Page 1: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 2: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../D

/S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8/

D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

S

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

D/S

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 3: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

E1-E2

E1-E2

E1-E2-E3

2

1

OnOff

D2936C O N D U C T I V E L E V E L C O N T R O L L E R C L C 3 8

IP65 Protection

Stainless steel electrodes

Made with 2 or 3 electrodes

ON REQUEST THE ELECTRODES ARE SUPPLIED WITH

THE LENGTH ESTABLISHED BY THE CUSTOMER :

LED lit with excited relay

ELECTRODE ARRANGEMENT

See from below

Long

MediumShort

APPLICATIONS

MAINTAINING LEVEL BETWEENTWO SET POINTS

MAX ALARM LEVEL

MIN. ALARM LEVEL

Alarm

Alarm

Using two electrodesmeans having to connectthe inactive electrode(E3) with the commonone (E1).

WIRING

E1 L= ,E2 L= ,E3 L= .

1 -

2 -

3 -

4 -

5 -

6 -

7 -

Sensitivity regulation trim

Max pressure 8 bar

Weight : 2,200 Kg

Ambient temperature range -5 to +70˚C

Ground

Common power supply

P.supply 110 Va.c.50/60Hz

P.supply 220 Va.c.50/60Hz

Common contacts

Electric draw 1 W to 220 Va.c.

On request power supply at 24/48 V.

L =

ø8

ø96

ø1/2" Gas

30

ø101

CLC38

.. 0.. 220110

ALIMENTAZIONE

7654321

O1OO

5O

ø1"1/2 Gas

9512

30

167

920

E1

E2E3

90˚C

NYLON6+30%Glass-fiber casing

Max. temperature

SW 60

5A.250V.a.c.

NO contact 5A/250Va.c.

NC contact 5A/250Va.c.

LEVEL GAUGESvast range, long-lasting

Rev. 00

www.camlogic.it e-mail [email protected]

Page 4: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

D2948

ø125

ø165

P F G 8 0 / F F L A M E P R O O F L E V E L G A U G E

Model AC3 4 vane

Stainless steel screw

4 holes ø18 to 90˚

Weight : 5,700 Kg

30

ø190

55

85 135 20

50 18 67 80

60

300

100

Common power supply

Power supply 110 Va.c. 50/60 Hz

Power supply 220 Va.c. 50/60 Hz

Not used

Common contacts

7 -

6 -

5 -

4 -

3 -

2 -

1 -

WIRING

NC contact 10A/250 Va.c.

NO contact 10A/250 Va.c.

Electric motor draw 4 W

On request power supply at 24/48 Va.c. 50/60 Hz

manufactured according to CEI rules.PFG80 is a flameproof level gauge,

PFG80 is particularly designed forplants or rooms where, owning tochemical processing or particularproducts flammable and explosive

dangerous to use electric operatingunits not properly designed for this.

tunings may develop, making it

PFG80

VUOTO

PIENO

0

REGGIO EMILIA (Italy)

N.Tipo

BREVETTO N. 656961

220

110 2

1

7

6

5

4

3

10A.250Vc.a.

EEx d IIB T6Temperature class T6 = 85˚C

IP65 Protection

Certi

ficat

e of c

onfo

rmity

CES

I Ex-

97.D

.060

Cable inlet ø1/2"UNI6125

LEVEL GAUGESvast range, long-lasting

Rev. 00

www.camlogic.it e-mail [email protected]

Page 5: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

D2983M N . 3 0 L E V E L I N D I C A T O R W I T H M E M B R A N E

CONSTRUCTION

USE

FITTING

VERSIONS

: Cast in aluminium alloy

: 1 exchange contact N.O. - N.C. 15A-250V

: MN.30 with membrane in rubber

AIR INTAKE FROM THE TANK TO BALANCE THE PRESSURE ACTING ON THE MEMBRANE

DOUBLE 1/2" GAS CABLE ENTRY POSITIONED ON THE TWO SIDES

Vertical or with maximum inclination of 45˚

MN.30S with silicone membrane - max. temperature 100˚C

: 2,700 KgWEIGHT

IP55 PROTECTION

Ambient temperature range -10 to +70˚C

THE TENSION OF THE MEMBRANE CAN BE REGULATED BY MEANS OF AN INTERNAL COUNTERWEIGHT

:

