200 / 300 SERIES PANELS F.O. INTERIOR PARTITION CI-FO-06-200/300 O.H. DOOR HEAD WITH DRIP EDGE...

43
INDEX SHEET 200 / 300 SERIES PANELS CI-DS-01-200/300 C & I DISCLAIMER CI-PP-01-200 PANEL PROFILES 200 SERIES CI-PP-02-300 PANEL PROFILES 300 SERIES CI-PJ-01-200 200 EXPANDED PANEL JOINT CI-PJ-02-200 200 ENGAGED PANEL JOINT CI-PJ-03-300 300 EXPANDED PANEL JOINT CI-PJ-04-300 300 ENGAGED PANEL JOINT CI-PJ-05-200/300 INTERMEDIATE SUPPORT CI-BS-01-200/300 BASE DETAIL - FLUSH CI-BS-02-200/300 BASE DETAIL - NOTCHED CONCRETE CI-BS-03-200/300 BASE DETAIL - OVERHANG W/ DRIP CI-BS-04-200/300 BASE DETAIL - OVERHANG W/ SUPPORT CI-BS-05-200/300 BASE DETAIL - MARRIAGE BEAD ISOMETRIC CI-OC-01-200/300 OUTSIDE CORNER WITH PROFILED TRIM CI-OC-02-200/300 OUTSIDE CORNER WITH FLAT TRIM CI-IC-01-200/300 INSIDE CORNER WITH PROFILED TRIM CI-IC-02-200/300 INSIDE CORNER WITH FLAT TRIM CI-FO-01-200/300 F.O. HEAD WITH DRIP EDGE CI-FO-02-200/300 F.O. TWO PIECE JAMB CI-FO-03-200/300 F.O. ONE PIECE JAMB CI-FO-04-200/300 F.O. ONE PIECE SILL CI-FO-05-200/300 F.O. INTERIOR PARTITION CI-FO-06-200/300 O.H. DOOR HEAD WITH DRIP EDGE CI-FO-07-200/300 O.H. DOOR TWO PIECE JAMB

Transcript of 200 / 300 SERIES PANELS F.O. INTERIOR PARTITION CI-FO-06-200/300 O.H. DOOR HEAD WITH DRIP EDGE...

INDEX SHEET

200 / 300 SERIES PANELS

CI-DS-01-200/300 C & I DISCLAIMER

CI-PP-01-200 PANEL PROFILES 200 SERIES

CI-PP-02-300 PANEL PROFILES 300 SERIES

CI-PJ-01-200 200 EXPANDED PANEL JOINT

CI-PJ-02-200 200 ENGAGED PANEL JOINT

CI-PJ-03-300 300 EXPANDED PANEL JOINT

CI-PJ-04-300 300 ENGAGED PANEL JOINT

CI-PJ-05-200/300 INTERMEDIATE SUPPORT

CI-BS-01-200/300 BASE DETAIL - FLUSH

CI-BS-02-200/300 BASE DETAIL - NOTCHED CONCRETE

CI-BS-03-200/300 BASE DETAIL - OVERHANG W/ DRIP

CI-BS-04-200/300 BASE DETAIL - OVERHANG W/ SUPPORT

CI-BS-05-200/300 BASE DETAIL - MARRIAGE BEAD ISOMETRIC

CI-OC-01-200/300 OUTSIDE CORNER WITH PROFILED TRIM

CI-OC-02-200/300 OUTSIDE CORNER WITH FLAT TRIM

CI-IC-01-200/300 INSIDE CORNER WITH PROFILED TRIM

CI-IC-02-200/300 INSIDE CORNER WITH FLAT TRIM

CI-FO-01-200/300 F.O. HEAD WITH DRIP EDGE

CI-FO-02-200/300 F.O. TWO PIECE JAMB

CI-FO-03-200/300 F.O. ONE PIECE JAMB

CI-FO-04-200/300 F.O. ONE PIECE SILL

CI-FO-05-200/300 F.O. INTERIOR PARTITION

CI-FO-06-200/300 O.H. DOOR HEAD WITH DRIP EDGE

CI-FO-07-200/300 O.H. DOOR TWO PIECE JAMB

INDEX SHEET

200 / 300 SERIES PANELS

CI-SJ-01-200/300 STACK JOINT

CI-SJ-01-200/300 STACK JOINT - ALTERNATE

CI-PR-01-200/300 PARAPET WITH FLUSH TRIM

CI-PR-02-200/300 PARAPET WITH PROFILED TRIM

CI-WR-01-200/300 WALL TO ROOF

CI-WR-02-200/300 CONTINUOUS WALL AT ROOF / CANOPY

CI-PE-01-200/300 PIPE PENETRATION

CI-PE-02-200/300 PIPE PENETRATION ISOMETRIC

CI-PE-03-200/300 KNIFE PENETRATION

CI-PE-04-200/300 KNIFE PENETRATION ISOMETRIC

CI-PE-05-200/300 BEAM PENETRATION

CI-PE-06-200/300 BEAM PENETRATION ISOMETRIC

CI-TL-01-200/300 TRIM END LAP

CI-TL-02-200/300 TRIM END LAP WITH HEM

CI-TL-03-200/300 TRIM END LAP WITH LAP STRIP

CI-TL-04-200/300 TRIM LAP AT FRAMED OPENINGS -

ISOMETRIC

CI-TL-05-200/300 TRIM LAP AT FRAMED OPENINGS -

EXPLODED VIEW

200 / 300 SERIES PANELS

COMMERCIAL/INDUSTRIAL

DISCLAIMER

DISCLAIMER:

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED

COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED

ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR

BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).

PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY

REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES

FOR SPECIFIC PROJECT RECOMMENDATIONS.

CORE DEPTHS:

2", 2.5", 3", 4", 5", 6"

42" COVERAGE (1,067mm)

2"-6"

42" COVERAGE (1,067mm)

2"-6"

42" COVERAGE (1,067mm)

200 SERIES PANEL (DELAND)

MINOR RIB

INVERTED RIB

SHADOWLINE

INVERTED RIB

"V" GROOVE

INVERTED RIB

2"-6"200 SERIES PANEL (MODESTO)

STEEL GAUGES:

EXTERIOR: 26, 24, 22

INTERIOR: 26, 24, 22

MODULE WIDTH: 42"

PANEL ORIENTATION: VERTICAL

EMBOSSING:

EXTERIOR: STUCCO / SMOOTH

INTERIOR: STUCCO / SMOOTH

LENGTHS:

MINIMUM: 8'-0"

MAXIMUM: 53'-0"

200 SERIES PANEL (MODESTO)

EXTERIOR

INTERIOR

EXTERIOR

INTERIOR

EXTERIOR

INTERIOR

200 / 300 SERIES PANELS

PANEL PROFILES

200 SERIES

2"-6"

42" COVERAGE (1,067mm)

300SL SERIES PANEL (DELAND)

MINOR RIB

2"-6"

42" COVERAGE (1,067mm)

300MR SERIES PANEL (DELAND)

MICRO-RIB

2"-6"

42" COVERAGE (1,067mm)

300SR SERIES PANEL (MODESTO)

STRIATED

2"-6"

42" COVERAGE (1,067mm)

300A SERIES PANEL (DELAND)

SHADOWLINE, MINOR RIB, V-GROOVE

AZTECO

CORE DEPTHS:

DELAND: 2", 2.5", 3", 4", 5", 6"

STEEL GAUGES:

EXTERIOR: 26, 24, 22

INTERIOR: 26, 24, 22

MODULE WIDTH: 42"

PANEL ORIENTATION: VERTICAL

EMBOSSING:

EXTERIOR: STUCCO / SMOOTH

INTERIOR: STUCCO / SMOOTH

LENGTHS:

MINIMUM: 8'-0"

MAXIMUM: 53'-0"

EXTERIOR

INTERIOR

EXTERIOR

INTERIOR

EXTERIOR

INTERIOR

SHADOWLINE, MINOR RIB, V-GROOVE

SHADOWLINE, MINOR RIB, V-GROOVE

SHADOWLINE, MINOR RIB, V-GROOVE

EXTERIOR

INTERIOR

200 / 300 SERIES PANELS

PANEL PROFILES

300 SERIES

WALL PANEL INSTALLATION DIRECTION

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER SUPPORT)

SET CLIP IN BUTYL SEALANT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

CONTINUOUS

BUTYL SEALANT

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT (OPTIONAL)

MALE LEG FEMALE POCKET

MALE LEG

FEMALE POCKET

NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL

200 / 300 SERIES PANELS

200 EXPANDED

PANEL JOINT

WALL PANEL INSTALLATION DIRECTION

CONTINUOUS BUTYL SEALANT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT (OPTIONAL)

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER SUPPORT)

SET CLIP IN BUTYL SEALANT

200 / 300 SERIES PANELS

200 ENGAGED

PANEL JOINT

WALL PANEL INSTALLATION DIRECTION

CONTINUOUS

BUTYL SEALANT

MALE LEG FEMALE POCKET

MALE LEG

FEMALE POCKET

NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

14 GA. GALVANIZED 2-HOLE

HIDDEN CLIP

(1 PER PANEL, PER SUPPORT)

SET CLIP IN BUTYL SEALANT

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT (OPTIONAL)

200 / 300 SERIES PANELS

300 EXPANDED

PANEL JOINT

FEMALE JOINT MALE JOINT

WALL PANEL INSTALLATION DIRECTION

(2) -

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

CONTINUOUS BUTYL SEALANT

14 GA. GALVANIZED 2-HOLE

HIDDEN CLIP

(1 PER PANEL, PER SUPPORT)

SET CLIP IN BUTYL SEALANT

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT (OPTIONAL)

200 / 300 SERIES PANELS

300 ENGAGED

PANEL JOINT

(2) -

1

4

" HEX HEAD FASTENERS

PER PANEL CLIP

1

4

5

°

3"

.75 .75

Ø 0.28"

.7

2

14 GA. GALVANIZED 2-HOLE HIDDEN CLIP

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER SUPPORT)

SET CLIP IN BUTYL SEALANT

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

1 .50"

.3

6

200 / 300 SERIES PANELS

INTERMEDIATE

SUPPORT

BASE TRIM

FASTENER TO CONCRETE

(NOT BY KINGSPAN)

POP RIVETS @

8" O.C.

