Vibration Transfer Mobility Measurements using MLS Herb Singleton [email protected] October 19, 2005

Transcript of 2005 Noisecon Presentation

Vibration Transfer MobilityMeasurements using MLS

Herb Singleton

[email protected]

October 19, 2005

FTA Vibration Impact Guidelines

• FTA/FRA vibration impact

assessment

• Vibration propagation

measurement

www.Cross-Spectrum.com | 2/22

Transfer Mobility Measurement

• Instrumented hammer to generate vibration

• Accelerometers measure ground vibration

• Transfer function calculated using FFT techniques

InstrumentedHammer Surface-mounted Accelerometers

Vibration Transmitted Through Ground

www.Cross-Spectrum.com | 3/22

Current Apparatus

www.Cross-Spectrum.com | 4/22

Vibration Propagation Data

Vol

ts

Time, secs

www.Cross-Spectrum.com | 5/22

It Works, But...

• Physically intensive

– Lift/drop weight 300 times per site

– Move rig 11 times per site

• Custom fabricated

– Expensive to repair

• Costly Process

– 2-3 consultants to operate

– High shipping costs (110 lbs)

• Noise-sensitive

– Vibration from traffic, machinery, etc can corrupt data

www.Cross-Spectrum.com | 6/22

Desired improvements:

• Better test signals

• Better equipment

www.Cross-Spectrum.com | 7/22

Desired improvements:

• Better test signals

– Maximum Length Sequence (MLS)

• Better equipment

– Tactile Transducer

www.Cross-Spectrum.com | 8/22

Maximum Length Sequence

• Pseudo-random binary sequence

Gives impulse under circular auto correlation

www.Cross-Spectrum.com | 9/22

MLS Advantages

• High signal-to-noise ratio

→ No averaging of multiple runs

• High noise immunity

→ No repeating of measurements contaminated by cars,

pedestrian traffic, etc

Same data, less effort!

www.Cross-Spectrum.com | 10/22

Noise Immunity

Vol

ts

Sample #

www.Cross-Spectrum.com | 11/22

Tactile Transducer

• Magnetic coil/moving mass

shaker

• Used in home audio &

specialized training

applications

• Approx 1 lbf/W

• Mounted on load cell to

calibrate force signal

www.Cross-Spectrum.com | 12/22

Shaker System

• Car audio amplifier/12V battery

• Laptop computer w/ DAQ card

• 65535-pt MLS signal at 1000 Hz sampling rate

Computer/DAQ

65535-ptMLS

TactileTransducer

Load CelAccelerometers

MLS-Force

GroundVibration

Calibration Signal

PowerAmplifier

www.Cross-Spectrum.com | 13/22

Measurement Layout

25 ft

50 ft

75 ft

100 ft

125 ft

150 ft

Accelerometer Array

125-ft slant dist.

168-f

t slan

t dist.

25-ft slant dist.

-7-75f

X X X X X X X X X X X-75 ft -60 ft -45 ft -30 ft -15 ft 0 ft 15 ft 30 ft 45 ft 60 ft 75 ft

Impact Line

X Impact Position

Accelerometer Position

www.Cross-Spectrum.com | 14/22

Measurement Comparison (Best Case)

www.Cross-Spectrum.com | 15/22

Measurement Comparison (Worst Case)

www.Cross-Spectrum.com | 16/22

Coherence

• Used to determine if measured output is related to input

→ Data integrity

• Function of frequency

• Defined for 2-channel measurements

• Coherence value = 0 to 1

www.Cross-Spectrum.com | 17/22

Coherence

www.Cross-Spectrum.com | 18/22

MLS Coherence

• MLS is a time-domain operation

• Rife & Vanderkooy defined MLS ‘Coherence’:

→ Ratio of energy in analysis window to energy in the

entire impulse response

www.Cross-Spectrum.com | 19/22

MLS Coherence

Vol

ts

Sample #

www.Cross-Spectrum.com | 20/22

MLS Coherence

www.Cross-Spectrum.com | 21/22

The End!

• New method for measurement vibration transfer mobility

– Tactile transfer: inexpensive, lightweight, non-proprietary

– MLS: proven, reliable test stimulus

• Data and error checking comparable to impact/winch

method

• Potential for specialized measurements

• Much easier on the back and the wallet

www.Cross-Spectrum.com | 22/22