6 holes ø8,5 equidistant

Pressure socket ø12

LEVEL GAUGESvast range, long-lasting

110

5555

ø20

0

ø13

0

120ø260

ø1/

2" G

as

ø1/

2" G

asø

230

30˚

R.112

ø20

0

ø70

Rev. 00

www.camlogic.it e-mail [email protected]

Page 6: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

D2994P F G - 5 6 / F C A P A C I T I V E L E V E L G A U G E

Stainless steel flange

OPERATING DISTANCE

0-25 mm.

Sensitivity

regulation trim

LED lit with

excited relay

position enables the static

test on the equipment by

exciting the relay

( maximum sensitivity )

4 holes ø7 to 90

PFG565O

1OOO

1 2 3 4 5 6 7

ALIMENTAZIONE

110 220 0....

WIRING

Common power supply

Ground

Common contacts

7 -

6 -

5 -

4 -

3 -

2 -

1 -

Power supply 110 Va.c.50/60Hz

Power supply 220 Va.c.50/60Hz

Electric draw 1 W to 220 Va.c.

Ambient temperature range -20 to +70 C

On request power supply at 24/48 V.

IP65 Protection Maximum operational pressure 8 bar

Weight : 1,100 Kg

The trim stop clockwise

5A.250V.a.c.

NO contact 5A/250Va.c.

NC contact 5A/250Va.c.

LEVEL GAUGESvast range, long-lasting

Rev. 01

ø120

ø140

100

30

25

50

205

ø28

ø1/2

" G

as

5ø101

Cer

tific

ate

num

ber T

ÜV

03 A

TEX

2374

Xwww.camlogic.it e-mail [email protected]

Page 7: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

Common power supply

Power supply 110 Va.c. 50/60 Hz

Power supply 220 Va.c. 50/60 Hz

Not used

Common contacts

7 -

6 -

5 -

4 -

3 -

2 -

1 -

WIRING

NC contact 10A/250 Va.c.

NO contact 10A/250 Va.c.

30

ø190

60

65

18ø

2"1/

2 G

as

ø82

,5

55 35 100 120

85 135 20 100

340

ø2"

1/2

Gas

D3030P F G 8 0 / M F L A M E P R O O F L E V E L G A U G E

Screw ø5MA

Model AC4 1 vane

Stainless steel screw

SLEEVE

Electric motor draw 4 W

On request power supply at 24/48 Va.c. 50/60 Hz

manufactured according to CEI rules.PFG80 is a flameproof level gauge,

PFG80 is particularly designed forplants or rooms where, owning tochemical processing or particularproducts flammable and explosive

dangerous to use electric operatingunits not properly designed for this.

tunings may develop, making it

Weight : 3,500 Kg

PFG80

VUOTO

PIENO

0

REGGIO EMILIA (Italy)

N.Tipo

BREVETTO N. 656961

220

110 2

1

7

6

5

4

3

10A.250Vc.a.

EEx d IIB T6Temperature class T6 = 85˚C

IP65 Protection

Certi

ficat

e of c

onfo

rmity

CES

I Ex-

97.D

.060

Cable inlet ø1/2"UNI6125

LEVEL GAUGESvast range, long-lasting

Rev. 00

www.camlogic.it e-mail [email protected]

Page 8: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

110-220 V. 50/60Hz.24-48:

5-6

4-5

1-2-3

D3044S M D 2 0 D I G I T A L R E V M O N I T O R

Thisoptionalcan beadded latersimply bychangingthe face

WIRING

Power supply

24 V.d.cN.O. contact

N.C. contact

=

=

=

LED ON WITHRELAY ENERGIZED

RPMREGULATION

DIGITAL DISPLAY REV MONITOR

SMD20

LED ACCESO ARELE' ECCITATO

Ita

0 110 220"

st

SMD20

4-5-6 CONTATTIRELE' A RIPOSO

Co

1"

2 3 4 5 6

0

5

ALIMENTAZIONE

zio

ru

on

El

ni

et tr

7 6

8

heic

9

5A 250V.a.c.