BASE FLASHING SET

IN CONTINUOUS BED

OF BUTYL SEALANT

NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL

TRIM LAP INSTRUCTIONS

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

MIN 16 GA. GALVANIZED

BASE ANGLE WITH MINIMUM 3"

BEARING SURFACE FOR PANEL

FASTENING (NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

SET ANGLE IN BED OF SEALANT

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

BASE DETAIL - FLUSH

BASE TRIM

1

1

2

"

(T

YP

.)

NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL

TRIM LAP INSTRUCTIONS

POP RIVETS @

8" O.C.

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

BASE FLASHING SET

IN CONTINUOUS BED

OF BUTYL SEALANT

FASTENER TO CONCRETE

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

MIN 16 GA. GALVANIZED

BASE ANGLE WITH MINIMUM 3"

BEARING SURFACE FOR PANEL

FASTENING (NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

SET ANGLE IN BED OF SEALANT

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

BASE DETAIL - NOTCHED

CONCRETE

BASE TRIM

1

1

2

"

(T

YP

.)

NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL

TRIM LAP INSTRUCTIONS

BASE FLASHING

POP RIVETS @

8" O.C.

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

MIN 16 GA. GALVANIZED

BASE ANGLE WITH MINIMUM 3"

BEARING SURFACE FOR PANEL

FASTENING (NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

SET ANGLE IN BED OF SEALANT

(NOT BY KINGSPAN)

FASTENER TO CONCRETE

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

BASE DETAIL -

OVERHANG W/ DRIP

BASE TRIM

1

1

2

"

(T

YP

.)

NOTE: SEE DETAIL CI-TL-01-200/300 AND CI-TL-02-200/300 FOR TYPICAL

TRIM LAP INSTRUCTIONS

POP RIVETS @

8" O.C.

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

SET ANGLE IN BED OF SEALANT

(NOT BY KINGSPAN)

FASTENER TO CONCRETE

(NOT BY KINGSPAN)

BASE FLASHING SET

IN CONTINUOUS BED

OF BUTYL SEALANT

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

MIN 16 GA. GALVANIZED

BASE ANGLE WITH MINIMUM 3"

BEARING SURFACE FOR PANEL

FASTENING (NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

200 / 300 SERIES PANELS

BASE DETAIL -

OVERHANG W/

OPTIONAL SUPPORT

NOTE:

ENSURE THERE ARE NO

GAPS IN SEALANT BEAD.

COVERAGE MUST BE

CONTINUOUS

MARRIAGE BEAD TO VERTICAL JOINT

(FEMAILE INTERIOR JOINT TO HAVE EITHER

FACTORY OR FIELD CONTINUOUS BUTYL

SEALANT)

BASE FLASHING

CONTINUOUS HEAVY BEAD

OF BUTYL SEALANT

PANEL CLIP TO BE SET IN BED OF BUTYL

SEALANT

14 GA. GALVANIZED 2-HOLE

HIDDEN CLIP

(1 PER PANEL, PER SUPPORT)

MIN 16 GA. GALVANIZED

BASE ANGLE SET IN BED OF

SEALANT (NOT BY KINGSPAN)

200 / 300 SERIES PANELS

BASE DETAIL -

MARRIAGE BEAD

ISOMETRIC

OUTSIDE CORNER TRIM

POP RIVETS @

8" O.C.

3

4

" PHIL. PAN HEAD @ 8" O.C.

INSIDE CORNER TRIM

CONTINUOUS

BUTYL SEALANT

WIL

L V

AR

Y W

IT

H

FIE

LD

C

ON

DIT

IO

N

WILL VARY WITH

FIELD CONDITION

FIELD CUT

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

EXPANDABLE

INSULATION AS REQUIRED

(NOT BY KINGSPAN)

1

4

" - THROUGH FASTENERS

W/ 1

1

8

" BONDED WASHER

(AS REQUIRED FOR WIND LOAD)

ATTACHMENT CLIP

(NOT BY KINGSPAN)

CONTINUOUS

BUTYL TAPE / SEALANT

CONTINUOUS

BUTYL TAPE /

SEALANT

3

4

" PHIL. PAN HEAD @ 8" O.C.

1

4

" - THROUGH FASTENERS W/

1

1

8

" BONDED WASHER (AS

REQUIRED FOR WIND LOAD)

200 / 300 SERIES PANELS

OUTSIDE CORNER

WITH PROFILED TRIM

WIL

L V

AR

Y W

IT

H

FIE

LD

C

ON

DIT

IO

N

WILL VARY WITH

FIELD CONDITION

FIELD CUT

OUTSIDE CORNER TRIM

POP RIVETS @

8" O.C.

