2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request....

55
2 EU Declaration of Conformity (EMC) Type of equipment: POS-Watch PSE Model Name: POS-Watch PSE Variant Model Name: PSE-1648C PSE-1624C,PSE-1612C,PSE-0824H PSE-0824C, PSE-0812C,PSE-0412D,PSE-0412H PSE-0412C, KXR3516P, KXR3508P, KXR3504P Applicant: POSDATA CO., LTD Address: 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea Manufacturer: D.H ELECTRONICS CO.,LTD. Address: 501-13, Munhak-ri, Jeongnam-myun, Hwaseong-city, Kyeonggi-do 445-961,Korea We hereby declare, that all major safety requirements, concerning to CE Mark Directive(93/68/EEC) Electromagnetic Compatibility Directives (2004/108/EC,92/31/EEC) are fulfilled, as laid out in the guideline set down by the member states of the EEC Commission. This declaration is valid for all samples that are part of this declaration, which are manufactured according to the production charts appendix. The standards relevant for the evaluation of electrical safety requirements are as follows : EMC : EN 55022:1998+A1+A2:2003, EN 55024:1998+A1+A2:2003 EN 61000-3-2:2005, EN 61000-3-3:1995+A1:2001 1. Certificate of conformity / Test report issued by : EMC : EMC Compliance Laboratory Certificate No. : EMC-CE-1524 2. Technical documentation kept at : POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea (place and date of issue) (name and signature of authorized person)

Transcript of 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request....

Page 1: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

2

EU Declaration of Conformity (EMC) Type of equipment: POS-Watch PSE

Model Name: POS-Watch PSE

Variant Model Name: PSE-1648C PSE-1624C,PSE-1612C,PSE-0824H PSE-0824C, PSE-0812C,PSE-0412D,PSE-0412H PSE-0412C, KXR3516P, KXR3508P, KXR3504P

Applicant: POSDATA CO., LTD

Address: 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea Manufacturer: D.H ELECTRONICS CO.,LTD.

Address: 501-13, Munhak-ri, Jeongnam-myun, Hwaseong-city, Kyeonggi-do 445-961,Korea

We hereby declare, that all major safety requirements, concerning to CE Mark Directive(93/68/EEC)

Electromagnetic Compatibility Directives (2004/108/EC,92/31/EEC)

are fulfilled, as laid out in the guideline set down by the member states of the EEC Commission.

This declaration is valid for all samples that are part of this declaration, which are manufactured

according to the production charts appendix.

The standards relevant for the evaluation of electrical safety requirements are as follows :

EMC : EN 55022:1998+A1+A2:2003, EN 55024:1998+A1+A2:2003 EN 61000-3-2:2005, EN 61000-3-3:1995+A1:2001

1. Certificate of conformity / Test report issued by :

EMC : EMC Compliance Laboratory Certificate No. : EMC-CE-1524

2. Technical documentation kept at :

POSDATA CO., LTD which will be made available upon request.

POSDATA CO., LTD

276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea (place and date of issue)

(name and signature of authorized person)

Page 2: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 1 of 54

EMC TEST REPORT

Test report no.: EMC-CE-1524

Type of equipment: POS-Watch PSE

Model Name: POS-Watch PSE

Variant Model Name: PSE-1648C PSE-1624C,PSE-1612C PSE-0824H, PSE-0824C, PSE-0812C PSE-0412D,PSE-0412H, PSE-0412C KXR3516P, KXR3508P, KXR3504P

Applicant: POSDATA CO., LTD

Manufacturer: D.H ELECTRONICS CO.,LTD.

Test standards: EN 55022:1998+A1+A2:2003 Class A EN 50130-4:1995+A1+A2:2003

EN 61000-3-2:2005 EN 61000-3-3:1995+A1:2001

Testing Laboratory: EMC Compliance Ltd.

Test result: Complied This product complies with the requirements of the EMC Directive 2004/108/EC. The results in this report apply only to the sample tested. This test report shall not be reproduced except in full, without the written approval of EMC compliance Laboratory.

