20100105 TT Platform Rig Evaluation Matrix - FINAL

10
TECHNICAL COMMITTEE RIG NAME/NUMBER ASSUMPTIONS Technical specification required were defined to level 3 INSTRUCTIONS: 1. On rig evaluation sheet filling out the yellow cells. 2. Assign to each cell a number from 0.00 to 5.00, according to the response predetermined that closely match with the 3. The winner should be the Company with the higher score, summarized on the Results sheet, and on the Graphic Triangle 4. Those Companies score less than 37.7 point will be unable to evaluate from commercial point of view

description

20100105 TT Platform Rig Evaluation Matrix - FINAL

Transcript of 20100105 TT Platform Rig Evaluation Matrix - FINAL

TECHNICAL COMMITTEE

RIG NAME/NUMBER

ASSUMPTIONSTechnical specification required were defined to level 3

INSTRUCTIONS:

1. On rig evaluation sheet filling out the yellow cells.

2. Assign to each cell a number from 0.00 to 5.00, according to the response predetermined that closely match with the proposal

3. The winner should be the Company with the higher score, summarized on the Results sheet, and on the Graphic Triangle

4. Those Companies score less than 37.7 point will be unable to evaluate from commercial point of view

EVALUATION MATRIX - PLATFORM RIG TENDER

PROJETC TSP 2010-2011 Drilling Campaign GROUP OF EVALUATION HSE, Drilling & Completion, Facility & Construction.

REGION Caribbean

RATING COMPANIES RATING COMPANIES SCORE (Impact x rating) COMMENTS

Question Objective Impact 0 1 2 3 4 5 Baseline ScoreBaseline

AcceptanceH&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

Baseline Score

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

RATING COMPANIES RATING COMPANIES SCORE (Impact x rating) COMMENTS

Question Objective Impact 0 1 2 3 4 5 Baseline Score

IV TECHNICAL PROPOSAL - DRILLING & COMPLETIONS1 Type of Drilling Unit

a Platform Modular Drilling & Workover Rig? 5 No Yes 3 3 3 3 3 15 15 15 15 15 Yes Yes Yes

b API Certified (Spec 4F) 5 No Yes 3 3 3 2 3 15 15 15 10 15 API 4F-0027 Yes

1 Draw works

a How much power does the Rig have? 4 1500 Hp 2000 HP 3 5 5 3 3 12 20 20 12 12 2,500hp 3,000hp 2,000hp 2,000hp

2 Mastil (Lifting System)

a 5 1000000 Lbs 3 3 4 2 3 15 15 20 10 15 1,000,000lbs 1,200,000lbs 850,000lbs 1,000,000lbs

b 5 1000000 Lbs 3 3 4 2 3 15 15 20 10 15 1,120,000lbs 650Tons 650Tons 650Tons

c 5 <30,000ft-lbs 30,000ft-lbs >30,000ft-lbs 3 3 4 5 5 15 15 20 25 25 42,700ft'lbs continous

d 5 1000000 Lbs 3 3 4 2 3 15 15 20 10 15 650Tons 992000lbs 1,000,000lbs

3 Rotary System

a Does the Rig have a Top Drive Installed? 5 No Yes 3 3 3 3 3 15 15 15 15 15 Varco TDS-4S 3

b 2 < 37 1/2" 37 1/2" > 37 1/2" 3 3 3 3 3 6 6 6 6 6 37.5 37 1/2" 37 1/2" 37 1/2"

c 3 13,000 15000ft 3 3 5 2 3 9 9 15 6 9 1200000lbs 16,368' of 5" DP.

d 3 <30,000ft-lbs 30,000ft-lbs >30,000ft-lbs 3 4 5 1 5 9 12 15 3 15 32,500ft-lbs

4 Drilling Tubulars

a 5" DP tubulars included in contract? 3 No <8,000ft 10000ft 13,000ft x 5" DP 13,000ft x 5-7/8" DP 3 3 5 2 2 9 9 15 6 6

b 3-1/2 DP tubulars included in contract? 3 No <10,000ft 15,000ft 15,000fr + >20%XS 3 1 3 3 3 9 3 9 9 9 5,000ft available

c 5" HWDP tubulars included in contract? 2 No <300ft 450ft x 5" HWDP 3 3 5 4 4 6 6 10 8 8 15Jts x 5-1/2" HWDP 15Jts x 5-1/2" HWDP

d 3-1/2" HWDP tubulars included in contract? 2 No <300ft 450ft 450ft + >20% XS 3 5 5 3 3 6 10 10 6 6 15Jts x 3-1/2" HWDP 15Jts x 3-1/2" HWDP

e 8-1/4" DCs tubulars included in contract? 2 No <300ft 450ft 450ft + >20% XS 3 5 3 3 3 6 10 6 6 6 15Jts x 8" DC 15Jts x 8" DC

f 6-3/4" DCs tubulars included in contract? 2 No <200ft 600ft >900ft 3 5 3 1 1 6 10 6 2 2 None available None available

g 4-3/4" DCs tubulars included in contract? 2 No <200ft 450ft 600ft >900ft 3 4 2 2 2 6 8 4 4 4 24Jts x 4-3/4" DC 15Jts x 4-3/4" DC 15Jts x 4-3/4" DC

h 3 No 3 3 3 3 3 9 9 9 9 9

i 3 No 3 3 2 3 3 9 9 6 9 9

5

a 3 None > 7" 3 5 5 5 5 9 15 15 15 15 2-3/8" - 8-1/2" 2-3/8" - 8-1/2"

b 3 None <3-1/2" > 7" 3 5 5 5 5 9 15 15 15 15 Up to 9" Up to 8" 2-7/8" - 11-1/4" 2-7/8" - 10-3/4"

c 1 None Yes 3 3 3 3 3 3 3 3 3 3 Yes Yes Yes

d 2 None 1 2 >2 3 3 1 3 3 6 6 2 6 6

e 2 None 1 2 >2 3 3 1 3 3 6 6 2 6 6 2 x tugger winch 2 x tugger winch

f 2 None Yes 3 3 3 3 3 6 6 6 6 6 For 3.5" - 5" DP 3-1/2" - 5" DP 2-7/8" - 5-1/2" DP 2-7/8" - 5-1/2" DP

6 Mud Pumps & Circulating System

Baseline Acceptance

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

Baseline Score

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

To evaluate the suitability of the rig design application

Yes - Rig 5. Built in 1990

To determine if Rig Specs are in accordance to int'l standards

Seeking Certification

Expired Certification

Certified to work in T&T - currently

drilling for BGTT

Certified to work in GOM. Currently

stacked in Louisiana.

To evaluate the power at the Drawwork of the Rig

Lower than 1000 Hp

Between 1000-1200 Hp

>2000 HP in a range of 10-20%

>2000 HP in un range over 20%

What is the static working tensile capacity with 12 lines?