786

9

734

21

8 345

120

3

56 4

09 12

DISPLAY

(

)ly

RE

Ca vr i ago

RPM SET

SET-POINT

The CAMLOGIC SMD20 Digital Rev Monitor guarantees on-going supervisionof the functional parameters of any rotating part of a machine.The special version can control continuous straight-line movement.If there is a mechanical breakdown, shutdown or a decrease in the machine'sRpm, the Rev Monitor can shutdown the entire system or generate anemergency signal by means of an output switch-over contact.

HOW DOES IT WORK ?Once the operating revs have been set for the machine to be controlled,

the switch-over contacts change and the LED is lit. If the revs are lowerthan the setting, the switching-contact break relay trips and the LEDgoes out. The rev monitor starts up with the relay energized for 10

seconds with the contacts inmake and the LED lit.

whenever the revs detected are equal to or higher than these settings,

SPECIAL FEATURES

Aluminium casting enclosure.

Weight with bracket 1,7 Kg.

Operating field 1-5000 Rpm.

Temperature from -10 +80˚C.

Speed detection by amechanically coupled impulsegenerator.

Stainless steel shaft mounted

IP65 protection.

Versions for various installationneeds.

Available with coupling fitting

On request power supply at24 V.d.c.

Because of its proven safety and reliability the SMD20 Digital Rev Monitoris the ideal solution for every industrial needs.

on ball bearings.

Electric max. draw 4 W to 220Va.c.

5A-220Va.c.

5A-220Va.c.

REV MONITORSvast range, long-lasting

Rev. 00

www.camlogic.it e-mail [email protected]

Reggio Emilia

CAMLOGIC

RPM

Italy

SMD20

REV MONITOR

Type SMD20 V.110/220

Year of production 2000

Via dell' Industria 12 - 42025 CAVRIAGO RE - Italy

Page 9: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

TYPES OF INSTALLATION

CONVEYOR BELT VERSION

INSTALLATION WITH SUPPORT BRACKET

FLANGED INSTALLATION

DIRECT INSTALLATION VERSION

COUPLING

turned at 90˚ intervalsassembled with cable inputMovement signal can be

4 holes ø6,5 to 90˚

4 holes M6 to 90˚

2 holes ø8,5

2 holes ø8,5

7025

95

M10

CAMLOGIC Digital Rev Monitorcan be installed in anyposition.Once connected to the powersupply terminal block, theunits are completelymaintenance free.

105

105

120

130

50

2030

ø1/

2" G

as

140

75

= =70

127

127

70 ==

75

140

90˚

45˚

45˚

ø120

7575

90

ø135

200

ø80

40

ø1/

2" G

as

5

25

25

ø40

25 5

30 20

50

130

120

ø10

ø10

5

2 5 ø1/2" Gas

ø10ø80

ø10

5

120

ø1/2" Gas

ø10

ø10

5

115

Page 10: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

D3059P F G - 5 6 / X C A P A C I T I V E L E V E L G A U G E

SLEEVE

LED lit with

excited relay

Sensitivity

regulation trim

OPERATING DISTANCE

0-25 mm.

position enables the static

test on the equipment by

exciting the relay

( maximum sensitivity )

PFG565O

1OOO

1 2 3 4 5 6 7

ALIMENTAZIONE

110 220 0....

100

415

15 L = 300

50

ø101

ø1/2" Gas

20 230

ø2" Gas ø28ø32

43

ø2

" G

as

ø70

WIRING

Common power supply

Ground

Common contacts

7 -

6 -

5 -

4 -

3 -

2 -

1 -

Power supply 110 Va.c.50/60Hz

Power supply 220 Va.c.50/60Hz

Electric draw 1 W to 220 Va.c.