Date of test: 2005. 09. 04~05

Issued date: 2008. 11. 05

Tested by: Reviewed by:

BAEK, JEONG-SOO CHUNG, MIN-SEOK

Page 3: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 2 of 54

Contents

1. Client information ................................................................................... 3

2. Laboratory information ............................................................................ 4

3. Test system configuration......................................................................... 5

3.1 Operation environment............................................................... 5

3.2 Measurement Uncertainty ........................................................... 5

3.3 Sample calculation..................................................................... 6

4. Description of E.U.T. ................................................................................ 7

4.1 Product description .................................................................... 7

4.2 Peripherals ............................................................................... 7

4.3 Operating conditions.................................................................... 8

4.4 Used cables .............................................................................. 8

4.5 EUT test configuration ................................................................ 9

5.1 Modification to the E.U.T. .......................................................... 10

5.2 Standards & results ................................................................. 10

6. Test results .......................................................................................... 11

6.1 Conducted Emission................................................................. 11

6.2 Radiated emission ................................................................... 15

6.3 Electrostatic Discharge ............................................................. 17

6.4 Radio Frequency Electromagnetic Fields ...................................... 20

6.5 Electric Fast Transient/BURST .................................................... 22

6.6 Surge .................................................................................... 24

6.7 Conducted Immunity................................................................ 26

6.8 Dips and Interruptions ............................................................. 28

6.10 Harmonics ............................................................................ 30

6.11 Flicker.................................................................................. 34

7. Test photographs .................................................................................. 36

8. E.U.T. photographs................................................................................ 43

Page 4: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 3 of 54

1. Client information Applicant: POSDATA CO., LTD Address: 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea Telephone Number : + 82-31-799-2864 Facsimile Number : + 82-31-799-2668 Manufacturer: D.H ELECTRONICS CO.,LTD. Address: 501-13, Munhak-ri, Jeongnam-myun, Hwaseong-city, Kyeonggi-do 445-961,Korea

Page 5: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 4 of 54

2. Laboratory information

Address

EMC compliance Ltd.

82-1 Jeil-ri, Yangji-myun, Churingu, Yongin-city, Kyunggi-do 449-825, Korea

Telephone Number : 82 31 336 9919

Facsimile Number : 82 31 336 4767

CBTL Testing Laboratory

FCC Filing No.: 793334

FCC CAB.: KR0040

VCCI Registration No. : C-1713, R-1606, T-258

KOLAS NO.: 231

SITE MAP

EMC compliance

Yongin city

Page 6: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 5 of 54

3. Test system configuration

3.1 Operation environment

Temperature Humidity Pressure

OATS : 24 °C 57 % -

Shielded room : 22 °C 50 % - Immunity area : 22 °C 48 % 994 hPa

Test site

These testing items were performed following locations;

OATS (10m) : Radiated Emission

Shielded Room : Conducted Emission

Immunity area : ESD ,RS, EFT/ Burst, SURGE, CS, Magnetic,

Dip/Interruption, Harmonic, Flicker

3.2 Measurement Uncertainty

All measurements involve certain levels of uncertainties, especially in field

of EMC.

The factors contributing to uncertainties are test receiver, cable loss,

antenna factor calibration, Antenna directivity, antenna factor variation with

height, antenna phase center variation, antenna frequency interpolation,

measurement distance variation, site imperfection, mismatch, and system

repeatability.

Based on NIS 80, 81, the measurement uncertainty level with a 95%

confidence level was applied.

Page 7: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 6 of 54

3.3 Sample calculation

Conducted Emission

The field strength is calculated by adding the LISN factor, cable loss from

the measured reading.

