Portable Air Compressor 185 Tier 4 Final Kubota PART NUMBER: 02250216-781 R01 The information in this manual is current as of its publication date and applies to compressor models indicated on this cover with serial number: 201507170000 and all subsequent serial numbers. USER MANUAL Publication date: 4/13/2016 Copyright © 2015 – 2016 Sullair, LLC. All rights reserved. WARRANTY NOTICE Failure to follow the instructions and procedures in this manual, or misuse of this equipment, will void its warranty. Subject to EAR, ECCN EAR99 and related export control restrictions. SAFETY WARNING Users are required to read the entire User Manual before han- dling or using the product.

Transcript of 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation...

Page 1: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Portable Air Compressor185

Tier 4 FinalKubota

PART NUMBER:02250216-781 R01

The information in this manual is current as of its publication date and applies to compressor models indicated on this cover with serial number:

201507170000and all subsequent serial numbers.

USER MANUAL

Publication date: 4/13/2016Copyright © 2015 – 2016 Sullair, LLC. All rights reserved.

WARRANTY NOTICE

Failure to follow the instructions and procedures in this manual, or misuse of this equipment, will void its warranty.

Subject to EAR, ECCN EAR99 and related export control restrictions.

SAFETY WARNING

Users are required to read the entire User Manual before han-dling or using the product.

Page 2: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Air Care Seminar Training

Sullair Air Care Seminars are courses that provide hands-on instruction for the proper operation, maintenance, and servicing of Sullair products. Individual seminars on Portable compressors are offered at regular intervals throughout the year at Sullair’s training facility located in Michigan City, Indiana.

Instruction includes training on the function and installation of Sullair service parts, troubleshooting common faults and malfunctions, and actual equipment operation. These seminars are recommended for maintenance, contractor maintenance, and service personnel.

For detailed course outlines, schedule, and cost information contact:

Sullair Training Department

1-888-SULLAIR or219-879-5451 (ext. 5623)

[email protected]

- Or Write -

Sullair, LLC3700 E. Michigan Blvd.Michigan City, IN 46360

Attn: Service Training Department.

Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 3: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Table of Contents

185 T4F Kubota User Manual Table of Contents

Section 1: Safety.......................................................................................................1

1.1 General....................................................................................................... 11.2 Personal protective equipment ................................................................... 11.3 Pressure release ........................................................................................ 11.4 Fire and explosion ...................................................................................... 21.5 Moving parts ............................................................................................... 31.6 Hot surfaces, sharp edges and sharp corners............................................ 4

1.6.1 Tier 4 emissions module—if equipped...................................................................4

1.7 Toxic and irritating substances................................................................... 41.8 Electrical shock........................................................................................... 51.9 Lifting .......................................................................................................... 61.10 Entrapment ................................................................................................. 61.11 Implementation of lockout/tagout................................................................ 61.12 Jump starting.............................................................................................. 71.13 Towing1...................................................................................................... 8

1.13.1 Preparing to tow.....................................................................................................8

1.13.2 Towing .................................................................................................................10

1.13.3 Parking or locating compressor ...........................................................................10

1.14 California proposition 65........................................................................... 111.15 Symbols and references........................................................................... 12

Section 2: Description............................................................................................17

2.1 Introduction............................................................................................... 172.2 Description of components ....................................................................... 172.3 Sullair compressor unit, functional description ......................................... 172.4 Compressor cooling and lubrication system, functional description ......... 172.5 Compressor discharge system, functional description ............................. 192.6 Capacity control system, functional description........................................ 20

2.6.1 Start—0 to 58 psig (0 to 4.0 bar) .........................................................................21

2.6.2 Normal operation—80 to 100 psig (5.6 to 6.9 bar) ..............................................21

2.6.3 Modulation—100 to 125 psig (6.9 to 8.6 bar) ......................................................21

2.6.4 Shutdown.............................................................................................................21

2.7 Piping and instrumentation—compressor system .................................... 222.8 Piping and instrumentation—engine system ............................................ 24

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. i

Page 4: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Table of Contents 185 T4F Kubota User Manual

2.9 Air inlet system, functional description......................................................262.10 Instrument panel group, functional description .........................................262.11 Engine exhaust after-treatment.................................................................282.12 Wiring diagram..........................................................................................302.13 Electrical system, functional description ...................................................32

Section 3: Specifications....................................................................................... 33

3.1 Specifications—49HP 185 Kubota............................................................333.2 Lubrication guide—compressor ................................................................343.3 Lubrication guide—engine ........................................................................343.4 Application guide.......................................................................................353.5 Identification—DPQ ..................................................................................363.6 Identification—DLQ...................................................................................38

Section 4: Operation .............................................................................................. 41

4.1 General .....................................................................................................414.2 Purpose of controls ...................................................................................414.3 Starting the compressor............................................................................414.4 Shutting down the compressor .................................................................424.5 Troubleshooting ........................................................................................43

Section 5: Maintenance ......................................................................................... 47

5.1 General .....................................................................................................475.2 Engine coolant requirement for radiators..................................................475.3 Daily maintenance ....................................................................................475.4 Maintenance after initial 50 hours of operation .........................................475.5 Maintenance every 50 hours.....................................................................485.6 Maintenance every 100 hours...................................................................485.7 Maintenance every 250 hours...................................................................485.8 Maintenance every 1500 hours.................................................................485.9 Part replacement and adjustment procedures ..........................................48

5.9.1 Compressor fluid change procedure ................................................................... 48

5.9.2 Compressor fluid filter replacement .................................................................... 48

5.9.3 Air filter maintenance .......................................................................................... 48

5.9.4 Separator element replacement.......................................................................... 49

5.9.5 Fuel/water separator maintenance...................................................................... 50

5.9.6 Cleaning the engine cooling system ................................................................... 51

5.9.7 Procedure for setting speed & pressure controls on portable compressors equipped with poppet valves............................................................................... 52

5.9.8 Bearing lubrication .............................................................................................. 53

5.10 Troubleshooting ........................................................................................54

02250216-781 R01ii Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 5: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual Table of Contents

Section 6: Noise Control........................................................................................57

6.1 Noise emissions warranty......................................................................... 576.2 Tampering with the noise control system is prohibited............................. 576.3 Noise emissions maintenance and maintenance record log .................... 58

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. iii

Page 6: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Table of Contents 185 T4F Kubota User Manual

Notes:

02250216-781 R01iv Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 7: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Section 1

185 T4F Kubota User Manual 1: Safety

Safety

1.1 GeneralSullair designs and manufactures all of its products so they can be operated safely. However, the responsibility for safe operation rests with those who use and maintain these products. The following safety precautions are offered as a guide which, if conscientiously followed, will minimize the possibility of accidents throughout the use-ful life of this equipment. Read the AEM Safety Manual prior to compressor operation and towing, if applica-ble in your area.

The air compressor should be operated only by those who have been trained and delegated to do so, and who have read and understood this Operator’s Manual. Fail-ure to follow the instructions, procedures and safety pre-cautions in this manual can result in accidents and injuries.

NEVER start the air compressor unless it is safe to do so. DO NOT attempt to operate the air compressor with a known unsafe condition. Tag the air compressor and ren-der it inoperative by disconnecting and locking out all power at source or otherwise disabling its prime mover so others who may not know of the unsafe condition can-not attempt to operate it until the condition is corrected.

Use and operate the air compressor only in full compli-ance with all pertinent OSHA requirements and/or all per-tinent Federal, State and Local codes or requirements.

DO NOT modify the compressor except with written fac-tory approval.

Each day, walk around the air compressor and inspect for leaks, loose or missing parts, damaged parts or parts out of adjustment. Perform all recommended daily mainte-nance.

Inspect for torn, frayed, blistered or otherwise deterio-rated and degraded hoses. Replace as required.

1.2 Personal protective equipmentA. Prior to installing or operating the compressor, own-

ers, employers and users should become familiar with, and comply with, all applicable OSHA regula-tions and/or any applicable Federal, State and Local codes, standards, and regulations relative to per-sonal protective equipment, such as eye and face protective equipment, respiratory protective equip-ment, equipment intended to protect the extremities, protective clothing, protective shields and barriers and electrical protective equipment, as well as noise exposure administrative and/or engineering controls and/or personal hearing protective equipment.

1.3 Pressure release A. Open the pressure relief valve at least weekly to

make sure it is not blocked, closed, obstructed or otherwise disabled.

B. Install an appropriate flow-limiting valve between the compressor service air outlet and the shutoff (throt-tle) valve, when an air hose exceeding 1/2″ (13 mm) inside diameter is to be connected to the shutoff (throttle) valve, to reduce pressure in case of hose failure, per OSHA Standard 29 CFR 1926.302 (b) (7) or any applicable Federal, State and Local codes, standards and regulations.

C. When the hose is to be used to supply a manifold, install an additional appropriate flow-limiting valve between the manifold and each air hose exceeding 1/2″ (13 mm) inside diameter that is to be connected to the manifold to reduce pressure in case of hose failure.

NOTE

Operator is required to readentire instruction manual.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 1

Page 8: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

D. Provide an appropriate flow-limiting valve for each additional 75 feet (23 m) of hose in runs of air hose exceeding 1/2″ (13 mm) inside diameter to reduce pressure in case of hose failure.

E. Flow-limiting valves are listed by pipe size and rated CFM. Select appropriate valve accordingly.

F. DO NOT use tools that are rated below the maximum rating of this compressor. Select tools, air hoses, pipes, valves, filters and other fittings accordingly. DO NOT exceed manufacturer’s rated safe operating pressures for these items.

G. Secure all hose connections by wire, chain or other suitable retaining device to prevent tools or hose ends from being accidentally disconnected and expelled.

H. Open fluid filler cap only when compressor is not run-ning and is not pressurized. Shut down the compres-sor and bleed the sump (receiver) to zero internal pressure before removing the cap.

I. Vent all internal pressure prior to opening any line, fit-ting, hose, valve, drain plug, connection or other component, such as filters and line oilers, and before attempting to refill optional air line anti-icer systems with antifreeze compound.

J. Keep personnel out of line with and away from the discharge opening of hoses, tools or other points of compressed air discharge.

K. DO NOT use air at pressures higher than 30 psig (2.1 bar) for cleaning purposes, and then only with effective chip guarding and personal protective equipment per OSHA Standard 29 CFR 1910.242 (b) or any applicable Federal, State and Local codes, standards and regulations.

L. DO NOT engage in horseplay with air hoses as death or serious injury may result.

M. This equipment is supplied with an ASME designed pressure vessel protected by an ASME rated relief valve. Lift the handle once a week to make sure the valve is functional. DO NOT lift the handle while machine is under pressure.

N. If the machine is installed in an enclosed area it is necessary to vent the relief valve to the outside of the structure or to an area of non-exposure.

O. DO NOT remove radiator filler cap until the coolant temperature is below its boiling point. Then loosen cap slowly to its stop to relieve any excess pressure and make sure coolant is not boiling before removing

cap completely. Remove radiator filler cap only when cool enough to touch with a bare hand.

P. The ethyl ether in the replaceable cylinders used in diesel ether starting aid systems (optional) is under pressure. DO NOT puncture or incinerate those cyl-inders. DO NOT attempt to remove the center valve core or side pressure relief valve from these cylin-ders regardless of whether they are full or empty.

Q. If a manual blowdown valve is provided on the receiver, open the valve to ensure all internal pres-sure has been vented prior to servicing any pressur-ized component of the compressor air/fluid system.

1.4 Fire and explosion

A. Refuel at a service station or from a fuel tank designed for its intended purpose. If this is not possi-ble, ground the compressor to the dispenser prior to refueling.

B. Clean up spills of lubricant or other combustible sub-stances immediately, if such spills occur.

C. Shut off air compressor and allow it to cool. Then keep sparks, flames and other sources of ignition away and DO NOT permit smoking in the vicinity when adding fuel, checking or adding electrolyte to batteries, checking or adding fluid, checking diesel engine ether starting aid systems, replacing cylin-ders, or when refilling air line anti-icer systems anti-freeze compound.

D. DO NOT permit fluids, including air line anti-icer sys-tem antifreeze compound or fluid film, to accumulate on, under or around acoustical material, or on any external surfaces of the air compressor. Wipe down using an aqueous industrial cleaner or steam clean as required. If necessary, remove acoustical mate-rial, clean all surfaces and then replace acoustical material. Any acoustical material with a protective covering that has been torn or punctured should be replaced immediately to prevent accumulation of liq-

WARNING

Do not attempt to operate the compressor in any classification of hazardous environment or potentially explosive atmosphere unless the compressor has been specially designed and manufactured for that duty.

02250216-781 R012 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 9: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 1: Safety

uids or fluid film within the material. DO NOT use flammable solvents for cleaning purposes.

E. Disconnect and lock out all power at source prior to attempting any repairs or cleaning of the compressor or of the inside of the enclosure, if any.

F. Keep electrical wiring, including all terminals and pressure connectors in good condition. Replace any wiring that has cracked, cut, abraded or otherwise degraded insulation, or terminals that are worn, dis-colored or corroded. Keep all terminals and pressure connectors clean and tight.

G. Turn off battery charger before making or breaking connections to the battery.

H. Keep grounded and/or conductive objects such as tools away from exposed live electrical parts such as terminals to avoid arcing which might serve as a source of ignition.