3

4

" PHIL. PAN HEAD @ 8" O.C.

INSIDE CORNER TRIM

CONTINUOUS

BUTYL SEALANT

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

F.I.P. INSULATION

AS REQUIRED

(BY OTHERS)

ATTACHMENT CLIP

(NOT BY KINGSPAN)

CONTINUOUS

BUTYL TAPE / SEALANT

CONTINUOUS

BUTYL TAPE /

SEALANT

3

4

" PHIL. PAN HEAD @ 8" O.C.

1

4

" - "LOW PROFILE"

THROUGH FASTENER

W/ 1

1

8

" BONDED WASHER

(AS REQUIRED FOR WIND LOAD)

1

4

" - "LOW PROFILE" THROUGH

FASTENER W/ 1

1

8

" BONDED

WASHER (AS REQUIRED FOR

WIND LOAD)

200 / 300 SERIES PANELS

OUTSIDE CORNER

WITH FLAT TRIM

3

4

" PHIL. PAN HEAD

@ 8" O.C.

OUTSIDE CORNER TRIM

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

POP RIVETS

8" O.C.

EXPANDABLE

INSULATION AS REQUIRED

(NOT BY KINGSPAN)

1

4

" - THROUGH FASTENERS

W/ 1

1

8

" BONDED WASHER

(AS REQUIRED FOR WIND

LOAD)

CONTINUOUS BUTYL

SEALANT

CONTINUOUS

BUTYL SEALANT

3

4

" PHIL. PAN HEAD

@ 8" O.C.

CONTINUOUS BUTYL

SEALANT

WIL

L V

AR

Y W

IT

H

FIE

LD

C

ON

DIT

IO

N

WILL VARY WITH

FIELD CONDITION

FIELD CUT

CONTINUOUS BUTYL

SEALANT

INSIDE CORNER TRIM

POP RIVETS

8" O.C.

1

4

" - THROUGH

FASTENERS W/ 1

1

8

"

BONDED WASHER (AS

REQUIRED FOR WIND

LOAD)

200 / 300 SERIES PANELS

INSIDE CORNER

WITH PROFILED TRIM

WIL

L V

AR

Y W

IT

H

FIE

LD

C

ON

DIT

IO

N

WILL VARY WITH

FIELD CONDITION

FIELD CUT

3

4

" PHIL. PAN HEAD

@ 8" O.C.

OUTSIDE CORNER TRIM

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

POP RIVETS

8" O.C.

CONTINUOUS BUTYL

SEALANT

CONTINUOUS

BUTYL SEALANT

3

4

" PHIL. PAN HEAD

@ 8" O.C.

CONTINUOUS BUTYL

SEALANT

CONTINUOUS BUTYL

SEALANT

INSIDE CORNER TRIM

POP RIVETS

8" O.C.

1

4

" - "LOW PROFILE"

THROUGH FASTENER

W/ 1

1

8

" BONDED WASHER

(AS REQUIRED FOR WIND

LOAD)

1

4

" - "LOW PROFILE"

THROUGH FASTENER

W/ 1

1

8

" BONDED WASHER

(AS REQUIRED FOR WIND

LOAD)

EXPANDABLE

INSULATION AS REQUIRED

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

INSIDE CORNER

WITH FLAT TRIM

EXTERIOR CAP TRIM

1

4

" - "LOW PROFILE"

THROUGH FASTENER

@ 12" O.C.

EXPOSED SEALANT

(NOT BY KINGSPAN)

DRIP FLASHING

FRAMED OPENING

(NOT BY KINGSPAN)

DOOR/WINDOW FRAME

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT

BOTH SIDES OF TRIM W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300

FOR TYPICAL TRIM LAP INSTRUCTIONS

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

POP RIVETS

8" O.C.

200 / 300 SERIES PANELS

FRAMED OPENING

HEAD W/ "DRIP EDGE"

INTERIOR CAP TRIM

1

4

" - "LOW PROFILE"

THROUGH FASTENER

@ 12" O.C.

CONTINUOUS BUTYL SEALANT

BOTH SIDES OF TRIM

FRAMED OPENING

(NOT BY KINGSPAN)

EXTERIOR CAP TRIM

DOOR/WINDOW FRAME

(NOT BY KINGSPAN)

EXPOSED SEALANT

(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300

FOR TYPICAL TRIM LAP INSTRUCTIONS

POP RIVETS

8" O.C.

POP RIVETS 8" O.C.

CONTINUOUS BUTYL

SEALANT

CONTINUOUS BUTYL SEALANT

200 / 300 SERIES PANELS

FRAMED OPENING

TWO PIECE JAMB

FRAMED OPENING

(NOT BY KINGSPAN)

DOOR/WINDOW FRAME

(NOT BY KINGSPAN)

EXPOSED SEALANT

(NOT BY KINGSPAN)

1

4

" - "LOW PROFILE"

THROUGH FASTENER

WASHER @ 12" O.C.