Ambient temperature range -20 to +70°C

On request power supply at 24/48 V.

IP65 Protection

ON REQUEST : L = Length to be defined

Maximum operational pressure 10 bar

ALUMINIUM casing

TEFLON sensor

STAINLESS STEEL ring nut and pipe

Weight : 2,100 Kg

The trim stop clockwise

5A.250V.a.c.

NO contact 5A/250Va.c.

NC contact 5A/250Va.c.

LEVEL GAUGESvast range, long-lasting

Rev. 01

Cer

tific

ate

num

ber T

ÜV

03 A

TEX

2374

Xwww.camlogic.it e-mail [email protected]

Page 11: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

ø152

10013587

342

20

35 ø2"1/2 Gas

90

ø178

ø203

65

18

ø2

"1/2

Ga

s

ø8

2,5

3 mm.

D3158B L A D E D L E V E L G A U G E W I T H I N D I C A T O R L I G H T P F G 8 6 / L

The extension can be installed

at a later date

L = Length to be defined

Cable inlet ø1/2" Gas - double

horizontal on right side

Screw ø5MA

Indicator light - Red

Common power supply

Power supply 110 Va.c. 50/60 Hz

Power supply 220 Va.c. 50/60 Hz

Not used

Common contacts

7 -

6 -

5 -

4 -

3 -

2 -

1 -

NC contact 10A/250 Va.c.

NO contact 10A/250 Va.c.

On request power supply at 24/48 Va.c. 50/60 Hz

Ambient temperature range -20 to +70°C

6 equidistant ø7 holes

Electric motor draw 4 W

IP65 Protection

PFG86

VUOTO

PIENO

0

REGGIO EMILIA (Italy)

N.Tipo

BREVETTO N. 656961

220

110 2

1

7

6

5

4

3

10A.250Vc.a.

Maximum operational pressure 3 bar

WIRING

FLANGESLEEVE

On request power supply at 24 Vd.c.

CESI

Cer

tifica

te o

f con

form

ity G

R-92

/029

763

Stainless steel ø10

VERSIONS WITH SLEEVE OR FLANGE

AND WITH PROTECTED EXTENSION

Weight : PFG86/L/M 2,550 Kg - PFG86/L/F 2,900 Kg

PFG86/L = with 2"1/2 Gas thread - PFG86/L/M = with 2"1/2 Gas sleeve - PFG86/L/F = with flange

LEVEL GAUGESvast range, long-lasting

Rev. 00

www.camlogic.it e-mail [email protected]

Page 12: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

ø28

ø101

ø1

/2"

Ga

s

ø96

30

MANICOTTO

Lunghezza da definire

rele' eccitato

Led acceso a

Zona sensore

sensibilita'

Trim regolazione

INTERVENTO 0-25 mm.

DISTANZA DI

Comune contatti

Neutro alimentazione

Terra

CABLAGGIO

7 -

6 -

5 -

4 -

3 -

2 -

1 -5O

1OOO

1 2 3 4 5 6 7

ALIMENTAZIONE

110 220 0....

PFG56

permette la prova statica

dell'apparecchio eccitando

il rele'

( massima sensibilita' )

VERSIONE CONPROLUNGA

Tubo ø32

A richiesta alimentazione 24/48 V.

Temperatura di esercizio da -20 a +70°C

Alimentazione 110 Vc.a.50/60Hz

Alimentazione 220 Vc.a.50/60Hz

Protezione IP65

Assorbimento 1 W a 220 Vc.a.

Pressione massima di esercizio 1,1 bar

La posizione a finecorsa

del trim, in senso orario,

5A.250V.a.c.

Contatto N.A. 5A/250Vc.a.

Contatto N.C. 5A/250Vc.a.

