1F82-261 / 1F89-211 TYPICAL WIRING DIAGRAMS · 1F82-261 / 1F89-211 Electric/Gas ... Reset switch...
Transcript of 1F82-261 / 1F89-211 TYPICAL WIRING DIAGRAMS · 1F82-261 / 1F89-211 Electric/Gas ... Reset switch...
L RE
24 VAC 120 VAC
Hot
SYSTEMMONITORSWITCH
Neutral
SYSTEMG W2
Single transformer systems
TRANSFORMER
(Class II)
ChangeoverRelay*
CYO/B
CompressorContactor
* Changeover Relay is energized in COOL when O/B switch is in the “O” positionChangeover Relay is energized in HEAT when O/B switch is in the “B” position
AuxRelay
(Stage 2)
FanRelay
EmergencyRelay
See Note **
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
L RE
24 VAC 120 VAC
Hot
SYSTEMMONITORSWITCH
Neutral
SYSTEMG W2
Two transformer systems with NO safety circuits
TRANSFORMER
(Class II)
ChangeoverRelay*
CYO/B
CompressorContactor
* Changeover Relay is energized in COOL when O/B switch is in the “O” positionChangeover Relay is energized in HEAT when O/B switch is in the “B” position
AuxRelay
(Stage 2)
FanRelay Emergency
Relay
Limit orSafety
Switches
TWO COMMONS MUSTBE JUMPERED TOGETHER!
HOT
NEUTRAL
120 VAC 24 VAC
CUT ANDTAPE OFF!
If safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits.
NOTE
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
See Note **
1F82-261 / 1F89-211
Electric/Gasjumper (W904)
O/Bswitch
Reset switch(below Fan switch)
W904
The following table allows you to customize the options on your Comfort-Set thermostat. Begin by pressing simultaneously the two buttons in step 1.
Electric / Gas Jumper (Fan Option)If your emergency or auxiliary system will energize the blower, then jumperW904,onthethermostatbase,mustbecut(seefigureatleft).Ifyouremergencyorauxiliaryheatsystemrequiresthatthethermostatenergizethefancircuit,donotcutjumperW904.
O/B Terminal Switch SelectionThe O/B switch on this thermostat is factory set to the “O” position. Thiswillaccommodatethemajorityofheatpumpapplications,whichrequirethechangeoverrelaytobeenergizedinCOOL.Ifthether-mostat you are replacing or the heat pump being installed with this thermostatrequiresa“B”terminal,toenergizethechangeoverrelayin HEAT, the O/B switch must be moved to the “B” position.
CONFIGURATION ANDTYPICAL WIRING DIAGRAMS
CONFIGURATION
TYPICAL WIRING DIAGRAMS
1
Displayed (Factory Default) Press or to select: COMMENTS
HOLD(0:00)
0 to 8 hrs (in 15 minute increments)
2(SL)
FA
Select temporary Hold time
5
6
E(on)
OFF
7
8
LOC(OFF)
on
0 HI(0)
4 LO to4 HI
°(F) °C
Returns to normal operation
9
11
Select Energy Management Recovery OFF or ON
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to °F or °C
Set SYSTEMswitch to OFF
or
4 d-L(on)
OFF Select display backlight OFF or ON
Filter(000)
0 to 1950 hours(in 50 hour increments)
Select filter replacement run time
Select FA or SL (Fast or Slow) pump cycle rate
Configuration Menu
* Press HOLD to advance to next item or TIME to move backwards to previous item
3 EMER(FA)
SL Select FA or SL (Fast or Slow) Auxiliary and Emergency Aux heating cycle rate
1F89-211Press Button(s)Step
RUN
PRGMand RUN
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
HOLD*
1F82-261Press Button(s)
or
or
or
or
or
or
or
HOLD*
FA (ON) OFF10 Selects fast second stage ON or OFFHOLD* or
www.white-rodgers.com158
TEC
HN
ICA