    Optical Design of a Variable View Imaging System with

    Combination of a Telecentric Scanner and Double Wedge

    Prisms

    Xiaodong Tao1, Hyungsuck Cho,

    1,*and Farrokh Janabi-Sharifi

    2

    1Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology,

    373-1, Guseong-dong, Yuseong-dong, Daejeon, Korea

    2Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria Street,

    Toronto,Canada

    *Corresponding author: [email protected]

    Recent developments in the micro-electro-mechanical system (MEMS) and biotechnology

    have presented an emerging need for observation of dynamic targets in three-dimensional

    space. Unfortunately, the conventional microscopes with fixed optical parameters are

    difficult to supply sufficient vision information because of occlusion, small field-of-view

    (FOV) and low depth resolution. This paper introduces the design of a variable view

    imaging system which can supply a flexible view with a relative large zenith angle and a

    simple kinematics. Due to several performance factors, a multiobjective optimization

    process is applied to achieve an appropriate design. A prototype system is developed and

    used to verify the proposed design.

    OCIS codes: 110.1080, 220.1080, 120.4820, 150.3040, 170.0110, 170.0180, 220.4830.

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    2/21

    2

    1. Introduction

    The small field-of-view (FOV) and fixed view direction of conventional microscope cannot

    supply sufficient visual information needs for observation of dynamic targets in three-

    dimensional (3D) space, particularly in the fields of the micro-electro-mechanical systems

    (MEMS) and biotechnology applications. In the past, there have been several research efforts to

    solve this problem. Multiple fixed microscopes or moving stages are often applied in those

    applications [1,2]. Such approaches do not provide sufficient flexibility for observation of

    dynamic targets. A smart optical system with adjustable optical parameters becomes a promising

    solution. Potsaid has proposed an adaptive scanning optical microscope (ASOM) [3]. Through

    the integration of a scanning mirror and deformable mirror, the ASOM can obtain a large FOV

    with high resolution. A similar methodology is also applied in a scanning optical telescope [4].

    Another system capable of achieving foveated viewing in a large FOV has been demonstrated

    using a spatial light modulator (SLM)[5].

    In our previous research, a proposal was made for an active optical system which can change

    the view position and direction [6,7]. However, because of the coupling effect between the

    scanning mirror angle and view angle, the view angle is found to vary with scanning mirror,

    causing its zenith angle of view to decrease, making the kinematics complex. In order to solve

    those problems, a decoupled design of the system is proposed in this paper, which employs a

    telecentric lens. The basic concept of the system is presented in SPIE conference [8]. Since this

    design contains a number of parameters that affect the performance of te system, optimal

    election of these parameters is necessary. For this, an multiobjective optimization design process

    is described in this paper in detail for the first time. Experimental results are presented to show

    the validity of the proposed design.

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    3/21

    3

    2. Concept of the variable view imaging system

    The objective of the design of the variable view imaging system is to change the view state by

    control of active optical components in the system. The view state includes view position and

    view angles defined as Eq. 1.

    T

    w wV x y = (1)

    where (xw,yw) is the view position in a world coordinate. and are the azimuth angle and the

    zenith angle of the view.

    In the robot area, by installing a camera on a robot, an active vision system can change the view

    state easily. However, considering the size and weight of vision system and speed of scanning, it

    is difficult to install a microscope system on a robot. In order to realize this function, the idea is

    to design the vision system with active components which mimic the function of robot. Fig. 1

    shows the concept of the system. To steer the view angle (, ), double wedge prisms are applied

    because the compact size for deflection of light. The function of double wedge prisms is similar

    to a camera installed on a pan/tilt stage. It can steer the beam in any direction in a cone. To steer

    the view position (xw,yw), the telecentric scanner is applied. Its function is similar to a camera

    installed on the translation stage. Therefore by integration of these two active optical components,

    the proposed system can steer the both of view position (xw,yw) and orientation (, ). It can be

    considered as a camera installed on a robot with four degrees of freedom as shown in Fig. 1.

