Alarm & Monitoring Systems
Data station Data station Data converter
Display Display
CAN-Bus
Modular System
-
8/8/2019 2 Boening en SAS
2/83
Alarm & Monitoring Systems
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
-
8/8/2019 2 Boening en SAS
3/83
Alarm & Monitoring Systems
Data converter
AHD-UIC
AHD-UCC
-
8/8/2019 2 Boening en SAS
4/83
Alarm & Monitoring Systems
Displays with integrated PC, Monitors
AHD 1019 M
AHD 1015 TC
AHD 919
AHD 915 TC
-
8/8/2019 2 Boening en SAS
5/83
Alarm & Monitoring Systems
Display and Control Units
AHD 651
AHD 880 TC
Kompakt EDA 47
Accessories
AHD 650 R
-
8/8/2019 2 Boening en SAS
6/83
Alarm & Monitoring Systems
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
-
8/8/2019 2 Boening en SAS
7/83
AHD-SAS 15 Data station
15 inputs
for analog and binary sensors
CAN
2 serial
outputs
2 serial
inputs
-
8/8/2019 2 Boening en SAS
8/83
AHD-SAS 15 Data station
15 input channels individuallyfitted with pluggable analog
input modules for acquisition
of analog and binary signals
15 inputs
for analog and binary sensors
Input/Sensor signal Type Analog
module/
Article number
activ e pass iv e
4-20 mA, 2-pole sensor
- Sensor without external power supply
B / 11109 x
4-20 mA, 4-pole sensor
- Sensor with external power supply
C / 11110 x
Contact via voltage measurement
- Contact switches UBat
E / 11111 x
Contact potentialfree,
- Contact switches UBat-
- Transistor switches UBat-
F / 11112 x
PT100
- Resistance sensor, Measuring range -50C +200C
G / 11119 x
PT1000
- Resistance sensor, Measuring range -50C +200C
H / 11120 x
Thermo couple NiCrNi, Type K
Measuring range 0C +1000C
I / 11121 x
Voltage 0 5 V DC J / 11122 x
Voltage 0 10 V DC K / 11123 x
Voltage 0 30 V DC (discontinued) L / 11124 x
Voltage 0 40 V DC T / 13142 xRacor/Parker water level sensor M / 10893 x
-
8/8/2019 2 Boening en SAS
9/83
AHD-SAS 15 Data station
Connection schemes
for analog and binary sensors withcorresponding analog input module
-
8/8/2019 2 Boening en SAS
10/83
AHD-SAS 15 Data station
Connection schemes
for analog and binary sensors withcorresponding analog input module
-
8/8/2019 2 Boening en SAS
11/83
AHD-SAS 15 Data station
Connection schemes
for analog and binary sensors withcorresponding analog input module
-
8/8/2019 2 Boening en SAS
12/83
AHD-SAS 15 Data station
Connection schemes
for analog and binary sensors withcorresponding analog input module
-
8/8/2019 2 Boening en SAS
13/83
AHD-SAS 15 Data station
Applicable as autarkic
alarm and monitoring system
1 Horn relay output
1 Common alarm relay output
2 free configurable relay outputs
1 Acknowledgement input for external alarm
acknowledgement
System operates independently
from other components
Alarm signaling also at complete shutdownof system bus
Local alarm indications by LEDs
-
8/8/2019 2 Boening en SAS
14/83
AHD-SAS 15 Data station
Configuration via PC Software
Measuring point text (2 languages applied)
Unit
Standardization (i.e. Tank curve)
Indication range / Validity range Wire breakage monitoring
Alarm signaling / Alarm limits
(min./max. Alarm, Warning)
Alarm delay
Alarm suppression
Filter settings (rising/ trailing edge)
Configuration via CAN-BUS-Line
-
8/8/2019 2 Boening en SAS
15/83
AHD-SAS 15 Data station
Internal measuring value processing
All acquired measuring data are internally
processed and standardized.