To evaluate the capacity of the mastil

lower than 800000 Lbs

>1000000 Lbs in a range of 10-

20%

>1000000 lbs in a range over 20%

What is the rotary working tensile capacity? (Up to Maximum Capacity of Mast)

To evaluate the capacity of the Top Drive

lower than 800000 Lbs

>1000000 Lbs in a range of 10-

20%

>1000000 lbs in a range over 20%

What is the Top Drive torque rating (120 - 160rpm)

To evaluate the capacity of the Top Drive

Continuous: 32,500Intermitent: 50,900

Low Gear: 45,500

High Gear: 29,100

42,700ft'lbs continous

What is the crown block rating? (Up to Maximum Capacity of Mast)

To evaluate the capacity of crown block

lower than 800000 Lbs

>1000000 Lbs in a range of 10-

20%

>1000000 lbs in a range over 20%

1,000,000lbs (w/12 lines)

To evaluate the capacity in the rotary system

Yes + back-up available in country

CanRig Model 1250 AC TDS

CanRig Model 1165E -650Tons

What is the Maximum O.D opening of the Rotary Table

To evaluate the capacity and characteristics in the rotary system

How much stand back capacity with 5" Drill Pipe does the Rig have?

Permit identify the maximum length of the well which will be drilled

Lower than 13,000ft

20,000ft of rated capacity

>20,000ft in a range of 10-20%

>20,000ft in a range over 20%

20000 (5¨DP) + 6stds x DCs

19,440' of 5" DP. (650,000lbs)

What is the Rotary Table torque rating (120-160rpm)

To evaluate the capacity of the Rotary Table

43,200 ft-lbs Continuous @

120RPM

42,700 ft-lbs Continuous 48,000 ft-lbs Intermittent

42,700 ft-lbs Continuous 48,000 ft-lbs Intermittent

To determine the tubular requirements for well design.

13,000ft x 5-1/2" DP

20,000ft x 5"DP available

13,000ft x 5-7/8" DP available

10,000ft x 5-1/2" 24.7# S-135 DP

10,000ft x 5-1/2" 24.7# S-135 DP

To determine the tubular requirements for well design.

15,000ft + 10-20% XS

15,000ft available

15,000ft x 3-1/2 13.3# S-135 DP

15,000ft x 3-1/2 13.3# S-135 DP

To determine the tubular requirements for well design.

450ft x 5-1/2" HWDP

450ft x 5-7/8" HWDP

30jts x 5" HWDP available

20jts x 5-7/8" HWDP available

To determine the tubular requirements for well design.

450ft + 10-20%XS

30jts x 3-1/2" HWDP available

20jts x 3-1/2" HWDP available

To determine the tubular requirements for well design.

450ft + 10-20%XS

24Jts x 8" DC available

15Jts x 8" DC available

To determine the tubular requirements for well design.

33 Jts x 6-1/2" DC available

24 Jts x 6-1/2" DC available

To determine the tubular requirements for well design.

15Jts x 4-3/4" DC (450ft)

Full compliment of DP Pup Jts, Well control Subs (Bit, Float, Pump In) and Crossovers for various tubular NC 50, NC38, Regular connections

To determine the tubular requirements for well design.

Yes1 ea.

Yes2 ea.

Yes 2 ea. + redundancy

2 ea in bit, float subs, crossovers

and pup jts.

2 ea in bit, float subs, crossovers

and pup jts.

2 ea in bit, float subs, crossovers and pup

jts.

2 ea in bit, float subs, crossovers and pup jts.

Does the rig have fishing equipment for their supplied tubulars. (9-1/2" DC, 8-1/4" DC, 5" DP)

To evaluate the level of support available in the event unplanned operations occur.

Yes(5" - 9-1/2")

Yes.Full compliment

5" - 9-1/2" + 7" - 13-5/8" Csg

Fishing equip. for contractor supplied tubulars (i.e5" - 3.5"

DP and 8" - 6.5" DCs)

Fishing Equip. to cover 3-1/2" - 6-3/4" Tubulars.

No DCs.

Fishing Equip. to cover 2-7/8" - 9-5/8"

Tubulars.

Fishing Equip. to cover 2-7/8" - 9-5/8"

Tubulars.

Rig Floor Peripherals and Accessories

Iron Roughneck & Pipe Spinner - Capable of making up and torquing all drillpipe sizes and connections to be provided by Contractor. Maximum versatility in vertical and horizontal movement should be considered?

To evaluate the ease and contribution to a safer operation.

Yes2-7/8" - 7"

Both roughneck (4" - 9.5") and pipe

spinner (2-7/8" - 5") available

Iron roughneck available (4” – 8

“)

Mouse Hole - What is the Mouse Hole Capacity?

To evaluate the ease and contribution to a safer operation.

Yes2-7/8" - 7"

Mouse Hole - Is the Mouse Hole capable of rotating?

To evaluate the ease and contribution to a safer operation.

Can be altered to facilitate rotation.

Note in tender states that

rotating mousehole will

be provided

Winches - How many utility winches to facilitate man ridding operations?

To evaluate the ease and contribution to a safer operation.

Assume 1 x manriding

1 x man riding 2 x man riding 2 x man riding

Winches - How many winches to facilitate equipment (tugger) operations?

To evaluate the ease and contribution to a safer operation.

2) on Drill Floor and (1) on Pump Deck

1 x monkey board

1 x tugger

Mud Bucket - Does the rig supply a mud bucket for wet pipe (3-1/2" - 5" DP) applications?

To evaluate the ease and contribution to a safer operation.

EVALUATION MATRIX - PLATFORM RIG TENDER

PROJETC TSP 2010-2011 Drilling Campaign GROUP OF EVALUATION HSE, Drilling & Completion, Facility & Construction.

REGION Caribbean

RATING COMPANIES RATING COMPANIES SCORE (Impact x rating) COMMENTS

Question Objective Impact 0 1 2 3 4 5 Baseline ScoreBaseline

AcceptanceH&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

Baseline Score

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

a How many pumps are installed in the Rig? 4 < 2 2 3 >3 3 4 4 3 3 12 16 16 12 12 3 X 1000 hp 2 x 1600HP 2 x 2000HP

b What is the rated input power (per pump)? 2 < 1000 HP 1300 HP 1600 HP > 1600 HP 3 3 1 3 5 6 6 2 6 10 3 x 1600hp 3 X 1000 hp 2 x 1600HP 2 x 2000HP

c 3 < 3000 Psi 4000 Psi > 4500 psi 3 5 5 5 5 9 15 15 15 15 5000psi 5000psi 5000psi 5000psi

d What kind of Stand Pipe Manifold is installed? 2 Single Double 3 5 5 5 5 6 10 10 10 10 Double Double Double

e 3 < 3000 Psi 4000 Psi > 4500 psi 3 5 5 5 5 9 15 15 15 15 5000psi 5000psi 5,000psi 5,000psi

f What is the maximum mud capacity? 4 < 1000bbls 1000 - 1500bbls 1500 - 2000bbls 2,200bbls >2,500bbls 3 2 1 1 1 12 8 4 4 4

g Does the Rig have a Trip Tank installed? 2 No < 30bbls 40bbls Yes 50bbls 3 3 5 4 5 6 6 10 8 10 30bbls capacity. 1ea x 50bbls 40bbl tank 2 x 25bbl tank

h Does the Rig have an LCM Pill Tank installed? 2 No Yes 50bbls Yes 100bbls Yes 200bbls 3 1 1 2 3 6 2 2 4 6 50bbls 50bbls 100bbls 150bbls