The sample calculation is as follows :

FS = MR + LF + CL

MR = Meter Reading

LF = LISN Factor

CL = Cable Loss

If MR is 30dB, LISN Factor 1dB, CL 1dB

The result (MR) is

30 + 1 + 1 = 32dBuV

Page 8: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 7 of 54

4. Description of E.U.T.

4.1 Product description

Applicant: POSDATA CO., LTD

Address of Applicant: 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

Manufacturer: D.H ELECTRONICS CO.,LTD.

Address of Manufacturer: 501-13, Munhak-ri, Jeongnam-myun, Hwaseong-city, Kyeonggi-do 445-961,Korea

Type of equipment: POS-Watch PSE Basic Model: POS-Watch PSE

Variant Model: PSE-1648C PSE-1624C, PSE-1612C,PSE-0824H PSE-0824C, PSE-0812C,PSE-0412D,PSE-0412H PSE-0412C, KXR3516P, KXR3508P, KXR3504P

The differnece between basic model and variant model:

Real board,BNC and RCA Buyer model name

Serial number: -

Power Rating: 230Vac,50Hz

4.2 Peripherals

Description Model / Part # Serial number Manufacturer

Monitor RB19NS N434H4JX31771F SAMSUNG

CCD camera - KCC-41 KOCOM

USB keyboard SK-8115 - DELL

USB mouse1 M-UV69a HCA51201595 LG

USB mouse2 M-UV69a HCA51201503 LG

Page 9: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 8 of 54

4.3 Operating conditions

- REC mode

- Video Capture mode.

- Ping Test was done by the PC system.

4.4 Used cables

Start END Cable Spec.

Name I/O Port Name I/O Port Length Shield

RS-485/RS-422 port OPEN RS-485/RS-422 port 3.0 Non-shield

Controller in/out port OPEN Controller in/out port 1.0 Non-shield

Play port 75 OHM termination Play port 1.5 Shield

Live port OPEN Live port 1.5 Shield

Audio L-P 1~4 port OPEN Audio L-P 1~4 port 2.0 Non-shield

Video in 1 port CCD camera Video in 1 port 3.0 Shield

Video in 2~16 port 75 OHM termination Video in 2~16 port 1.5 Shield

Video out 1 port Monitor Video out 1 port 3.0 Shield

Video out 2~16 port 75 OHM termination

Video out 2~16 port 1.5 Shield

Spot port 75 OHM termination Spot port 1.5 Shield

TV out port 75 OHM termination TV out port 3.0 Shield

D-SUB port Monitor D-SUB port 1.8 Shield

S-video port Monitor S-video port 1.5 Shield

Ethernet port - Ethernet port 3.0 Non-shield

EUT

Console port OPEN Console port 2.0 Non-shield

Page 10: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 9 of 54

4.5 EUT test configuration

EUT

console

USBkeyboard

USBmouse1

USBmouse2

playlive

controller in/out

AudioL-R 1~4

RS-485/RS-422

scsi

TV out

A

Amonitor

cameravideo in 1

video in 2~16SUB

video out 1

S-video out

spotvideo out 2~16video in 2~16

Page 11: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 10 of 54

5. Summary of test results

5.1 Modification to the E.U.T. None

5.2 Standards & results

The following standards have been applied:

EN 55022:1998+A1+A2:2003

Information technology equipment – Radio disturbance characteristics -

Limits and methods of measurement

Test items Result Conducted emission Pass Radiated emission Pass

EN 50130-4:1995+A1+A2:2003

Alarm systems – part 4: Electromagnetic compatibility – Product Family

standard: Immunity requirements for components of fire, intruder

and social alarm systems

Test items Test methods Result Electrostatic discharge EN 61000-4-2:1995+A1+A2:2001 Pass Electromagnetic field EN 61000-4-3:1995+A1+A2:2001 Pass Electric fast transients EN 61000-4-4:1995+A1:2001 Pass Surge EN 61000-4-5:1995+A1:2001 Pass Conducted Immunity EN 61000-4-6:1995+A1:2001 Pass Magnetic field immunity EN 61000-4-8:1993 Pass Voltage dip/interruption EN 61000-4-11:1994+A1:2001 Pass