INDICATORI DI LIVELLOvasta gamma, durata elevata

D3489I N D I C A T O R E D I L I V E L L O A C A P A C I T A ' P F G - 5 6 / 1 " 1 / 2

95

12

53

19

0

ø1"1/2 Gas

Chiave 60

Custodia in NYLON6+30%FV

Sonda in PETP

Peso : 0,750 Kg

ø55

49

Rev. 02

Num

ero

di c

ertif

icato

TÜV

03

ATEX

237

4 X

www.camlogic.it e-mail [email protected]

Page 13: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

ø28

ø101

ø1

/2"

Ga

s

ø96

30

7 -

6 -

5 -

4 -

3 -

2 -

1 -5O

1OOO

1 2 3 4 5 6 7

ALIMENTAZIONE

110 220 0....

PFG56

5A.250V.a.c.

95

12

53

19

0

ø1"1/2 Gas

ø55

49

D3490

LEVEL GAUGESvast range, long-lasting

P F G - 5 6 / 1 " 1 / 2 C A P A C I T I V E L E V E L G A U G E

SLEEVE

Sensor area

LED lit with

excited relay

Sensitivity

regulation trim

OPERATING DISTANCE

0-25 mm.

position enables the static

test on the equipment by

exciting the relay

( maximum sensitivity )

VERSION WITHEXTENSION

WIRING

Common power supply

Ground

Common contacts

Length to be defined

Power supply 110 Va.c.50/60Hz

Power supply 220 Va.c.50/60Hz

Electric draw 1 W to 220 Va.c.

Ambient temperature range -20 to +70°C

On request power supply at 24/48 V.

IP65 Protection Maximum operational pressure 8 bar

The trim stop clockwise

NO contact 5A/250Va.c.

NC contact 5A/250Va.c.

Pipe ø32

Weight : 0,750 Kg

SW 60

NYLON6+30%Glass-fiber casing

PETP sensor

Rev. 01

Cer

tific

ate

num

ber T

ÜV

03 A

TEX

2374

Xwww.camlogic.it e-mail [email protected]

Page 14: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

cable terminals (Faston).Wiring with antivibrations

Standard AC1 1 vane

casing UNI5076Die-cast aluminium

Stainless steel ø10

On request power supply at 24 - 220 Va.c. 50/60Hz - And also at 24 Vd.c.

Outside casing ground

ø1"1/2 Gas

Maximum operational pressure 3 bar

Ambient temperature range -20 to +70˚C

1 -

2 -

3 -

4 -

5 -

STANDARD ASSEMBLY WITH 1"1/2 GAS THREADED NUT

B L A D E D L E V E L G A U G E P F G - 5 7

Inside casing ground

IP65 Protection

Faston

NYLON screw.

SW 55

ø34,8

23

Power supply 110 Va.c. 50/60 Hz

Weight : 1,200 Kg

NC contact 5A/250 Va.c.

Common power supply

Common contacts

NO contact 5A/250 Va.c.

Electric motor draw 4 W

WIRING

D3623

Cable inlet at 45˚

Certi

ficat

e nu

mbe

r TÜV

03

ATEX

237

4 X

SMALL-SIZED BLADED LEVEL GAUGE PARTICULARLY SUITABLE FOR USE ON SMALL TANKSOR BATCHING CELLS.

Rev. 01

20 20

267

14

100104 ø92

SW 6012

ø1"

1/2

Gas

5015

ø88

ø1/2" Gas

LEVEL GAUGESvast range, long-lasting

www.camlogic.it e-mail [email protected]

21 53 4

B 51

Page 15: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

2 ø6,5 holes

The extension can be installed at a later date

L = Length to be defined

Protection pipe ø32

Level gauge can be delivered with extension, with or without protection, the length

Model AC2 3 vane NYLON screw

is defined by the buyer during the order.