i How many Hoppers has the rig installed? 2 0 1 2 >2 3 3 3 3 3 6 6 6 6 6 2 mixing hoppers 2 mixing hoppers 2 mixing hoppers 2 mixing hoppers

j How many Mixing / Transfer Pumps? 3 0 1 2 3 >3 3 3 3 5 5 9 9 9 15 15

7 Bulk Storage Capacities

a Bulk Cement Storage Capacity? 3 No <3000cu.ft 3000cu.ft 4000cu.ft >4000cu.ft 3 1 2 1 1 9 3 6 3 3 (2 x 1200cuft) (3 x 1000cu.ft) 2 x 1000cuft 2 x 1000cuft

b Bulk Barite Storgae Capacity? 3 No <3000cu.ft 3000cu.ft 4000cu.ft >4000cu.ft 3 1 2 1 1 9 3 6 3 3 (2 x 1200cuft) (2 x 1000cu.ft) 2 x 1000cuft 2 x 1000cuft

c Bulk Bentonite (Gel) Storage Capacity? 1 No 1000cu.ft 3000cu.ft >3000cu.ft 3 0 1 1 1 3 0 1 1 1 None mentioned (1 x 1000cu.ft) 1 x 1000cuft 1 x 1000cuft

d Sand Traps Storage Capacity? 2 No <30bbls 30bbls >30bbls 3 0 1 3 3 6 0 2 6 6 None mentioned 30bbls 33bbls

e Potable Water Storage Capacity? 2 No <500bbls 1000bbls >1000bbls 3 3 1 3 3 6 6 2 6 6 375bbls

f Drill Water Storage Capacity? 2 No <500bbls 1000bbls >1000bbls 3 3 1 3 3 6 6 2 6 6 450bbls

g Diesel / Fuel Storage Capacity? 3 No <200bbls 200bbls >200bbls 3 5 5 3 3 9 15 15 9 9 460bbls 460bbls

h Oils & Lubes Storage Capacity? 2 No Yes 3 3 3 3 3 6 6 6 6 6 Volume not specified Volume not specified

i 2 No 3 3 3 3 3 6 6 6 6 6 120psi rated 120psi rated

j Water Maker System? 2 No <200bbls/day 500bbls/day >500bbls/day 3 2 3 2 2 6 4 6 4 4 580bbls / day 270bbls/day 270bbls/day

k 2 No Yes 3 3 3 3 3 6 6 6 6 6

8 Control Solids Equipment

a How many Shale Shakers has the rig installed? To evaluate the capacity of SCE 0 0 1 2 3 3 + Dryer 0 3 3 0 0 0 0 0 0 0 4 xShale Shakers

b To evaluate the capacity of SCE 0 No Yes 0 3 3 0 0 0 0 0 0 0

c To evaluate the capacity of SCE 0 No Yes 0 3 3 0 0 0 0 0 0 0 1 x Desander 1 x Desander

d Does the Rig have a Cuttings Dryer (MRU)? To evaluate the capacity of SCE 0 No Yes >1 0 0 0 0 0 0 0 0 0 0

e To evaluate the capacity of SCE 0 No Yes 0 0 0 0 0 0 0 0 0 0

f Is the Rig equipped with a Mud-Gas Separator ? 2 No 3 3 3 3 3 6 6 6 6 6 1000gpm 1000gpm

9 Well Control Equipment

a What kind of 13 5/8" BOP'S Stack is supplied? 5 < 5 K psi Single + Annular Double+Annular 3 5 3 3 3 15 25 15 15 15

b 1 No Yes 3 3 3 3 3 3 3 3 3 3 50T Dreco Hoist 2 x 25Ton Hoists BOP trolley Yes

c 2 doesn't have 1 2 3 5 5 5 5 6 10 10 10 10

d 5 < 3000 Psi 4000 Psi > 4500 psi 3 5 5 5 5 15 10ksi C&K Manifold 5000psi 5000psi

e 2 12 24 3 5 4 5 3 6 10 8 10 6 28 bottles

f 1 No Yes 3 3 3 3 3 3 3 3 3 3 MD-Totco MD-Totco MD-Totco MD-Totco

To evaluate the capacity of the circulating System

3 x GARDNER DENVER PZ-11

To evaluate the capacity of the circulating System

Between 1000-1200 HP

What is the Working Pressure of the Pumps System?

To evaluate the capacity of the circulating System

Between 3000-3500 Psi

Between 3500-3900 Psi

Between 4000-4500 Psi

To evaluate the capacity of the circulating System

2 Standpipes: 5 x 3-1/2 ID. With Kill, fill-up and

bleef-off outlets.

What is the Working Pressure of the Standpipe Manifold?

To evaluate the capacity of the circulating System

Between 3000-3500 Psi

Between 3500-3900 Psi

Between 4000-4500 Psi

To evaluate the capacity of the circulating System

300bbls over max expected hole

volume .

1475bbls (Active+Res)

1080bbls (Active+Res)

1317bbls (Active+Res)

1320bbls (Active+Res)

To evaluate the capacity of the circulating System

Yes30bbls

To evaluate the capacity of the circulating System

Yes150bbls

Yes, The rig has two Pill Tanks >200bbls

To evaluate the capacity of the circulating System

To evaluate the capacity of the circulating System

(3) ea 8 x 6 x 14 mixing centrifugal

pumps

2 x Mixing Pumps + 1 x

Transfer Pump

3 x mixing + 3 x transfer pumps

3 x mixing + 2 x transfer pumps

To evaluate the Rig's inventory capacity for required bulks

To evaluate the Rig's inventory capacity for required bulks

To evaluate the Rig's inventory capacity for required bulks

To evaluate the Rig's inventory capacity for required bulks

25bbls usable volume

To evaluate the Rig's inventory capacity for required bulks

Limited by Platform Space

2 x 500bbl tank under the

accommodation assembly.

2 x 500bbl tank under the accommodation

assembly.

To evaluate the Rig's inventory capacity for required bulks

Limited by Platform Space

Not requested in tender, however

contractor can supply at additional cost.

One pot water tank can also be used for

drill water

Not requested in tender, however

contractor can supply at additional cost.

One pot water tank can also be used for

drill waterTo evaluate the Rig's inventory capacity for required bulks

200bbl tank complete with 3" x 2" 5HP transfer pump

250bbl tank complete with 3" x 2" 5HP transfer pump

To evaluate the Rig's inventory capacity for required bulks

Limited by Platform Space

Volume not specified

Rig Air Compressor System (120 psi) with Air Dryer compatible with bulk handling & transfer system?

To evaluate capacity of Rig to support 3rd party equipment and services.

Yes120psi System

Two (2) Quincy QSI-370 rotary air compressors

Two (2) Quincy QSI-370 rotary air compressors

To evaluate the rig's capacity for sustainability.

Included in ISS accomodation

package

Sewerage System Capacity in excess of 100 people and must be able to monitor the sewage TSS, pH and Cl content.

To evaluate the rig's capacity for sustainability.

Omni-pure 12c System Omnipure 12 MX

Two (2) x 60 Men Omnipure

Two (2) x 60 Men Omnipure

3 + Dryer Shaker + 2 x Scalper

4 xShale Shakers

None - Not requested in RFQ

None - Not requested in RFQ

Does the Rig have a Desilter installed and in operative conditions?