EN61000-3-2:2000 +A2:2005

Electromagnetic compatibility (EMC) – Part 3-2: Limits for harmonic-current

emissions (equipment input current up to including 16A per phase)

Test items Test methods Result

Harmonics EN 61000-3-2:2000+A2:2005 Pass

EN 61000-3-3:1995+A1 : 2001 Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16A per phase and not subject to conditional connection Test items Test methods Result

Flicker EN 61000-3-3: 1995/A1 : 2001 Pass

Page 12: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 11 of 54

6. Test results

6.1 Conducted Emission

6.1.1 Measurement procedure

Mains

The measurements were performed in a shielded room.

EUT was placed on a non-metallic table height of 0.8 m above the reference

ground plane.

The rear of table was located 0.4 m to the vertical conducted plane.

Each EUT power lead, except ground (safety) lead, was individually

connected through a LISN to input power source.

Both lines of power cord, hot and neutral, were measured.

6.1.2 Used equipments

Equipment Model Serial No. Makers Next Cal. Date Used

Test receiver ESHS30 844827/011 R&S 08.08.07

LISN ESH3-Z5 846128/024 R&S 08.07.30

LISN L3-32 0120J20305 PMM -

6.1.3 Measurement uncertainty

Conducted emission measurement : (k=2, 95%)

9kHz-150 kHz : ±3.281

150kHz-300 MHz : ±2.977

Page 13: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 12 of 54

6.1.4 Test data

Correction Quasi-peak Average Frequency

Factor Limit Reading Result Limit Reading Result

[MHz] LISN Cable

Line

[dBuV] [dBuV] [dBuV] [dBuV] [dBuV] [dBuV]

0.297 0.25 0.4 H 79.00 50.56 51.21 66.00 37.25 37.90

0.300 0.22 0.4 N 79.00 50.18 50.80 66.00 37.27 37.89

0.459 0.19 0.3 N 79.00 51.97 52.46 66.00 35.60 36.09

0.465 0.26 0.3 H 79.00 51.46 52.02 66.00 35.45 36.01

0.594 0.16 0.3 N 73.00 45.36 45.82 60.00 31.86 32.32

0.792 0.25 0.2 H 73.00 43.84 44.29 60.00 23.30 23.75

0.891 0.17 0.2 N 73.00 43.70 44.07 60.00 32.12 32.49

1.188 0.18 0.1 N 73.00 35.79 36.07 60.00 22.16 22.44

1.191 0.27 0.1 H 73.00 35.69 36.06 60.00 22.94 23.31

12.750 0.51 0.2 N 73.00 37.71 38.42 60.00 33.19 33.90

21.220 0.83 0.2 H 73.00 39.81 40.84 60.00 27.71 28.74

22.200 0.68 0.6 N 73.00 41.03 42.31 60.00 27.52 28.80

• Note. QP = Quasi-Peak, AV= Average

• Loss = LISN Loss + Cable Loss

• Measurement time : 1 s

Page 14: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 13 of 54

Page 15: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 14 of 54

6.1.5. Result

Minimum limit margin is 26.10 dB at 12.750 MHz.

Page 16: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 15 of 54

6.2 Radiated emission

6.2.1 Measurement procedure

A pretest was performed at 3m distance in a semi-anechoic chamber for

searching correct frequency. The final test was done at a 10m open area

test site with a quasi-peak detector. EUT was placed on a non-metallic table

height of 0.1m above the reference ground plane. Cables were folded back

and forth forming a bundle 0.3m to 0.4m long and were hanged at a 0.4m

height to the ground plane. Cables connected to EUT were fixed to cause

maximum emission. Test was made with the antenna positioned in both the

horizontal and vertical planes of polarization. The measurement antenna

was varied in height above the conducting ground plane to obtain the

maximum signal strength.