    In our previous research, a scanning mirror and double wedge prisms were used for view steering

    [6,7], where the scanning mirror angle was coupled with the zenith angle of the view. The zenith

    and azimuth angles changes with the change of the scanning mirror angle. There are several

    issues for the old design. The first issue is a small zenith angle. When the target locates near the

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    4/21

    4

    optical axis, the motion of scanning mirror decrease the zenith angle of view because the

    coupling effect between the scanning mirror angle and view orientation. The second issue is the

    complex kinematics relationship. Each variable in the view state is related to all variables in joint

    space as V=[fy(),fx(),f(),f()]T, where =[sx, sy, p1, p2]

    T is the vector of joint variables

    for scanning mirror and wedge prisms, respectively. fy(),fx(),f() and f() are the functions

    to calculate the four variables in the view state as shown in Eq. 1. The calculation of joint

    variables for a desired view state becomes difficult. And a precise alignment and calibration are

    required to obtain an accurate kinematics equations. To decouple the rotation angle of scanning

    mirror and view angles, a telecentric lens group is designed and introduced to the system. The

    system aperture is projected on the focal point of the telecentric lens. It makes the entrance pupil

    infinitely. Therefore in the object side, the chief rays are always parallel to the optical axis.

    The layout of the whole system is shown in Fig.2. The 3 rd and 4th lenses integrate a deformable

    mirror into the system. The deformable mirror is used for correction of aberration induced by

    wedge prisms. The 4th and 5th lenses relay the active aperture of the deformable mirror to the

    system aperture. The system aperture is projected onto the scanning mirror, which is located at

    the focal point of the telecentric lens. It makes an entrance pupil infinitely. Therefore the rays are

    always parallel to the optical axis in the object side. The azimuth angel and zenith angle of view

    are only related to the rotation angle of the prisms.

    In order to determine view state given the joint variables, a rigorous analysis of the view

    position and angle is made by the ray tracing method. The forward kinematics of the system can

    be defined as follows,

    1 2 1 2 1 2 1 2( , , , ) ( , , , ) ( , ) ( , )

    T

    x sx sy p p y sx sy p p p p p pV f f f f = (2)

    http://en.wikipedia.org/wiki/Entrance_pupilhttp://en.wikipedia.org/wiki/Entrance_pupil
  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    5/21

    5

    where V(xw,yw, , ) is the vector for view state. And (sx, sy, p1,p2 ) includes the joint variables

    for scanning mirror and wedge prisms. The detail derivation can be found in [7]. The inverse

    kinematics can be achieved by using a damped least-squares (DLS) method, which can also be

    refer to [7].

    3. Optimal design of the view steering part

    The view steering part include scanning mirror, telecentric lens and wedge prisms. The

    performances of the system, such as scanning area, maximum zenith angle, wavefront error are

    all related to this part. In this section, the system performance is defined. Because several system

    performance factors are involved, a muliobjective optimization process is applied to give an

    appropriate design.

    A. System performance for the system design

    System performance can be identified from the analysis of the functions of the system. The main

    function of the proposed system is to avoid the occlusion by changing the view angle. The

    effects of system parameters for the occlusion case can be shown in Fig. 3, where the image of a

    cubic with a depth D is captured by the proposed system. In the top view, the corner point B is

    occluded by the point A as shown in the figure. With a zenith angle , both point A and B can be

    observed in the image plane. Because of the telecentric lens group used in the system, the scaled

    orthographic projection model can be applied in the system. The distance between A and B in the

    image plane is defined as following equation.

    AB od Md=

    (3)

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    6/21

    6

    whereMis the magnification of the system. d0 is projected length of A and B along optical axis,

    which is defined as

    0 sin( )d D = (4)

    In order to avoid occlusion, the distance between A and B need to be observed in the image

    plane. Therefore the condition for the proposed system to avoid occlusion is as follows,

    sin( )o

    r D < (5)

    where ro is the optical resolution of the system. We can find that with high resolution r and larger

    zenith angle , the system can easily avoid occlusion. Therefore the maximum zenith angle and

    the resolution are two important performance factors for occlusion avoidance.

    Another function of the proposed system is to increase the field of view by steering the view

    position. In the whole scanning area, the area A2 with full azimuth angle with maximum zenith

    angle is most important as shown in Fig. 4. In this area, the system can achieve the view with an

    azimuth angle from 0 to 2 and a zenith angle from 0 to maximum zenith angle.

    As an optical system, image quality is also an important performance factors. Because the

    wedge prisms are used in the system, a relative large wavefront error is induced into the system.