I. Replace damaged fuel tanks or lines immediately rather than attempt to weld or otherwise repair them. DO NOT store or attempt to operate the compressor with any known leaks in the fuel system. Tag the compressor and render it inoperative until repair can be made.

J. Remove any acoustical material or other material that may be damaged by heat or that may support combustion and is in close proximity, prior to attempt-ing weld repairs.

K. Keep suitable fully charged Class BC or ABC fire extinguisher or extinguishers nearby when servicing and operating the compressor.

L. Keep oily rags, trash, leaves, litter or other combusti-bles out of and away from the compressor.

M. Open all access doors and allow the enclosure to ventilate thoroughly prior to attempting to start the engine.

N. DO NOT operate compressor under low overhanging leaves or permit such leaves to contact hot exhaust system surfaces when operating the compressor in forested areas.

O. Ethyl ether used in diesel engine ether starting aid systems is extremely flammable. Change cylinders, or maintain or troubleshoot these systems only in well-ventilated areas away from heat, open flame or sparks. DO NOT install, store or otherwise expose ether cylinders to temperatures above 160°F (71°C). Remove ether cylinder from the compressor when operating in ambient temperatures above 60°F (16°C).

P. DO NOT attempt to use ether as a starting aid in gas-oline engines or diesel engines with glow plugs as serious personnel injury or property damage may result.

Q. DO NOT spray ether into compressor air filter or into an air filter that serves both the engine and the com-pressor as serious damage to the compressor or per-sonal injury may result.

R. Antifreeze compound used in air line anti-icer sys-tems contains methanol which is flammable. Use systems and refill with compound only in well-venti-lated areas away from heat, open flames or sparks. DO NOT expose any part of these systems or the antifreeze compound to temperatures above 150°F (66°C). Vapors from the antifreeze compound are heavier than air. DO NOT store compound or dis-charge treated air in confined or unventilated areas. DO NOT store containers of antifreeze compound in direct sunlight.

S. Store flammable fluids and materials away from your work area. Know where fire extinguishers are and how to use them, and for what type of fire they are intended. Check readiness of fire suppression sys-tems and detectors if so equipped.

T. DO NOT operate the compressor without proper flow of cooling air or water or with inadequate flow of lubri-cant or with degraded lubricant.

U. DO NOT attempt to operate the compressor in any classification of hazardous environment unless the compressor has been specially designed and manu-factured for that duty.

1.5 Moving parts

A. Keep hands, arms and other parts of the body and also clothing away from couplings, fans and other moving parts.

B. DO NOT attempt to operate the compressor with the fan, coupling or other guards removed.

WARNING

Disconnect and lock out all power at source and verify at the compressor that all circuits are de-energized to minimize the possibility of acciden-tal start-up, or operation, prior to attempting repairs or adjustments. This is especially impor-tant when compressors are remotely controlled.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 3

Page 10: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

C. Wear snug-fitting clothing and confine long hair when working around this compressor, especially when exposed to hot or moving parts.

D. Make sure all personnel are out of and/or clear of the compressor prior to attempting to start or operate it.

E. When adjusting the controls, it may require operation of the equipment during adjustment. DO NOT come in contact with any moving parts while adjusting the control regulator and setting the engine RPM. Make all other adjustments with the engine shut off. When necessary, make adjustment, other than setting con-trol regulator and engine RPM, with the engine shut off. If necessary, start the engine and check adjust-ment. If adjustment is incorrect, shut engine off, read-just, then restart the engine to recheck adjustment.

F. Keep hands, feet, floors, controls and walking sur-faces clean and free of fluid, water or other liquids to minimize the possibility of slips and falls.

1.6 Hot surfaces, sharp edges and sharp corners

A. Avoid bodily contact with hot fluid, hot coolant, hot surfaces and sharp edges and corners.

B. Keep all parts of the body away from all points of air discharge and away from hot exhaust gases.

C. Wear personal protective equipment including gloves and head covering when working in, on or around the compressor.

D. Keep a first aid kit handy. Seek medical assistance promptly in case of injury. DO NOT ignore small cuts and burns as they may lead to infection.

1.6.1 Tier 4 emissions module—if equipped

General Guidelines: Thermal Protection. The main exhaust piping routes exhaust gas from the engine to the exhaust aftertreatment. Normal operating temperatures can reach up to 530°C (986°F). Regeneration of the Die-sel Particulate Filter (DPF) can create temperatures above normal engine exhaust temperatures. Gas tem-peratures during the regeneration period can reach 750°C (1382°F).

1.7 Toxic and irritating substancesA. DO NOT use air from this compressor for respiration

(breathing) except in full compliance with OSHA Standards 29 CFR 1920 and any other Federal, State or Local codes or regulations.

T4—WARNING

Increased DPF skin temperature and exhaust gas temperature may occur in the event of an unexpected engine/aftertreatment failure. An unexpected failure of the engine/aftertreatment may increase temperature at the DPF as high as 900°C (1652°F) gas temperature and 750°C (1382°F) skin temperature. This may result in fire, burn, or explosion hazards, which may result in personal injury or death. Do not expose flammable material or explosive atmospheres to exhaust gas or exhaust system components dur-ing regeneration. The aftertreatment skin tem-perature and the gas temperature are difficult to measure and/or simulate and are dependent upon many factors including the following: the nature of the engine/aftertreatment failure, the design and packaging of the aftertreatment, the engine speed/load conditions, the condition of the aftertreatment and ambient conditions. Therefore, the potential temperatures are pro-vided as a guideline even under conditions of unexpected engine and/or aftertreatment failure.

DANGER

Death or serious injury can result from inhaling compressed air without using proper safety equipment. See OSHA standards and/or any applicable Federal, State, and Local codes, stan-dards and regulations on safety equipment.

02250216-781 R014 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 11: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 1: Safety

B. DO NOT use air line anti-icer systems in air lines supplying respirators or other breathing air utilization equipment and DO NOT discharge air from these systems into unventilated or other confined areas.

C. Operate the compressor only in open or adequately ventilated areas.

D. Locate the compressor so that exhaust fumes are not apt to be carried towards personnel, air intakes ser-vicing personnel areas or towards the air intake of any portable or stationary compressor.

E. Fuels, fluids and lubricants used in this compressor are typical of the industry. Care should be taken to avoid accidental ingestion and/or skin contact. In the event of ingestion, seek medical treatment promptly. Wash with soap and water in the event of skin con-tact. Consult Material Safety Data Sheet for informa-tion pertaining to the specific fluid.

F. Wear goggles or a full face shield when adding anti-freeze compound to air line anti-icer systems.

G. Wear an acid-resistant apron and a face shield or goggles when servicing the battery. If electrolyte is spilled on skin or clothing, immediately flush with large quantities of water.

H. Ethyl ether used in diesel engine ether starting aid systems is toxic, harmful or fatal if swallowed. Avoid contact with the skin or eyes and avoid breathing the fumes. If swallowed, DO NOT induce vomiting and call a physician immediately.

I. Wear goggles or a full face shield when testing ether starting aid systems or when adding antifreeze com-pound to air line anti-icer systems. Keep openings of valve or atomizer tube of ether starting aid system pointed away from yourself and other personnel.

J. If air line anti-icer system antifreeze compound enters the eyes or if fumes irritate the eyes, they should be washed with large quantities of clean water for fifteen minutes. A physician, preferably an eye specialist, should be contacted immediately.

K. DO NOT store ether cylinders or air line anti-icer sys-tem antifreeze compound in operator’s cabs or in other similar confined areas.

L. The antifreeze compound used in air line antifreeze systems contains methanol and is toxic, harmful or fatal if swallowed. Avoid contact with the skin or eyes and avoid breathing the fumes. If swallowed, induce vomiting by administering a tablespoon of salt, in each glass of clean, warm water until vomit is clear, then administer two teaspoons of baking soda in a

glass of clean water. Have patient lay down and cover eyes to exclude light. Call a physician immedi-ately.

M. If your compressor is equipped with Diesel Emis-sions Fluid (DEF), when handling DEF wear protec-tive clothing. Tools and clothing that come in contact with DEF must be cleaned.

1.8 Electrical shockA. Keep the towing vehicle or equipment carrier, com-

pressor hoses, tools and all personnel at least 10 feet (3 m) from power lines and buried cables.

B. Stay clear of the compressor during electrical storms! It can attract lightning.

C. Keep all parts of the body and any hand-held tools or other conductive objects away from exposed live parts of electrical system. Maintain dry footing, stand on insulating surfaces and DO NOT contact any other portion of the compressor when making adjust-ments or repairs to exposed live parts of the electrical system.

D. Attempt repairs in clean, dry and well lighted and ventilated areas only.

IMPORTANT

It is very important that all electrical connectors are protected from coming in contact with DEF. If not, there is a risk that DEF will cause oxidation in the wiring that is not possible to clean. The resulting oxidation will result in a wiring/connec-tion failure. Water and compressed air fail to remove DEF. If a connector has been in contact with DEF, it must be changed immediately to prevent the chemical from further migrating into the wiring cable harness, which happens at a speed of 0.6 m/h.

WARNING

In case of DEF contact with eyes or skin, the affected area must be thoroughly rinsed with lukewarm water. If you breathe any fumes, make sure and breathe fresh air.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 5

Page 12: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

1.9 LiftingA. If the compressor is provided with a lifting bail, then

lift by the bail provided. If no bail is provided, then lift by sling. Compressors to be air lifted by helicopter must not be supported by the lifting bail, but by slings instead. In any event, lift only in full compliance with OSHA Standards 29 CFR 1910 subpart N or any other Local, State, Military and Federal regulations that may apply.

B. Inspect lifting bail and points of attachment for cracked welds and for cracked, bent, corroded or otherwise degraded members and for loose bolts or nuts prior to lifting.

C. Make sure entire lifting, rigging and supporting struc-ture has been inspected, is in good condition and has a rated capacity of at least the net weight of the com-pressor plus an additional 10% allowance for weight of water, snow, ice, mud, stored tools, and equip-ment. If your are unsure of the weight, then weigh compressor before lifting.

D. Make sure lifting hook has a functional safety latch or equivalent, and is fully engaged and latched on the bail.

E. Use guide ropes or equivalent to prevent twisting or swinging of the compressor once it has been lifted clear of the ground.

F. DO NOT attempt to lift in high winds.

G. Keep all personnel out from under and away from the compressor whenever it is suspended.

H. Lift compressor no higher than necessary.

I. Keep lift operator in constant attendance whenever compressor is suspended.

J. Set compressor down only on a level surface capa-ble of supporting at least its net weight plus an addi-tional 10% allowance for the weight of water, snow, ice, mud, stored tools, and/or equipment.

K. If the compressor is provided with parking brakes, make sure they are set, and in any event, block or chock both sides of all running wheels before disen-gaging the lifting hook.

1.10 EntrapmentA. Make sure all personnel are out of compressor

before closing and engaging enclosure doors.

B. If the compressor is large enough to hold a man and if it is necessary to enter it to perform service adjust-

ments, inform other personnel before doing so, or else secure the access door in the open position to avoid the possibility of others closing and possibly latching the door with personnel inside.

1.11 Implementation of lockout/tagoutThe energy control procedure defines actions necessary to lockout a power source of any machine to be repaired, serviced or set-up, where unexpected motion, or an elec-trical or other energy source, would cause personal injury or equipment damage. The power source on any machine shall be locked out by each employee doing the work except when motion is necessary during setup, adjustment or trouble-shooting.

A. The established procedures for the application of energy control shall cover the following elements and actions and shall be initiated only by Authorized Per-sons and done in the following sequence:

1. Review the equipment or machine to be locked and tagged out.

2. Alert operator and supervisor of which machine is to be worked on, and that power and utilities will be turned off.

3. Check to make certain no one is operating the machine before turning off the power.

4. Turn off the equipment using normal shut-down procedure.

5. Disconnect the energy sources:

a. Air and hydraulic lines should be bled, drained and cleaned out. There should be no pressure in these lines or in the reservoir tanks. Lockout or tag lines or valves.

b. Any mechanism under tension or pres-sure, such as springs, should be released and locked out or tagged.

c. Block any load or machine part prior to working under it.

d. Electrical circuits should be checked with calibrated electrical testing equipment and stored energy and electrical capaci-tors should be safely discharged.

6. Lockout and/or Tagout each energy source using the proper energy isolating devices and tags. Place lockout hasp and padlock or tag at the point of power disconnect where lockout is required by each person perform-ing work. Each person shall be provided with their own padlock and have possession of

02250216-781 R016 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 13: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 1: Safety

the only key. If more than one person is working on a machine each person shall affix personal lock and tag using a multi-lock device.

7. Tagout devices shall be used only when power sources are not capable of being locked out by use of padlocks and lockout hasp devices. The name of the person affix-ing tag to power source must be on tag along with date tag was placed on power source.