6.2.2 Used equipments

Equipment Model no. Serial no. Makers Next cal. date Used

Test Receiver ESCI 100001 R&S 07.10.31 TRILOG SUPER

BROADBAND ANT VULB 9160 3228 Schwarzbeck Mess-Electronik 08.02.12

Antenna Mast A109 N/A DEAIL - Turn Table TS14 N/A DEAIL - 10m OATS - - EMC Compliance -

6.2.3 Measurement uncertainty

Radiated Emission measurement : (k=2, 95%)

30-300 MHz ; 3 m: ±3.721 [dB], 10 m: +3.706, -3.707 [dB]

300-1000 MHz ; 3 m: ±3.818 [dB], 10 m: ±3.802 [dB]

Page 17: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 16 of 54

6.2.4 Test data

Correction Frequency Reading Pol. Height angle

Factor Limits Result Margin

[MHz] [dBuV/m] [m] Antenna Cable [dBuV/m] [dBuV/m] [dB]

160.14 13.1 H 4.0 228 12.83 2.52 40.0 28.45 11.55

168.00 16.2 H 4.0 140 12.25 2.58 40.0 31.03 8.97

199.26 17.5 H 4.0 164 9.62 2.81 40.0 29.93 10.07

312.00 17.2 V 1.0 307 13.31 3.48 47.0 33.99 13.01

320.28 22.0 V 1.0 198 13.54 3.55 47.0 39.08 7.92

433.33 16.7 H 2.6 187 16.20 4.18 47.0 37.07 9.93

500.00 16.7 H 1.6 332 17.46 4.52 47.0 38.68 8.32

599.99 14.3 H 1.6 138 19.68 4.90 47.0 38.88 8.12

648.00 13.1 V 1.0 335 20.19 5.13 47.0 38.42 8.58

720.63 5.6 V 1.9 23 21.30 5.59 47.0 32.50 14.50

833.38 8.1 V 2.1 298 22.73 5.95 47.0 36.78 10.22

* 10 m OATS

* Note : Reading = Test Receiver meter,

P= Polarization POL H = Horizontal, POL V = Vertical

* Result = Field Strength (Antenna factor + Cable factor + Reading)

6.2.5. Result

Minimum limit margin is 8.12 dB at 599.99 MHz.

Page 18: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 17 of 54

6.3 Electrostatic Discharge

6.3.1 Measurement procedure

A ground reference plane was located on the floor, and connected to earth

via a low impedance connection.

The return cable of the ESD generator was connected to the reference plane.

In case of floor standing equipment, EUT was placed on the reference plane

on 0.1 m of insulating Support.

In case of table top equipment, EUT was placed on a wooden table 0.8m

above the reference grounded floor.

A horizontal coupling plane(HCP) was placed on the table, and Connected to the reference plane via a 470 resistor located in each end

(0.5mm insulating support between EUT and HCP).

In both cases a vertical coupling plane(VCP) OF 0.5 X 0.5m was located

10cm from the EUT’s sides.

The VCP was connected to the reference plane in the same matter as the

HCP.

6.3.2 Used equipments

Equipment Model No. Serial No. Makers Next Cal. Date Used

ESD Tester PESD 1600 H011 309 HAEFELY 2008.05.03

HCP - - - -

VCP - - - -

Page 19: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 18 of 54

6.3.3 Test Data

Test Specification : EN61000-4-2

Kind of Discharges Contact Discharge

Air Discharge

HCP / VCP

Discharge Voltages Contact Discharge : ± 2, 4, 6kV

Air Discharge : ± 2, 4, 8kV

Discharge Impedance 330 Ω/150 2KΩ/330

Number Of Discharge Number of discharges per point, for each voltage and polarity

: 10 (Interval between discharges: ≥ 1s)

Test point ( Please refer to attached photograph. )

Contact Discharge : Case, Rear brocket, Screw, BNC port, Ethernet port,

Audio port, SCSI port, FAN, Console port, D-SUB port

Rear USB port

Air Discharge : RS-485/RS-422, Front button, Front USB port

Test Results Complied Not complied

Comment :

- There was no change of operation status during above testing.