    In this design, a deformable mirror is applied to correct this aberration. However the wavefront

    error correction is limited due to the limited stroke of the actuator in the deformable mirror. In

    the proposed system, a micromachined membrane deformable mirror (37ch, D15mm, OKO) is

    applied. The limitation of wavefront correction for this mirror is 3.5 (wavelength =0.660 m)

    according to [10]. Therefore in system design, the wavefront error should be kept inside this

    limitation. The details calculation of these system performances are described as follows.

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    7/21

    7

    Maximum zenith angle, max

    When two wedges have the same rotation angle, the zenith angle achieves its maximum value as

    shown in Fig. 5(a). Therefore for a given v, the maximum zenith angle is defined as

    max (0,0)v

    f = (6)

    Therefore max is a function of the vertex angle of the wedge prisms defined as follows,

    maxmax( )

    vF = (7)

    Fig. 5 (b) shows the final result of the relationship. Larger vertex angle of the wedge prisms can

    provide a larger zenith angle.

    Radius of view area, r2

    The configuration of the system for calculation of radius of A2 is shown in Fig. 6(a). The

    radius of the prism is defined as rp. The view will located at the boundary of the A2 when

    s px r= , 0sy = , 1 0p = ,

    2 0p = . Therefore the radius of A2 for a given v can be obtained

    from following equation,

    2( ,0,0 ,0 )

    vx pr f r

    = (8)

    r2is a function of the radius and vertex angle of wedge prism, defined as follows,

    2 2( , )

    r p vr F r

    =

    .(9)

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    8/21

    8

    This relationship is shown in Fig. 6(b). Comparing to the vertex angle v of prisms , the radius

    of the prism gives more effects on the change of r2.

    Optical Resolution

    The Optical resolution is the ability of a microscope to allow one to distinguish between small

    objects. The optical resolution ro is depend on the numerical aperture as shown in Eq. 9.[3]

    0.61o

    rNA

    =

    (10)

    where is the wavelength. NA is the numerical aperture, which characterizes the range of angles

    over which the system can accept. It can be defined as following equation.

    sin( / 2)NA n = (11)

    where n is the refraction index, is the angle of the maximum cone of light that can enter the

    objective lens.

    Peak-Valley Aberration, WPV

    The aberration of the system is variable depending on the wedge prisms angle and scanning

    mirror angle. It can be corrected by a deformable mirror which was applied in the system.

    However, because the correction limit of the deformable mirror, the peak-valley wavefront error

    should small than the correction range of the deformable mirror. For a specific design, the peak-

    valley wavefront is depending on the configuration of the prisms and mirror. The worst

    configuration with the maximum peak-valley wavefront error can be obtained from Zemax

    software as shown in Fig. 7(a), where xs=rp, ys=0, p1=0,p2=180. The maximum peak-valley

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    9/21

    9

    wavefront error is a function of vertex angle of prisms, radius of the prism and numerical

    aperture defined as follows,

    ( , , )PV pvW p v

    W F r NA= (12)

    It is difficult to achieve this relationship analytically. From Zemax software, the warefront

    errors for different rp, v and NA can be obtained easily as shown in Fig. 7(b). However, this

    discrete result is not accurate enough for the system design. Therefore a Backpropagation (BP)

    networks are built for function approximation [11]. In this design, a standard BP networks with 2

    hidden layers is applied. Each hidden layer has 10 neurons. The Tan-sigmoid transfer functions

    are applied in the networks. The data from the Zemax software was used for training data.

    B. Optimized Design of the system

    The objective of the optimized design is to achieve best performance of the system. In this

    design, there are four system performance factors for optimization. The object functions can be

    formulated as follows,

    2 max, ,,

    max ,max , max , minp vp v v

    o pvr NAr NA

    r r W

    (13)

    When the deformable mirror is applied the system, because the wavefront error inside a specific

    range can be corrected by the deformable mirror, the Wpv can be a boundary constraint in system

    design. Because the relationship between ro and NA defined in Eq. 9, ro can be replaced by NA

    to decrease the number of parameters for the design. Therefore the objectives of the system

    design can be simplified as following equation,

    2 max, ,

    max ,max ,maxp v p vr r

    r NA

    (14)