8. Release stored energy and bring the equip-ment to a “zero mechanical state”.

9. Verify Isolation: Before work is started, test equipment to ensure power is disconnected.

B. General Security

1. The lock shall be removed by the “Autho-rized” person who put the lock on the energy-isolating device. No one other than the person/persons placing padlocks and lockout hasps on power shall remove pad-lock and lockout hasps and restore power. However, when the authorized person who applied the lock is unavailable to remove it his/her Supervisor may remove padlock/pad-locks and lockout hasps and restore power only if it is first:

a. verified that no person will be exposed to danger.

b. verified that the “Authorized” person who applied the device is not in the facility.

c. noted that all reasonable efforts to con-tact the “Authorized” person have been made to inform him or her that the lock-out or tagout device has been removed.

d. ensured that the “Authorized” person is notified of lock removal before returning to work.

2. Tagout System—Tags are warning devices affixed at points of power disconnect and are not to be removed by anyone other that the person placing tag on power lockout. Tags shall never be by-passed, ignored, or other-wise defeated.

1.12 Jump startingA. Observe all safety precautions mentioned elsewhere

in this manual.

B. Batteries may contain hydrogen gas which is flam-mable and explosive. Keep flames, sparks and other sources of ignition away.

C. Batteries contain acid which is corrosive and poison-ous. DO NOT allow battery acid to contact eyes, skin, fabrics or painted surfaces as serious personal injury or property damage could result. Flush any con-tacted areas thoroughly with water immediately. Always wear an acid-resistant apron and face shield when attempting to jump start the compressor.

D. Remove all vent caps (if so equipped) from the bat-tery or batteries in the compressor. DO NOT permit dirt or foreign matter to enter the open cells.

E. Check fluid level. If low, bring fluid to proper level before attempting to jump start (not applicable to maintenance-free batteries).

F. DO NOT attempt to jump start if fluid is frozen or slushy. Bring batteries up to at least 60°F (16°C) before attempting to jump start or it may explode.

G. Cover open cells of all compressor batteries with clean dampened cloths before attempting to jump start.

H. Attempt to jump start only with a vehicle having a negative ground electrical system with the same volt-age, and is also equipped with a battery or batteries of comparable size or larger than supplied in the compressor. DO NOT attempt to jump start using motor generator sets, welders or other sources of DC power as serious damage may result.

I. Bring the starting vehicle alongside the compressor, but DO NOT permit metal to metal contact between the compressor and the starting vehicle.

J. Set the parking brakes of both the compressor (if pro-vided) and the starting vehicle or otherwise block both sides of all wheels.

K. Place the starting vehicle in neutral or park, turn off all non-essential accessory electrical loads and start its engine.

L. Use only jumper cables that are clean, in good condi-tion and are heavy enough to handle the starting cur-rent.

M. Avoid accidental contact between jumper cable ter-minal clips or clamps and any metallic portion of either the compressor or the starting vehicle to mini-mize the possibility of uncontrolled arcing which might serve as a source of ignition.

N. Positive battery terminals are usually identified by a plus (+) sign on the terminal and the letters POS

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 7

Page 14: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

adjacent to the terminal. Negative battery terminals are usually identified by the letters NEG adjacent to the terminal or a negative (-) sign.

O. Connect one end of a jumper cable to the positive (POS) (+) battery terminal in the starting vehicle. When jump starting 24V compressors and if the start-ing vehicle is provided with two (2) 12V batteries con-nected in series, connect the jumper cable to the positive (POS) (+) terminal of the ungrounded bat-tery.

P. Connect the other end of the same jumper cable to the positive (POS) (+) terminal of the starter motor battery in the compressor when jump starting 24V compressors, to the positive (POS) (+) terminal of the ungrounded battery in the compressor.

Q. Connect one end of the other jumper cable to the grounded negative (NEG) (-) terminal of the battery in the starting vehicle. When jump starting 24V com-pressors and if the starting vehicle is provided with two (2) 12V batteries connected in series, connect the jumper cable to the negative (NEG) (-) terminal of the grounded battery.

R. Check your connections. DO NOT attempt to start a 24V compressor with one 12V battery in the starting vehicle. DO NOT apply 24V to one 12V battery in the compressor.

S. Connect the other end of this same jumper cable to a clean portion of the compressor engine block away from fuel lines, the crank case breather opening and the battery.

T. Start the compressor in accordance with normal pro-cedure. Avoid prolonged cranking.

U. Allow the compressor to warm up. When the com-pressor is warm and operating smoothly at normal idle RPM, disconnect the jumper cable from the engine block in the compressor, then disconnect the other end of this same cable from the grounded neg-ative (NEG) (-) terminal of the battery in the starting vehicle. Then disconnect the other jumper cable from the positive (POS) (+) terminal of the battery in the compressor, or if provided with two (2) 12V batteries connected in series, from the ungrounded battery in the compressor, and finally, disconnect the other end of this same jumper cable from the positive (POS) (+) terminal of the battery in the starting vehicle or from the positive (POS) (+) terminal of the ungrounded battery in the starting vehicle, if it is provided with two (2) 12V batteries connected in series.

V. Remove and carefully dispose of the dampened cloths, as they may now be contaminated with acid, then replace all vent caps.

1.13 Towing1

1.13.1 Preparing to tow

A. Prior to hitching the air compressor to the tow vehi-cle, inspect all attachment parts and equipment, checking for (I) signs of excessive wear or corrosion, (II) parts that are cracked, bent, dented or otherwise deformed or degraded, and (III) loose nuts, bolts or other fasteners. Should any such condition be pres-ent, DO NOT TOW until the problem is corrected.

B. Back the tow vehicle to the compressor and position it in preparation for coupling the compressor.

C. If the compressor is provided with a drawbar latched in the vertical upright position, carefully unlatch draw-bar and lower it to engage the coupling device. If not, raise drawbar with the jack to engage coupling device or otherwise couple the compressor to the towing vehicle.

WARNING

Do NOT tow the compressor should its weight exceed the rated limit of the tow vehicle, as the vehicle may not brake safely with excess weight. See rated limit in tow vehicle Operator's Manual, and review its instructions and other require-ments for safe towing.

WARNING

This equipment may be tongue heavy. DO NOT attempt to raise or lower the drawbar by hand if the weight is more than you can safely handle.

Use the screw jack provided or a chain fall if you cannot lift or lower it without avoiding injury to yourself or others. Keep hands and fingers clear of the coupling device and all other pinch points. Keep feet clear of drawbar to avoid injury in case it should slip from your hands.

1 While not towed in the usual sense of the word, many of these instructions are directly applicable to skid-mounted portable air compressors as well.

02250216-781 R018 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 15: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 1: Safety

D. Make sure the coupling device is fully engaged, closed and locked.

E. If chains are provided, pass each chain through its point of attachment on the towing vehicle; then hook each chain to itself by passing the grab hook over (not through) a link. Cross chains under the front of drawbar before passing them through points of attachment on towing vehicle to support the front of drawbar in case it should accidentally become uncoupled.

F. Make sure that the coupling device and adjacent structures on the towing vehicle (and also, if utilized, chain adjustment, brake and/or electrical intercon-nections) DO NOT interfere with or restrict motion of any part of the compressor, including its coupling device, with respect to the towing vehicle when maneuvering over any anticipated terrain.

G. If provided, make sure chain length, brake and elec-trical interconnections provide sufficient slack to pre-vent strain when cornering and maneuvering, yet are supported so they cannot drag or rub on road, terrain or towing vehicle surfaces which might cause wear that could render them inoperative.

H. On two-wheeled models, fully retract front screw jack and any rear stabilizer legs. If a caster wheel is pro-vided on the screw jack it is part of the screw jack, and can not be removed. Follow the same procedure for stowing away the wheeled jack as you would for the standard screw jack. Pull the pin connecting the jack to the drawbar and raise the screw jack to its full upright position. Rotate the screw jack to its stowed position, parallel to the drawbar, and reinsert the pin. Make sure the jack is secured in place prior to tow-ing.

I. Make sure tires are in good condition and are the size (load range) specified and are inflated to the specified pressures. DO NOT change the tire size or type. Also, make sure wheel bolts, lugs or nuts are tightened to the specified torques.

J. If provided, make sure all dual stop, tail directional and clearance lights are operating properly and that their lenses are clean and functional. Also, make sure all reflectors and reflecting surfaces, including the slow moving vehicle emblem on compressors provided with same, are clean and functional.

K. Make sure all service air hoses (not air brake hoses) are disconnected or are fully stowed and secured on hose reels, if provided.

L. Make sure all access doors and tool box covers are closed and latched. If the compressor is large enough to hold a man, make sure all personnel are out before closing and latching access doors.

WARNING

This equipment may be tongue heavy. DO NOT attempt to raise or lower the drawbar by hand if the weight is more than you can safely handle.

CAUTION

Retract the front screw jack only after attaching the compressor to the tow vehicle. Raise the screw jack to its full up position and pull the pin connecting the jack to the drawbar. Rotate the screw jack to its stowed position, parallel to the drawbar, and reinsert the pin. Make sure the jack is secured in place prior to towing.

If a caster wheel is provided on the screw jack it is part of the screw jack and can not be removed. Follow the same procedure for stow-ing away the wheeled jack as you would for the standard screw jack. Pull the pin connecting the jack to the drawbar and raise the screw jack to its full up position. Rotate the screw jack to its stowed position, parallel to the drawbar, and reinsert the pin. Make sure the jack is secured in place prior to towing.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 9

Page 16: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

M. Make sure parking brakes in towing vehicle are set, or that its wheels are chocked or blocked, or that it is otherwise restrained from moving. Then, release the compressor parking brakes, if provided.

N. Make sure the compressor wheels are not chocked or blocked, and that all tie-downs, if any, are free.

O. Test running brake operation, including breakaway switch operation if provided, before attempting to tow the compressor at its rated speed or less when con-ditions prevail.

P. DO NOT carry loose or inappropriate tools, equip-ment or supplies on or in the compressor.

Q. DO NOT load this equipment with accessories or tools such that it is unbalanced from side to side or front to back. Such unbalance will reduce the towabil-ity of this equipment and may increase the possibility of tipping, rolling over, jackknifing, etc. Loss of control of the towing vehicle may result.

1.13.2 Towing A. Observe all Federal, State, and Local laws while tow-

ing this equipment (including those specifying mini-mum speed).

B. DO NOT exceed the towing speeds listed below under ideal conditions. Reduce your speed according to posted speed limits, weather, traffic, road or terrain conditions:

C. Two axle four-wheel or three axle six-wheel steerable models: 15 mph (24 km/h).

D. All other models: 55 mph (88 km/h).

E. Remember that the portable air compressor may approach or exceed the weight of the towing vehicle. Maintain increased stopping distances accordingly. DO NOT make sudden lane changes, U-turns or other maneuvers. Such maneuvers can cause the compressor to tip, roll over, jackknife or slide and cause loss of control of the towing vehicle. Tipping, rolling over, etc. can occur suddenly without warning. U-turns especially should be made slowly and care-fully.

F. Avoid grades in excess of 15° (27%).

G. Avoid potholes, rocks and other obstructions, and soft shoulders or unstable terrain.

H. Maneuver in a manner that will not exceed the free-dom of motion of the compressor’s drawbar and/ or coupling device, in or on the towing vehicle’s cou-pling device and/or adjacent structure whether tow-

ing forward or backing up, regardless of the terrain being traversed.

I. DO NOT permit personnel to ride in or on the com-pressor.

J. Make sure the area behind, in front of, and under the compressor is clear of all personnel and obstructions prior to towing in any direction.

K. DO NOT permit personnel to stand or ride on the drawbar, or to stand or walk between the compressor and the towing vehicle.

1.13.3 Parking or locating compressorA. Park or locate compressor on a level surface, if pos-

sible. If not, park or locate compressor across grade so the compressor does not tend to roll downhill. DO NOT park or locate compressor on grades exceeding 15° (27%).

B. Make sure compressor is parked or located on a firm surface that can support its weight.

C. Park or locate compressor so the wind, if any, tends to carry the exhaust fumes and radiator heat away from the compressor air inlet openings, and also where the compressor will not be exposed to exces-sive dust from the work site.

D. On steerable models, park compressor with front wheels in straight-ahead position.

E. Set parking brakes and disconnect breakaway switch cable and all other interconnecting electrical and/or brake connections, if provided.

F. Block or chock both sides of all wheels.

G. If provided, unhook chains and remove them from the points of chain attachment on the towing vehicle, then hook chains to bail on drawbar or wrap chains around the drawbar and hook them to themselves to keep chains off the ground which might accelerate rusting.

H. Lower front screw jack and/or any front and rear sta-bilizer legs. Make sure the surface they contact has sufficient load bearing capability to support the weight of the compressor.

WARNING

This equipment may be tongue heavy. DO NOT attempt to raise or lower the drawbar by hand if the weight is more than you can safely handle.

02250216-781 R0110 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 17: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 1: Safety

I. If a caster wheel is provided on the screw jack, it is part of the screw jack and cannot be removed. Follow the same procedure for stowing away the wheeled jack as you would for the standard screw jack. Raise the screw jack to its full upright position and pull the pin connecting the jack to the drawbar. Rotate the screw jack to its stowed position, parallel to the draw-bar and reinsert the pin. Make sure the jack is secured in place prior to towing.

J. Disconnect coupling device, keeping hands and fin-gers clear of all pinch points. If the compressor is provided with a drawbar, DO NOT attempt to lift the drawbar or if hinged, to raise it to the upright position by hand, if the weight is more than you can safely

handle. Use a screwjack or chain fall if you cannot lift or raise the drawbar without avoiding injury to your-self or others.