ø14

0

ø120

72

12

90

4 ø7 holes

109

45˚

19

232

8

18

10

20 20 65

2 ø6,5 holes

ø90

72

12

level gauge casing byThe flange is fixed on

at a later date.Flange can be installed

bolts assemblage.casing allows the M6x12flange and level gaugeExisting space between

for flange ø140 = ø105for flange ø105 = ø 75

on counterflange:Maximum dimension hole

Make in two versions:ø140 and ø105mm.

Die-casting aluminium

ø12

0

4 ø7 holes

ø105

two M6 screws.

flange.

Page 16: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

ø1"1/2 Gas

Stainless Steel screw.

cable terminals (Faston).Wiring with antivibrations

Standard AC1 1 vane

casing UNI5076Die-cast aluminium

Stainless steel ø10

On request power supply at 24 - 220 Va.c. 50/60Hz - And also at 24 Vd.c.

Outside casing ground

Maximum operational pressure 3 bar

Ambient temperature range -20 to +70˚C

1 -

2 -

3 -

4 -

5 -

STANDARD ASSEMBLY WITH 1"1/2 GAS THREADED SLEEVE

B L A D E D L E V E L G A U G E P F G - 5 7 / X

Inside casing ground

IP65 Protection

Faston

SW 55

ø34,8

23

Power supply 110 Va.c. 50/60 Hz

Weight : 1,200 Kg

NC contact 5A/250 Va.c.

Common power supply

Common contacts

NO contact 5A/250 Va.c.

Electric motor draw 4 W

WIRING

D3632

OF STAINLESS STEEL

THE PRODUCTS ARE MADE

PARTS IN CONTACT WITH

SLEEVE

Cable inlet at 45˚

Certi

ficat

e nu

mbe

r TÜV

03

ATEX

237

4 X

SMALL-SIZED BLADED LEVEL GAUGE PARTICULARLY SUITABLE FOR USE ON SMALL TANKSOR BATCHING CELLS.

Rev. 01

20 20

267

14

100104

5015

ø88

ø1/2" Gas

ø92

40

ø55

ø1"

1/2

Gas

LEVEL GAUGESvast range, long-lasting

www.camlogic.it e-mail [email protected]

21 53 4

B 51

Page 17: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

The extension can be installed at a later date

L = Length to be defined

Protection pipe ø30

Level gauge can be delivered with extension, with or without protection, the length

ø120

is defined by the buyer during the order.

ø14

0

90

107

17

4 ø7 holes

227

3

20 20 20 60

3mm.

four M5 screws.level gauge casing byThe flange is fixed on

at a later date.Flange can be installed

bolts assemblage.casing allows the M6x12flange and level gaugeExisting space between

Maximum dimension hole

Model AC3 4 vane Stainless steel screw

on counterflange = ø105.

Stainless steel flange.

45˚

ø10

0

Page 18: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

revolving through 360˚

Oscillating governor

Max. ø3/4" pipe

S W I N G I N G L E V E L G A U G E I L P 3

IP65 Protection

Die-cast aluminium casing UNI5076

Casing ground

10A 250V.a.c.

1 N.C. contact

2 N.O. contact

3 Com. contact

10˚

ø3/4" Gas

20˚

10˚

Faston

260

SW 36

75

105

Wiring with antivibrations cable terminals

Vertical installation maintains constant

opening measuring 80x80 mm.diameter hole or through a quadrangularAssembly is achieved by means of a 100 mm.

further used as a raceway for electrical3/4" Gas threaded coupling which can beMount by hanging through a pipe with

Ambient temperature range -10 to +80˚C

Weight : 0,800 Kg

sensitivity in all directions.

(Faston).

conductors.