CONTINUOUS BUTYL SEALANT

1

4

" - 14 "LOW PROFILE"

FASTENER (AS REQUIRED)

NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300

FOR TYPICAL TRIM LAP INSTRUCTIONS

CONTINUOUS BUTYL SEALANT

CAP TRIM

POP RIVETS 8" O.C.

CONTINUOUS BUTYL SEALANT

200 / 300 SERIES PANELS

FRAMED OPENING

ONE PIECE JAMB

EXTERIOR CAP TRIM,

SLOPE TRIM FOR POSITIVE

DRAINAGE. SLOPE AND SIZE OF

TRIM TO BE DETERMINED BY

OTHERS (NOT BY KINGSPAN)

1

4

" - "LOW PROFILE"

THROUGH FASTENER

@ 12" O.C.

FRAMED OPENING

(NOT BY KINGSPAN)

DOOR/WINDOW FRAME

(NOT BY KINGSPAN)

EXPOSED SEALANT

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT

W/ MARRIAGE BEAD TO

VERTICAL PANEL JOINT

1

4

" - "LOW PROFILE"

FASTENER (AS

REQUIRED)

CONTINUOUS BUTYL

SEALANT

NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300

FOR TYPICAL TRIM LAP INSTRUCTIONS

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

SLO

PE

POP RIVETS

8" O.C.

FIELD CUT PANEL TO SLOPE

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

FRAMED OPENING

ONE PIECE SILL

CAP TRIM

CONTINUOUS BUTYL SEALANT

CAP TRIM

CONTINUOUS BUTYL SEALANT

CONTRACTOR MAY REMOVE A PORTION

OF THE FOAM CORE AND INSERT TREATED

LUMBER TO REINFORCE LARGE OPENINGS

CAP TRIM

CONTRACTOR MAY REMOVE A PORTION

OF THE FOAM CORE AND INSERT TREATED

LUMBER TO REINFORCE LARGE OPENINGS

DOOR CASING

(NOT BY KINGSPAN)

THROUGH BOLT AS

REQUIRED FOR ATTACHMENT

OF DOOR CASING

(NOT BY KINGSPAN)

CONTINUOUS

BUTYL SEALANT

3

4

" PHIL. PAN HEAD

3

4

" PHIL. PAN HEAD

DOOR CASING

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

FRAMED OPENING

PARTITION

EXTERIOR CAP TRIM

DRIP FLASHING

FRAMED OPENING

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT

W/ MARRIAGE BEAD TO

VERTICAL PANEL JOINT

FASTENER

(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300

FOR TYPICAL TRIM LAP INSTRUCTIONS

HEADER TRIM

(OPTIONAL)

TRIM INSTALLATION SEQUENCE:

1 HEADER TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS

2 DRIP FLASHING & ALL APPLICABLE SEALANTS PRIOR TO

INSTALLING THE PANEL AND THROUGH FASTENERS

3 EXTERIOR CAP TRIM

1

2

3

1

4

" - "LOW PROFILE"

THROUGH FASTENER

@ 12" O.C.

EXPOSED SEALANT

(NOT BY KINGSPAN)

POP RIVETS

8" O.C.

200 / 300 SERIES PANELS

OVERHEAD DOOR

HEAD W/ DRIP EDGE

INTERIOR CAP TRIM

1

4

" - "LOW PROFILE"

THROUGH FASTENER

@ 12" O.C.

CONTINUOUS BUTYL SEALANT

BOTH SIDES OF TRIM

FRAMED OPENING

(NOT BY KINGSPAN)

EXTERIOR CAP TRIM

EXPOSED SEALANT

(NOT BY KINGSPAN)

FASTENER

(NOT BY KINGSPAN)

JAMB TRIM

(OPTIONAL)

NOTE: SEE DETAIL CI-TL-01-200/300, CI-TL-02-200/300, AND CI-TL-04-200/300

FOR TYPICAL TRIM LAP INSTRUCTIONS

TRIM INSTALLATION SEQUENCE:

1 JAMB TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS

2 INTERIOR CAP TRIM & ALL APPLICABLE SEALANTS PRIOR TO

INSTALLING THE PANEL AND THROUGH FASTENERS

3 EXTERIOR CAP TRIM

1

2

3

POP RIVETS 8" O.C.

POP RIVETS

8" O.C. (UNLESS NOTED OTHERWISE)

CONTINUOUS BUTYL

SEALANT

CONTINUOUS BUTYL SEALANT

200 / 300 SERIES PANELS

OVERHEAD DOOR

TWO-PIECE JAMB

STACK TRIM

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

CONTINUOUS 3" X 3" ANGLE

(GAUGE TO MATCH GIRT)

(NOT BY KINGSPAN)

POP RIVETS

8" O.C.

STACK FLASHING

CONTINUOUS BUTYL

SEALANT BELOW BASE

FLASHING

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

FASTEN AS REQUIRED

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

MIN 16 GA. GALVANIZED

BASE ANGLE SET IN BED OF

SEALANT (NOT BY KINGSPAN)

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

200 / 300 SERIES PANELS

STACK JOINT

STACK TRIM

HORIZONTAL SUPPORT

(NOT BY KINGSPAN)

CONTINUOUS 3" X 3" ANGLE

(GAUGE TO MATCH GIRT)

(NOT BY KINGSPAN)

POP RIVETS

8" O.C.