On demand, special characteristic curvescan be applied by configuration, i.e. for non
linear sensors or tank content
measurements.
Additionally it is possible to create virtual
channels, whose resulting values arecalculated from multiple physical sensors.
A virtual channel may be used e.g. for
calculation of total fuel reserve by
summation of several tank contents or
mean value calculation of exhaust gas
temperatures.
-
8/8/2019 2 Boening en SAS
16/83
AHD-SAS 15 Data station
Integrated alarm memory
An integrated alarm memory may record
up to 10,000 messages within a data
station AHD-SAS 15.
These may be warning, alarm, sensorfault or also status messages.
The storage considers here all locally
arising events and stores them with date,
time, duration and acknowledgement
state. The readout of memory can be
performed locally via existing RS232interface.
(Readout via CAN-BUS in progress).
-
8/8/2019 2 Boening en SAS
17/83
Alarm & Monitoring Systems
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
-
8/8/2019 2 Boening en SAS
18/83
AHD-PS 47 Binary data station
47 binary inputs
3 serial
outputs
-
8/8/2019 2 Boening en SAS
19/83
AHD-PS 15 / AHD-PS 30 Binary data stations
15 binary inputs
3 serialoutputs
3 serialoutputs
30 binary inputs
-
8/8/2019 2 Boening en SAS
20/83
AHD-PS 47 / PS 30 / PS 15 Binary data station
For acquisition of binary signals
(potentialfree contacts resp. system
voltages switched by contacts or
transistors etc.)
In- and outputs via optocoupler
Conversion into serial signal for further
processing (i.e. by AHD-SAS 15)
Serial data transmission up to 1000m
Installation next to sensors possible
Minimized cabling demands
-
8/8/2019 2 Boening en SAS
21/83
AHD-PS 47 / PS 30 / PS 15 Binary data station
Test button for checkof short to
earth/ground
LED Status indications
-
8/8/2019 2 Boening en SAS
22/83
AHD-PS 47 / PS 30 / PS 15 Binary data station
Connection of binary inputs1) Potential free contacts, Normally Open (NO) and
Normally Closed (NC).
2) Potential free contacts, Normally Open (NO) and
Normally Closed (NC), with combined common pole.
3) Transistor inputs, minus-switching, with common
minus potential. Those sensors are switched like
contacts. The minus terminal of input (N) remains
unconnected.
4) Potential free contacts, Normally Open (NO) andNormally Closed (NC), with combined common pole
with minus potential. The minus terminal of input (N)
remains unconnected.
5) Potential free contacts, Normally Open (NO) and
Normally Closed (NC), with combined common pole
with plus potential. The input terminals (P + N) are
shorted to allow measurement of change of potential
in case of switching of contact.
6) Transistor inputs, plus-switching, with common plus
potential. The input terminals (P + N) are shorted to
allow measurement of change of potential in case ofswitching of transistor.
-
8/8/2019 2 Boening en SAS
23/83
-
8/8/2019 2 Boening en SAS
24/83
AHD-R 101 Relay station
15 potentialfree
change-over contacts
2 serial
inputs
-
8/8/2019 2 Boening en SAS
25/83
AHD-R 101 Relay station
Serial-Parallel-Data Conversion
Serial data transmission up to1000m
(i.e. from AHD-SAS 15)
Status-LED indications
14 relay outputs free configurable
Output No. 15 used for device failure
signaling
-
8/8/2019 2 Boening en SAS
26/83
Alarm & Monitoring Systeme
Data stations
AHD-SAS 15
AHD-PS 47 / AHD-PS 30 / AHD-PS 15
AHD-R 101
AHD 882
-
8/8/2019 2 Boening en SAS
27/83
AHD 882 Central unit
CAN18 serialinputs
16 serialoutputs
5 Group relay outputs
1 Configurable alarm relay output
1 Horn relay output
1 Input for audible alarm acknowledgement
1 Input for visual alarm acknowledgement
-
8/8/2019 2 Boening en SAS
28/83
-
8/8/2019 2 Boening en SAS
29/83
AHD 882 Central unit
Integrated alarm memory
Storage of last 10,000 messages with
date/time
Distinguishing between status and alarm
messages as well as Switch-On and
Switch-Off messages
Memory complete warning
If memory is filled up and a new alarm
arises, the eldest stored alarm will be
deleted and the new alarm is stored
(First-in/first-out-principle).