ø72

ø75

D3653

60

3020

9015

LEVEL GAUGESvast range, long-lasting

www.camlogic.it e-mail [email protected]

Rev. 00

3 2 1

CLP

3

Page 19: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

Versione con prolunga

L = Lunghezza da definire

TUTTE LE PARTI A CONTATTO CON IL PRODOTTO SONO COSTRUITE IN ACCIAIO INOX

VERSIONE DI MONTAGGIO STANDARD CON MANICOTTO FILETTATO DA 1"1/2 GAS

15

acc. INOX a una aletta.Elica standard AC1 in

ø1"1/2 Gas

vasta gamma, durata elevataINDICATORI DI LIVELLO

I N D I C A T O R E D I L I V E L L O P E R A L T A T E M P E R A T U R A P F G - 5 7 / A T

Protezione IP65

di alluminio Lega UNI5076Corpo indicatore in pressofusione

Messa a terra interna

Temperatura massima 200°C

Faston

104

ø1/2"Gas

ø88

90

ø45

Messa a terra esterna

Chiave 46

ø50

ø30

20

14

23 15

342

25

20

44

ø55

ø1

"1/2

Ga

s

Aliment. a richiesta: 24-220 Vc.a. 50/60Hz

Faston antivibrazioni.Cablaggio con capicorda

In corrente continua 24 Vc.c.

Contatto di scambio N.C. 5A/250Vc.a.

Pressione massima di esercizio 1,1 bar

Alimentazione 110 Vc.a. 50/60 Hz

Temperatura di esercizio da -20 a +80°C

Contatto di scambio N.A. 5A/250Vc.a.

Assorbimento motorino 4 W

120

Peso : 1,200 Kg

Neutro alimentazione

Comune contatti

CABLAGGIO

3 -

4 -

5 -

1 -

2 -

D3662

Entrata cavi a 45°

Elica AC1/R

Inox ø10

ø42

30

15

50

155

20 100

MANICOTTO

40

ø92

Num

ero

di c

ertif

icato

TÜV

03

ATEX

237

4 X

INDICATORE DI LIVELLO AD ELICA DI RIDOTTE DIMENSIONI, PARTICOLARMENTE INDICATO PERIL MONTAGGIO SU PICCOLI SERBATOI O CELLE DI DOSATURA.

Rev. 02

www.camlogic.it e-mail [email protected]

1 42 3 5

B 51

Page 20: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

* lunghezza definibile su richiesta

pressofusione di alluminio

TUTTE LE PARTI A CONTATTO CON IL PRODOTTO SONO COSTRUITE IN ACCIAIO INOX

vasta gamma, durata elevataINDICATORI DI LIVELLO

I N D I C A T O R E D I L I V E L L O P E R A L T A T E M P E R A T U R A P F G - 5 7 / A T / F

acc. INOX a 4 alette.

Protezione IP65

Messa a terra interna

Temperatura massima 200°C

su controflangia = ø105.Dimensione foro massimo

Flangia in acciaio INOX.

Faston antivibrazioni.Cablaggio con capicorda

Faston

ø45

Elica standard AC3 in

Lega UNI5076

Corpo indicatore in

Messa a terra esterna

23 3

Aliment. a richiesta: 24-220 Vc.a. 50/60Hz

In corrente continua 24 Vc.c.

Contatto di scambio N.C. 5A/250Vc.a.

Pressione massima di esercizio 1,1 bar

Alimentazione 110 Vc.a. 50/60 Hz

Temperatura di esercizio da -20 a +80°C

Contatto di scambio N.A. 5A/250Vc.a.

Assorbimento motorino 4 W

Peso : 1,200 Kg

Neutro alimentazione

Comune contatti

CABLAGGIO

4 -

5 -

1 -

2 -

3 -

D3685

FLANGIA

Elica AC3 ø100

INOX a 4 alette

ø45

Inox ø10

Entrata cavi a 45°

Num

ero

di c

ertif

icato

TÜV

03

ATEX

237

4 X

INDICATORE DI LIVELLO AD ELICA DI RIDOTTE DIMENSIONI, PARTICOLARMENTE INDICATO PERIL MONTAGGIO SU PICCOLI SERBATOI O CELLE DI DOSATURA.