STACK FLASHING

CONTINUOUS BUTYL

SEALANT BELOW BASE

FLASHING

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO VERTICAL

PANEL JOINT

FASTEN AS REQUIRED

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

MIN 16 GA. GALVANIZED

BASE ANGLE SET IN BED OF

SEALANT (NOT BY KINGSPAN)

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

(2)-

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

200 / 300 SERIES PANELS

STACK JOINT

ALTERNATE

CONTINUOUS CLEAT

MEMBRANE,PARAPET

BLOCKING AND ACCESSORIES

(NOT BY KINGSPAN)

MEMBRANE ROOF &

PARAPET BACKER

(NOT BY KINGSPAN)

FASTENER TO PARAPET

BACKER (NOT BY KINGSPAN)

PARAPET CAP

1

4

" - "LOW PROFILE"

FASTENER @ 8" O.C.

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO FACE OF PANEL

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

(2) -

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

200 / 300 SERIES PANELS

PARAPET

WITH FLUSH TRIM

POP RIVETS

8" O.C.

PARAPET BACKER

(NOT BY KINGSPAN)

FASTENER TO PARAPET

BACKER

(NOT BY KINGSPAN)

PARAPET CAP

WRAP MEMBRANE,PARAPET

BLOCKING AND ACCESSORIES

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT AT PANEL JOINT

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

(2) -

1

4

" HEX HEAD

FASTENERS PER PANEL CLIP

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO FACE OF PANEL

200 / 300 SERIES PANELS

PARAPET

WITH PROFILED TRIM

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO VERTICAL JOINT

(2)

1

4

" - 14 HEX

HEAD FASTENERS

PER CLIP

BASE TRIM W/ POP RIVETS

@ 8" O.C.

MEMBRANE ROOF AND

ACCESSORIES

(NOT BY KINGSPAN

FLAT STOCK MATERIAL

(FIELD BREAK BY OTHERS)

BASE FLASHING

BASE FLASHING

14 GA. GALVANIZED

2-HOLE HIDDEN CLIP

(1 PER PANEL, PER GIRT)

SET CLIP IN BUTYL

SEALANT

200 / 300 SERIES PANELS

WALL TO ROOF

CONTINUOUS BUTYL

SEALANT W/

MARRIAGE BEAD TO

VERTICAL JOINT

(2)

1

4

" - 14 HEX HEAD

FASTENERS PER

CLIP

14 GA. HIDDEN FASTENER

CLIP

(1 PER PANEL, PER GIRT)

BASE TRIM W/ POP RIVETS

MEMBRANE ROOF,

FRAMING AND

ACCESSORIES

(NOT BY KINGSPAN)

BASE FLASHING

(2)

1

4

" - 14 HEX HEAD

FASTENERS PER

CLIP

CONTINUOUS BUTYL

SEALANT IN INTERIOR

JOINT

14 GA. HIDDEN FASTENER

CLIP

(1 PER PANEL, PER GIRT)

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO EXTERIOR

VERTICAL JOINT

MIN

6

"

CONTINUOUS BUTYL

SEALANT IN INTERIOR

JOINT

MEMBRANE

(NOT BY KINGSPAN)

SUPPORT

(NOT BY KINGSPAN)

SUPPORT

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

CONTINUOUS WALL TO

ROOF/ CANOPY

FASTENER AS REQUIRED

SEALANT (NOT BY KINGSPAN)

2PC. FLASHING AS REQUIRED

(FIELD FABRICATED FROM

FLATSTOCK)

EXPANDABLE INSULATION

(NOT BY KINGSPAN)

SEALANT (NOT BY KINGSPAN)

SEALANT

(NOT BY KINGSPAN)

2 PC. FLASHING AS REQUIRED

FASTENER AS REQUIRED

SEALANT (NOT BY KINGSPAN)

FASTENER AS REQUIRED

FASTENER AS REQUIRED

NOTE: FLASHING AT PIPE PENETRATIONS

TO BE FIELD FABRICATED FROM FLATSTOCK

SHEETS AS NECESSARY. QUANTITY OF

FLATSTOCK REQUIRED SHALL BE PROVIDED

(NOT BY KINGSPAN)

NOTE:

DO NOT ALIGN PENETRATIONS

AT PANEL JOINT LOCATIONS.

EXPANDABLE INSULATION

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

PIPE PENETRATION

SECTION

INSULATED PANEL

SILICONE SEALANT

AT TOP OF FLASHING

(NOT BY KINGSPAN)

POP RIVETS

(QUANTITY REQUIRED SHALL

BE DETERMINED BY INSTALLER)

SILICONE SEALANT AT

PERIMETER OF PIPE

(NOT BY KINGSPAN)

TWO PIECE FLASHING

WITH

1

2

" HEM. BED

SEAL TO PANEL WITH

BUTYL SEALANT (BLIND)

COPE FLASHING (FIELD

FABRICATED FROM

FLATSTOCK)

NOTE:

THIS DETAIL ASSUMES

PENETRATION OCCURS

AFTER PANEL IS INSTALLED

PIPE PENETRATION

(NOT BY KINGSPAN)

NOTE:

DO NOT ALIGN PENETRATIONS

AT PANEL JOINT LOCATIONS.