-
8/8/2019 2 Boening en SAS
30/83
AHD 882 Central unit
Output for alarm and event data
Serial output for
Alarm printer
Laptop / PC
LCD Display with serial input
Voyage Data Recorder VDR
RS232 or RS422 selectable
Activation via DIP switch
RS232
RS422
-
8/8/2019 2 Boening en SAS
31/83
AHD 882 Central unit
Configuration via PC Software
Configuration
via CAN-BUS-Line
-
8/8/2019 2 Boening en SAS
32/83
Alarm & Monitoring Systems
Data converter
AHD-UIC
AHD-UCC
-
8/8/2019 2 Boening en SAS
33/83
AHD-UIC Interface converter
Data communication with externalsystem
CAN
3 interfaces: 1 x RS232, 2 x
RS485
AHD-SAS CAN bus network
-
8/8/2019 2 Boening en SAS
34/83
-
8/8/2019 2 Boening en SAS
35/83
Alarm & Monitoring Systems
Data converter
AHD-UIC
AHD-UCC
-
8/8/2019 2 Boening en SAS
36/83
AHD-UCC Universal CAN converter
Data communication
with external system
CAN
AHD-SAS CAN bus network
CAN
-
8/8/2019 2 Boening en SAS
37/83
AHD-UCC Universal CAN converter
Data acquisition from external
systemsLogging of defined data on CAN bus of
external system with data conversion to Bning
AHD-SAS CAN bus network
CAN bus interfaces galvanically isolated
Conversion of data protocols of external
systems
NMEA 2000
SAE J1939
Protocols of engine manufacturers
(i.e. Caterpillar, Cummins etc.)
Applicable as repeater unit with extended cable
lenghts within AHD-SAS CAN bus network
-
8/8/2019 2 Boening en SAS
38/83
Alarm & Monitoring Systems
Displays with integrated PC, Monitors
AHD 1019 M
AHD 1015 TC/MTC
AHD 919
AHD 915 TC
-
8/8/2019 2 Boening en SAS
39/83
AHD 1019 M Colour display
19 LED backlight LCD colour display
with integrated PC (Panel computer)
High resolution display
(SXGA, 1280(H) x 1024(V) Pixel, 1000
cd/m2)
Readable even at solar radiation
Multiple visualization pages with project-specific resp. standard design
Integrated PC with Pentium Mobile 1.7 GHz
processor, 1 GB RAM/1 GB flash disk
Innovative operation concept with operation
units connected to control CAN (CAN5)
Robust design, no moveable parts Automatic control of backlight illumination
Approved for display of Radar and ECDIS
sea chart images (ECDIS push button)
-
8/8/2019 2 Boening en SAS
40/83
AHD 1019 M Colour display
Rear view: Interfaces:
Power supply 24 V DC(9 32 V DC)
5 x CAN Bus
CAN1: Engine 1
CAN2: Engine 2
CAN3: AHD-SAS network
CAN4: AHD-SAS network(redundant)
CAN5: Control CAN operation
1 x RS232
1 x LAN
2 x USB 2.0
Opt. In (4x Optocoupler input)Relay Out (2x Relay output)
1 x Video In (BNC), PAL 50 Hz
1 x DVI In (DVI-D, Dual Link)
1 x VGA In
-
8/8/2019 2 Boening en SAS
41/83
Alarm & Monitoring Systems
Displays with integrated PC, Monitors
AHD 1019 M
AHD 1015 TC/MTC
AHD 919
AHD 915 TC
-
8/8/2019 2 Boening en SAS
