temperature: 5 – 40°C
137Cs, 9 kBq energy calibrationMarinelli 1 l, 2x2" NaI(TI), mixed calibration source
01240238 MUCHA Nova 1024 channel analyser I/0 to PC incl. program
09400530 MUCHA Nova 2x2" NaI(TI)
09400534 MUCHA Nova lead shielding, 50 mm Copper 2 mm
01058007 ɣ- refernece standard 137Cs, 9 kBq, disk source
PC + Windows program
options:
01240099 installation
01240211 training
APPLICATION
GENERAL DESCRIPTION FEATURES
www.raytest.com64 |
ɣ spectrometry
nuclide determination
nuclide impurity
food analysis
water analysis
waste analysis
easy to use
life spectrum display
selectable nuclide ROI`s
calibration to Bq
nuclide impurity in %
quality control for PET
MUCHA Star the gamma radiation measuring system is desi-gned for applications, for analysis of environmental samples or for determination of very low activities in food, water and waste samples.
The use of the multi-channel-analyser is simple and self explai-ning. The user is guided through a dialog on the screen.
Every screen offers all operational functions as needed for the analysis to be performed.
Display of the measured spectrum is live.
Automatic energy calibration is obtained by using a suitable 137Cs calibration source.
Selected energy regions are coloured.
Background spectra can be accumulated and automatically subtracted for the selected measurement time.
In order to offer a suitable spectrum display, a low, medium and high energy range can be selected.
At the end of any measurement the spectrum can be printed or transferred for further analysis or storage to a PC.
MUCHA Nova multi-channel-analyser for ɣ- spectroscopy, 3x3" NaI(TI)
1024 channel UCHA Star, 3“ NaI(TI)
TECHNICAL DATA ORDERING INFORMATION
γ
MUCHA*
range: 1024 channels
conversion time: free running ADC
signal input: positive
offset: adjustable
lower discriminator: adjustable
high voltage: 0 – 1300 V
preamplifier: automatic
amplifier: automatic
display: on PC
power: 90 – 260 VAC, 50 – 60 Hz
temperature: 5 – 40°C
calibration 137Cs, 3x3" NaI (TI)multi element standard, 3x3" NaI (TI)
01240238 MUCHA Star multi channel analyser incl. PC program
09400515 MUCHA Star 3x3" NaI(TI) pin-hole, 16 x 40 mm
09400534 MUCHA Star lead shielding, 50 mm Copper, 2 mm
01058007 ɣ- refernece standard 137Cs, 9 kBq, disk source
094005 MUCHA Star Marinelli beaker 1 liter
PC + Windows program
options:
01240099 installation
01240211 training