2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

9
1 9 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate Function description: BMW 740Li replaced the fuel injectors of cylinder 1 and cylinder 2, and adjust the fuel injection rate after replacement. Steps1. replaced injector. 2. install injector 1;

Transcript of 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

Page 1: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 1 页 共 9 页

2011 BMW 740Li Replaces Injectors And Adjust Injection Rate Function description: BMW 740Li replaced the fuel injectors of cylinder 1 and cylinder 2, and adjust the fuel injection rate after replacement. Steps: 1. replaced injector.

2. install injector 1;

Page 2: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 2 页 共 9 页

3. install injector 2;

4. Click "ECM (Engine Control Module-DME/DDE)" enter the system;

Page 3: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 3 页 共 9 页

5. Select "Special Function".

6. Select "Injection rate adjustment";

Page 4: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 4 页 共 9 页

7. Click "[2] perform injector quantity compensation”;

8. Read the prompt information and click "OK";

Page 5: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 5 页 共 9 页

9. The currently cylinders value;

10. Click "[1]" to input the new calibration value of cylinder 1;

Page 6: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 6 页 共 9 页

11. Input the new value;

12. Click "[2]" to input the new calibration value of cylinder 2;

Page 7: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 7 页 共 9 页

13. Input the new value;

14. Click "[7]" to save the calibration value;

Page 8: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 8 页 共 9 页

15. Click "Yes" to save the Cylinder value;

16. The new value is permanently saved, click "OK";

Page 9: 2011 BMW 740Li Replaces Injectors And Adjust Injection Rate

第 9 页 共 9 页

17. Read the prompt information and click "OK";

18. When the test mode is over, click "OK";

The end.