K. Move the towing vehicle well clear of the parked compressor and erect hazard indicators, barricades and/or flares (if at night) if compressor is parked on or adjacent to public roads. Park so as not to inter-fere with traffic.

1.14 California proposition 65

CAUTION

Retract the front screw jack only after attaching the compressor to the tow vehicle. Raise the screw jack to its full up position and pull the pin connecting the jack to the drawbar. Rotate the screw jack to its stowed position, parallel to the drawbar, and reinsert the pin. Make sure the jack is secured in place prior to towing.

On two-wheeled models, fully retract front screw jack and any rear stabilizer legs. If a caster wheel is provided on the screw jack it is part of the screw jack and can not be removed. Follow the same procedure for stowing away the wheeled jack as you would for the standard screw jack. Pull the pin connecting the jack to the drawbar and raise the screw jack to its full up position. Rotate the screw jack to its stowed position, par-allel to the drawbar, and reinsert the pin. Make sure the jack is secured in place prior to towing.

NOTE

While not towed in the usual sense of the word, many of these instructions are directly applicable to skidmounted portable air compressors as well.

WARNING

California Proposition 65 Warning

Diesel engine exhaust and some of its constitu-ents are known to the State of California to cause cancer, birth defects and other reproduc-tive harm.

Battery posts, terminals and related accessories contain lead and other compounds known to the State of California to cause cancer and birth defects and other reproductive harm. Wash hands after handling.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 11

Page 18: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

1.15 Symbols and referencesThe symbols below may or may not be used. Please refer to the decals set forth on the machine for applicable sym-bols.

DIESEL FUEL HEARING PROTECTION

HARD HAT

SAFETY GLASSES

HOOK HERE

DO NOT REMOVE MANUAL

DO NOT BREATHECOMPRESSED AIR

DO NOT STAND ONSERV. VALVE

DO NOT OPERATEW/ DOORS OPEN

DO NOT OPEN

DO NOT STACK

ELECTRICAL SHOCK

AIR FLOW

HOT SURFACE

PRESSURIZED VESSEL

PRESSURIZED COMPONENT

CLOSED MECHANICAL

FUSE

LOW PRESSURE

READ MANUAL

BRAKES

ROTARY COMPRESSOR

TEST RUN

DRAIN

HIGH PRESSURE

NO

ENGINE

COMPRESSOR

ENGINE OIL

ENGINE COOLANT

WATER

OIL

DO NOT

SHUT-OFF VALVEW/ SAFETY

SAFETY SYMBOLS 1

02250216-781 R0112 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 19: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 1: Safety

DANGEROUS OUTLET

CORROSIVE

WARNING

BELOW TEMPERATURE

DO NOT TOW

BAR/PSI

BATTERY

BATTERY DISCONNECT

OFF

ON

RESET

REMOTELY CONTROLLED

DO NOT MAINTENANCE

ENGINE START

ENGINE ECM

READ/WRITE DATA

INTAKE AIR

EXHAUST GAS

FAN GUARD

BELT GUARD

SERVICE POINT

LOW TEMPERATURE

STD AIR

A/C AIR

24 HOURS

BELTS

FILTER

STRAINERFORK LIFT HERE

DIRECTION OF ROTATION

NO FORKLIFT

SAFETY SYMBOLS 2

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 13

Page 20: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

RADIATOR

LUBRICATION

AXEL

HOUR METER

START

CONTROL

ENGINE WARNING

FUEL LEVEL

ENGINE RPM

ENGINE OILPRESSURE

ENGINE COOLANTTEMPERATURE

COMPRESSORTEMPERATURE

DO NOT MIXCOOLANTS

AFTERCOOLER BYPASS VALVE

COMPRESSOROIL HEAT

STACKING LIMITBY NUMBER

DRAIN HEATER

BATTERY HEATER

ENGINE PREHEATLOW TEMP AID

COMPRESSOR AIR PRESSURE

AIR-CIRCULATINGFAN

AIR-COOLEDOIL COOLER

LIQUID-COOLEDOIL COOLER

TRAILER TOWINGMODE

CRUSH/PINCH POINT

FUNCTIONAL ARROW

PRESSURE CONTROL

INTERNAL FUEL

EXTERNAL FUEL

SIDE DOOR T-LATCH

INLET VALVE SPRING

ENGINE INTAKE AIR FILTER

LUBRICANT GREASE

EXAMINE, CHECK

SAFETY SYMBOLS 3

02250216-781 R0114 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 21: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 1: Safety

DO NOT OPERATEWHILE STACKED

DO NOT MIX FLUIDS

AUTO START/STOP

DPF: DIESELPARTICULATE FILTER

DPF REGEN. INHIBIT

FLUID DRAIN

PRESSURIZED SPRING

WATER DRAIN

SEVER (FAN)

DEF FLUID ONLY

RUN

SAFETY SYMBOLS 4

LOW FUEL

HEST: HIGH EMISSIONS SYSTEM TEMPERATURE

EMISSIONSMALFUNCTIONINDICATION

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 15

Page 22: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

1: Safety 185 T4F Kubota User Manual

Notes:

02250216-781 R0116 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 23: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Section 2

185 T4F Kubota User Manual 2: Description

Description

2.1 IntroductionThe Sullair 185 CFM Standard Portable Air Compressor offers superior performance, reliability and require a mini-mal amount of maintenance. Compared to other com-pressors, Sullair’s are unique in terms of reliability and durability. Compressor internal components require no routine maintenance inspections.

2.2 Description of componentsFigure 2-1 on page 18 shows the main components and subassemblies of the Sullair 185 Standard Portable Air Compressor. These packages include a heavy duty rotary screw air compressor, a diesel engine, fuel tank, compressor inlet system, compressor cooling and lubri-cation system, compressor discharge system, capacity control system, instrument panel and electrical system. A low profile canopy offers improved handling and mobility. A clamshell canopy provides easy access to all service-able components.

The control system can easily be adjusted for pressures from 80 to 125 psig (5.6 to 8.6 bar). The compressor unit is driven by an industrial diesel engine designed to pro-vide enough horsepower to provide an adequate reserve under rated conditions.

Refer to the Engine Operator’s Manual for a more detailed description of the engine. The engine cooling system is comprised of a radiator, high capacity fan, and thermostat. The high capacity fan pushes air through the radiator to maintain the engine’s specified operating tem-perature. The same fan also cools the fluid in the com-pressor cooling and lubrication system.

The engine radiator and the compressor fluid cooler are next to each other allowing the fan air to push through both simultaneously. As air passes through the fluid cooler, the heat of compression is removed from the fluid.

2.3 Sullair compressor unit, functional description

Sullair compressors are single-stage, positive displace-ment, flood lubricated-type compressors that provide

continuous (pulse-free) compression to meet various demand loads. Sullair compressors require no routine maintenance or inspection of their internal parts or sys-tems. The compressor works by injecting fluid into the compressor unit where it mixes directly with the air as the rotors turn. The fluid flow has three main functions:

• It acts as a coolant, to control the rise of air temperature which is generated by compres-sion (heat of compression).

• Seals the leakage paths between the rotors and the stator and also between the rotors themselves.

• Lubricates the rotors allowing one rotor to directly drive the other.

After the air/fluid mixture is discharged from the compres-sor unit, the fluid is separated from the air. At this time, the air flows to the service line and the fluid is cooled in preparation for re-injection.

2.4 Compressor cooling and lubrication system, functional description

Refer to Figure 2-2 on page 19 The compressor cooling and lubrication system is designed to provide adequate lubrication as well as maintain the proper operating tem-perature of the compressor. In addition to the fluid cooler and interconnecting piping, the system consists also of three other components: a fluid filter, thermal valve, and a fan which perform the following functions:

• The fluid filter removes and collects any con-taminants in the fluid.

• The thermal valve functions as a temperature regulator directing fluid either to the cooler or to the compressor unit.

• The fan pushes air through the cooler dissipat-ing the heat resulting from compression of the fluid.

The functions of the lubrication system are explained in more detail below. Fluid is used in the system as a cool-ant and as a lubricant: the receiver tank serves as the

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 17

Page 24: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description 185 T4F Kubota User Manual

Figure 2-1: 185 T4 Kubota rotary screw portable air compressor

1. Minimum pressure/check valve 10. Fuel tank

2. Engine air filter 11. Compressor air filter

3. Coolant overflow bottle 12. Thermal valve/compressor fluid filter

4. Radiator/fluid cooler assembly 13. Battery

5. Fuel/water separator 14. Compressor air end

6. Service valves 15. Fluid fill

7. Pressure regulator & blowdown manifold 16. Fluid level sight glass

8. Fuel pump 17. Receiver tank

9. Fuel filter

02250216-781 R0118 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 25: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 2: Description

fluid reservoir. At start-up, fluid flows from the receiver tank to the fluid thermal valve. Fluid circulation is achieved by forcing the fluid from the high pressure region of the receiver tank to a lower pressure area in the compressor unit. A minimum pressure device (See Sec-tion 2.5: Compressor discharge system, functional description on page 19) is provided to assure adequate fluid flow under all conditions. When entering the thermal valve upon start-up, the fluid temperature is cool and thus it is not necessary to route it through the cooler. The fluid flows through the fluid filter and on to the compressor unit bypassing the cooler. As the compressor continues to operate, the temperature of the fluid rises and the ther-mostatic control opens, allowing a portion of the fluid into the cooler.

When the temperature reaches 160°F (71°C), the ther-mostat is fully open allowing all fluid entering the thermal valve to flow to the cooler.

The cooler is a radiator type that works in concert with the engine fan. The fan pushes air through the cooler

removing the heat from the fluid. From the cooler, the fluid is then routed back through the fluid filter. All fluid flowing to the compressor unit passes through this filter. The fluid leaving the filter flows to the compressor unit where it lubricates, seals and cools the compression chamber; and lubricates the bearings and gears.

2.5 Compressor discharge system, functional description

Refer to Figure 2-2 on page 19. The Sullair compressor unit discharges a compressed air/fluid mixture into the receiver tank. The receiver tank has three functions:

• It acts as a primary fluid separator.

• Serves as the compressor fluid reservoir.

• Houses the air/fluid separator.

The compressed air/fluid mixture enters the receiver tank and is directed against its side. Because of a change of direction and reduction of velocity, large droplets of fluid

Figure 2-2: Compressor cooling and lubrication system

1. Fluid cooler 4. Fluid filter

2. Compressor 5. Receiver tank

3. Thermal valve

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 19

Page 26: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description 185 T4F Kubota User Manual

separate and fall to the bottom of the receiver tank. The small amount of fluid remaining in the compressed air collects on the surface of the separator element as the compressed air flows through the separator. As more fluid collects on the element surface, it then flows to the bottom of the separator. A return line (or scavenge tube) leads from the bottom of the separator element to the inlet region of the compressor unit. Fluid collecting on the bottom of the separator element is returned to the com-pressor by the pressure difference between the area sur-rounding the separator element and the compressor inlet. An orifice (protected by a strainer) is included in this return line to assure proper and unobstructed flow. The receiver tank is code rated at 200 psig (13.8 bar) working pressure. A minimum pressure device located down-stream from the separator, ensures a minimum receiver pressure of 80 psig (5.5 bar) during all conditions. Keep-ing this pressure level stable is necessary for proper air/fluid separation and proper fluid circulation. A pressure relief valve (located on the wet side of the separator) is

set to open if the receiver tank pressure exceeds 200 psig (13.8 bar).

2.6 Capacity control system, functional description

Refer to Figure 2-3 on page 20. The purpose of the con-trol system is to regulate the amount of air intake and match it to the demand (required output) on the compres-sor. The control system consists of a pressure regulating valve(s), air inlet valve, system blowdown valve, engine speed control, and tubing connecting the various compo-

WARNING

Do not remove caps, plugs and/or other compo-nents when the compressor is running or pres-surized. Stop the compressor and relieve all internal pressure before removing these items.

Figure 2-3: Compressor discharge system

1. Receiver tank 4. Compressor unit

2. Minimum pressure/check valve 5. Service air outlets

3. Internal air/oil separator element

02250216-781 R0120 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 27: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 2: Description

nents of the compressor. The functional descriptions of the control system are described by relating them to four distinct phases of operation. They apply to any control system with the exception of those with specified pres-sures which are dependent on pressure requirements. The given values apply to a compressor with an operat-ing pressure range of 100 to 125 psig (6.9 to 8.6 bar).

2.6.1 Start—0 to 58 psig (0 to 4.0 bar)When the compressor is started, the receiver tank pres-sure quickly rises from 0 to 58 psig (0 to 4.0 bar). During this period the pressure regulator valve is inactive. At this pressure range the idle warm-up control keeps the inlet valve closed for engine idle operation. Within 30 seconds of starting the compressor (the instrument controller READY status light is on) turn the handle of the warm-up selector valve (located on the instrument panel) from the START to the RUN position. The inlet valve is fully open due to inlet pressure, and the compressor operates at full capacity. When the compressor operates at full capacity, the engine runs at full speed.