1 x Centrifuge + 1 x Desilter

1 x Centrifuge + 1 x Desilter

None - Not requested in RFQ

None - Not requested in RFQ

Does the Rig have a Desander installed and in operative conditions?

None - Not requested in RFQ

None - Not requested in RFQ

None - Not requested in RFQ

None - Not requested in

RFQ

None - Not requested in RFQ

None - Not requested in RFQ

Does the Rig have a Cuttings Auger (conveyor) system?

None - Not requested in RFQ

None - Not requested in

RFQ

None - Not requested in RFQ

None - Not requested in RFQ

To evaluate the Rig's capacities for well control equipment

Yes.1000gpm

Yes> 1000gpm

Brandt DG-101000gpm

Brand D-1000 1000gpm

To evaluate the BOP capacity, Choke & Kill Lines, HCR valves, Manual Valves etc

Single+Double+ Annular

Single+Double+ Annular + Rams pseudo assisted by well pressure

Single+Double+ Annular + Rams

pseudo assisted by well pressure with double valve HCR and Choke Line.

20-3/4" 2k (2 ram) BOP + 2k Annular

& 13-5/8" 10k (3 ram) BOP + 5k Annular

5K BOPs offered in tender

however 10K is available

Note: 5K was requested by Repsol

and 5K stack was offered by Nabors. However Nabors

stated that the can provide a 10k stack

Note: 5K was requested by Repsol

and 5K stack was offered by Nabors. However Nabors

stated that the can provide a 10k stack

Does the rig have a trolley system installed for BOP skidding on/off wellhead to setback deck?

To evaluate the BOP handling system

How many remote choke control consoles does the rig have installed?

To evaluate the Choke manifold characteristics

1 x Rig Floor1 x Living Quart

1 x Rig Floor1 x Pipe Deck

Three (3) remote operating station.

Three (3) remote operating station.

What is the Working Pressure of the Choke & Kill Manifold?

To evaluate the Rig's capacities for well control equipment

Between 3000-3500 Psi

Between 3500-3900 Psi

Between 4000-4500 Psi

10ksi C&K Manifold

How many bottles does the BOP Accumulator have?

To evaluate the capacity to Open - close the BOP'S.

under specification

24 bottles, additional (12)

bottles on board

1x 3,000 PSI 320 gallon twelve station

accumulator. Operates with a

150% operating fluid reserve

1x 3,000 PSI 320 gallon twelve station

accumulator. Operates with a 150% operating fluid reserve

Digital data recording and readout capability for gauge pressures?

To evaluate the Rig's capacities for well control equipment

EVALUATION MATRIX - PLATFORM RIG TENDER

PROJETC TSP 2010-2011 Drilling Campaign GROUP OF EVALUATION HSE, Drilling & Completion, Facility & Construction.

REGION Caribbean

RATING COMPANIES RATING COMPANIES SCORE (Impact x rating) COMMENTS

Question Objective Impact 0 1 2 3 4 5 Baseline ScoreBaseline

AcceptanceH&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

Baseline Score

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

g Is the Rig equipped with a 'Poor Boy' Degasser? 5 No Yes. 3 3 3 3 3 15 15 15 15 15 Yes Yes Yes Yes

h Is the Rig equipped with a Strip Tank? 0 No 0 0 3 3 3 0 0 0 0 0 No strip tank 1 x 10bbls 10bbls 10bbls

i 3 No Yes. 3 3 3 3 3 9 9 9 9 9 Yes Yes Yes

. .

10 Rig Power

a Does the rig have emergency generators? 4 No 1 1 + Back up 3 0 3 0 0 12 0 12 0 0 No emerg. Gens 1 x CAT D399

b 4 No 3 3 3 3 3 12 12 12 12 12

11 Auxiliaries at the rig

a 2 No 3 3 3 4 4 6 6 6 8 8

b Does the rig offer a offline "Buckie" Unit? 0 No Yes 0 0 0 0 0 0 0 0 0 0 None Mentioned None Mentioned None Mentioned None Mentioned

c 1 0 1 2 3 4 >4 3 0 1 3 3 3 0 1 3 3 None Mentioned None Mentioned Yes Yes

d 0 0 1, <500 gpm 2, 500 gpm 2+Back up>500 gpm 0 0 0 0 0 0 0 0 0 0 None Mentioned None Mentioned None - platform rig None - platform rig

12 Helideck

a Does the Rig Contractor supply a helideck? 1 No Yes 3 3 3 3 3 3 3 3 3 3 Specified for S-76

13 Spares

a 3 NO 3 3 3 3 3 9 9 9 9 9

b 3 NO 3 3 3 3 3 9 9 9 9 9

c 3 NO 3 3 3 3 3 9 9 9 9 9

d 3 NO 3 3 3 3 3 9 9 9 9 9

e 3 NO 0 3 3 3 3 3 9 9 9 9 9

IV TECHNICAL PROPOSAL - DRILLING & COMPLETIONS Rating (Sum) = Impact x Score = 930 558.0 572.0 594.0 525.0 564.0

Rating (%) = Score / Criteria = 166.67 100.00 102.51 106.45 94.09 101.08Rating (Q) = Score / Criteria = 5.00 3.00 3.08 3.19 2.82 3.03

To evaluate the Rig's capacities for well control equipment

To evaluate the Rig's capacities for well control equipment

Yes.10bbls

Yes>10bbls

Does the contractor supply a full compliment of 5ksi TIW valves, FOSVs, Grey Valves, IBOPs?

To evaluate the Rig's capacities for well control equipment

Yes. With redundancy

Missing Grey valves

To evaluate the rig power characteristics

No emengency Generators

No emengency Generators

Does thr rig have sufficient rig power capacity (electrical, air, water) for third party services (MWD, mud logging, mud engineering, secondary solids control, cementing unit, E-Line Logging)

To evaluate the rig power capacities

Yes(<2 Parties)

Yes(<3 Parties)

Yes(>5 Parties)

Yes(>7 Parties)

Yes(>8 Parties)

4 x diesel engines driving 4 x 1205kW

generators

3 x diesel engines driving 4

x 930kW generators

4 x diesel engines driving 4 x 1260kW

generators

3 x 1325KW generators

Does the rig contractors package include both fork lift and Crane?

To evaluate the auxiliaries equipment at the rig

Yes.Crane Provided only

Yes.Both Crane & Forklift

SeaTrax 6024 Crane (45T)

2 x 55T Manitex cranes available

2 x Cranes available. One used as a leap

frog crane.

2 x Cranes available. One used as a leap

frog crane.

Does the rig have a device for cleaning (pressure wash)?

To evaluate the auxiliaries equipment at the rig

How many cellar pumps are at the rig and what is their capacity in GPM?

To evaluate the auxiliaries equipment at the rig

To determine the logistics support capabilities of the rig.

Bell 412 & 212 (MOE & CAA

APPROVED in 2007)

50 x 50 for S61, Super Puma or AB

139 helicopter

50 x 50 for S61, Super Puma or AB 139

helicopter

Sufficient spares/inventorty carried for BOP redressing (ram top seals, ram face packers, annular bags)

To evaluate if sufficient spares are available to support any critical equipment failures.

