2
NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this
program will be reported to CES Records for AIA members. Certificates of Completion for non-AIA members
are available on request.
This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or
construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or
dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of
this presentation.
![Page 3: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/3.jpg)
3
Learning Learning ObjectivesObjectives
• Discuss the American National Standards for the most common tiles installed in today's market
• Identify causes of job-site problems and how to avoid them
• To understand the limitations for proper installation of large format tile
![Page 4: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/4.jpg)
With the conversion to thin-bed methods, With the conversion to thin-bed methods, installation has become a installation has become a
knowledge-based tradeknowledge-based trade
• Evaluation/remediation of substrate issues
• Engineering (load) considerations a factor
• Many products and manufacturers to address a multitude of thin-bed considerations
![Page 5: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/5.jpg)
A137.1 StandardA137.1 Standard
• More than 30 pages
• Outlines performance for:• Mosaic Tile• Quarry Tile• Glazed Wall Tile• Pressed floor tile• Porcelain tile
![Page 6: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/6.jpg)
What is A137.1?What is A137.1?Purposes:
• establishes minimum acceptance criteria for ceramic tile mfrs. (quality control)
• reference standard for buyers and specifiers
• A137.1 labeling conveys what’s in the box
![Page 7: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/7.jpg)
9 Non-Destructive Tests9 Non-Destructive Tests
• Evaluation for facial and structural defects
• Facial dimensions• Warpage • Wedging• Thickness• Coefficient of friction• Mounting (mosaics) • Color uniformity• Shade value
![Page 8: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/8.jpg)
12 Destructive Tests12 Destructive Tests• Bond strength• Breaking strength• Chemical resistance• Stain resistance• Deep abrasion• Visual abrasion resistance• Thermal Shock resistance• Crazing resistance• Moisture expansion• Thermal expansion• Resistance to freeze/thaw• Water absorption
![Page 9: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/9.jpg)
DefinitionsDefinitions
• Natural tile: tile that is not sized, nor sorted mechanically
• Calibrated tile: tile that has been sorted and boxed based on its facial dimensions
• Rectified tile: tile that has had all edges mechanically finished to achieve a more precise facial dimension
![Page 10: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/10.jpg)
TCATCA
• Both the handbook and ANSI Standards are Voluntary Standards
• There is no compliance requirement
RememberRememberthere are no tile policethere are no tile police
![Page 11: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/11.jpg)
There are also There are also Voluntary International StandardsVoluntary International Standards
• ISO (International Standards Organization)• ISO 13006-Standards for Ceramic Tile • There are 17 tests under ISO 13006 similar to and in
some cases the same as ANSI• Two areas of disagreement are Freeze/Thaw and Slip
Resistance
![Page 12: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/12.jpg)
GENERAL CURRENT CONSENSUSGENERAL CURRENT CONSENSUSGENERAL CURRENT CONSENSUSGENERAL CURRENT CONSENSUS
ANY ONE SIDE 15 INCHES and larger IS “Large Format”
![Page 13: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/13.jpg)
Standards DevelopmentStandards DevelopmentASTM C627 Test MethodASTM C627 Test MethodStandards DevelopmentStandards DevelopmentASTM C627 Test MethodASTM C627 Test Method
![Page 14: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/14.jpg)
Accessibility: Accessibility: Flatness and LippageFlatness and Lippage
Accessibility: Accessibility: Flatness and LippageFlatness and Lippage
• A flat tile installation requires a flat substrate
• Designate trade responsible when substrate does not meet flatness requirements:• 1/4˝ in 10´ and 1/16˝ in 1´• 1/8˝ in 10´ may be required for large format tile • no more than 1/32˝ difference between modular substrate
edges
• Or, specify a mortar bed or self-leveler method
![Page 15: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/15.jpg)
New language addresses New language addresses grout joint sizegrout joint size
• For requirements on workmanship, cutting, fitting and grout joint size refer to ANSI A108.02 section 4.3.8 To accommodate the range in facial dimensions of the tile
supplied for a specific project, the actual grout joint size may, of necessity, vary from the grout joint size specified. The actual grout joint size shall be at least 3 times the actual range of facial dimensions of the tile supplied. Example: for tile having a total variation of 1/16” in facial dimensions, a minimum 3/16” grout joint shall be used
1/16” minimum grout joint size
![Page 16: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/16.jpg)
LIPPAGELIPPAGE
![Page 17: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/17.jpg)
LIPPAGELIPPAGE
![Page 18: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/18.jpg)
Minimizing Lippage Minimizing Lippage
• Specify wider joints for more gradual changes
• Off-set patterns can sometimes result in more lippage
• Beveled/cushion-edge tiles can minimize effects of lippage
![Page 19: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/19.jpg)
Medium bed thinset?Medium bed thinset?
• No Standards• Manufacturers vary on maximum thickness• ½ inch to ¾ inch• Not intended to be used for true up• Designed to hold more weight
![Page 20: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/20.jpg)
IMPORTANT EDITORIAL ADDITIONS IMPORTANT EDITORIAL ADDITIONS SUBSURFACE TOLERANCESUBSURFACE TOLERANCE
• Thin-set is not intended to be used in truing or leveling the work of others
• The subsurface typically should not vary by more than 1/16" over 1’-0", nor more than 1/32˝ between adjoining edges (where applicable: e.g. sheets of plywood or between adjacent concrete masonry units).
![Page 21: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/21.jpg)
MOVEMENT MOVEMENT ACCOMMODATIONACCOMMODATION
![Page 22: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/22.jpg)
Thermal ExpansionThermal Expansion
• Growth due to raised temperature, such as direct sunlight or steam room applications
• Growth varies by type of tile
• Growth is cyclical – may occur several times in a single day
Moisture Moisture ExpansionExpansion
• Growth due to moisture exposure
• Irreversible and long-term growth
• Exteriors and other areas of high moisture are critical
![Page 23: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/23.jpg)
Both can cause “Tenting”Both can cause “Tenting”
![Page 24: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/24.jpg)
……thanks to thanks to contractor contractor
associationsassociations
![Page 25: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/25.jpg)
Specifier needs to Specifier needs to SPECIFY which SPECIFY which method applies in method applies in the contractthe contract
– – full or partial full or partial coverage!coverage!
![Page 26: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/26.jpg)
Thin-set coverage requirement is Thin-set coverage requirement is 80% interior / 95% exterior and wet areas80% interior / 95% exterior and wet areas
![Page 27: 2 NTCA is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will.](https://reader035.fdocuments.in/reader035/viewer/2022070306/551789855503460e6e8b570a/html5/thumbnails/27.jpg)
QUESTIONS?QUESTIONS?