2.6.2 Normal operation—80 to 100 psig (5.6 to 6.9 bar)

When the warm-up control selector valve handle is moved to the RUN position, the receiver tank pressure rises above 80 psig (5.6 bar). At this time, the inlet valve remains fully open for maximum air output. The engine will continue to run at full speed during this phase of operation.

2.6.3 Modulation—100 to 125 psig (6.9 to 8.6 bar)

If the demand on the compressor is less than its rated capacity, the service line pressure will rise above 125 psig (8.6 bar). The pressure regulating valve gradu-ally opens, applying pressure to the inlet valve piston and engine speed control. This causes the inlet valve to par-tially close and reduces the engine speed. As the pres-sure increases, the inlet valve piston will further close the inlet valve and the engine speed will decrease until it reaches its preset idle speed. When the demand on the compressor increases, the receiver tank pressure falls below 125 psig (8.6 bar). The pressure regulating valve closes, the air inlet valve opens fully, and the engine speed increases to its preset full load rating.

Between the pressure regulating valve and the inlet valve, there is a small orifice that vents a small amount of air into the atmosphere when the pressure regulating valve is open. This allows changes in air output to con-form to air demand. This orifice also discharges any accumulated moisture from the regulator.

2.6.4 ShutdownThe blowdown valve is normally closed. At shutdown the back pressure in the compressor inlet signals the blow-down valve to vent the receiver tank pressure into the atmosphere.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 21

Page 28: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description

185 T4F Kubota U

ser Manual

22 2.7 Piping and instrumentation—compressor system

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

02250210-170 R02 (sh1)

Page 29: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota U

ser Manual

2: Description

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

23

ATURE SWITCH

URE

2.7 Piping and instrumentation—compressor systemComponentsKey Description

01 FILTER, AIR

02 GAUGE, FILTER RESTRICTION (OPTONAL)

03 INLET VALVE

04 COMPRESSOR

05 SWITCH, TEMPERATURE

06 VALVE, RELIEF

07 RECEIVER, AIR/OIL

08 GLASS, SIGHT OIL LEVEL

09 VALVE, MINIMUM PRESSURE/CHECK

10 VALVE, BALL

11 ORIFICE

12 VALVE, BLOWDOWN N.C.

13 STRAINER

14 VALVE, THERMAL BYPASS

15 COOLER, OIL

16 FILTER, OIL

17 GAUGE, PRESSURE

18 VALVE, PRESSURE REGULATOR

19 VALVE, 3-WAY SELECTOR

20 VALVE, CHECK

21 SEPARATOR, AIR/OIL

22 PRESSURE TRANSDUCER

23 OPTIONAL TEMP SENSOR

Component Description

T1 RECIEVER TANK TEMPER

P1 DRY SIDE SERVICE PRESS

Page 30: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description

185 T4F Kubota U

ser Manual

24 2.8 Piping and instrumentation—engine system

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

02250210-170 R02 (sh2)

Page 31: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota U

ser Manual

2: Description

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

25

SENSOR

2.8 Piping and instrumentation—engine systemComponentsKey Description

01 TURBOCHARGER, COMPRESSOR

02 COOLANTFILL

03 OVERFLOW BOTTLE

04 FUEL LEVEL SENDER W/SWITCH (OPTIONAL)

05 RAIN CAP, EXHAUST SYSTEM

06 FUEL FILTER W/ WATER SEPARATOR

07 FUEL INJECTION PUMP

08 ELECTRIC FUEL PRIMING PUMP

09 FILTER, FUEL

11 FUEL TANK CAP W/VENT

12 THERMOSTAT, THERMOCORD(OPTIONAL)

13 FILTER, DEISEL PARTICULATE

14 OIL PUMP (INTEGRAL TO ENGINE)

15 BY-PASS VALVE (INTERNAL TO ENGINE)

16 COOLER, OIL (INTERNAL TO ENGINE)

17 FILTER, OIL

18 WATER PUMP (INTEGRAL TO ENGINE)

19 RADIATOR, ENGINE

20 ENGINE THERMOSTAT (INTEGRAL TO ENGINE)

21 ENGINE OIL PAN

22 GAUGE, FILTER RESTRICTION

23 TANK, FUEL

24 FILTER,AIR

25 SENSOR, COOLANT TEMPERATURE

26 SENSOR, ENGINE OIL PRESSURE

27 JACKET WATER HEATER (OPTIONAL)

28 OIL LEVEL (DIPSTICK)

Component Description

L1 FUEL LEVEL

L2 OIL LEVEL (DIPSTICK)

P2 OIL PRESSURE

T2 COOLANT TEMPERATURE

Page 32: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description 185 T4F Kubota User Manual

2.9 Air inlet system, functional description

The air inlet system consists of two air filters, a compres-sor air inlet valve and interconnecting piping to the engine and the compressor.

The air filters are two-stage dry element type filters that are capable of cleaning extremely dirty air. However, when operating in dirty environments, the filters should be checked more frequently.

See Section 5.9.3: Air filter maintenance on page 48 for air filter maintenance procedures.

2.10 Instrument panel group, functional description

Refer to Figure 2-4 on page 27 for the locations of the fol-lowing indicators and controls:

1. The master gauge continuously monitors the receiver tank pressure and displays engine and compressor status.

2. The LCD display displays the status of the engine and the compressor.

3. The user interface buttons navigate the LCD display screen.

4. The active regeneration lamp helps to indi-cate regeneration status. See Section 2.11: Engine exhaust after-treatment on page 28.

5. The regeneration needed / request lamphelps to indicate regeneration status. See Section 2.11: Engine exhaust after-treatmenton page 28.

6. The engine shutdown lamp indicates that the engine should be shut down immediately to prevent engine damage. Always correct the problem that caused the shutdown before restarting the compressor.

7. The compressor shutdown lamp indicates the engine and compressor safety shutdown status.

8. If equipped with the fuel level sender option, the low fuel lamp indicates that the fuel level is near the shutdown level.

• If equipped with the fuel level sender option, you can also view the fuel tank level on the LCD display.

9. The inhibit lamp indicates that regeneration is inhibited. See Section 2.11: Engine exhaust after-treatment on page 28.

10. The compressor warning lamp indicates a compressor fault has occurred.

11. The engine warning lamp indicates that an abnormal condition exists in the engine sys-tem. You do not need to shutdown the com-pressor and correct the problem immediately, but you should correct the prob-lem as soon as possible.

12. The START/ON/OFF switch energizes the system and starts the compressor. The engine switch is pressed to the ON position to energize the electrical system, and pressed momentarily to the START position to engage the starter and start the compres-sor.

13. The FORCE/REGEN/INHIBIT regeneration switch controls after-treatment of the engine exhaust. See Section 2.11: Engine exhaust after-treatment on page 28.

• If the inhibit lamp is not lit, pressing INHIBIT will inhibit regeneration.

• If the inhibit lamp is lit, pressing INHIBITwill allow the compressor to regenerate normally.

14. The diagnostic service port is used to con-nect a service diagnostic tool.

15. The idle warm-up control reduces compres-sor load at start-up. Turned the control from START to RUN after the compressor warms up for full compressor operation.

WARNING

Do not use aerosol types of starting aids such as ether.

Such use could result in an explosion and per-sonal injury.

If the engine fails to start during the automatic startup sequence, wait two minutes to allow the starting motor to cool before attempting to start the engine again.

02250216-781 R0126 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 33: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 2: Description

Figure 2-4: Instrument panel

1. Master gauge 9. Inhibit lamp

2. LCD display 10. Compressor warning lamp

3. User interface buttons 11. Engine warning lamp

4. Active regeneration lamp 12. START/ON/OFF switch

5. Regeneration needed / request lamp 13. FORCE/REGEN/INHIBIT regeneration switch

6. Engine shutdown lamp 14. Engine controller diagnostic service port

7. Compressor shutdown lamp 15. Compressor warm-up control (START/RUN)

8. Low fuel lamp

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 27

Page 34: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description 185 T4F Kubota User Manual

2.11 Engine exhaust after-treatmentTier 4 engine emission regulations require the installation of exhaust filters (EF) on most engines. The exhaust fil-ters discussed here consist primarily of a diesel oxidation catalyst (DOC) and a diesel particulate filter (DPF). The exhaust flows from the engine through the DOC and then the DPF. The DOC reduces hydrocarbon (HC) emissions, enables passive regeneration of the DPF, and oxidizes dosed hydrocarbon for active cleaning of the DPF. The DPF traps diesel particulate (primarily carbon soot) from the exhaust. Any engine fitted with an EF must be run on ultra-low sulfur fuel and low ash CJ-4 or equivalent lubri-cating oil.

During normal operation, the diesel particulate filter (DPF) accumulates soot. When that soot level reaches a certain level, the engine control unit (ECU) determines that the DPF needs to be cleaned or “regenerated”. At that time, the ECU prepares the diesel oxidation catalyst (DOC) through exhaust temperature management. When the DOC reaches the required temperature, hydrocarbon (HC) fuel dosing is activated.

After a period of high temperature cleaning, the DPF is ready to trap more particulate and the engine returns to

normal operation. The frequency of cleaning is highly dependant on the engine operating conditions.

Your Sullair compressor’s engine exhaust regenerates in one of several different ways, depending on the com-pressor’s operating conditions.

• Passive regeneration. Continuous regenera-tion due to high exhaust temperature.

• Active regeneration. Automatic controlled regeneration with the aid of post injection despite low exhaust temperature. Machine operation is not interrupted.

• Parked regeneration. Machine is manually placed in Start mode and the FORCE/REGEN/INHIBIT switch is in the FORCE position. Nor-mal operations are not possible in parked regeneration. Machine should be left to finish a parked regeneration unless it is absolutely nec-essary to take it out of regeneration or to shut down the machine. If machine is not allowed to regenerate while in parked regeneration, the DPF may become damaged and need to be serviced or replaced.

02250216-781 R0128 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 35: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 2: Description

Table 2-1: Engine exhaust regeneration lamp sequence

Particulate level Active/Parked regenerationInhibit lamp

Active regeneration

lamp

Regeneration needed /

request lamp Engine lamps

Level 0: Passive regeneration only

Regeneration not needed ON OFF OFF OFF

Regeneration not needed OFF OFF OFF OFF

Level 1: Active regenerationActive regeneration needed ON OFF SOLID LIGHT OFF

Active regeneration occurring OFF SOLID LIGHT SOLID LIGHT OFF

Level 2: Active / parked regeneration

Active regeneration needed ON OFF BLINKING LIGHT OFF

Parked regeneration needed ON OFF BLINKING LIGHT OFF

Active regeneration occurring OFF SOLID LIGHT SOLID LIGHT OFF

Parked regeneration occurring OFF SOLID LIGHT SOLID LIGHT OFF

Level 3: De-rating power & speed

Parked regeneration needed ON OFF BLINKING LIGHT

WARNING

Parked regeneration occurring OFF SOLID LIGHT SOLID LIGHT

WARNING

Level 4: De-rating power & speed

Parked regeneration needed (Kubota service) ON OFF BLINKING LIGHT

WARNING

Parked regeneration occurring (Kubota service) OFF SOLID LIGHT SOLID LIGHT

WARNING

Level 5: Engine stop

DPF service required ON OFF BLINKING LIGHT

SHUTDOWN

DPF service required OFF OFF BLINKING LIGHT

SHUTDOWN

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 29

Page 36: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description

185 T4F Kubota U

ser Manual

30 2.12 Wiring diagram

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

02250214-326(r10)

Page 37: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota U

ser Manual

2: Description

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

31

UG RELAY

ELAY

AY

WN RELAY

2.12 Wiring diagram

ISO 280 relay socket (bottom view)

Cooper/Bussmann 15303-4-0-4S RTMR power distribution module

Drawing notes

A1 TO BATTERY POSITIVE

A2 TO BATTERY SIDE OF DISCONNECT SWITCH

30COM

86COIL+

85COIL-

87ANC

87NO

AA A B C D

KEYSWITCH 5022 5032 1 3261 2503

GLOW PLALTERNATOR 5003 5013 2 1353 D 3251

IGNITION SWITCH 226A4 2264 3

GLOW PLUGS 3261 3441 4 3311 3614

START RSTART SWITCH 2164 216A4 5 3134 D 3301

EGR 63 3243 6 3271 3284

EGR RELCONTROL POWER 3401 3391 7 2414 D 3243

KEYSWITCH/SHUTDOWN 3413 3363 8

SHUTDOSTARTER RELAY POWER 3423 3311 9 3363 3383

ECU POWER 3431 3271 10 3184 2183 3564

D=DUMMY OR DEAD END CONTACT TO PROVIDE COMPLETE 5 CONTACT RELAY CONNECTION

Page 38: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

2: Description 185 T4F Kubota User Manual

2.13 Electrical system, functional description

The electrical system consists of the basic electrical ele-ments required to operate the compressor and also has a system feature that automatically shuts down the com-pressor when a malfunction occurs. The system’s com-ponents include: an engine starter, battery, alternator/ voltage regulator, and a fuel solenoid. It also has a com-

pressor discharge temperature switch that will shut the compressor down if the compressor temperature exceeds 250°F (121°C). The single axle controller will shut the compressor down if the engine speed falls below 1300 rpm and an optional low fuel level switch shuts down the engine when fuel level is low to prevent running the engine dry (out of fuel). The engine is also equipped with an ECU (engine control unit).