YES. (Has no inventory but a inventory list to

follow)

YES. (Has few inventory items)

YES (Minimal Reuirement)

YES. (Minimal + Extra itmes covered)

YES (Beyond Requirments -

Covers all possible equipment failures)

Section N: Spare Parts in tender

Schedule B1: Spare Parts

(Line 2.12) in tender

Contractor will provide sufficiet

spares as per RFQ.

Contractor will provide sufficiet spares as per

RFQ.

Sufficient spares/inventory carried for Mud Pumps (liners, pistons, pony rods)

To evaluate if sufficient spares are available to support any critical equipment failures.

YES. (Has no inventory but a inventory list to

follow)

YES. (Has few inventory items)

YES (Minimal Reuirement)

YES. (Minimal + Extra itmes covered)

YES (Beyond Requirments -

Covers all possible equipment failures)

Section N: Spare Parts in tender

Schedule B1: Spare Parts

(Line 2.12) in tender

Contractor will provide sufficiet

spares as per RFQ.

Contractor will provide sufficiet spares as per

RFQ.

Sufficient spares/inventory carried for Top Drive (Saver Subs, electricals, solenoids)

To evaluate if sufficient spares are available to support any critical equipment failures.

YES. (Has no inventory but a inventory list to

follow)

YES. (Has few inventory items)

YES (Minimal Reuirement)

YES. (Minimal + Extra itmes covered)

YES (Beyond Requirments -

Covers all possible equipment failures)

Section N: Spare Parts in tender

Schedule B1: Spare Parts

(Line 2.12) in tender

Contractor will provide sufficiet

spares as per RFQ.

Contractor will provide sufficiet spares as per

RFQ.

Sufficient spares/inventory carried for SCR electricals?

To evaluate if sufficient spares are available to support any critical equipment failures.

YES. (Has no inventory but a inventory list to

follow)

YES. (Has few inventory items)

YES (Minimal Reuirement)

YES. (Minimal + Extra itmes covered)

YES (Beyond Requirments -

Covers all possible equipment failures)

Section N: Spare Parts in tender

Schedule B1: Spare Parts

(Line 2.12) in tender

Contractor will provide sufficiet

spares as per RFQ.

Contractor will provide sufficiet spares as per

RFQ.

Sufficient spares/inventory carried for rig's electrical generators?

To evaluate if sufficient spares are available to support any critical equipment failures.

YES. (Has no inventory but a inventory list to

follow)

YES. (Has few inventory items)

YES. (Minimal + Extra itmes covered)

YES (Beyond Requirments -

Covers all possible equipment failures)

Section N: Spare Parts in tender

Schedule B1: Spare Parts

(Line 2.12) in tender

Contractor will provide sufficiet

spares as per RFQ.

Contractor will provide sufficiet spares as per

RFQ.

REPSOL RIG EVALUATION MONTAGE

CATEGORIESOVERVIEW BY CATEGORY

HSSE 1 3+ Passed Paperwork (awaiting details) + Passed Paperwork (awaiting details)

+ 2yrs continuous ops (in tune) - 2yrs non-operating (out of tune) - 6mths non-operating (out of tune) + >5yrs continuous ops (in tune)

+ Active HSE culture on rig - Non-active HSE culture on rig

Logistics 4 2- Long mob/demob timing (Rig in USA)

+ Rig available in Q3 2010 + Rig readily available for hire (Cold Stacked) + Rig available in Q2 2010

+ Rig in T&T + Rig in T&T - Rig in USA - Rig in USA

Performance 3 4- 6mths non-operating (out of tune) + >5yrs continuous operations (in tune)

- Non-active Rig Crews - Non-active Rig Crews

- No drilling experience in TSP. + Extensive drilling experience in TSP. - No drilling experience in TSP.

+ Previously worked with REPSOL Int'l. + Previously worked with REPSOL Int'l. + Previously worked with REPSOL Int'l.

- Rig 'Cold Stacked' - No PMs (6mths) + Active Rig (on contract)

Technical D&C+ All high level drilling criteria met - Minimal drilling criteria met

- Low overpull margin + High overpull margin - Very Low overpull capacity - Low overpull margin

- No emerg. Generators + Emerg. Generators (x2) - No emerg. Generators - No emerg. Generators

+ 3 x Mud Pumps + 3 x Mud Pumps - 2 x Mud Pumps - 2 x Mud Pumps

- Low margin for torque applications + High margin for torque applications + High margin for torque applications + High margin for torque applications

Technical F&C (*)

- Requires platform extensions for rig's living quarters

Rating = Pass / Fail/Disqualified

H&P Rig 203 (2,500 HP) WSM Rig 5 (3,000 HP) Nabors Rig P16 (2,000 HP) Nabors Rig 801 (2,000 HP)

HSSE Yes Yes Yes YesLogistics Yes Yes Yes YesPerformance Yes No No YesTechnical D&C Yes Yes No YesTechnical F&C (*) Disqualified Yes Yes Yes

Rating (Sum) = Impact x Score

H&P Rig 203 (2,500 HP) WSM Rig 5 (3,000 HP) Nabors Rig P16 (2,000 HP) Nabors Rig 801 (2,000 HP)

HSSE 450 315 390 400Logistics 89 93 91 91Performance 145 100 110 125Technical D&C 572 594 525 564Technical F&C (*) 59 100 90 90Rating (Sum)Total 279 255 251 267

Rating (%) = Score / Criteria

H&P Rig 203 (2,500 HP) WSM Rig 5 (3,000 HP) Nabors Rig P16 (2,000 HP) Nabors Rig 801 (2,000 HP)

HSSE 86% 60% 74% 76%Logistics 68% 72% 70% 70%Performance 73% 50% 55% 63%Technical D&C 62% 64% 56% 61%Technical F&C (*) 49% 83% 75% 75%Rating (%) Total 68% 62% 61% 65%

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2,000 HP)

4 2+ Passed Paperwork (awaiting details)

+ Passed Paperwork (awaiting details)

+ Non-active HSE culture on rig; T&T S/Base operations has active HSE culture

+ Active HSE culture on rig; T&T S/Base operations has active HSE culture

1 3+ Short mob/demob timing(Rig in T&T)

+ Short mob/demob timing(Rig in T&T)

- Long mob/demob timing (Rig in USA)

+ Rig readily available for hire (Hot Stacked)

+ Infrastructure established to support operations for last 2 years

+ Well developed infrastructure & network due to being local for >25 years

- Minimal infrastructure currently exists - presently supports non-rig operations (porta camp rentals)

- Minimal infrastructure currently exists - presently supports non-rig operations (porta camp rentals)

1 2+ 2yrs continuous ops(in tune) in T&T.

- 2yrs non-operating(out of tune)

+ Active Rig Crews - currently drilling in T&T.

+ Active Rig Crews - currently drilling in Mexico.

- No drilling experience in TSP; but on SE coast T&T

+ Previously worked High performance with REPSOL Int'l.

- Active Rig (on contract) lower NPT's proved.

