2005 Noisecon Presentation
Transcript of 2005 Noisecon Presentation
FTA Vibration Impact Guidelines
• FTA/FRA vibration impact
assessment
• Vibration propagation
measurement
www.Cross-Spectrum.com | 2/22
Transfer Mobility Measurement
• Instrumented hammer to generate vibration
• Accelerometers measure ground vibration
• Transfer function calculated using FFT techniques
InstrumentedHammer Surface-mounted Accelerometers
Vibration Transmitted Through Ground
www.Cross-Spectrum.com | 3/22
It Works, But...
• Physically intensive
– Lift/drop weight 300 times per site
– Move rig 11 times per site
• Custom fabricated
– Expensive to repair
• Costly Process
– 2-3 consultants to operate
– High shipping costs (110 lbs)
• Noise-sensitive
– Vibration from traffic, machinery, etc can corrupt data
www.Cross-Spectrum.com | 6/22
Desired improvements:
• Better test signals
– Maximum Length Sequence (MLS)
• Better equipment
– Tactile Transducer
www.Cross-Spectrum.com | 8/22
Maximum Length Sequence
• Pseudo-random binary sequence
Gives impulse under circular auto correlation
www.Cross-Spectrum.com | 9/22
MLS Advantages
• High signal-to-noise ratio
→ No averaging of multiple runs
• High noise immunity
→ No repeating of measurements contaminated by cars,
pedestrian traffic, etc
Same data, less effort!
www.Cross-Spectrum.com | 10/22
Tactile Transducer
• Magnetic coil/moving mass
shaker
• Used in home audio &
specialized training
applications
• Approx 1 lbf/W
• Mounted on load cell to
calibrate force signal
www.Cross-Spectrum.com | 12/22
Shaker System
• Car audio amplifier/12V battery
• Laptop computer w/ DAQ card
• 65535-pt MLS signal at 1000 Hz sampling rate
Computer/DAQ
65535-ptMLS
TactileTransducer
Load CelAccelerometers
MLS-Force
GroundVibration
Calibration Signal
PowerAmplifier
www.Cross-Spectrum.com | 13/22
Measurement Layout
25 ft
50 ft
75 ft
100 ft
125 ft
150 ft
Accelerometer Array
125-ft slant dist.
168-f
t slan
t dist.
25-ft slant dist.
-7-75f
X X X X X X X X X X X-75 ft -60 ft -45 ft -30 ft -15 ft 0 ft 15 ft 30 ft 45 ft 60 ft 75 ft
Impact Line
X Impact Position
Accelerometer Position
www.Cross-Spectrum.com | 14/22
Coherence
• Used to determine if measured output is related to input
→ Data integrity
• Function of frequency
• Defined for 2-channel measurements
• Coherence value = 0 to 1
www.Cross-Spectrum.com | 17/22
MLS Coherence
• MLS is a time-domain operation
• Rife & Vanderkooy defined MLS ‘Coherence’:
→ Ratio of energy in analysis window to energy in the
entire impulse response
www.Cross-Spectrum.com | 19/22
The End!
• New method for measurement vibration transfer mobility
– Tactile transfer: inexpensive, lightweight, non-proprietary
– MLS: proven, reliable test stimulus
• Data and error checking comparable to impact/winch
method
• Potential for specialized measurements
• Much easier on the back and the wallet
www.Cross-Spectrum.com | 22/22