02250216-781 R0132 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 39: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Section 3

185 T4F Kubota User Manual 3: Specifications

Specifications

3.1 Specifications—49HP 185 Kubota

Table 3-1: Package specifications

Model series 49HP 185

Package DPQ DLQ

Working weightlbs 2175 1950

kg 987 885

Dry weightlbs 1960 1740

kg 889 789

Length (with standard drawbar)

in 130.8 79.3

mm 3322 2014

Widthin 59.2 40.7

mm 1504 1034

Heightin 58 47.8

mm 1473 1214

Track widthin 50.9 n/a

mm 1293 n/a

Maximum towing speedmph 55 n/a

km/h 89 n/a

Axle ratinglbs 3700 n/a

kg 1678 n/a

Tire size ST175/80D13 n/a

Tire pressurepsig 50 n/a

bar 3.4 n/a

Lug nut torquelb-ft 60 n/a

N•m 81 n/a

Table 3-2: Compressor specifications

Model series 49HP 185

Type Rotary screw

Actual deliverycfm 185

m3/min 5.2

Rated pressurepsig 100

bar 6.9

Pressure range, min.psig 80

bar 5.5

Pressure range, max.psig 125

bar 8.6

Service valvesnumber 2

size 3/4"

Compressor fluid capacitygal 2.1

L 7.9

Receiver tank volumeft3 n/a

m3 n/a

Maximum operating altitudeft 9000

m 2743

Fuel consumption, 100% loadgph 2.7

L/h 10.2

Compressor discharge shutdown temperature

°F 250

°C 121

Operating tilt (maximum) 15°

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 33

Page 40: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

3: Specifications 185 T4F Kubota User Manual

3.2 Lubrication guide—compressor

3.3 Lubrication guide—engineRefer to the Kubota Diesel Engine Operation and Mainte-nance Manual for engine oil specifications.

Table 3-3: Engine specifications

Model Series 49HP 185

Type Diesel

Make Kubota

Model KUB1803 (T4F)

Emissions level U.S. EPA Tier 4 final

Operating speed rpm 2720

Minimum idle speed rpm 1800

Electrical system voltage 12

Battery rating CCA 1000

Available powerbhp 49

kW 36.5

Displacement in3 134

cm3 2196

Cooling system capacitygal 2.75

L 10.4

Engine oil capacityqts 7.3

L 6.9

Fuel tank capacitygal 27

L 102.2

Cylinders 3

Fluid type

Change period, hours

Ambient temperature range

°F °C

Sullair AWF® 1 1500 -20 to 120 -29 to 491Sullair AWF part numbers: 250030-757 (5 gallons/18.9 liters) and 250030-758 (55 gallon/208 liter drum)

02250216-781 R0134 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 41: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 3: Specifications

3.4 Application guideSullair portable air compressors are filled with Sullair AWF®. Sullair AWF is a heavy-duty, multi-viscosity, all-weather fluid suitable to a wide variety of conditions, including conditions that can cause severe fluid oxida-tion.

Periodically drain the condensate from the air/fluid sepa-rator. In high ambient temperature and high humidity con-ditions, condensed moisture can emulsify with the fluid (indicated by the fluid turning a “milky” color). Change the fluid if this condition develops.

Do not mix different types or brands of fluid. Mixing dif-ferent types or brands of fluids can lead to operational problems such as foaming, plugged filters, blocked ori-fices or lines, or even severe problems like a plugged cooler or a locked air end.

Contact your Sullair representative for fluid recommenda-tions if operating conditions require the use of an extended life fluid (for example, the ambient temperature is outside the recommended temperature range for Sul-lair AWF).

Sullair encourages users to participate in a fluid analysis program. The analysis might indicate a need for change intervals different from those recommended in this man-ual (for example, to maximize the life of the machine in dirty environments). Contact your Sullair representative for details.

NOTE

Proper compressor fluid level visible halfway in fluid sight glass when checked on a level surface with the compressor not running.

Figure 3-1: Receiver tank

1. Receiver/tank

2. Sight glass

3. Fluid fill port

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 35

Page 42: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

3: Specifications185 T4F K

ubota User M

anual

36 3.5 Identification—DPQ

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

02250214-081 R02

Page 43: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota U

ser Manual

3: Specifications

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

37

3.5 Identification—DPQ

Drawing notes

1 DIMENSIONS ARE IN INCHES. [ ] DIMENSIONS ARE IN MILLIMETERS.

2 REFERENCE: A STANDARD CONTAINER SIZE IS 92" WIDE X 94" TALL X 232" LONG.

3 ALL DIMENSIONS ARE +/- .50" [12.7mm]

A1 ENGINE COOLANT DRAIN FLEXIBLE HOSE

A2 ENGINE OIL DRAIN FLEXIBLE HOSE

A3 COMPRESSOR OIL DRAIN

A4 LIFTING BAIL EYE (APPROX. CENTER OF GRAVITY)

A5 TIEDOWN NOT SHOWN(4-PLACES)

A6 INSTRUMENT PANEL DOOR

A7 ENGINE EXHAUST AIR OUT (3" DIA)

A8 ENGINE FUEL FILL

A9 ENGINE COOLANT FILL

A10 ENGINE COOLANT OVERFLOW ACCESS

A11 COMPRESSOR OIL FILL AND SIGHT GLASS

A12 AIR INTAKE

A13 BATTERY ACCESS

A14 AIR FILTER ELEMENT ACCESS

A15 AIR OUTLET

A16 OVERALL HEIGHT (STANDARD MACHINE)

A17 OVERALL WIDTH

A18 OVERALL LENGTH

A19 FUEL TANK DRAIN

Option

Add to dimension “A”

in mm

Standard eye 0 0

Ball hitch .75 19

Extended drawbar with standard eye 21.25 540

Page 44: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

3: Specifications185 T4F K

ubota User M

anual

38 3.6 Identification—DLQ

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

02250224-015 R00

Page 45: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota U

ser Manual

3: Specifications

02250216-781 R01

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

39

3.6 Identification—DLQ

Drawing notes

1 DIMENSIONS ARE IN INCHES. [ ] DIMENSIONS ARE IN MILLIMETERS.

2 REFERENCE: A STANDARD CONTAINER SIZE IS 92" WIDE X 94" TALL X 232" LONG.

3 ALL DIMENSIONS ARE +/- .50" [12.7mm]

A1 ENGINE COOLANT DRAIN FLEXIBLE HOSE

A2 ENGINE OIL DRAIN FLEXIBLE HOSE

A3 COMPRESSOR OIL DRAIN

A4 LIFTING BAIL EYE (APPROX. CENTER OF GRAVITY)

A5 INSTRUMENT PANEL DOOR

A6 ENGINE EXHAUST AIR OUT (3" DIA)

A7 ENGINE FUEL FILL

A8 ENGINE COOLANT FILL

A9 ENGINE COOLANT OVERFLOW ACCESS

A10 COMPRESSOR OIL FILL AND SIGHT GLASS

A11 AIR INTAKE

A12 BATTERY ACCESS

A13 AIR FILTER ELEMENT ACCESS

A14 AIR OUTLET

A15 OVERALL HEIGHT (STANDARD MACHINE)

A16 OVERALL WIDTH

A17 OVERALL LENGTH

A18 FUEL TANK DRAIN

A19 MOUNTING HOLES

Page 46: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

3: Specifications 185 T4F Kubota User Manual

Notes:

02250216-781 R0140 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 47: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Section 4

185 T4F Kubota User Manual 4: Operation

Operation

4.1 GeneralWhile Sullair has built into this compressor a complete set of controls and indicators that allow the operator to control and monitor the compressor’s operation and per-formance, operators should learn to recognize indica-tions which identify a service requirement or conditions that could lead to (or show) a (current) malfunction. Before starting the compressor, read this section thor-oughly to gain familiarity with the controls and indica-tors—their function and location.

4.2 Purpose of controls

Engine switchPress this switch to the ON (ignition) position to energize the electrical system of the compressor. Press the switch to the START position to momentarily engage the starter and start the compressor. Press the switch to the OFFposition to shut the compressor down. This switch is located on the instrument panel.

Regeneration switchWhen the regeneration switch is in the REGEN position, regeneration occurs normally. When the switch is in the INIHIBIT position, regeneration is prevented. When the switch is in the FORCE position, regeneration occurs immediately if the conditions for regeneration are met.

Air pressure gaugeContinuously monitors the pressure inside the receiver tank.

Fluid level sight glassIndicates the fluid level in the receiver tank. Proper level is marked halfway up the sight glass. Check the level when the compressor is shutdown and on level ground.

Compressor discharge temperature switchOpens the electrical circuit to shut down the compressor when the discharge temperature reaches the compressor discharge shutdown temperature (see Section 3.1: Spec-ifications—49HP 185 Kubota on page 33).

Thermal valveFunctions as a temperature regulator by directing the compressor fluid either to the cooler or to the compressor unit.

Minimum pressure deviceMaintains the minimum of 80 psig (5.6 bar) in the com-pressor receiver tank.

Pressure relief valveVents receiver tank pressure to the atmosphere if pres-sure inside the receiver tank exceeds 200 psig (13.8 bar).

Air inlet valveControls the amount of air allowed to enter the air com-pressor inlet. Regulation is determined by a signal from the pressure regulator(s).

Blowdown valveVents receiver tank pressure to the atmosphere at shut-down.

Idle warm-up controlKeeps the compressor inlet valve closed for reduced compressor load at start-up. When the compressor is warmed-up, the handle is turned from the START to the RUN position for full operation.

4.3 Starting the compressor

1. Ensure that the compressor is on a level sur-face.

WARNING

Do not use aerosol types of starting aids such as ether.1 Such use could result in an explosion and personal injury.1Unless the starting aid is factory-installed or an aftermarket kit designed specifically for use with the Sullair provided ether start electrical connector.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 41

Page 48: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

4: Operation 185 T4F Kubota User Manual

• If the compressor is on an uneven surface, the fluid sight gauge readings will not be accurate, and it will not be possible to determine if fluid levels are too low.

2. Ensure that a minimum clearance of 3 feet is provided all the way around the machine to allow exhaust gas to ventilate before operat-ing the machine.

• Failure to ventilate hot exhaust gas can result in improper functioning of machine and the heat build-up can result in melting of rubber and/or plastic components.

3. Check all oil and fluid levels in the engine and compressor. Add oil and/or fluid if nec-essary.

4. Fill the fuel tank and drain any water from the fuel/ water separator.

5. Check the dust collectors and clean if neces-sary.

6. Crack open one service line.

7. Turn the WARM-UP CONTROL control to the START position.

• When the Single Axle Controller is initially powered up, the system will initiate a “Self Test” sequence to verify its operational integrity and safety status. During this pro-cess, the following actions will be per-formed.

1. Gauge pointers will move to the zero position, then to half and full scale, then back to zero, and finally to the actual value reading.

2. The LCD display will turn on all its segments for one second, off for one second, and then display the Sullair logo followed by the software prod-uct number with revision level.

3. All warning lights will turn on for 2.5 seconds and then turn off, then set to the actual indicator state.

8. Toggle the START/ON/OFF switch to the ONposition.

9. Wait for the status message on the display to switch to Ready.

10. Momentarily toggle the START/ON/OFF to the START position and release the switch to engage the starter.

11. After 30 seconds, turn the WARM-UP CON-TROL from START to RUN to put the com-pressor in full operation.

12. Close all doors to maintain proper noise level.

4.4 Shutting down the compressor1. Close the service valves and run the com-

pressor for approximately five minutes to allow the compressor to cool down.

2. (“H” and “HH” models only) Turn the PRES-SURE SELECTOR control to the LOW posi-tion.

3. Toggle the engine switch to the OFF position after five minutes.

WARNING

If an emergency shutdown is required, immedi-ately press the emergency stop button.

Do not use the emergency stop button in place of the normal shutdown procedure described above.

02250216-781 R0142 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 49: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 4: Operation

4.5 TroubleshootingThe following guide contains symptoms and usual causes for the problems that may occur throughout the compressor system. Each warning or fault message that may appear is listed along with conditions for the prob-lem, a probable cause, and a suggested solution to the problem. Do not assume that these are the only troubles that may occur. The following table denotes all warning/shutdown conditions that the Single Axle Controller will sense. Shutdown conditions will display the associated

message on the LCD, light the compressor shutdown panel lamp, shut the system down, and wait for operator to toggle the MENU TOGGLE switch to “EXIT” to acknowledge the fault condition before a restart may be attempted. Warning conditions display the associated message on the LCD and light the compressor warning lamp. Under a warning condition the system will continue to operate normally.

Error MessageWarning/Shutdown/Prevent Startup Description Recommended action

No Message Prevent StartupNo power or initialization of controller.

Turn OFF/ON/START switch to ON position.

Make sure E-stop is not engaged (pull out).

Turn battery disconnect switch to ON position.

Check battery voltage.

Check connections between Sin-gle Axle Controller and harness and at the starter and harness.

Make sure Single Axle Controller internal circuit breakers (4) are closed.

Low Fuel LevelShutdown/Prevent Startup

Fuel level low shutdown threshold reached.

Add fuel and restart.

Comp High TempShutdown/Prevent Startup

CDT sensor is above shut-down setpoint.