- Rig 'Hot Stacked' - Ongoing PMs (2yrs)

2 1 4 2+ Majority of high level drilling criteria met

+ Majority of high level drilling criteria met

4 1 2 2- Rig's gross load exceeds Teak-B capacity(Dead Wt: 5,900kips)

+ Rig's gross load does not exceed Teak-B capacity(Dead Wt: 3,200kips)

+ Rig's gross load does not exceed Teak-B capacity(Dead Wt: 3,600kips)

+ Rig's gross load does not exceed Teak-B capacity(Dead Wt: 3,600kips)

- Exceed PF gross load(Teak-B All. Wt: 5,700kips)

+ Does not exceed PF gross load(Teak-B All. Wt: 5,700kips)

+ Does not exceed PF gross load(Teak-B All. Wt: 5,700kips)

+ Does not exceed PF gross load(Teak-B All. Wt: 5,700kips)

- Requires platform strenghtening for accomodating rig

+ Has been fitted on TSP platforms previously; needs platform extensions

- Requires platform extensions for rig's living quarters

Score >=246 (PASS)Repsol Tender Criteria

Score >=60% (PASS)Repsol Tender Criteria

0

1

2

3

4

5

LEGEND:

H&P Rig 203

WSM Rig 5

Nabors Rig P16

Nabors Rig 801

ACCEPTANCE CRITERIA (3-5)

12

43

12

3

45 5

1

2

3

4

5

1

2

3

4

5

0

100

REPSOL (TRINIDAD) RIG EVALUATION

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2000 HP)

ACCEPTANCE CRITERIA (3-5)

2040

60

140120

10080

2040

6080

100120

140160 160

20

40

60

80

100

120

140

160

20

40

60

80

100

120

140

160

0

1

2

3

4

5

REPSOL (TRINIDAD) RIG EVALUATION

H&P Rig 203 (2,500 HP)

WSM Rig 5 (3,000 HP)

Nabors Rig P16 (2,000 HP)

Nabors Rig 801 (2000 HP)

ACCEPTANCE CRITERIA (3-5)

12

4

3

12

3

4

5 5

1

2

3

4

5

1

2

3

4

5

SUBJECT Campaign Requirements

Hoisting System

Rotary System

Drilling Tubulars

Bulk Storage Capacities

Solids Control Equipment

Well Control Equipment

Rig Power • Rig Air Compressor System: 200 psi

Helideck

Spares /Other

Helmerich and Payne Rig 203

Well Services MarineRig 5

Nabors Drilling Int'lRig PC16

Nabors Drilling Int'lRig 801

• Horsepower: 1,500 - 2,000hp• Mast Rating: 900klbs (Infill H 9-5/8" 13,000ft string).• Drawworks Rating: 900klbs (Infill H 9-5/8" 13,000ft string).• Stand Back Capacity: 20,000ft w/5"DP (430klbs)• API Spec 4F

Highlights:• High horsepower – 2,500hp.

Lowlights:• Mast Rating - 1,000klbs.

Highlights:• High horsepower – 3,000hp. • Mast Rating - 1,200klbs (12 lines). • Stand Back Capacity: 1,200klbs w/5"DP

Lowlights:• None

Highlights:• High horsepower – 2,000hp.

Lowlights:• Mast Rating - 850klbs (12 lines). • Stand Back Capacity: 350klbs w/5"DP (~16,368' x 5" DP)

Highlights:• High horsepower – 2,000hp. • Stand Back Capacity: 650klbs w/5"DP (19,440' x 5" DP)

Lowlights:• Mast Rating - 1,000klbs (12 lines).

• Low TDS torque rating: 30,900ft-lbs (CwD)

Highlights:• None - Standard equipment.

Lowlights:• Low TDS torque rating – 32,500ft-lbs.

Highlights:• Torque (Low Gear): 43,200 ft-lbs

Lowlights:• None

Highlights:• Torque (Low Gear): 42,700 ft-lbs

Lowlights:• None

Highlights:• Torque (Low Gear): 42,700 ft-lbs

Lowlights:• None

• 5-7/8” Drill Pipe - 10,000 ft • 5-7/8” HWDP -15 each• 8” DC -15 each• 3-1/2” Drill Pipe - 15,000 ft • 3-1/2” HWDP -15 each• 4-3/4” DC -15 each• 2-7/8” Drill Pipe - 3,000 ft • Handling Tools for all the above.

• Total Depth: +/-10,000 ft TVD, 16,000 ft MD(approximately)…including 1000’-5000’ horizontal

Highlights:• 20,000' of 5" DP space and jts available.• 30jts x 5" HWDP available.• 24jts x 8" DCs available; 700' x 4-3/4" DC available.• 5,000' x 3-1/2" DP; 900' x 3-1/2" HWDP available.• Full complement of fishing tools available for tubulars provided.

Lowlights:• No 5-7/8" DP, HWDP available.• No 2-7/8" tubing

Highlights:• 13,000ft x 5-7/8" DP available.• 15,000ft 3-1/2" DP available• 3,000ft x 2-7/8" DP available.• 20jts x 5-7/8" HWDP; 20jts x 3-1/2" HWDP available.• 15Jts x 8" DC available.• 24 Jts x 6-1/2" DC; 15Jts x 4-3/4" DC

Lowlights:• Fishing package does not include for 8" DC (6-3/4" largest fishing tubular).

Highlights:• 15,000ft 3-1/2" DP available• 3,000ft 2-7/8" DP available.• 15jts x 8-1/2" DC; 15Jts x 4-3/4" DC

Lowlights:• Limited to 10,000ft x 5" DP • No 5-7/8" DP, HWDP available.• No 6-3/4" DC

Highlights:• 15,000ft 3-1/2" DP available• 3,000ft 2-7/8" DP available.• 15jts x 8-1/2" DC; 15Jts x 4-3/4" DC

Lowlights:• Limited to 10,000ft x 5" DP • No 5-7/8" DP, HWDP available.• No 6-3/4" DC

Rig Floor Peripherals and Accessories

• Iron roughneck and pipe spinner available (for specified tubulars)• Mouse Hole: 2-7/8”-7” diameter; Rotating type• 2 x utility winches (12klbs)• 2 x manriding winches (250kg)

Highlights:• Iron roughneck and pipe spinner available• 4 winches available (2 on drill floor - no mention of manriding ops.)• Rotating mouse hole available.

Lowlights:• None

Highlights:• Iron roughneck and pipe spinner available• Full compliment of subs, crossovers, and well control surface components (TIWs, Grey Valves, IBOPs etc).• Rotating mouse hole available.

Lowlights:• Limited winches (1 ea. for tugger and manriding ops.)

Highlights:• Iron roughneck and pipe spinner available• Rotating mouse hole available• Full compliment of subs, crossovers, and well control surface components (TIWs, Grey Valves, IBOPs etc).• 2 x winches

Lowlights:• None

Highlights:• Iron roughneck and pipe spinner available• Rotating mouse hole available• Full compliment of subs, crossovers, and well control surface components (TIWs, Grey Valves, IBOPs etc).• 2 x winches

Lowlights:• None

Mud Pumps & Circulating System

• Mud capacity: 2,200bbls for max hole volume + 300bbls.• 2 x Mixing Pump (800gpm)

Highlights:• High pump/standpipe working pressure rating: 5,000psi.