    Subject to ( , , )pv p vW r NA <

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    10/21

    10

    where is the correction limit of wavefront error for the deformable mirror. In this design, is

    set as 3.5 . As can be seen from Eq. 14, the optimal design becomes a multiobjective

    optimization problem. The performance factors are conflicted with each other. For example, The

    increase of vertex angle v of the prisms will increase the maximum zenith angle max, and also

    increase the wavefront error and decrease the radius of view area, r2. The increase of rp increases

    the radius of view area, r2, and also increases the wavefront error. Therefore, we can not get a

    single optimized solution from Eq. 14. In order to solve this Multi-Objective optimization

    problem, -constraint method is applied in this design according to [12]. This method is to select

    one of the objective functions to be optimized and all the other objective functions become

    constraint. This method can simplify the multiobject optimization problem to single objective

    optimization. In this design, the boundary of the numerical aperture NA, radius of view area r2

    can be defined based on the application. The objective of the design is to maximize the zenith

    angle max. Therefore the optimization problem can be simplified as

    max, ,

    maximizep vNA r

    (15)

    Subject to2 , ,r NA pvr K NA K W <

    Kr and KNA are the boundary of the r2 and NA, which can be determined based on the

    application by the designer.

    In order to solve the inequality-constrained optimization, a Logarithmic barrier method is

    applied [34]. The boundary of view area is determined by the application. In the microassembly

    application, the Kr is set as 5 mm. KNA is 0.03 in this design. The design result is shown in Table

    1. As can be seen, the maximum zenith angle,max

    is 22.29. In the real experiment, the in-stock

    components are selected with the most similar value achieved in the optimal design. The

    parameters for the real experiment setup are shown in Table 2. Based on the catalog of the wedge

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    11/21

    11

    prisms, the maximum vertex angle of the wedge prisms are 188, which gives a 19 degree of

    zenith angle. The zenith angle in the real experiment setup is only 3.3 less than the optimal

    design result.

    As discussed in the Section 3.1, the NA and max are two important factor for occlusion

    avoidance. By setting different KNA, the relationship between NA vs. max can be achieved from

    the optimal design solutions as shown in Fig. 8. As can be seen, when NA decrease to 0.02, 30

    degree of zenith angle max can be achieved. When the NA increases to 0.1, only 4 degree of

    zenith angle max can be achieved. This tradeoff relationship between NA and max is caused by

    the limitation of wavefront error correction for the deformable mirror. The NA and max in the

    current experiment system is shown in the Fig. 8, which is near the optical design set.

    4. Experiment results

    In order to investigate the feasibility of the proposed optical system design, A prototype system

    was constructed according to the Table 3. The 37-channel MMDM was supplied by OKO

    Technologies. The detailed information for wavefront correction can be referred to [10]. The

    deviation angle of one wedge prism was 10. The wedge prisms were installed on the compact

    rotation stages. Four achromatic lenses with effective focal length of 150 mm were used in the

    system.

    A. Experiment for the real object

    The ability of the proposed system to change the view without moving the object was

    demonstrated by multiple views of micro gears. Three views with different configurations are

    shown in Fig. 9(a) ~ (c). Fig. 9 (a) shows the view with a zenith angle =18.9 and an azimuth

    angle =90, where the hole in the 2nd gear can be observed. Fig. 9 (b) shows the view with a

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    12/21

    12

    zenith angle =18.9 and an azimuth angle =0. The depth of the 2nd gear can be observed. Fig. 9

    (c) shows the view with a zenith angle =18.9 and an azimuth angle =270, where the other

    side of the 2nd can be observed. In order to compare the imaging results with the previous system

    [7], the view state for the previous system is achieved in the proposed system. The max,2, for the

    previous system is determined from system kinematics, which equals to 13.8[7]. The three view

    states with zenith angle =13.8 is achieved as shown in Fig. 9(d)~(f). The interested features on

    the side of gears on the image plane are much smaller than the current system. The heights of

    gears, h1, h2, on the image plane for the previous system are 26 and 18 pixels respectively. In the

    proposed system, they are 36 and 25 pixels respectively, which is more than 35 percent larger

    than the coupled system. During online operation, the joint variables for a desired view state

    need be calculated in a short time. The numerical solution based on the damped least-squares

    (DLS) method is implemented, which is similar to the previous system [7]. Because of the

    simplified kinematics, only 23 iterations are need for calculation of joint variables, which is

    approximately 32ms in the current system. However, for the previous system, more than 350

    iterations are needed, which will spend 490ms.