SILICONE SEALANT

BETWEEN FLASHINGS

(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONS

TO BE FIELD FABRICATED FROM FLATSTOCK

SHEETS AS NECESSARY. QUANTITY OF

FLATSTOCK REQUIRED SHALL BE DETERMINED BY INSTALLER

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

PIPE PENETRATION

ISOMETRIC

INSULATED PANEL

NOTE: THIS DETAIL ASSUMES

PENETRATION OCCURS

AFTER PANEL IS INSTALLED

SILICONE SEALANT

AT TOP OF FLASHING

(NOT BY KINGSPAN)

POP RIVETS

(QUANTITY REQUIRED SHALL

BE DETERMINED BY INSTALLER)

TWO PIECE FLASHING

WITH

1

2

" HEM. BED

SEAL TO PANEL WITH

BUTYL SEALANT (BLIND)

COPE FLASHING

(NOT BY KINGSPAN)

SILICONE SEALANT

BETWEEN FLASHINGS

(NOT BY KINGSPAN)

KNIFE PENETRATION

(NOT BY KINGSPAN)

SILICONE SEALANT AT

PERIMETER OF KNIFE

(NOT BY KINGSPAN)

INSULATED PANEL

POP RIVETS

SILICONE SEALANT

AT TOP OF FLASHING

(NOT BY KINGSPAN)

KNIFE PENETRATION

SILICONE SEALANT AT

PERIMETER OF KNIFE

(NOT BY KINGSPAN)

FILL VOID WITH F.I.P

INSULATION

(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONS

TO BE FIELD FABRICATED FROM FLATSTOCK

SHEETS AS NECESSARY. QUANTITY OF

FLATSTOCK REQUIRED SHALL BE DETERMINED

BY INSTALLER

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

KNIFE PENETRATION

DETAIL

INSULATED PANEL

SILICONE SEALANT

AT TOP OF FLASHING

(NOT BY KINGSPAN)

SILICONE SEALANT AT

PERIMETER OF KNIFE

(NOT BY KINGSPAN)

TWO PIECE FLASHING

WITH

1

2

" HEM. BED

SEAL TO PANEL WITH

BUTYL SEALANT (BLIND)

COPE FLASHING

(NOT BY KINGSPAN)

SILICONE SEALANT

BETWEEN FLASHINGS

(NOT BY KINGSPAN)

NOTE: THIS DETAIL ASSUMES

PENETRATION OCCURS

AFTER PANEL IS INSTALLED

KNIFE PENETRATION

(NOT BY KINGSPAN)

POP RIVETS

(QUANTITY REQUIRED

SHALL BE DETERMINED

BY INSTALLER)

NOTE: FLASHING AT PENETRATIONS

TO BE FIELD FABRICATED FROM FLATSTOCK

SHEETS AS NECESSARY. QUANTITY OF

FLATSTOCK REQUIRED SHALL BE DETERMINED

BY INSTALLER

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

KNIFE PENETRATION

ISOMETRIC

NOTE: THIS DETAIL ASSUMES

PENETRATION OCCURS

AFTER PANEL IS INSTALLED

INSULATED PANEL

POP RIVETS

SILICONE SEALANT

AT TOP OF FLASHING

(NOT BY KINGSPAN)

BEAM PENETRATION

SILICONE SEALANT AT

PERIMETER OF BEAM

(NOT BY KINGSPAN)

FILL VOID WITH F.I.P

INSULATION

(NOT BY KINGSPAN)

INSULATED PANEL

SILICONE SEALANT

AT TOP OF FLASHING

(NOT BY KINGSPAN)

TWO PIECE FLASHING

WITH

1

2

" HEM. BED

SEAL TO PANEL WITH

BUTYL SEALANT (BLIND)

COPE FLASHING

(NOT BY KINGSPAN)

BEAM PENETRATION

(NOT BY KINGSPAN)

SILICONE SEALANT AT

PERIMETER OF BEAM

(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONS

TO BE FIELD FABRICATED FROM FLATSTOCK

SHEETS AS NECESSARY. QUANTITY OF

FLATSTOCK REQUIRED SHALL BE DETERMINED

BY INSTALLER

(NOT BY KINGSPAN)

POP RIVETS

(QUANTITY REQUIRED

SHALL BE DETERMINED

BY INSTALLER)

SILICONE SEALANT

BETWEEN FLASHINGS

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

BEAM PENETRATION

DETAIL

NOTE: THIS DETAIL ASSUMES

PENETRATION OCCURS

AFTER PANEL IS INSTALLED

INSULATED PANEL

SILICONE SEALANT

AT TOP OF FLASHING

(NOT BY KINGSPAN)

SILICONE SEALANT AT

PERIMETER OF BEAM

(NOT BY KINGSPAN)