Lowlights:• Low mud capacity - 1,475bbls (Active + Res.)• Low trip tank capacity - 30bbls.

Highlights:• Circulating system working pressure rating: 5,000psi / 2100gpm.• Has 3 x Transfer Pumps/Mixing Pumps• Mud Lab available• 2 x Mixing Hoppers

Lowlights:• TOTAL Mud Capacity: 1080bbls (Active + Res.)• Low LCM Pill Pit capacity - 50bbls

Highlights:• Circulating system working pressure rating: 5,000psi / 2100gpm.• Has 3 x Transfer Pumps + 3 x Mixing Pumps• LCM Pill Pit capacity - 100bbls

Lowlights:• TOTAL Mud Capacity: 1317bbls (Active + Res.)• 2 x 1600hP Mud Pumps

Highlights:• Circulating system working pressure rating: 5,000psi.• Has 2 x Transfer Pumps + 3 x Mixing Pumps• LCM Pill Pit capacity - 150bbls

Lowlights:• TOTAL Mud Capacity: 1320bbls (Active + Res.)• 2 x 2000hP Mud Pumps

• Barite capacity: 4,890sxs max in 8.5in hole section (weighting up from 8.8 - 9.5ppg).• Cement capacity: 3,056sxs max required for 13-3/8" cement job. • Water Maker: 500 bbls/day

Highlights:• None.

Lowlights:• Low Barite capacity - 2,400sxs. • Low Cement capacity - 2,400sxs.

Highlights:• Water Maker Capacity: 720bbls/day

Lowlights:• Low Barite Capacity 2500sxs (3000cuft)• Low Cement Capacity 3000sxs (3000cuft)

Highlights:• Water Maker volume @ 500bbls/day

Lowlights:• Low Barite Capacity 2 x 1000cu.ft (2000sxs)• Low Cement Capacity 2 x 1000cu.ft (2000sxs)• Low Bentonite Capacity 1 x 1000cuft (1000cuft)

Highlights:• Water Maker volume @ 500bbls/day

Lowlights:• Low Barite Capacity 2 x 1000cu.ft (2000sxs)• Low Cement Capacity 2 x 1000cu.ft (2000sxs)• Low Bentonite Capacity 1 x 1000cuft (1000cuft)

• Shakers: 3• Mud/Gas Separator: Capacity – Min. 1000 gpm• Desander: Capacity – Min. 1000 gpm• Desilter: Capacity – Min. 1000 gpm• Centrifuges: 2 (High Speed/High Vol; Variable Speed)

Highlights:• 4 x Shale Shakers• 1 x Centifuge• 1 x Desander• 1 x Degasser

Lowlights:• No Dryers• No cuttings conveyor system

Highlights:• 4 x Shale Shakers• 1 x Centifuge• 1 x Desander• 1 x Degasser

Lowlights:• No Dryers• No cuttings conveyor system

Highlights:• None

Lowlights:• No SCE Primary or Secondary Equipment supplied (only mud gas separator provided)

Highlights:• None

Lowlights:• No SCE Primary or Secondary Equipment supplied (only mud gas separator provided)

• Poor Boy Degasser installed (to cover all well control ops).• 13-5/8" 5k BOP (4 ram config with 3k annular preventer).• 2 x Side Outlets (HCR and Manual valves on ea.)• 5k Choke & Kill Manifold

Highlights:• 500psi DiverterChoke & Kill Manifold rated to 10,000psi• 13-5/8" BOP 10,000psi rated system + choke lines.• 20-3/4" BOP 3,000psi rated system• 2 x 5-7/8" Rams available.• Poor Boy Degasser installed

Lowlights:• None

Highlights:• Choke & Kill Manifold rated to 10,000psi• Double type Choke & Kill Manifold• Poor Boy Degasser installed

Lowlights:• 13-5/8" BOPs are 5ksi rating• No 20-3/4" BOP stack available

Highlights:• 10ksi 13-5/8" BOPs (available - not specified on RFQ)• Poor Boy Degasser installed• 21-1/4" 2ksi BOP stack available

Lowlights:• Choke & Kill Manifold rated to 5,000psi (as per RFQ)

Highlights:• 10ksi 13-5/8" BOPs (available - not specified on RFQ)• Poor Boy Degasser installed• 21-1/4" 2ksi BOP stack available

Lowlights:• Choke & Kill Manifold rated to 5,000psi (as per RFQ)

Highlights:• 4 x Caterpillar Diesel engines at 1,476 HP @ 1,200 rpm.• 4 x kato DC Generators at 1205 kW ea. • 5 x Ross Hill FM200 SCR System• Bulk Air System: 120psi Ingersoll-Rand 2 ea.

Lowlights:• No mention of emergency generator.

Highlights:• 4 x 399 Cat Diesel Engines (1100hP)• 4 x GE 5 AT1840761A4 Generators (930kW) • 1 x D399 Cat Diesel Engines (Backup)• 6 x SCR system• Bulk Air System: 120psi Ingersoll-Rand 2 ea.

Lowlights:• None

Highlights:• 4 x 3516B Cat Diesel Engines• 4 x Kato Generators (1260kW ea.) • 4 x SCR system• Bulk Air System: 120psi Quincy QSI-370 2 ea.

Lowlights:• No emergency generators

Highlights:• 3 x 3516B Cat Diesel Engines• 3 x Kato Generators (1325kW ea.) • 5 x SCR system• Bulk Air System: 120psi Quincy QSI-370 2 ea.

Lowlights:• No emergency generators

• Helideck: MOE & CAA Approved• Helicopter type: Bell 212, 412, 422 , Sikorsky S61, Super Puma, and AB 139.• Fixed Foam Fire Fighting System for Helideck• Minimum landing area dimensions: 50 x 50 ft.

Lowlights:• None mentioned.

Highlights:• Helideck available (48ft x 48ft) - Bell 412 & 212 (MOE & CAA APPROVED)• Full fire extinguishing systems (foam) available for helideck

Lowlights:• None

Highlights:• Helideck available (50ft x 50ft) - S-61; Super Puma; AB-139.• Full fire extinguishing systems (foam) available for helideck

Lowlights:• None

Highlights:• Helideck available (50ft x 50ft) - S-61; Super Puma; AB-139.• Full fire extinguishing systems (foam) available for helideck

Lowlights:• None

• Accommodations: 120 persons (fully A/C)

Highlights:• None.

Lowlights:• POB - 44 beds available.

Highlights:• POB: 92 pax

Lowlights:• No highlight of spares criteria.

Highlights:• POB: 120 pax• Sufficient spares provided

Lowlights:• None

Highlights:• POB: 120 pax• Sufficient spares provided

Lowlights:• None

SUBJECT Campaign Requirements

Hoisting System

Rotary System

Bulk Storage Capacities

Solids Control Equipment

Well Control Equipment

Rig Power • Rig Air Compressor System: 200 psi

Spares /Other

Helmerich and Payne Rig 203

Well Services MarineRig 5

Nabors Drilling Int'lRig PC16

Nabors Drilling Int'lRig 801

• Horsepower: 1,500 - 2,000hp• Mast Rating: 900klbs (Infill H 9-5/8" 13,000ft string).• Drawworks Rating: 900klbs (Infill H 9-5/8" 13,000ft string).• Stand Back Capacity: 20,000ft w/5"DP (430klbs)• API Spec 4F

Highlights:• High horsepower – 2,500hp.