    B. Experiment for the real application

    In the microassembly experiment, a microassembly system including three translational

    motions was installed near the proposed system. The preliminary experiment setup was only

    intended to evaluate the performance of the system; therefore, the microassembly system was

    teleoperated without automation. The task is to insert the micro electrode into the micro slot as

    shown in Fig. 10 (a). The widths of slot and electrode are 300um and 250um respectively. The

    electrode is held by a gripper. As shown in Fig. 10 (b). At an initial state, the view angle is set as

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    13/21

    13

    =0 and =0. The captured image is shown in Fig. 10 (b). The micro electrode will align with

    the slot in X direction as shown in Fig. 10 (c). However, the insertion part of the electrode cannot

    be observed because of occlusion. In order to align the electrode and slot in Y direction, the view

    angle is steered by the proposed system, and Fig. 10 (d) shows the image when a zenith angle

    is 19 and the azimuth angle is 0. With the visual information of the side surface, the electrode

    is aligned with the slot in Y direction as shown in Fig. 10 (e). The final assembly task is to insert

    the electrode into the slot. Fig. 10 (f) shows a final state of the assembly.

    5. Conclusion

    This paper presents the design of a variable view imaging system which can change the view

    angle and view position by actuating active optical components in the system. The proposed

    system with a telecentric lens group and double wedge prisms can supply a larger zenith angle of

    view and simpler kinematics relationship compare with the previous system [7]. During the

    system design, multi performance factors are identified. In order to obtain the best performance,

    a multiobjective design process is applied. The experimental results showed the validity of the

    proposed system to achieve a larger zenith angle at different azimuth angle. The focus of the

    future research will be on the automated operation of the system.

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    14/21

    14

    Reference

    1. M. Probst, K. Vollmers, B. E. Kratochvil and B. J. Nelson, Design of an advancedmicroassembly system for the automated assembly of bio-Microrobots, presented at 5th

    International Workshop on Microfactories, Besancon, France, 2527 October 2006.

    2. X. Hui, R. Weibin and S. Lining, A flexible experimental system for complexmicroassembly under microscale Force and vision-based Control, Int. J. Optomechatronics

    1, 81102, 2007.

    3. B. Potsaid, Y. Bellouard and J. Wen, Adaptive Scanning Optical Microscope (ASOM): amultidisciplinary optical microscope design for large field of view and high resolution

    imaging, Opt. Express 13, 65046518, 2005.

    4. C. Scott, B. Potsaid and J. Wen, Off-Axis aberration correction for a wide field scanningtelescope, in Proc. SPIE 7266, 72660Y, 2008

    5. H. Hua and S. Liu, A dual-sensor foveated imaging system, Applied Optics 47, 317-27,2008

    6. X. Tao, D. H. Hong, H. S. Cho, The design of active vision system for variable viewimaging of micro objects, in Proc. SPIE 6376, 637608112, 2006.

    7. X. Tao, H. S. Cho and F. Janabi-Sharifi, Active optical system for variable view imaging ofmicro objects with emphasis on kinematic analysis, Appl. Opt. 47, 4121-4132, 2008

    8. X. Tao, D. H. Hong, H. S. Cho, Variable view imaging system with decoupling design,International Symposium on Optomechatronic Technologies, Proc. of SPIE, 7266, 72661U-1

    - 11, 2008.

    9. J. R. Meyer-Arendt, Introduction to Classical and Modern Optics, Prentice Hall, 1995.

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    15/21

    15

    10.L. Zhu, P. C. Sun, D. U. Bartsch, W. R. Freeman and Y. Fainman, Wave-front generation ofZernike polynomial modes with a micromachined membrane deformable mirror, Appl. Opt.

    38, 60196026, 1999.

    11.S. Kumar, Neural Networks: A Classroom Approach, McGraw-Hill, 200512.K. Miettinen, Nonlinear Multiobjective Optimization, Kluwer Academic Publishers, 199913.H. S. Cho, Optomechatronic: Fusion of Optical and Mechatronic Engineering, CRC Press,

    2005.

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    16/21

    16

    Fig. 1. Concept of the variable view imaging system

    Fig. 2. The layout of the proposed system.