TWO PIECE FLASHING

WITH

1

2

" HEM. BED

SEAL TO PANEL WITH

BUTYL SEALANT (BLIND)

COPE FLASHING

(NOT BY KINGSPAN)

SILICONE SEALANT

BETWEEN FLASHINGS

(NOT BY KINGSPAN)

BEAM PENETRATION

(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONS

TO BE FIELD FABRICATED FROM FLATSTOCK

SHEETS AS NECESSARY. QUANTITY OF

FLATSTOCK REQUIRED SHALL BE DETERMINED

BY INSTALLER

(NOT BY KINGSPAN)

POP RIVETS

(QUANTITY REQUIRED

SHALL BE DETERMINED

BY INSTALLER)

200 / 300 SERIES PANELS

BEAM PENETRATION

ISOMETRIC

M

I

N

.

3

"

T

R

I

M

L

A

P

M

I

N

.

3

"

T

R

I

M

L

A

P

(2) BEADS

BUTYL SEALANT

200 / 300 SERIES PANELS

TRIM END LAP

M

I

N

.

3

"

T

R

I

M

L

A

P

M

I

N

.

3

"

T

R

I

M

L

A

P

(2) BEADS

BUTYL SEALANT

FIELD NOTCH HEM(S)

AS REQUIRED

(NOT BY KINGSPAN)

200 / 300 SERIES PANELS

TRIM LAP WITH HEM

(2) BEADS

BUTYL SEALANT

N

O

M

.

1

4

"

G

A

P

8" LONG LAP STRIP

200 / 300 SERIES PANELS

TRIM END LAP WITH

LAP STRIP

TRIM INSTALLATION SEQUENCE:

1 DRIP FLASHING HEAD TRIM WITH TABS DOWN

2 SILL TRIM WITH TABS UP

3 JAMB TRIM

4 CAP TRIM AT HEAD

5 EXTERIOR SEALANTS AS REQUIRED

C

A

P

T

R

I

M

A

T

H

E

A

D

D

R

I

P

F

L

A

S

H

I

N

G

A

T

H

E

A

D

CA

P T

RIM

A

T JA

MB

D

R

I

P

F

L

A

S

H

I

N

G

A

T

H

E

A

D

FIELD CUT/NOTCH

CAP TRIM AT

CORNERS TO

ALLOW FOR LAP

(NOT BY KINGSPAN)

FIELD CUT/NOTCH

CAP TRIM AT

CORNERS TO

ALLOW FOR LAP

(NOT BY KINGSPAN)

S

I

L

L

T

R

I

M

OVERLAP TRIMS,

POP RIVET AS

NECESSARY (NOT BY

KINGSPAN)

OVERLAP TRIMS,

POP RIVET AND SEAL

AS NECESSARY (NOT

BY KINGSPAN)

JAMB TRIM

3

DRIP FLASHING WITH

TABS BENT DOWN

1

SILL TRIM WITH TAB

BENT UP

2

CAP TRIM AT HEAD4

SEALANT END DAM

ACROSS DRIP

FLASHING (TYPICAL

BOTH ENDS)

EXPOSED SEALANT

(TYPICAL BOTH

ENDS, NOT BY

KINGSPAN)

VERTICAL SEALANT MARRIAGE BEAD W/

END DAM SEALANT (TYPICAL BOTH ENDS)

5

ISOMETRIC VIEW

SEE (KIP 701) EXPLODED VIEW FOR CLARITY

EXPOSED SEALANT ACROSS SILL TRIM

( NOT BY KINGSPAN)

5

200 / 300 SERIES PANELS

TRIM LAP AT FRAMED

OPENING - ISOMETRIC

EX

TE

RIO

R C

AP

TR

IM

A

T JA

MB

MIN. 3" TAB FOLD OVER

INTERIOR JAMB TRIM,

APPLY SEALANT IN

BETWEEN (TYPICAL

BOTH ENDS)

S

I

L

L

T

R

I

M

MIN. 3" TAB FOLD OVER

INTERIOR JAMB TRIM, APPLY

SEALANT IN BETWEEN

(TYPICAL BOTH ENDS)

1

TRIM INSTALLATION SEQUENCE:

1 INTERIOR JAMB TRIM (NOTCH)

2 DRIP FLASHING HEAD TRIM WITH TABS BENT DOWNS

3 SILL TRIMS WITH TABS BENT UP

4 EXTERIOR JAMB TRIM

5 EXTERIOR CAP TRIM AT HEAD

EXPLODED VIEW

IN

TE

RIO

R C

AP

TR

IM

A

T JA

MB

2

3

4

4

IN

TE

RIO

R C

AP

TR

IM

A

T JA

MB

EX

TE

RIO

R C

AP

TR

IM

A

T JA

MB

1

D

R

I

P

F

L

A

S

H

I

N

G

A

T

H

E

A

D

C

A

P

T

R

I

M

A

T

H

E

A

D

5

200 / 300 SERIES PANELS

TRIM LAP AT FRAMED

OPENING - EXPLODED

VIEW