Page 20: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 19 of 54

Electrostatic Discharge (Test Point)

Air discharge

Contact discharge

Page 21: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 20 of 54

6.4 Radio Frequency Electromagnetic Fields

6.4.1 Measurement procedure

The test was performed at 3m full anechoic chamber.

For floor standing equipment, the EUT was standing on the floor.

For tabletop equipment, the EUT was located on a wooden table 0.8m above

the floor.

The EUT was tested all sides, horizontal and vertical polarization.

The field uniformity was calibrated for 1V/m, 3V/m, 10V/m.

6.4.2 Used equipments

Equipment Model no. Serial no. Makers Next Cal. date Used

Power meter PM2002 302852 AR 08.05.03 Field monitor SI-300 - TDK - Power sensor (with adapter) PH2000 303224 AR 08.05.03

Power sensor (with adapter) PH2000 303222 AR 08.05.03

Directional coupler DC6180 303976 AR 08.05.03 Amplifier 150W1000M2 303843 AR 08.05.03 Amplifier 60S1G3M2 320444 AR 08.04.21

Signal generator E4421B GB40052295 AGILENT 07.10.10 BiconiLog Ant. LPDA-0803 130269 ETS 08.03.17

Directional Coupler DC7144M1 320279 AR 08.01.18

6.4.3 Measurement uncertainty

Radio Frequency Electromagnetic Fields : ± 1.0556 [dB](k=2, 95%)

Page 22: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 21 of 54

6.4.4 Test Data

Test Specification : EN 61000-4-3

Frequency Range 80MHz – 2GHz 900 MHz ± 5MHz 26MHz - 500MHz

Test level 1V/m 3V/m 10V/m

Modulation AM : 1kHz, 80%

PM : 1Hz (0.5s ON: 0.5 s OFF)

Frequency step log 1% step log 3% step log 5% step

Dwell Time 3 s 2 s 1 s

Test point Front

Rear

Left

Right

Test Results Complied Not complied

Comment :

-There was no change of operation status during above testing.

(1V/m & 3V/m)

-During the test, EUT appeared dot & flickering. After this test, EUT was

operated normally. (10V/m)

Page 23: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 22 of 54

6.5 Electric Fast Transient/BURST

6.5.1 Measurement procedure

A ground reference plane was located on the floor.

EFT generator was connected to reference ground plane via low impedance

connection.

For floor standing equipment, EUT was placed on a 0.1 m wooden table.

For tabletop equipment, EUT was placed on a wooden table(0.8m)

above the reference plane.

6.5.2 Used equipments

Equipment Model No. Serial No. Makers Next Cal. date Used

EFT/B Tester UCS 500 M6 V0545100858 EM TEST 08.01.03

Capacitive coupling clamp N/A N/A EM TEST -

Page 24: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 23 of 54

6.5.3 Test Data

Test Specification : EN 61000-4-4

Coupling Power Signal Lines Telecommunication line

Test level Power : ±0.5 kV & ±1kV & ±2 kV

Signal Line : ±0.5 kV & ±1kV

Tel. line :

Test mode

- Power : L1, L2, PE, L1+L2, L1+PE, L2+PE, L1+L2+PE

- Signal line : Video in, Video out, TV out, RS-485/RS-422

Burst frequency : 5 kHz, 5/50 ns

Coupling Time : > 60 s

Test Results Complied Not complied

Comment :

-There was no change of operation status during above testing. (0.5KV)

-During the test, EUT appeared dot & flickering. After this test, EUT was

normally. (1KV & 2KV)

Page 25: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 24 of 54

6.6 Surge

6.6.1 Measurement procedure

A ground reference plane was located on the floor.

SURGE generator was connected to reference ground plane via low

impedance connection.

For floor standing equipment, EUT was placed on a 0.1 m wooden table.

For tabletop equipment, EUT was placed on a wooden table(0.8m) above

the reference plane.

