The Guide Right Surgical Guide System is a system of components for the fabrication and correction of diagnostic and surgical dental implant guides in 1 or 2 dimensions.

Transcript of 19 fibular graft case

Page 1: 19 fibular graft case

# 29 and #30

3 mm Guide Posts

3 mm Diagnostic Guide Sleeves

3 mm Magnetic Guide Posts

3.3 and 4 mm Open Guide Sleeves

Generation ll / Guide Post Bending Tool

Software Evaluation

Guide Right™

Fibular Graft Case

Invivo5 Anatomage

Featuring:

KARLS

Page 2: 19 fibular graft case

This patient had a section of the mandible removed & grafted

with a vascular fibular graft 2 years prior to implant placement.

Page 3: 19 fibular graft case

Fabrication of DIAGNOSTIC Guide

Page 4: 19 fibular graft case

3/32” holes were drilled in the cast in the positions of the 2nd bicuspid and 1st molar.

The cast was lubricated with petroleum jelly.

Two straight 3 mm guide posts were placed in the openings.

Page 5: 19 fibular graft case

3 mm cylindrical guide sleeves were placed on the guide posts

with cleats positioned toward the lingual surface.

Page 6: 19 fibular graft case

Triad® Gel was added & cured to capture the cleats& form the DIAGNOSTIC

guide which was placed in the patient and a cone beam X-ray was taken.

Page 7: 19 fibular graft case

Invivo5

Software Evaluation

Pre-op

Anatomage

Page 8: 19 fibular graft case

The DIAGNAOSTIC guide sleeves viewed in the cone beam images were evaluated.

[ axial, tangential and cross sectional views ]

axial cross sectional

tangential volumetric

Invivo5 Anatomage

# 29

Initial Alignment

Page 9: 19 fibular graft case

# 29

8° angular correction to the mesial is necessary

axial cross sectional

tangential volumetric

Invivo5 Anatomage

Page 10: 19 fibular graft case

# 29

▪ close-up showing 8° bend toward the mesial needed ▪

tangential

Invivo5 Anatomage

Page 11: 19 fibular graft case

axial cross sectional

tangential volumetric

# 29

ANGULAR CORRECTION: 5 ° toward the lingual

LINEAR CORRECTION: 1 mm offset

Invivo5 Anatomage

Page 12: 19 fibular graft case

5° angular correction 1 mm offset linear correction

cross section tangential # 29

Invivo5 Anatomage

Page 13: 19 fibular graft case

axial cross sectional

tangential volumetric

# 30

Initial Alignment

Invivo5 Anatomage

Invivo5 Anatomage

Page 14: 19 fibular graft case

cross sectional

# 30

Shows initial alignment is NOT GOOD

Invivo5 Anatomage

cross sectional view

Page 15: 19 fibular graft case

axial cross sectional

tangential volumetric

# 30

4.8 mm X 10 mm Straumann Implant (virtual image)

1 mm offset guide post > 15° bend toward lingual

Invivo5 Anatomage

Page 16: 19 fibular graft case

cross sectional

shows a 15° angular correction is necessary for the

guide sleeve to line up with the position of the virtual implant

Invivo5 Anatomage

tangential view

# 30

Page 17: 19 fibular graft case

Guide Right™

Generation ll ▪ Guide Post Bending Tool

For more information on use of the bending tool go to

www.deplaque.com ▪ Guide Right™ Generation ll Bending Tool

10 ° example

Page 18: 19 fibular graft case

Preview of Pre-op Corrections

#30

LINEAR CORRECTION

1 mm offset

ANGULAR CORRECTION

1 BEND: 15° toward lingual

#29

LINEAR CORRECTION

1 mm offset

ANGULAR CORRECTION

1ST BEND: 8° toward the mesial

2nd BEND: 5° toward the lingual

Cosine is applied to determine correction data.

* see next 3 slide

Page 19: 19 fibular graft case

Guide post positioned in the bending tool

with offset positioned forward.

# 29

Page 20: 19 fibular graft case

BEND

8° toward the mesial

# 29

Page 21: 19 fibular graft case

The 1 mm offset guide post with an 8 mm correction is rotated 90°

and placed back in the bending tool for the second 5° bend toward lingual.

Page 22: 19 fibular graft case

# 29 5° correction

Page 23: 19 fibular graft case

stylus over 1 mm offset guide post bent 15° toward lingual

# 30

Page 24: 19 fibular graft case

# 29 1 mm offset

5 ° bend

# 29

8° lingual bend

tangential view cross sectional view

Page 25: 19 fibular graft case

Offset magnetic guide posts in cast

Page 26: 19 fibular graft case

Buccal view of magnetic guide post with open guide sleeve

Page 27: 19 fibular graft case

Fabrication of SURGICAL Guide

Page 28: 19 fibular graft case

Triad® Gel added to open guide sleeves to form the SURGICAL guide.

Page 29: 19 fibular graft case

SURGICAL Guide

Page 30: 19 fibular graft case

Ramus plate must be avoided

Page 31: 19 fibular graft case

Invivo5

Software Verification

Post-op

Anatomage

Page 32: 19 fibular graft case

axial cross sectional

tangential volumetric

#29

Note: implant placement

with virtual implants positioned over actual implants

Invivo5 Anatomage

Page 33: 19 fibular graft case

axial cross sectional

tangential volumetric

#30

Post-op Implant Placement

Invivo5 Anatomage

Page 34: 19 fibular graft case

Custom impression coping due to the depth of the fixture

Page 35: 19 fibular graft case

Peri-apical X-ray to confirm seating of impression coping.

Page 36: 19 fibular graft case

Custom Atlantis Abutments

Page 37: 19 fibular graft case

Final restoration in master cast

Page 38: 19 fibular graft case

Restoration on master cast

Page 39: 19 fibular graft case

Atlantis Abutments in place

Page 40: 19 fibular graft case

Final restoration

Page 41: 19 fibular graft case

Magnetic Offset Guide Posts

Straight

3.0 mm od

Offset

3.0 od X 0.5 mm os

3.0 od X 1.0 mm os

3.0 od X 1.5 mm os

3.0 od X 2.0 mm os

3.0 od X 2.5 mm os

3.0 od X 3.0 mm os

Page 42: 19 fibular graft case

Guide Right™

Products shown in this case

3/32” Drill

3 mm Guide Posts

3 mm Diagnostic Guide Sleeves

3 mm Magnetic guide posts

3.3 mm Open Guide sleeves

4 mm Open Guide Sleeves

1.0 mm Offset Magnetic Guide Sleeve

Triad® Gel

1.800.314.0065 • www.deplaque.com

Page 43: 19 fibular graft case

Guide Right™ Surgical Guide System

Start With Precision. Place With Confidence.™

1.800.314.0065 • www.deplaque.com

fabricate ▪ evaluate ▪ correct ▪ verify ▪ place

DéPlaque