Verify thermistor resistance between 803 Ω @ -50°C and 1573 Ω @ 150°C.

Coolers dirty. Clean coolers.

Fan slipping. Check/adjust fan belt tension.

Compressor oil thermostat malfunction.

Replace thermostat.

RTT HighShutdown/Prevent Startup

RTT (Receiver Tank Tem-perature) switch normally closed, has opened.

Replace the RTT switch.

Primary ShutdownShutdown/Prevent Startup

After filter restriction too high (filters dirty).

Replace filters.

After filters dp module malfunction.

Check source voltage and ground and correct if necessary.

Visually inspect for damage and replace if necessary.

WL Comm ErrorShutdown/Prevent Startup

Loss of LIN communica-tion with warning bank module.

Check Single Axle Controller and ensure that all gauge and warn-ing bank connectors are well seated/engaged.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 43

Page 50: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

4: Operation 185 T4F Kubota User Manual

High Comp Pres-sure

Shutdown/Prevent Startup

P1 (Dry) pressure is above setpoint.

Pressure above 10 psi (recent shutdown). Wait for pressure to fall below 10 psi.

Transducers out of cali-bration.

Transducers need to be cali-brated using the gauge calibra-tion subroutine (See “Pressure Calibration” on page 26).

Engine Overcrank ShutdownThe maximum number of engine crank cycles has been exceeded

Check battery voltage & recharge if necessary.

Check starter relay for short to ground.

Check source voltage to starter relay.

Engine Comm Error

Shutdown/Prevent Startup

The Single Axle Control-ler is not properly receiv-ing J1939 messages from the engine ECM.

Check connections at engine ECM and Single Axle Controller.

Check the termination resistor in the harness ECM connector and replace if necessary.

E-Stop PressedShutdown/Prevent Startup

The Single Axle Control-ler will not power up/initial-ize. (No message at controller.)

Disengage E-stop.

The E-stop was used to shut machine down.

Once conditions are deemed safe, toggle the OFF/ON/START switch OFF.

Eng Speed Too Low

Shutdown

Engine speed dropped below preset value for a preset amount of time. This is to protect the vul-canized rubber drive cou-pling between the engine and compressor.

Check fuel level.

Check the inlet valve for prema-ture opening during the warm-up phase.

P1,P2 Signal Error ShutdownError loss of all transducer inputs during run phase.

Check voltage source and ground for good connection.

Low Fuel Level WarningFuel light is on. Compres-sor warning light is on. Fuel level is below 20%.

Add fuel soon.

Error MessageWarning/Shutdown/Prevent Startup Description Recommended action

02250216-781 R0144 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 51: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 4: Operation

Fuel Sender Error WarningThe fuel level sensor sig-nal is out of range.

Check connections at sensor on tank. Verify source voltage and ground.

Wires possibly reversed.

Fuel sensor is defective. Replace.

Single Axle Controller is config-ured incorrectly (configured for level switch only). Reprogram the Single Axle Controller using the Single Axle Controller com-munication software, communi-cation adapter, and PC.

P1 Signal Error Warning

Transducer has no source voltage.

Verify 5 V dc to transducer.

Transducer has lost ground.

Verify path to ground.

Output voltage to control-ler is lost.

Verify 0.5 – 4.5 V dc to controller.

Transducer malfunction. Replace transducer.

P2 Signal ErrorWarning/Shutdown/Prevent Startup

Transducer has no source voltage.

Verify 5 V dc to transducer.

Transducer has lost ground.

Verify path to ground.

Output voltage to control-ler is lost.

Verify 0.5 – 4.5 V dc to controller.

Transducer malfunction. Replace transducer.

Error MessageWarning/Shutdown/Prevent Startup Description Recommended action

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 45

Page 52: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

4: Operation 185 T4F Kubota User Manual

Notes:

02250216-781 R0146 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 53: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Section 5

185 T4F Kubota User Manual 5: Maintenance

Maintenance

5.1 GeneralConsistent and correctly performed maintenance will ensure the compressor’s performance and extend its operational life. See Section 5.9: Part replacement and adjustment procedures on page 48 for a detailed descrip-tion of specific compressor components. Before perform-ing maintenance actions, read the CIMA Safety Manual, if applicable. For engine maintenance requirements and procedures, refer to the Engine Operator’s Manual.

5.2 Engine coolant requirement for radiators

The coolant provided with Sullair portable air compres-sors is ethylene glycol based, 50/50 mixture, and should never be mixed with a different coolant type, color or brand. If radiator coolant is to be added, for any reason, be sure that the coolant added is the same as what is in the cooling system, as well as what is recommended. Refer to the Maintenance section of the Engine Opera-tor’s Manual for proper engine coolant specifications and instructions. Ensure that the proper coolant is used when adding engine coolant to the machine. If you are not sure of the coolant that is installed originally or want to change to a different type, the cooling system must be cleaned with a commercial cleaning agent and completely flushed and filled with distilled water several times to remove all traces of old coolant. Then, fill the system with the rec-ommended coolant using only one brand/type. Cross contamination which is caused by adding different types of engine coolants may result in the coolant additives to deplete (dropout); thus leaving radiator surfaces unpro-tected. Corrosion to radiator surfaces may occur, thus reducing radiator life expectancy. It is extremely impor-

tant to evacuate/purge all air within the cooling system before replacing the radiator cap.

5.3 Daily maintenanceSee Section 4.3: Starting the compressor on page 37 for general operation.

5.4 Maintenance after initial 50 hours of operation

After the initial 50 hours of operation, the following main-tenance actions are required to eliminate contaminants from the system:

• Clean the scavenge return line orifice and change the strainer.

• Change the compressor fluid filter.

• Check the Engine Operator’s Manual for ser-vice requirements.

• Check the fuel filter for water.

• Confirm that the receiver tank cover bolts are tightened to 60 ft-lbs (81 N•m).

WARNING

Do not remove caps, plugs and/or other compo-nents when the compressor is running or pres-surized. Shutdown the compressor before removing any components.

CAUTION

The radiator and engine cooling system must be drained and flushed periodically. Refer to the OEM Engine Manual for more information. Replace the coolant with a solution of 50% ethyl-ene glycol and 50% water or as required for your geographic location. Do not use a leak sealing type of antifreeze. Should a 100% water solution be used, a non-chromate rust inhibitor must be added. Do not mix coolant types.

NOTE

Dispose of fluids in accordance with applicable federal, state and local regulations.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 47

Page 54: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

5: Maintenance 185 T4F Kubota User Manual

5.5 Maintenance every 50 hours• Inspect air filter elements and replace if neces-

sary.

• Check the engine fuel/water separator for water.

5.6 Maintenance every 100 hours• Clean the radiator and cooler exterior surfaces.

• Check the Engine Operator’s Manual for ser-vice requirements.

5.7 Maintenance every 250 hours• Check fan belt tension.

• Clean the radiator and cooler exterior surfaces. (Where dust and other atmospheric contami-nants are present, it might be necessary to clean these parts more frequently.)

• Check the Engine Operator’s Manual for ser-vice requirements.

• Change the engine oil and filter (see the Engine Operator’s Manual).

• Clean or replace the scavenge return line strainer.

• Change the air filter primary elements.

• Change the compressor fluid filter.

• Clean the return line orifice.

• Change the engine fuel/water separator filter. (If the filter tends to clog more often than what is expected, change the filter more frequently.)

• Change the engine fuel/water separator.

• Check the engine rpm idle speed. The idle speed should be at the specified minimum idle speed listed in Section 3.1: Specifications—49HP 185 Kubota on page 33.

5.8 Maintenance every 1500 hours• Change the compressor fluid with new Sullair

AWF® and replace the fluid filter element. (See

Section 5.9.2: Compressor fluid filter replace-ment.)

• Lubricate axle bearings on wheel-mounted units.

• Service the engine cooling system. (See Sec-tion 5.9.6: Cleaning the engine cooling sys-tem.)

5.9 Part replacement and adjustment procedures

5.9.1 Compressor fluid change procedure1. Run the compressor five to ten minutes to

warm the fluid.

2. Shut the compressor down and relieve all internal pressure.

3. Drain the fluid receiver tank by removing the plug, or opening the valve at the bottom of the receiver tank.

4. Change the compressor fluid and replace the fluid filter element (For element replacement see Section 5.9.2: Compressor fluid filter replacement.)

5. Fill the receiver tank with fluid in accordance with the specifications in Section 3.

5.9.2 Compressor fluid filter replacementSee Figure 5-1.

1. Remove the old fluid filter with a strap wrench.

2. Clean the gasket seating surface.

3. Apply a light coating of fluid to the new gas-ket.

4. Hand tighten the new fluid filter until the new gasket is seated.

5. Continue tightening the fluid filter by hand an additional ½ to ¾ turn.

6. Restart the compressor and check for leaks.

5.9.3 Air filter maintenanceRefer to Figure 5-2. Air filter maintenance should be per-formed as often as conditions require. If the filters are equipped with optional maintenance indicators, change the filters every time the indicators show a change is nec-essary.

5.9.3.1 Air filter replacement1. Loosen and remove the air filter and cover.

WARNING

Operating the compressor below its minimum specified idle speed will damage the compres-sor. Operating the compressor in this condition will cause coupling and/or compressor failure.

02250216-781 R0148 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 55: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 5: Maintenance

2. Remove the primary and optional safety ele-ments.

3. Clean the body, inside and out, with a damp cloth.

4. Reinstall (if clean) or replace the safety ele-ment if installed.

5. Replace the new primary filter element.

6. Reposition the cover and lock it into the position.

7. Reset the filter restriction indicator (if equipped).

Element inspection1. Insert a bright light source into the element

and look for any light leaks which indicate the presence of damage (holes, cracks, etc.)

2. Inspect all gaskets and gasket contact sur-faces of the housing and replace any dam-aged ones.

3. Store clean elements for later use in a clean container.

4. After installing the element, inspect and tighten all air inlet connections before operat-ing the compressor.

5.9.4 Separator element replacementRefer to Figure 5-3. When compressor fluid carryover is evident, after replacing or inspecting the fluid return line strainer and orifice, and the blowdown valve; and all are in satisfactory condition, the separator element must be replaced with kit number 250034-112 (element for air/fluid separator).

Figure 5-1: Compressor fluid filter

1. Fluid filter1

2. Compressor unit

3. Thermal valve manifold1Fluid filter replacement P/N: 250028-032

Figure 5-2: Air filter

1. Filter body

2. Filter cover

3. Primary element1

4. Safety element (optional)2

1Air filter primary element replacement P/N: 02250102-1582Air filter safety element replacement P/N: 02250102-160

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 49

Page 56: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

5: Maintenance 185 T4F Kubota User Manual

1. Disconnect all receiver tank cover piping connections to permit removal (return line, service line, etc.).

2. Remove the fluid return line from the fitting on the cover.

3. Remove the eight (8) cover bolts and wash-ers and lift the cover off the receiver tank.

4. Remove the separator element.

5. Scrape the old gasket material from the cover and the flange on the receiver tank. Do not allow the scrapings to fall into the tank.

6. Install the new element.

7. Replace the receiver tank cover and bolts. Lightly tighten all the bolts and then gradually tighten them alternating between bolts which are diagonally opposite each other. Torque the bolts to 60 ft-lbs (81 N•m).

8. Reconnect all piping. The fluid return line tube should extend to the bottom of the sep-arator element which will ensure proper return line flow.

9. Clean the fluid return line strainer and clear the orifice before starting the compressor.

10. After 24 hours of operation, tighten the receiver tank cover bolts to the value given in step 7.

5.9.5 Fuel/water separator maintenanceRefer to Figure 5-4 for all fuel/water separator mainte-nance procedures.

5.9.5.1 Draining water from the fuel/water separator

1. Shut down the compressor.

2. Open the compressor canopy.

3. Place a container for collecting the fluid under the drain.

4. Open the drain valve by turning it two turns to the left. Any water in the separator bowl will flow out through the drain.

5. When the fluid flowing from the drain changes from water to fuel, close the drain valve by turning the valve to the right until tight.

6. Close the compressor canopy.

WARNING

Fire hazard.

If the separator element’s staples are removed, a static electrical charge can create sparks that ignite the atomized oil in the compressed air stream.

Do not remove the staples from the separator element.

1

2

3

4

5

Figure 5-3: Air/fluid separator

1. Capscrew

2. Washer

3. Cover

4. Separator element (with gaskets)1

5. Receiver tank1Separator element replacement P/N: 250034-112

02250216-781 R0150 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 57: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 5: Maintenance

5.9.5.2 Replacing the fuel filter of the fuel/water separator

1. Shut down the compressor.

2. Open the compressor canopy.

3. Remove the separator bowl by turning it to the left.

4. Remove the old fuel filter by turning it to the left.

5. Install the new fuel filter by turning it to the right until tight.

6. Install the separator bowl by turning it to the right until tight.

7. Close the compressor canopy.

5.9.6 Cleaning the engine cooling system1. Shut down the compressor.

2. Allow the compressor to cool to ambient temperature.

3. Open the compressor canopy.

4. Disconnect the battery and tagout the connection.

5. Close the compressor canopy.

6. Remove the eight (8) recessed hex cap screws from the front louver.

7. Detach the front louver from the canopy.

8. Using a pressure washer, spray the cooler and radiator from side-to-side, starting at the top and moving down.

• Before using the pressure washer. consult the pressure washer’s owner’s manual.