42/83
-
8/8/2019 2 Boening en SAS
43/83
AHD 1015 TC/MTC Colour display
Rear view (AHD 1015 MTC): Interfaces:
Power supply 24 V DC(9 32 V DC)
5 x CAN Bus
CAN1: Engine 1
CAN2: Engine 2
CAN3: AHD-SAS network
CAN4: AHD-SAS network(redundant)
CAN5: Control CAN operation
1 x RS232
1 x LAN
2 x USB 2.0
Opt. In (4x Optocoupler input)Relay Out (2x Relay output)
Only with type MTC:
1 x Video In (BNC), PAL 50 Hz
1 x DVI In (DVI-D, Dual Link)
1 x VGA In
-
8/8/2019 2 Boening en SAS
44/83
Visualisation pages (examples)
Main page Tanks
-
8/8/2019 2 Boening en SAS
45/83
Visualisation pages (examples)
Bilges Navigation Lights
-
8/8/2019 2 Boening en SAS
46/83
Visualisation pages (examples)
Power Engine analog
-
8/8/2019 2 Boening en SAS
47/83
-
8/8/2019 2 Boening en SAS
48/83
Visualisation pages (examples)
Events Measuring Points
-
8/8/2019 2 Boening en SAS
49/83
Visualisation pages (examples)
Settings
-
8/8/2019 2 Boening en SAS
50/83
Alarm & Monitoring Systems
Displays with integrated PC, Monitors
AHD 1019 M
AHD 1015 TC/MTC
AHD 919
AHD 915 TC
AHD C l i
-
8/8/2019 2 Boening en SAS
51/83
AHD 919 Colour monitor
19 LCD colour monitor
High resolution display
(SXGA, 1280(H) x 1024(V) Pixel, 1000
cd/m2)
Readable even at solar radiation
Approved for display of Radar and ECDISsea chart images (ECDIS push button)
Video input
Source selection by operating panels via
control CAN
Robust design, no moveable parts
Automatic control of backlight illumination
-
8/8/2019 2 Boening en SAS
52/83
Al & M i i S
-
8/8/2019 2 Boening en SAS
53/83
Alarm & Monitoring Systems
Displays with integrated PC, Monitors
AHD 1019 M
AHD 1015 TC/MTC
AHD 919
AHD 915 TC
-
8/8/2019 2 Boening en SAS
54/83
AHD 915 C l it
-
8/8/2019 2 Boening en SAS
55/83
AHD 915 Colour monitor
Rear view (AHD 915): Interfaces:
Power supply 24 V DC(9 32 V DC)
1 x CAN Bus
(Control CAN operation)
1 x RS232
Opt. In (4x Optocoupler input)
Relay Out (2x Relay output)Touch Out
1 x Video In (BNC), PAL 50 Hz
1 x DVI In (DVI-D, Dual Link)
1 x VGA In
Al & M it i S t
-
8/8/2019 2 Boening en SAS
56/83
Alarm & Monitoring Systems
Display and Control Units
AHD 651
AHD 880 TC
Kompakt EDA 47
Accessories
AHD 650 R
AHD 651 C l di l
-
8/8/2019 2 Boening en SAS
57/83
AHD 651 Colour display
Graphic LCD colour display
with 6.5 screen diagonal
Transflective display for best readability even at solar radiation
Front glass anti-reflection coated
Degree of protection IP 67 (Front)
Automatic dimming control of backlight illumination
AHD 651 Colour display
-
8/8/2019 2 Boening en SAS
58/83
AHD 651 Colour display
Individual graphical or tabular page design
multiple graphical presentation elements selectable
(Icons, bar graph indicator, round gauges etc.)
