2012 04 24 Runway Ice Warning System

15
Runway Ice warning systems

description

Sensors for runway freeze point detection independent of de icing material types.

Transcript of 2012 04 24 Runway Ice Warning System

Page 1: 2012 04 24 Runway Ice Warning System

RunwayIce warning systems

Page 2: 2012 04 24 Runway Ice Warning System

Benefit – Ice warning systems» permanent control of the runway for

24h a day and 7 days a week is possible.

» flight security can be optimized

» permanent acquisition of data will optimize the winter maintenance and in special the use of deicing fluids

» help to minimize control trips and organize them more effective

Page 3: 2012 04 24 Runway Ice Warning System

Benefit – Ice warning systems» Certified acquisition of data

» Automatic backup and verification of the runway status (data) » Use in case of refund

examination

» Use of the runway status for airlines possible

Page 4: 2012 04 24 Runway Ice Warning System

System structure

Page 5: 2012 04 24 Runway Ice Warning System

Passive & active RWY sensors

Page 6: 2012 04 24 Runway Ice Warning System

Passive Runway sensor

IRS31-UMB

» Measurement principle:Passive salt concentrations- and freeze point temperature measurement by measuring the conductivity dependent on water film height

Page 7: 2012 04 24 Runway Ice Warning System

Passive Runway sensor

IRS31-UMB

Measurement of…» RWY surface temperature» RWY depth temperature in 5cm and 30cm» Water film height up to 4mm» RWY condition (dry, damp, wet, critical

wetness, critical (snow/ice))

Page 8: 2012 04 24 Runway Ice Warning System

Passive Runway sensor

IMPORTANT:No measurement of freezing point temperature in runway applications with IRS31-UMB possible because of use of deicing fluid

Page 9: 2012 04 24 Runway Ice Warning System

Active runway sensor

ARS31-UMB

» Measurement principle:Measurement of salt concentration and freeze point temperature by active cooling and heating of the sensor surface.

Page 10: 2012 04 24 Runway Ice Warning System

Active runway sensor

Measurement of…» Freezing point temperature

(independent of used deicing fluid)» Deicing fluid concentration

Page 11: 2012 04 24 Runway Ice Warning System

System structure

Only with combination of passive and active RWY sensor determination of following parameters possible:

» RWY surface temperature» RWY depth temperature (5+30cm)» Water film height up to 4mm» RWY condition (dry, damp, wet, critical wetness,

critical (snow/ice))» Freezing point temperature» Deicing fluid concentration

Page 12: 2012 04 24 Runway Ice Warning System

All-in-one weather station

Page 13: 2012 04 24 Runway Ice Warning System

All-in-one weather station

WS600-UMB

Measurement of…» Air temperature» Rel. Humidity» Dew point» Air pressure» Wind speed and wind direction» Precipitation intensity» Precipitation type

Page 14: 2012 04 24 Runway Ice Warning System

References

» Airport Düsseldorf, Germany

» Airport Paderborn, Germany

» Airport Turin, Italy

» Military Airport Jever, Germany» Military Airport Spangdahlem,

Germany

Page 15: 2012 04 24 Runway Ice Warning System

G. Lufft Mess- und Regeltechnik GmbH

Gutenbergstr. 2070736 Fellbach

Web: www.lufft.com || E-Mail: [email protected]