    Fig. 3. Avoid occlusion in the proposed system

    Fig. 4. View area A2 with full azimuth angle with maximum zenith angle

    Fig. 5. (a) The configuration of the wedge prisms with maximum zenith angle (b) The

    relationship between the vertex angle v (degree) of the wedge prism and max (degree)

    Fig. 6. (a) The configuration of the system for calculation ofr2(b)The relationship between

    2

    , ,p vr r

    Fig. 7. (a) The worst configuration with the maximum peak-valley (b) The warefront errors for

    different rp, v and NA

    Fig. 8. NA vs. max in the optimized design

    Fig.9. Multiple views of micro gears: (a)~(c) captured images in three different azimuth angle

    with =18.9 and (d)~(f) =13.8

    Fig. 10. Microassembly of a micro electrode and a slot, (a) microassembly task, and (b)~(f)

    captured images during the assembly.

    Table 1 The optimal design result

    Table 2 Specification of the experiment setup

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    17/21

    17

    Pan/tilt

    stageCamera

    Scanning

    lens

    Scanning

    mirror

    Translation stage

    Wedge

    prisms

    Fig. 1. Concept of the variable view imaging system

    camera

    telecentric

    lens

    scanning

    mirror

    wedge

    prisms

    deformable

    mirror 2nd lens

    3rd lens

    4th lens

    5th lens

    6th lens

    system

    aperture

    Xw

    Zw

    Ow

    Yw

    Zv

    Xv

    YvOv

    (xw,yw)

    view direction

    Object plane

    Fig. 2. The layout of the proposed system.

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    18/21

    18

    A

    A

    Telecentric lens

    groupA

    B

    B

    Image plane

    Occlusion

    Without occlusion

    do

    D

    di

    Fig. 3. Avoid occlusion in the proposed system

    Zv

    Xv

    Yv

    Ov

    max,2

    =0~2

    Fig. 4. View area A2 with full azimuth angle with maximum zenith angle

    v

    max

    0 10 20 30 40 50 600

    10

    20

    30

    40

    50

    60

    70

    80

    90

    max

    v

    (a) (b)

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    19/21

    19

    Fig. 5. (a) The configuration of the wedge prisms with maximum zenith angle (b) The

    relationship between the vertex angle v (degree) of the wedge prism and max (degree)

    pri sms

    rp

    2r2A 5

    10

    15

    20

    25

    0

    10

    20

    30

    -10

    0

    10

    20

    30r2(mm)

    Fig. 6. (a) The configuration of the system for calculation ofr2(b)The relationship between

    2, ,

    p vr r

    1st wedge prism

    2nd wedge prism

    Object plane0.1

    0.20.3

    0.40.5

    510

    1520

    250

    10

    20

    30

    40

    50

    60

    70

    80

    90

    rp v

    Wpv

    () NA=0.1

    NA=0.09

    NA=0.01

    (degree)(mm)

    (a) (b)

    Fig. 7. (a) The worst configuration with the maximum peak-valley (b) The warefront errors for

    different rp, v and NA

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    20/21

    20

    0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.15

    10

    15

    20

    25

    30max

    NA

    Curr ent exper i ment

    syst em

    Fig. 8. NA vs. max in the optimized design

    h1

    h2

    500m 500m 500m

    2nd gear

    1st gear

    h2

    (a) =18.9, =90

    (b)=18.9

    , =0

    (c)=18.9

    , =270

    h1

    h2

    500m 500m 500m

    h2

    (d) =13.8, =90 (e)=13.8, =0 (f)=13.8, =270

    Fig.9. Multiple views of micro gears: (a)~(c) captured images in three different azimuth angle

    with =18.9 and (d)~(f) =13.8

  • 7/28/2019 2010_AO_3D Scan_telecentric Scanner and Double Wedges

    21/21

    500um

    Gripper

    Electrode

    Slot

    500um

    (a) (b) (c)

    500um 500um 500um

    (d) (e) (f)

    Fig. 10. Microassembly of a micro electrode and a slot, (a) microassembly task, and (b)~(f)

    captured images during the assembly.

    Table 1 The optimal design result

    MaximumZenith angle,max

    22.29

    Scanner area, r2 5.56mmNA 0.0302Wavefront error,WPV 3.498, =685nmVertex angle, v 24.3Radius of prisms, rp 15.15 mm

    Table 2 Specification of the experiment setup

    Maximum Zenith angle, max 19

    Scanner area, r2 4.35 mm

    NA 0.033Wavefront error,WPV 2.4, =685nm

    Vertex angle, v 18.13

    Radius of prisms, rp 12.5 mm