Integration of images and logos on max. 17 pages
AHD 651 Colour display
-
8/8/2019 2 Boening en SAS
59/83
AHD 651 Colour display
Alarm page
Integrated alarm buzzer; tabular alarm page
Alarm indication with clear text incl. status, date and time
AHD 651 Colour display
-
8/8/2019 2 Boening en SAS
60/83
AHD 651 Colour display
Configuration page
Two languages selectable (Cyrillic also available)
Switching of unit system
Indication of CAN ID and setting of time
Long time keypress
AHD 651 Colour display
-
8/8/2019 2 Boening en SAS
61/83
AHD 651 Colour display
Service page
Indication of all monitored measuring points within the ship alarm system
tabular form; english language
Version information of software
Firmware / projectspec. graphic page software / projectspec. configuration softwa
AHD 651 Colour display
-
8/8/2019 2 Boening en SAS
62/83
AHD 651 Colour display
AHD 651 Farbdisplay
-
8/8/2019 2 Boening en SAS
63/83
AHD 651 Farbdisplay
Alarm & Monitoring Systems
-
8/8/2019 2 Boening en SAS
64/83
Alarm & Monitoring Systems
Display and Control Units
AHD 651
AHD 880 TC
Kompakt EDA 47
Accessories
AHD 650 R
-
8/8/2019 2 Boening en SAS
65/83
-
8/8/2019 2 Boening en SAS
66/83
AHD 880 TC Colour display
-
8/8/2019 2 Boening en SAS
67/83
AHD 880 TC Colour display
Alarm page
Integrated alarm buzzer; tabular alarm page
Alarm indication with clear text incl. status, date and time
AHD 880 TC Colour display
-
8/8/2019 2 Boening en SAS
68/83
AHD 880 TC Colour display
Configuration pages
Two languages selectable
Switching of unit system
Indication of CAN ID and setting of date and time
Min/Max. brightness settings of displays adjustable
-
8/8/2019 2 Boening en SAS
69/83
AHD 880 TC Colour display
-
8/8/2019 2 Boening en SAS
70/83
AHD 880 TC Colour display
Video input
Composite Video; BNC socket - PAL 50Hz
AHD 880 TC Colour display
-
8/8/2019 2 Boening en SAS
71/83
AHD 880 TC Colour display
AHD 880 TC Colour display
-
8/8/2019 2 Boening en SAS
72/83
AHD 880 TC Colour display
Comparison of colour displays
-
8/8/2019 2 Boening en SAS
73/83
Comparison of colour displays
-
8/8/2019 2 Boening en SAS
74/83
AHD 650 R Remote control
-
8/8/2019 2 Boening en SAS
75/83
AHD 650 R Remote control
Remote control for colour displays
5 integrated operating keys for remote control of colour displays
(except power on/off function)
Degree of protection IP 67 (Front)
Connection via 8-pole connection cable (both endings plugable)
applicable for AHD 651 and AHD 880 TC
AHD 650 R Remote control
-
8/8/2019 2 Boening en SAS
76/83
650 e ote co t o
AHD 650 R Remote control
-
8/8/2019 2 Boening en SAS
77/83
Alarm & Monitoring Systems
-
8/8/2019 2 Boening en SAS
78/83
g y
Display and Control Units
AHD 651
AHD 880 TC
Kompakt EDA 47
Accessories
AHD 650 R
Kompakt EDA 47
-
8/8/2019 2 Boening en SAS
79/83
p
Compact alarm and
display system
48 illuminated and automatically dimmed text fields
Unused fields shaded deep black
Free inscription on common film negative; Block LED colours red, green, yellow
Integrated alarm buzzer
Configuration of EEPROM (Type 28C64) by programming device Dataman S4"
2 serial
inputs
3 serialoutputs
Kompakt EDA 47
-
8/8/2019 2 Boening en SAS
80/83
p
Kompakt EDA 47
-
8/8/2019 2 Boening en SAS
81/83
p
Kompakt EDA 47
-
8/8/2019 2 Boening en SAS
82/83
p
Audible acknowledgement (Hornquit)
Visual acknowledgement
Lamp test
External operating elements required
Kompakt EDA 47
-
8/8/2019 2 Boening en SAS
83/83
On- and Off-delay 1-99 sec.
Contact type (NC/NO)
Alarm suppression
serial group outputs
Configuration