Lowlights:• Mast Rating - 1,000klbs.

Mitigating Measures:• Have a ~1,200klbs mast supplied with rig package

Highlights:• High horsepower – 3,000hp. • Mast Rating - 1,200klbs (12 lines).

Lowlights:• None

Highlights:• High horsepower – 2,000hp.

Lowlights:• Mast Rating - 850klbs (12 lines).

Mitigating Measures:• Have a ~1,200klbs mast supplied with rig package

Highlights:• High horsepower – 2,000hp.

Lowlights:• Mast Rating - 1000klbs (12 lines).

Mitigating Measures:• Have a ~1,200klbs mast supplied with rig package

• Low TDS torque rating: 30,900ft-lbs (CwD)

Highlights:• None

Lowlights:• Low TDS torque rating – 32,500ft-lbs.

Mitigating Measures:• Have a higher rated top drive for torque requirements.

Highlights:• TDS Torque (Low Gear): 43,200 ft-lbs

Lowlights:• None

Highlights:• TDS Torque (Low Gear): 42,700 ft-lbs

Lowlights:• None

Highlights:• TDS Torque (Low Gear): 42,700 ft-lbs

Lowlights:• None

Mud Pumps & Circulating System

• Mud capacity: 2,200bbls for max hole volume + 300bbls.• 2 x Mixing Pump (800gpm)

Highlights:• Circulating & Mixing system meets requirements and ratings (5ksi)

Lowlights:• Moderate mud capacity: 1475bbls (Active + Res.)

Mitigating Measures:• Have contractor supply additional mud pits to increase capacity ~2200bbls.

Highlights:• Circulating & Mixing system meets requirements and ratings (5ksi)

Lowlights:• Low Mud Capacity: 1080bbls (Active + Res.)

Mitigating Measures:• Have contractor supply additional mud pits to increase capacity ~2200bbls.

Highlights:• Circulating & Mixing system meets ratings (5ksi)

Lowlights:• Moderate Mud Capacity: 1317bbls (Active + Res.)• Only 2 x 1600hP Mud Pumps

Mitigating Measures:• Mobilise and install 3rd Mud Pump.

• Have contractor supply additional mud pits to increase capacity ~2200bbls.

Highlights:• Circulating & Mixing system meets ratings (5ksi)

Lowlights:• Moderate Mud Capacity: 1320bbls (Active + Res.)• Only 2 x 2000hP Mud Pumps

Mitigating Measures:• Mobilise and install 3rd Mud Pump.

• Have contractor supply additional mud pits to increase capacity ~2200bbls.

• Barite capacity: 4,890sxs max in 8.5in hole section (weighting up from 8.8 - 9.5ppg).• Cement capacity: 3,056sxs max required for 13-3/8" cement job. • Water Maker: 500 bbls/day

Highlights:• None.

Lowlights:• Limited bulk storage (Barite: 2,400sxs; Cement: 2,400sxs)

Mitigating Measures:• Have contractor supply additional silos for barite and cement bulk requirements ~3500 - 4000sxs ea.

Highlights:• None

Lowlights:• Limited bulk storage (Barite: 2,500sxs; Cement: 3000sxs)

Mitigating Measures:• Have contractor supply additional silos for barite and cement bulk requirements ~3500 - 4000sxs ea.

Highlights:• None

Lowlights:• Limited bulk storage (Barite: 2,700sxs; Cement: 2,000sxs)• Low Bentonite Capacity 1 x 1000cuft (1000cuft)

Mitigating Measures:• Have contractor supply additional silos for barite and cement bulk requirements ~3500 - 4000sxs ea.• Utilise Bentonite Tanks for Cement OR Barite.

Highlights:• None

Lowlights:• Limited bulk storage (Barite: 2,700sxs; Cement: 2,000sxs)• Low Bentonite Capacity 1 x 1000cuft (1000cuft)

Mitigating Measures:• Have contractor supply additional silos for barite and cement bulk requirements ~3500 - 4000sxs ea.• Utilise Bentonite Tanks for Cement OR Barite.

• Shakers: 3• Mud/Gas Separator: Capacity – Min. 1000 gpm• Desander: Capacity – Min. 1000 gpm• Desilter: Capacity – Min. 1000 gpm• Centrifuges: 2 (High Speed/High Vol; Variable Speed)

Highlights:• Full compliment of SCE Primary & Secondary Equipment

Lowlights:• None

Highlights:• Full compliment of SCE Primary & Secondary Equipment

Lowlights:• None

Highlights:• None

Lowlights:• No SCE Primary or Secondary Equipment supplied

Mitigating Measures:• Have contractor supply SCE equipment.

Highlights:• None

Lowlights:• No SCE Primary or Secondary Equipment supplied

Mitigating Measures:• Have contractor supply SCE equipment.

• Poor Boy Degasser installed (to cover all well control ops).• 13-5/8" 5k BOP (4 ram config with 3k annular preventer).• 2 x Side Outlets (HCR and Manual valves on ea.)• 5k Choke & Kill Manifold

Highlights:• 13-5/8" BOP 10ksi rated system + choke lines.• 20-3/4" BOP 3ksi rated system• Downstream 10ksi well control equipment

Lowlights:• None

Highlights:• Downstream 10ksi well control equipment

Lowlights:• 13-5/8" BOPs are 5ksi rating• No 20-3/4" BOP stack available

Mitigating Measures:• Have contractor supply 13-5/8" 10ksi and 20-3/4" 3ksi BOPs (confirmed already available)

Highlights:• 13-5/8" BOP 10ksi rated system + choke lines.• 21-1/4" 2ksi BOP stack available

Lowlights:• Choke & Kill Manifold rated to 5ksi

Mitigating Measures:• Have contractor upgrade downstream well control equipment to 10ksi.

Highlights:• 13-5/8" BOP 10ksi rated system + choke lines.• 21-1/4" 2ksi BOP stack available

Lowlights:• Choke & Kill Manifold rated to 5ksi

Mitigating Measures:• Have contractor upgrade downstream well control equipment to 10ksi.

Highlights:• Full rig electrical & power systems

Lowlights:• No mention of emergency generator.

Mitigating Measures:• Have contractor supply emergency generators

Highlights:• Full rig electrical & power systems

Lowlights:• None

Highlights:• Full rig electrical & power systems

Lowlights:• No emergency generators

Mitigating Measures:• Have contractor supply emergency generators

Highlights:• Full rig electrical & power systems

Lowlights:• No emergency generators

Mitigating Measures:• Have contractor supply emergency generators

• Accommodations: 120 persons (fully A/C)

Highlights:• None.

Lowlights:• POB: 44 pax

Mitigating Measures:• Have contractor supply additional accomodations for ~100pax

Highlights:• POB: 92 pax

Lowlights:• None

Highlights:• POB: 120 pax

Lowlights:• None

Highlights:• POB: 120 pax

Lowlights:• None