Rev. 02

ø92

104

342

20 2025

90 14 20 60

15

ø88

n.4 fori ø7ø1/2" Gas

ø140

ø120

Sp.3

147*

www.camlogic.it e-mail [email protected]

1 42 3

B 51

5

Page 21: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1 2 3

Page 22: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1 2 3

Page 23: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

16 bar

90˚C

120˚C

0,5..... 30 l/min.

SGP330 SGP331

D3339

FLOW SENSORS

Supply includes 2 m. cable with three conductors

Signal led

Brown

Blue

Black

Positive power 10-30 Vdc

Negative power 10-30 Vdc

Signal 150 mA

WIRING

SPECIFICATIONS

FLOW MEASUREMENT

F L O W S E N S O R S G P 3 3 0 - 3 3 1

Connection thread

Nominal pressure

Continuous operating temperature

Permissible peak temperature

Measurement range

Measuring accuracy

Pulse rate

Signal form

Housing

Turbine system

Sensor head

1/2"Gas female thread - double

1000 pulses/l

PNP 10..... 30 Vdc

0,5% of max. value in range 3.... 30 l/min.

Polyetherimide

Polyetherimide

Brass with chromium plating

NPN 10..... 30 Vdc

vast range, long-lasting

Rev. 01

80

40 40

1818

30

15 15

ø1/2"Gas

ø1/

2"G

as

40

6615

ø30

0,5 l/min. 1 l/min. 2 l/min. 3 l/min. 4 l/min. 5 l/min. 10 l/min.0 30

1000 pulses

800 pulses

700 pulses

500 pulses

www.camlogic.it e-mail [email protected]

Page 24: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 25: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../D

/S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8/

D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

S

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

D/S

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 26: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

G-0

5

PFG

-05/

..

1

2

3

4

5

6

7

8

9

11

10

Page 27: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../D

/S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8/

D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

S

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

D/S

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 28: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

G-0

5

PFG

-05/

..

1

2

3

4

5

6

7

8

9

11

10

Page 29: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../D

/S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8/

D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

S

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

D/S

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 30: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 31: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../D

/S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8/

D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

S

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

D/S

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 32: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 33: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

..

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../D

/S

1

2

3

4

5

6

7

8

9

10

11

PFG

-05/

../8/

D

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

S

1

2

3

4

5

6

7

8

9

10

11

R

PFG

-05/

../8/

D/S

1

2

3

4

5

6

7

8

9

11

10G-0

5

Page 34: 2 7 3 8 9 4 10 5 PFG-05/.. 11 - i-s.gr General Catalogue2010.pdf · E1-E2 E1-E2 E1-E2-E3 2 1 On Off CONDUCTIVE LEVEL CONTROLLER CLC38 D2936 IP65 Protection Stainless steel electrodes

D2933

OPERATING DISTANCE

0-25 mm.

Sensitivity

regulation trim

LED lit with

excited relay SLEEVE

Set screw dia. 5MA

Sensor area

Flexible pipe dia. 14

made of rubber-fabric

strengthened with steel

P F G 5 6 - F L C A P A C I T I V E L E V E L G A U G E

position enables the static

test on the equipment by

exciting the relay

( maximum sensitivity )

ø28

ø35

7065

135

ø2" Gas

124 ø101

ø1/

2" G

asø96

3025

100

155

55

ø67

PFG56.FL5O

1OOO

1 2 3 4 5 6 7

ALIMENTAZIONE

110 220 0....

IP65 Protection

WIRING

Common power supply

Ground

Common contacts

7 -

6 -

5 -

4 -

3 -

2 -

1 -

Power supply 110 Va.c.50/60Hz

Power supply 220 Va.c.50/60Hz

Electric draw 1 W to 220 Va.c.

Ambient temperature range -20 to +70˚C

On request power supply at 24/48 V.

Weight : 1,600 Kg

L = Length to be defined

Maximum operational pressure 8 barThe trim stop clockwise

5A.250V.a.c.

NO contact 5A/250Va.c.

NC contact 5A/250Va.c.

LEVEL GAUGESvast range, long-lasting

Rev. 00