9. Open the compressor canopy.

10. Using a pressure washer, clean the fan blades by blowing down through the fan guards.

11. Allow the compressor to dry completely.

12. Connect the battery and remove the tagout.

13. Close the compressor canopy.

14. Attach the front louver to the canopy.

15. Install the eight (8) recessed hex cap screws on the front louver.

NOTE

This machine is fitted with an electric fuel pump that primes the fuel system as soon as the power switch is turned on. A buzzing can be heard from the pump when it is on. When changing filters, this pump will prime the system with fuel.

Figure 5-4: Fuel/water separator

1. Separator head 4. Drain valve

2. Fuel filter 5. Drain

3. Separator bowl NOTICE

Stand directly in front of the compressor when spraying. Spraying from the sides can damage the cooler and radiator.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 51

Page 58: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

5: Maintenance 185 T4F Kubota User Manual

5.9.7 Procedure for setting speed & pressure controls on portable compressors equipped with poppet valves

Refer to Figure 5-5. Before adjusting the compressor’s control system, the rated full-load pressure and the high/low rpm settings must be determined. This information is provided in Section 3.1: Specifications—49HP 185 Kubota on page 33 or can be obtained by contacting a Sullair representative.

The following procedure applies to a compressor with full-load pressure rating of 100 psig (6.9 bar).

1. Start the compressor and allow the engine to warm-up to its normal operating temperature with the service valve closed.

2. Adjust the pressure regulator so that the compressor maintains 115 psig (8 bar).

3. Open the service valve to 100 psig (6.9 bar) (rated full load pressure) and recheck top engine speed and control response. Close the service valve and allow the compressor to cycle and re-check low engine speed (idle).

Figure 5-5: Control system adjustment

1. Receiver tank C. .25 OD black

2. Compressor unit D. .25 OD orange

3. Pressure regulator / blowdown manifold E. .38 yellow

A. .25 OD white F. .38 OD red

B. .38 OD blue G. .31 OD white (to fitting at unit air filter)

NOTICE

Operating the compressor below its minimum specified idle speed will damage the compres-sor. Operating the compressor in this condition will cause coupling and/or compressor failure.

02250216-781 R0152 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 59: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 5: Maintenance

5.9.8 Bearing lubricationRefer to Figure 5-6. Proper lubrication of the portable compressor’s bearing axle is critical to its proper function and reduction of wear on this part. Wheel bearings should be lubricated at least every 12 months, or more, to ensure proper performance and minimize wear. Use a wheel bearing grease that conforms to MILSPEC MIL-G-10924 or a high temperature one such as lithium complex NLGI consistency #2.

Axles with the E-Z Lube feature can be periodically lubri-cated without removing the hubs from the axle. This fea-ture consists of axle spindles that have been fitted with a grease zerk in their ends. When grease is pumped into the zerk, it is channeled to the inner bearing and then

flows back to the outer bearing, and then back out of the grease cap hold (see Figure 5-6).

1. Remove the rubber cap from the grease cap’s end.

2. Using a full charged grease gun, place the gun onto the grease zerk located on the end of the spindle. Make sure the nozzle is fully engaged on the fitting.

3. Pump grease into the zerk. The old grease will be displaced and flow out of the cap around the grease gun nozzle.

4. When the new grease starts flowing out of the cap, disengage the gun and wipe off any excess off the cap; and replace the rubber plug.

1

2

4

5

6

7

3

Figure 5-6: Typical E-Z lube axle

1. Rubber plug 5. Metal end cap

2. Outer bearing 6. Inner bearing

3. Grease flow 7. Spring-loaded double lip seal

4. Grease fitting

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 53

Page 60: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

5: Maintenance 185 T4F Kubota User Manual

5.10 TroubleshootingThe following troubleshooting chart is based upon data obtained from factory tests and information from the field. It lists symptoms, probable causes and remedies. This chart does not cover all possible malfunctions or cases of abnormal operation. Before undertaking repairs or replacement actions, analyze all of the available data.

Performing a detailed visual inspection in all cases can prevent additional damage or abnormal operation.

Always:

• Check for loose wiring or connections.

• Check for damaged piping.

• Check for heat damage to parts (electrical short circuits can cause heat damage) which can appear as discolorations or the presence of a burnt odor.

If the troubleshooting remedy does not work, or the mal-function is not covered in this troubleshooting chart, con-tact your nearest Sullair representative or Sullair for technical assistance.

Table 5-1: Troubleshooting guide

Symptom Probable cause Remedy

Low voltage or no voltage

Low voltage or battery discon-nected

Check battery cables and tighten if loose

Check ground wire for proper attachment to frame. Tighten if required.

Recharge or replace battery if required.

Blown fuse in wiring harnessRemove and inspect fuse. Replace if nec-essary.

Instrument panel connectors loose or disconnected.

Check instrument panel connectors and reattach if required

Check instrument panel wires for broken connections or corrosion. Clean and/or replace if damaged.

High compressor tem-perature

Compressor temperature switch is open

Check wiring connection to the switch and tighten if loose

Check switch continuity to ground and replace if necessary

Low receiver tank fluid level Add fluid to receiver tank as required

Loose or broken fan belt Tighten or replace belt

Cooling air flow is insufficient, dirty fluid cooler core

Clean core thoroughly and check for proper ventilation

Clogged compressor fluid filter Change fluid filter element

Faulty fluid thermostat Change fluid thermostat element

Plugged fluid cooler tube (internal) Replace cooler

02250216-781 R0154 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 61: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 5: Maintenance

High engine tempera-ture

Faulty engine temperature sensor Check wiring connection to the sensor

Cooling air flow is insufficientClean cooler and check for proper ventila-tion

Loose or broken fan belt Tighten or replace belt

Low engine coolantFill with proper water/glycol mixture as required

Faulty water pump Change pump

Defective engine thermostat Change thermostat element

Engine problems might be present Refer to the Engine Operator’s Manual

Engine will not start

Did not start compressor within the 30 seconds from turning the igni-tion switch to the ON position

After turning the ignition switch to the ON position, press the switch to the START position within 30 seconds

Low battery voltage

Check the battery cables and tighten if nec-essary

Recharge or replace battery if necessary

No fuel Refuel

Water or dirt in the fuel and/or filterDrain water from the fuel/water separators on the fuel filters. Siphon water from the fuel tank and clean the tank if necessary

Plugged air filter Clean and replace if necessary

Plugged fuel filter Replace the fuel filter

Engine problemsTurn the compressor off. See the Engine Operator’s Manual for shutdown codes.

Starter solenoid relay does not engage

Check wiring and tighten all connectors

Replace relay

Poor fuel delivery

No fuel Check fuel level and fill tank if empty

Air in fuel system

Check fuel system for air

Prime fuel system. See Figure 5-4 for loca-tion of the primer.

Refer to Engine Operator’s Manual

Compressor does not achieve full discharge pressure

Run/start switch not in run positionFor compressors with idle warm-up con-trols, switch toggle to RUN for full operation

Air demand is excessive Check service lines for leaks or open valves

Dirty air filterCheck the filter and change the element if required

Defective pressure regulatorCheck the diaphragm and replace with kit if necessary

Defective idle warm-up control Replace control

Table 5-1: Troubleshooting guide

Symptom Probable cause Remedy

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 55

Page 62: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

5: Maintenance 185 T4F Kubota User Manual

Improper unloading with an excessive pressure build-up causing the pressure relief valve to open

Pressure regulating valve is set too high

Readjust

Control system leak causing loss of pressure signal

Check control lines

Defective pressure regulating valve. Repair valve (kit available)

Inlet valve jammed Free or replace valve

Restriction in the control systemCheck all control lines and components. Ice and/or other contaminants could be the cause

Defective pressure relief valve opens when pressure is too low

Replace the pressure relief valve

Defective pressure regulatorCheck the diaphragm and replace with kit if necessary

Insufficient air delivery

Run/start switch not in run positionFor compressors with idle warm-up con-trols, switch toggle to RUN for full operation

Plugged air filter Replace

Defective idle warm-up control Replace control

Plugged air/fluid separatorReplace separator element and also change compressor fluid and fluid filter

Defective pressure regulator Adjust or repair

Engine speed too low Readjust engine speed

Excessive compres-sor fluid consumption

Clogged return line Clear orifice and return line strainer

Lubrication system leakCheck all pipes, connections and compo-nents

Separator element damaged or malfunctioning

Change separator element

Table 5-1: Troubleshooting guide

Symptom Probable cause Remedy

02250216-781 R0156 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 63: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Section 6

185 T4F Kubota User Manual 6: Noise Control

Noise Control

6.1 Noise emissions warrantySullair warrants to the ultimate purchaser and each sub-sequent purchaser that this air compressor was designed, built and equipped to conform at the time of sale to the first retail purchaser, with all applicable U.S. E.P.A. and/or any Federal, State or Local noise control regulations.

This warranty is not limited to any particular part, compo-nent, or system of the air compressor. Defects in the design, assembly, or in any part, component, or system of the compressor which, at the time of sale to the first retail purchaser, caused noise emissions to exceed Fed-eral standards are covered by this warranty for the life of the air compressor.

6.2 Tampering with the noise control system is prohibited

Federal Law prohibits the following acts or the causing thereof:

1. The removal or rendering inoperative by any persons, other than for purposes of mainte-nance, repair, or replacement, of any device or element of design incorporated into any new compressor for the purpose of noise

control prior to its sale or delivery to the ulti-mate purchaser or while it is in use.

2. The use of the compressor after such device or element of design has been removed or rendered inoperative by any person.

Among those acts included in the prohibition against tam-pering are the acts listed below:

1. Removal or rendering inoperative any of the following:

• Engine exhaust system or parts thereof

• Compressor air intake system or part thereof

• Enclosure of part thereof

2. Removal of any of the following:

• Vibration isolators

• Control silencer

• Floor panel

• Fan shroud

• Acoustical materials including fiberglass foam or foam tape

3. Operation with canopy doors open for any purpose other than starting, stopping, adjust-ment, repair, replacement of parts or mainte-nance.

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 57

Page 64: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

6: Noise Control 185 T4F Kubota User Manual

6.3 Noise emissions maintenance and maintenance record logThe following instructions and maintenance record log book, for the proper maintenance, use and repair of this com-pressor, is intended to prevent noise emission degradation.

Table 6-1: Annual muffler and exhaust system inspection

At least annually inspect muffler(s) and engine exhaust system to make sure all parts are securely mounted, that all joints and connections are tight, and that the muffler is in good condition. Do not operate compressor with defective exhaust system. Remove and replace any defective parts by ordering with part numbers indicated in the Parts List.

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Table 6-2: Annual air filter(s) and air inlet system inspection

In addition to the instructions in the Maintenance section of the Operator’s Manual, the air filter(s) and entire air inlet system should be inspected at least annually, to make sure all parts are securely mounted, that all joints and connections are tight, that there are no other leaks in the system, and that the filter element(s) are intact. Do not operate compressor with defective air inlet system. Remove and replace defective parts by ordering with part numbers indicated in the Parts List.

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

02250216-781 R0158 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 65: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

185 T4F Kubota User Manual 6: Noise Control

Table 6-3: Annual engine vibration mount inspection

At least annually inspect engine vibration mounts for security of attachment and to make sure the resilient parts are intact. Do not operate compressor with defective engine mounting system. Remove and replace defective parts by ordering with part numbers indicated in Parts List.

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Table 6-4: Annual frame, canopy and parts inspection

At least annually inspect frame, canopy and parts, for security of attachment. Make sure there are not any missing or deformed members, including all hinged doors, covers and their fastening devices. Do not operate compressor with defective frame, canopy and parts. Remove and replace defective parts by ordering with part numbers indicated in Parts List.

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

02250216-781 R01Subject to EAR, ECCN EAR99 and related export control restrictions. 59

Page 66: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

6: Noise Control 185 T4F Kubota User Manual

Table 6-5: Annual acoustical materials inspection

At least annually inspect all acoustical materials, if any, for security of attachment. Make sure that there is not any material missing or damaged (refer to Parts List). Clean or replace, if necessary. Do not operate compressor with defective acoustical material. Remove and replace defective parts by ordering with part numbers indicated in the Parts List.

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Table 6-6: Annual inspections for proper operation of all systems

In addition to other instructions in the Operator’s Manual, at least annually, operate compressor and inspect to make sure all systems are operating properly and that engine runs at rated speed and pressure. Do not operate malfunctioning or improperly adjusted compressor. Repair or adjust, per instructions in Operator’s Manual, as required.

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

Maintenance performed:

By:

Location:

Date:

02250216-781 R0160 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 67: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 68: 185 T4F Kubota User Manual en-US 02250216-781 R01 includes training on the function and installation of Sullair service parts, ... 1.8 Electrical shock ... tle) valve, when an air

Information and specifications are subject to change without prior notice.Subject to EAR, ECCN EAR99 and related export control restrictions.

Sullair, LLC3700 East Michigan BoulevardMichigan City, IN 46360 USA

www.sullair.com1-800-SULLAIR (USA only)1-219-879-5451 (non-USA)