6.7.2 Used equipments

Equipment Model No. Serial No. Makers Next Cal. date Used

Surge Generator UCS 500 M6 V0545100858 EM TEST 08.01.03

CDN CNV 508 S2 0402-01 EM TEST -

Page 26: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 25 of 54

6.6.3 Test Data

Test Specification : EN 61000-4-5

Coupling

Power Signal Line Telecommunication line

Test level

Power : ± 0.5 kV & ± 1 kV & ± 2 kV Signal Line : ± 0.5 kV & ± 1 kV

Tel. line :

Test mode

- Power : L-N, L-PE, N-PE

- Signal Line : Video in, RS-485/RS-422(Direct)

Coupling Impedance 40Ω+0.5 40Ω 10Ω+9 18

Coupling Time : > 1 min

Number of Surge : AC power : 20, Signal : 5

Angle : 0, 90, 180, 270

Test Results Complied Not complied

Comment :

- There was no change of operation status during above testing.

Page 27: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 26 of 54

6.7 Conducted Immunity

6.7.1 Measurement procedure

A ground reference plane was located on the floor.

For tabletop equipment, the test was performed on a ground reference

plane on a 0.8m wooden table.

The EUT was isolated 0.1 m isolating support.

The ground plane was connected to floor reference ground plane via low

impedance connection.

For floor standing equipment, EUT was placed on a 0.1 m wooden table.

This test were Performed using CDN for mains, clamp for signal.

and injection probe.

6.7.2 Used equipments

Equipment Model no. Serial no. Makers Next Cal. date Used

CS generator CWS 500 C S1 V0635101750 EM TEST 2007.11.02

CDN CDN M2/M3 0906-12 EM TEST 2007.11.02

Attenuator INA2070-1 2054 Schaffner -

EM Clamp KEMZ 801 17643 Schaffner -

EM Clamp KEMA 801 17899 Scahffner -

Current probe MD720 W1345167/M6/0068 Schaffner -

Page 28: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 27 of 54

6.7.3 Test Data

Test Specification : EN 61000-4-6

Frequency Range 150 kHz - 100MHz 150 kHz - 230MHz 150 kHz - 500MHz

Test point: Power, Video in, Video out, Alarm, TV out

Coupling Power : CDN

Signal : Clamp

Tel. line :

Test level 1V 3V 10V

Modulation AM : 1kHz, 80%

PM : 1Hz (0.5 s ON : 0.5 s OFF)

Frequency step log 1% step log 3% step log 5% step

Dwell Time 3 s 2 s 1 s

Test Results Complied Not complied

Comment :

-There was no change of operation status during above testing. (1V & 3V)

-During the test, EUT appeared flickering. After this test, EUT was operated

normally. (10V : Main, signal)

Page 29: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 28 of 54

6.8 Dips and Interruptions

6.8.1 Measurement procedure

The dips/interruption test is only applicable to AC mains.

The dips/interruptions were applied at zero crossing.

6.8.2 Used equipments

Equipment Model no. Serial no. Makers Next Cal. date

Used

dips/interruption Tester UCS 500 M6 V0545100858 EM TEST 08.01.03

6.8.3 Test data

Test specification : EN 61000-4-11

Test data

[240Vac]

Test Level (%UT)

Dip/Int. (%UT)

Duration /Period

Phase (°)

Count number

0 % 100 % 0.5/1/5 Period 0 / 180 3T

40 % 60 % 0.5/1/5/10 Period 0 / 180 3T

70% 30 % 0.5/1/5/10 Period 0 / 180 3T

Test results Complied Not complied

Comment :

- There was no change of operation status during above testing.

Page 30: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 29 of 54

[110Vac]

Test Level (%UT)

Dip/Int. (%UT)

Duration /Period

Phase (°)

Count number

0 % 100 % 0.5/1/5 Period 0 / 180 3T

40 % 60 % 0.5/1/5/10 Period 0 / 180 3T

70% 30 % 0.5/1/5/10 Period 0 / 180 3T

Test results Complied Not complied

Comment :

- There was no change of operation status during above testing.

