1.Motor Starter Solution

28
MOTOR STARTER SOLUTION Radita Sonixtus Arauna

Transcript of 1.Motor Starter Solution

Page 1: 1.Motor Starter Solution

MOTOR STARTER SOLUTION

Radita Sonixtus Arauna

Page 2: 1.Motor Starter Solution

Schneider Electric 2- Marketing - Sonix

Motor Starter

●ELEKTROMEKANIK●DIRECT ON LINE● STAR DELTA●AUTO TRANSFORMER

●ELEKTRONIK● INVERTER● SOFT STARTER

Note: Pemilihan starting motor secara elektromekanik tergantung dariBESAR dan APLIKASI motor yang digunakan.

Page 3: 1.Motor Starter Solution

Schneider Electric 3- Marketing - Sonix

Direct On Line

●Current Start● 4-8x Rated Current

●Starting Torque●0.5-1.5x Rated Current

Page 4: 1.Motor Starter Solution

Schneider Electric 4- Marketing - Sonix

Direct On Line

Page 5: 1.Motor Starter Solution

Schneider Electric 5- Marketing - Sonix

Star Delta

●Current Start● 1.8-2.6x Rated Current

●Starting Torque●0.5x Rated Current

Page 6: 1.Motor Starter Solution

Schneider Electric 6- Marketing - Sonix

Star Delta

Starting time8 to 20 sec Transition

40ms

KM1 + KM2 closing

Star connection

pick-up of KM3

Delta connection

drop-out of KM1

Page 7: 1.Motor Starter Solution

Schneider Electric 7- Marketing - Sonix

Tipe Koordinasi (IEC 947-4-1)

●Tanpa Koordinasi

●Koordinasi Tipe 1

●Koordinasi Tipe 2

●Koordinasi Total

Page 8: 1.Motor Starter Solution

Schneider Electric 8- Marketing - Sonix

Tanpa Koordinasi

LC1 making/breaking capacity (IEC 947-4)

Welding curve of contacts

i

t

Starting Current

GV2 ME/RS Trip curve

Page 9: 1.Motor Starter Solution

Schneider Electric 9- Marketing - Sonix

Tanpa Koordinasi

●Jika terjadi hubung singkat● Beresiko terhadap operator dan personal● Beresiko terhadap instalasi dan peralatan

●Semua komponen motor starter harus diganti sebelum restart

Page 10: 1.Motor Starter Solution

Schneider Electric 10- Marketing - Sonix

Koordinasi Tipe 1 (IEC 947-4-1)

LC1 making/breaking capacity (IEC 947-4)

Welding curve of contacts

i

t

Starting Current

GV2 ME/RS Trip curve

Page 11: 1.Motor Starter Solution

Schneider Electric 11- Marketing - Sonix

Koordinasi Tipe 1 (IEC 947-4-1)

●Jika terjadi hubung singkat● Tidak membahayakan personal ataupun instalasi● Kontaktor dan/atau Overload Relay boleh mengalami kerusakan

●Sebelum restart, komponen motor starter harus diperbaiki

Page 12: 1.Motor Starter Solution

Schneider Electric 12- Marketing - Sonix

Koordinasi Tipe 2 (IEC 947-4-1)

LC1 making/breaking capacity (IEC 947-4)

Welding curve of contacts

i

t

Starting Current

GV2 ME/RS Trip curve

Page 13: 1.Motor Starter Solution

Schneider Electric 13- Marketing - Sonix

Koordinasi Tipe 2 (IEC 947-4-1)

●Jika terjadi hubung singkat● Tidak membahayakan personal ataupun instalasi● Tidak merusak starter● Kemungkinan kontak kontaktor meleleh dapat terjadi, akan tetapi mudah

untuk digantikan● Electrical insulation masih tetap sama, dan motor starter masih mampu

beroperasi pada tingkat hubung singkat yang sama

●Sebelum restart, pengecekan sederhana sudah mencukupi

Page 14: 1.Motor Starter Solution

Schneider Electric 14- Marketing - Sonix

Koordinasi Total (IEC 947-6-2)

Making/breaking capacity (IEC 947-6)