Page 31: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 30 of 54

6.10 Harmonics

6.10.1 Measurement procedure The equipment is supplied in series with shunt(s) Rm or current transformer(s) from a

source having the same nominal voltage and frequency as the rated supply voltage

and frequency of the equipment. Measurements shall be made under normal load, or

conditions for adequate heat discharge, and under normal operating conditions. User’s

operation controls or automatic programmers shall be set to produce the maximum

harmonic component, for each successive harmonic component in turn. For the

purpose of harmonic current limitation, equipment is classified as follows :

Class A : Equipment not specified in one of the three other Classes shall be considered

as Class A equipment.

- Balanced three-phase equipment;

- Household appliances excluding equipment identified as Class D;

- Tools excluding portable tools;

- Dimmers for incandescent lamps;

- Audio equipment. Class B : Portable tools; Arc welding equipment which is not professional equipment.

Class C : Lighting equipment.

Class D : Equipment having a specified power according to 6.2.2 less than or equal to

600 w, of the following types:

- Personal computers and personal computer monitors;

- Television receivers.

6.10.2 Used equipments

Equipment Model no. Serial no. Makers Next Cal. date Used

Harmonics/Flicker meter

5001x-CTS-400-413 54984 C.I. 08.05.03

Test site Immunity area - - -

6.10.3 Test data - Refer to attached test data

Test results Complied Not complied

Page 32: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 31 of 54

Page 33: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 32 of 54

Page 34: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 33 of 54

Page 35: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 34 of 54

6.11 Flicker

6.11.1 Measurement procedure

EUT was connected to the power analyzer system.

Measurement was performed to obtain the desired flicker parameters.

The measuring time depends on which parameters are to be measured.

Plt = 2 h

Pst = 10 min

Controls and automatic programs shall be set to produce the most

unfavorable sequence of voltage changes, using only those combinations of

controls and programs are mentioned by the manufacturer in the instruction

manual.

6.11.2 Used equipments

Equipment Model no. Serial no. Makers Next Cal. date Used

Harmonics/Flicker meter

5001x-CTS-400-413 54984 C.I. 08.05.03

Test site Immunity area - - -

6.11.3 Test data - Refer to attached test data

Test results

Complied Not complied

Page 36: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 35 of 54

Page 37: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 36 of 54

7. Test photographs Conducted emission

Page 38: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 37 of 54

Radiated Emission

Page 39: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 38 of 54

Electrostatic Discharge

Radio Frequency Electromagnetic Fields

Page 40: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 39 of 54

Electric Fast Transient

Page 41: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 40 of 54

Surge

Page 42: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 41 of 54

Conducted Immunity

Page 43: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 42 of 54

Dip & Interruptions

Harmonics/Flicker

Page 44: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 43 of 54

8. E.U.T. photographs Front

Rear

Page 45: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 44 of 54

Inside

Page 46: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 45 of 54

Main Board

Page 47: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 46 of 54

SCSI Board

Page 48: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 47 of 54

ODD Board

Page 49: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 48 of 54

IR Board

Page 50: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 49 of 54

BNC Board

Page 51: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 50 of 54

Adapter

Page 52: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 51 of 54

Line in Cable

Serial Cable

Page 53: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 52 of 54

LAN Cable

BNC Cable

Page 54: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 53 of 54

Console Cable

D-SUB Cable

Page 55: 2 EU Declaration of Conformity (EMC) · POSDATA CO., LTD which will be made available upon request. POSDATA CO., LTD 276-2, seohyeon-dong, Bundang-gu Seongnam-city, Kyeonggi-do 463-775,Korea

EMC Compliance Ltd.

82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825 KOREA TEL: 82 31 336 9919 FAX : 82 31 336 4767

This test report shall not be reproduced except in full, Without the written approval.

Report No.: EMC-CE-1524 Page : 54 of 54

S-video Cable

Audio Cable