Never Welding

i

t

Starting Current

TeSys U Trip curve

Page 15: 1.Motor Starter Solution

Schneider Electric 15- Marketing - Sonix

Koordinasi Total (IEC 947-6-2)

●Jika terjadi hubung singkat● Tidak membahayakan personal ataupun instalasi● Tidak ada kerusakan pada starter● Tidak ada kontak kontaktor yang meleleh● Electrical insulation masih terjaga dengan baik

●Restart dapat dilakukan dengan segera

Page 16: 1.Motor Starter Solution

Schneider Electric 16- Marketing - Sonix

Pemilihan Tipe Koordinasi

Tanpa Koord. Koord. Tipe 1 Koord. Tipe 2 Koord. Total

RISK

SAFETY

COST

Page 17: 1.Motor Starter Solution

Schneider Electric 17- Marketing - Sonix

Contoh Penggunaan di Building

Air conditionning Type 1 Standard starter

Lifts / Escalators Type 2 High performance starter

Toxic fume extractor fan Total High performancecoordination starter(Tesys U)

Page 18: 1.Motor Starter Solution

Schneider Electric 18- Marketing - Sonix

Contoh Penggunaan di Industry

Packaging line Type 1 Standard starter

Bottling line Type 2 High performance starter

Petrochemical continuous Total High performanceprocess coordination starter

(Tesys U)

Page 19: 1.Motor Starter Solution

Schneider Electric 19- Marketing - Sonix

Fungsi Koordinasi dlm Motor Starter

●DISKONEKSI

●SWITCHING

●PROTEKSI SHORT CIRCUIT

●POWER CONTROL

●PROTEKSI OVER LOAD

Page 20: 1.Motor Starter Solution

Schneider Electric 20- Marketing - Sonix

Fungsi Koordinasi dlm Motor Starter

Note:

●Kesemua fungsi ini, HARUS dimiliki dalam motor starter

●Kesemua fungsi tersebut dapat dipenuhi dengan asosiasi 3 komponen, 2 komponen, atau bahkan 1 komponen

●Asosiasi / penggabungan komponen tersebut HARUS diperhatikanpemilihannya, dan diatur secara khusus oleh IEC (International Electrotechnical Commission)

Page 21: 1.Motor Starter Solution

Schneider Electric 21- Marketing - Sonix

Asosiasi 3 Komponen

Disconnection

Switching

Short Circuit Protection

Power Control

Overload Protection

Motor Circuit BreakerMotor Circuit Breaker

ContactorContactor

TORTOR

Page 22: 1.Motor Starter Solution

Schneider Electric 22- Marketing - Sonix

Asosiasi 2 Komponen

Power Control

Disconnection

Switching

Short Circuit Protection

Overload Protection

Thermal Magnetic Thermal Magnetic Motor Circuit BreakerMotor Circuit Breaker

ContactorContactor

Page 23: 1.Motor Starter Solution

Schneider Electric 23- Marketing - Sonix

Asosiasi 1 Komponen

TeSysTeSys UU

Disconnection

Switching

Short Circuit Protection

Overload Protection

Power Control

Page 24: 1.Motor Starter Solution

Schneider Electric 24- Marketing - Sonix

Kategori Utilisasi

AC 6 ?

AC 3 ?

AC 1 ?AC 4 ?

Page 25: 1.Motor Starter Solution

Schneider Electric 25- Marketing - Sonix

Kategori Utilisasi

Page 26: 1.Motor Starter Solution

Schneider Electric 26- Marketing - Sonix

Schneider Electric Motor Starter

●2 tipe starter●Standard starters (Koordinasi Tipe 1)●High performance starters (Tipe 2 & Total coordination)

●Mudah dipilih sesuai dengan peruntukan●Dengan melihat Table pada Katalog Starter

●Semua tipe standard sudah ditesting sesuai dengan IEC947 standard●3 tahun ditesting di laboratories (ASEFA, ASTA, ...)

Page 27: 1.Motor Starter Solution

Schneider Electric 27- Marketing - Sonix

Page 28: 1.Motor Starter Solution

Schneider Electric 28- Marketing - Sonix